NCR 7455 Retail Terminal
Release 1.0
Site Preparation
18427
B005-0000-1286
Issue A
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
i
Preface
Audience
This book is written for hardware installer/ service personnel, system
integrators, and field engineers.
Notice: This document is NCR proprietary information and is not to
be disclosed or reproduced without consent.
Safety Warnings
This equipment is intended for use with an IT power system with a line-to-
line voltage of 240 V or less.
Fuse Replacement
Caution: For continued protection against risk of fire, replace only
with the same type and ratings of fuse.
Attention: Pour prévenir et vous protéger contre un risque de feu,
remplacer la fusible avec une autre fusible de même type, seulement.
Power Supply Cord Used as Disconnect Means
Caution: The power supply cord is used as the main disconnect
device. Ensure that the socket outlet is located/ installed near the
equipment and is easily accessible.
Attention: Le cordon d'alimentation est utilisé comme interrupteur
général. La prise de courant doit être située ou installée å proximité du
matériel et être facile d'accés.
Warning: DO NOT connect or disconnect the transaction printer
while the terminal is powered on. This can result in system or printer
damage.
Download from Www.Somanuals.com. All Manuals Search And Download.
ii
Site Preparation
Lithium Battery Warning
Caution: Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type as recommended by the
manufacturer. Discard used batteries according to the manufacturer's
instructions.
Attention: Il y a danger d'explosion s'il y a remplacement incorrect de
la batterie. Remplacer uniquement avec une batterie du même type ou
d'un type recommandé par le constructeur. Mettre au rébut les
batteries usagées conformément aux instructions du fabricant.
Peripheral Usage
This terminal should only be used with peripheral devices that are
certified by the appropriate safety agency for the country of installation
(UL, CSA, TUV, VDE) or those which are recommended by NCR
Corporation.
Environmental Consciousness
NCR is demonstrating its concern for the environment by designing an
intelligent power management system into this terminal that operates
efficiently whether the system is in a stand-alone or network
environment.
About this Book
This book provides site preparation information for terminal
components. Peripheral component and AC wiring site preparation
information is NOT provided in this book. The associated reference
documents are listed in the “Related Site Preparation Data” section.
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
iii
This book contains the information necessary for the preparation of a
site that conforms to NCR specifications. It is very important that the
site complies with the requirements specified in the document because,
once the equipment has been installed, deficiencies in site preparation
or the problems caused by these deficiencies are much more difficult to
detect and correct. Further, failure to comply with these requirements
or to take proper steps to protect equipment against risks identified in
this document may cause serious damage to the equipment and to the
customer’s business.
In addition to the need to comply with the requirements specified,
electrical wiring and mechanical systems must also comply with all
relevant codes, laws, and regulations.
It is important that a customer or his agent who is fully conversant
with the special requirements of electronic equipment prepare the site.
The responsibility of ensuring that the site is prepared in compliance
with this document remains with the customer.
For information and guidance purposes only, a list is provided, in
general terms, of those matters for which the customer is responsible.
This list is not intended to be comprehensive, and in no way modifies,
alters, or limits the responsibility of the customer for all aspects of
adequate site preparation.
NCR staff will be available to answer questions relating to the contents
of this document except where:
•
A customer has been notified that a full or partial consultant service
is available and/ or that NCR will be willing to undertake a
preliminary or final site survey and
•
The customer shall have entered into a formal contract with NCR
for provision of the same.
No comment, suggestion, or advice offered or not offered about
preparation of the site, nor any inspection of the site, whether before of
after preparation, is to be taken as approval of the location of the site
and equipment or its preparation. NCR will not be liable in respect to
any comment, suggestion, or advice given by its staff or in respect to
any failure to give advice.
Download from Www.Somanuals.com. All Manuals Search And Download.
iv
Site Preparation
Finally, only the customer can know the full extent of damage that may
be caused to his business by reason of failure of the equipment which is
to be installed. For this reason, it is the customer’s responsibility to
ascertain the extent of any possible damage to his existing or planned
business, and to effect full insurance in for all eventualities.
