Moxa Technologies Network Card CP 114 Series User Manual

Industio CP-114 Series Users Manual  
3 in 1 RS-232/422/485 Industrial Serial Board for PCI Bus  
Fourth Edition, November 2004  
Moxa Technologies Co., Ltd.  
Tel:  
+886-2-8919-1230  
Fax: +886-2-8919-1231  
MOXA Technical Support  
Worldwide:  
The Americas  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MOXA Internet Services  
Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of  
our products, Moxa Internet Services has been set up to provide technical support, driver updates, product  
information, and user’s manual updates.  
The following services are provided  
E-mail for technical support............................... [email protected]  
World Wide Web (WWW) Site for product information:  
............................ http://www.moxa.com  
............................ http://www.moxa.com.tw  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About This Manual  
This manual is composed of six chapters and one appendix. This manual is written for installer, system administrator and  
software programmer.  
If you are a first-time installer and system administrator, we recommend you to go through the whole manual except  
Chapter 4.  
If you are a software programmer, you may refer to chapter 4, “Serial Programming Tools”.  
If you need cable wiring information, please see chapter 5, “Connection Cable and Cable Wiring”.  
If you encounter any problem during installation, please refer to chapter 6, “Troubleshooting”.  
Chapter 1 Introduction  
Overview and features for the Industio CP-114 Series are described. Also check list and overall installation guide.  
Chapter 2 Hardware Installation  
Hardware installation for the Industio CP-114 Series is detailed.  
Chapter 3 Software Installation  
Software installation, configuration, driver loading/unloading, driver upgrade and removal for various operating  
systems: Windows NT, Windows 95/98 and DOS.  
Chapter 4 Serial Programming Tools  
Roughly describing the programming tools for various O.S. platforms, including PComm under Windows NT and  
Windows 95/98, and API-232 under DOS. Also RS-485 programming issue is covered.  
Chapter 5 Connection Cable and Cable Wiring  
Describing the RS-232 and RS-422/485 cable wiring.  
Chapter 6 Troubleshooting  
Describing the problems and possible answers for the Industio CP-114 Series.  
Appendix  
Specification details, PCI, UART and DB37 pinouts are described.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
1
Introduction  
Overview  
Industio - Industrial Multiport Async Solutions for PCI  
The term Industio stands for smart multiport serial I/O solution for industrial applications. The  
Industio CP-114 Series boards, including CP-114, CP-114I, CP-114S and CP-114IS, are  
RS-232/RS-422/RS-485 4-port serial communication interface boards for 32-bit PCI bus with “Plug  
and Play” feature. The Industio CP-114 Series support all three serial interfaces, RS-232, RS-422  
and RS-485, in one board. Two of the four ports are RS-422/485 ports and the other two ports can be  
configured to RS-232 or RS-422/485 individually. Each RS-422/RS-485 port can control up to 32  
devices in a multidrop environment. With this versatile design, it can control different kinds of serial  
device, such as modems, CNC and other industrial machines, without the need to use interface  
converters.  
PCI Solution  
The board complies with PCI Spec. 2.1 and has neither switch nor jumper. The BIOS automatically  
assigns the hardware configuration for the IRQ number and memory addresses. Hence, the board  
MUST be plugged first before installing the software driver. For more PCI information, please refer  
to the Appendix, “Technical Reference”.  
Automatic Data Direction Control for RS-485  
To ease the 2-wire RS-485 half-duplex control, Automatic Data Direction Control intelligence is  
built on Industio CP-114 Series board. Eliminating the need of software interference. Hence, the  
applications can manage the RS-485 port without extra code to control the half-duplex protocol.  
With a well-designed and fine-tuned device driver, the Industio CP-114 boards make full use of the  
32 byte Tx/Rx FIFO and on-chip H/W flow control, so that they can transfer data without loss even  
at high speed such as 921.6, bps. The offer a reliable and high performance solution for serial  
multiport communications.  
JP5:Interface selection Jumper for Port 1  
JP6:Interface selection Jumper for Port 2  
SW2  
SW1  
RS-422  
RS-485  
JP5  
RS-232  
RS-232  
SW1: RS-422/RS-485 Selection Switch for Port 1/2/3/4  
SW2: Data Mode Switch for Port 1/2/3/4  
AUTO  
RS-485  
O
N
O
N
1
2
3
4
1
2
3
4
RS-422  
RS-485  
JP6  
By RTS  
RS-422  
JP  
1
JP  
2
JP1/2/4/3:Termination Resistor Jumper for Port 1/2/4/3  
Industio CP-114 Series Board  
Termination Resistors Ready for RS-422/RS-485  
Termination Resistors are already installed on the Industio CP-114 Series bodards and no more  
headaches for finding proper resistors and connecting them for impedance matching problem. More  
details are in chapter, “Connection Cable and Cable Wiring”.  
Industio CP-114 User's Manual 1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Operating System Support  
Support for Windows NT, Windows 95/98 and DOS with user-friendly installation, configuration  
and performance.  
MOXA Serial Comm Tools  
For application development, MOXA provides an easy-to-use serial communication library under  
Windows NT, Windows 95/98 (PComm) and DOS (API-232). Users can use this library to develop  
your own applications using Microsoft C, Turbo C, Assembly, QuickBASIC, Turbo Pascal, Clipper,  
Visual Basic, Visual C++, Borland Delphi, etc. Utilities, such as diagnostic, monitor, terminal  
emulator, etc., are included for debugging or monitoring the communication status or terminal  
emulator, or even file transferring.  
Surge/Isolation Protection  
To meet the demand of high reliability in industrial environment and to prevent the boards from  
damage caused by lighting or high potential voltage, an optical isolation option (2KV DC) and surge  
block option (25KV ESD) are available. This is critical to harsh environment such as factory.  
Broad Applications  
The board is suitable for many applications. Here are a few:  
! Multipoint data acquisition  
! Factory automation  
! Remote serial device control  
! Industrial control  
! Embedded industrial machine  
! SCADA  
Features  
The Industio CP-114 Series features:  
"
"
Support PCI, Plug and play, no switch, no jumper, easy installation  
Support all three serial interfaces in one board (Port 1,2 for RS-232 or RS-422/485; Port 3,4 for  
RS-422/485).  
"
"
Compact size design, (half-size).  
High speed 16C550C Communication Controllers with on-chip hardware flow control  
guarantees no data loss and data integrity.  
"
"
"
High speed up to 921.6K bps each port.  
Support optical isolation, max. 2000V (RS-422/485)  
Support surge protection (25KV ESD) for all signal lines to prevent interference and noise and  
protect your system and minimize the system down time.  
Support 2-wire RS-485 half-duplex operation.  
Automatic Data Direction Control (ADDC) intelligence to simplify the RS-485 software  
programming.  
"
"
"
"
"
"
RS-485 data control: Auto (ADDC) or by RTS.  
Termination Resistors already installed on-board, no headache for impedance matching.  
Compatible with PC standard COM ports.  
Powerful Serial Comm toolPcomm and API-232.  
"
Support popular OSWindows NT, Windows 95/98 and DOS  
CP-114 Series  
Windows NT  
Windows 95/98  
DOS  
:  
Driver supported by Moxa and shipped with product  
Note: Download the newest drivers from the MOXA FTP service  
1-2 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Introduction  
Check List  
Upon unpacking the Industio CP-114 Series, you should find items in the package:  
"
"
Industio CP-114 Series 4 ports serial board×1  
MOXA Software CD-ROM×1, which includes:  
!
