NCR Work Light 7455 User Manual

NCR 7455 Retail Terminal  
Release 1.0  
Site Preparation  
18427  
B005-0000-1286  
Issue A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Site Preparation  
i
Preface  
Audience  
This book is written for hardware installer/ service personnel, system  
integrators, and field engineers.  
Notice: This document is NCR proprietary information and is not to  
be disclosed or reproduced without consent.  
Safety Warnings  
This equipment is intended for use with an IT power system with a line-to-  
line voltage of 240 V or less.  
Fuse Replacement  
Caution: For continued protection against risk of fire, replace only  
with the same type and ratings of fuse.  
Attention: Pour prévenir et vous protéger contre un risque de feu,  
remplacer la fusible avec une autre fusible de même type, seulement.  
Power Supply Cord Used as Disconnect Means  
Caution: The power supply cord is used as the main disconnect  
device. Ensure that the socket outlet is located/ installed near the  
equipment and is easily accessible.  
Attention: Le cordon d'alimentation est utilisé comme interrupteur  
général. La prise de courant doit être située ou installée å proximité du  
matériel et être facile d'accés.  
Warning: DO NOT connect or disconnect the transaction printer  
while the terminal is powered on. This can result in system or printer  
damage.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ii  
Site Preparation  
Lithium Battery Warning  
Caution: Danger of explosion if battery is incorrectly replaced.  
Replace only with the same or equivalent type as recommended by the  
manufacturer. Discard used batteries according to the manufacturer's  
instructions.  
Attention: Il y a danger d'explosion s'il y a remplacement incorrect de  
la batterie. Remplacer uniquement avec une batterie du même type ou  
d'un type recommandé par le constructeur. Mettre au rébut les  
batteries usagées conformément aux instructions du fabricant.  
Peripheral Usage  
This terminal should only be used with peripheral devices that are  
certified by the appropriate safety agency for the country of installation  
(UL, CSA, TUV, VDE) or those which are recommended by NCR  
Corporation.  
Environmental Consciousness  
NCR is demonstrating its concern for the environment by designing an  
intelligent power management system into this terminal that operates  
efficiently whether the system is in a stand-alone or network  
environment.  
About this Book  
This book provides site preparation information for terminal  
components. Peripheral component and AC wiring site preparation  
information is NOT provided in this book. The associated reference  
documents are listed in the “Related Site Preparation Data” section.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Site Preparation  
iii  
This book contains the information necessary for the preparation of a  
site that conforms to NCR specifications. It is very important that the  
site complies with the requirements specified in the document because,  
once the equipment has been installed, deficiencies in site preparation  
or the problems caused by these deficiencies are much more difficult to  
detect and correct. Further, failure to comply with these requirements  
or to take proper steps to protect equipment against risks identified in  
this document may cause serious damage to the equipment and to the  
customers business.  
In addition to the need to comply with the requirements specified,  
electrical wiring and mechanical systems must also comply with all  
relevant codes, laws, and regulations.  
It is important that a customer or his agent who is fully conversant  
with the special requirements of electronic equipment prepare the site.  
The responsibility of ensuring that the site is prepared in compliance  
with this document remains with the customer.  
For information and guidance purposes only, a list is provided, in  
general terms, of those matters for which the customer is responsible.  
This list is not intended to be comprehensive, and in no way modifies,  
alters, or limits the responsibility of the customer for all aspects of  
adequate site preparation.  
NCR staff will be available to answer questions relating to the contents  
of this document except where:  
A customer has been notified that a full or partial consultant service  
is available and/ or that NCR will be willing to undertake a  
preliminary or final site survey and  
The customer shall have entered into a formal contract with NCR  
for provision of the same.  
No comment, suggestion, or advice offered or not offered about  
preparation of the site, nor any inspection of the site, whether before of  
after preparation, is to be taken as approval of the location of the site  
and equipment or its preparation. NCR will not be liable in respect to  
any comment, suggestion, or advice given by its staff or in respect to  
any failure to give advice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iv  
Site Preparation  
Finally, only the customer can know the full extent of damage that may  
be caused to his business by reason of failure of the equipment which is  
to be installed. For this reason, it is the customers responsibility to  
ascertain the extent of any possible damage to his existing or planned  
business, and to effect full insurance in for all eventualities.  