References
•
•
•
•
NCR 7455 Retail Terminal User’s Guide
(B005-0000-1285)
NCR 7455 Retail Terminal Service Guide
(B005-0000-1339)
NCR FitClient User's Guide
(B005-0000-1235)
NCR 7455 Retail Terminal Parts Identification Manual
(B005-0000-1287)
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
v
Table of Contents
Introduction .........................................................................1
Interpreting the Model Number .......................................2
Related Site Preparation Data ...........................................3
How to Order ......................................................................4
Customer Responsibilities
AC Store Wiring Requirements
LAN Communications
5
6
6
7
8
System Configuration Diagram
Physical Considerations
Operating and Service Clearance Requirements............9
Component Dimensions ..................................................10
NCR 7455 with Integrated Customer Display
and PCMCIA...............................................................10
NCR 7455 with Integrated Post Customer
Display .........................................................................11
7453-K005 Cash Drawer ............................................11
NCR 2189 Cash Drawer.............................................12
NCR 2113 Cash Drawer.............................................12
NCR 7162 Receipt Printer..........................................13
NCR 7194 Thermal Receipt Printer..........................13
NCR 7166 Thermal Receipt/ Impact Printer...........14
NCR 7158 Thermal Receipt/ Impact Printer...........14
NCR 7196 Thermal Receipt Printer..........................15
NCR 7455 - 4x20 Remote Post Customer
Display .........................................................................16
Download from Www.Somanuals.com. All Manuals Search And Download.
vi
Site Preparation
NCR 5972 2x20 Remote Post Customer Display....17
NCR 5973 International Remote Post Customer
Display .........................................................................18
NCR 5972 Remote Table-Top Customer Display ..19
NCR 2336-K007 External CD-ROM Drive ..............20
NCR 2336-K008 USB RS-232 Port Server ................20
Component Weights.........................................................21
Ventilation Clearance .......................................................22
Power Requirements ........................................................23
Cable Routing Considerations
24
Considerations for Enclosed Installations.....................25
Thermal Test Points ...................................................25
Service Access .............................................................25
System Cables
26
Cable Illustrations.............................................................28
Dual Cash Drawer, Y-cable.......................................28
Ethernet, 10/ 100 Base-T ............................................28
USB, 1- or 4-Meter ......................................................28
Printer Interface Cables (RS-232) .............................29
NCR 5972 Remote Customer Display and
Adapter Cables ...........................................................30
External CD-ROM Cable...........................................31
External Parallel Cable ..............................................31
Automatic Change Dispenser Serial Cable.............32
Power, AC ...................................................................32
Environmental Requirements
33
Barometric Pressure..........................................................33
Temperature ......................................................................33
Humidity............................................................................33
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
vii
AC Power Line Transient Protection
1
Data Line Transient Protection .........................................2
Download from Www.Somanuals.com. All Manuals Search And Download.
viii
Site Preparation
Revision Record
Issue
Date
Remarks
A
April 01 First issue
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
ix
Radio Frequency Interference Statements
Federal Communications Commission (FCC)
Information to User
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause interference in which case the user
will be required to correct the interference at his own expense.
NCR is not responsible for any radio or television interference caused by unauthorized
modification of this equipment or the substitution or attachment of connecting cables
and equipment other than those specified by NCR. The correction of interference
caused by such unauthorized modification, substitution or attachment will be the
responsibility of the user. The user is cautioned that changes or modifications not
expressly approved by NCR may void the user’s authority to operate the equipment.
Canadian Department of Communications
This digital apparatus does not exceed the Class A limits for radio noise emissions
from digital apparatus set out in the Radio Interference Regulations of the Canadian
Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les
limites applicables aux appareils numériques de la classe A prescrites dans le
Règlement sur le brouillage radioélectriques édicté par le ministrère des
Communications du Canada.
Voluntary Control Council for Interference (VCCI)
Download from Www.Somanuals.com. All Manuals Search And Download.
x
Site Preparation
Declaration of Conformity
NCR Corporation
Manufacturer’s Name
NCR Corporation
Manufacturer’s Address
Retail Solutions Division
2651 Satellite Boulevard
Duluth, GA 30096-5810
Information Technology Equipment
Class 7455
Type of Equipment
Model Number
100-240 V, 2.0 A, 50-60 Hz
Electrical Ratings (Input)
NCR Corporation, 1700 South Patterson Boulevard, Dayton, OH 45459,
USA, declares that the equipment specified above conforms to the
referenced EU Directives and Harmonized Standards.
