Nortel Networks Power Supply NN46200 310 User Manual

Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
Release: 4.1  
Document Revision: 01.01  
NN46200-310  
(324629-A Rev 01)  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
5
.
Regulatory information and safety  
precautions  
International regulatory statements of conformity  
This is to certify that the Nortel Networks 8300 series chassis and  
components installed within the chassis were evaluated to the international  
regulatory standards for electromagnetic compliance (EMC) and safety and  
were found to have met the requirements for the following international  
standards:  
EMC—Electromagnetic Emissions—CISPR 22, Class A  
EMC—Electromagnetic Immunity—CISPR 24  
Electrical Safety—IEC 60950, with CB member national deviations  
Further, the equipment has been certified as compliant with the national  
standards as detailed in the following sections.  
National electromagnetic compliance (EMC) statements of  
compliance  
FCC statement (USA only)  
This equipment has been tested and found to comply with the limits for a  
Class A digital device, pursuant to Part 15 of the Federal Communications  
Commission (FCC) rules. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is operated  
in a commercial environment. This equipment generates, uses, and can  
radiate radio frequency energy. If it is not installed and used in accordance  
with the instruction manual, it may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is likely  
to cause harmful interference, in which case users will be required to take  
whatever measures may be necessary to correct the interference at their  
own expense.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
6
Regulatory information and safety precautions  
ICES statement (Canada only)  
Canadian Department of Communications Radio Interference  
Regulations  
This digital apparatus (8300 series chassis and installed components)  
does not exceed the Class A limits for radio-noise emissions from  
digital apparatus as set out in the Radio Interference Regulations of the  
Canadian Department of Communications.  
Règlement sur le brouillage radioélectrique du ministère des  
Communications  
Cet appareil numérique (8300 series chassis) respecte les limites de bruits  
radioélectriques visant les appareils numériques de classe A prescrites  
dans le Règlement sur le brouillage radioélectrique du ministère des  
Communications du Canada.  
CE marking statement (Europe only)  
EN 55 022 statements  
This is to certify that the Nortel Networks 8300 series chassis and  
components installed within the chassis are shielded against the  
generation of radio interference in accordance with the application of  
Council Directive 2004/108/EC. Conformity is declared by the application  
of EN 55 022 Class A (CISPR 22).  
ATTENTION  
This is a Class A product. In a domestic environment, this product may cause  
radio interference, in which case, the user may be required to take appropriate  
measures.  
Achtung  
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können  
bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in welchen Fällen der  
Benutzer für entsprechende Gegenmaβnahmen verantwortlich ist.  
Attention:  
Ceci est un produit de Classe A. Dans un environnement domestique, ce  
produit risque de créer des interférences radioélectriques, il appartiendra alors à  
l’utilisateur de prendre les mesures spécifiques appropriées.  
EN 55 024 statement  
This is to certify that the Nortel Networks 8300 series chassis is shielded  
against the susceptibility to radio interference in accordance with the  
application of Council Directive 2004/108/EC. Conformity is declared by  
the application of EN 55 024 (CISPR 24).  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
National electromagnetic compliance (EMC) statements of compliance  
7
EN 300386 statement  
The Ethernet Routing Switch 8300 series chassis complies with the  
requirements of EN 300386 V1.3.3 for emissions and for immunity for a  
Class A device intended for use in either Telecommunications centre or  
locations other than telecommunications centres given the performance  
criteria as specified by the manufacturer.  
EC Declaration of Conformity  
This product conforms to the provisions of the R&TTE Directive  
1999/5/EC.  
European Union and European Free Trade Association (EFTA) notice  
All products labeled with the CE marking comply with R&TTE Directive  
(1999/5/EEC) which includes the Electromagnetic Compliance (EMC)  
Directive (2004/108/EC) and the Low Voltage Directive (2006/95/EC)  
issued by the Commission of the European Community.  
Compliance with these directives implies conformity to the following  
European Norms (ENs). The equivalent international standards are listed  
in parenthesis.  
EN 55022 (CISPR 22)–Electromagnetic Interference  
EN 55024 (IEC 61000-4-2, -3, -4, -5, -6, -8, -11)–Electromagnetic  
Immunity  
EN 61000-3-2 (IEC 610000-3-2)–Power Line Harmonics  
EN 61000-3-3 (IEC 610000-3-3)–Power Line Flicker  
VCCI statement (Japan/Nippon only)  
This is a Class A product based on the standard of the Voluntary Control  
Council for Interference (VCCI) for information technology equipment.  
If this equipment is used in a domestic environment, radio disturbance  
may arise. When such trouble occurs, the user may be required to take  
corrective actions.  
BSMI statement for 8310 and 8306 chassis (Taiwan only)  
This is a Class A product based on the standard of the Bureau of  
Standards, Metrology and Inspection (BSMI) CNS 13438, Class A.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
8
Regulatory information and safety precautions  
MIC notice for 8310 and 8306 chassis (Republic of Korea only)  
This device has been approved for use in Business applications only per  
the Class A requirements of the Republic of Korea Ministry of Information  
and Communications (MIC). This device may not be sold for use in a  
nonbusiness application.  
National safety statements of compliance  
CE marking statement (Europe only)  
EN 60 950 statement  
This is to certify that the Nortel Networks 8300 series chassis and  
components installed within the chassis are in compliance with the  
requirements of EN 60 950 in accordance with the Low Voltage Directive.  
Additional national differences for all European Union countries have been  
evaluated for compliance. Some components installed within the 8300  
series chassis may use a nickel-metal hydride (NiMH) and/or lithium-ion  
battery. The NiMH and lithium-ion batteries are long-life batteries, and it is  
very possible that you will never need to replace them. However, should  
you need to replace them, refer to the individual component manual for  
directions on replacement and disposal of the battery.  
NOM statement 8310 and 8306 chassis (Mexico only)  
The following information is provided on the devices described in this  
document in compliance with the safety requirements of the Norma Oficial  
Méxicana (NOM):  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
National safety statements of compliance  
9
Exporter:  
Importer:  
Nortel Networks, Inc.  
