Nokia Cell Phone 21XX User Manual

Nokia  
NetMonitor  
Manual  
Version 0.95  
11.11.2002  
Document keeper  
Base document  
PDF + Enhancements to base document  
Graphics  
: nobbi  
: nobbi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Menu Modes  
There are three Menu Display modes:  
-
-
-
the execute mode  
the data display mode  
the help mode  
Different modes are marked in this manual as follows:  
**************  
++++++++++++++  
##############  
*
*
+
+
#
#
#
#
#
#
#
#
* Execute *  
+Data display+  
Help  
Mode  
*
*
Mode  
*
*
+
+
Mode  
+
+
**************  
++++++++++++++  
##############  
The execute mode is entered from the menu by selecting a menu directly with his number. If the test  
index entered pertains to a test that resets a timer (test 80) for example, then the timer is reset as soon  
as the OK button has been pressed in the menu, and the data display mode takes over. In other words,  
the execute mode is of the one-shot type. To run another test in the execute mode, the Field Test  
Display menu must be reactivated.  
So, be very careful when jumping to a netmonitor page directly from the menu selection. You may  
activate the execute mode incidentally, causing your phone to behave not as expected.  
The data display mode is active by default when the Netmonitor is active. During data display mode, the  
field test data is visible on the main display.  
During help mode, one screen of instructions is shown for each test to make it easier to identify the test  
in question. A long press of the asterisk (*) is used to toggle between these two modes.  
The arrow keys (^,v) offer an easy way to switch to another test without using the menu. However,  
nothing will be executed or set on although such tests would be passed. This is to prevent the user from  
accidentally clearing any valuable data. The help mode is also a non-execute mode. Display numbers  
have been selected in such way that no 5-terminated test number is an execute display.  
Reserving SIM phonebook locations  
When using a phone with enabled field test displays, it is highly recommended to put some default data  
into the SIM phonebook locations that are used by some field test displays. Especially Test 17 (BTS  
TEST) may give some confusing results if SIM phonebook location 33 is not correctly configured.  
Additionally, this prevents accidental storing of phone numbers and names into such locations.  
Displays 52 and 53 may also write some data to the SIM phonebook locations 35 and 36.  
Location  
31  
32  
33  
34,35,36  
Default  
65535  
65535  
0
Data Used by Display #  
71  
72  
17 (BTS TEST)  
52, 53  
34,35,36  
Reserving SIM SCM locations is not necessary if the user is sure that he will never select these displays  
using menu shortcut (which executes the display in question).  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Table of contents  
Basics: Channel numbers in GSM  
GSM uses channel numbers between 0 and 1023. These frequency channels are allocated  
by the different types of GSM as follows:  
Type:  
Subtype: Channels:  
GSM400  
GSM450  
GSM480  
GSM750  
GSM850  
PGSM  
259 .. 293  
306 .. 340  
438 .. 511  
128 .. 251  
1 .. 124  
GSM700  
GSM850  
GSM900  
EGSM  
0 .. 124  
975 .. 1023  
0 .. 124  
GSM-R  
955 .. 1023  
512 .. 885  
512 .. 810  
GSM1800  
GSM1900  
GSM1800  
GSM1900  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Display 1 – Serving cell info  
++++++++++++++  
+abbb ccc ddd+  
+ e ff g mmmm+  
##############  
#CH RxL TxPwr#  
#TS TA RQ RLT#  
+ nnn  
+
ppp+  
+
# C1  
#
C2 #  
#
oooo  
CHT  
++++++++++++++  
##############  
a
bbb  
H, if carrier numbers are scrolled when hopping is on. Otherwise ' '.  
When mobile is on a TCH :  
DCH carrier number in decimal.  
When mobile is NOT on a TCH :  
CH means carrier number in decimal.  
If hopping is on, used channels are scrolled when display is updated.  
rx level in dBm, minus sign is not shown if <=-100  
tx power level. If transmitter is on, symbol * is shown in front of the  
power level value.  
ccc  
ddd  
e
ff  
g
Time Slot, range is 0 - 7  
Timing advance, range is 0 – 63  
RX quality (sub), range is 0 - 7  
mmmm  
Radio Link Timeout value. If value is negative, 0 is shown.  
Maximum value is 64. When mobile is NOT on TCH then xx is shown.  
value of the path loss criterium (C1). Range is -99 - 999.  
type of current channel (TCH := Traffic Channel):  
THR0 : TCH HalfRate (HR) subchannel 0  
nnn  
oooo  
THR1 : TCH HR subchannel 1  
TFR : TCH FullRate (FR)  
TEFR : TCH EnhancedFullRate  
F144 : TCH FR data channel, speed 14.4 kbps  
F96 : TCH FR data channel, speed 9.6 kbps  
F72 : TCH FR data channel, speed 7.2 kbps  
F48 : TCH FR data channel, speed 4.8 kbps  
F24 : TCH FR data channel, speed 2.4 kbps  
H480 : TCH HR data channel, speed 4.8 kbps, subch 0  
H481 : TCH HR data channel, speed 4.8 kbps, subch 1  
H240 : TCH HR data channel, speed 2.4 kbps, subch 0  
H241 : TCH HR data channel, speed 2.4 kbps, subch 1  
FA : TCH FR signalling only (FACCH) channel  
FAH0 : TCH HR signalling only (FACCH) channel, subch 0  
FAH1 : TCH HR signalling only (FACCH) channel, subch 1  
SDCC : SDCCH  
AGCH : Access Grant CHannel  
CCCH : one of the Common Control CHannels  
CBCH : CCCH and cell broadcast receiving on  
BCCH : Broadcast Control CHannel  
SEAR : SEARCHing for available networks  
NSPS : MS is in ’No Service, Power Save’ state  
ppp  
value of the cell reselection criterium (C2).  
Range is -99 to 999. If phone is phase 1 then C1 value is shown.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Display 2 – More info about serving cell  
++++++++++++++  
+ aa b c Bdd +  
##############  
#PM RAR Ro BC#  
#RelR QLF #  
+ ee f  
+
+ ggg hh iii +  
+ H=j mm nn +  
++++++++++++++  
#CRO TO PenT #  
#H MAIO HSN #  
##############  
aa  
paging mode  
NO : normal paging  
EX : extended paging  
RO : paging reorganization  
SB : same as before  
b
maximum number of Random Access retransmission  
roaming indicator, values are 'R' or ' '.  
Letter B and BSIC value, range is 0 - 63.  
RX quality (full), range is 0 - 7  
Cell reselection offset, range 0 - 126 dB.  
[0 .. 63] * 2 dB. 'xxx' in dedicated mode.  
Temporary offset, range 0 - 60 dB.  
[0 .. 7] * 10 dB. 70 dB means infinite time.  
'xx' in dedicated mode.  
c
Bdd  
ee  
f
ggg  
hh  
iii  
j
Penalty time, range 0 - 620 s.  
[0 .. 31] * 20 s. 'xxx' in dedicated mode.  
Hopping channel  
0 Single RF channel  
1 RF hopping channel  
mm  
nn  
mobile allocation index offset, MAIO  
Range: 00 to 63 / xx when H=0  
hopping sequence number, HSN  
Range: 00 to 63 / xx when H=0  
Display 3 – Serving cell, 1st and 2nd neighbour  
++++++++++++++  
+aaabbbcccddd+  
+aaabbbcccddd+  
+aaabbbcccddd+  
##############  
#SCH C1 rx C2#  
#1CH C1 rx C2#  
#2CH C1 rx C2#  
+
ef gh +  
#
1N 2N #  
++++++++++++++  
##############  
1. row: serving cell information  
2. row: 1. neighbour information  
3. row: 2. neighbour information  
4. row, ef: 1. neighbour information  
4. row, gh: 2. neighbour information  
aaa  
bbb  
carrier number in decimal, EGSM channels are displayed as Eaa  
idle mode : C1 value, range is -99 - 999  
ded. Mode : 'B' and BSIC value  
RX level in dBm, minus sign is not shown if <=-100  
C2 value, range is -99 - 999  
ccc  
ddd  
e,g  
f,h  
F : cell is in a forbidden location area  
B : cell is barred  
N : cell is normal priority  
L : cell is low priority  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 4 & 5 – 3rd to 8th neighbour cell  
++++++++++++++  
+aaabbbcccddd+  
+aaabbbcccddd+  
+aaabbbcccddd+  
+ ef gh ij +  
++++++++++++++  
##############  
#3CH C1 rx C2#  
#4CH C1 rx C2#  
#5CH C1 rx C2#  
# 3N 4N 5N #  
##############  
1. row: 3./6. neighbour information  
2. row: 4./7. neighbour information  
3. row: 5./8. neighbour information  
4. row, ef: 3./6. neighbour information  
4. row, gh: 4./7. neighbour information  
4. row, ij: 5./8. neighbour information  
aaa  
bbb  
carrier number in decimal, EGSM channels are displayed as Eaa  
idle mode : C1 value, range is -99 - 999  
ded. Mode : 'B' and BSIC value  
rx level in dBm, minus sign is not shown if <=-100  
C2 value, range is -99 - 999  
ccc  
ddd  
e,g,i  
f,h,j  
F : cell is in a forbidden location area  
B : cell is barred  
N : cell is normal priority  
L : cell is low priority  
Display 6 – Network selection display  
++++++++++++++  
+aaabb aaabb+  
+aaabb aaabb+  
+aaabb aaabb+  
+aaabb aaabb+  
++++++++++++++  
##############  
#LReg 1_For#  
#1_Pre 2_For#  
#2_Pre 3_For#  
#3_Pre 4_For#  
##############  
This display shows the last registered networks country code (MCC) and  
network code (MNC) as well as the codes for four forbidden networks  
and the first 3 preferred networks.  
