National Instruments Network Card NI 9403E User Manual

OPERATING INSTRUCTIONS AND SPECIFICATIONS  
NI 9403E  
32-Channel, TTL Digital Input/Output Module  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NI 9403E Dimensions  
The following figure shows the dimensions of the NI 9403E.  
73.4 (2.89)  
0.0 (0.00)  
Figure 1. NI 9403E Dimensions in Millimeters (Inches)  
© National Instruments Corp.  
3
NI 9403E Operating Instructions and Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting the NI 9403E  
The NI 9403E has a 37-pin DSUB connector that provides  
connections for the 32 digital input/output channels.  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
DIO0  
DIO1  
DIO2  
DIO3  
DIO4  
DIO5  
DIO6  
DIO7  
COM  
COM  
DIO8  
DIO9  
DIO10  
DIO11  
DIO12  
DIO13  
DIO14  
DIO15  
RSVD  
DIO16  
DIO17  
DIO18  
DIO19  
DIO20  
DIO21  
DIO22  
DIO23  
COM  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
COM  
DIO24  
DIO25  
DIO26  
DIO27  
DIO28  
DIO29  
DIO30  
DIO31  
Figure 2. NI 9403E Pin Assignments  
NI 9403E Operating Instructions and Specifications  
4
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Each channel has a DIO pin to which you can connect a digital  
input or output device. The 32 DIO channels are internally  
referenced to COM, so you can use any of the four COM lines as a  
reference for the external signal.  
You can independently configure each DIO channel in software for  
input or output. The DIO channels have Schmitt trigger inputs and  
are compatible with 5 V TTL logic devices. Each input channel  
has hysteresis for improved performance with noisy and  
non-monotonic input signals. Each channel also has a pull-down  
resistor and includes overvoltage, overcurrent, and short-circuit  
protection. Refer to the Specifications section for more information  
about input thresholds and overvoltage protection. Refer to the  
Overcurrent/Short-Circuit Protection section for more  
information about overcurrent and short-circuit protection.  
© National Instruments Corp.  
5
NI 9403E Operating Instructions and Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Refer to Figure 3 for an illustration of several types of digital  
devices connected to the NI 9403E.  
DIO0 as Input  
TTL Signal  
Dev 1  
DIO1 as Input  
COM  
+5 V  
Dev 2  
+5 V  
LED  
DIO2 as Output  
Dev 3  
NI 9403E  
Figure 3. Connecting Digital Devices to the NI 9403E  
NI 9403E Operating Instructions and Specifications  
6
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Overcurrent/Short-Circuit Protection  
The overcurrent protection allows only a specified amount of  
current through the output channels to protect the NI 9403E from  
short circuits. If the NI 9403E goes into an overcurrent state, the  
module sets all the DIO channels to high impedance for  
approximately 280 milliseconds. When the channels are in this  
state, the NI 9403E can accept new line direction configuration and  
output state data but cannot pass valid input data to the software.  
After the protection period, the NI 9403E automatically recovers to  
the latest direction configuration and output state. If the  
overcurrent condition still exists, the module again sets the  
channels to high impedance. This cycle continues until the  
overcurrent condition is removed. Refer to the Specifications  
section for more information about the maximum output current.  
Sleep Mode  
This module supports a low-power sleep mode. Support for sleep  
mode at the system level depends on the chassis that the module is  
plugged into. Refer to the chassis manual for information about  
support for sleep mode. If the chassis supports sleep mode, refer to  
the software help for information about enabling sleep mode. Visit  
© National Instruments Corp.  
7
NI 9403E Operating Instructions and Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ni.com/info and enter cseriesdoc for information about  
C Series documentation.  
Typically, when a system is in sleep mode, you cannot  
communicate with the modules. In sleep mode, the system  
consumes minimal power and may dissipate less heat than it does  
in normal mode. Refer to the Specifications section for more  
information about power consumption and thermal dissipation.  
Specifications  
The following specifications are typical for the range –40 to 85 °C  
unless otherwise noted. All voltages are relative to COM unless  
otherwise noted.  
