INSTALLATION INSTRUCTIONS  
READ & SAVE THESE INSTRUCTIONS!  
Belt Driven Whole House Ventilator  
MODELS: WHV-30BD & WHV-36BD  
For use with louver models: WHL-30 & WHL-36  
IMPORTANT SAFETY INSTRUCTIONS  
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC  
SHOCK, OR INJURY TO PERSONS, OBSERVE THE  
FOLLOWING:  
(A) Use this unit only in the manner intended by the  
manufacturer. If you have questions, contact the  
manufacturer.  
(B) Before servicing or cleaning unit, switch power off at  
service panel and lock service panel to prevent power  
from being switched on accidentally.  
When the service disconnecting means cannot be  
locked, securely fasten a prominent warning device,  
such as a tag, to the service panel.  
CAUTION: For general ventilating use only. Do not use to  
exhaust hazardous or explosive materials and vapors.  
CAUTION: This unit has an unguarded impeller. Do not use  
in locations readily accessible to people or animals.  
FIGURE 1  
INSTALLATION INSTRUCTIONS  
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC  
SHOCK, OR INJURY TO PERSONS, OBSERVE THE  
FOLLOWING:  
INSTALLATION  
(A) Installation work and electrical wiring must be done by  
qualified person(s) in accordance with all applicable  
codes and standards, including fire-rated construction.  
(B) Sufficient air is needed for proper combustion and  
exhausting of gases through the flue (chimney) of fuel  
burning equipment to prevent back drafting. Follow  
the heating equipment manufacturer’s guideline and  
safety standards such as those published by the  
National Fire Protection Association (NFPA), and the  
American Society for Heating, Refrigeration, and Air  
Conditioning Engineers (ASHRAE), and the local  
code authorities.  
(C) When cutting or drilling into wall or ceiling, do not  
damage electrical wiring and other hidden utilities.  
(D) Ducted fans must always be vented to the outdoors.  
(E) If this unit is to be installed over a tub or shower, it  
must be marked as appropriate for the application.  
(F) NEVER place a switch where it can be reached from  
a tub or shower.  
Refer to Figure 1.  
1. Decide upon desired location in central hallway.  
2. Remove attic insulation from area where the Whole-House  
Ventilator will be installed. Make sure the attic floor is free  
of electrical wiring or plumbing pipes. There should be  
approximately 36" of clearance between the top of ceiling  
joists and the roof. This will prevent back pressure which  
can reduce efficiency and increase noise level.  
3. Using the template provided on the louver carton,  
determine the desired location and orientation of the  
louver. Drive a small nail up through the ceiling at one  
corner of the template.  
4. Locate nail from above. Using this point as a reference,  
layout louver cutout.  
WHL-36  
WHL-30  
3414" x 36"  
3414" X 29"  
WARNING: To reduce the risk of fire or shock, do not use  
with solid state speed controls. This fan is intended for  
installation facing an unoccupied space only.  
IMPORTANT: Read each step completely before beginning  
your installation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPRING MOUNTING  
NAIL  
SPRING (SPACE 12" FROM WOOD)  
(INSTALL SPRING IN CONNECTING  
BAR AS SHOWN BELOW)  
CONNECTING BAR  
SHUTTER FRAME  
FIGURE 6  
WIRING  
CAUTION: Electrical connections and all wiring should be  
in accordance with the National Electrical Code and all local  
codes that may apply.  
WARNING: To avoid possible injury or electrical shock,  
disconnect power at fuse or circuit breaker box before  
attempting to wire this fan.  
• Incorrect wiring may cause motor failure and possible fire.  
If necessary, engage the services of a qualified electrician  
to wire fan.  
Connect electrical wiring from wall switch to motor leads  
in motor junction box. If two speed switch is not used, make  
sure red lead of motor (low speed) is capped with a wire nut.  
IMPORTANT: Be sure to ground fan by connecting ground  
wire to ground screw of junction box.  
OPERATING FAN  
FIGURE 7  
Before turning fan on, open windows and interior doors to  
insure proper air intake through rooms to be ventilated. If you  
have a fireplace, be certain the flue damper is closed to  
prevent chimney dirt and soot from being brought into the  
house by the fan. Always start fan on high speed and allow  
louver to open fully before switching to low speed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
One Year Limited Warranty  
WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period  
of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED  
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.  
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES  
FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident,  
improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.  
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty  
lasts, so the above limitation may not apply to you.  
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS  
WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH  
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may  
not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.  
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model  
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present  
evidence of the original purchase date.  
Date of Installation  
Builder or Installer  
Model No. and Product Description  
IF YOU NEED ASSISTANCE OR SERVICE:  
For the location of your nearest NuTone Independent Authorized Service Center:  
Residents of the contiguous United States Dial Free 1-800-543-8687  
Please be prepared to provide:  
Product model number • Date and Proof of purchase • The nature of the difficulty  
Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599.  
Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.  
Rev. 03/2001  
Product specifications subject to change without notice.  
4820 Red Bank Road, Cincinnati, Ohio 45227  
Printed in U.S.A., Rev. 3/02, Part No. k3585  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Moulinex Kitchen Utensil Meat Mincer User Manual
NEC CRT Television NLT 26HD1 User Manual
NeumannBerlin Microphone KM 74 User Manual
Nikon Camera Lens ED180600MM User Manual
NordicTrack Home Gym NTL23920 User Manual
Ocean Kayak Boat Kayak User Manual
One for All Universal Remote 5 User Manual
Optimus Portable CD Player CD 3520 User Manual
Ozark Trail Network Card 842 A100 W User Manual
Panasonic Fax Machine KX PW301DL User Manual