EU Directive
Harmonized Standard(s)
89/ 336/ EEC (EMC)
EN 55022: 1987 (CISPR 22)
EN 50082-1, Part 1: 1992
IEC 801-2: 1984
IEC 801-3: 1984
IEC 801-4: 1988
73/ 23/ EEC (Low Voltage) EN 60 950: 1992 +A1+A2:1993 +A3:1995
NCR Corporation
Retail Solutions Division— Atlanta
2651 Satellite Boulevard
Duluth, GA 30096-5810
European Contact:
International IP Counsel
206 Marylebone Road
London, NW1 6LY, England
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
Introduction
18427
This document provides the information necessary to prepare a site to
NCR specifications prior to installing a terminal. The site must be
properly prepared before the retail terminal is installed because site
preparation deficiencies may be difficult to detect and correct after
installation.
The terminal consists of separate pieces that may be combined in a
variety of configurations. Certain combinations are mutually exclusive.
You must determine the equipment that will actually be installed
before proceeding with the site preparation.
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Site Preparation
Interpreting the Model Number
NCR Model 74xx 22
80 01
XX
Language
01 = International English
Power Required
80 = 110 -240 VAC 50/60 Hz
Operating System
00 = No OS
01 = Windows
03 = MS/DOS
Processor
22 = Base Unit with 12.1" LCD
(Release 1)
18043
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
3
Related Site Preparation Data
AC Power and Communications Wiring
Title
Order Number
NCR Ethernet Communications Wiring Guide
BST0-2118-82
NCR Terminal AC Power Wiring Guidelines
BST0-2115-53
Peripherals
Title
Order Number
NCR 7158 Thermal Receipt/ Impact Printer
B005-0000-1112
NCR 7162 Thermal Receipt Printer Owner’s Guide
NCR 7166 Thermal Receipt/ Impact Printer
NCR 7194 Thermal Receipt Printer Owner’s Guide
NCR 7196 Thermal Receipt Printer
B005-0000-1067
B005-0000-1002
B005-0000-1094
B005-0000-1170
BD20-1372-A
NCR 5972 2x20 Customer Display User’s Guide
NCR 5973 2x20 (Asian Character Support) Customer BD20-1372-A
Display User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Site Preparation
How to Order
Information Products are available through several different channels.
You need an order form if you are using fax, e-mail, or mail order.
Order forms are available to NCR personnel through QuickLook. In
QuickLook, click on Forms & Templates, then select Information
Products Order Form.
Web Sites
•
•
http:/ / inforetail.AtlantaGA.NCR.COM (NCR only)
http:/ / www.info.NCR.COM (Anyone)
Online Order
•
Connect System (NCR only)
Phone Order
•
•
•
800-543-2010 (US area)
622-3727 (VOICEplus)
44-181-242-5350 (International)
Fax Order
•
•
937-445-6245 (US area)
44-181-242-5355 (International)
E-Mail
•
Information+Products.Publishing@DaytonOH.NCR.COM
(US area)
•
Management.Order@unitedkingdom.ncr.com (International)
Mail Order
•
NCR Corporation IPP-Dayton
1700 S. Patterson Boulevard
Dayton, OH 45479
USA
•
NCR Corporation
915 High Road
North Finchley
London N12 ONH
United Kingdom
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
5
Customer Responsibilities
Before the system can be installed, the customer must do or provide
the following:
•
When required by NCR, provide the NCR Customer Services
representative with appropriate drawings that indicate:
− Location of the equipment
− Site wiring (power and communications, paths and lengths)
− Location of other equipment that may generate electrical noise,
electromagnetic interference, or heat.
•
•
•
•
Make building alterations necessary to meet wiring and other site
requirements
Provide and install all communications cables, wall jacks, special
connectors, and associated hardware
Provide and install necessary power distribution boxes, conduits,
grounds, lightning protection devices, and associated hardware
Make sure all applicable codes, regulations, and laws (including,
but not limited to, electrical, building, safety, and health) are met
•
•
•
•
Provide and install auxiliary power or other equipment as required
Provide storage or service areas as required
Meet all system/ unit environmental requirements
Provide and install floor coverings and environmental systems that
limit or control static electricity build-up and discharge
In general, keep the NCR equipment area free from dust, smoke, lint,
and other particles. Restrict smoking, eating, and drinking around the
equipment. Avoid locating the equipment near other machines that
generate ink, carbon, and paper dust particles.
Finally, only the customer can know the full extent of the damage that
may be caused to his business by reason of failure of the equipment
that is to be installed. For this reason, it is the customer's responsibility
to ascertain the extent of any such possible damage to his existing or
planned business, and to effect full insurance for all eventualities.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Site Preparation
AC Store Wiring Requirements
The customer must provide suitable AC power for the retail terminals,
associated equipment, and devices. A dedicated unswitched power
line dedicated to the NCR equipment installation is recommended.
