Multiquip Water Pump QP2E User Manual

OPERATION AND PARTS MANUAL  
MODEL QP2E  
CENTRIFUGAL PUMP  
(ROBIN EX130D51111 GASOLINE ENGINE)  
Revision #0 (02/12/09)  
To find the latest revision of this  
publication, visit our website at:  
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
Robin EX130D5111 Engine  
QP2E Centrifugal Pump  
Proposition 65 Warning ........................................... 2  
Table Of Contents.................................................... 4  
Parts Ordering Procedures...................................... 5  
Safety Information ................................................ 6-9  
Specifications/Dimensions (Pump)........................ 10  
Specifications (Engine).......................................... 11  
General Information............................................... 12  
Pump Components................................................ 13  
Basic Engine.......................................................... 14  
Inspection .............................................................. 15  
Setup ..................................................................... 16  
Operation.......................................................... 16-17  
Maintenance..................................................... 18-22  
Troubleshooting ................................................ 24-25  
Explanation Of Code In Remarks Column............. 26  
Suggested Spare Parts ......................................... 27  
Crankcase Assy................................................ 30-31  
Crankshaft, Piston Assy....................................... 32-33  
Governor Assy.................................................... 34-35  
Camshaft Assy. .................................................. 36-37  
Air Cleaner Assy................................................. 38-39  
Cooling, Starting Assy. ........................................ 40-41  
Fuel Tank Assy.................................................... 42-43  
Carburetor Assy.................................................. 44-45  
Flywheel Assy..................................................... 46-47  
Muffler Assy........................................................ 48-49  
Cylinder Head Assy............................................. 50-51  
Accessories Assy................................................ 52-53  
Terms And Conditions Of Sale — Parts ................ 54  
Component Drawing  
Pump Assy........................................................ 28-29  
PAGE 4 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS ORDERING PROCEDURES  
Ordering parts has never been easier!  
Choose from three easy options:  
Effective:  
January 1st, 2006  
Best Deal!  
Order via Internet (Dealers Only):  
Order parts on-line using Multiquip’s SmartEquip website!  
If you have an MQ Account, to obtain a Username  
and Password, E-mail us at: parts@multiquip.  
com.  
N View Parts Diagrams  
N Order Parts  
N Print Specification Information  
To obtain an MQ Account, contact your  
District Sales Manager for more information.  
Use the internet and qualify for a 5% Discount  
on Standard orders for all orders which include  
complete part numbers.*  
to log in and save!  
Order Parts  
Note: Discounts Are Subject To Change  
Fax your order in and qualify for a 2% Discount  
on Standard orders for all orders which include  
complete part numbers.*  
Order via Fax (Dealers Only):  
All customers are welcome to order parts via Fax.  
Domestic (US) Customers dial:  
1-800-6-PARTS-7 (800-672-7877)  
Note: Discounts Are Subject To Change  
Domestic (US) Dealers Call:  
Order via Phone:  
1-800-427-1244  
Non-Dealer Customers:  
International Customers should contact  
their local Multiquip Representatives for  
Parts Ordering information.  
Contact your local Multiquip Dealer for  
parts or call 800-427-1244 for help in  
locating a dealer near you.  
When ordering parts, please supply:  
R
Dealer Account Number  
R
Specify Preferred Method of Shipment:  
R
R
R
R
R
Dealer Name and Address  
UPS/Fed Ex  
DHL  
Truck  
N
N
Priority One  
Ground  
Shipping Address (if different than billing address)  
Return Fax Number  
N Next Day  
Second/Third Day  
Applicable Model Number  
N
Quantity, Part Number and Description of Each Part  
NOTICE  
All orders are treated as Standard Orders and will  
ship the same day if received prior to 3PM PST.  
WE ACCEPT ALL MAJOR CREDIT CARDS!  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INFORMATION  
FOR YOUR SAFETY AND SAFETY OF OTHERS!  
HAZARD SYMBOLS  
Safety precautions should be followed at all  
times when operating this equipment. Failure  
to read and understand the safety messages  
and operating instructions could result in injury  
to yourself and others.  
Potential hazards associated with the operation of this  
equipment will be referenced with hazard symbols which  
may appear throughout this manual in conjunction with  
safety messages.  
This manual has been developed to  
provide complete instructions for the  
safe and efficient operation of this  
equipment. Refer to the engine  
manufacturer’s instructions for data  
relative to its safe operation.  
Before using this equipment ensure that the operating  
individual has read and understood all instructions in this  
manual.  
SAFETY MESSAGES  
The three safety messages shown below will inform you  
about potential hazards that could injure you or others.  
The safety messages specifically address the level of  
exposure to the operator, and are preceded by one of three  
words: DANGER, WARNING or CAUTION.  
DANGER  
You WILL be KILLED or SERIOUSLY INJURED if you  
DO NOT follow these directions.  
WARNING  
You CAN be KILLED or SERIOUSLY INJURED if you  
DO NOT follow these directions.  
CAUTION  
You CAN be INJURED if you DO NOT follow these  
directions.  
PAGE 6 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INFORMATION  
NEVER touch the hot exhaust manifold,  
muffler or cylinder.Allow these parts to cool  
before servicing engine or pump. Never  
operate the engine with heat shields or  
guards removed.  
GENERAL SAFETY  
DO NOT operate or service this equipment  
before reading the entire manual. The  
equipment is to be operated by trained and  
qualified personnel only! The equipment is  
for industrial use only.  
ALWAYS allow the engine to cool before adding fuel or  
performing service and maintenance functions. Contact  
with hot components can cause serious burns.  
This equipment should not be operated by persons under  
18 years of age.  
NEVER operate this equipment in any enclosed or narrow  
area where free flow of the air is restricted. The engine  
of this equipment requires an adequate free flow of  
cooling air.If the air flow is restricted it will cause serious  
damage to the equipment or  
NEVER operate this equipment without proper protective  
clothing, shatterproof glasses, respiratory protection,  
hearing protection, steel-toed boots and other protective  
devices required by the job.  
engine and may cause injury  
to people and property. The  
engine fuel exhaust gases  
contain poisonous carbon  
monoxide. This gas is  
colorless and odorless, and  
can cause death if inhaled.  
NEVER operate this equipment when not  
feeling well due to fatigue, illness or when  
under medication.  
NEVER operate this equipment under the influence of  
drugs or alcohol.  
ALWAYS refuel in a well-ventilated area, away from  
sparks and open flames. DO NOT fill the fuel tank while  
the engine is running or hot. DO NOT overfill tank, since  
spilled fuel could ignite if it comes into contact with hot  
engine parts or sparks from the ignition system. Store  
fuel in approved containers.  
NEVER disconnect any “emergency or safety  
devices.These devices are intended for operator safety.  
Disconnection of these devices can cause severe injury,  
bodily harm or even death! Disconnection of any of these  
devices will void all warranties.  
ALWAYS use extreme caution when working with  
flammable liquids.When refueling, stop the engine and  
allow it to cool.  
DO NOT smoke around or near the  
equipment. Fire or explosion could result  
from fuel vapors, or if fuel is spilled on a  
hot engine.  
NEVER use accessories or attachments that are not  
recommended by Multiquip for this equipment. Damage  
to the equipment and/or injury to user may result.  
NEVER operate the equipment in an  
explosive atmosphere or near combustible  
materials. An explosion or fire could result  
causing severe bodily harm or even death.  
Manufacturer does not assume responsibility for any  
accident due to equipment modifications. Unauthorized  
equipment modification will void all warranties.  
Whenever necessary, replace nameplate, operation and  
safety decals when they become difficult read.  
ALWAYS store equipment properly when it is not being  
used.Equipment should be stored in a clean, dry location  
out of the reach of children.  