!
!
!
Drivers for MOXA Multiport Async Products  
PComm Lite programming library and utilities for Windows NT/95/98  
API-232 programming library and utility for DOS  
User’s Manual (PDF)  
"
"
Industio CP-114 Series User’s Manual (This manual)  
Fan out cable DB37 to 4× DB9 (Male)  
Installation Guide  
This section gives a brief summary of how to install the Industio CP-114 Series under each  
supported operating system. The installation is simple and involves the following stages:  
Check the PCI BIOS settings  
Install the Industio CP-114 Series board  
and the connection cable  
See Chapter 2  
Install the software from the CD-ROM  
Configure the driver for the board and ports  
See respective O.S. Section  
in Chapter 3  
Connect the devices with the cable  
See Chapter 5 for cable wiring  
Restart the system  
See Chapter 3 “Software  
Installation”  
Check the driver initialization status  
If the system restart successfully, you may  
develop your applications or  
See Chapter 4, “Serial  
Programming Tools”  
execute the desired applications  
Industio CP-114 User's Manual 1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
1-4 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
2
Hardware Installation  
The installation of the Industio CP-114 Series consists of hardware and software installation. The  
respective sections of the operating systems in the next chapter deal with the software installation.  
The hardware installation is detailed in this chapter.  
JP5:Interface selection Jumper for Port 1  
JP6:Interface selection Jumper for Port 2  
SW2  
SW1  
RS-422  
RS-485  
JP5  
RS-232  
RS-232  
SW1: RS-422/RS-485 Selection Switch for Port 1/2/3/4  
SW2: Data Mode Switch for Port 1/2/3/4  
AUTO  
RS-485  
O
N
O
N
1
2
3
4
1
2
3
4
RS-422  
RS-485  
JP6  
By RTS  
RS-422  
JP1  
JP2  
JP4  
JP3  
JP1/2/4/3:Termination Resistor Jumper for Port 1/2/4/3  
Industio CP-114 Series Board  
First Thing to Do: Interface Settings  
Before installing the board into the slot, you should set all the jumpers to what you want. The  
default (factory) settings: Port 1, Port 2, Port 3 and Port 4 RS-485, Automatic Data Direction  
Control mode, no Termination Resistor, indicated as *.  
!
JP5/6 Interface Selection Jumper for Port 1/2:  
Left *  
Right  
Set the port interface to RS-422/RS-485.  
Set the port interface to RS-232.  
!
S1 RS-422/485 Selection Switch for Port 1/2/3/4:  
ON *  
OFF  
Set the port interface to RS-485.  
Set the port interface to RS-422.  
Industio CP-114 User's Manual 2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
!
!
S2 Data Mode Selection Switch for Port 1/2/3/4:  
(Valid if JP5/6 is Left and S1 is ON)  
ON*  
OFF  
Set the RS-485 port to Automatic Data Direction Control Mode.  
Set the RS-485 port to By RTS Mode.  
JP1/2/3/4 Termination Resistor Port 1/2/3/4:  
(Valid if JP5/6 is Left and S1 is ON)  
Open * Not using Termination Resistor  
Short  
Using Termination Resistor  
Installing the Industio CP-114 Series Board  
The BIOS automatically assigns the IRQ number and I/O addresses for the Industio CP-114 Series  
board. Hence, it is a must to have the board plugged first before installing the software driver. After  
this, simply install the control board into the PC and then connect the connection cable.  
Step 1: Power off the PC.  
Warning ! Make sure your system is switched off before you start installing any  
board. If you don’t, you may risk damaging your system and the board.  
Step 2: Remove the slot cover bracket if present.  
Step 3: Plug the Industio CP-114 Series control board firmly into a free 32-bit PCI slot.  
Step 4: Fasten the holding screw to fix the control board in place.  
Connecting the Fan-out Cable  
Step 5: Connect the fan-out cable (DB37 to DB9 x 4).  
SW2  
SW1  
RS-422  
RS-485  
JP5  
RS-232  
RS-232  
AUTO  
RS-485  
O
N
O
N
1
2
3
4
1
2
3
4
RS-422  
RS-485  
JP6  
By RTS  
RS-422  
JP1  
JP2  
JP4  
JP3  
Fan-out Cable Industio CP-114  
Step 6: Power on the PC and the BIOS will automatically set the IRQ and I/O address.  
Note ! Each board must occupy one unique IRQ and four 8-byte I/O addresses,  
which are assigned automatically by the BIOS. However, you can select a  
free IRQ number manually via the PC’s BIOS setup for the PCI slot, but  
normally this method is not available for the I/O address. The possible IRQ  
numbers are 2, 3, 4, 5, 7, 10, 11, 12, and 15. The possible I/O addresses are  
from 0x0000 to 0xFFFF.  
Step 7: Proceed with the software installation detailed in the next chapter, “Software  
Installation”.  
2-2 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3
3
Software Installation  
In this chapter, the software driver installation, configuration and driver update/removal procedures  
are described for various operating systems, including Windows NT, Windows 95/98 and DOS.  
Before proceeding with the software installation, complete the hardware installation detailed in  
previous chapter.  
However, if it is necessary for you to develop your own applications, please refer to the next chapter,  
“Serial Programming Tools”, for serial programming issues.  
Windows NT  
Windows NT supports up to 256 serial ports, from COM1 to COM256. To fully integrate the  
advanced features of Windows NT, multi-process and multi-thread, pure 32-bit Windows NT device  
drivers are developed for the Industio CP-114 Series and other MOXA multiport boards. The drivers  
conform to Win32 COMM API standard.  
If you install the driver for the first time, please go directly to the section “Installing Driver”.  
If you have already installed the driver and want to re-configure the board and port, please refer to  
the section, “Configuring Board and Port”.  
If you have already installed the driver and want to add or delete boards, please refer to the section,  
“Adding/Removing Board”.  
If you want to update or even remove the driver, please go to the section, “Updating Driver”, or the  
section, “Removing Driver”.  
Installing Driver  
Following is the procedure for installing the Industio CP-114 Series driver for the first time under  
Windows NT 3.51/4.0. Make sure the board(s) has(have) already been plugged in the system PCI  
slot(s).  
1. Please log in NT as Administrator.  
2. Open the [Control Panel], click on the [Network] icon and select the [Adapters] tab.  
3. Click on the [Add] button, then the [Have Disk...] button in “Select Network Adapter”.  
4. Specify the exact path of the driver diskette, A:\WINDOWS.NT. Then click [OK].  
Industio CP-114 User's Manual 3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5. Select “MOXA Smartio/Industio Family multiport board” in the “Select OEM Option” dialog  
box, and click [OK] to enter the “Moxa Smartio/Industio Configuration Panel” dialog box to  
start the installation.  
3-2 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Software Installation  
6. In the “Moxa Smartio/Industio Configuration Panel” dialog box, click [Add] to enter  
Property” dialog box to add the Industio CP-114 Series board. Select the “CP-114 Series” in  
the “Board Type” field. In the “Property” dialog box, the COM number field of the newly  
installed board is set to default COM No. If necessary, you may select to change all the ports of  
the board with the desired “COM Number”.  