References  
NCR 7455 Retail Terminal User’s Guide  
(B005-0000-1285)  
NCR 7455 Retail Terminal Service Guide  
(B005-0000-1339)  
NCR FitClient User's Guide  
(B005-0000-1235)  
NCR 7455 Retail Terminal Parts Identification Manual  
(B005-0000-1287)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Site Preparation  
v
Table of Contents  
Introduction .........................................................................1  
Interpreting the Model Number .......................................2  
Related Site Preparation Data ...........................................3  
How to Order ......................................................................4  
Customer Responsibilities  
AC Store Wiring Requirements  
LAN Communications  
5
6
6
7
8
System Configuration Diagram  
Physical Considerations  
Operating and Service Clearance Requirements............9  
Component Dimensions ..................................................10  
NCR 7455 with Integrated Customer Display  
and PCMCIA...............................................................10  
NCR 7455 with Integrated Post Customer  
Display .........................................................................11  
7453-K005 Cash Drawer ............................................11  
NCR 2189 Cash Drawer.............................................12  
NCR 2113 Cash Drawer.............................................12  
NCR 7162 Receipt Printer..........................................13  
NCR 7194 Thermal Receipt Printer..........................13  
NCR 7166 Thermal Receipt/ Impact Printer...........14  
NCR 7158 Thermal Receipt/ Impact Printer...........14  
NCR 7196 Thermal Receipt Printer..........................15  
NCR 7455 - 4x20 Remote Post Customer  
Display .........................................................................16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
vi  
Site Preparation  
NCR 5972 2x20 Remote Post Customer Display....17  
NCR 5973 International Remote Post Customer  
Display .........................................................................18  
NCR 5972 Remote Table-Top Customer Display ..19  
NCR 2336-K007 External CD-ROM Drive ..............20  
NCR 2336-K008 USB RS-232 Port Server ................20  
Component Weights.........................................................21  
Ventilation Clearance .......................................................22  
Power Requirements ........................................................23  
Cable Routing Considerations  
24  
Considerations for Enclosed Installations.....................25  
Thermal Test Points ...................................................25  
Service Access .............................................................25  
System Cables  
26  
Cable Illustrations.............................................................28  
Dual Cash Drawer, Y-cable.......................................28  
Ethernet, 10/ 100 Base-T ............................................28  
USB, 1- or 4-Meter ......................................................28  
Printer Interface Cables (RS-232) .............................29  
NCR 5972 Remote Customer Display and  
Adapter Cables ...........................................................30  
External CD-ROM Cable...........................................31  
External Parallel Cable ..............................................31  
Automatic Change Dispenser Serial Cable.............32  
Power, AC ...................................................................32  
Environmental Requirements  
33  
Barometric Pressure..........................................................33  
Temperature ......................................................................33  
Humidity............................................................................33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Site Preparation  
vii  
AC Power Line Transient Protection  
1
Data Line Transient Protection .........................................2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
viii  
Site Preparation  
Revision Record  
Issue  
Date  
Remarks  
A
April 01 First issue  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Site Preparation  
ix  
Radio Frequency Interference Statements  
Federal Communications Commission (FCC)  
Information to User  
This equipment has been tested and found to comply with the limits for a Class A  
digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference when the equipment is operated in  
a commercial environment. This equipment generates, uses, and can radiate radio  
frequency energy and, if not installed and used in accordance with the instruction  
manual, may cause harmful interference to radio communications. Operation of this  
equipment in a residential area is likely to cause interference in which case the user  
will be required to correct the interference at his own expense.  
NCR is not responsible for any radio or television interference caused by unauthorized  
modification of this equipment or the substitution or attachment of connecting cables  
and equipment other than those specified by NCR. The correction of interference  
caused by such unauthorized modification, substitution or attachment will be the  
responsibility of the user. The user is cautioned that changes or modifications not  
expressly approved by NCR may void the users authority to operate the equipment.  
Canadian Department of Communications  
This digital apparatus does not exceed the Class A limits for radio noise emissions  
from digital apparatus set out in the Radio Interference Regulations of the Canadian  
Department of Communications.  
Le présent appareil numérique német pas de bruits radioélectriques dépassant les  
limites applicables aux appareils numériques de la classe A prescrites dans le  
Règlement sur le brouillage radioélectriques édicté par le ministrère des  
Communications du Canada.  
Voluntary Control Council for Interference (VCCI)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
x
Site Preparation  
Declaration of Conformity  
NCR Corporation  
Manufacturer’s Name  
NCR Corporation  
Manufacturer’s Address  
Retail Solutions Division  
2651 Satellite Boulevard  
Duluth, GA 30096-5810  
Information Technology Equipment  
Class 7455  
Type of Equipment  
Model Number  
100-240 V, 2.0 A, 50-60 Hz  
Electrical Ratings (Input)  
NCR Corporation, 1700 South Patterson Boulevard, Dayton, OH 45459,  
USA, declares that the equipment specified above conforms to the  
referenced EU Directives and Harmonized Standards.  