Input/Output Characteristics  
Number of channels..........................32 DIO channels  
Input/output type...............................TTL, single-ended  
Default power-on line direction........Input  
NI 9403E Operating Instructions and Specifications  
8
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Digital logic levels  
Input  
Voltage .................................0.25 to 5.25 V  
High, VIH..............................2.2 V min  
Low, VIL ...............................0.8 V max  
Hysteresis, VH......................0.2 V min  
Output  
High, VOH.............................5.2 V max  
Sourcing 100 μA ...........4.75 V min  
Sourcing 2 mA...............4.4 V min  
Low, VOL  
Sinking 100 μA .............0.1 V max  
Sinking 2 mA.................0.26 V max  
Input current (0 V Vin 4.5 V)...... 250 μA max  
Module output current1.....................64 mA max  
Input capacitance ..............................30 pF  
1 Module output current is the maximum guaranteed current that the module can drive  
from all the I/O lines without going into an overcurrent state.  
© National Instruments Corp.  
9
NI 9403E Operating Instructions and Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Timing  
Input  
Setup time1...........................10 ns min  
Hold time2 ............................60 ns min  
Output  
Propagation delay3 ...............330 ns max  
Channel-to-channel skew4 ...265 ns max  
1 Setup time is the amount of time input signals must be stable before reading from the  
module.  
2
Hold time is the amount of time input signals must be stable after initiating a read  
from the module.  
3
Propagation delay is the amount of time after writing to the module that the output  
signals become valid.  
4
Channel-to-channel skew is the amount of time between the first output signal  
updating and the last output signal updating.  
NI 9403E Operating Instructions and Specifications 10  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Update/transfer time1  
cRIO-9151 R Series  
Expansion chassis ................8 μS max  
All other chassis...................7 μS max  
Direction change time1 ...............18 μS max  
Overvoltage protection  
Channel-to-COM.............................. 30 V max on up to  
8 channels at a time;  
however, continued use at  
this level will degrade the life  
of the module.  
1 The update/transfer and direction change times are valid when the module is used in  
a CompactRIO system. When used in other systems, driver software and system  
latencies impact these times.  
© National Instruments Corp.  
11 NI 9403E Operating Instructions and Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MTBF ...............................................763,325 hours at 25 °C;  
Bellcore Issue 2, Method 1,  
Case 3, Limited Part Stress  
Method  
Note Contact NI for Bellcore MTBF specifications  
at other temperatures or for MIL-HDBK-217F  
specifications.  
Power Requirements  
Power consumption from chassis  
Active mode ...............................1 W max  
Sleep mode .................................25 μW max  
Thermal dissipation (at 70 °C)  
Active mode ...............................1 W max  
Sleep mode .................................25 μW max  
NI 9403E Operating Instructions and Specifications 12  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Physical Characteristics  
If you need to clean the module, wipe it with a dry towel.  
Weight...............................................47 g (1.7 oz)  
Safety  
Safety Voltages  
Connect only voltages that are within the following limits.  
Channel-to-COM.............................. 30 V max on up to  
8 channels at a time,  
Measurement Category I  
Isolation  
Channel-to-channel ....................None  
Channel-to-earth ground  
Continuous...........................60 VDC,  
Measurement Category I  
Withstand .............................1,000 Vrms, verified by a 5 s  
dielectric withstand test  
© National Instruments Corp.  
13 NI 9403E Operating Instructions and Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Measurement Category I is for measurements performed on  
circuits not directly connected to the electrical distribution system  
referred to as MAINS voltage. MAINS is a hazardous live electrical  
supply system that powers equipment. This category is for  
measurements of voltages from specially protected secondary  
circuits. Such voltage measurements include signal levels, special  
equipment, limited-energy parts of equipment, circuits powered by  
regulated low-voltage sources, and electronics.  
Caution Do not connect the NI 9403E to signals or use  
for measurements within Measurement Categories II,  
III, or IV.  
Safety Standards  
This product meets the requirements of the following standards of  
safety for electrical equipment for measurement, control, and  
laboratory use when installed in a suitable enclosure:  
IEC 61010-1, EN 61010-1  
UL 61010-1, CSA 61010-1  
Note For UL and other safety certifications, refer to the  
product label or the Online Product Certification section.  
NI 9403E Operating Instructions and Specifications 14  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Online Product Certification  
Refer to the product Declaration of Conformity (DoC) for  
additional regulatory compliance information. To obtain product  
certifications and the DoC for this product, visit ni.com/  
certification, search by module number or product line, and  
click the appropriate link in the Certification column.  
Environmental  
National Instruments C Series modules are intended for indoor use  
only but may be used outdoors if installed in a suitable enclosure.  
Refer to the manual for the chassis you are using for more  
information about meeting these specifications.  