Refer to the Workstation and Peripherals AC Wiring Guide (BSTO-
2115-53) for store AC wiring requirements. The AC outlet must be
installed near the retail terminal and easily accessible to the operator.
LAN Communications
The terminal supports Ethernet 10/ 100 Base local area network (LAN)
communication protocol. For Ethernet communications wiring
specifications, refer to the NCR Ethernet Wiring Guide (BST0-2118-82).
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
7
System Configuration Diagram
NOTE: 7837 connect
to RS-232 or Wedge
Serial Only
7837
7448
Customer
Display
5972-1000
5972-2000
Customer
Customer
Display
Display
5973
International
Customer
Display
PS/2 or USB
Keyboard
CRT
Operator or
Customer
Display
Parallel/
Serial
VGA
PS/2
KBD
LCD Wedge
*
*
NOTE: 7158 & 7196 connect
to RS-232 or USB
Aux
Power
Aux Power
Parallel
RS-232 Transaction Printers
*
USB
7194
7196
7166
7158
7455
7162
2113
Cash Drawer
LAN
Aux Power
2189
7454-K005
Ethernet
RS-232 Peripherals
Cash Drawers
AC
Only
AC
Only
AC
5992
Signature
Capture
7892
Bi-modal
Presentation
Scanner
5945
7880
Scanner/Scale
Electronic
Payment
Terminal
7875
Scanner/Scale
7872
Scanner/Scale
18984
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Site Preparation
Physical Considerations
This section presents the following retail terminal information:
•
•
•
•
•
•
Operating and service clearance requirements
Display mounting considerations
Retail terminal and component dimensions
Component weights
Airflow requirements
Power requirements
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
9
Operating and Service Clearance Requirements
Location
Above
Component
Distance
Reason
7158 Printer
305 mm (12 in.)
Clearance to raise printer cover
Clearance to raise printer cover
Clearance to raise printer cover
Clearance to raise printer cover
Clearance to raise printer cover
Clearance for CRT tilt
7162 Printer
7166 Printer
7194 Printer
7196 Printer
CRT Displays
197 mm (7.75 in.)
280 mm (11 in.)
228 mm (9 in.)
254 mm (10 in)
50 mm (2 in.)
5972-1000
25 mm (1 in.)
Clearance for display tilt
2 x 20 Display
All units
All units
153 mm (6 in.)
153 mm (6 in.)
Service clearance
Service clearance
Left Side
5972 2 x 20 Display 25 mm (1 in.)
Clearance for display rotation
Service clearance
Right Side
All units
202 mm (8 in.)
127 mm (5 in.)
330 mm (13 in.)
76 mm (4 in.)
153 mm (6 in.)
7162 Printer
Drawer unit
7162 Printer
All units
Clearance to open printer door
Clearance to open drawer
Clearance to raise printer cover
Service clearance
Front
Behind
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Site Preparation
Component Dimensions
NCR 7455 with Integrated Customer Display and PCMCIA
475 mm
(18.7 in.)
445 mm
(17.5 in.)
380 mm
(15.0 in.)
7
4
1
8
5
2
9
6
3
466 mm
(18.3 in.)
18818
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
11
NCR 7455 with Integrated Post Customer Display
475 mm
(18.7 in.)
480 mm
(19.0 in.)
7
4
1
8
5
2
9
6
3
406 mm
(16.0 in.)
18817
7453-K005 Cash Drawer
455.6 mm
( 17.94in.)
108 mm
(4.25 in.)
450.9 mm
(17.75 in.)
263.5 mm
(10.375 in.)
Operating and Service
Clearance for Drawer
18038
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Site Preparation
NCR 2189 Cash Drawer
464 mm
(18.25 in.)
133 mm
(5.25 in.)
527 mm
(20.5 in.)
330 mm
(13 in.)
Operating and
Service Clearance
for Drawer
16676
NCR 2113 Cash Drawer
400 mm
(15.75 in.)
96 mm
(3.75 in.)
450 mm
(17.75 in.)
254 mm
(10 in.)
Operating and
Service Clearance
for Drawer
17310
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
13
NCR 7162 Receipt Printer
148mm
(5.5 in.)
240 mm
(9.45 in.)
165 mm
(6.5 in.)
16099
NCR 7194 Thermal Receipt Printer
212 mm
(8.3 in.)