Note !  
You may go directly to the step 8 if you need not change any setting.  
7. In the “Property” dialog box, select the desired port in the port list and click [Port Setting] to  
enter the individual “Port #” setting dialog box to change the port number mappings or FIFO  
settings.  
!
Port Number  
You have to set up all the ports of the board with the desired “COM number”, which  
should not conflict with other COM number in use. In this “Individual Port Setting”  
dialog box, you may have two ways to map the physical ports to COM numbers  
depending on the check box “Auto Enumerating COM Number”.  
If “Auto Enumerating COM Number” is checked and specify the COM number of the  
first port, subsequent ports are mapped to continuous COM numbers. For instance, if first  
port is mapped to COM3, then second port is mapped to COM4 sequentially.  
If “Auto Enumerating COM Number” is not checked, specify the COM number for  
individual port. For instance, the second port can be out of sequence, say COM10, while  
the first port is mapped to COM3.  
!
Rx FIFO Trigger  
Industio CP-114 User's Manual 3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rx FIFO trigger levels, at 1, 4, 8 or 14 bytes, are available, and the default value is 14  
bytes.  
!
Tx FIFO Size  
Tx FIFO sizes from 1 to 16 bytes are available, and the default value is 16 bytes.  
8. Click [OK] in the “Port #” and the “Property” dialog boxes to go back to the “Moxa  
Smartio/Industio Configuration Panel” dialog box.  
Note !  
If you need to install more than one board, click [Add] and repeat steps 6 to 8 to  
configure another board. Up to four Industio CP-114 Series boards can be installed  
in a system.  
Click [OK] to finish the configuration.  
9. When configuration is done, click on [Close] button in the “Network Settings” dialog box.  
10.Restart Windows NT system. The latest configuration will not take effect unless the system  
restarts.  
Note ! The latest configuration will not take effect unless the system restarts.  
11. Once the system restarts, you may check the event log issued by the MOXA driver to see if the  
ports of the board are initialized successfully.  
!
Enter the [Administrative] group, click on the [Event Viewer] icon and select [Log] and  
[System] to check a message similar to “MOXA CP-114, with first serial port COM3, has  
been enabled” for each configured board.  
!
If an error message similar to “Cannot find any configured MOXA CP-114 board!”  
appears, refer to the “Troubleshooting” chapter for solutions.  
3-4 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Software Installation  
Note ! Once the board and the driver are installed and the driver restarts successfully, you  
can start to develop applications with the PComm library (See “Serial Programming  
Tools”) or the Microsoft Win32 API. You can also execute any ready-made  
applications, such as PComm utility Terminal emulator (See “Serial Programming  
Tools”) or HyperTerminal to transmit/receive data, as well as Remote Access  
Service to provide dial-up networking capabilities.  
Configuring Board and Port  
If you already have installed the driver and want to re-configure the ports, please follow this  
procedure.  
1. In the [Control Panel], click on the [Network] icon and select the [Adapters] tab.  
2. Select “MOXA Smartio/Industio Family Adapter” in “Network Adapters”.  
3. Click on the [Properties] button to open the “Moxa Smartio/Industio Configuration Panel”  
dialog box. Please see steps 6-10 in the previous section, “Installing Driver”, for more details.  
Adding/Removing Board  
Following is the procedure to add/remove Industio CP-114 boards after a first time installation. Note  
that the presence of the board(s) is(are) required for adding/removing boards.  
1. Power off the system.  
2. Plug/unplug the boards in the system.  
3. Power on the system.  
4. Run the software configuration to setup the boards, as shown in the previous section.  
Updating Driver  
To update the driver for the Industio CP-114 board, simply remove the driver, as described in the  
next section, and then reinstall it as detailed in the “Installing Driver” section.  
Industio CP-114 User's Manual 3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Removing Driver  
To remove the driver for the Industio CP-114 board,  
1. Open the [Control Panel], click on the [Network] icon, and select the [Adapters] tab.  
2. Select “MOXA Smartio/Industio Family Adapter” in the adapter list, then click on the  
[Remove] button and the [OK] button to remove the driver.  
3. Restart the system to activate the new configuration.  
Windows 95/98  
Windows 95/98 supports up to 128 serial ports, from COM1 to COM128. To fully integrate the  
advanced features of Windows 95/98, multi-process and multi-thread, pure 32-bit Windows 95/98  
virtual device port drivers (VxD) compliant with communication drivers (VCOMM) are developed  
for the Industio CP-114 Series and other MOXA multiport boards. The drivers conform to the  
Win32 COMM API standard.  
If you install the driver for the first time, or you want to add more boards, please go directly to  
section, “Installing Driver”.  
If you have already installed the driver and want to re-configure the board, please refer to section,  
“Configuring Board and Port”.  
If you want to update the driver, please go to section, “Updating Driver”.  
If you want to remove the driver, please go to the section, “Removing Driver”.  
Installing Driver  
If you install for the first time, or you want to add more boards, this section is for you.  
You can easily plug the Industio CP-114 board and work right away with very little installation  
efforts under Windows 95/98, which supports Plug and Play capability. Windows 95/98 will  
automatically detect the presence of the newly plugged board and prompt you to install the software  
driver the first time. In this case, you need the driver diskette.  
Up to 4 Industio CP-114 Series boards can be installed together as long as the I/O addresses and IRQ  
number resources are sufficient and available in a system.  
3-6 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Software Installation  
The following flow chart illustrates the driver installation stages of the Industio CP-114 Series  
boards. Each stage is detailed later.  
See chapter “Hardware  
Installation”  
Install the Industio PCI board in the system  
Start Windows 95/98 to detect the board  
Yes  
Driver installed before?  
No  
Install the driver with the diskette  
See “First Time Driver Installation  
Stage”  
Configure the port  
See “Port Configuration Stage”  
The ports of the Industio CP-114 Series  
board are ready to work.  
See “Board and Port Ready Stage”  
First Time Driver Installation Stage  
This stage presents the steps for installing the driver for the very first time with the first Industio  
CP-114 Series board. The installation of the Industio CP-114 Series board for Windows 95 and  
Windows 98 differs slightly and will be described in two columns. Follow the steps in the left or  
right column for Windows 95 or 98, respectively.  
1. Upon detecting the first new Industio CP-114 Series board, Windows 95/98 will  
automatically show a “New hardware found” message box, and then display the following  
dialog box. Click on the [Next>] button.  
Industio CP-114 User's Manual 3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Industio CP-114 User's Manual 3-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Software Installation  
Windows 95  
Windows 98  
2.  
Click on the [Other Locations] button.  
2.  
Select “Display a list...” and click [Next>].  
3. Type “A:\Windows.95” in the Location field, and  
click [OK] button. The system will start reading the  
files from the diskette.  
3. Select “Other Devices” and click [Next>] button.  
4. Clink on the [Finish] button.  
4. Click on the [Have Disk] button.  
Industio CP-114 User's Manual 3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Type “A:\Windows.95” and click [OK] button. The  
system will start reading the files from the diskette.  
6. Click [Next>] button.  
7. Click [Next>] button.  
Port Configuration Stage  
This stage displays the “CP-114 Series Installation” dialog box for the port configuration. Here  
you can map the MOXA ports to the system COM numbers.  