4655 Great America Parkway  
Santa Clara CA 95054 USA  
Nortel Networks de México, S.A. de C.V.  
Avenida Insurgentes Sur #1605  
Piso 30, Oficina  
Col. San Jose Insurgentes  
Deleg-Benito Juarez  
México D.F. 03900  
52 5 480 2100  
Tel:  
52 5 480 2199  
Fax:  
Input:  
Model 8005DC:  
48-60 VDC, 29-23 A  
single supply, single supply + one redundant  
supply, two supplies, or two + one redundant supply  
configuration  
Model 8005DI DC:  
48-60 VDC, 42-34 A  
single supply, single supply + one redundant  
supply, two supplies, or two + one redundant supply  
configuration  
Información NOM (unicamente para México)  
La información siguiente se proporciona en el dispositivo o en los  
dispositivos descritos en este documento, en cumplimiento con los  
requisitos de la Norma Oficial Méxicana (NOM):  
Exportador:  
Nortel Networks, Inc.  
4655 Great America Parkway  
Santa Clara, CA 95054 USA  
Importador:  
Nortel Networks de México, S.A. de C.V.  
Avenida Insurgentes Sur #1605  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
10 Regulatory information and safety precautions  
Piso 30, Oficina  
Col. San Jose Insurgentes  
Deleg-Benito Juarez  
México D.F. 03900  
52 5 480 2100  
52 5 480 2199  
Model 8005DC:  
-48 VCD, 29 A  
Tel:  
Fax:  
Embarcar a:  
una fuente, una fuente + configuraciones de una fuente  
redundante, dos fuentes o dos + configuraciones de  
una fuente redundante  
Model 8005DI DC:  
-48 VCD, 42 A  
una fuente, una fuente + configuraciones de una fuente  
redundante, dos fuentes o dos + configuraciones de  
una fuente redundante  
Denan statement (Japan/Nippon only)  
Safety messages  
This section describes the different precautionary notices used in this  
document. This section also contains precautionary notices that you must  
read for safe operation of the Nortel Ethernet Routing Switch 8300.  
Notices  
Notice paragraphs alert you about issues that require your attention. The  
following sections describe the types of notices.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
Safety messages 11  
Attention notice  
ATTENTION  
An attention notice provides important information regarding the installation and  
operation of Nortel products.  
Caution ESD notice  
CAUTION  
ESD  
ESD notices provide information about how to avoid discharge  
of static electricity and subsequent damage to Nortel products.  
CAUTION  
ESD (décharge électrostatique)  
La mention ESD fournit des informations sur les moyens de  
prévenir une décharge électrostatique et d’éviter d’endommager  
les produits Nortel.  
CAUTION  
ACHTUNG ESD  
ESD-Hinweise bieten Information dazu, wie man die  
Entladung von statischer Elektrizität und Folgeschäden an  
Nortel-Produkten verhindert.  
CAUTION  
PRECAUCIÓN ESD (Descarga electrostática)  
El aviso de ESD brinda información acerca de cómo evitar  
una descarga de electricidad estática y el daño posterior a los  
productos Nortel.  
CAUTION  
CUIDADO ESD  
Os avisos do ESD oferecem informações sobre como evitar  
descarga de eletricidade estática e os conseqüentes danos aos  
produtos da Nortel.  
CAUTION  
ATTENZIONE ESD  
Le indicazioni ESD forniscono informazioni per evitare scariche  
di elettricità statica e i danni correlati per i prodotti Nortel.  
Caution notice  
CAUTION  
Caution notices provide information about how to avoid possible  
service disruption or damage to Nortel products.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
12 Regulatory information and safety precautions  
CAUTION  
ATTENTION  
La mention Attention fournit des informations sur les moyens  
de prévenir une perturbation possible du service et d’éviter  
d’endommager les produits Nortel.  
CAUTION  
ACHTUNG  
Achtungshinweise bieten Informationen dazu, wie man mögliche  
Dienstunterbrechungen oder Schäden an Nortel-Produkten  
verhindert.  
CAUTION  
PRECAUCIÓN  
Los avisos de Precaución brindan información acerca de  
cómo evitar posibles interrupciones del servicio o el daño a los  
productos Nortel.  
CAUTION  
CUIDADO  
Os avisos de cuidado oferecem informações sobre como evitar  
possíveis interrupções do serviço ou danos aos produtos da  
Nortel.  
CAUTION  
ATTENZIONE  
Le indicazioni di attenzione forniscono informazioni per evitare  
possibili interruzioni del servizio o danni ai prodotti Nortel.  
Warning notice  
WARNING  
Warning notices provide information about how to avoid  
personal injury when working with Nortel products.  
WARNING  
AVERTISSEMENT  
La mention Avertissement fournit des informations sur  
les moyens de prévenir les risques de blessure lors de la  
manipulation de produits Nortel.  
WARNING  
WARNUNG  
Warnhinweise bieten Informationen dazu, wie man  
Personenschäden bei der Arbeit mit Nortel-Produkten  
verhindert.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Safety messages 13  
WARNING  
ADVERTENCIA  
Los avisos de Advertencia brindan información acerca de cómo  
prevenir las lesiones a personas al trabajar con productos  
Nortel.  
WARNING  
AVISO  
Os avisos oferecem informações sobre como evitar ferimentos  
ao trabalhar com os produtos da Nortel.  
WARNING  
AVVISO  
Le indicazioni di avviso forniscono informazioni per evitare danni  
alle persone durante l’utilizzo dei prodotti Nortel.  
Danger High Voltage notice  
DANGER  
Danger—High Voltage notices provide information about how to  
avoid a situation or condition that can cause serious personal  
injury or death from high voltage or electric shock.  
DANGER  
La mention Danger—Tension élevée fournit des informations  
sur les moyens de prévenir une situation ou une condition qui  
pourrait entraîner un risque de blessure grave ou mortelle à la  
suite d’une tension élevée ou d’un choc électrique.  