If a three-digit MNC is used (GSM1900), display looks different:  
++++++++++++++  
+aaabbbaaabbb+  
+aaabbbaaabbb+  
+aaabbbaaabbb+  
+aaabbbaaabbb+  
++++++++++++++  
1. row: last registered network - 1st forbidden network  
2. row: 1st preferred network - 2nd forbidden network  
3. row: 2nd preferred network - 3rd forbidden network  
4. row: 3rd preferred network - 4th forbidden network  
aaa  
bbb  
country code coded in BCD  
network code coded in BCD, third digit can be 'F'  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 7 – System information bits for serving cell  
++++++++++++++  
+E A H C I BR+  
+a b c d e fg+  
+ECSC 2Ter MB+  
##############  
#Serving Cell#  
#System Info #  
#Bits  
#
#
#
+ h  
i j+  
++++++++++++++  
##############  
a
b
c
d
e
f
g
1 is shown if emergency calls are supported  
1 is shown if attach-detach-procedure is allowed  
1 is shown if half rate channels are supported  
1 is shown if C2 values are broadcasted  
1 is shown if system information 7 and 8 are broadcasted  
1 is shown if cell broadcast is supported  
1 is shown if re-establishment is supported  
The following items are used only in dualband phones:  
h
i
j
In idle mode 1 is shown if Early Classmark (ECSC) sending is supported.  
In dedicated mode (conversation) X is shown.  
In idle mode 1 is shown if 2Ter messages are supported.  
In dedicated mode (conversation) X is shown.  
MultiBand reporting decimal value (0,1,2,3) is shown if supported.  
This is shown both in idle and dedicated mode.  
The following is picked from Phase2+ ETSI ETS 300578 (TS GSM 05.08), Section 8.4.3  
"Additional cell reporting requirements for multi band MS".  
For a multi band MS the number of cells, for each frequency band supported, which  
shall be included in the measurement report is indicated by the parameter,  
MULTIBAND_REPORTING. The meaning of different values of the parameter is specified as  
follows:  
Value  
Meaning  
00 (0)  
Normal reporting of the six strongest cells, with known and allowed NCC part  
of BSIC, irrespective of the band used.  
01 (1)  
The MS shall report the strongest cell, with known and allowed NCC part of  
BSIC, in each of the frequency bands in the BA list, excluding the frequency  
band of the serving cell. The remaining positions in the measurement report  
shall be used for reporting of cells in the band of the serving cell. If  
there are still remaining positions, these shall be used to report the next  
strongest identified cells in the other bands irrespective of the band used.  
10 (2)  
The MS shall report the two strongest cells, with known and allowed NCC part  
of BSIC, in each of the frequency bands in the BA list, excluding the  
frequency band of the serving cell. The remaining positions in the  
measurement report shall be used for reporting of cells in the band of the  
serving cell. If there are still remaining positions, these shall be used to  
report the next strongest identified cells in the other bands irrespective  
of the band used.  
11 (3)  
The MS shall report the three strongest cells, with known and allowed NCC  
part of BSIC, in each of the frequency bands in the BA list, excluding the  
frequency band of the serving cell. The remaining positions in the  
measurement report shall be used for reporting of cells in the band of the  
serving cell. If there are still remaining positions, these shall be used to  
report the next strongest identified cells in the other bands irrespective  
of the band used.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 10 – Paging Repetition Period, TMSI, Location Update Timer, AFC and AGC  
++++++++++++++  
+TMSIaaaaaaaa+  
+T321:bbb/ccc+  
+PRP:d ee ff+  
+ ggggg hhh +  
++++++++++++++  
##############  
#TMSI(hex) #  
#T3212ctr/tim#  
#PaRP DSF AGC#  
# AFC Ch #  
##############  
aaaaaaaa  
bbb  
last assigned TMSI value in hex format  
Current value of T3212 counter (range is 000 - 'ccc'), where 1 means 6 min  
time. So, if this value is 2 less than 'ccc' then next periodic location  
updating will be made within 2 * 6 min = 12 minutes.  
ccc  
Timeout value of T3212 counter (range is 000 - 240, where 1 means 6 min  
time between location updates and 240 means 240 * 6 min = 24 h between  
location updates. 000 means that a periodic location update will not  
occur) This value is received from the network.  
Value of paging repetition period (range is 2 – 9, which means paging will  
be in every Xth multiframe. When paging is in every second multiframe,  
mobile takes more current than if it were in every 9th multiframe)  
Downlink signalling failure value. If value is negative, 0 is shown.  
Maximum value is 45. When mobile is on TCH then xx is shown.  
Gain value on TCH/SDCCH, range is 0 - 93  
d
ee  
ff  
ggggg  
hhh  
VCTCXO AFC DAC control, range is -1024 - 1023  
Serving cell channel number  
Display 11 – Network parameters  
++++++++++++++  
+CC:aaa NCbbb+  
+ LAC:ccccc +  
+ CH : dddd +  
+ CID:eeeee +  
++++++++++++++  
##############  
# MCC MNC #  
#LocAreaCode #  
#ServChannel #  
# CellId #  
##############  
aaa  
bbb  
MCC value in decimal (MCC=Mobile Country Code)  
MNC value in decimal (MNC=Mobile Network Code)  
Three digits are shown only in GSM1900.  
Two digits are shown in GSM900 and GSM1800.  
LAC value in decimal (in older SW-versions this value is in hexadecimal)  
Serving cell channel number  
Cell Identifier in decimal (in older SW-versions this value is in  
hexadecimal)  
ccccc  
dddd  
eeeee  
Display 12 – Ciphering, hopping, DTX Status and IMSI  
++++++++++++++  
+CIPHER :aaa +  
+HOPPING:bbb +  
##############  
#CipherValue #  
#HoppingValue#  
+DTX  
:ccc +  
#DTXValue  
#
+IMSI :ddd +  
++++++++++++++  
#IMSIAttach #  
##############  
aaa  
bbb  
ccc  
ddd  
ciphering value, OFF/A51/A52  
hopping value, ON/OFF  
DTX value ON/OFF  
IMSI attach  
ON : IMSI attach on  
OFF : IMSI attach off  
These values are updated only on when the phone is active on a TCH.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Display 13 – Uplink DTX switching display  
**************  
*aaaaaaaaaa *  
*DTX(DEF):bbb*  
*DTX(BS) :ccc*  
##############  
#DTXMode  
#DefaulDTXSta#  
#DTXValFromBS#  
#
*
*
#
#
**************  
##############  
With this display it is possible to see whether the MS uses DTX or not.  
This display must be activated from MENU to change DTX state. When MENU is not active  
and the user is scrolling field test displays with NEXT and PREVIOUS, the DTX state  
will not be changed.  
aaaaaaaaaa status of switched mode.  
DTX:ON  
: MS uses DTX  
DTX:OFF : MS does not use DTX  
DTX:DEF : MS use default state of DTX  
NOTALLOWED: BS does not allow MS to decide if it uses  
DTX or not.  
bbb  
ccc  
default state of DTX in MS. The value is either ON or OFF  
is DTX value from BS  
MAY : BS allows MS to decide if it uses uplink DTX or not  
USE : BS controls MS to use DTX (on uplink)  
NOT : BS controls MS not to use DTX (on uplink)  
Display 14 – Toggle Screening Indicator  
**************  
* SCREENING *  
* INDICATOR *  
##############  
#Use menu to #  
# change  
#
*
*
IS XX * XX : 00 or 01  
*
# Screening #  
# indicator #  
##############  
**************  
When selected, changes the value of the Screening Indicator from 0 to 1 and vice  
versa.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 17 – Switch 'BTS Test' Status  
**************  
**************  
##############  
#Use menu to #  
#toggle BTS #  
#test ON/OFF #  
*
*
*
*
* BTS TEST *  
* BTS TEST *  
*
*
ON  
*
*
*
*
OFF  
*
*
#
#
**************  
**************  
##############  
This display is used to toggle the BTS_TEST flag in EEPROM. If BTS_TEST is set then  
each time the mobile sends a search list it uses only the carrier number stored on  
SIM phonebook location 33. Also the neighbour information from system information  
messages is ignored. If the BTS_TEST flag is not set, then the value of SIM phonebook  
location 33 is ignored and the mobile behaves normally (i.e. does neighbour  
measurements according to GSM specifications).  