EU Directive  
Harmonized Standard(s)  
89/ 336/ EEC (EMC)  
EN 55022: 1987 (CISPR 22)  
EN 50082-1, Part 1: 1992  
IEC 801-2: 1984  
IEC 801-3: 1984  
IEC 801-4: 1988  
73/ 23/ EEC (Low Voltage) EN 60 950: 1992 +A1+A2:1993 +A3:1995  
NCR Corporation  
Retail Solutions Division— Atlanta  
2651 Satellite Boulevard  
Duluth, GA 30096-5810  
European Contact:  
International IP Counsel  
206 Marylebone Road  
London, NW1 6LY, England  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Site Preparation  
Introduction  
18427  
This document provides the information necessary to prepare a site to  
NCR specifications prior to installing a terminal. The site must be  
properly prepared before the retail terminal is installed because site  
preparation deficiencies may be difficult to detect and correct after  
installation.  
The terminal consists of separate pieces that may be combined in a  
variety of configurations. Certain combinations are mutually exclusive.  
You must determine the equipment that will actually be installed  
before proceeding with the site preparation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
Site Preparation  
Interpreting the Model Number  
NCR Model 74xx 22  
80 01  
XX  
Language  
01 = International English  
Power Required  
80 = 110 -240 VAC 50/60 Hz  
Operating System  
00 = No OS  
01 = Windows  
03 = MS/DOS  
Processor  
22 = Base Unit with 12.1" LCD  
(Release 1)  
18043  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
3
Related Site Preparation Data  
AC Power and Communications Wiring  
Title  
Order Number  
NCR Ethernet Communications Wiring Guide  
BST0-2118-82  
NCR Terminal AC Power Wiring Guidelines  
BST0-2115-53  
Peripherals  
Title  
Order Number  
NCR 7158 Thermal Receipt/ Impact Printer  
B005-0000-1112  
NCR 7162 Thermal Receipt Printer Owners Guide  
NCR 7166 Thermal Receipt/ Impact Printer  
NCR 7194 Thermal Receipt Printer Owners Guide  
NCR 7196 Thermal Receipt Printer  
B005-0000-1067  
B005-0000-1002  
B005-0000-1094  
B005-0000-1170  
BD20-1372-A  
NCR 5972 2x20 Customer Display Users Guide  
NCR 5973 2x20 (Asian Character Support) Customer BD20-1372-A  
Display Users Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4
Site Preparation  
How to Order  
Information Products are available through several different channels.  
You need an order form if you are using fax, e-mail, or mail order.  
Order forms are available to NCR personnel through QuickLook. In  
QuickLook, click on Forms & Templates, then select Information  
Products Order Form.  
Web Sites  
http:/ / inforetail.AtlantaGA.NCR.COM (NCR only)  
http:/ / www.info.NCR.COM (Anyone)  
Online Order  
Connect System (NCR only)  
Phone Order  
800-543-2010 (US area)  
622-3727 (VOICEplus)  
44-181-242-5350 (International)  
Fax Order  
937-445-6245 (US area)  
44-181-242-5355 (International)  
E-Mail  
Information+Products.Publishing@DaytonOH.NCR.COM  
(US area)  
Management.Order@unitedkingdom.ncr.com (International)  
Mail Order  
NCR Corporation IPP-Dayton  
1700 S. Patterson Boulevard  
Dayton, OH 45479  
USA  
NCR Corporation  
915 High Road  
North Finchley  
London N12 ONH  
United Kingdom  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
5
Customer Responsibilities  
Before the system can be installed, the customer must do or provide  
the following:  
When required by NCR, provide the NCR Customer Services  
representative with appropriate drawings that indicate:  
Location of the equipment  
Site wiring (power and communications, paths and lengths)  
Location of other equipment that may generate electrical noise,  
electromagnetic interference, or heat.  
Make building alterations necessary to meet wiring and other site  
requirements  
Provide and install all communications cables, wall jacks, special  
connectors, and associated hardware  
Provide and install necessary power distribution boxes, conduits,  
grounds, lightning protection devices, and associated hardware  
Make sure all applicable codes, regulations, and laws (including,  
but not limited to, electrical, building, safety, and health) are met  
Provide and install auxiliary power or other equipment as required  
Provide storage or service areas as required  
Meet all system/ unit environmental requirements  
Provide and install floor coverings and environmental systems that  
limit or control static electricity build-up and discharge  
In general, keep the NCR equipment area free from dust, smoke, lint,  
and other particles. Restrict smoking, eating, and drinking around the  
equipment. Avoid locating the equipment near other machines that  
generate ink, carbon, and paper dust particles.  
Finally, only the customer can know the full extent of the damage that  
may be caused to his business by reason of failure of the equipment  
that is to be installed. For this reason, it is the customer's responsibility  
to ascertain the extent of any such possible damage to his existing or  
planned business, and to effect full insurance for all eventualities.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
Site Preparation  
AC Store Wiring Requirements  
The customer must provide suitable AC power for the retail terminals,  
associated equipment, and devices. A dedicated unswitched power  
line dedicated to the NCR equipment installation is recommended.  
