For stylish home and office
CS385 / CS530B / CS730B / CS500B
CS385
CS530B
CS730B
* CS385B / CS530B / CS730B
CS385B / CS530B / CS730B
* Fully digitized microprocessor control
* Energy saving (UPS sleep mode )
* 50/60Hz frequency auto sensing
* Buzzer can be muted by pressing “ON/OFF” button
* Single PCB with reliable design
* Clear LED alarms
* Short circuit and overload protection
* Advanced battery management (ABM)
* Automatic diagnostics & battery check
* Surge protection of all outlets
* EMI/RFI noise filter
* Cold start (DC power on)
NEMA5-15 Only
Thailand,
Rear Panel
Model Name
CS 385B
CS 530B
CS 730B
OUTPUT
CS385B
UPS Capacity
No. of Sockets
385VA
530VA
730VA
NEMA 5-15R
UPS x 2, Bypass x 2
Breaker
Simulated sine wave at
Voltage
100V / 115V / 220V / 240V < +/- 5% AVR controlled by PWM
(on battery*)
Frequency (on battery)
50 or 60Hz +/- 0.3 Hz
< 10 milliseconds, including detection time
Battery
Transfer Time
Backup
INPUT
Voltage
100V +/- 20%, 110V +/- 25%
220V / 230V / 240V, 170V~280 at line input
50 or 60 Hz +/- 10% (auto sensing)
(single phase)
Bypass
Frequency
PROTECTION
Unit Input
Circuit breaker for overload & short circuit protection
UPS Automatic shutdown if overload exceeds 105% of
Overload Protection
nominal at 20 seconds, 120% at 10 seconds, 130% at 3 seconds
UPS output cut off immediately
Short Circuit
Spike Protection
460 joules, 2ms
CS530B / CS730B
BATTERY
Type
Sealed, maintenance-free lead acid batteries with 3-5 years
typical life time
Breaker
Typical Recharge Time
6 hours
(to 90% of full capacity)
Back-up Time
Protection
PC with
15” LCD
8 - 12 minutes
15 - 18 minutes
Automatic self- test, Over discharge protection, short circuit
protection by fuse
Bypass
Battery
Backup
PHYSICAL
2.6 (5.72)
Net Weight kg (lbs)
Dimension WxDxH
INTERFACE
1.6 (3.52)
95 x 95 x 158 mm
2.6 (5.72)
95 x 138 x 158 mm
Sends battery low & power failure signals, and receives shutdown signal from computer
Detects power failure battery low, Schedules UPS ON / OFF, displays AC input / output power status
Dry Contact (option)
USB (option)
ALARM
Battery Backup
Short beeping sound every 4 seconds
(Buzzer can be muted by pressing main switch button)
Rapid beeping sound every seconds
Battery Low
UPS Works at Full Load
Overload
Long continuous beeping sound every 4 second
Continuous beeping sound
ENVIRONMENT
Ambient Operation
3,500 meters max elevation, 0-95% humidity
(No-condensing water),0-40 deg C
<40dBA (1 meter form surface)
Audible Noise
* See VS1000C on page 6