DANGER  
GEFAHR  
Hinweise mit Vorsicht – Hochspannung“ bieten Informationen  
dazu, wie man Situationen oder Umstände verhindert, die zu  
schweren Personenschäden oder Tod durch Hochspannung  
oder Stromschlag führen können.  
DANGER  
PELIGRO  
Los avisos de Peligro-Alto voltaje brindan información acerca  
de cómo evitar una situación o condición que cause graves  
lesiones a personas o la muerte, a causa de una electrocución  
o de una descarga de alto voltaje.  
DANGER  
PERIGO  
Avisos de Perigo—Alta Tensão oferecem informações sobre  
como evitar uma situação ou condição que possa causar graves  
ferimentos ou morte devido a alta tensão ou choques elétricos.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
14 Regulatory information and safety precautions  
DANGER  
PERICOLO  
Le indicazioni Pericolo—Alta tensione forniscono informazioni  
per evitare situazioni o condizioni che potrebbero causare gravi  
danni alle persone o il decesso a causa dell’alta tensione o di  
scosse elettriche.  
Danger notice  
DANGER  
Danger notices provide information about how to avoid a  
situation or condition that can cause serious personal injury or  
death.  
DANGER  
La mention Danger fournit des informations sur les moyens de  
prévenir une situation ou une condition qui pourrait entraîner un  
risque de blessure grave ou mortelle.  
DANGER  
GEFAHR  
Gefahrenhinweise stellen Informationen darüber bereit, wie  
man Situationen oder Umständen verhindert, die zu schweren  
Personenschäden oder Tod führen können.  
DANGER  
PELIGRO  
Los avisos de Peligro brindan información acerca de cómo  
evitar una situación o condición que pueda causar lesiones  
personales graves o la muerte.  
DANGER  
PERIGO  
Avisos de perigo oferecem informações sobre como evitar uma  
situação ou condição que possa causar graves ferimentos ou  
morte.  
DANGER  
PERICOLO  
Le indicazioni di pericolo forniscono informazioni per evitare  
situazioni o condizioni che potrebbero causare gravi danni alle  
persone o il decesso.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
15  
.
Software license  
This section contains the Nortel Networks software license.  
Nortel Networks Inc. software license agreement  
This Software License Agreement ("License Agreement") is between  
you, the end-user ("Customer") and Nortel Networks Corporation and  
its subsidiaries and affiliates ("Nortel Networks"). PLEASE READ THE  
FOLLOWING CAREFULLY. YOU MUST ACCEPT THESE LICENSE  
TERMS IN ORDER TO DOWNLOAD AND/OR USE THE SOFTWARE.  
USE OF THE SOFTWARE CONSTITUTES YOUR ACCEPTANCE OF  
THIS LICENSE AGREEMENT. If you do not accept these terms and  
conditions, return the Software, unused and in the original shipping  
container, within 30 days of purchase to obtain a credit for the full  
purchase price.  
"Software" is owned or licensed by Nortel Networks, its parent or one of  
its subsidiaries or affiliates, and is copyrighted and licensed, not sold.  
Software consists of machine-readable instructions, its components, data,  
audio-visual content (such as images, text, recordings or pictures) and  
related licensed materials including all whole or partial copies. Nortel  
Networks grants you a license to use the Software only in the country  
where you acquired the Software. You obtain no rights other than those  
granted to you under this License Agreement. You are responsible for the  
selection of the Software and for the installation of, use of, and results  
obtained from the Software.  
1. Licensed Use of Software. Nortel Networks grants Customer a  
nonexclusive license to use a copy of the Software on only one machine  
at any one time or to the extent of the activation or authorized usage level,  
whichever is applicable. To the extent Software is furnished for use with  
designated hardware or Customer furnished equipment ("CFE"), Customer  
is granted a nonexclusive license to use Software only on such hardware  
or CFE, as applicable. Software contains trade secrets and Customer  
agrees to treat Software as confidential information using the same care  
and discretion Customer uses with its own similar information that it does  
not wish to disclose, publish or disseminate. Customer will ensure that  
anyone who uses the Software does so only in compliance with the terms  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
16 Software license  
of this Agreement. Customer shall not a) use, copy, modify, transfer  
or distribute the Software except as expressly authorized; b) reverse  
assemble, reverse compile, reverse engineer or otherwise translate the  
Software; c) create derivative works or modifications unless expressly  
authorized; or d) sublicense, rent or lease the Software. Licensors of  
intellectual property to Nortel Networks are beneficiaries of this provision.  
Upon termination or breach of the license by Customer or in the event  
designated hardware or CFE is no longer in use, Customer will promptly  
return the Software to Nortel Networks or certify its destruction. Nortel  
Networks may audit by remote polling or other reasonable means to  
determine Customer’s Software activation or usage levels. If suppliers of  
third party software included in Software require Nortel Networks to include  
additional or different terms, Customer agrees to abide by such terms  
provided by Nortel Networks with respect to such third party software.  
2. Warranty. Except as may be otherwise expressly agreed to in  
writing between Nortel Networks and Customer, Software is provided  
"AS IS" without any warranties (conditions) of any kind. NORTEL  
NETWORKS DISCLAIMS ALL WARRANTIES (CONDITIONS) FOR THE  
SOFTWARE, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT  
LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE AND ANY WARRANTY OF  
NON-INFRINGEMENT. Nortel Networks is not obligated to provide support  
of any kind for the Software. Some jurisdictions do not allow exclusion  
of implied warranties, and, in such event, the above exclusions may not  
apply.  
3. Limitation of Remedies. IN NO EVENT SHALL NORTEL  
NETWORKS OR ITS AGENTS OR SUPPLIERS BE LIABLE FOR ANY  
OF THE FOLLOWING: a) DAMAGES BASED ON ANY THIRD PARTY  
CLAIM; b) LOSS OF, OR DAMAGE TO, CUSTOMER’S RECORDS,  
FILES OR DATA; OR c) DIRECT, INDIRECT, SPECIAL, INCIDENTAL,  
PUNITIVE, OR CONSEQUENTIAL DAMAGES (INCLUDING LOST  
PROFITS OR SAVINGS), WHETHER IN CONTRACT, TORT OR  
OTHERWISE (INCLUDING NEGLIGENCE) ARISING OUT OF  
YOUR USE OF THE SOFTWARE, EVEN IF NORTEL NETWORKS,  
ITS AGENTS OR SUPPLIERS HAVE BEEN ADVISED OF THEIR  
POSSIBILITY. The forgoing limitations of remedies also apply to any  
developer and/or supplier of the Software. Such developer and/or supplier  
is an intended beneficiary of this Section. Some jurisdictions do not allow  
these limitations or exclusions and, in such event, they may not apply.  