Refer to the Workstation and Peripherals AC Wiring Guide (BSTO-  
2115-53) for store AC wiring requirements. The AC outlet must be  
installed near the retail terminal and easily accessible to the operator.  
LAN Communications  
The terminal supports Ethernet 10/ 100 Base local area network (LAN)  
communication protocol. For Ethernet communications wiring  
specifications, refer to the NCR Ethernet Wiring Guide (BST0-2118-82).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
7
System Configuration Diagram  
NOTE: 7837 connect  
to RS-232 or Wedge  
Serial Only  
7837  
7448  
Customer  
Display  
5972-1000  
5972-2000  
Customer  
Customer  
Display  
Display  
5973  
International  
Customer  
Display  
PS/2 or USB  
Keyboard  
CRT  
Operator or  
Customer  
Display  
Parallel/  
Serial  
VGA  
PS/2  
KBD  
LCD Wedge  
*
*
NOTE: 7158 & 7196 connect  
to RS-232 or USB  
Aux  
Power  
Aux Power  
Parallel  
RS-232 Transaction Printers  
*
USB  
7194  
7196  
7166  
7158  
7455  
7162  
2113  
Cash Drawer  
LAN  
Aux Power  
2189  
7454-K005  
Ethernet  
RS-232 Peripherals  
Cash Drawers  
AC  
Only  
AC  
Only  
AC  
5992  
Signature  
Capture  
7892  
Bi-modal  
Presentation  
Scanner  
5945  
7880  
Scanner/Scale  
Electronic  
Payment  
Terminal  
7875  
Scanner/Scale  
7872  
Scanner/Scale  
18984  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8
Site Preparation  
Physical Considerations  
This section presents the following retail terminal information:  
Operating and service clearance requirements  
Display mounting considerations  
Retail terminal and component dimensions  
Component weights  
Airflow requirements  
Power requirements  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
9
Operating and Service Clearance Requirements  
Location  
Above  
Component  
Distance  
Reason  
7158 Printer  
305 mm (12 in.)  
Clearance to raise printer cover  
Clearance to raise printer cover  
Clearance to raise printer cover  
Clearance to raise printer cover  
Clearance to raise printer cover  
Clearance for CRT tilt  
7162 Printer  
7166 Printer  
7194 Printer  
7196 Printer  
CRT Displays  
197 mm (7.75 in.)  
280 mm (11 in.)  
228 mm (9 in.)  
254 mm (10 in)  
50 mm (2 in.)  
5972-1000  
25 mm (1 in.)  
Clearance for display tilt  
2 x 20 Display  
All units  
All units  
153 mm (6 in.)  
153 mm (6 in.)  
Service clearance  
Service clearance  
Left Side  
5972 2 x 20 Display 25 mm (1 in.)  
Clearance for display rotation  
Service clearance  
Right Side  
All units  
202 mm (8 in.)  
127 mm (5 in.)  
330 mm (13 in.)  
76 mm (4 in.)  
153 mm (6 in.)  
7162 Printer  
Drawer unit  
7162 Printer  
All units  
Clearance to open printer door  
Clearance to open drawer  
Clearance to raise printer cover  
Service clearance  
Front  
Behind  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10  
Site Preparation  
Component Dimensions  
NCR 7455 with Integrated Customer Display and PCMCIA  
475 mm  
(18.7 in.)  
445 mm  
(17.5 in.)  
380 mm  
(15.0 in.)  
7
4
1
8
5
2
9
6
3
466 mm  
(18.3 in.)  
18818  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
11  
NCR 7455 with Integrated Post Customer Display  
475 mm  
(18.7 in.)  
480 mm  
(19.0 in.)  
7
4
1
8
5
2
9
6
3
406 mm  
(16.0 in.)  
18817  
7453-K005 Cash Drawer  
455.6 mm  
( 17.94in.)  
108 mm  
(4.25 in.)  
450.9 mm  
(17.75 in.)  
263.5 mm  
(10.375 in.)  
Operating and Service  
Clearance for Drawer  
18038  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
12  
Site Preparation  
NCR 2189 Cash Drawer  
464 mm  
(18.25 in.)  
133 mm  
(5.25 in.)  
527 mm  
(20.5 in.)  
330 mm  
(13 in.)  
Operating and  
Service Clearance  
for Drawer  
16676  
NCR 2113 Cash Drawer  
400 mm  
(15.75 in.)  
96 mm  
(3.75 in.)  
450 mm  
(17.75 in.)  
254 mm  
(10 in.)  
Operating and  
Service Clearance  
for Drawer  
17310  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
13  
NCR 7162 Receipt Printer  
148mm  
(5.5 in.)  
240 mm  
(9.45 in.)  
165 mm  
(6.5 in.)  