130 mm
(5.10 in.)
85 mm
(3.30 in.)
157 mm
(6.20 in.)
187 mm
(7.4 in.)
16492
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Site Preparation
NCR 7166 Thermal Receipt/Impact Printer
171 mm
(6.75 in.)
280 mm
(11.00 in.)
330 mm
248 mm
(13.00 in.)
(9.75 in.)
17308
NCR 7158 Thermal Receipt/Impact Printer
165 mm
(6.50 in.)
305 mm
(12.00 in.)
229 mm
(9.00 in)
336 mm
(13.25 in)
17307
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
15
NCR 7196 Thermal Receipt Printer
146 mm
(5.75 in.)
254 mm
(10.00 in.)
108 mm
(4.25 in.)
140 m
(5.50 in.)
17306
Download from Www.Somanuals.com. All Manuals Search And Download.
16
Site Preparation
NCR 7455 - 4x20 Remote Post Customer Display
180 mm
(7 in.)
50 mm
(3.5 in.)
110 mm
(4.25 in.)
506 mm
(22.1 in.)
95 mm
(3.75 in.)
95 mm
(3.75 in.)
18819
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
17
NCR 5972 2x20 Remote Post Customer Display
30 mm
(1.2 in.)
262 mm
(10.3 in.)
119 mm
(4.7 in.)
506 mm
(22.1 in.)
95 mm
(3.75 in.)
95 mm
(3.75 in.)
15708
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Site Preparation
NCR 5973 International Remote Post Customer Display
262 mm
(10.3 in.)
45 mm
(1.8 in.)
110 mm
(4.3 in.)
350 mm
(13.8 in.)
95 mm
(3.75 in.)
95 mm
(3.75 in.)
17236a
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
19
NCR 5972 Remote Table-Top Customer Display
262 mm
45 mm
(10.3 in.)
(1.8 in.)
110 mm
(4.3 in.)
158 mm
(6.2 in.)
173 mm
(6.8 in.)
178 mm
(7.0 in.)
17237
Download from Www.Somanuals.com. All Manuals Search And Download.
20
Site Preparation
NCR 2336-K007 External CD-ROM Drive
155 mm
(6.1 in.)
218 mm
(8.6 in.)
23 mm
(0.9 in.)
16951
Note: Allow 75 mm (3 in.) clearance in the back of the NCR 2336-K007
External CD-ROM Drive for connector and cable clearance.
NCR 2336-K008 USB RS-232 Port Server
183 mm
(7.2 in.)
111 mm
26 mm
(1.0 in.)
(4.4 in.)
16950
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
21
Component Weights
The following table shows the component weights for each integrated
component.
Retail Terminal Components
Weight
kg.
9.5
11.4
0.7
4.8
1.7
5.6
1.3
1.8
0.6
0.3
lbs.
20.9
25.15
1.5
2189 Cash Drawer
7453-K005 Cash Drawer
7455 4x20 Remote Customer Display
7158 Receipt/ Impact Printer
7162 Receipt Only Printer
10.5
3.8
7166 Receipt/ Impact Printer
7194 Thermal Receipt Printer
7196 Thermal Receipt Printer
2336-K007 External CD-ROM Drive
2336-K008 USB RS-232 Port Server
12.3
2.8
3.4
1.3
0.6
Download from Www.Somanuals.com. All Manuals Search And Download.
22
Site Preparation
Ventilation Clearance
Leave the minimum clearances shown below for proper cooling
conditions for the 7455 Class Retail Terminal.
25 mm
(1 in.)
76 mm
(3 in.)
7
4
8
5
9
6
1
2
3
Minimum Horizontal Clearance
Minimum Vertical Clearance
18392
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
23
Power Requirements
Core module contain a three-wire, single-phase, selectable 120/ 240 volt
AC, 95 Watt power supply. The supply powers the retail terminal,
DynaKey, MSR, some scanner, VFD display, keyboard, USB interface,
cash drawer, and PCMCIA cards.
The following tables show operating specifications for the power
supply.