In the “CP-114 Series Installation” dialog box, the COM number field of the newly installed board  
is set to default COM No. If necessary, you may select to change all the ports of the board with the  
desired “COM Number”.  
Note ! You may go directly to the next stage if you need not change any setting.  
3-10 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Software Installation  
In the “CP-114 Series Installation” dialog box, select the desired port in the port list and click  
[Port Setting] to enter the individual “Port #” setting dialog box to change the port number  
mappings or FIFO settings.  
!
Port Number  
You have to set up all the ports of the board with the desired “COM number”, which should  
not conflict with other COM number in use. In this “Individual Port Setting” dialog box, you  
may have two ways to map the physical ports to COM numbers depending on the check box  
Auto Enumerating COM Number”.  
If “Auto Enumerating COM Number” is checked and specify the COM number of the first  
port, subsequent ports are mapped to continuous COM numbers. For instance, if first port is  
mapped to COM3, then second port is mapped to COM4 sequentially.  
If “Auto Enumerating COM Number” is not checked, specify the COM number for  
individual port. For instance, the second port can be out of sequence, say COM10, while the  
first port is mapped to COM3.  
!
!
Rx FIFO Trigger  
Rx FIFO trigger levels, at 1, 4, 8 or 14 bytes, are available, and the default value is 14 bytes.  
Tx FIFO Size  
Tx FIFO sizes from 1 to 16 bytes are available, and the default value is 16 bytes.  
Industio CP-114 User's Manual 3-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Board and Port Ready Stage  
Click [OK] for all the dialog boxes to finish the configuration and exit the “CP-114 Series  
Installation” dialog box.  
In this last stage, you will complete the driver installation.  
Windows 95  
Windows 98  
After the port installation, you can immediately use the  
COM ports of the Industio CP-114 Series board without  
restarting Windows 95 system.  
After the port installation, click on the [Finish] button. Now  
you can immediately use the COM ports of the Industio  
CP-114 Series board without restarting Windows98  
system.  
Once the installation is finished, error conditions of the board, if any, are displayed on the screen.  
Otherwise, everything should be fine.  
If an error message similar to “CP-114 (BusNo=x, DevNo=x, Port1=COMx) interrupt number is  
invalid!” appears, refer to the “Troubleshooting” chapter for solutions.  
Note ! Up to now, the driver installation of the Industio CP-114 Series is complete and  
successful, including the board and port configuration. However, if changes of the  
board and port configuration are needed, please refer to the next section, “Configuring  
Board and Port”, for more configuration details.  
Note ! Once the board and the driver are installed and the driver restarts successfully, you can  
start to develop applications with the PComm library (See “Serial Programming Tools”)  
or the Microsoft Win32 API. You can also execute any ready-made applications, such as  
PComm utility Terminal emulator (See “Serial Programming Tools”) or HyperTerminal  
to transmit/receive data, as well as Remote Access Service to provide dial-up  
networking capabilities.  
If multiple boards are installed at the same time, the same scenario applies for the next boards,  
except that no driver diskette is asked anymore.  
Similarly, if you want to add more boards and the driver has been installed before, simply plug the  
Industio CP-114 Series board and Windows 95/98 will automatically detect and install the  
required driver.  
3-12 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Software Installation  
Configuring Board and Port  
If you already have installed the driver and want to re-configure the COM number for the ports  
under Windows 95/98, follow this procedure.  
1. Open the [Control Panel], click on the [System] icon, select the [Device Manager] tab, and  
then [MOXA Smartio/Industio multiport board]. Select the desired [CP-114 Series] entry,  
click on the [Properties] button and select the [Ports Configuration] tab.  
#
2. Assign the desired COM number for the Industio CP-114 Series port mapping or FIFO settings,  
detailed in the stage, “Port Configuration Stage”, of the previous section, “Installing Driver”.  
3. Restart the system to activate the latest configuration.  
Industio CP-114 User's Manual 3-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Updating Driver  
This section explains how to update the driver.  
1. In the [Control Panel], click on the [System] icon, select the [Device Manager] tab and select  
[MOXA Smartio/Industio multiport board].  
2. Select the “CP-114 Series” option. Click on the [Properties] button and then select the [Driver]  
tab.  
3. Click on the [Update Driver...] button. Click then on the [Have Disk...] button to type the path  
of the new driver and update the driver.  
4. Restart the system to activate the new configuration.  
#
3-14 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Software Installation  
Removing Driver  
This section explains how to remove the Industio CP-114 Series board driver.  
1. Open [Control Panel] icon, double click [Add/Remove Programs] icon, and then select  
[Install/Uninstall] tab.  
2. Click on MOXA Smartio/Industio Driver option and then click [Add/Remove] button to start the  
driver removal.  
3. Click [Yes] button in the following shown message box to confirm the driver removal.  
4. Click [OK] button in Add/Remove Programs Properties dialog box.  
Industio CP-114 User's Manual 3-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DOS  
MOXA DOS API-232 is a software package that assists users to develop and/or debug programs for  
serial communications. This section will show you how to install the package, how to setup up the  
driver, and how to load or unload driver.  
For details of the serial programming (API-232 Library) and utilities, please refer to the next chapter,  
“Serial Programming Tools”.  
Installing Driver  
Run the installation program, DOSINST.EXE, in the DOS driver diskette. Specify the target  
API-232 directory (e.g. C:\MOXA) where software driver will be copied. Press F2 to start the  
installation.  
After installation is complete, you will be prompted to proceed running setup program. It is strongly  
recommended to do so.  
Industio CP-114 User's Manual 3-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Software Installation  
Driver Setup  
The following are steps for setting up the Industio CP-114 Series driver. Note that it is not intended  
to illustrate all the convenient functions of the setup programs when configuring the boards.  
1. Run the setup program, BIN\SETUP.EXE, in the API-232 directory.  
2. Press Enter to pop up the SETUP dialog box. In the SETUP dialog box, select the “CP-114  
Series” in the “Type” field and set up all the ports of the board with the desired “Port number”,  
which should not conflict with other port number in use.  
Industio CP-114 User's Manual 3-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Note ! Up to now you have completed the setup for Industio CP-114 Series board. You may  
skip this step and go directly to the next step 5 if you need not change any setting or  
configure any board.  
3.  
3. You may now enter/modify each port’s configuration. These displayed values are the port initial  
values as driver is loaded.  
Legend:  
Port number:  
3-18 Industio CP-114 User's Manual  
Some noticeable fields and functions are explained below.  
This is actually the port ID of each port. The application software will  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Software Installation  
refer to the port by its port number (ID). Duplicated port number is not  
allowed. That is, each MOXA serial port is referred to as port number in  
terms of serial programming.  
You may map the port number range to the one you prefer between 0 and  
255 as long as no port number overlapping condition or port number  
undefined condition occurs. Generally, you should take the convenience  
of programming into consideration when specifying the port numbers for  
the board.  
TxD buf size:  
RxD buf size:  
The transmit (output) buffer allocated in the system for each port.  
The receive (input) buffer allocated in the system for each port.  
F5: Group edit: This is a convenient function that helps you edit the configuration of  
several ports at one time as a group.  
4. To setup more boards, please follow the same instructions 2 to 3 described above.  
5. Press F10 to save the latest configuration and exit the SETUP program.  
Industio CP-114 User's Manual 3-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Loading Driver  
Having completed the setup, you can load the driver, "BIN\DP-DRV.EXE", at the DOS prompt.  