16099  
NCR 7194 Thermal Receipt Printer  
212 mm  
(8.3 in.)  
130 mm  
(5.10 in.)  
85 mm  
(3.30 in.)  
157 mm  
(6.20 in.)  
187 mm  
(7.4 in.)  
16492  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
14  
Site Preparation  
NCR 7166 Thermal Receipt/Impact Printer  
171 mm  
(6.75 in.)  
280 mm  
(11.00 in.)  
330 mm  
248 mm  
(13.00 in.)  
(9.75 in.)  
17308  
NCR 7158 Thermal Receipt/Impact Printer  
165 mm  
(6.50 in.)  
305 mm  
(12.00 in.)  
229 mm  
(9.00 in)  
336 mm  
(13.25 in)  
17307  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
15  
NCR 7196 Thermal Receipt Printer  
146 mm  
(5.75 in.)  
254 mm  
(10.00 in.)  
108 mm  
(4.25 in.)  
140 m  
(5.50 in.)  
17306  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
16  
Site Preparation  
NCR 7455 - 4x20 Remote Post Customer Display  
180 mm  
(7 in.)  
50 mm  
(3.5 in.)  
110 mm  
(4.25 in.)  
506 mm  
(22.1 in.)  
95 mm  
(3.75 in.)  
95 mm  
(3.75 in.)  
18819  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
17  
NCR 5972 2x20 Remote Post Customer Display  
30 mm  
(1.2 in.)  
262 mm  
(10.3 in.)  
119 mm  
(4.7 in.)  
506 mm  
(22.1 in.)  
95 mm  
(3.75 in.)  
95 mm  
(3.75 in.)  
15708  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
18  
Site Preparation  
NCR 5973 International Remote Post Customer Display  
262 mm  
(10.3 in.)  
45 mm  
(1.8 in.)  
110 mm  
(4.3 in.)  
350 mm  
(13.8 in.)  
95 mm  
(3.75 in.)  
95 mm  
(3.75 in.)  
17236a  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
19  
NCR 5972 Remote Table-Top Customer Display  
262 mm  
45 mm  
(10.3 in.)  
(1.8 in.)  
110 mm  
(4.3 in.)  
158 mm  
(6.2 in.)  
173 mm  
(6.8 in.)  
178 mm  
(7.0 in.)  
17237  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
20  
Site Preparation  
NCR 2336-K007 External CD-ROM Drive  
155 mm  
(6.1 in.)  
218 mm  
(8.6 in.)  
23 mm  
(0.9 in.)  
16951  
Note: Allow 75 mm (3 in.) clearance in the back of the NCR 2336-K007  
External CD-ROM Drive for connector and cable clearance.  
NCR 2336-K008 USB RS-232 Port Server  
183 mm  
(7.2 in.)  
111 mm  
26 mm  
(1.0 in.)  
(4.4 in.)  
16950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
21  
Component Weights  
The following table shows the component weights for each integrated  
component.  
Retail Terminal Components  
Weight  
kg.  
9.5  
11.4  
0.7  
4.8  
1.7  
5.6  
1.3  
1.8  
0.6  
0.3  
lbs.  
20.9  
25.15  
1.5  
2189 Cash Drawer  
7453-K005 Cash Drawer  
7455 4x20 Remote Customer Display  
7158 Receipt/ Impact Printer  
7162 Receipt Only Printer  
10.5  
3.8  
7166 Receipt/ Impact Printer  
7194 Thermal Receipt Printer  
7196 Thermal Receipt Printer  
2336-K007 External CD-ROM Drive  
2336-K008 USB RS-232 Port Server  
12.3  
2.8  
3.4  
1.3  
0.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
22  
Site Preparation  
Ventilation Clearance  
Leave the minimum clearances shown below for proper cooling  
conditions for the 7455 Class Retail Terminal.  
25 mm  
(1 in.)  
76 mm  
(3 in.)  
7
4
8
5
9
6
1
2
3
Minimum Horizontal Clearance  
Minimum Vertical Clearance  
18392  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
23  
Power Requirements  
Core module contain a three-wire, single-phase, selectable 120/ 240 volt  
AC, 95 Watt power supply. The supply powers the retail terminal,  
DynaKey, MSR, some scanner, VFD display, keyboard, USB interface,  
cash drawer, and PCMCIA cards.  
The following tables show operating specifications for the power  
supply.  