Maximum Input Power Specifications
120 volt
90 - 136 VAC
50/ 60 Hz
1.0
240 volt
198 - 257 VAC
50/ 60 Hz
0.5
Voltage Ranges
Frequency
Current (A)
Power (W)
90
90
Power Factor (typical)
0.48
0.38
Typical Power Requirements
System
Retail Terminal Condition
Amps
0.39
0.59
0.66
Watts
20.9
35.3
38.3
KVA
0.04
0.07
0.08
120 Volt 7455 Soft OFF
7455 Idle (Power ON)
7455 Active with 4x20
display ON
240 Volt 7455 Soft OFF
0.25
0.38
0.43
18.5
37.6
40.6
0.05
0.10
0.11
7455 Idle (Power ON)
7455 Active with 4x20
display ON
Download from Www.Somanuals.com. All Manuals Search And Download.
24
Site Preparation
Cable Routing Considerations
External cables can be routed out the back of the Table-Top Mount.
The internal cable connectors on the terminal are located on the
underside of the Core Module under the Cable Cover.
Screws (2)
18365
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
25
Considerations for Enclosed Installations
Thermal Test Points
With the terminal installed in the enclosure, verify that the temperature
does not exceed 45o C (115o F) in the operating environment. Test the
temperature at the rear access panel covering the CD-ROM and hard
drive.
18820
Note: For terminal servicing information refer to NCR 7455 Retail
Terminal Hardware Installation & Service (B005-0000-1285).
Service Access
The enclosure must provide access to certain locations for service
purposes.
Download from Www.Somanuals.com. All Manuals Search And Download.
26
Site Preparation
System Cables
Cable Type
Cable Name
NCR Part No.
Corp. ID No
Approximate
Cable Lengths
Cash Drawer
Dual Drawer, Y cable
497-0409394 1416-C372-0006 0.6 m/ 2 ft
Communications Ethernet, 10/ 100Base-T
497-0008623
(Unshielded)
USB
USB
497-0415949 1416-C528-0010
1 m/ 3 ft
497-0415950 1416-C528-0040 4 m/ 13 ft
Displays
Remote Customer Display 497-0418248 1416-C628-1000 4 m/ 13 ft
(Parallel Interface)
2x20 Customer Display
(RS-232 Interface)
497-0415249 1416-C629-1000 4 m/ 13 ft
Parallel I/ F Cable
(adapter cable)
497-0411000 1416-C472-0006 0.6 m/ 2 ft
Power
U.S. – Straight
006-1009037 1416-C325-0030 3 m/ 10 ft
250-0023191 1416-C419-0030 3 m/ 10 ft
U.S. – Twist-lock
Intl. – Straight ‘BM’ Power 006-8601010 1416-C323-0030 3 m/ 10 ft
Intl. 006-1012224 1416-C411-0030 3 m/ 10 ft
SEV – Straight ‘BM’ Power 230-0113955 1416-C408-0030 3 m/ 10 ft
UK – Straight ‘BM’ Power 006-8601012 1416-C321-0030 3 m/ 10 ft
UK – Rectangular
230-0113956 1416-C409-0030 3 m/ 10 ft
Australia – Straight ‘BM’ 006-8601019 1416-C322-0030 3 m/ 10 ft
Power
Japan – Twist-lock, Straight 008-0218043 1416-C420-0030 3 m/ 10 ft
‘BM’ Power
Printer Interface 7194/ 7158 Printer
7162 Printer
497-0408349 1416-C359-0007 0.7 m/ 2 ft.
497-0407943 1401-C266-0040 4 m/ 13 ft
497-0409379 1416-C266-0152 15.2 m/ 50 ft
497-0407427 1416-C337-0010 1 m/ 3.3 ft
497-0407429 1416-C337-0040 4 m/ 13 ft
497-0407430 1416-C337-0152 15.2 m/ 50 ft
497-0409379 1416-C266-0152 15.2 m/ 50 ft
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
27
Cable Type
Cable Name
NCR Part No.
Corp. ID No
Approximate
Cable Lengths
Printer Extender 7162/ 7166/ 7196
497-0411815 1416-C417-0040
4 m/ 13 ft
Drop Cables
Printer/ Workstation
(7453-K641)
7194 Printer
7194 Printer
497-0411816 1416-C418-0040
497-0405945 1416-C286-0040
4 m/ 13 ft
4 m/ 13 ft
Printer Power
Supply
Download from Www.Somanuals.com. All Manuals Search And Download.
28
Site Preparation
Cable Illustrations
Dual Cash Drawer, Y-cable
Cash
DWR. #1
497-0409394
Cash
DWR. #2
16 mm
(0.625 in.)
51 mm
(2.0 in.)
Access Hole Diameters
15808
Ethernet, 10/100 Base-T
Modular
8-Pin
Plug
Modular
8-Pin
Plug
497-0008623
19 mm
(.75 in.)