ALWAYS check the equipment for loosened threads or  
bolts before starting.  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INFORMATION  
NEVER run engine without air cleaner. Severe engine  
LOADING AND UNLOADING  
damage may occur.  
Before lifting, make sure that equipment parts (hook and  
vibration insulator) are not damaged and screws are not  
loosened or lost.  
ALWAYS ensure pump is on level ground before use.  
NEVER pump volatile, explosive,  
flammable or low flash point fluids.  
These fluids could ignite or explode.  
NEVER pump corrosive chemicals or  
water containing toxic substances.  
These fluids could create serious health  
and environmental hazards. Contact  
local authorities for assistance.  
ALWAYS make sure crane or lifting device has been  
properly secured to the lifting bail (hook) of the  
equipment.  
NEVER lift the equipment while the engine is running.  
Use adequate lifting cable (wire or rope) of sufficient  
strength.  
NEVER open the priming plug when pump is hot. Hot  
water inside could be pressurized much like the radiator  
of an automobile.Allow pump to cool to the touch before  
loosening plug.The possibility exists of scalding, resulting  
in severe bodily harm.  
Use one point suspension hook and lift straight upwards.  
NEVER allow any person or animal to stand underneath  
the equipment while lifting.  
DO NOT lift machine to unnecessary heights.  
NEVER block or restrict flow from discharge hose.  
Remove kinks from discharge line before starting pump.  
Operation with a blocked discharge line can cause water  
inside pump to overheat.  
ALWAYS fill the pump casing with water before starting  
the engine. Failure to maintain water inside the pump  
housing will cause severe damage to the pump and  
mechanical seal.  
In winter drain water from pump housing to prevent  
freezing.  
NEVER tamper with the factory setting of  
the engine governor. Personal injury and  
equipment damage can result if operating  
in speed ranges above the maximum  
allowable.  
TRANSPORTING  
ALWAYS shutdown engine before transporting.  
Tighten fuel tank cap securely and close fuel cock to  
prevent fuel from spilling.  
ALWAYS tie down the equipment during transport by  
securing the equipment with rope.  
PAGE 8 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INFORMATION  
REFUELING  
EMERGENCIES  
ALWAYS know the location of the nearest  
fire extinguisher.  
ALWAYS know the location of the nearest  
first aid kit.  
In emergencies, always know the location  
of the nearest phone or keep a phone on the job site.  
Also know the phone numbers of the nearest  
ambulance, doctor and fire department. This  
information will be invaluable in case of emergency.  
MAINTENANCE SAFETY  
NEVER lubricate components or attempt service on a  
running machine.  
ALWAYS allow the machine a proper amount of time to  
cool before servicing.  
Keep the equipment in proper running condition.  
Fix damage to the equipment immediately and always  
replace broken parts.  
Dispose of hazardous waste properly. Examples of  
potentially hazardous waste are used motor oil, fuel and  
fuel filters.  
DO NOT use food or plastic containers to dispose of  
hazardous waste.  
DO NOT pour waste, oil or fuel directly onto the ground,  
down a drain or into any water source.  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS/DIMENSIONS (PUMP)  
Table 1. Specifications (Pump)  
QP2E  
Model  
Type  
Centrifugal Pump  
Suction and Discharge Size  
2.00 in (51 mm)  
158 gallons/minute  
(600 liters/minute)  
Maximum Pumping Capacity  
Max. Lift  
25 ft (7.62 meters)  
115 ft. (35.0 meters)  
53 lbs (24 kg)  
Max. Head  
Dry Net Weight  
Figure 1. QP2E Dimensions  
PAGE 10 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS (ENGINE)  
Table 2. Specifications (Engine)  
Model  
Robin EX130D51111  
Air cooled, 4-cycle single cylinder,  
overhead camshaft, gasoline engine  
Type  
Displacement  
Continuous Output  
7.7 cu. in (126 ml)  
3/3600 kW/rpm  
(2.2/3600 HP/rpm)  
4.3/4000 kW/rpm  
(3.2/3600 HP/rpm)  
Maximum Output  
Oil Capacity  
Fuel  
0.63 quart (0.6 liter)  
Unleaded Automobile Gasoline  
2.8 quarts (2.7 liters)  
Recoil Starter  
Fuel Tank Capacity  
Starting System  
Weight  
30.9 lbs (14 kg)  
11.7 x 13.4 x 12.5 in  
(297 x 341 x 318 mm)  
Dimensions (L x W x H)  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL INFORMATION  
DESCRIPTION  
ELEVATION  
The QP2E Centrifugal Pump is designed to handle all  
types of clear water applications. It is ideal for residential  
use such as dewatering basements and swimming pools.  
Both the suction and discharge ports on the pump use a  
2-inch diameter opening, which allows the pump to pump  
at a rate of approximately 158 gallons/minute (gpm) or 600  
liters/minute (lpm).  
Higher elevations will effect the performance of the pump.  
Due to less atmospheric pressure at higher altitudes,  
pumps do not have the priming ability that they have at  
sea level. This is due to the “thinner air” or lack of oxygen  
at higher altitudes.  
A general rule of thumb is that for every 1,000 feet of  
elevation above sea level a pump will lose one foot of  
priming ability.  
Centrifugal or self-priming pumps are designed to purge  
air from the suction line and create a partial vacuum in the  
pump body.The reduced atmospheric pressure inside the  
pump allows water to flow through the suction line and  
into the pump body. The centrifugal force created by the  
rotating impeller pressurizes the water and expels it from  
the pump.  
For example, in Flagstaff, Arizona where the elevation is  
approximately 7,000 feet, the pump would have a suction  
lift of only 18 feet rather than the 25 feet at sea level.Table 3  
shows suction lift at various elevations.  
Table 3. Suction Lift at Various Elevations  
Altitude  
ENGINE  
Suction Lift in Feet (Meters)  
Ft (Meters)  
This centrifugal pump is powered by an air-cooled 4-cycle,  
single cylinder Robin EX130D51111 gasoline engine.  
10.0  
(3.048)  
15.0  
(4.572)  
20.0  
(6.096)  
25.0  
(7.620)  
Sea Level  
8.80  
(2.680)  
13.2  
(4.023)  
17.6  
(5.364)  
22.0  
(6.705)  
STANDARD CENTRIFUGAL PUMP  
2,000 (610)  
4,000 (1,219)  
6,000 (1,829)  
8,000 (2,438)  
10,000 (3,048)  
Standard centrifugal pumps provide an economical choice  
for general purpose dewatering. These types of pumps  
should only be used in clear water applications (agricultural,  
industrial, residential) as they have a limited solid handling  
capability of only 10% by volume.  
7.80  
(2.377)  
11.7  
(3.566)  
15.6  
(4.754)  
19.5  
(5.943)  
6.90  
(2.103)  
10.4  
(3.169)  
13.8  
(4.206)  
17.3  
(5.273)  
6.20  
(1.889)  
9.30  
(2.834)  
12.4  
(3.779)  
15.5  
(4.724)  
SUCTION LIFT  
5.70  
(1.737)  
8.60  
(2.621)  
11.4  
(3.474)  
14.3  
(4.358)  
This pump is capable of suction lifts up to 25 feet at sea  
level. For optimal suction lift performance keep the suction  
hose or line as short as possible. In general, always place  
the pump as close to the water as possible.  
Table 4 shows percentage drops in performance as  
elevation increases.  
PUMP SUPPORT  
Table 4. Performance Loss at Various Elevations  
Altitude  
The pump should always be placed on solid stationary  
ground, on a level position.  
Discharge Flow Discharge Head  
Ft (Meters)  
Sea Level  
100%  
97%  
95%  
93%  
91%  
88%  
100%  
95%  
91%  
87%  
83%  
78%  
NEVER place the pump on soft soil. The suction hose or  
pipe connection should always be checked for tightness  
and leaks. A small suction leak in the hose or fittings could  
prevent the pump from priming.  