To activate BTS TEST perform the following steps:  
- Save desired channel number in SIM phonebook location 33  
- Select display 17 in execute mode  
- Switch power off and on OR force a cell reselection  
If activation succeeded, you will read "BTS TEST ON" in display 17. The 6210 will  
show "BTS TEST REQUESTED" instead.  
To deactivate BTS tests either select display 17 in execute mode or save a number in  
SIM phonebook location 33 which does NOT represent a valid carrier number, then  
switch power off and on OR force a cell reselection  
CAUTION! The display does not show the value of the BTS_TEST flag in EEPROM. Although  
the value is set, BTS_TEST can show to be off. If there is no legal carrier number in  
SIM phonebook location 33 (GSM900: 1-124, GSM1800: 512-885, EGSM: 0, 975-1023) the  
display shows that BTS_TEST is off. Also if the mobile was already registered to some  
carrier before switching BTS_TEST status, the display can show a different value from  
the one in EEPROM.  
Display 18 – Lights status control  
Forces keyboard and display lights on/off while displaying any netmonitor screen. The  
light will not remain on after leaving netmonitor  
**************  
**************  
##############  
#Use menu to #  
*
*
*
*
* LIGHTS *  
* LIGHTS *  
# toggle  
# lights  
# ON/OFF  
#
#
#
*
*
ON  
*
*
*
*
OFF  
*
*
**************  
**************  
##############  
Display 19 – Toggle Cell Barred Status  
************** ************** ************** ##############  
* * * * * #Use menu to #  
* CELL BARR * * CELL BARR * * CELL BARR * #toggle cell #  
*
* ACCEPTED * * REVERSE  
* *  
* * DISCARD  
* *  
* #barr status #  
* #DIS/ACC/REV #  
*
************** ************** ************** ##############  
This test is meant to be used when some cells are tested before taking them into  
commercial use. By setting the CELL_BARRED to on in the base station normal GSM  
phones will not try to camp on these barred cells.  
By selecting CELL BARR REVERSE, the MS will only use the cells which have CELL_BARRED  
set.  
By selecting CELL BARR DISCARD, the MS will use all cells, irrespective wether  
CELL_BARRED is set or not.  
NOTE: If a cell has been selected before barring state in phone is changed the  
selected cell will remain the current cell. After the next cell reselection the cell  
barring state is working as expected.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 20 – Charging state  
**************  
* aaa bbbbb *  
* Tccc dddd *  
* Ceee Wfff *  
* gggg hhhh *  
**************  
##############  
#BatVol ChMod#  
#Btemp ChTime#  
#ChrgVol Pwm #  
# Btyp BFDC #  
##############  
aaa  
Battery voltage in decimal, range is 0.00 - 9.99 V, decimal point is not  
shown; e.g. 7.19 V is shown as 719 on the display  
bbbbb Charging mode 5 digit symbol:  
xxxxx : Charger not connected or charging disabled.  
BatCk : Battery testing is going.  
BSIFa : Charging off because of battery BSI measurement failed.  
CelBr : Charging off because one or more cells broken inside  
battery.  
ChaCk : EM is checking charger.  
Charg : Charging.  
ColdC : Cold charging.  
ColdM : Battery cold and maintenance going.  
CurFa : Charging off because charger current measurement failed.  
DisCh : Battery discharging going.  
F_Che : Fast charging checks.  
Faile : Failure.  
FastC : Fast charging going.  
FullM : Battery full and maintenance going.  
HotM : Battery hot and maintenance going.  
I_Che : Init checks.  
InitC : EM charging is being initialized.  
L_Che : Li charging checks.  
LiAFu : PWM level is below the battery full limit.  
LiDCH : Li-ion DCH charging.  
LiFul : PWM has been below the battey full limit for a certain time  
that is specified for full battery.  
LiHot : Li-ion hot charging.  
LithC : Charging of Lithium-ion battery.  
LiTxO : TX on and Li charging going.  
LNFTx : TX on, Li charging going and battery is not full anymore.  
M_Che : Maintenace charging checks.  
MaBFD : Maintenace BFD charging.  
Maint : Maintenance charging.  
TmpFa : Charging off because of battery NTC measurement failed.  
TxNoF : TX on, Ni charging going and battery is not full anymore.  
TxOnC : TX on and Ni charging going.  
VolFa : Charging off because charger voltage measurement failed.  
ccc  
ddd  
Battery temperature in centigrade, from -30 to +90.  
Charging time. Format is HMM. Timer is automatically reset and started when  
charger is connected and stopped when battery is full or charger is  
disconnected.  
eee  
fff  
Charger voltage in decimal, range is 0.0 - 18.7 V, decimal point is not shown.  
Charge control output, decimal, range is 000 - 255.  
gggg  
hhhh  
Lithium battery type (BSI value multiplied by 4), or NiMH battery size.  
Battery full delay counter. When battery is getting full and charging current  
is less than predefined limit, this timer will be started. If timer reaches 0,  
charging will be stopped.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Display 21 – Constant voltage charging display  
**************  
* aaaa bbbb *  
* cccc dddd *  
* eeee ffff *  
##############  
#MTDif MPDif #  
#BupV BDownV#  
#AverV SumMF #  
*
*
#
#
**************  
##############  
aaaa  
bbbb  
Difference between measured voltage and goal voltage, decimal point is not  
shown.  
Difference between measured voltage and result of previous measurement  
(basically same as using change of error), decimal point is not shown.  
Battery up voltage (highest measured voltage), maximum ripple voltage.  
Battery down voltage (lowest measured voltage), minimum ripple voltage.  
Average measured voltage.  
Sum of membership function sets beliefs, range 0.00-9.99, decimal point is  
not shown; e.g. 1.53 is shown as 153. If sum of 1.00 is reached then battery  
full indication is shown.  
ccc  
ddd  
eee  
fff  
Display 22 – Battery full detection  
**************  
* Eaaa Cbbb *  
* Dccc Rddd *  
* Ieee Afff *  
* Tggg hhhh *  
**************  
##############  
#DeriC ChAm #  
# VDif VDrop #  
# VDTi AvDif #  
# Temp Volt #  
##############  
Letters E, C, D, R, I, A, T and V are displayed if values are shorter than 4 digits.  
Eaaa  
Cbbb  
Dccc  
Rddd  
Ieee  
Afff  
Tggg  
Vhhh  
DerivCount membership function set, range 0.00-1.00, decimal point is not  
shown; e.g. 0.23 is shown as 023.  
ChargeAmount membership function set, range 0.00-1.00, decimal point is not  
shown; e.g. 0.23 is shown as 023.  
VolDiffToMax membership function set, range 0.00-1.00, decimal point is not  
shown; e.g. 0.23 is shown as 023.  
VolDropCnt membership function set, range 0.00-1.00, decimal point is not  
shown; e.g. 0.23 is shown as 023.  
VolDiffTime membership function set, range 0.00-1.00, decimal point is not  
shown; e.g. 0.23 is shown as 023.  
AverDiff membership function set, range 0.00-1.00, decimal point is not  
shown; e.g. 0.23 is shown as 023.  
Temperature membership function set, range 0.00-1.00, decimal point is not  
shown; e.g. 0.23 is shown as 023.  