4. General  
1. If Customer is the United States Government, the following paragraph  
shall apply: All Nortel Networks Software available under this License  
Agreement is commercial computer software and commercial computer  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Nortel Networks Inc. software license agreement 17  
software documentation and, in the event Software is licensed for  
or on behalf of the United States Government, the respective rights  
to the software and software documentation are governed by Nortel  
Networks standard commercial license in accordance with U.S. Federal  
Regulations at 48 C.F.R. Sections 12.212 (for non-DoD entities) and  
48 C.F.R. 227.7202 (for DoD entities).  
2. Customer may terminate the license at any time. Nortel Networks  
may terminate the license if Customer fails to comply with the terms  
and conditions of this license. In either event, upon termination,  
Customer must either return the Software to Nortel Networks or certify  
its destruction.  
3. Customer is responsible for payment of any taxes, including personal  
property taxes, resulting from Customer’s use of the Software.  
Customer agrees to comply with all applicable laws including all  
applicable export and import laws and regulations.  
4. Neither party may bring an action, regardless of form, more than two  
years after the cause of the action arose.  
5. The terms and conditions of this License Agreement form the complete  
and exclusive agreement between Customer and Nortel Networks.  
6. This License Agreement is governed by the laws of the country in  
which Customer acquires the Software. If the Software is acquired in  
the United States, then this License Agreement is governed by the  
laws of the state of New York.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
18 Software license  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
19  
.
New in this Release  
The following sections detail what’s new in Nortel Ethernet Routing Switch  
8300 Installation — DC Power Supply, NN46200-310 for Release 4.1:  
Features  
The 8005DC and 8005DI DC is a new feature for the Ethernet Routing  
Switch 8300.  
Other changes  
See the following section for information about changes that are not  
feature-related:  
Document changes  
This document is modified to meet Nortel Customer Documentation  
Standards. For more information about these standards, see Nortel  
Ethernet Routing Switch 8300 Documentation Roadmap, NN46200-101.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
       
20 New in this Release  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
21  
.
Introduction  
This guide provides information about the 8005 Dual Input (DI) DC and  
8005DC power supplies used in the Ethernet Routing Switch 8300.  
The guide also includes instructions for adding and replacing this DC  
power supply in the following Ethernet Routing Switch 8300 chassis  
models:  
8306 Chassis  
8310 Chassis  
ATTENTION  
This guide is intended for qualified service personnel with appropriate technical  
training and experience. The service personnel also must be aware of the  
hazards involved in installing and replacing customer-replaceable units.  
CAUTION  
This device is a Class A product. Operation of this equipment  
in a residential area is likely to cause harmful interference, in  
which case users are required to take appropriate measures  
necessary to correct the interference at their own expense.  
For the minimum Ethernet Routing Switch 8300 software version required  
to support the hardware, see Nortel Ethernet Routing Switch 8300  
Administration, NN46200-604.  
Task and estimated time  
The following table lists the estimated time to install a DC power supply for  
the Ethernet Routing Switch 8300.  
The estimated installation time can range from 15 to 50 minutes. The  
installation time depends on the chassis model and the number of power  
supplies you are installing.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
22 Introduction  
Table 1  
Task and estimated time  
Task  
Estimated Time  
Preparing cable for installation  
Removing the power filler panel  
Installing the DC power supply  
5 minutes for each power supply  
1 minute for each power supply  
2 minutes for each power supply  
Removing the DC power supply cover 1 minute for each power supply  
Cabling the DC power supply using  
washers and lugs  
5 minutes for each power supply  
Replacing the DC power supply cover  
1 minute for each power supply  
Navigation  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
23  
.
DC power supply fundamentals  
This section provides the basic information about the Ethernet Routing  
Switch 8300 DC power supplies.  
Navigation  
Power supply LED  
The following table describes the power supply Light Emitting Diode (LED)  
on the DC power supply.  
Table 2  
Power supply LED  
State  
Description  
Off  
No output is present  
On (green)  
Power supply output is normal  
DC power supply accessories  
The Ethernet Routing Switch 8300 chassis ships with no installed power  
supplies. Install the first power supply in the left-most bay. Power supply  
bays are numbered 1, 2, and 3 from left to right as viewed from the front  
of the chassis for the 8306 and 8310. For instructions to install the power  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
       
24 DC power supply fundamentals  
In addition to the DC power supply and the installation guide, your DC  
power supply shipment contains several hardware accessories. Verify that  
the items in the shipping container match those on the shipment packing  
list.  
Use the following table as a checklist to verify the contents of the DC  
power supply shipping container.  
Table 3  
DC power supply shipping accessories  
Check  
Accessory  
Purpose  
3 two-hole crimp  
lug terminals with  
attached tubing  
Connect the  
positive and  
negative power  
inputs.  
6 nuts  
Connect all leads.  
Connect all leads.  
6 lock washers  
2 washers  
Connect the  
ground stud.  
Ethernet Routing Switch 8300 series chassis  
This section describes the Ethernet Routing Switch 8300 series chassis  
DC power supplies.  
The 8306 and 8310 chassis each have three power supply bays in which  
you can install either the 8005DC or the 8005DI DC power supply.  
If the total power provided by the power supplies falls below the switch  
requirement, the polling software displays the following message on  
the console: "chCheckPowerUsage: One or more cards running low on  
power."  
To display the total power the switch uses and the total power the power  
supplies provide, see Nortel Ethernet Routing Switch 8300 Performance  
Management, NN46200-705.  