Operating temperature  
(IEC 60068-2-1, IEC 60068-2-2) .....40 to 85 °C  
Storage temperature  
(IEC 60068-2-1, IEC 60068-2-2) .....40 to 85 °C  
Operating humidity  
(IEC 60068-2-56)..............................10 to 90% RH,  
noncondensing  
Storage humidity  
(IEC 60068-2-56)..............................5 to 95% RH,  
noncondensing  
© National Instruments Corp.  
15 NI 9403E Operating Instructions and Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Maximum altitude.............................2,000 m  
Pollution Degree (IEC 60664)..........2  
Environmental Management  
NI is committed to designing and manufacturing products in an  
environmentally responsible manner. NI recognizes that  
eliminating certain hazardous substances from our products is  
beneficial to the environment and to NI customers.  
For additional environmental information, refer to the NI and the  
Environment Web page at ni.com/environment. This page  
contains the environmental regulations and directives with which  
NI complies, as well as other environmental information not  
included in this document.  
NI 9403E Operating Instructions and Specifications 16  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Waste Electrical and Electronic Equipment (WEEE)  
EU Customers At the end of the life cycle, all products  
must be sent to a WEEE recycling center. For more  
information about WEEE recycling centers and National  
Instruments WEEE initiatives, visit ni.com/  
environment/weee.  
⬉ᄤֵᙃѻક∵ᶧ᥻
ㅵ⧚
⊩ ˄Ё೑  
˅
RoHS  
ヺড়Ё೑⬉ᄤֵᙃ  
Ё೑ᅶ᠋  
National Instruments  
ѻકЁ䰤
Փ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ  
DŽ݇Ѣ  
(RoHS)  
Ё೑  
ড়㾘ᗻֵᙃˈ䇋ⱏᔩ  
RoHS  
National Instruments  
ni.com/environment/rohs_chinaDŽ  
about China RoHS compliance, go to  
environment/rohs_china  
(For information  
ni.com/  
.)  
© National Instruments Corp.  
17 NI 9403E Operating Instructions and Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Where to Go for Support  
The National Instruments Web site is your complete resource for  
technical support. At ni.com/support you have access to  
everything from troubleshooting and application development  
self-help resources to email and phone assistance from  
NI Application Engineers.  
National Instruments corporate headquarters is located at  
11500 North Mopac Expressway, Austin, Texas, 78759-3504.  
National Instruments also has offices located around the world to  
help address your support needs. For telephone support in the  
United States, create your service request at ni.com/support  
and follow the calling instructions or dial 512 795 8248. For  
telephone support outside the United States, contact your local  
branch office:  
Australia 1800 300 800, Austria 43 662 457990-0,  
Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599,  
Canada 800 433 3488, China 86 21 5050 9800,  
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00,  
Finland 358 (0) 9 725 72511, France 01 57 66 24 24,  
Germany 49 89 7413130, India 91 80 41190000,  
Israel 972 3 6393737, Italy 39 02 41309277, Japan 0120-527196,  
NI 9403E Operating Instructions and Specifications 18  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28,  
Malaysia 1800 887710, Mexico 01 800 010 0793,  
Netherlands 31 (0) 348 433 466, New Zealand 0800 553 322,  
Norway 47 (0) 66 90 76 60, Poland 48 22 3390150,  
Portugal 351 210 311 210, Russia 7 495 783 6851,  
Singapore 1800 226 5886, Slovenia 386 3 425 42 00,  
South Africa 27 0 11 805 8197, Spain 34 91 640 0085,  
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151,  
Taiwan 886 02 2377 2222, Thailand 662 278 6777,  
Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545  
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the  
Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other  
product and company names mentioned herein are trademarks or trade names of their respective companies.  
For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software,  
the patents.txt file on your media, or ni.com/patents.  
© 2008 National Instruments Corp. All rights reserved.  
372617A-01  
Jul08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

MTD Trimmer YM26CO YM26CS YM26SS YM26BC User Manual
NAD Stereo System T760 User Manual
National Instruments Network Card FP 1000 User Manual
National Instruments Network Card NI 8171 Series User Manual
NETGEAR Switch JGS524NA User Manual
NeumannBerlin Microphone M 49c User Manual
Nextar MP3 Player MA968 User Manual
Niles Audio Home Theater System HT MSU User Manual
Nilfisk ALTO Vacuum Cleaner 965 0H M SD XC User Manual
Palm Laptop Handheld Users User Manual