19 mm
(.75 in.)
Access Hole Diameters
16298
USB, 1- or 4-Meter
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
29
Printer Interface Cables (RS-232)
7162/7166/7196
25-pin
D-shell
Plug
497-0407427 - 1 m
497-0407429 - 4 m
497-0407430 - 15 m
9-pin
D-shell
Receptacle
Workstation
RS-232 Port
Printer
38 mm
(1.5 in.)
63.5 mm
(2.5 in.)
Access Hole Diameters
13224
7194/7158
9-pin
D-shell
Receptacle
497-0408349 - 0.7 m
497-0407943 - 4 m
497-0409379 - 15 m
9-pin
D-shell
Receptacle
Workstation
RS-232 Port
Printer
38 mm
(1.5 in.)
38 mm
(1.5 in.)
Access Hole Diameters
13223
Download from Www.Somanuals.com. All Manuals Search And Download.
30
Site Preparation
NCR 5972 Remote Customer Display and Adapter Cables
Parallel I/F Cable
497-0411000 - 0.6 M
To
Cust. Display
Port
25-pin
D-Shell
Receptacle
24-pin
Microfit
Receptacle
497-0405676 - 4 M
1416-C278-0040
To
Customer
Display
To Power
Brick
8-pin
Microfit
Receptacle
Access Hole Diameters
57.1 mm
(2.25 in.)
19 mm
(0.75 in.)
25 mm
(1.0 in.)
16291
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
31
External CD-ROM Cable
25-pin
D-Shell
Receptacle
28-pin
Sub-Miniture
D-Plug
497-0413011 - 0.6 M
1416-C464-0006
To 7455
Cust. Display
Port
To CD-ROM
Parallel
Connector
To CD-ROM
Power
Connector
SMK
2 mm Plug
Access Hole Diameters
57 mm
(2.25 in.)
12 mm
(0.5 in.)
31 mm
(1.25 in.)
16959
External Parallel Cable
25-pin
D-Shell
Receptacle
28-pin
Sub-Miniture
D-Plug
497-0411000-0.6 M
1416-C472-0006
To 7455
Cust. Display
Port
To CD-ROM
Parallel
Connector
Access Hole Diameters
57 mm
(2.25 in.)
31 mm
(1.25 in.)
17390
Download from Www.Somanuals.com. All Manuals Search And Download.
32
Site Preparation
Automatic Change Dispenser Serial Cable
P1
P2
497-0404832
5
9
13
25
1
6
9-Pin
D-shell
Receptacle
1
14
25-pin
D-shell
Plug
18056
Power, AC
006-1009037
Workstation
45 mm
(1.75 in.)
Access Hole Diameter
15405
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Preparation
33
Environmental Requirements
Barometric Pressure
The 7455 Retail Terminal is designed to operate within the following
barometric pressure conditions:
•
•
Maximum operating altitude: 3000 m (9843 ft)
Operating range of pressure: 105 kPa to 69 kPa (15.2 lb/ in. to 10.0
lb/ in.)
Temperature
The 7455 Retail Terminal is designed to operate over the temperature
ranges shown below. Continuous operation must be avoided, however,
at or near the temperature extremes, or in locations where temperature
changes exceed the temperature restrictions.
Temperature Parameter Restriction
Operating
Storage
o
o
o
o
5 C to 45 C (41 F to 113 F), dry bulb
o
o
o
o
-10 C to 50 C (14 F to 122 F), three months
Shipping
Dew Point
o
o
o
o
-40 C to 60 C (-40 F to 140 F), one week
o
o
26 C (79 F) maximum
Humidity
The 7455 Retail Terminal is designed to operate within the humidity
ranges shown below. Continuous operation must be avoided, however,
at or near the humidity limits, or in locations where humidity changes
exceed the humidity restrictions. In no case should the 7455 Retail
Terminal be subjected to condensation.
Humidity Type
Restriction
Relative
10% to 90%
Maximum change rate 10%/ 60 minutes
Storage
10% to 90% relative humidity, three months
5% to 95% relative humidity, one week
Shipping
Download from Www.Somanuals.com. All Manuals Search And Download.
34
Site Preparation
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Transient Protection
AC Power Line Transient Protection
In the process of power distribution, transient electrical energy
(including, but not limited to, lightning strikes, intermittent short
circuits, and switching transients) can be introduced onto power lines.