Voltage membership function set, range 0.00-1.00, decimal point is not  
shown; e.g. 0.23 is shown as 023.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 23 – Battery and phone state monitor  
**************  
* aaaa bbbb *  
* cccc dddd *  
*eee fff gggg*  
*hhh iiiijjjj*  
**************  
##############  
#TxOn TxOff#  
#ChCur Stdby#  
#Age CAP Curr#  
#Tmp CmAhTarg#  
##############  
aaaa  
bbbb  
TXon voltage (expected voltage with transmitter switched on), decimal point  
not shown (a.aaa mV)  
TXoff voltage (expected voltage with transmitter switched off), decimal  
point not shown (b.bbb mV)  
cccc  
dddd  
charging current, decimal point not shown (c.ccc mA)  
predicted standby level (expected voltage in standby mode), decimal point  
not shown (d.ddd mV)  
estimated age for Li-ion battery (0:new to 100:old). NiMH always shows 33  
battery's percentage level (0,25,50,100)  
eee  
fff  
gggg  
hhh  
iiii  
jjjj  
current consumption indicated by PSM (0.1 mA)  
battery's temperature (C) (Only for Li battery)  
charged capacity (mAh) into battery  
tells what is the next capacity target (mAh) to reach for next battery bar  
level to be displayed  
Display 24 – BSI values  
**************  
* aaaa bbbb *  
##############  
#V_inst V_avg#  
#BSI value #  
#Elapsed time#  
#RST_m RST_h#  
##############  
*
*
cccc *  
dddd *  
* eeee ffff *  
**************  
aaaa  
bbbb  
cccc  
dddd  
eeee  
ffff  
BSI (Battery Size Indicator) value  
minutes elapsed since charger was disconnected or phone was switched on  
Display 30 – Audio API register display  
**************  
* aaaa bbbb *  
* cccc dddd *  
* eeee ffff *  
* gggg hhhh *  
**************  
##############  
#A1Cnf A2Cnf#  
# ST AU3 #  
#1Tone 2Tone#  
# Conf HFVol#  
##############  
aaaa  
bbbb  
cccc  
dddd  
eeee  
ffff  
gggg  
hhhh  
API_AUD1_CTRL  
API_AUD2_CTRL  
API_SIDETONE  
API_AU3  
API_1_TONE (first frequency of DTMF generator)  
API_2_TONE (first frequency of DTMF generator)  
API_CONFIG  
API_HF_VOL (Volume setting for Audio output)  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 34 – FBUS display  
**************  
##############  
#CM LD LM NM #  
#PEC FEC OEC #  
#ACC RXS TXS #  
*aabbccdd  
*
*eeefff - ggg*  
*hhh iii jjj *  
*k--  
*
#Mod  
#
**************  
##############  
aa  
current fbus media in hex  
bb  
last sender dev in hex  
cc  
dd  
last sender media in hex  
Next media to be connected. Same as aa if the connection is not pending.  
fbus parity error counter  
fbus framing error counter  
fbus overrun error counter  
fbus alive check counter  
RX Sequence number  
TX Sequence number  
Phone mode: S=slave, H=host  
eee  
fff  
ggg  
hhh  
iii  
jjj  
k
Display 35 – Reasons for SW resets  
**************  
##############  
#Reset reason#  
#Task name #  
*aaaaa  
*
*
*
*
*bbbbbbbb  
*
*
#
#
#
#
**************  
##############  
aaaaa  
last reset reason.  
NORM  
: Probably normal power up.  
: Default value, reset reason is unknown.  
: ASIC watchdog timeout.  
UNKNO  
HW WD  
SWDSP  
SWSIM  
SWIDL  
STACK  
: DSP recovery reset  
: SIM contact failure reset  
: Idle task not running reset  
: Task stack overflow  
bbbbbbbb  
Name of running task before reset.  
Display 36 – Counters for resets  
++++++++++++++  
+ aa bb cc +  
+ dd ee ff +  
+
+
+
+
++++++++++++++  
aa  
bb  
cc  
dd  
ee  
ff  
Unknown resets  
ASIC watchdog resets  
DSP recovery resets  
SIM contact failure resets  
Idle task not running resets  
Task stack overflow resets  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 39 – Information about reasons for call clearing  
++++++++++++++  
+ CC: aaaa +  
+ MM: bbbb +  
+ RR: cccc +  
##############  
#CC CauseValu#  
#MM CauseValu#  
#RR CauseValu#  
+
+
#
#
++++++++++++++  
##############  
aaaa,  
bbbb,  
cccc  
cause code value, see section 10.5/GSM 04.08, '*' is shown if the cause code  
is made up by the respective layer in MS  
CC  
1 unassigned (unallocated) number  
3 no route to destination  
8 operator determined barring  
16 normal call clearing  
17 user busy  
18 no user responding  
19 user alerting, no answer  
21 call rejected  
22 number changed  
27 destination out of order  
28 invalid number format/number incomplete  
31 normal/unspecified  
34 no circuit/channel available  
38 network out of order  
41 temporary failure  
42 switching equipment congestion  
44 requested channel not available  
47 ressource unavailable  
50 requested facility not subscribed  
55 Incoming calls barred within the CUG  
57 bearer capability not authorized  
65 bearer service not implemented  
68 ACM equal to or greater than ACMmax  
69 requested facility not implemented  
88 incompatible destination  
MM  
0 no error  
2 IMSI unknown in HLR  
3 illegal MS  
4 IMSI unknown in VLR  
5 IMEI not accepted  
6 illegal ME  
11 PLMN not allowed  
12 location area not allowed  
13 roaming not allowed in this location area  
17 network failure  
22 network congestion  
32 service option not supported  
33 service option not subscribed  
34 service temporarily out of order  
38 call cannot be identified (call RE)  
RR  
0 normal release  
1 unspecified  
2 channel unacceptable  
3 timer expired  
4 no activity on the radio path  
5 pre-emptive release  
8 handover impossible, timing advance out of range  
9 channel mode unacceptable  
10 frequency not implemented  
65 call already cleared  
97 message type not compatible with protocol state  
101 no cell allocation available  
111 protocol error, unspecified  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Display 40 – Reset handover counters  
**************  
* RESET  
* HANDOVER *  
* COUNTERS *  
##############  
*
# Use menu #  
# to reset #  
# handover #  
# counters #  
##############  
*
*
**************  
With this display all counters of the handover displays can be reset.  
Display 41 (singleband) – Handover display  
++++++++++++++  
+HandOOK: aaa+  
+PrevCh : bbb+  
+HONotOK: ccc+  
+HOIntra: ddd+  
++++++++++++++  
##############  
#HandOvOKCntr#  
#PrevChanCntr#  
#HandOvNOKCnt#  
#HOIntraOKCnt#  
##############  
aaa  
bbb  
ccc  
ddd  
counter for successful handovers (max. amount 999)  
counter for successful back to previous channel attempts  
counter for failed handovers  
counter for successful intracell handovers or assignments  
(max. amount 999)  
Counters will stop when they reach their maximum. To initialize the counters to zero,  
select display 40. Display 60 also initializes these counters.  
Display 41 (dualband) – Handover display, INTER CELL  
++++++++++++++  
+ aaaa bbbb +  
+ cccc dddd +  
+eeefffggghhh+  
+iiijjjkkklll+  
++++++++++++++  
##############  
#G>G InterD>D#  
#G>D OK D>G#  
#InterHoFail #  
# BackToPrev #  
##############  
aaaa  
bbbb  
cccc  
dddd  
counter of successful handovers (max 9999) from GSM900 to GSM900  
counter of successful handovers (max 9999) from GSM1800 to GSM1800  
counter of successful handovers (max 9999) from GSM900 to GSM1800  
counter of successful handovers (max 9999) from GSM1800 to GSM900  
eee  
fff  
ggg  
hhh  
counter for failed handovers (max 999) from GSM900 to GSM900  
counter for failed handovers (max 999) from GSM1800 to GSM1800  
counter for failed handovers (max 999) from GSM900 to GSM1800  
counter for failed handovers (max 999) from GSM1800 to GSM900  
iii  
jjj  
kkk  
lll  
counter of successful back to previous channel attempts (max 999)  
from GSM900 to GSM900  
counter of successful back to previous channel attempts (max 999)  
from GSM1800 to GSM1800  
counter of successful back to previous channel attempts (max 999)  
from GSM900 to GSM1800  
counter of successful back to previous channel attempts (max 999)  
from GSM1800 to GSM900  
Counters will stop when they reach their maximum. To initialize the counters to zero,  
select display 40. Display 60 also initializes these counters.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Display 42 (dualband) – Handover display, INTRA CELL  
++++++++++++++  
+ aaaa bbbb +  
+ cccc dddd +  
+eeefffggghhh+  
+iiijjjkkklll+  
++++++++++++++  
##############  
#G>G IntraD>D#  
#G>D OK D>G#  
#IntraHoFail #  
# BackToPrev #  
##############  
aaa  
bbb  
ccc  
ddd  
counter of successful INTRACELL handovers (max 9999) from GSM900 to GSM900  
counter of successful INTRACELL handovers (max 9999) from GSM1800 to GSM1800  
counter of successful INTRACELL handovers (max 9999) from GSM900 to GSM1800  
counter of successful INTRACELL handovers (max 9999) from GSM1800 to GSM900  
eee  
fff  
ggg  
hhh  
counter of failed INTRACELL handovers (max 999) from GSM900 to GSM900  
counter of failed INTRACELL handovers (max 999) from GSM1800 to GSM1800  
counter of failed INTRACELL handovers (max 999) from GSM900 to GSM1800  
counter of failed INTRACELL handovers (max 999) from GSM1800 to GSM900  
iii  
jjj  
kkk  
lll  
counter of successful back to previous normal INTRA CELL channel attempts  
(max 999) from GSM900 to GSM900  
counter of successful back to previous normal INTRA CELL channel attempts  
(max 999) from GSM1800 to GSM1800  
counter of successful back to previous normal INTRA CELL channel attempts  
(max 999) from GSM900 to GSM1800  
counter of successful back to previous normal INTRA CELL channel attempts  
(max 999) from GSM1800 to GSM900  
Counters will stop when they reach their maximum. To initialize the counters to zero,  
select display 40. Also display 60 initializes these counters.  