2,000 (610)  
4,000 (1,219)  
6,000 (1,829)  
8,000 (2,438)  
10,000 (3,048)  
PAGE 12 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PUMP COMPONENTS  
Figure 2 shows a typical application using the QP2E  
centrifugal pump. Please note that this pump is intended  
for the removal of clean water.  
Figure 2. QP2E Pump Application  
5. Discharge Hose — Connect this flexible rubber  
hose to the discharge port on the pump. Make sure  
that the hose lays flat and is not kinked. Use only  
recommended type discharge hose.Contact Multiquip  
parts department for ordering information.  
1. Pump — A 2-inch centrifugal pump used in general de-  
watering applications.Typical dewatering applications  
consist of dewatering basements and swimming  
pools.  
2. Fill Cap — Prior to operation, the pump casing should  
be filled with water. Remove this cap to add water to  
the pump. After the initial prime, a sufficient amount of  
water will be retained in the casing so that the operator  
will not need to re-prime later.  
6. Suction Port — Connect a 2-inch inlet hose to this  
port. Use two worm clamps to secure the hose.  
7. Suction Hose — Connect this flexible rubber hose to  
the suction port on the pump. Make sure that the hose  
lays flat and is not kinked.Use only recommended type  
suction hose. Contact Multiquip Parts Department for  
ordering information.  
If the casing is dry or has insufficient water, the pump  
will have difficulty in priming which could lead to  
premature mechanical seal wear thus causing damage  
to the pump.  
8. Drain Plug — Remove this plug to drain water from  
the pump.  
3. Discharge Port — Connect a 2-inch discharge hose  
to this port.  
9. Strainer — Always attach a strainer to bottom side of  
the suction hose to prevent large objects and debris  
from entering the pump. Strainer should be positioned  
so that it will remain completely under water. Running  
the pump with the strainer above water for long periods  
can damage pump.  
4. Worm Clamp — Used to secure the hose to the inlet  
and outlet ports on the pump.Use two clamps to secure  
the hose on the inlet side of the pump.  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BASIC ENGINE  
1
10  
9
2
8
7
3
6
5
4
Figure 3. Robin Engine Components  
6. Choke Lever — Used in the starting of a cold engine,  
or in cold weather conditions. The choke enriches the  
fuel mixture.  
The engine (Figure 3) must be checked for proper  
lubrication and filled with fuel prior to operation. Refer  
to the manufacturer's engine manual for instructions and  
details of operation and servicing.  
7. Air Cleaner — Prevents dirt and other debris from  
entering the fuel system. Remove wing-nut on top of  
air filter canister to gain access to filter element.  
1. Fuel Filler Cap — Remove this cap to add unleaded  
gasoline to the fuel tank. Make sure cap is tightened  
securely. DO NOT over fill.  
NOTICE  
Operating the engine without an air filter, with a  
damaged air filter, or a filter in need of replacement  
will allow dirt to enter the engine, causing rapid engine  
wear.  
DANGER  
Adding fuel to the tank should be done  
only when the engine is stopped and has  
had an opportunity to cool down. In the  
event of a fuel spill, DO NOT attempt to  
start the engine until the fuel residue has  
been completely wiped up and the area surrounding  
the engine is dry.  
8. Spark Plug — Provides spark to the ignition system.  
Set spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch).  
Clean spark plug once a week.  
9. Muffler — Used to reduce noise and emissions.  
WARNING  
2. Throttle Lever — Used to adjust engine RPM speed  
(lever advanced forward - SLOW, lever back toward  
operator - FAST).  
Engine components can generate extreme  
heat. To prevent burns, DO NOT touch  
these areas while the engine is running  
or immediately after operating. NEVER  
operate the engine with the muffler  
removed.  
3. Engine ON/OFF Switch ON position permits engine  
starting, OFF position stops engine operations.  
4. Recoil Starter (pull rope) — Manual-starting method.  
Pull the starter grip until resistance is felt, then pull  
briskly and smoothly.  
10. FuelTank — Holds unleaded gasoline. For additional  
information refer to engine owner's manual.  
5. Fuel Valve Lever OPEN to let fuel flow, CLOSE to  
stop the flow of fuel.  
PAGE 14 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSPECTION  
BEFORE STARTING  
Table 5. Oil Type  
1. Read safety instructions at the beginning of manual.  
Season  
Summer  
Spring/Fall  
Winter  
Temperature  
25° C or higher  
25° C - 10° C  
0° C  
Oil Type  
2. Clean the pump, removing dirt and dust, particularly the  
engine cooling air inlet, carburetor and air cleaner.  
SAE 10W-30  
SAE 10W-30/20  
SAE 10W-10  
3. Check the air filter for dirt and dust. If air filter is dirty,  
replace air filter with a new one as required.  
4. Check carburetor for external dirt and dust. Clean with  
dry compressed air.  
5. Check fastening nuts and bolts for tightness.  
DANGER  
ENGINE OIL CHECK  
Adding fuel to the tank should be done  
only when the engine is stopped and has  
had an opportunity to cool down. In the  
event of a fuel spill, DO NOT attempt to  
start the engine until the fuel residue has  
1. To check the engine oil level, place the pump on secure  
level ground with the engine stopped.  
2. Remove the filler dipstick from the engine oil filler hole  
(Figure 4) and wipe clean.  
been completely wiped up and the area surrounding  
the engine is dry.  
FUEL CHECK  
1. Remove the gasoline cap located on top of fuel tank.  
2. Visually inspect to see if the fuel level is low. If fuel is  
low, replenish with unleaded fuel.  
3. When refueling, be sure to use a strainer for filtration.  
DO NOT top-off fuel. Wipe up any spilled fuel  
immediately!  
Figure 4. Engine Oil Dipstick (Removal)  
3. Insert and remove the dipstick without screwing it  
into the filler neck. Check the oil level shown on the  
dipstick.  
4. If the oil level is low (Figure 5), fill to the edge of the oil  
filler hole with the recommended oil type (Table 4).  
Maximum oil capacity is 0.63 quarts (0.60 liters).  
Figure 5. Engine Oil Dipstick (Oil Level)  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
SETUP  
CAUTION  
1. Place pump as near to water as possible, on a firm  
flat, level surface.  
DO NOT attempt to start the engine unless the pump  
has previously been primed with water. Severe pump  
damage will occur if pump has not been primed.  
2. To prime pump, remove fill cap (Figure 2) and fill pump  
casing with water. If the pump casing is not filled with  
water before starting, it will not begin pumping.  
INITIAL STARTUP  
3. Attach suction and discharge hoses to the pump.  
Check that all hoses are securely attached to the pump.  
Make certain suction hose (Figure 2) does not have  
any air leakage. Tighten hose clamps and couplings  
as required.  
9. Place the fuel valve lever (Figure 6) in the "ON" position.  
FUEL  
4. It is recommended that 2 clamps be used when  
securing the suction hose to the inlet side (suction)  
of the pump.  
LEVER  
5. Remember suction hoses must be rigid enough not to  
collapse when the pump is in operation.  
6. Check that the discharge hose (Figure 2) is not  
restricted. Place hose so that it lays as straight as it is  
possible on the ground. Remove any twists or sharp  
bends from hose which may block the flow of water.  
Figure 6. Fuel Valve Lever  
10. Place the Engine ON/OFF switch (Figure 7) in the "ON"  
position.  
ENGINE  
ON/OFF  
NOTICE  
OFF  
SWITCH  
Suction and discharge hoses are available from  
Multiquip. Contact your nearest dealer for more  
information.,  
ON  
7. The discharge hose is usually a collapsible (thin-  
walled) hose. However if a thin-walled discharge hose  
is not available, a rigid suction hose can be substituted  
in its place.  