Such transient energy can be very damaging to electronic hardware,
and can also cause data corruption. Under these circumstances, NCR
recommends the use of AC power transient suppressors. Such
protection devices are intended to guard against power line transients
that can result in hardware damage and various system or program
errors.
Improvement of any deficiencies in power quality is a customer
responsibility. Malfunction and/ or component failure as a result of
power quality problems is not covered by the NCR Maintenance
Agreement. NCR accepts no liability for any such occurrence or for its
consequences.
When power transient suppression is required, the suppressors used
should meet the following minimum requirements:
•
Dissipate energy to match the appropriate application categories as
defined by IEEE Standard 587.
•
Be of the voltage limiting (clipping), or tracking filter type. The
suppressor must not clamp the voltage to zero, and must self-
recover after the passage of the transient. The suppressor may be of
the hybrid type construction that makes use of various technologies
in order to meet speed and dissipation requirements.
•
Upon failure, exhibit a positive indication of its failure such as a
blown fuse or tripped breaker.
Download from Www.Somanuals.com. All Manuals Search And Download.
A-2 Appendix A: Transient Protection
•
Be listed by the accepted safety organization for the country
involved (UL, CSA, VDE, ETL, and so on) and the installation must
conform to local, state, and national electrical codes and
regulations.
Data Line Transient Protection
The nature of the transient phenomenon may extend to the data
communication lines connected to this equipment. It is the
responsibility of the customer to install and connect a data line
transient suppression system to correct or prevent any deficiencies.
Such systems must meet the following minimum requirements:
•
Be of the voltage limiting type and must self-recover after passage
of the transient.
•
Insert less than 5 ohms resistance and minimal inductive and
capacitive loading at the operating frequency for non-MIRLAN
data lines, in order to avoid signal degradation.
•
Be installed in accordance with all applicable local, state, and
national electrical codes and regulations.
Note: In certain countries, NCR is able to supply both power and data
line transient suppressors as well as a comprehensive line of power
conditioning equipment. For application data, contact your NCR
Customer Services Division Representative.
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
A-i
Index
CD-ROM Drive, 20
Clearance Requirements, 9
Communications, 6
Configuration Diagram, 7
Customer Display, 18, 19
Customer Responsibilities, 5
—2—
2336-K007 External CD-ROM Drive, 20
2336-K008 USB RS-232 Port Server, 20
—4—
—D—
4x20 Remote Customer Display, 16
Dimensions, 10
Dimensions and Weight
Weight, 21
—5—
5972-1000 Remote Customer Display, 17
5973 International VFD Customer
Display, 18, 19
Dual Cash Drawer, Y-cable, 28
—E—
—7—
Environmental Requirements, 33
Barometric Pressure, 33
Humidity, 33
7158 Thermal Receipt/ Impact Printer, 14
7161 Thermal Receipt Printer, 13
7166 Thermal Receipt/ Impact Printer, 14
7194 Thermal Receipt Printer, 13
7196 Thermal Receipt Printer, 15
7453-K005 Cash Drawer, 11
Temperature, 33
Ethernet, 10/ 100 Base-T, 28
External CD-ROM Cable, 31
External Parallel Cable, 31
—H—
—A—
Humidity, 33
ACD Serial Cable, 32
—M—
—C—
Maximum operating altitude, 33
Model Number, 2
Cable Illustrations, 28
Cable Routing Considerations, 24
Cables, 26
Download from Www.Somanuals.com. All Manuals Search And Download.
ii
Index
Remote Customer Display and Adapter
Cables, 30
RS-232 Port Server, 20
—N—
NCR 2113 Cash Drawer, 12
NCR 2189 Cash Drawer, 12
—S—
—O—
Service Access, 25
Operating range of barometric pressure,
33
—T—
Temperature, 33
Thermal Test Points, 25
—P—
Power requirements, 23
Printer
7158 Thermal Receipt/ Impact Printer,
14
—U—
USB, 28
7161 Thermal Receipt Printer, 13
7166 Thermal Receipt/ Impact Printer,
14
7194 Thermal Receipt Printer, 13
7196 Thermal Receipt Printer, 15
Printer Interface Cables (RS-232), 29
—V—
Ventilation Clearance, 22
—W—
Weight, 21
Wiring Requirements, 6
—R—
Remote Customer Display, 17
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
B005-0000-1286
April 2001
Printed on recycled paper
Download from Www.Somanuals.com. All Manuals Search And Download.
|