The driver will detect the Industio CP-114 Series board automatically. If the board(s) is(are)  
detected, a message similar to below will show:  
Smartio/Industio Family DOS driver Version 1.1  
Setup driver….  
CP-114 series (Bus=0, Dev=11): O.K.!  
Device driver setup O.K.  
It means the Industio CP-114 Series driver is installed properly. At this point, you are ready to  
execute application that supports API-232 functions, or start developing applications using API-232  
library.  
If something went wrong, for instance, the board does not match the configuration or the board is  
missing, the screen will show a message like:  
Smartio/Industio Family DOS driver Version 1.1  
Setup driver….  
CP-114 series (Bus=0, Dev=11): Board not Found.!  
Setup none port !!  
It means the Industio CP-114 Series driver is not installed properly. Please refer to chapter,  
“Troubleshooting”, for possible reasons and solutions.  
Unloading Driver  
To unload (release) the Industio CP-114 Series driver from memory, type "DP-DRV/Q" at the DOS  
prompt.  
3-20 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4
4
Serial Programming Tools  
Moxa supports some easy but powerful serial programming libraries and communication  
troubleshooting utilities under Windows NT and Windows 95/98. You will save a lot of developing  
time with the MOXA Serial Programming Tools.  
The following sections will detail the installation, the library and the utilities for various platforms.  
PComm, the professional serial comm tool for PC, is a software package for Windows NT and  
Windows 95/98. It consists of a powerful serial communication library for easy programming in the  
most popular languages, useful utilities such as diagnostic, monitor and terminal emulator,  
illustrative sample programs and comprehensive on-line documents.  
The serial communication library is useful for developing a system for data communication, remote  
access, data acquisition or industrial control in the Windows NT and Windows 95/98 environment,  
for an easier solution compared to the more complex Windows Win32 COMM API.  
PComm Installation  
To install PComm, run \Setup.exe from the diskette. Note that the PComm diagnostic and monitor  
utilities are for MOXA boards only. MOXA Windows NT or Windows 95/98 device drivers, as well  
as MOXA boards are required. The drivers are installed separately and detailed in the “Software  
Installation” chapter.  
Click [Start] and select [Program Files] and the [PComm Lite] group to see a list of utilities and  
documents.  
PComm Programming Library  
The serial communication library helps you to develop programs for serial communications for any  
COM port complying with Microsoft Win32 API. It facilitates the implementation of multi-process  
and multi-thread serial communication programs and hence greatly reduces developing time.  
For a complete library function description and sample programs for Visual C++, Visual Basic and  
Delphi, please click [Start] and select [Program Files] and [PComm Lite] and [PComm Library  
Help], [PComm Porting Notes] or [PComm Programming Guide] or refer to the sample  
programs in the PComm directory.  
Industio CP-114 User's Manual 4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Utilities  
Following are short descriptions of each utility. For details, please see the on-line help on the  
diskette.  
Diagnostic (for MOXA boards only)  
A convenient diagnostic program that provides internal and external testing, such as IRQ, TxD/RxD,  
UART, CTS/RTS, DTR/DSR, DTR/DCD testing, etc., for the MOXA boards and ports to verify  
correct operations of both the software and hardware.  
Click [Start] and select [Program Files] and [PComm Lite] and [Diagnostic].  
4-2 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Serial Programming Tools  
Monitor (for MOXA boards under Windows NT Only)  
A useful port status monitoring program that allows you to watch the selected MOXA COM ports’  
data transmitting/receiving throughput and communication line status which are updated and  
displayed on the screen at time intervals. You can also click on one of the specific displayed port in  
order to visualize the current communication parameters and status of that port.  
Click [Start] and select [Program Files] and [PComm Lite] and [Monitor].  
Industio CP-114 User's Manual 4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terminal Emulator  
The Terminal Emulator features multi-windows and supports terminal types of VT100 and ANSI.  
You can transfer data interactively, send pattern periodically or transfer file using ASCII,  
XMODEM, YMODEM, ZMODEM and KERMIT protocols.  
Click [Start] and select [Program Files] and [PComm Lite] and [Terminal Emulator].  
4-4 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Serial Programming Tools  
DOS  
Installing API-232  
API-232 Library is the professional serial programming tool for DOS. It is installed automatically  
along with the MOXA DOS drivers. The installation is detailed in Chapter "Software Installation".  
DOS API-232 Library  
DOS API-232 library supports languages like Microsoft C, Turbo C, Macro Assembly, QuickBasic,  
Turbo Pascal, Clipper, etc. Sample programs for each supported language are included, and placed  
in the sub-directory, ..\EXAMPLE\language ,of the API-232 directory.  
In addition, for DOS C language only, there are also Modem Control and File Transfer library  
available, supporting Hayes compatible modem control as well as ASCII, KERMIT, XMODEM,  
YMODEM and ZMODEM file transfer protocol functions.  
For complete API-232 function description, please see file API-232.TXT in the API-232 directory  
for more details.  
Utilities  
There are two utilities available for DOS: Data Scope and Diagnose, which are detailed below.  
Industio CP-114 User's Manual 4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Data Scope  
The Data Scope, BIN\SCOPE.EXE, is a suite of utility programs that can help users with system  
troubleshooting and serial communication debugging.  
There are three major functions in Data Scope utility:  
1. The Data Scope utility offers transparent monitoring of serial communication lines and allows data  
to be streamed to disk storage for later analysis.  
2. The TTY terminal emulation utility allows user to view the signal status and transfer data  
interactively or files using ASCII, XMODEM, YMODEM, ZMODEM and KERMIT protocols.  
3. The Diagnostic test utility provides port connection test with two MOXA ports connected via a  
properly wired cable.  
Please see on-line help as running BIN\SCOPE.EXE for more usage and capability information.  
Diagnose  
The Diagnose, BIN\PCIDIAG.EXE, is a utility that can help users to diagnose the hardware  
condition of each port of the selected board. See on-line help for more details.  
4-6 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Serial Programming Tools  
RS-485 Programming  
If you intend to do RS-485 communication with Industio CP-114 Series, please follow the RS-485  
programming guide below and also refer to the chapter, “Connection Cable and Cable Wiring”,  
for more RS-485 operation details.  
The Industio CP-114 Series supports only 2-wire half-duplex RS-485 communication. Data+/-  
pins are served for both data transmitting and receiving, depending on the mode selected: either  
Automatic Data Direction Control (ADDC) or By RTS mode.  
Automatic Data Direction Control Mode  
Automatic Data Direction Control scheme is the best solutions for RS-485 applications. The data  
mode selection jumper for the port should be set to Left position, to be able to use Automatic Data  
Direction Control Mode.  
Under this mode, no extra code is required to control the data transferring (data transmitting and  
receiving), which is automatically managed with the intelligent hardware mechanism. That is,  
RS-485 programming in this mode is just as simple as RS-232/RS-422 programming.  
By RTS Mode  
If the data mode selection jumper for the port is set to Right position, By RTS mode is used. The  
port is ready for transmitting data if RTS signal is asserted and ready for receiving data if RTS  
signal is not asserted.  
RTS scheme is a traditional way and suitable for most system, including Windows NT , Windows  
95/98 and DOS, that permits RTS control from application programs. This mode should be  
compatible with most of the already-made RS-485 applications.  