Figure 7. Engine ON/Off Switch  
11. Place the Choke Lever (Figure 8) in the "OPEN"  
position.  
8. Make sure the suction strainer (Figure 2) is clean  
and securely attached to the water end of the suction  
hose. The strainer is designed to protect the pump  
by preventing large objects from being pulled into the  
pump.  
CHOKE  
LEVER  
n  
OPEN  
CAUTION  
The strainer should be positioned so it will remain  
completely under water. Running the pump with the  
strainer above water for long periods can damage the  
pump.  
CLOSED  
Figure 8. Choke Lever  
PAGE 16 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
16. Check for fuel leaks and noises that would be  
associated with a loose component.Check for leaks  
between pump and engine.If water is leaking between  
the pump and engine housing, the seal inside the  
pump may be worn or damaged. Continued operation  
of the pump is not recommended.Further usage of the  
pump under these conditions may cause severe water  
damage to engine.  
NOTICE  
The CLOSED position of the choke lever enriches the  
fuel mixture for starting a COLD engine. The OPEN  
position provides the correct fuel mixture for normal  
operation after starting, and for restarting a warm  
engine.  
12. Place the throttle lever (Figure 9) halfway between fast  
and slow.  
OPERATION  
1. Once the engine has started, move the engine throttle  
lever quickly to the fast position to begin pumping. If  
water is not flowing out of the discharge port, turn off  
the engine and check for and clear any obstructions  
within the suction hose.  
THROTTLE  
LEVER  
SLOW  
FAST  
WARNING  
Water must always be flowing through the pump casing  
while the engine is running. Loss of flow may be the  
result of a loss of prime, restricted water flow or a dead-  
head situation. Please note that in such a condition,  
water in the pump can reach temperatures of 150-200°F  
in 15 to 20 minutes. This can cause serious burns if  
this hot water comes into contact with unprotected skin.  
Before touching or opening the fill plug or drain plug,  
first turn off the engine and allow the pump casing to  
cool to the touch, and then open the pump carefully.  
Be cautious of any built up water pressure.  
Figure 9. Throttle Lever  
13. Grasp the starter grip (Figure 10) and slowly pull it out.  
The resistance becomes the hardest at a certain  
position, corresponding the compression point.Rewind  
the rope a little from that point and pull out sharply.  
CAUTION  
ALWAYS run engine at full speed while pumping.  
STARTER GRIP  
Figure 10. Starter Grip  
STOPPING THE ENGINE  
CAUTION  
1. Place the throttle lever (Figure 9) in slow position, and  
listen for the engine speed to decrease.  
DO NOT pull the starter rope all the way to the end.  
DO NOT release the starter rope after pulling. Allow it  
to rewind as soon as possible.  
2. Place the Engine ON/OFF switch (Figure 7) in the  
"OFF" position.  
14. If the engine has started, slowly return the choke lever  
(Figure 8) to the CLOSED position. If the engine has  
not started repeat steps 1 through 5.  
3. Place the fuel valve lever (Figure 6) in the "OFF"  
position.  
15. Before the pump is put into operation run the engine  
for 3-5 minutes.  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
7. If the vacuum tester gauge indicates a reading below  
-20 in. Hg, it can then be assumed that the pump is  
not functioning correctly, and corrective action needs  
to be taken.  
PUMP VACUUM TEST  
CAUTION  
DO NOT attempt to start the engine unless the pump  
has previously been primed with water. Severe pump  
damage will occur if pump has not been primed.  
8. To test the flapper valve, shut down the engine. The  
vacuum tester should remain attached to the pump  
suction inlet port by vacuum.This indicates the pump's  
flapper valve is seating properly to hold water in the  
suction hose when the engine is stopped.This prevents  
backflow and allows for faster priming when the engine  
is restarted.  
To perform the pump vacuum test do the following:  
1. Remove the pump fill cap (Figure 2), and fill the pump  
with water.  
2. Start the engine as outlined in the initial start-up  
section, and wait for the pump to begin pumping.  
3. As shown in Figure 11, place a water hose inside  
the discharge opening of the pump, and turn on the  
water. This flow of water into the discharge opening  
will prevent the pump from running dry.  
4. Place the Pump Vacuum Tester (P/N 7000030) over  
the pump suction (inlet) opening (Figure 11) with the  
vacuum gauge facing upwards.It may be necessary to  
apply a small amount of water around the rubber seal  
of the vacuum tester to make a good suction fit.  
5. Check and make sure that there are no air leaks  
between the vacuum tester and the inlet port on the  
pump. If air leaks are present reset vacuum tester.  
6. Run the pump for a few minutes while monitoring the  
vacuum gauge. If the gauge indicates a reading  
between -25 and -20 in. Hg. (inches of mercury) then  
it can be assumed that the pump is working correctly.  
NOTICE  
25 in. Hg (inches of mercury) translates into 25 feet of  
lift at sea level.  
PAGE 18 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
NOTICE  
Figure 11. Pump Vacuum Tester  
Vacuum test may be performed without water flowing  
through the discharge port.However, it is recommended  
to have water flowing to prevent any heat-up.  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
ENGINE MAINTENANCE  
Perform engine maintenance procedures as listed in  
Table 6:  
Table 6. Inspection/Maintenance  
EVERY  
3
EVERY  
6
FIRST  
MONTH  
OR  
EVERY  
YEAR  
OR  
EVERY  
YEAR  
OR  
EVERY  
2YEARS  
OR  
FIRST  
25  
BEFORE  
MONTHS  
OR  
MONTHS  
OR  
DESCRIPTION (3)  
OPERATION  
HRS  
10 HRS  
100 HRS  
200 HRS  
200 HRS  
25 HRS  
50 HRS  
Check  
X
X
X
Engine Oil  
Change  
Check  
X
Air Cleaner  
Nuts and Bolts  
Spark Plug  
Change  
X (1)  
Re-Tighten If  
Necessary  
X
Check-Clean  
Replace  
Check  
X
X
X
Cooling Fins  
Spark Arrester  
Fuel Tank  
Clean  
X
X
Clean  
Fuel Filter  
Check  
X
Idle Speed  
Check-Adjust  
Check-Adjust  
Check  
X (2)  
Valve Clearance  
Fuel lines  
X
X
X (2)  
Every 2 years (replace if necessary) (2)  
(1) Service more frequently when used in DUSTY areas.  
(2) These items should be serviced by your service dealer,  
unless you have the proper tools and are mechanically proficient.  
Refer to the Robin shop Manual for service procedures.  
(3) For commercial use, log hours of operation to determine  
proper maintenance intervals.  
PAGE 20 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
Perform the engine maintenance procedures as indicated  
below:  
2. Remove the oil drain bolt and sealing washer and allow  
the oil to drain into a suitable container.  
3. Replace engine oil with recommended type oil as listed  
inTable 5.Engine oil capacity is 1.16 quarts (1.1 liters).  
DO NOT overfill.  
DAILY  
1. Thoroughly remove dirt and oil from the engine and  
control area.  
4. Install drain bolt with sealing washer and tighten  
securely.  
2. Clean or replace the air cleaner elements as  
necessary.  
ENGINE AIR CLEANER  
3. Check and retighten all fasteners as necessary.  
1. Remove the air cleaner cover and foam filter element  
as shown in Figure 14.  
4. Check the spring box and bellows for oil leaks. Repair  
or replace as needed.  
WEEKLY  
1. Remove the fuel filter cap and clean the inside of the  
fuel tank.  
2. Remove or clean the filter at the bottom of the tank.  
3. Remove and clean the spark plug (Figure 12), then  
adjust the spark gap to 0.028 ~0.031 inch (0.6~0.7  
mm). This unit has electronic ignition, which requires  
no adjustments.  