8005DI DC power supply  
Each 8005DI DC power supply provides 1462 W of power to the switch.  
The 8005DI DC power supply does not provide any power for Power over  
Ethernet (PoE).  
The following figure shows the 8005DI DC power supply used in the 8306  
and 8310 chassis.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
8005DC power supply 25  
Minimum number of 8005DI DC power supplies to install  
To configure an Ethernet Routing Switch 8300 system, consider the total  
power consumption to ensure proper system performance.  
The total input power consumption of the components (modules and fan  
trays) must not exceed the 8005DI DC power supply rating.  
To determine the minimum number of power supplies to install for the  
Ethernet Routing Switch 8300 system, see “Determining the minimum  
8005DC power supply  
Each 8005DC power supply provides 1462 W of power to the switch.  
The 8005DC power supply does not provide any power for Power over  
Ethernet (PoE).  
The following figure shows the 8005DC power supply used in the 8306  
and 8310 chassis.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
26 DC power supply fundamentals  
Minimum number of 8005DC power supplies to install  
To configure an Ethernet Routing Switch 8300 system, consider the total  
power consumption to ensure proper system performance.  
The total input power consumption of the components (modules and fan  
trays or cooling modules) must not exceed the 8005DC power supply  
rating.  
To determine the minimum number of power supplies to install for the  
Ethernet Routing Switch 8300 system, see “Determining the minimum  
Redundant power configuration  
If a chassis has a redundant power configuration and one power supply  
fails, the chassis continues to operate with no interruption of service.  
The chassis continues to supply the same module output power with the  
remaining power supplies. A trap and syslog message indicates that the  
configuration is nonredundant. Nortel recommends that you operate the  
Ethernet Routing Switch 8300 system in a redundant configuration at all  
times to ensure maximum network performance.  
ATTENTION  
A redundant power supply ensures that the system does not fail if a single  
power supply fails.  
If a chassis has the minimum power supply configuration and one power  
supply fails, the system loses power and network connectivity.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
27  
.
DC power supply installation  
This chapter provides instructions to install the DC power supply in the  
Ethernet Routing Switch 8300 chassis.  
See Nortel Ethernet Routing Switch 8300 Administration, NN46200-604 for  
the minimum Ethernet Routing Switch 8300 software version required to  
support the hardware.  
ATTENTION  
Nortel recommends that you install each power supply on its own dedicated  
branch circuit to ensure that a fault on another branch circuit does not cascade  
to other branch circuits.  
Prerequisites  
Verify that you have the following tools and materials:  
cable  
crimping tool for crimping the lugs onto the cable  
heat gun to shrink the tubing around the cable (optional)  
7/16-inch hex wrench  
Phillips screwdriver  
Determine the minimum number of DC power supplies to be installed.  
DC power supply installation procedures  
This task flow shows you the sequence of procedures you perform to  
install the duel input DC power supply in the Ethernet Routing Switch  
8300. To link to any tasks, go to “DC power supply installation navigation”  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
28 DC power supply installation  
DC power supply installation navigation  
Determining the minimum number of DC power supplies  
Use the following procedure to determine the minimum number of power  
supplies to install for the Ethernet Routing Switch 8300 system.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
Preparing cables for installation 29  
For more information, see Nortel Ethernet Routing Switch 8300 Installation  
— Chassis, NN46200-309.  
Procedure steps  
Step  
1
Action  
Add the total (3.3 V and 12 V) input power consumption  
(wattage) for all components (modules and fan trays or cooling  
modules).  
2
Refer to the output power rating of the power supply based on  
the input connection.  
If either the individual or the combined power requirements for  
the components exceed the power supply rating, you need to  
add at least another power supply to your configuration.  
For the 8005DI DC power supply specifications, see “Model  
8005DI DC power supply” (page 47). For the 8005DC power  
supply specifications, see “Model 8005DC power supply” (page  
3
Consider your redundant power supply needs. If one power  
supply satisfies your system power consumption needs, a  
second power supply provides redundancy. If two power  
supplies satisfy your system power consumption needs, a third  
power supply provides redundancy.  
--End--  
Preparing cables for installation  
Prepare the cables for installation of the power supply of the Ethernet  
Routing Switch 8300.  
Nortel does not supply the cables for connecting the DC power supply to  
the DC input power source. Select cables that comply with the electrical  
code of the country where you use the DC power supply.  
CAUTION  
Risk of equipment damage  
Make sure that the connection cable used with the DC power  
supply is appropriate for use with the DC power source to which  
the power supply connects. Consider gauge, flammability, and  
mechanical serviceability when you determine which cables to  
use.  
Procedure steps  
Step  
Action  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
30 DC power supply installation  
1
2
Strip 0.81 in. (2.1 cm) of insulation from the ends of the cables.  
Crimp the lugs onto the cables using a standard crimping tool.  
CAUTION  
Risk of injury by electric shock  
Failure to properly crimp the lugs onto the cables  
constitutes a safety hazard.  
3
If necessary, use a heat gun to shrink the tubing around the  
cable.  
--End--  
Job aid: Cable stripping requirements  
The illustrations in this section provide details about cable stripping  
requirements for the 8005DI DC and 8005DC power supplies.  
Removing the power filler panel  
A power filler panel maintains the proper cooling airflow in the Ethernet  
Routing Switch 8300 chassis. You must remove the power filler panel from  
the power bay when you install a power supply in a bay for the first time.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
 
Installing the DC power supply 31  
CAUTION  
To maintain proper cooling, never operate the chassis with an  
empty power supply bay. If you replace a failed power supply  
and you have no power filler panel, leave the failed power  
supply installed until a replacement power supply is available.  
Procedure steps  
Step  
1
Action  
Use a Phillips screwdriver to loosen the two captive screws that  
secure the power filler panel to the chassis until the power filler  
panel disengages.  
Pull the power filler panel from the chassis.  
2
CAUTION  
Save the power filler panel in case you need to  
operate the Ethernet Routing Switch 8300 chassis  
with a power supply removed.  