How to transmit and receive data for Windows NT, 95/98 & DOS  
We recommend you to configure Industio CP-114 Series ports as follows in order to acquire precise  
timing control in RS-485 2-wire transmission.  
Industio CP-114 User's Manual 4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
There are 2 solutions to control RS-485 2-wire transmission.  
Solution 1  
The following model is common in RS-485 2-wire transmission.  
sio_SetWriteTimeouts(port, 0); /* Set sio_write() into block mode if for Windows NT  
and Windows 95/98 */  
sio_RTS(port, 1);  
/* Turn on RTS signal. The RS-485 port is ready for  
transmitting data. */  
sio_write(port, buff, 10);  
sio_RTS(port, 0);  
/* Write 10 byte characters in "buff". The function  
blocks until last character transmitted */  
/* Turn off RTS signal. The RS-485 port is ready for  
receiving data. */  
sio_read(port, buff, 10);  
/* Read 10 bytes */  
Solution 2  
There is a dedicated RS-485 function in PComm or API-232 library. It integrates the above  
functions of solution 1 regarding sending data as one.  
sio_putb_x(port, buff, tick ); /* 1. Turn on RTS and ready for transmitting data.  
2. Send data.  
3. Wait for tick time.  
4. Turn off RTS and ready for receiving data. */  
For more information on these functions, please refer to PComm library on-line Help file for  
Windows NT and Windows 95/98 or API-232.txt file for DOS, respectively.  
4-8 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
5
Connection Cable and Cable Wiring  
In serial data communications, the term DTE is for Data Terminal Equipment, like PC COM1/2,  
serial printers and terminals. The term DCE is for Data Communication Equipment, like modems.  
RS-232 Cable Wiring  
The followings are pin assignments for the DB9 RS-232 connector for Port 1 and Port 2 of Industio  
CP-114 Series.  
CP-114 Series  
(DTE, DB9 Male)  
1
2
3
4
5
6
7
8
DCD  
RxD  
TxD  
DTR  
GND  
DSR  
RTS  
CTS  
Industio CP-114 User's Manual 5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Type 1: To connect the Industio CP-114 Series to a DTE device.  
PC COM2 port, Serial Printer,  
Terminal, or any DTE Device  
CP-114  
CP-114  
DB9 Male  
DTE Device  
DB25 Male  
RxD  
TxD  
CTS  
RTS  
DTR  
DSR  
GND  
DCD  
2
3
8
7
4
6
5
1
2
3
4
5
6
20  
7
TxD  
RxD  
RTS  
CTS  
DSR  
DTR  
GND  
DCD  
8
PC COM2 port, Serial Printer,  
Terminal, or any DTE device  
CP-114  
CP-114  
DB9 Male  
DTE Device  
DB9 Male  
TxD  
RxD  
RTS  
CTS  
DSR  
DTR  
GND  
DCD  
3
2
7
8
6
4
5
1
2
3
8
7
4
6
5
1
RxD  
TxD  
CTS  
RTS  
DTR  
DSR  
GND  
DCD  
5-2 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connection Cable and Cable Wiring  
Type 2: To connect Industio CP-114 Series to a DCE device.  
Modem  
or any DCE Device  
CP-114  
CP-114  
DB9 Male  
DCE Device  
DB25 Female  
RxD  
TxD  
CTS  
RTS  
DTR  
DSR  
GND  
DCD  
2
3
8
7
4
6
5
1
2
3
4
5
6
20  
7
RxD  
TxD  
CTS  
RTS  
DTR  
DSR  
GND  
DCD  
8
Type 3: To connect Industio CP-114 Series to a DTE with 3-pin wiring.  
If the [Hardware flow control] feature is set to “ON”, you must loop back (or short) the  
RTS with CTS and the DSR with DTR, DCD on the MOXA site.  
If [Hardware flow control] feature is set to “OFF”, you could just leave RTS, CTS,  
DSR, DTR, DCD open, ignoring the connection indicated in dash-lines.  
PC COM2 port, Serial Printer,  
Terminal, or any DTE Device  
CP-114  
CP-114  
DB9 Male  
DTE Device  
DB25 Male  
TxD  
RxD  
GND  
RTS  
CTS  
DTR  
DSR  
DCD  
3
2
5
7
8
4
6
1
2
3
7
4
5
20  
6
TxD  
RxD  
GND  
RTS  
CTS  
DTR  
DSR  
DCD  
8
PC COM2 port, Serial Printer,  
Terminal, or any DTE device  
CP-114  
CP-114  
DB9 Male  
DTE Device  
DB9 Male  
TxD  
RxD  
GND  
RTS  
CTS  
DSR  
DTR  
DCD  
3
2
5
7
8
6
4
1
3
2
5
7
8
6
4
1
TxD  
RxD  
GND  
RTS  
CTS  
DSR  
DTR  
DCD  
Industio CP-114 User's Manual 5-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-422 Cable Wiring  
The RS-422 standard uses a balanced voltage digital interface to allow 9600 bps communication  
over cables of up to 400 ft (1.2 km) in length. Ten receivers can be connected to any one driver for  
broadcasting systems.  
RS-422 pin outs for Industio CP-114 Series:  
CP-114  
1
2
3
4
5
6
7
8
9
TxD-(A)  
TxD+(B)  
RxD+(B)  
RxD-(A)  
GND  
RTS-(A)  
RTS+(B)  
CTS+(B)  
CTS-(A)  
1 TxD-(A)  
2 TxD+(B)  
3 RxD+(B)  
4 RxD-(A)  
5 GND  
RTS-(A)  
6
RTS+(B) 7  
CTS+(B) 8  
CTS-(A)  
9
RS-422 Point-to-point  
RS-422 Broadcasting  
CP-114  
RS-422 Device  
CP-114  
RS-422 Device 1  
2
1
3
4
5
TxD+(B)  
RxD+(B)  
RxD-(A)  
TxD+(B)  
TxD-(A)  
GND  
2
3
1
4
5
TxD+(B)  
RxD+(B)  
TxD-(A)  
RxD-(A)  
GND  
RxD+(B)  
TxD+(B)  
RxD-(A)  
TxD-(A)  
GND  
TxD-(A)  
RxD+(B)  
RxD-(A)  
GND  
RS-422 Device N  
RxD+(B)  
TxD+(B)  
RxD-(A)  
TxD-(A)  
GND  
RS-422 with Handshaking  
CP-114  
RS-422 Device  
RxD+(B)  
RxD-(A)  
TxD+(B)  
TxD-(A)  
GND  
CTS+(B)  
CTS-(A)  
RTS+(B)  
RTS-(A)  
2
1
3
4
5
7
6
8
9
TxD+(B)  
TxD-(A)  
RxD+(B)  
RxD-(A)  
GND  
RTS+(B)  
RTS-(A)  
CTS+(B)  
CTS-(A)  
5-4 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connection Cable and Cable Wiring  
RS-485 Cable Wiring  
The RS-485 standard is an enhanced version of the RS-422 balanced line standard. It allows multiple  
drivers and receivers in a multidrop systems. As many as 32 drivers and 32 receivers can be put on  
any multidrop system.  
The Industio CP-114 Series supports only 2-wire half-duplex RS-485 communication. Data+/-  
pins are served for both data transmitting and receiving, depending on the RTS signal.  