Figure 14. Engine Air Cleaner  
2. Tap the paper filter element (Figure 14) several times  
on a hard surface to remove dirt, or blow compressed  
air [not exceeding 30 psi (207 kPa, 2.1 kgf/cm2)]  
through the filter element from the air cleaner case  
side. NEVER brush off dirt. Brushing will force dirt  
into the fibers. Replace the paper filter element if it is  
excessively dirty.  
Figure 12. Spark Plug Gap  
ENGINE OIL  
1. Drain the engine oil when the oil is warm as shown in  
Figure 13.  
3. Clean foam element in warm, soapy water or  
nonflammable solvent. Rinse and dry thoroughly. Dip  
the element in clean engine oil and completely squeeze  
out the excess oil from the element before installing.  
Figure 13. Draining Engine Oil  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
PUMP STORAGE  
For storage of the pump for over 30 days, the following is  
required:  
1. Drain the fuel tank completely.  
2. Run the engine until the fuel in the carburetor is  
completely consumed.  
3. Completely drain used oil from the engine crankcase  
and fill with fresh clean oil, then follow the procedures  
described in the engine manual for engine storage.  
4. Remove the drain plug from the pump and drain out  
any water from left in the housing.  
5. Remove the pump cover and clean inside of pump  
housing. Coat inside of pump housing with a light film  
of oil to reduce corrosion. A spray can of oil works well  
for this application.  
6. Cover suction and discharge ports with duct tape to  
prevent any foreign matter from falling into pump.  
7. Cover pump and engine with plastic covering or  
equivalent and store in a clean, dry place.  
8. To protect the water-cooled seals, place one-half pint  
of lubricating oil (new or used) through the discharge  
opening on the pump and crank the engine several  
times. This will prevent excessive corrosion and also  
keep the mechanical seal lubricated.  
PAGE 22 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Table 7. Engine Troubleshooting  
Possible Cause  
Symptom  
Solution  
Spark plug bridging?  
Check gap, insulation or replace spark plug.  
Clean or replace spark plug.  
Carbon deposit on spark plug?  
Difficult to start. Fuel is  
available but no SPARK  
at spark plug.  
Short circuit due to deficient spark plug  
insulation?  
Check spark plug insulation. Replace if  
worn.  
Improper spark plug gap?  
ON/OFF switch is shorted?  
Ignition coil defective?  
Set to proper gap.  
Check switch wiring. Replace switch.  
Replace ignition coil.  
Difficult to start. Fuel is  
available and SPARK  
is present at the spark  
plug.  
Improper spark gap, points dirty?  
Set correct spark gap and clean points.  
Condenser insulation worn or short  
circuiting?  
Replace condenser.  
Spark plug wire broken or short circuiting?  
Wrong fuel type?  
Replace defective spark plug wiring.  
Difficult to start. Fuel  
is available, SPARK is  
present at the spark  
plug and compression  
is normal.  
Flush fuel system and replace with correct  
type of fuel.  
Water or dust in fuel system?  
Air cleaner dirty?  
Flush fuel system.  
Clean or replace air cleaner.  
Suction/exhaust valve stuck or protruded?  
Piston ring and/or cylinder worn?  
Reseat valves.  
Difficult to start. Fuel  
is available, SPARK is  
present at the spark  
plug and compression  
is low.  
Replace piston rings or piston.  
Cylinder head and/or spark plug not  
tightened properly?  
Torque cylinder head bolts and spark plug.  
Head gasket and/or spark plug gasket  
damaged?  
Replace head and spark plug gaskets.  
Fill with correct type of fuel.  
Fuel not available in fuel tank?  
Apply lubricant to loosen fuel cock lever.  
Replace if necessary.  
Fuel cock does not open properly?  
No fuel present at  
carburetor.  
Fuel filter clogged?  
Replace fuel filter.  
Fuel tank cap breather hole clogged?  
Air in fuel line?  
Clean or replace fuel tank cap.  
Bleed fuel line  
Air cleaner dirty?  
Clean or replace air cleaner.  
Check float adjustment. Rebuild carburetor.  
Clean or replace spark plug.  
Weak in power.  
Compression is proper Improper level in carburetor?  
and does not misfire.  
Defective spark plug?  
PAGE 24 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Table 8. Pump Troubleshooting  
Possible Cause  
Symptom  
Solution  
Not enough priming water in the housing?  
Engine speed too low?  
Add water.  
Increase throttle.  
Strainner plugged?  
Clean strainer.  
Suction hose damaged?  
Replace or repair hose, and clamps  
Check that fittings are tight and properly  
sealed.  
Air leak at suction port?  
Pump does not take on  
water.  
Pump is located too high above water line? Move pump closer to water.  
Debris collecting in pump housing?  
Clean pump housing.  
Too much distance between impeller and  
volute?-  
Adjust clearance by adding shims or replace  
impeller. Min. .006"" - Max. .020""  
Check condition of mechanical seal and  
gaskets, between pump end and engine  
housing.  
Water leaking out weep hole between pump  
and engine?  
Engine speed too low?  
Increase throttle speed.  
Clean strainer.  
Pump takes in water,  
little or no discharge.  
Suction strainer partially plugged?  
Adjust clearance by adding shims or replace  
impeller/volute  
Impeller/Volute worn?  
Tighten, replace or add clamp. (Keep extra  
seals on pump)  
Fittings/clamps are not sealed properly?  
Suction hose leaks at  
inlet.  
Hose diameter is too large?  
Pressure too high?  
Use smaller diameter hose or replace hose.  
Check pressure, add additional clamp.  
Check hose.  
Discharge does not stay  
on coupling.  
Hose kinked or end blocked?  
Open pump cover and clean dirt and debris  
from inside housing.  
Impeller jammed or blocked?  
Impeller does not turn:  
pump is hard to start.  
Adjust clearance by removing shim from  
behind impeller.  
Impeller and volute binding?  
Defective engine?  
See Engine Owner's Manual.  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXPLANATION OF CODE IN REMARKS COLUMN  
The following section explains the different symbols and  
QTY. Column  
remarks used in the Parts section of this manual. Use the  
help numbers found on the back page of the manual if there  
are any questions.  
Numbers Used — Item quantity can be indicated by a  
number, a blank entry, or A/R.  
A/R (As Required) is generally used for hoses or other  
parts that are sold in bulk and cut to length.  
NOTICE  
The contents and part numbers listed in the parts  
section are subject to change without notice.Multiquip  
does not guarantee the availability of the parts listed.  
A blank entry generally indicates that the item is not sold  
separately.Other entries will be clarified in theRemarks”  
Column.  
SAMPLE PARTS LIST  
REMARKS Column  
NO. PART NO. PART NAME  
QTY. REMARKS  
Some of the most common notes found in the “Remarks”  
Column are listed below. Other additional notes needed  
to describe the item can also be shown.  
1
2%  
12345  
BOLT......................1 .....INCLUDES ITEMS W/%  
WASHER, 1/4 IN............NOT SOLD SEPARATELY  
WASHER, 3/8 IN....1 .....MQ-45T ONLY  
2% 12347  
3
4
12348  
12349  
HOSE ..................A/R ...MAKE LOCALLY  
BEARING ..............1 .....S/N 2345B AND ABOVE  
Assembly/Kit — All items on the parts list with the  
same unique symbol will be included when this item is  
purchased.  
NO. Column  
Indicated by:  
Unique Symbols — All items with same unique  
symbol  
“INCLUDES ITEMS W/(unique symbol)”  
(@, #, +, %, or >) in the number column belong to the  
same assembly or kit, which is indicated by a note in the  
“Remarks” column.  
Serial Number Break — Used to list an effective serial  
number range where a particular part is used.  
Indicated by:  
Duplicate Item Numbers — Duplicate numbers indicate  
multiple part numbers, which are in effect for the same  
general item, such as different size saw blade guards in  
use or a part that has been updated on newer versions  
of the same machine.  