Maximum Input Power Specifications  
120 volt  
90 - 136 VAC  
50/ 60 Hz  
1.0  
240 volt  
198 - 257 VAC  
50/ 60 Hz  
0.5  
Voltage Ranges  
Frequency  
Current (A)  
Power (W)  
90  
90  
Power Factor (typical)  
0.48  
0.38  
Typical Power Requirements  
System  
Retail Terminal Condition  
Amps  
0.39  
0.59  
0.66  
Watts  
20.9  
35.3  
38.3  
KVA  
0.04  
0.07  
0.08  
120 Volt 7455 Soft OFF  
7455 Idle (Power ON)  
7455 Active with 4x20  
display ON  
240 Volt 7455 Soft OFF  
0.25  
0.38  
0.43  
18.5  
37.6  
40.6  
0.05  
0.10  
0.11  
7455 Idle (Power ON)  
7455 Active with 4x20  
display ON  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
24  
Site Preparation  
Cable Routing Considerations  
External cables can be routed out the back of the Table-Top Mount.  
The internal cable connectors on the terminal are located on the  
underside of the Core Module under the Cable Cover.  
Screws (2)  
18365  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
25  
Considerations for Enclosed Installations  
Thermal Test Points  
With the terminal installed in the enclosure, verify that the temperature  
does not exceed 45o C (115o F) in the operating environment. Test the  
temperature at the rear access panel covering the CD-ROM and hard  
drive.  
18820  
Note: For terminal servicing information refer to NCR 7455 Retail  
Terminal Hardware Installation & Service (B005-0000-1285).  
Service Access  
The enclosure must provide access to certain locations for service  
purposes.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
26  
Site Preparation  
System Cables  
Cable Type  
Cable Name  
NCR Part No.  
Corp. ID No  
Approximate  
Cable Lengths  
Cash Drawer  
Dual Drawer, Y cable  
497-0409394 1416-C372-0006 0.6 m/ 2 ft  
Communications Ethernet, 10/ 100Base-T  
497-0008623  
(Unshielded)  
USB  
USB  
497-0415949 1416-C528-0010  
1 m/ 3 ft  
497-0415950 1416-C528-0040 4 m/ 13 ft  
Displays  
Remote Customer Display 497-0418248 1416-C628-1000 4 m/ 13 ft  
(Parallel Interface)  
2x20 Customer Display  
(RS-232 Interface)  
497-0415249 1416-C629-1000 4 m/ 13 ft  
Parallel I/ F Cable  
(adapter cable)  
497-0411000 1416-C472-0006 0.6 m/ 2 ft  
Power  
U.S. – Straight  
006-1009037 1416-C325-0030 3 m/ 10 ft  
250-0023191 1416-C419-0030 3 m/ 10 ft  
U.S. – Twist-lock  
Intl. – Straight BM’ Power 006-8601010 1416-C323-0030 3 m/ 10 ft  
Intl. 006-1012224 1416-C411-0030 3 m/ 10 ft  
SEV – Straight ‘BM’ Power 230-0113955 1416-C408-0030 3 m/ 10 ft  
UK – Straight BM’ Power 006-8601012 1416-C321-0030 3 m/ 10 ft  
UK – Rectangular  
230-0113956 1416-C409-0030 3 m/ 10 ft  
Australia – Straight BM 006-8601019 1416-C322-0030 3 m/ 10 ft  
Power  
Japan – Twist-lock, Straight 008-0218043 1416-C420-0030 3 m/ 10 ft  
‘BM’ Power  
Printer Interface 7194/ 7158 Printer  
7162 Printer  
497-0408349 1416-C359-0007 0.7 m/ 2 ft.  
497-0407943 1401-C266-0040 4 m/ 13 ft  
497-0409379 1416-C266-0152 15.2 m/ 50 ft  
497-0407427 1416-C337-0010 1 m/ 3.3 ft  
497-0407429 1416-C337-0040 4 m/ 13 ft  
497-0407430 1416-C337-0152 15.2 m/ 50 ft  
497-0409379 1416-C266-0152 15.2 m/ 50 ft  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
27  
Cable Type  
Cable Name  
NCR Part No.  
Corp. ID No  
Approximate  
Cable Lengths  
Printer Extender 7162/ 7166/ 7196  
497-0411815 1416-C417-0040  
4 m/ 13 ft  
Drop Cables  
Printer/ Workstation  
(7453-K641)  
7194 Printer  
7194 Printer  
497-0411816 1416-C418-0040  
497-0405945 1416-C286-0040  
4 m/ 13 ft  
4 m/ 13 ft  
Printer Power  
Supply  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28  
Site Preparation  
Cable Illustrations  
Dual Cash Drawer, Y-cable  
Cash  
DWR. #1  
497-0409394  
Cash  
DWR. #2  
16 mm  
(0.625 in.)  
51 mm  
(2.0 in.)  
Access Hole Diameters  
15808  
Ethernet, 10/100 Base-T  
Modular  
8-Pin  
Plug  
Modular  
8-Pin  
Plug  
497-0008623  
19 mm  
(.75 in.)  
19 mm  
(.75 in.)  