Display 43 L2 display  
++++++++++++++  
+T200MS :aaaa+  
+T200BS :bbbb+  
+T200MS :cccc+  
+T200BS :dddd+  
++++++++++++++  
##############  
#T200 MS GSM #  
#T200 BS GSM #  
#T200 MS DCS #  
#T200 BS DCS #  
##############  
aaaa  
bbbb  
cccc  
dddd  
GSM900 : counts how many times T200 in MS has expired and therefore a L2  
transmission has been repeated.  
GSM900 : counts how many times T200 in BS (network) has expired and  
therefore a L2 frame was requested again.  
GSM1800: counts how many times T200 in MS has expired and therefore a L2  
transmission has been repeated. (for dualband phones)  
GSM1800: counts how many times T200 in BS (network) has expired and  
therefore a L2 frame was requested again. (for dualband phones)  
The GSM900 counters are also valid in GSM900/GSM1800 multiband phones. Counters will  
stop when they reach their maximum. To initialize the counters to zero, select  
display 40. Display 60 also initializes these counters.  
Display 44 – Toggle revision level  
**************  
**************  
*
*
*
*
* REVISION *  
*LEVEL IS 00 *  
* REVISION *  
*LEVEL IS 01 *  
*
*
*
*
**************  
**************  
When selected, changes the value of Revision Level from 0 to 1 and vice versa. I have  
no idea if this makes sense in any circumstances.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 45 – Toggle transmitter functionality  
**************  
*
*
*TRANSMITTER *  
* XXXXXXXX *  
XXXXXXXX  
ENABLED or DISABLED  
*
*
**************  
This display has no effect in 7110 phone, irrespective of the displayed status the  
transmitter is always switched on.  
When selected, this display disables transmitter functionality if enabled and vice  
versa. New setting is valid until next power off or until new execute of this  
display.  
This FTD can be used to simulate easily situations when the MS can hear the network  
(i.e. receiving signal is good enough), but the network can not receive any messages  
from the MS.  
Location updating attempts or MO call establishment attempts can be failed (random  
access failure) by this FTD and field testing of these failures is much easier now.  
Next periodic location updating can be checked from the display 10 (chapter 3.1.10)  
by taking the difference of current T3212 counter value and T3212 timeout value.  
Display 51 – SIM information  
++++++++++++++  
+aaa bbb ccc +  
+ dddddddd +  
+ f g hh ii +  
+ j kkkk +  
++++++++++++++  
##############  
#VSel Bau SAl#  
#SCond CStop#  
#PIN12 PUK12#  
# ATR FE/PE #  
##############  
aaa  
bbb  
ccc  
dddd  
f
SIM voltage selection type (5, 3 or 3/5)  
SIM baudrate (372, 64, 32 or 0)  
Clock stop allowed, Yes or No  
Clock stop condition, Up/Down/xxxxxxxx if no preferred level  
PIN1 attempts left (0,1,2,3)  
g
PIN2 attempts left (0,1,2,3)  
hh  
PUK1 attempts left (0-10)  
ii  
PUK2 attempts left (0-10)  
j
ATR retransmission counter (0-9)  
kkkk  
Transmission frame/parity errors, FE/PE + hexadecimal count  
Display 54 – Block display 1  
++++++++++++++  
+aa bb aa bb+  
+aa bb aa bb+  
+aa bb aa bb+  
+aa bb aa bb+  
++++++++++++++  
##############  
#ResF1 ResF2#  
#ResF3 ResF4#  
#ResF5 ResF6#  
#ResF7 ResF8#  
##############  
1. row: Block set 1, block set 2  
2. row: Block set 3, block set 4  
3. row: Block set 5, block set 6  
4. row: Block set 7, block set 8  
aa  
bb  
Number of reserved blocks  
Number of free blocks in worst case  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 55 – Block display 2  
++++++++++++++  
+aa bb aa bb+  
+aa bb aa bb+  
+aa bb aa bb+  
+aa bb aa bb+  
++++++++++++++  
##############  
#ResF9 ResF10#  
#ResF11ResF12#  
#ResF13ResF14#  
#ResF15ResF16#  
##############  
1. row: Block set 9, block set 10  
2. row: Block set 11, block set 12  
3. row: Block set 13, block set 14  
4. row: Block set 15, block set 16  
aa  
bb  
Number of reserved blocks  
Number of free blocks in worst case  
Display 56 – Block display 3  
++++++++++++++  
+ aaaaaa bbb +  
+ cccccccc +  
##############  
# Ptr Cntr #  
# Task  
#
#
#
+
+
+
+
#
#
++++++++++++++  
##############  
aaaaaa  
bbb  
cccccccc  
Pointer to memory where double deallocation was called, in hex format.  
Counter for failed deallocations.  
Name of task which last tried to double deallocate a block.  
Note: This display is only valid when the counter for failed deallocations is not zero.  
Display 57 – Memory status before reset  
++++++++++++++  
+aaaaaaaaaaaa+  
##############  
# Status of #  
+aaaaa...  
+bbbbbbbb  
+
+
+
+
# stacks  
#
# Block sets #  
#
#
++++++++++++++  
##############  
aaaaaa  
Status of each stack before reset. First position contains the status of  
stack 0, second position the status of stack 1 and so on. The last position  
contains the status of System stack. Number of stacks depends on the  
current configuration of SW. Possible values for each stack are:  
0 : status OK, no overflow  
1 : status not OK, stack overflow,  
bbbbbbb  
Status of each block set before reset. First position contains the status  
of block set 1, second position the status of block set 2 and so on.  
Possible values for each block set are:  
0 : status OK  
1 : block set full  
2 : (de)allocation error or total memory corruption  
Note: This display is only valid when a unknown or a stack overflow interrupt has  
occured.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 60 – Reset counters to zero  
**************  
* FIELD TEST *  
* DISPLAY *  
* COUNTERS *  
##############  
#Use menu to #  
#reset field #  
#test display#  
# counters #  
##############  
* RESET  
*
**************  
With this display all counters of the field test display can be reset (i.e. all  
counters in 40 and 60 series).  
On poweroff the values of the counter displays are stored onto the EEPROM, where they  
will be read during power on. To initialize the counters to zero, select display 60.  
These counters are automatically reset to zero when they exceed their maximum value.  
Display 61 – Search and reselection counter display  
++++++++++++++  
+NOPSW :aaaa+  
+SYNCR :bbbb+  
+RESELEC:cccc+  
##############  
#PSWMesgCntr #  
#SyncMeasCntr#  
#CellReselCtr#  
+
+
#
#
++++++++++++++  
##############  
aaaa  
bbbb  
counter for MDI_NO_PSW_FOUND message received from DSP in hexadecimal form.  
counter for synchronization measurement attempts in decimal form. If counter  
value is over 9999 then four x are shown.  
cccc  
counter for cell reselections in hexadecimal form.  
Display 61 (dualband) – Search and reselection counter display  
++++++++++++++  
+aaaaa bbbbb+  
+ccccc ddddd+  
+eeeee fffff+  
+ggggg hhhhh+  
++++++++++++++  
##############  
#NOPswGSM DCS#  
#Sync GSM DCS#  
#reselG>G D>D#  
#reselG>D D>G#  
##############  
aaaaa  
bbbbb  
ccccc  
ddddd  
eeeee  
fffff  
ggggg  
hhhhh  
GSM900 counter for MDI_NO_PSW_FOUND message received from DSP in decimal  
form (max 99999).  
GSM1800 counter for MDI_NO_PSW_FOUND message received from DSP in decimal  
form (max 99999).  
GSM900 counter for synchronization measurement attempts in decimal form. If  
counter value is over 99999 then five x are shown.  
GSM1800 counter for synchronization measurement attempts in decimal form. If  
counter value is over 99999 then five x are shown.  
counter for GSM900 -> GSM900 cell reselections in decimal form (max  
99999).  
counter for GSM1800 -> GSM1800 cell reselections in decimal form (max  
99999).  
counter for GSM900 -> GSM1800 cell reselections in decimal form (max  
99999).  
counter for GSM1800 -> GSM900 cell reselections in decimal form (max  
99999).  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Display 62 – Neighbour measurement counter display  
++++++++++++++  
+ PSW :aaaa +  
+ SYNCR:bbbb +  
+ BCCH :cccc +  
+ BCCHE:dddd +  
++++++++++++++  
##############  
#NeghbrPSWCtr#  
#SyncMeasCntr#  
#BCCHMeasAtmp#  
#BCCHExtMeAtm#  
##############  
aaaa  
bbbb  
cccc  
dddd  
counter for neighbour PSW measurement attempts  
counter for neighbour synchronization measurement attempts  
counter for neighbour BCCH measurement attempts  
counter for neighbour BCCH Ext measurement attempts  
Counter values are shown in hexadecimal form.  