“S/N XXXXX AND BELOW”  
“S/N XXXX AND ABOVE”  
“S/N XXXX TO S/N XXX”  
Specific Model Number Use — Indicates that the part  
is used only with the specific model number or model  
number variant listed. It can also be used to show a  
part is NOT used on a specific model or model number  
variant.  
NOTICE  
When ordering a part that has more than one item  
number listed, check the remarks column for help in  
determining the proper part to order.  
Indicated by:  
“XXXXX ONLY”  
“NOT USED ON XXXX”  
PART NO. Column  
Numbers Used — Part numbers can be indicated by a  
number, a blank entry, or TBD.  
“Make/Obtain Locally” — Indicates that the part can  
be purchased at any hardware shop or made out of  
available items.Examples include battery cables, shims,  
and certain washers and nuts.  
TBD (To Be Determined) is generally used to show a  
part that has not been assigned a formal part number  
at the time of publication  
PAGE 26 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SUGGESTED SPARE PARTS  
QP2E PUMP WITH ROBIN EX130D51111 ENGINE  
1 to 3 units  
Qty.  
2
P/N Description  
KIT204.......................KIT, PUMP  
2
2
1
0631211100ASSY.....CAP, FLOODING WITH O-RING  
0480350300...............O-RING FLOODING CAP  
7204000030...............IMPELLER  
2
3
2773260308...............ELEMENT, AIR CLEANER  
0650140150...............SPARK PLUG  
3
1
1
2825011118...............ROPE, STARTER  
0430440050...............CAP, FUEL TANK  
X641360010 ..............FUEL FILTER  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PUMP ASSY.  
14  
19  
32  
17  
20  
29  
30  
6
18  
7
8
9
21  
15  
10  
11  
12  
13  
1
33  
24  
26  
28  
31  
PUMP  
KIT  
27  
25  
PAGE 28 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PUMP ASSY.  
NO.  
1
2
3
4
5
6
7%  
8%  
9%  
PART NO.  
EX130D51111  
7204100010  
PART NAME  
ENGINE, ROBIN  
CASING  
QTY.  
REMARKS  
1
1
1
1
4
4
1
1
72040001600014 SUCTION COVER NPT2”  
1889350351  
0181050820  
0191150520  
0489242100  
0489241780  
0803442320  
CHECK VALVE  
BOLT SET WITH WASHER, LOCK M8X20  
BOLT  
O-RING (CASING). DIA 2.4 X DIA. 210  
O-RING (VOLUTE CASING)  
MECHANICAL SEAL SILCON CARBIDE 1 SET  
10% 0852831600  
10% 0852851600  
ADJUST LINER DIA. 0.3 THICKNESS  
ADJUST LINER DIA. 0.5 THICKNESS  
IMPELLER 3/4”-16UNF  
1~3  
1~3  
1
11  
12  
7204000030  
1808000130  
VOLUTE CASING  
1
13% 1293330620  
VOLUTE CASING PACKING  
CASING COVER PACKING  
CASING COVER  
BOLT SET WITH WASHER, LOCK  
(DELIVERY ELBOW) M8 X 25  
DELIVERY ELBOW NPS2”  
BOLT SET WITH WASHER, LOCK  
1
1
1
6
14  
15  
16  
1211390610  
7204100020  
0181050825  
17  
18  
19  
20#  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
9246100090  
0181050820  
1
4
0631211100ASSY FLOODING CAP PF1.......................................1................INCLUDES ITEM W/ #  
0480350300  
0481310550  
0631211100ASSY DRAIN CAP PF1”  
0480350300 O-RING (DRAIN CAP)  
7204214010P002 BASE  
0105050840  
0209150080  
0723322030R  
0209150060  
O-RING (FLOODING CAP)  
O-RING (DELIVERY ELBOW)  
1
1
1
1
1
4
4
4
4
1
1
1
4
BOLT (ENGINE) M8 X 40  
FLANGE NUT (ENGINE) M8  
CUSHION RUBBER  
FLANGE NUT (CUSHION RUBBER) M6  
07904320200014 NIPPLE (DELIVERY) NPS2” X NPT2”  
0481310550  
0742303050  
0451250080  
KIT204  
O-RING (NIPPLE)  
STRAINER NPT2”  
WASHER, LOCK M8  
KIT, PUMP .........................................................1................INCLUDES ITEMS W/%  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — CRANKCASE ASSY.  
PAGE 30 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — CRANKCASE ASSY.  
NO.  
10  
PART NO.  
PART NAME  
CRANKCASE CP...............................................1................INCLUDES ITEMS W/ #  
QTY.  
REMARKS  
2761010241  
0440250200  
0600280021  
2771501103  
0440060020  
0401140030  
0211140020  
2771100221  
30#  
40#  
50#  
75#  
80  
OIL SEAL  
BALL BEARING  
PIPE KNOCK  
OIL SEAL  
PLUG  
1
1
2
1
1
1
90  
210  
GASKET  
MAIN BEARING COVER ...................................1................INCLUDES ITEMS W/ $  
220$ 0440250210  
230$ 0600250140  
OIL SEAL  
1
1
1
1
2
1
6
1
1
BALL BEARING  
GOVERNOR GEAR CP  
GOVERNOR SLEEVE  
OIL GAUGE  
GASKET (HEAD)  
FLANGE BOLT  
PIPE KNOCK  
250  
260  
270  
280  
300  
700  
960  
27745004J1  
2774190103  
2776360113  
0213160020  
0010408350  
2771501103  
2769900127  
GASKET SET  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — CRANKSHAFT, PISTON ASSY.  
PAGE 32 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — CRANKSHAFT, PISTON ASSY.  
NO.  
10  
50  
310  
PART NO.  
PART NAME  
CRANK SHAFT CP  
FLANGE NUT  
QTY.  
1
1
REMARKS  
2762100221  
0180140020  
2762250110  
CONNECTING ROD ASSY ...............................1................INCLUDES ITEM W/ #  
320# 2772300103  
CONNECTING ROD BOLT  
PISTON PIN  
PISTON  
PISTON RING SET  
CLIP  
2
1
1
1
2
350  
360  
370  
380  
2762330113  
27623401H3  
2762351117  
2152500403  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — GOVERNOR ASSY.  
PAGE 34 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — GOVERNOR ASSY.  
NO.  
10  
20  
30  
40  
50  
60  
70  
PART NO.  
PART NAME  
QTY.  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
REMARKS  
2774230123  
2774220133  
2794270111  
2774280123  
0031305000  
0130060240  
0186060020  
2774251013  
2774330303  
2774350203  
2774450103  
0217060070  
2774600202  
0023506000  
0110060020  
GOVERNOR LEVER  
GOVERNOR SHAFT  
GOVERNOR ROD CP  
ROD SPRING  
CLIP  
BOLT AND WASHER ASSY  
NUT  
GOVERNOR SPRING  
SPEED CONTROL LEVER  
STOP PLATE  
80  
310  
340  
350  
355  
435  
450  
485  
WASHER  
FRICTION WASHER  
SPEED CONT. BRKT UN  
SELF LOCK NUT  
FLANGE BOLT  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — CAMSHAFT ASSY.  
PAGE 36 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — CAMSHAFT ASSY.  
NO.  
10  
25  
27  
34#  
35#  
37#  
38#  
150  
160  
163  
166  
170  
PART NO.  
PART NAME  
CAM SHAFT CP ................................................1................INCLUDES ITEMS W/ #  
QTY.  