--End--  
Job aid: Power filler panel removal  
Installing the DC power supply  
Install the DC power supply to the DC input power source of the Ethernet  
Routing Switch 8300.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
32 DC power supply installation  
CAUTION  
Risk of equipment damage  
To prevent damage from electrostatic discharge, always wear  
an antistatic wrist strap connected to an ESD jack.  
DANGER  
Risk of injury by electric shock  
Before working on this equipment, be aware of proper safety  
practices and the hazards involved with electrical circuits. Use  
only power cords that have a grounding path. Ensure the switch  
is properly grounded before powering on the unit.  
Procedure steps  
Step  
1
Action  
Switch off the power supply.  
See the following figure for the exact location of the power  
switches.  
2
Remove the filler panel from the power bay if necessary.  
CAUTION  
Save the power filler panel in case you need to  
operate the Ethernet Routing Switch 8300 chassis  
with a power supply removed.  
3
4
If you are replacing a failed power supply, remove the failed DC  
power supply.  
Grasp the handle of the new power supply.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Installing the DC power supply 33  
5
6
Push the new power supply partway into the bay, leaving the  
terminal block at the side of the power supply exposed.  
Use a Phillips screwdriver to remove the screw that secures the  
plastic safety cover to the power supply and remove the cover.  
Set the cover aside; you will replace it later.  
7
8
Note the positions of the ground studs and of the positive and  
negative power inputs. See “Job aid: DC power supply input and  
Either +VDC or –VDC can be referenced to the frame ground for  
+48 VDC (nominal) or –48 VDC (nominal) applications.  
Make sure that the +DC cable is always connected to the  
positive terminal and the –DC cable is always connected to the  
negative terminal.  
DANGER  
Risk of injury by electric shock  
Before you continue with this procedure, ensure that  
the DC power source is switched off.  
9
Attach the earth ground lead to the ground stud on the power  
Use the washers in the following order:  
a flat washer  
b crimp lug  
c lock washer  
d Hex nut  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
34 DC power supply installation  
10  
Attach the positive voltage lead to the positive terminal on the  
power supply and insert a lock washer between the crimp lug  
and each hex nut.  
11  
Attach the negative voltage lead to the negative terminal on the  
power supply to insert a lock washer between the crimp lug and  
each hex nut.  
12  
13  
14  
Use a 7/16 inch hex wrench to tighten the hex nut on each  
terminal.  
Attach the earth ground cable to the system or rack ground for  
your DC input power source.  
Use a Phillips screwdriver to replace the plastic safety cover on  
the power supply.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Installing the DC power supply 35  
15  
Firmly slide the power supply all the way into the bay. See “Job  
16  
17  
Tighten the retaining screws to firmly seat the power supply.  
Attach the positive and negative terminal leads to the DC input  
power source according to the proper safety and technical  
specifications for your 48 V power distribution system.  
18  
19  
Turn the DC input power source on or reset the power source  
circuit breaker to provide power to the power supply.  
Turn the power supply switch to the on position.  
ATTENTION  
Due to the N+1 power sharing architecture, if your chassis contains  
two or three nonredundant power supplies, Nortel recommends that  
you turn on the power supplies simultaneously. If you wait longer to  
turn on the supplies, the power supplies shut off within 7 seconds. To  
correct this condition, turn off the power supplies for 2 minutes, and  
then simultaneously turn on the power supplies again.  
20  
If the LED on the power supply does not turn on, contact the  
Nortel Technical Solutions Center.  
--End--  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
36 DC power supply installation  
Job aid: Inserting the DC power supply  
Figure 1  
Inserting the DC power supply: 8306 and 8310 chassis  
Job aid: DC power supply input and ground stud location  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
Installing the DC power supply 37  
Job aid: Attaching the earth ground lead to the ground stud  
Job aid: Tightening the retaining screws on the DC power supply  
Figure 2  
Tightening the retaining screws on the DC power supply: 8306 and 8310  
chassis  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
38 DC power supply installation  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
39  
.
Translations of safety messages  
This section provides translations of the different precautionary notices  
used in this document.  
Notices  
CAUTION  
This device is a Class A product. Operation of this equipment  
in a residential area is likely to cause harmful interference, in  
which case users are required to take appropriate measures  
necessary to correct the interference at their own expense.  
CAUTION  
ATTENTION  
Le périphérique est un produit de Classe A. Le fonctionnement  
de cet équipement dans une zone résidentielle risque de causer  
des interférences nuisibles, auquel cas l’utilisateur devra y  
remédier à ses propres frais.  
CAUTION  
ACHTUNG  
Dies ist ein Gerät der Klasse A. Bei Einsatz des Geräts  
in Wohngebieten kann es Störungen des Radio- und  
Fernsehempfangs verursachen. In diesem Fall muss der  
Benutzer alle notwendigen Maßnahmen ergreifen, die  
möglicherweise nötig sind, um die Störungen auf eigene  
Rechnung zu beheben.  
CAUTION  
PRECAUCIÓN  
Este es un producto clase A. El uso de este equipo en áreas  
residenciales puede causar interferencias nocivas, en cuyo  
caso, se requerirá que los usuarios tomen cualquier medida  
necesaria para corregir la interferencia por cuenta propia.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
   
40 Translations of safety messages  
CAUTION  
CUIDADO  
Este dispositivo é um produto Classe A. Operar este  
equipamento em uma área residencial provavelmente causará  
interferência prejudicial; neste caso, espera-se que os usuários  
tomem as medidas necessárias para corrigir a interferência por  
sua própria conta.  
CAUTION  
ATTENZIONE  
Questo dispositivo è un prodotto di Classe A. Il funzionamento  
di questo apparecchio in aree residenziali potrebbe causare  
interferenze dannose, nel cui caso agli utenti verrà richiesto  
di adottare tutte le misure necessarie per porre rimedio alle  
interferenze a proprie spese.  
CAUTION  
Risk of equipment damage  
Make sure that the connection cable you use with the DC power  
supply is appropriate for use with the DC power source to which  
the power supply connects. Consider gauge, flammability, and  
mechanical serviceability when you determine which cables to  
use.  