Display 63 – Call attempts counters  
++++++++++++++  
+ aa bb +  
+ ccc ddd +  
+ eee fff +  
##############  
#CalRel RelDi#  
#MOCAtmp MOOK#  
#AllMT MTOK#  
+
+
#
#
++++++++++++++  
##############  
aa  
bb  
Reason of last call release  
Cause from messages DISC and REL_COMP. Refer to TS GSM 04.08/10.5.4.11/Table  
10.86 for further explanation.  
Direction of last call release  
UN : Unknown  
MO : Mobile originated  
MT : Mobile terminated  
IN : Internal (ME CS sw)  
ccc  
ddd  
eee  
fff  
count of all MO call attempts made  
count of succeeded MO calls  
count of all call setups received  
count of succeeded MT calls  
Display 64 – Location Update attempts counters  
++++++++++++++  
+ aa bbb ccc +  
+ dd eee fff +  
##############  
#Nfai NL NLOK#  
#PFai PL PLOK#  
# Loc update #  
# counters #  
##############  
+
+
+
+
++++++++++++++  
aa  
Reason of last normal location update failure  
bbb  
ccc  
dd  
count of normal location update attempts  
count of succeeded normal location updates  
Reason of last periodic or IMSI attach location update failure  
count of all periodic and IMSI attach location update attempts  
count of succeeded periodic and IMSI attach location updates  
eee  
fff  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 65 – SMS attempts counters  
++++++++++++++  
+ aa bbb ccc +  
+ dd eee fff +  
##############  
#SFai MO MOOK#  
#RFai MT MTOK#  
#Sched Msgs #  
#SMS counters#  
##############  
+ gggg  
+
+
+
++++++++++++++  
aa  
Reason of last message sending failure  
1 : Unassigned (unallocated) number  
8 : Operator determined barring  
10 : Call barred  
21 : Short message transfer rejected  
27 : Destination out of service  
28 : Unidentified subscriber  
29 : Facility rejected  
30 : Unknown subscriber  
38 : Network out of order  
41 : Temporary failure  
42 : Congestion  
47 : Resources unavailable, unspecified  
50 : Requested facility not subscribed  
69 : Requested facility not implemented  
81 : Invalid short message transfer reference value  
95 : Invalid message, unspecified  
96 : Invalid mandatory information  
97 : Message type non-existent or not implemented  
98 : Message not compatible with short message protocol state  
99 : Information element non-existent or not implemented  
111 : Protocol error, unspecified  
127 : Interworking, unspecified  
Count of all MO short message attempts  
Count of succeeded MO short message attempts  
Reason of last message receiving failure  
22 : Memory capacity exceeded  
Count of all MT short message attempts  
Count of succeeded MT short message attempts  
Count of all received cell broadcast schedule messages  
bbb  
ccc  
dd  
eee  
fff  
gggg  
Display 66 – SMS timeout counters  
51xx, ++++++++++++++  
61xx: + aaa bbb cc +  
+ ddd eee ff +  
##############  
#TR1 TR2 TRA #  
#TC1 TC2 SCH #  
#SMS timeout #  
# counters #  
##############  
+
+
+
+
++++++++++++++  
7110: ++++++++++++++  
+ aaa bbb +  
##############  
# TR1 TR2 #  
# TRA SCH #  
# TC1 TC2 #  
+ ccc fff +  
+ ddd eee +  
+
+
#
#
++++++++++++++  
##############  
aaa  
bbb  
cc  
ddd  
eee  
ff  
Counter for TR1M timeouts (SMR-Layer: incoming RP-ACK timed out)  
Counter for TR2M timeouts (SMR-Layer: outgoing RP-ACK timed out)  
Counter for TRAM timeouts (RETRANS timer expired)  
Counter for TC1M timeouts (CM-sublayer: CP-ACK timed out)  
Counter for TC2M timeouts (CM-sublayer: )  
Counter for CB schedule timeouts  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Display 70 – Temporary counters of DSP  
++++++++++++++  
+ aaaa bbbb +  
+ cccc dddd +  
+ eeee ffff +  
+ gggg hhhh +  
++++++++++++++  
##############  
# Temporary #  
#DSP counters#  
#(R DSP2FTD) #  
#
#
##############  
aaaa  
bbbb  
cccc  
dddd  
eeee  
ffff  
gggg  
hhhh  
Contents of API memory location r_dsp2ftd+0 in hex format  
Contents of API memory location r_dsp2ftd+1 in hex format  
Contents of API memory location r_dsp2ftd+2 in hex format  
Contents of API memory location r_dsp2ftd+3 in hex format  
Contents of API memory location r_dsp2ftd+4 in hex format  
Contents of API memory location r_dsp2ftd+5 in hex format  
Contents of API memory location r_dsp2ftd+6 in hex format  
Contents of API memory location r_dsp2ftd+7 in hex format  
The display is to be used by special debugging DSP SW which can put some useful  
information to the memory locations on API RAM. When this display is selected then  
MCU copies the contents of those memory locations into display with format specified  
above.  
This display may not be included in normal SW releases.  
Display 71 & 72 – Control DSP audio enhancements 1 & 2  
**************  
*AUDIO  
*ENHANCEMENT *  
*DISPLAY 1/2 *  
##############  
#Use menu to #  
#control DSP #  
*
# audio  
#
*
XXXXX *  
#enhancements#  
##############  
**************  
Caution : playing around with this display may result in (temporary) malfunction of  
the audio path in your phone. Please be careful.  
XXXXX  
Control word for DSP Audio Enhancements in decimal format.  
The control word is sent to the DSP in the MDI_AUDIO_CONFIGURE message.  
Prior using this display the control word must be written to location 31/32 of the  
SIM in decimal format.  
When the display 71/72 is choosen from the menu, (EXECUTE MODE) the control word is  
sent to the DSP in MDI_AUDIO_CONFIGURE message immediately. MDI_AUDIO_CONFIGURE  
message is also sent every time when this display is entered using arrow keys and  
previous display was 72/71.  
Used together with display 72/71, this display makes rapid on/off switching of audio  
DSP algorithms possible. Switching with arrow keys is possible only after this  
display or display 72/71 has been selected from the menu. This prevents accidental  
on/off switching of algorithms when browsing displays by arrow keys.  
Entered values are not saved to EEPROM, so it is possible to reset to the correct  
values by removing the battery.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Display 73 – Generic display for DSP Audio Enhancements  
++++++++++++++  
+ aaa bb aaa+  
+cccc bb cccc+  
+cccc bb cccc+  
+ cccc cccc +  
++++++++++++++  
Example: ++++++++++++++  
+ 101 00 408+  
##############  
#DB1 B1 DB2#  
#HEX1 B2 HEX2#  
#HEX3 B3 HEX4#  
# HEX5 HEX6 #  
##############  
+BCDE 88 7FFF+  
+0001 FF 0003+  
+ DEAD DEFA +  
++++++++++++++  
aaa  
General dB value, e.g. signal level in dB.decimal point and sign is not  
shown, ie. -10.5 is show 105.  
General byte value, used for combined flags. Value is in hex format.  
General hex value.  
bb  
cccc  
The display is reset and restarted when call is taken (if FT display counters are  
enabled). When call is terminated the display is frozen to show last values. Display  
values will not be saved to the EEPROM.  
Display 74 – DSP audio enhancements 1 (DRC)  
++++++++++++++  
+ aaa bbb +  
Example: ++++++++++++++  
+ 101 408 +  
##############  
#DSigL USigL #  
+
ccc +  
ee +  
+
+
480 +  
03 +  
+
#
NseLvl#  
+ dd  
+
+ 01  
+
# DTbl UTbl #  
#
#
++++++++++++++  
++++++++++++++  
##############  
aaa  
bbb  
ccc  
Downlink signal level in dB, calculated using DRC level measuring block.  
Decimal point and sign is not shown, ie. -10.5 is show 105.  
Uplink signal level in dB, calculated using DRC level measuring block.  
Decimal point and sign is not shown, ie. -10.5 is show 105.  
Background noise signal level in dB, calculated using DRC level measuring  
block, decimal point and sign is not shown, ie. -10.5 is show 105.  
Downlink DRC table value, shown in decimal integer, two digits.  