REMARKS  
2773160131  
2773510103  
0240060010  
2773860103  
2773640103  
2773650103  
2773870203  
2763560111  
2773691103  
2773710103  
2773690203  
2773691313  
PIN,CAMSHAFT  
O RING  
PIN, SPRING  
1
1
1
1
1
1
1
1
1
1
1
RELEASE LEVER  
CLIP  
RETURN SPRING  
TIMING CHAIN CP  
TENSIONER  
SPRING (TENSIONER)  
PIN (TENSIONER)  
CHAIN GUIDE  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — AIR CLEANER ASSY.  
PAGE 38 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — AIR CLEANER ASSY.  
NO.  
510  
PART NO.  
2773261110  
PART NAME  
QTY.  
REMARKS  
AIR CLEANER ASSY ........................................1................INCLUDES ITEMS W/ #  
BASE CP ...........................................................1................INCLUDES ITEMS W/ $  
PACKING  
COVER CP  
LABEL  
ELEMENT  
FLANGE NUT  
FLANGE BOLT  
200# 2773260118  
220#$ 2773260408  
250# 2773260208  
260#$ 2773260908  
520# 2773260308  
1
1
1
1
1
1
570  
580  
0023806000  
0110060050  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — COOLING, STARTING ASSY.  
PAGE 40 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — COOLING, STARTING ASSY.  
NO.  
10  
20  
40  
60  
61  
80  
81  
PART NO.  
PART NAME  
QTY.  
REMARKS  
2765120201  
0732005470  
0110060030  
2775271121  
2775270203  
0010406160  
0110060020  
0110060010  
2685020130  
BLOWER HOUSING CP  
LABEL (TRADE MARK)  
FLANGE BOLT  
BAFFLE 1 (CASE) CP  
BAFFLE 2 (HEAD)  
FLANGE BOLT  
1
1
4
1
1
1
1
4
FLANGE BOLT  
FLANGE BOLT  
220  
210  
RECOIL STARTER ASSY..................................1................INCLUDES ITEMS W/ #  
210-1# 2705011508  
210-2# 2695012008  
210-3# 2825011118  
210-4# 2615010008  
210-5# 2705012508  
210-6# 2275013108  
210-7# 2275013508  
210-8# 2705026108  
210-11# 2685014518  
210-49# 2275015208  
SPIRAL SPRING  
REEL  
STARTER ROPE  
STARTER KNOB  
RATCHET  
FRICTION SPRING  
RETURN SPRING  
RATCHET GUIDE  
STARTER PULLEY  
SET SCREW  
1
1
1
1
2
1
2
1
1
1
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — FUEL TANK ASSY.  
PAGE 42 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — FUEL TANK ASSY.  
NO.  
10  
20  
23  
30  
40  
48  
60  
63  
70  
90#  
PART NO.  
PART NAME  
QTY.  
REMARKS  
2766010201  
0732005181  
2769511103  
0430440050  
X641360010  
0505120020  
0023806000  
0110060130  
2766260301  
0561110050  
FUEL TANK CP  
LABEL (WARNING)  
LABEL (MODEL)  
FUEL TANK CAP CP  
FUEL FILTER  
UNION  
FLANGE NUT  
FLANGE BOLT  
1
1
1
1
1
1
2
1
FUEL PIPE CP...................................................1................INCLUDES ITEM W/ #  
HOSE CLAMP  
2
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — CARBURETOR ASSY.  
PAGE 44 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — CARBURETOR ASSY.  
NO.  
A
1#  
2#  
3#  
5#  
8#  
PART NO.  
PART NAME  
CARBURETOR ASSY .......................................1................INCLUDES ITEMS W/ #  
QTY.  
REMARKS  
2766230130  
1066253808  
2096235108  
2776252508  
2466242008  
2776252008  
2766253018  
2276245108  
2776250008  
2776251508  
2776250608  
2146245008  
2146254008  
2266250608  
2766244008  
2776240418  
2266270118  
2776236008  
1066255608  
2836235708  
2076241008  
1066241008  
2366254108  
2776255308  
2796210310  
2776211018  
2776210018  
2776255208  
1656237708  
2774380101  
27732902J1  
27735903J3  
27735902J3  
THROTTLE VALVE  
SCREW  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
CHOKE VALVE  
PILOT JET  
CHOKE LEVER  
THROTTLE SHAFT A  
BOLT  
NEEDLE  
PIN  
FLOAT BODY ASSY  
PACKING  
CHAMBER PACKING  
FLOAT  
MAIN NOZZLE  
MAIN JET  
CLIP  
BOLT  
SCREW  
SPRING  
AIR JET  
AIR JET (PILOT)  
PACKING  
NUT  
COCK BODY- A  
PACKING  
CUP  
O-RING  
SCREW  
CHOKE LEVER CP  
11#  
12#  
14#  
15#  
16#  
17#  
18#  
19#  
20#  
22#  
24#  
28#  
40#  
41#  
44#  
45#  
79#  
144#  
300#  
302#  
303#  
325#  
327#  
224  
540  
550$  
560$  
INSULATOR CP.................................................1................INCLUDES ITEMS W/ $  
GASKET 2 (INSULATOR)  
GASKET 1 (INSULATOR)  
1
1
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — FLYWHEEL ASSY.  
PAGE 46 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — FLYWHEEL ASSY.  
NO.  
10  
11  
30  
50  
100  
110  
PART NO.  
PART NAME  
FLYWHEEL CP  
IGNITION COIL CP  
BOLT AND WASHER ASSY  
WIRE 1 CP  
QTY.  
REMARKS  
2767923021  
2777943101  
0011406250  
27773101H1  
0650140150  
0655000270  
1
1
2
1
1
1
SPARK PLUG, NGK BR6HS  
SPARK PLUG CAP  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — MUFFLER ASSY.  
PAGE 48 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — MUFFLER ASSY.  
NO.  
310  
315  
317  
320  
340  
350  
360  
361  
365  
385  
387  
PART NO.  
PART NAME  
MUFFLER CP  
QTY.  
REMARKS  
27630111J1  
2773760101  
0150040060  
2763420101  
2773520113  
9802008280  
0152060090  
0110060010  
0110080320  
27737203H1  
0150040060  
1
1
1
1
1
2
2
1
1
1
2
SPARK ARRESTER CP  
TAPPING SCREW, M4X6L  
MUFFLER COVER CP  
GASKET (MUFFLER)  
FLANGE NUT  
TAPPING BOLT  
FLANGE BOLT  
FLANGE BOLT  
SCREEN CP  
TAPPING SCREW  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — CYLINDER HEAD ASSY.  
PAGE 50 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — CYLINDER HEAD ASSY.  
NO.  
20#  
26#  
60  
70  
80  
90  
95  
200  
PART NO.  
PART NAME  
VALVE GUIDE  
STEM SEAL  
VALVE SPRING  
SPRING RETAINER  
INTAKE VALVE  
EXHAUST VALVE  
COLLET- VALVE  
QTY.  
REMARKS  
2371420203  
2771601001  
2793360103  
2693370103  
27633401H3  
27633501H3  
13210KA031  
2773500201  
2
1
2
2
1
1
4
PIN (ROCKER) CP ............................................1................INCLUDES ITEM W/ $  
CLIP  
202$ 0031305000  
1
220  
225  
2773620100  
2773620200  
ROCKER ARM (IN) ASSY.................................1................INCLUDES ITEMS W/ %  
ROCKER ARM (EX) ASSY................................1................INCLUDES ITEMS W/ @  
230% 0149050020  
231@ 0149050020  
240% 0170050030  
241@ 0170050030  
ADJUST SCREW  
ADJUST SCREW  
NUT  
NUT  
FLANGE BOLT  
1
1
1
1
1
290  
610  
620  
630  
631  
0110060020  
2761300111  
2761500133  
0110080240  
0110080310  
CYLINDER HEAD CP........................................1................INCLUDES ITEMS W/ #  
GASKET (HEAD)  
FLANGE BOLT  
FLANGE BOLT  
STUD  
1
4
1
2
2
1
1
4
660# 0105080250  
670# 0105060351  
STUD  
680  
690  
710  
2771550301  
2771600113  
0110060020  
ROCKER COVER CP  
GASKET (ROCKER COVER)  
FLANGE BOLT  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — ACCESSORIES ASSY.  