CAUTION  
ATTENTION  
Risques d’endommagement de l’équipement  
Assurez-vous que le câble de connexion utilisé avec  
l’alimentation en courant continu est adapté à une utilisation  
avec la source d’alimentation à laquelle il est raccordé.  
Plusieurs critères tels que le calibre, l’inflammabilité et l’aptitude  
à l’usage mécanique doivent être pris en compte lorsque vous  
choisissez le câble à utiliser.  
CAUTION  
VORSICHT  
Risiko von Geräteschäden  
Vergewissern Sie sich, dass für den Anschluss des  
Gleichstrom-Netzteils an die Gleichstromquelle ein für diese  
Quelle geeignetes Verbindungskabel verwendet wird. Bei der  
Auswahl der Kabel sind Dicke, Brennbarkeit und mechanische  
Tauglichkeit der Kabel zu beachten.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Notices 41  
CAUTION  
PRECAUCIÓN  
Riesgo de daños en los equipos  
Controle que el cable de conexión que utilice con la fuente de  
alimentación de CC sea el adecuado. Para determinar qué  
cables debe utilizar, evalúe el calibre, la inflamabilidad y la  
funcionalidad mecánica.  
CAUTION  
CUIDADO  
Risco de danos ao equipamento  
Verifique se o cabo de conexão a ser usado com a fonte  
de alimentação DC é adequado para ser usado na fonte de  
alimentação DC na qual a fonte de alimentação está conectada.  
Considere a medida, a flamabilidade e a resistência mecânica  
ao determinar quais cabos podem ser usados.  
CAUTION  
ATTENZIONE  
Rischio di danno all’apparecchio  
Assicurarsi che il cavo di connessione utilizzato con  
l’alimentatore c.c. sia appropriato all’utilizzo con la sorgente  
di alimentazione c.c. al quale l’alimentatore è collegato.  
Nella scelta dei cavi da utilizzare, considerarne lo spessore,  
l’infiammabilità e lo stato di efficienza meccanica.  
CAUTION  
Risk of equipment damage  
To prevent damage from electrostatic discharge, always wear  
an antistatic wrist strap connected to an ESD jack.  
CAUTION  
ATTENTION  
Risque d’endommagement de l’équipement  
Pour prévenir tout dommage dû à une décharge électrostatique,  
vous devez toujours porter un un bracelet antistatique connecté  
à une prise ESD.  
CAUTION  
ACHTUNG  
Risiko eines Geräteschadens Um Schäden  
durch elektrostatische Entladung zu verhindern, tragen Sie bei  
der Instandhaltung dieses Produkts immer ein antistatisches  
Band am Handgelenk, welches mit einer ESD-Buchse  
verbunden ist.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
42 Translations of safety messages  
CAUTION  
PRECAUCIÓN  
Riesgo de daño del equipo  
Para prevenir el daño producido por una descarga  
electrostática, use siempre una pulsera antiestática conectada a  
un enchufe ESD.  
CAUTION  
CUIDADO  
Risco de danos ao equipamento  
Para evitar danos com descarga eletrostática, sempre use uma  
pulseira antiestática que esteja conectada a uma tomada ESD.  
CAUTION  
ATTENZIONE  
Rischio di danni all’apparecchiatura  
Per evitare danni derivanti da scariche elettrostatiche, indossare  
sempre un polsino antistatico collegato a una presa ESD.  
DANGER  
Risk of injury by electric shock  
Failure to properly crimp the lugs onto the cables constitutes a  
safety hazard.  
DANGER  
Risques de blessure par choc électrique  
Pour votre sécurité, vérifiez que les cosses sont correctement  
serties sur les câbles.  
DANGER  
Pour votre sécurité, vérifiez que les cosses sont  
correctement serties sur les câbles.  
Verletzungsrisiko durch Stromschlag  
Es besteht ein Sicherheitsrisiko, wenn die Anschlussstücke nicht  
ordnungsgemäß auf die Kabel geklemmt werden.  
DANGER  
PELIGRO  
Riesgo de lesiones por choques eléctricos  
Para evitar riesgos, pliegue correctamente hacia adentro los  
terminales de los cables.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Notices 43  
DANGER  
PERIGO  
Risco de ferimento por choque elétrico  
Enrolar os suportes aos cabos de maneira incorreta implica em  
um risco de segurança.  
DANGER  
PERICOLO  
Rischio di lesioni per shock elettrico  
Il piegamento non corretto delle linguette nei cavi costituisce un  
rischio per la sicurezza.  
CAUTION  
To maintain proper cooling, never operate the Ethernet Routing  
Switch 8300 with an empty power supply bay. If you are  
replacing a failed power supply and you do not have a power  
filler panel, leave the failed power supply installed until a  
replacement power supply is available.  
CAUTION  
ATTENTION  
Pour garantir une ventilation adaptée, n’utilisez jamais le  
Ethernet Routing Switch 8300 lorsque la baie d’alimentation est  
vide. Ne retirez pas une alimentation, même défectueuse, si  
vous ne disposez pas d’un panneau de remplissage à installer  
à sa place.  
CAUTION  
ACHTUNG  
Zur Gewährleistung einer ordnungsgemäßen Kühlung nehmen  
Sie Ethernet Routing Switch 8300 niemals in Betrieb, wenn  
ein Netzteilschacht unbesetzt ist. Wenn Sie ein defektes  
Netzteil ersetzen, ohne eine Aussparungsabdeckung zur Hand  
zu haben, lassen Sie das defekte Netzteil installiert, bis ein  
Ersatz-Netzteil verfügbar ist.  
CAUTION  
PRECAUCIÓN  
Para mantener una refrigeración adecuada, no opere Ethernet  
Routing Switch 8300 con el compartimiento de la fuente de  
alimentación vacío. Si necesita reemplazar una fuente de  
alimentación defectuosa y no cuenta con un panel de relleno de  
energía, no la extraiga hasta tanto consiga el repuesto.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
44 Translations of safety messages  
CAUTION  
CUIDADO  
Para manter o resfriamento adequado, nunca opere o  
Ethernet Routing Switch 8300 com um compartimento de  
fonte de alimentação vazio. Se você estiver substituindo uma  
fonte de alimentação com defeito e não tiver um painel de  
preenchimento de energia, deixe fonte com defeito instalada até  
que a fonte de substituição esteja disponível.  