Access Hole Diameters  
16298  
USB, 1- or 4-Meter  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
29  
Printer Interface Cables (RS-232)  
7162/7166/7196  
25-pin  
D-shell  
Plug  
497-0407427 - 1 m  
497-0407429 - 4 m  
497-0407430 - 15 m  
9-pin  
D-shell  
Receptacle  
Workstation  
RS-232 Port  
Printer  
38 mm  
(1.5 in.)  
63.5 mm  
(2.5 in.)  
Access Hole Diameters  
13224  
7194/7158  
9-pin  
D-shell  
Receptacle  
497-0408349 - 0.7 m  
497-0407943 - 4 m  
497-0409379 - 15 m  
9-pin  
D-shell  
Receptacle  
Workstation  
RS-232 Port  
Printer  
38 mm  
(1.5 in.)  
38 mm  
(1.5 in.)  
Access Hole Diameters  
13223  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
30  
Site Preparation  
NCR 5972 Remote Customer Display and Adapter Cables  
Parallel I/F Cable  
497-0411000 - 0.6 M  
To  
Cust. Display  
Port  
25-pin  
D-Shell  
Receptacle  
24-pin  
Microfit  
Receptacle  
497-0405676 - 4 M  
1416-C278-0040  
To  
Customer  
Display  
To Power  
Brick  
8-pin  
Microfit  
Receptacle  
Access Hole Diameters  
57.1 mm  
(2.25 in.)  
19 mm  
(0.75 in.)  
25 mm  
(1.0 in.)  
16291  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
31  
External CD-ROM Cable  
25-pin  
D-Shell  
Receptacle  
28-pin  
Sub-Miniture  
D-Plug  
497-0413011 - 0.6 M  
1416-C464-0006  
To 7455  
Cust. Display  
Port  
To CD-ROM  
Parallel  
Connector  
To CD-ROM  
Power  
Connector  
SMK  
2 mm Plug  
Access Hole Diameters  
57 mm  
(2.25 in.)  
12 mm  
(0.5 in.)  
31 mm  
(1.25 in.)  
16959  
External Parallel Cable  
25-pin  
D-Shell  
Receptacle  
28-pin  
Sub-Miniture  
D-Plug  
497-0411000-0.6 M  
1416-C472-0006  
To 7455  
Cust. Display  
Port  
To CD-ROM  
Parallel  
Connector  
Access Hole Diameters  
57 mm  
(2.25 in.)  
31 mm  
(1.25 in.)  
17390  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
32  
Site Preparation  
Automatic Change Dispenser Serial Cable  
P1  
P2  
497-0404832  
5
9
13  
25  
1
6
9-Pin  
D-shell  
Receptacle  
1
14  
25-pin  
D-shell  
Plug  
18056  
Power, AC  
006-1009037  
Workstation  
45 mm  
(1.75 in.)  
Access Hole Diameter  
15405  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Site Preparation  
33  
Environmental Requirements  
Barometric Pressure  
The 7455 Retail Terminal is designed to operate within the following  
barometric pressure conditions:  
Maximum operating altitude: 3000 m (9843 ft)  
Operating range of pressure: 105 kPa to 69 kPa (15.2 lb/ in. to 10.0  
lb/ in.)  
Temperature  
The 7455 Retail Terminal is designed to operate over the temperature  
ranges shown below. Continuous operation must be avoided, however,  
at or near the temperature extremes, or in locations where temperature  
changes exceed the temperature restrictions.  
Temperature Parameter Restriction  
Operating  
Storage  
o
o
o
o
5 C to 45 C (41 F to 113 F), dry bulb  
o
o
o
o
-10 C to 50 C (14 F to 122 F), three months  
Shipping  
Dew Point  
o
o
o
o
-40 C to 60 C (-40 F to 140 F), one week  
o
o
26 C (79 F) maximum  
Humidity  
The 7455 Retail Terminal is designed to operate within the humidity  
ranges shown below. Continuous operation must be avoided, however,  
at or near the humidity limits, or in locations where humidity changes  
exceed the humidity restrictions. In no case should the 7455 Retail  
Terminal be subjected to condensation.  
Humidity Type  
Restriction  
Relative  
10% to 90%  
Maximum change rate 10%/ 60 minutes  
Storage  
10% to 90% relative humidity, three months  
5% to 95% relative humidity, one week  
Shipping  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
34  
Site Preparation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A: Transient Protection  
AC Power Line Transient Protection  
In the process of power distribution, transient electrical energy  
(including, but not limited to, lightning strikes, intermittent short  
circuits, and switching transients) can be introduced onto power lines.  
Such transient energy can be very damaging to electronic hardware,  
and can also cause data corruption. Under these circumstances, NCR  
recommends the use of AC power transient suppressors. Such  
protection devices are intended to guard against power line transients  
that can result in hardware damage and various system or program  
errors.  