Uplink DRC table value, decimal integer, two digits.  
dd  
ee  
The display is reset and restarted when call is taken (if FT display counters are  
enabled). When call is terminated the display is frozen to show last values. Display  
values will not be saved to the EEPROM.  
Display 75 – Audio path status  
++++++++++++++  
+Mod:aaaaaaaa+  
+AudReq: bbbb+  
+AccMod: cccc+  
+H2Path: dd +  
++++++++++++++  
##############  
#ExtAudStatus#  
#AudioRequest#  
#AccessoryMod#  
#HFU2Path  
#
##############  
aaaaa  
bbbb  
cccc  
dd  
external audio status, values are: HP, HF, HEADSET, EXT and HP_OFFHO  
audio_request bitmap in hex, contents (masks) are specified in AUD_DATA.H  
Accessory audio mode  
HFU-2 path  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 76 – Ear (= downlink) audio display  
++++++++++++++  
+ Vaa Pbbb +  
+ Cccc CAddd +  
Example: ++++++++++++++  
##############  
#EVol PeakVal#  
#CutOff COAve#  
+ V0A P125 +  
+ C000 CA001 +  
+PAeee  
+
+
+
+PA353  
+
+
+
#PkAver  
#
#
#
++++++++++++++  
++++++++++++++  
##############  
aa  
bbb  
Volume level.  
Peak value of downlink audio signal during last frame in dB, decimal point  
and sign is not shown, ie. -10.5 is show 105.  
ccc  
ddd  
eee  
Cut off counter value of last frame. This counter counts how many samples  
are saturated during last frame.  
Moving average of cut off counter, decimal point and sign is not shown, ie.  
-10.5 is show 105.  
Moving average of peak levels.  
The display is reset and restarted when call is taken (if FT display counters are  
enabled). When call is terminated the display is frozen to show last values. Display  
values will not be saved to the EEPROM.  
Display 77 – Microphone (= uplink) audio display  
++++++++++++++  
+ Paaa Abbb +  
+ Cccc CAddd +  
Example: ++++++++++++++  
+ P303 A225 +  
##############  
#MicPeak MAve#  
#CutOff COAve#  
+ C023 CA003 +  
+
+
+
+
+
+
+
+
#
#
#
#
++++++++++++++  
++++++++++++++  
##############  
aaa  
bbb  
ccc  
ddd  
Peak value of uplink audio signal during last frame in dB decimal point and  
sign is not shown, ie. -10.5 is show 105.  
Moving average of peak levels, decimal point and sign is not shown, ie. -  
10.5 is show 105.  
Cut off counter value of last frame. This counter counts how many samples  
are saturated during last frame.  
Moving average of cut off counter  
The display is reset and restarted when call is taken (if FT display counters are  
enabled). When call is terminated the display is frozen to show last values. Display  
values will not be saved to the EEPROM.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 78 – DSP audio enhancements (AEC)  
++++++++++++++  
+aaa bbb ccc +  
+ddd eee fff +  
+ggg h i jjj +  
+ kkkk llll +  
++++++++++++++  
##############  
#EAA Ada ERL #  
#RxG TxG GLi #  
#TxN Sta Mod #  
# RVAD TVAD #  
##############  
Decimal point and sign are not shown in values. This means:  
-10.5dB would be displayed as "105"  
-0.5 dB would be displayed as " 5"  
aaa  
bbb  
ccc  
ddd  
eee  
fff  
ggg  
h
Electro-acoustic attenuation of echo from DSP point of view in dB  
Adaptive attenuation of echo  
Total echo return loss  
RX attenuator gain in dB  
TX attenuator gain in dB  
Gain limit for RX and TX  
Tx noise level in dB  
Adaptive filter status (0 or 1)  
Comfort noise generation (0 or 1)  
AEC mode (0 or 1)  
I
jjj  
kkkk  
Llll  
Shows 16 last RX VAD decisions in HEX format  
Shows 16 last TX VAD decisions in HEX format  
Display 79 – Audio equalizer display  
++++++++++++++  
+aaaaa bbbbb +  
+ccccc ddddd +  
+-ee.e -ff.f +  
Example: ++++++++++++++  
##############  
#MiCutB MiCTA#  
#EpCutB EPCTA#  
#MicLev EarLv#  
+12345 54321 +  
+ 2353 46187 +  
+-46.5 -27.4 +  
+
+
+
+
#
#
++++++++++++++  
++++++++++++++  
##############  
aaaaa  
bbbbb  
ccccc  
ddddd  
-ee.e  
-ff.f  
Saturated samples before microphone equalizer in decimal 16 bit unsigned  
integer format.  
Saturated samples after microphone equalizer in decimal 16 bit unsigned  
integer format.  
Saturated samples before earpiece equalizer in decimal 16 bit unsigned  
integer format.  
Saturated samples after earpiece equalizer in decimal 16 bit unsigned  
integer format.  
Level of the microphone signal level detector in dB format.  
Requires log10 function in MCU. 16 bit signed value in DSP, 0 dB = 32768.  
Level of the signal after earpiece equalizer in dB format.  
Requires log10 function in MCU. 16 bit signed value in DSP, 0 dB = 32768.  
The display is reset and restarted when a call is placed. When the call is terminated  
the display is frozen to show the last values. Display will not be saved to EEPROM.  
Saturated sample counters aaaaa - ddddd are counted in DSP and only the new counter  
value is sent to MCU. The microphone and earpiece signal levels are calculated in DSP  
and it sends the linear values to MCU which makes the linear to dB transformation  
(20*log10(x)) for the level values.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 80 – Reset and restart timers  
**************  
##############  
*
*
# Use menu #  
# to reset #  
# field test #  
# timers #  
##############  
* TIMERS *  
* RESET  
*
*
*
**************  
With this display all timers of display 82 can be reset.  
These timers will be automatically reset after the battery has been fullycharged and  
the charger is disconnected. Thus it's not always necessary to use the display 80.  
Display 81 – Enable or disable timers  
**************  
*
*
* TIMERS *  
* XXXXXXXX * XXXXXXXX := ENABLED or DISABLED  
*
*
**************  
This display will start or stop the timers.  
On power off the values of the timer displays are stored onto the EEPROM, where they  
will be read during power on. To initialize the counters to zero, use display 80.  
Timers will be automatically disabled when recharge battery message is reached.  
Also the current state of timer disabling/enabling is stored onto the EEPROM.  
Display 82 – Test timer display  
++++++++++++++  
+aaaaa bbbbb +  
+ccccc ddddd +  
+ TIMERS eee +  
##############  
#PwrOn InServ#  
#NSPS TxON #  
# Timers #  
# Status #  
##############  
+
+
++++++++++++++  
aaaaa  
bbbbb  
ccccc  
ddddd  
eee  
timer for how long the phone has been powered on  
timer for how long the phone has been in service  
timer for 'no service, power save'-state  
timer for how long the transmitter has been on  
state of timers, ON/OFF  
All the values are shown in one minute resolution. The accuracy of the timers is  
about one second. The display uses following format for timers:  
HHHMM where HHH is hours and MM is minutes.  
All timers of this display will be reset if the charger is disconnected from the  
mobile with fully charged battery. The maximum value of the timers is 99 h 59 min.  
When 'powered on' timer has reached value 9959, all timers will be stopped.  
NOTE: When the maxium usage time of the phone is required (e.g. idle time  
measurement) then ALL field test displays must be deactivated!  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Display 83 – Control of task information displays  
**************  
*
*
* SHOW TASK *  
* XXXXXXXXX * XXXXXXXXX is "STACKS", "MSG BUFS" or "FAST BUFS"  
*
*
**************  
Shows what information about tasks is currently shown in displays 84 - 87.  
To select the type of information select this display via menu.  
Type is changed in order STACKS -> MSG BUFS -> FAST BUFS -> STACKS.  
So, if STACKS is currently displayed and you want to see FAST BUFS, you have to  
select this display twice via menu.  
"STACKS"  
"MSG BUFS"  
"FAST BUFS"  
shows free stack space in worst case.  
shows the peak number of pending messages.  
shows the peak number of pending fast messages.  
Display 84, 85 & 86 – Information about tasks  
++++++++++++++  
+ aaaa bbbb +  
+ cccc dddd +  
+ eeee ffff +  
+ gggg hhhh +  
++++++++++++++  
aaaa  
bbbb  
cccc  
dddd  
eeee  
ffff  
gggg  
hhhh  
task 0, 8, 16  
task 1, 9, 17  
task 2, 10, 18  
task 3, 11, 19  
task 4, 12, 20  
task 5, 13, 21  
task 6, 14  
task 7, 15  
The numbers are showing how many stack memory locations have been empty in the worst  
case. So, if number is zero, stack has been full.  
Values are not stored to EEPROM when the phone is powered off.  