CAUTION  
ATTENZIONE  
Per mantenere un raffreddamento appropriato, non utilizzare  
mai il Ethernet Routing Switch 8300 con il vano di alimentazione  
vuoto. Se si sostituisce un alimentatore guasto e non si dispone  
di un pannello di riempimento, lasciare installato l’alimentatore  
guasto finché non sarà disponibile un alimentatore per la  
sostituzione.  
CAUTION  
Save the power filler in case you need to operate the Ethernet  
Routing Switch 8300 with a power supply removed.  
CAUTION  
ATTENTION  
Conservez le panneau de remplissage. Il vous sera utile si vous  
devez utiliser le Ethernet Routing Switch 8300 sans source  
d’alimentation.  
CAUTION  
ACHTUNG  
Bewahren Sie die Aussparungsabdeckung für den Fall auf, dass  
Sie Ethernet Routing Switch 8300 verwenden müssen, wenn  
ein Netzteil entfernt ist.  
CAUTION  
PRECAUCIÓN  
Conserve el panel de relleno de energía para utilizarlo en caso  
de ser necesario operar Ethernet Routing Switch 8300 sin una  
fuente de alimentación.  
CAUTION  
CUIDADO  
Guarde o painel de preenchimento de energia caso seja  
preciso operar o Ethernet Routing Switch 8300 sem a fonte de  
alimentação.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Notices 45  
CAUTION  
ATTENZIONE  
Conservare il pannello di riempimento dell’alimentatore nel caso  
in cui sia necessario utilizzare il Ethernet Routing Switch 8300  
con l’alimentatore rimosso.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
46 Translations of safety messages  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
47  
.
Appendix  
Technical specifications  
This appendix lists the electrical specifications for the 8005DI DC power  
supplies.  
Technical specifications navigation  
Model 8005DI DC power supply  
This section provides power ratings for the 8005DI DC input power supply  
and output power supply.  
DC input power specifications  
The following table describes the technical specifications for DC input  
power for Model 8005DI DC power supply.  
Table 4  
DC input power specifications for Model 8005DI DC power supply  
Parameter  
Specifications  
40 VDC/75 VDC  
48.75/32.5 A  
1.95 kVA  
Input voltage  
Input current  
Input VA  
Input power consumption  
Heat dissipation (thermal/output)  
1950 W  
1666 Btu/hr  
DC output power specifications  
The following table describes the technical specifications for DC input  
power for Model 8005DI DC power supply.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
         
48 Technical specifications  
Table 5  
DC output power specifications for Model 8005DI DC power supply  
Parameter  
Specifications  
1462 W continuous, 1660 W  
peak with forced air cooling  
Output power (maximum)  
Modules  
3.3 V @ 150 A  
12 V @ 72 A  
Fans  
12 VDC @ 7.5 A/ 24 A peak  
108 803 hr  
(Bellcore TR–332 standard)  
MTBF  
Model 8005DC power supply  
This section provides power ratings for the 8005DC input power supply  
and output power supply.  
DC input power specifications  
The following table describes the technical specifications for DC input  
power for Model 8005DC power supply.  
Table 6  
DC input power specifications for Model 8005DC power supply  
Parameter  
Specifications  
– 48 VDC/ – 60 VDC  
42/34 A  
Input voltage  
Input current  
Input VA  
1.95 kVA  
Input power consumption  
Heat dissipation (thermal/output)  
1950 W  
1666 Btu/hr  
DC output power specifications  
The following table describes the technical specifications for DC input  
power for Model 8005DC power supply.  
Table 7  
DC output power specifications for Model 8005DC power supply  
Parameter  
Specifications  
Output power (maximum)  
Modules  
1462 W (1372 W + 90 W fans)  
3.3 V @ 150 A  
12 V @ 72 A  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
     
Model 8005DC power supply 49  
Table 7  
DC output power specifications for Model 8005DC power supply (cont’d.)  
Parameter  
Fans  
Specifications  
12 VDC @ 7.5 A/ 24 A peak  
MTBF  
108 803 hr  
(Bellcore TR–332 standard)  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
50 Technical specifications  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
NN46200-310 01.01 Standard  
9 June 2008  
Copyright © 2008 Nortel Networks  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.
Download from Www.Somanuals.com. All Manuals Search And Download.  
Nortel Ethernet Routing Switch 8300  
Installation — DC Power Supply  
Copyright © 2008 Nortel Networks  
All Rights Reserved.  
Printed in Canada and the United States of America  
Release: 4.1  
Publication: NN46200-310  
Document status: Standard  
Document revision: 01.01  
Document release date: 9 June 2008  
To provide feedback or to report a problem in this document, go to www.nortel.com/documentfeedback.  
LEGAL NOTICE  
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing  
NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS  
OR IMPLIED. The information and/or products described in this document are subject to change without notice.  
Nortel, the Nortel logo, and the Globemark are trademarks of Nortel Networks.  
All other trademarks are the property of their respective owners.  
ATTENTION  
For information about the regulatory and safety precautions, read "Regulatory messages and safety  
precautions" in this guide.  
For information about the software license, read "Software license" in this guide.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Cooktop 09 733 840 User Manual
Miller Electric Welder RHC 3 User Manual
Napa Essentials Battery Charger 85 303 User Manual
NETGEAR Switch FS728TP User Manual
Nikon Camera Flash DMF880 User Manual
Niles Audio Stereo Amplifier SI 2100 User Manual
Nilfisk ALTO Vacuum Cleaner Sweeper PS 27 User Manual
Outback Power Systems Battery Charger OBX IC2024S 120 60 User Manual
Outlaw Audio Speaker ECS 10 User Manual
Panasonic Cordless Drill EY6535 U1 User Manual