Improvement of any deficiencies in power quality is a customer  
responsibility. Malfunction and/ or component failure as a result of  
power quality problems is not covered by the NCR Maintenance  
Agreement. NCR accepts no liability for any such occurrence or for its  
consequences.  
When power transient suppression is required, the suppressors used  
should meet the following minimum requirements:  
Dissipate energy to match the appropriate application categories as  
defined by IEEE Standard 587.  
Be of the voltage limiting (clipping), or tracking filter type. The  
suppressor must not clamp the voltage to zero, and must self-  
recover after the passage of the transient. The suppressor may be of  
the hybrid type construction that makes use of various technologies  
in order to meet speed and dissipation requirements.  
Upon failure, exhibit a positive indication of its failure such as a  
blown fuse or tripped breaker.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-2 Appendix A: Transient Protection  
Be listed by the accepted safety organization for the country  
involved (UL, CSA, VDE, ETL, and so on) and the installation must  
conform to local, state, and national electrical codes and  
regulations.  
Data Line Transient Protection  
The nature of the transient phenomenon may extend to the data  
communication lines connected to this equipment. It is the  
responsibility of the customer to install and connect a data line  
transient suppression system to correct or prevent any deficiencies.  
Such systems must meet the following minimum requirements:  
Be of the voltage limiting type and must self-recover after passage  
of the transient.  
Insert less than 5 ohms resistance and minimal inductive and  
capacitive loading at the operating frequency for non-MIRLAN  
data lines, in order to avoid signal degradation.  
Be installed in accordance with all applicable local, state, and  
national electrical codes and regulations.  
Note: In certain countries, NCR is able to supply both power and data  
line transient suppressors as well as a comprehensive line of power  
conditioning equipment. For application data, contact your NCR  
Customer Services Division Representative.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
A-i  
Index  
CD-ROM Drive, 20  
Clearance Requirements, 9  
Communications, 6  
Configuration Diagram, 7  
Customer Display, 18, 19  
Customer Responsibilities, 5  
—2—  
2336-K007 External CD-ROM Drive, 20  
2336-K008 USB RS-232 Port Server, 20  
—4—  
—D—  
4x20 Remote Customer Display, 16  
Dimensions, 10  
Dimensions and Weight  
Weight, 21  
—5—  
5972-1000 Remote Customer Display, 17  
5973 International VFD Customer  
Display, 18, 19  
Dual Cash Drawer, Y-cable, 28  
—E—  
—7—  
Environmental Requirements, 33  
Barometric Pressure, 33  
Humidity, 33  
7158 Thermal Receipt/ Impact Printer, 14  
7161 Thermal Receipt Printer, 13  
7166 Thermal Receipt/ Impact Printer, 14  
7194 Thermal Receipt Printer, 13  
7196 Thermal Receipt Printer, 15  
7453-K005 Cash Drawer, 11  
Temperature, 33  
Ethernet, 10/ 100 Base-T, 28  
External CD-ROM Cable, 31  
External Parallel Cable, 31  
—H—  
A—  
Humidity, 33  
ACD Serial Cable, 32  
—M—  
—C—  
Maximum operating altitude, 33  
Model Number, 2  
Cable Illustrations, 28  
Cable Routing Considerations, 24  
Cables, 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ii  
Index  
Remote Customer Display and Adapter  
Cables, 30  
RS-232 Port Server, 20  
—N—  
NCR 2113 Cash Drawer, 12  
NCR 2189 Cash Drawer, 12  
—S—  
—O—  
Service Access, 25  
Operating range of barometric pressure,  
33  
—T—  
Temperature, 33  
Thermal Test Points, 25  
—P—  
Power requirements, 23  
Printer  
7158 Thermal Receipt/ Impact Printer,  
14  
—U—  
USB, 28  
7161 Thermal Receipt Printer, 13  
7166 Thermal Receipt/ Impact Printer,  
14  
7194 Thermal Receipt Printer, 13  
7196 Thermal Receipt Printer, 15  
Printer Interface Cables (RS-232), 29  
—V—  
Ventilation Clearance, 22  
—W—  
Weight, 21  
Wiring Requirements, 6  
—R—  
Remote Customer Display, 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B005-0000-1286  
April 2001  
Printed on recycled paper  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Clothes Dryer T 1515 User Manual
Miele Cooktop KM5600 User Manual
Milwaukee Cordless Saw 0729 20 User Manual
Mr Coffee Coffeemaker JWX9 User Manual
Musica Portable Speaker 52WRM User Manual
Nikon Universal Remote MC 36 User Manual
Nokia Cell Phone 3100b User Manual
NordicTrack Treadmill NTTL25510 User Manual
Optima Company Heat Pump 600 1700 User Manual
Optimus Portable CD Player CD 3330 User Manual