RS-485 pin outs for the Industio CP-114 Series:  
CP-114  
1
2
5
Data-(A)  
Data+(B)  
GND  
1 Data-(A)  
2 Data+(B)  
5 GND  
Multidrop RS-485 Half-duplex  
CP-114  
Master  
RS-485 Device 1  
Slave  
2
1
5
Data+  
Data-  
GND  
Data+  
Data-  
GND  
RS-485 Device N  
Slave  
Data+  
Data-  
GND  
See the section “RS-485 Programming” of the chapter “Serial Programming Tools” for more  
RS-485 programming details.  
Industio CP-114 User's Manual 5-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Impedance Matching and Termination Resistors  
For RS-422/485 serial communications, when an electrical signal travels through two different  
resistance junctions in a transmission line, the impedance mismatch will sometimes cause signal  
reflection. Signal reflection causes signal distortion, which in turn will contribute communication  
errors. The solution to this problem is to establish the same impedance at the line ends as in the line  
itself by terminating them with resistors.  
Industio CP-114 Series already installs the resistors on board for your convenience, indicated as  
follows. The value of the termination resistor should equal the characteristic impedance of the  
transmission line. Resistors should be added near the receiving side. Note: Stands for termination  
resistor near the receiving side.  
CP-114 Series  
RS-422/485 Device  
2
1
3
4
7
6
8
9
TxD+(B)  
TxD-(A)  
RxD+(B)  
RxD-(A)  
RTS+(B)  
RTS-(A)  
CTS+(B)  
CTS-(A)  
RxD+(B)  
RxD-(A)  
TxD+(B)  
TxD-(A)  
CTS+(B)  
CTS-(A)  
RTS+(B)  
RTS-(A)  
JP5:Interface selection Jumper for Port 1  
JP6:Interface selection Jumper for Port 2  
SW2  
SW1  
RS-422  
RS-232  
SW1: RS-422/RS-485 Selection Switch for Port 1/2/3/4  
SW2: Data Mode Switch for Port 1/2/3/4  
AUTO  
RS-485  
RS-485  
JP5  
ON  
O
N
1
2
3
4
1
2
3
4
RS-422  
RS-485  
JP6  
RS-232  
By RTS  
RS-422  
JP1  
JP2  
JP4  
JP3  
JP1/2/4/3:Termination Resistor Jumper for Port 1/2/4/3  
Industio CP-114 Series Board  
5-6 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connection Cable and Cable Wiring  
DB37 Connector  
The following lists the pin assignments of the Industio CP-114 Series DB37 connector on the  
bracket. With this information, you may fabricate any type of fan-out cables, such as DB37 to DB9  
x 4 or DB37 to DB25 x 4.  
For RS-232 Mode  
Pin no.  
Signal  
Pin no.  
Signal  
29  
11  
12  
13  
14  
15  
16  
36  
37  
RI2  
19  
30  
31  
32  
33  
34  
17  
18  
TxD1  
DTR2  
DSR2  
RTS2  
TxD2  
DCD1  
DSR1  
RTS1  
DCD2  
GND  
CTS2  
RxD2  
RI1  
DTR1  
CTS1  
RxD1  
Note: Make shield grounded to connector.  
For RS-422 Mode  
Pin no. Signal  
Pin no.  
Signal  
1
2
3
4
5
6
7
8
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
CTS2-(A)  
RxD2-(A)  
RTS2-(A)  
RTS2+(B)  
RxD2+(B)  
TxD3-(A)  
GND/VEE3  
CTS3+(B)  
TxD3+(B)  
CTS1-(A)  
RxD1-(A)  
RTS1-(A)  
RTS1+(B)  
RxD1+(B)  
TxD0-(A)  
GND/VEE0  
CTS0+(B)  
TxD0+(B)  
TxD2-(A)  
GND/VEE2  
CTS2+(B)  
TxD2+(B)  
CTS3-(A)  
RxD3-(A)  
RTS3-(A)  
RTS3+(B)  
RxD3+(B)  
TxD1-(A)  
GND/VEE1  
CTS1+(B)  
TxD1+(B)  
CTS0-(A)  
RxD0-(A)  
RTS0-(A)  
RTS0+(B)  
RxD0+(B)  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
Note: Make shield grounded to connector.  
For RS-485 Mode  
Pin no.  
Signal  
Pin no.  
Signal  
2
3
5
11  
12  
14  
Data2-(A)  
GND/VEE2  
Data2+(B)  
Data1-(A)  
GND/VEE1  
Data1+(B)  
25  
26  
28  
34  
35  
37  
Data3-(A)  
GND/VEE3  
Data3+(B)  
Data0-(A)  
GND/VEE0  
Data0+(B)  
Note: Make shield grounded to connector.  
Industio CP-114 User's Manual 5-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
6
Troubleshooting  
Common Industio CP-114 Series problems and possible solutions are listed below. If you still have  
problems, contact your dealer or Moxa for help. Or use the “Problem Report Form” at the end of  
this manual to report problems to your dealer at once for faster technical support.  
General Troubleshooting  
1. The MOXA driver, while installing the driver, cannot detect the MOXA PCI board.  
Hardware causes and solutions:  
a. The board is not installed or missing (absent). Please install it.  
b. The board is not properly plugged in the system. If that is the case, re-install the board and make  
sure that it fits well in a 32-bit PCI slot this time. Sometimes the slot for plugging the board is bad.  
In this case, try other slots until you find a good one.  
c. Your motherboard does not have a vacant IRQ for the CP-114 Series. Please enter BIOS and  
make sure there are available IRQ in PCI/PnP settings.  
2. The MOXA board and driver are activated but cannot transfer (transmitting/receiving)  
data.  
Hardware Causes and Solutions:  
a. Check for wrong cable wiring. Refer to the “Connection Cable and Cable Wiring” chapter for  
precise pinouts of the connector type you are using.  
b. The cables or the boards are defective. You may use other ports, cables or boards to verify. In  
addition, the PComm “Diagnostic” utility for Windows NT and Windows 95/98 is good for testing  
MOXA boards and port conditions. If Diagnostic reports error, replace the faulty components.  
Software Causes and Solutions:  
a. For RS-422 mode, Industio CP-114 Series checks the line status (CTS) before it sends data out if  
the RTS/CTS flow control feature is set to “Enable” in the configuration or application program.  
Please refer to the “Connection Cable and Cable Wiring” chapter for proper wiring.  
b. Perhaps the application controlling the board is not correctly written according to the  
corresponding API of the operating system. To verify, please run an existing and known good  
application or the provided utilities by Moxa. For example, under Windows NT and Windows  
95/98, Pcomm “Terminal emulator” or “HyperTerminal” utilities are good for testing the COM  
ports.  
Windows NT  
This section is specific for troubleshooting under Windows NT. For general problems and solutions,  
please see the previous section, “General Troubleshooting”.  
1. After the system reboots, the error message “Another driver in the system, which did not  
report its resources, has already claimed the interrupt used by xxx.” appears in the Event  
Log.  
Industio CP-114 User's Manual 6-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
This indicates that the MOXA board is found, but the IRQ is conflicting with another adapter.  
Please make sure there is no conflict with other adapter’s IRQ. Check the PCI BIOS IRQ settings  
first. Make sure that an IRQ is available.  