The task names are listed on the help display.  
Display 87 – Information about OS_SYSTEM_STACK  
++++++++++++++  
+ aaaa bbbb +  
##############  
# FIQ IRQ #  
+
+
+
+
+
+
#
#
#
#
#
#
++++++++++++++  
##############  
aaaa  
OS_SYSTEM_STACK. No clue what this means.  
Values are not stored to EEPROM.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 88 – Information of the current MCU and DSP software versions  
**************  
*aaaaa bbbbbb*  
*Date cccccc*  
*ChkSum dddd *  
*eeeeeeeeeeee*  
**************  
##############  
#MCUSW PPM #  
#MCUSW_Date #  
#MCU_Checksum#  
#DSP_Version #  
##############  
aaaaa  
version number of MCU SW  
PPM version  
date of version.c (e.g. 990102 means 02. January 1999)  
MCU SW checksum  
version of DSP software  
bbbbbb  
cccccc  
dddd  
eeeeeeeeeeee  
Display 88 (9210) – Version information for organizer part  
**************  
*Linda SW  
*aaaaa bbbbbb*  
*ChkSum: cccc*  
##############  
#Linda SW  
#Version Date#  
#Checksum  
#HW Version #  
##############  
*
#
#
*HW: dddd  
*
**************  
aaaaa  
organizer module firmware version  
organizer module firmware date code  
organizer module firmware checksum  
organizer module hardware version  
bbbbb  
cccc  
dddddd  
Display 89 – Information of the current HW and TXT versions  
**************  
*HW: aaaa  
*TXT:bbbbbbb *  
##############  
#HW Version #  
#Text Version#  
*
*
*
*
*
#
#
#
#
**************  
##############  
aaaaa  
bbbbbb  
Hardware version (e.g. 2350)  
Text version (e.g. U190199)  
Display 89 (9210) – Version information for phone part  
**************  
*CMT SW  
*aaaaa bbbbb *  
*PPM: cccccc*  
##############  
#CMT SW  
#Version Date#  
#PPM Version #  
#DSP Version #  
##############  
*
#
*dddddddd  
*
**************  
aaaaa  
phone module firmware version  
phone module firmware date code  
PPM software version code  
bbbbb  
cccccc  
dddddd  
DSP software version code  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 96 (3210) – receiver temperature  
3210  
**************  
*VCX0ADC: aaa*  
*TEMP(C): bb*  
*TEMP(K): ccc*  
##############  
#ADC VALUE #  
#RF TEMP(C) #  
#RF TEMP(K) #  
*
*
#
#
**************  
##############  
bb  
ccc  
receiver temperature in degrees C  
same value, but in K  
Display 99 (7110) – FBUS mode and Accessory mode  
7110: **************  
* Ead:aaaa *  
##############  
# EAD value #  
# acc.status #  
# FBUS mode #  
* Mod:bb  
*
* MODE: cccc *  
*
*
#
#
**************  
##############  
aaaa  
bb  
cccc  
no clue  
type of connected accessory (HP: Headphone, DC: Datacable)  
currently selected data transfer mode (FBUS, MBUS, AT)  
Display 100 (7110, 62XX) – Internal memory usage, overview  
7110, **************  
62XX: *aaaaaa bb.c*  
*cccccc dd.d*  
##############  
#MemUseT %Use#  
#MemRelT %Rel#  
#MemUnuT %Unu#  
*eeeeee ff.f*  
*
*
#
#
**************  
##############  
aaaaaa  
the total amount of used memory in the phone  
bb.b  
the used percentage of the phones internal memory (% used)  
(phonebook, tasks, calendar, logos, ring tones etc.)  
the total amount of released memory in the memory pool  
the percentage of memory which was used, but is currently released  
the total amount of free memory in the phone  
cccccc  
dd.d  
eeeeee  
ff.f  
the amount of free memory available (% not used)  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Display 102 (9210) – last data call type  
9210  
**************  
*Data call *  
##############  
#Data call #  
*type:  
*aaaaaa  
*
*
*
*
#type  
#
#
#
#
#
**************  
##############  
aaaaaa  
type of the last successful data call  
Display 103 (9210) – last MT call type  
9210  
**************  
*Incoming  
*call type: *  
##############  
#Incoming  
#call type #  
*
#
*aaaaaa  
*
*
*
#
#
#
#
**************  
##############  
aaaaaa  
type of the last successful MT call  
Display 107 (62XX) – Voice dialling feature  
62XX  
**************  
*ND a b c *  
##############  
#ND mm cs ps #  
# ss po da #  
#Ver Date #  
*
d e f *  
*ggggg hhhhhh*  
*
*
#
#
**************  
##############  
a
b
c
number of recorded voice tags currently in phone  
no clue  
status of the voice dialler  
0 – not initialized  
1 – last VT not recognized  
5 – last VT recognized  
7 – Voice dialling cancelled  
8 – in use  
Display 110 to 115 (7110, 62XX) – Internal memory usage, detail  
7110, **************  
62XX: * a bbbbccccc*  
*dddddd eeeee*  
##############  
#Pn Sta %Use#  
#EraseCn %Rel#  
#NextRec %Unu#  
#Cu Cl Cc MmC#  
##############  
*ffffff ggggg*  
*h i j kkkk *  
**************  
a
the number of the current memory bank  
bbbb  
shows wether this bank is used (0xFFF8)  
or free (7110: 0xfffe, 62XX: 0xfff0)  
ccccc  
ddddd  
eeeee  
ffffff  
ggggg  
percentage of memory used in this bank  
erase counter for bank (significant when using flash memory)  
percentage of memory which is released in this bank  
memory location of next free record  
percentage of memory available in this bank  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 130 (7110) – Slide open counter  
7110: **************  
##############  
#Slide Open#  
*aaa  
bbbbb*  
*
*
*
*
*
*
#
#
#
#
#
#
**************  
##############  
bbbbb  
shows how many times the slide has been opened. The value is shown  
in hexadecimal digits.  
Display 132 (3310) – Call information  
3310: **************  
*BS: aaaaaaaa*  
*MO: bbbbbbbb*  
*DRC:cccccccc*  
*TIM:dddddddd*  
**************  
##############  
#BS_Call Cnt #  
#MO_Call cnt #  
#Dropped call#  
#Call time #  
##############  
aaaaaaaa  
bbbbbbbb  
cccccccc  
dddddddd  
the total number of received (MT) calls  
the total number of placed (MO) calls  
the total number of dropped calls  
the accumulated call time in seconds of all calls  
Display 133 (3310) – Charger information  
3310: **************  
*BFu:aaaaaaaa*  
##############  
#FullChargCnt#  
#ChaCon Wrong#  
#Standby time#  
# NoServTimer#  
##############  
*ChC:bbbb cc*  
*StB:  
*NSe:  
*
*
**************  
aaaaaaaa  
shows how many times the ‘Battery Full’-message has been displayed  
whilst the phone was activated  
bbbb  
cc  
shows how often the charger was correctly connected and recognized  
by the phone. The value is increased either when the charger is  
recognized or when the charger is inserted, the phone is in a  
charging state and is switched on  
number of times a wrong or defective charger was identified  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display 240 (no output) – Clear counters and start timers  
This Display has no output, but does the following when directly selected:  
Resets…  
…handover counters (display 40 ff.),  
…test counters  
…timers  
(display 60 ff.) and  
(display 80 ff.)  
and starts the test counters from display 81.  
Display 241 (no output) – Disable the netmonitor menu  
This Display has no output, but does the following when directly selected:  
Disables the netmonitor menu.  
Note: Every display number which results in 241 from MOD 256 will deactivate the  
netmonitor menu, so display 497 and display 753 will do the same. There is absolutely  
no such feature like sending SMS for free or to make free calls for 90 seconds.  
To reactivate the netmonitor menu, you may want to  
- use Logomanager  
- use NetMonitor from A. Schmidt  
- use TAPIR-G from Nobbi  
- use GNOKII  
- use PCLocals from Nokia  
Display 242 (no output) – Disable R&D field test displays  
This Display has no output, but does the following when directly selected:  
Disables R&D filed test displays, but leaves the netmonitor displays (1..19) active,  
so you will have only a limited netmonitor activated.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Nady Systems Stereo System SD 2418 User Manual
Niles Audio Home Theater System SW65 User Manual
Niles Audio Stereo Receiver SCW 1D User Manual
Nuvo Stereo System NV I8GMS NV I8GXS User Manual
Oki Printer C8600 User Manual
Olympus Camcorder XZ 1 User Manual
Omnimount TV Mount POWER 40 User Manual
Panasonic Answering Machine KX TG1837AL User Manual
Panasonic Fax Machine KX PW777E3 User Manual
Panasonic Handheld Game System FZ 10 User Manual