READ & SAVE THESE INSTRUCTIONS!
INSTALLATION INSTRUCTIONS
Indoor Remote Control
MODEL: ICA-441WH
• For use with IMA4406, IM4406, IMA4006 or IM4006
Series Systems to operate the ISA-78, IS-82, IS-76,
IS-903, IS-905 and IS-908 Speakers.
• IMPORTANT: Speakers that do not have built-in controls
require a separate remote control. Model ICA-441WH is
designed for indoor use only.
ROUGH-IN FRAME MOUNTING
1. The remote control may be recess-mounted to the Model
IR-91 Rough-In Frame.
2. The wiring should be installed when the system is
roughed-in.
3. The remote controls require NuTone Model IW-6 3-twisted
pair (6 wire) cable from the master station to the remote
control location. NuTone Model IW-2 2-conductor twisted
pair (22/2) cable is used from the remote control to the
speaker. See instructions packaged with the rough-in
frames.
ORANGE
RED
WIRING CONNECTIONS
1. Refer to Figure 1. As illustrated, connect wires from the
master unit to the six (6) screw terminals. Red wire to the
terminal marked red, red/white wire to the terminal marked
red/white, etc.
BLACK
BLACK/WHITE
ORANGE/WHITE
RED/WHITE
FIGURE 1
3. Refer to Figure 2. Connect IW-2 cable from the speaker to
the remote control's two (2) speaker wires.
IMPORTANT – WHEN NUTONE MODEL IW-6R
WIRING IS USED:
ICA-441WH
CIRCUIT
BOARD
CONNECT TO SCREWS ON PRINTED
CIRCUIT BOARD MARKED:
1
2
3
4
5
6
ORN
BLK
BLK/WHITE
ORN/WHITE
RED
IW-2 CABLE
TO SPEAKER
RED/WHITE
FIGURE 2
BLUE STRIPE