PAGE 52 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROBIN EX130D51111 ENGINE — ACCESSORIES ASSY.  
NO.  
10  
PART NO.  
27790301H0  
PART NAME  
ACCESSORY TOOL KIT  
QTY.  
1
REMARKS  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TERMS AND CONDITIONS OF SALE — PARTS  
5. Parts must be in new and resalable  
condition, in the original Multiquip  
package (if any), and with Multiquip part  
numbers clearly marked.  
Multiquip reserves the right to quote and  
sell direct to Government agencies, and to  
Original Equipment Manufacturer accounts  
who use our products as integral parts of their  
own products.  
PAYMENT TERMS  
Terms of payment for parts are net 30 days.  
FREIGHT POLICY  
6. The following items are not returnable:  
All parts orders will be shipped collect or  
prepaid with the charges added to the invoice.  
All shipments are F.O.B. point of origin.  
Multiquip’s responsibility ceases when a  
signed manifest has been obtained from the  
carrier, and any claim for shortage or damage  
must be settled between the consignee and  
the carrier.  
a. Obsolete parts. (If an item is in the  
price book and shows as being  
replaced by another item, it is  
obsolete.)  
SPECIAL EXPEDITING SERVICE  
A $35.00 surcharge will be added to the  
invoice for special handling including bus  
shipments, insured parcel post or in cases  
where Multiquip must personally deliver the  
parts to the carrier.  
b. Any parts with a limited shelf life  
(such as gaskets, seals, “O” rings,  
and other rubber parts) that were  
purchased more than six months  
prior to the return date.  
LIMITATIONS OF SELLER’S LIABILITY  
MINIMUM ORDER  
Multiquip shall not be liable hereunder for  
damages in excess of the purchase price of  
the item with respect to which damages are  
claimed, and in no event shall Multiquip be  
liable for loss of profit or good will or for any  
other special, consequential or incidental  
damages.  
The minimum charge for orders from Multiquip  
is $15.00 net. Customers will be asked for  
instructions regarding handling of orders not  
meeting this requirement.  
c. Any line item with an extended  
dealer net price of less than  
$5.00.  
d. Special order items.  
RETURNED GOODS POLICY  
e. Electrical components.  
f. Paint, chemicals, and lubricants.  
g. Decals and paper products.  
h. Items purchased in kits.  
Return shipments will be accepted and  
credit will be allowed, subject to the following  
provisions:  
LIMITATION OF WARRANTIES  
No warranties, express or implied, are  
made in connection with the sale of parts or  
trade accessories nor as to any engine not  
manufactured by Multiquip. Such warranties  
made in connection with the sale of new,  
complete units are made exclusively by a  
statement of warranty packaged with such  
units, and Multiquip neither assumes nor  
authorizes any person to assume for it  
any other obligation or liability whatever in  
connection with the sale of its products. Apart  
from such written statement of warranty,  
there are no warranties, express, implied or  
statutory, which extend beyond the description  
of the products on the face hereof.  
1. A Returned Material Authorization  
must be approved by Multiquip prior to  
shipment.  
7. The sender will be notified of any material  
received that is not acceptable.  
8. Such material will be held for five  
working days from notification, pending  
instructions. If a reply is not received  
within five days, the material will be  
returned to the sender at his expense.  
2. To obtain a Return Material Authorization,  
a list must be provided to Multiquip  
Parts Sales that defines item numbers,  
quantities, and descriptions of the items  
to be returned.  
9. Credit on returned parts will be issued  
at dealer net price at time of the original  
purchase, less a 15% restocking  
charge.  
a. The parts numbers and descriptions  
must match the current parts price  
list.  
b. The list must be typed or computer  
generated.  
10. In cases where an item is accepted, for  
which the original purchase document  
can not be determined, the price will be  
based on the list price that was effective  
twelve months prior to the RMA date.  
c. The list must state the reason(s)  
for the return.  
Effective: February 22, 2006  
d. The list must reference the sales  
order(s) or invoice(s) under  
which the items were originally  
purchased.  
11. Credit issued will be applied to future  
purchases only.  
PRICING AND REBATES  
e. The list must include the name  
and phone number of the person  
requesting the RMA.  
Prices are subject to change without prior  
notice. Price changes are effective on a  
specific date and all orders received on or  
after that date will be billed at the revised price.  
Rebates for price declines and added charges  
for price increases will not be made for stock  
on hand at the time of any price change.  
3. AcopyoftheReturnMaterialAuthorization  
must accompany the return shipment.  
4. Freight is at the sender’s expense. All  
parts must be returned freight prepaid to  
Multiquip’s designated receiving point.  
PAGE 54 — QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
QP2E CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #0 (02/12/09) — PAGE 55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION AND PARTS MANUAL  
HERE’S HOW TO GET HELP  
PLEASE HAVE THE MODEL AND SERIAL  
NUMBER ON-HAND WHEN CALLING  
UNITED STATES  
Multiquip Corporate Office  
MQ Parts Department  
18910 Wilmington Ave.  
Carson, CA 90746  
Contact: [email protected]  
Tel. (800) 421-1244  
Fax (800) 537-3927  
800-427-1244  
310-537-3700  
Fax: 800-672-7877  
Fax: 310-637-3284  
Mayco Parts  
Warranty Department  
800-306-2926  
310-537-3700  
Fax: 800-672-7877  
Fax: 310-637-3284  
800-421-1244, Ext. 279  
310-537-3700, Ext. 279  
Fax: 310-537-1173  
Fax: 310-631-5032  
Service Department  
Technical Assistance  
800-421-1244  
310-537-3700  
Fax: 310-537-4259  
800-478-1244  
MEXICO  
UNITED KINGDOM  
MQ Cipsa  
Multiquip (UK) Limited Head Office  
Carr. Fed. Mexico-Puebla KM 126.5  
Momoxpan, Cholula, Puebla 72760 Mexico  
Contact: [email protected]  
Tel: (52) 222-225-9900  
Fax: (52) 222-285-0420  
Hanover Mill, Fitzroy Street,  
Ashton-under-Lyne,  
Lancashire OL7 0TL  
Tel: 0161 339 2223  
Fax: 0161 339 3226  
Contact: [email protected]  
CANADA  
Multiquip  
4110 Industriel Boul.  
Laval, Quebec, Canada H7L 6V3  
Contact: [email protected]  
Tel: (450) 625-2244  
Fax: (450) 625-8664  
© COPYRIGHT 2008, MULTIQUIP INC.  
Multiquip Inc and the MQ logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written permission. All other trademarks are the property  
of their respective owners and used with permission.  
This manual MUST accompany the equipment at all times. This manual is considered a permanent part of the equipment and should remain with the unit if resold.  
The information and specifications included in this publication were in effect at the time of approval for printing. Illustrations, descriptions, references and technical data contained in  
this manual are for guidance only and may not be considered as binding. Multiquip Inc. reserves the right to discontinue or change specifications, design or the information published  
in this publication at any time without notice and without incurring any obligations.  
Your Local Dealer is:  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Milan Technology Network Card MIL W0311 User Manual
Murray Lawn Mower 405000x8B User Manual
NEC Server Express320F User Manual
NetComm Network Router NP740N User Manual
Nikon Camcorder S800c User Manual
Niles Audio Network Router PAR4 User Manual
Nilfisk ALTO Vacuum Cleaner BA 410 User Manual
Ozaki Worldwide Speaker EM98933 User Manual
Panasonic Printer KX RC95 User Manual
Parker Hannifin Network Card OEM6250 User Manual