2. After the system reboots, the error message “Cannot find any configured MOXA  
Smartio/Industio PCI Series board!” appears in the Event Log.  
Please make sure the PCI board is seated firmly in the expansion slot.  
3. The COM number of the Industio CP-114, with device number xx, conflicts with others.  
The COM numbers of different boards happen to be the same. Try to change the COM number  
mappings.  
4. Windows NT system panic (blue screen).  
The possible reason is an IRQ or I/O address conflict with other ISA Bus adapters, like LAN and  
SCSI boards, or the system BIOS. Please refer to the corresponding problem in the previous  
section, “General Troubleshooting”, for solutions.  
Windows 95/98  
This section is specific for troubleshooting under Windows 95/98. For general problems and  
solutions, please see the previous section, “General Troubleshooting”.  
1. The system fails to find the Industio CP-114 board!  
- The board(s) is not plugged properly.  
- The slot for plugging the board is defective.  
In this case, please try other slots until you find a good one.  
- The board might be defective.  
2. After the system reboots, the error message “CP-114 (BusNo=x, DevNo=x, Port1=COMx)  
interrupt number is invalid!” appears.  
This indicates that the MOXA board is found, but the IRQ is conflicting with other adapter.  
Make sure MOXA board’s IRQ is not conflicting with other adapter’s. Check the PCI BIOS IRQ  
settings and select an available IRQ for MOXA boards.  
6-2 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
A
A
Technical Reference  
Specification  
"
"
"
"
"
"
"
"
Bus interface:  
Number of ports:  
I/O address:  
IRQ:  
Data bits:  
Stop bits:  
Parity:  
UART:  
Speed (bps):  
Connectors:  
32-bit PCI (Spec 2.1)  
2 (RS-232 or RS-422/485), 2 (RS-422/485)  
Assigned by BIOS  
Assigned by BIOS  
5, 6, 7, 8  
1, 1.5, 2  
None, even, odd, space, mark  
16C550C or compatible×4, each with 16byte Tx/Rx FIFO  
50 ~ 921.6K  
"
"
DB9 (male)×4  
"
Data signals:  
RS-232TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND  
RS-422TxD(B)+/(A)-, RxD(B)+/(A)-, RTS(B)+/(A)-, CTS(B)+/(A)-,  
GND  
RS-485Data(B)+/(A)-, GND  
"
"
"
Isolation protection: Max. 2000V (CP-114I, CP-114IS)  
Surge protection:  
Operating temp:  
ESD 25KV (CP-114S, CP-114IS)  
0 ~ 55 ℃  
"
"
"
Regulation Approval: CE, FCC Class A  
OS supported:  
Windows NT, Windows 95/98, DOS  
Termination resistor: RS-422: 120 Ohm  
RS-485: 120 Ohm, jumper enable/disable  
"
Power requirement:  
Dimensions:  
CP-114: 720mA max. (+5V), 43mA max. (+12V), 31mA max.(-12V)  
CP-114S: 735mA max. (+5V), 44mA max. (+12V), 33mA max.(-12V)  
CP-114I: 1164mA max. (+5V), 35mA max. (+12V), 48mA max.(-12V)  
CP-114IS: 1170mA max. (+5V), 36mA max. (+12V), 49mA max.(-12V)  
"
CP-114/CP-114S: 135 mm×110 mm  
CP-114I/CP-114IS: 160 mm× 120 mm  
PCI  
The 32-bit Industio CP-114 Series board complies with the PCI specifications 2.1. Hardware  
configuration for IRQ and I/O addresses is automatically assigned by the PCI BIOS. Hence, you  
must first plug the board before installing the software driver.  
Unlike ISA slots, different PCI slots in the same PC may have different bus numbers and device  
numbers with respect to the PCI specifications. The same PCI board will have different system  
configurations if switching to a different PCI slot, which may be called slot-sensitive or  
slot-dependent. This may also apply to PCI slots in PC with different motherboard, which may use  
different device number sets. For example, some use 17, 18, 19, and 20 for identifying the  
respective PCI slots but some use 11, 12, 13 and 14.  
Due to the slot-dependency, it is necessary to re-configure the software driver once the board is  
plugged in different PCI slots.  
Up to 4 Industio CP-114 Series boards are allowed in one system. When installing more than one  
board, please remember the order of boards for distinguishing the installed boards.  
UART 16C550C  
Industio CP-114 User's Manual A-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
The UART chip, 16C550C, is an intelligent asynchronous controller capable of supporting one full  
duplex channel that simultaneously transfers data at 921.6 Kbps. To increase the overall data  
throughput, special features such as on-chip FIFO and on-chip hardware flow control are used to  
reduce the number of interrupts to the onboard CPU and to prevent any loss of valuable data.  
A-2 Industio CP-114 User's Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem Report Form  
Industio CP-114 Series  
Customer name:  
Company:  
Tel:  
Fax:  
Email:  
Date:  
1. Moxa Product: CP-114 Series Model : $CP-114 $CP-114I $CP-114S $CP-114IS  
Serial Number: ________________  
2. Moxa Driver Version: ________________  
3. Moxa Hardware Settings: PCI slot number ________________________  
4. Operating System: $ Windows 95  
$
$
$
Windows 98  
Windows NT 4.0  
Others  
$
$
Windows NT 3.51  
DOS  
5. PC Host: Make _________  
Model _________  
Make ______  
6. CPU:  
Speed _____MHz  
Model ______  
7. BIOS:  
Make __________________  
Version _______  
8. PCI IRQ Configuration in BIOS:  
PORT  
I/O  
1
2
3
4
IRQ  
Interface  
(RS-232/422/485)  
RS-485 Data Mode  
(ADDC/RTS)  
9. Problem Description: Please describes the problem as clearly as possible, including the error message you see. We may have to  
follow your description to reproduce the problem.  
$
$
$
Board not found.  
Can transfer data, but lose data.  
Others. Detailed error message description is recommended:  
$
$
Board found, but can’t transfer data.  
Can transfer data, but with garbled data.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Return Procedure  
For product repair, exchange or refund, you must:  
" Provide evidence of original purchase.  
" Fill out the Problem Report Form (PRF) as detailed as possible for shorter product repair time.  
" Obtain a Return Merchandise Authorization (RMA) number from the sales representative or dealer.  
" Carefully pack the product in an anti-static package, and send it, pre-paid, to the dealer. The RMA number should be  
visible on the outside of the package, and include a description of the problem along with the return address and  
telephone number of a technical contact.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Revision History  
Document Edition  
Revision Date  
Revision Details  
3rd  
January 27, 2004  
1. Update the edition of this manual on the  
title page.  
2. p. 5-5:  
Changed RS-422 Broadcasting figure.  
1. Updated Moxa logo.  
2. Corrected errors in Chap. 5.  
4th  
November 8, 2004  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Freezer K 122 Ui 1 User Manual
Oakley MP3 Player THUMP User Manual
Oki Computer Drive 59375102 User Manual
Olympus Computer Drive C P20U User Manual
Omnitron Systems Technology Microphone HM 1000 User Manual
Oreck Vacuum Cleaner UPRO14T User Manual
Oregon Scientific Thermometer RMR382A User Manual
Panasonic Digital Camera DMC FX01 User Manual
Panasonic Laptop CF H1ADBAZW3 User Manual
Parkside Engraver PMGS 12 A1 User Manual