INSTALLATION AND OPERATION MANUAL
TM
Direct-Vent
Gas Fireplace
Installer: Leave This Manual With The Appliance.
Consumer: Retain This Manual For Future Reference.
P/N 775,219M Rev. C, 06/2009
A French manual is available upon request. Order P/N 775,219CF.
Ce manuel d’installation est disponible en francais, simplement
en faire la demande. Numéro de la pièce 775,219CF.
In the Commonwealth of Massachusetts:
Portland
• Installation must be performed by a licensed plumber or gas fitter
• See Table of Contents for location of additional Commonwealth of
Massachusetts requirements
US
Ravelle™ 42 (RAVL42)
Report No.050-S-08c-5
WARNINGS
• Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat
for a while after shutting off the appliance. Severe burns may result.
• Carefully supervise children in the same room as appliance. If small children are present in the home, it is
recommended that this appliance be fitted with a barrier screen kit. See Page 37 for ordering information.
• These appliances may be installed in an aftermarket permanently located, manufactured (mobile) home (USA
only), where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
• Lennox Hearth Products gas-burning appliances are designed for use as a supplemental heater. They are not
intended for continuous use as a primary heat source.
AVERTISSEMENT:Assurez-vousdebiensuivrelesinstruc-
tionsdonnéesdanscettenoticepourréduireauminimum
le risque d’incindie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result causing property damage, personal injury
or death.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
- WHAT TO DO IF YOU SMELL GAS
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindie.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
- L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par
le fournisseur de gaz.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Download from Www.Somanuals.com. All Manuals Search And Download.
Vertical Vent Termination Clearances ........................ 18
Horizontal Terminations......................................... 19
Vertical Terminations............................................ 19
Horizontal Vent Termination Clearances ..................... ꢀ0
Brick Panel and Log Set Installation.................................... ꢀ1
Electrical Connections .................................................... ꢀꢀ
Gas Line Installation ...................................................... ꢀ3
Gas Pressure Requirements.................................... ꢀ3
LP and Natural Gas Supplies................................... ꢀ3
Increasing Efficiency And Hot Air Movement .......................... ꢀ4
Forced Air Heating Installation ......................................ꢀ5-ꢀ8
Operating Instructions ................................................ꢀ9-3ꢀ
Pre-Lighting Checklist........................................... ꢀ9
Lighting Instructions............................................. ꢀ9
Flame Color and Behavior ...................................... 30
Air Shutter Adjustment .......................................... 31
Paint Curing....................................................... 31
Quiet Operation................................................... 31
Blower Operation................................................. 31
Optional Wall Thermostat....................................... 31
Operating Options................................................ 3ꢀ
Millivolt Control System ........................................ 3ꢀ
Maintenance and Servicing ..........................................33-34
Maintenance Checklist .......................................... 33
Vent Pipe Maintenance.......................................... 33
Opening and Removing Door................................... 34
Glass/Door Maintenance........................................ 34
Blower Removal.................................................. 34
Fuel Conversion .................................................. 34
Troubleshooting............................................................ 35
Replacement Parts ........................................................ 36
Accessories.............................................................36-37
Fireplace Labels .......................................................38-39
Product Reference Information .......................................... 40
CONGRATULATIONS!
When you purchased your new gas fireplace, you joined the
ranks of thousands of individuals whose answer to their home
heating needs reflects their concern for aesthetics, efficiency
and our environment. We extend our continued support to help
youachievethemaximumbenefitandenjoymentavailablefrom
your new gas fireplace.
Thank you for selecting a Lennox Hearth Products gas fireplace
as the answer to your home heating needs.
TABLE OF CONTENTS
Cautions and Safety ........................................................ ꢀ
Orifice Size/Altitude Adjustment.......................................... 4
Codes and Approvals....................................................... 5
New York City, New York (MEA) .......................................... 5
Commonwealth of Massachusetts Requirements...................... 5
Pre-Installation............................................................ 6-7
Features ............................................................ 6
Venting.............................................................. 6
Fuel.................................................................. 6
Packaging List..................................................... 6
Specifications...................................................... 6
Preparing your Fireplace for Installation......................... 7
Clearances to Combustibles..................................... 7
Installation............................................................... 8-13
Framing Dimensions ............................................. 8
Fireplace Dimensions ............................................ 9
Raised Installations ............................................. 10
Hearth Extension Considerations.............................. 10
Facing Installation Considerations............................ 11
Face Installation ................................................. 13
Vent Installation .......................................................14-ꢀ0
Application ........................................................ 14
Vent Parts List .................................................... 15
Vent Considerations ............................................. 16
Horizontal Vent Installation..................................... 17
Vertical Vent Installation........................................ 17
Flue Restrictors .................................................. 18
USING THIS MANUAL
Please read and carefully follow all of the instructions found in this
manual. Please pay special attention to the safety instructions provided
in this manual.
PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE
3
Download from Www.Somanuals.com. All Manuals Search And Download.
ORIFICE SIZE/ALTITUDE ADJUSTMENT
THE RAVELLE™ 4ꢀ FIREPLACE
For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice
should be de-rated by 4% for every 1,000 feet to maintain the proper
ratio of gas to air. Improper orifice sizing may result in damage and
unsafe conditions. Changing the orifice should only be done by a quali-
fied service technician. Contact your Lennox Hearth Products dealer for
proper orifice sizes.
•
Must conform with all local, state and national installation codes.
In the absence of local codes, the installation must conform with
National Fuel Gas Code ANSI Z223.1 - latest edition, also known
as NFPA 54 (In Canada, the current CAN/CSA B149.1 installation
code). Refer to the National Fuel Gas Code and local zoning and
code authorities for details on installation requirements.
•
•
Mobile home installations must conform with the Mobile Home
ConstructionandSafetyStandard,Title24CFR,Part3280(inCanada
CAN/CSA Z240 MH), or, when such a standard is not applicable,
the Standard for Mobile Home Installations, ANSI A225.1 - latest
edition.
SMOKE DETECTORS
Since there are always several potential sources of fire in any home, we
recommend installing smoke detectors. If possible, install the smoke
detector in a hallway adjacent to the room (to reduce the possibility of
occasional false activation from the heat produced by the appliance). If
your local code requires a smoke detector be installed within the same
room, you must follow the requirements of your local code. Check with
your local building department for requirements in your area.
Must be vented directly to the outside in accordance with the latest
edition of the National Fuel Gas Code and must never be attached
to a chimney serving a separate solid fuel burning appliance.
•
•
•
Has been certified for use with either natural gas or propane.
Is not for use with solid fuels.
Is approved for sitting rooms and/or bedrooms.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
CODES AND APPROVALS
Certification
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
(Massachusetts Approval #G3-1104-10ꢀ)
These fireplaces are approved for installation in the US state of Mas-
sachusetts if the following additional requirements are met:
Gas appliances must be tested and certified by a nationally recognized
testing and certification laboratory to ANSI (American National Standard
Institute) gas appliance safety standards.
• Install this appliance in accordance with Massachusetts Rules and
Regulations 248 C.M.R. Sec. 5.08 2(a) through 2(e).
This fireplace has been tested and certified by OMNI -Test Laboratories to
ANSIZ21.88/CSA2.33StandardforVentedGasFireplaceHeaterandCGA
2.17-M91andUL307BGasBurningHeatingAppliancesforManufactured
(Mobile) Homes in both USA and Canada.
• Installation and repair must be done by a plumber or gas fitter licensed
in the Commonwealth of Massachusetts.
• The flexible gas line connector used shall not exceed 36 inches (92
centimeters) in length.
It has met all necessary ANSI Standards and is fully certified for installa-
tion in any community. If there are any questions or if you need further
substantiation either write to or call your Lennox Hearth Products dealer.
If you have further questions, please contact Lennox Hearth Products.
• The individual manual shut-off must be a T-handle type valve.
Massachusetts Horizontal Vent Requirements
Checkalllocalbuildingandsafetycodesbeforeinstallation.Theinstallation
instructions and appropriate code requirements must be followed exactly
and without compromise. In the absence of local codes the following
standards and codes must be followed.
IntheCommonwealthofMassachusetts,horizontalterminationsinstalled
less than seven (7) feet above the finished grade must comply with the
following additional requirements:
• A hard wired carbon monoxide detector with an alarm and battery
back-up must be installed on the floor level where the gas fireplace
is installed. The carbon monoxide detector must comply with NFPA
720, be ANSI/UL 2034 listed and be ISA certified.
NEW YORK CITY, NEW YORK (MEA)
(NYC MEA Approval #138-07-E)
• A metal or plastic identification plate must be permanently mounted to
the exterior of the building at a minimum height of eight (8) feet above
grade and be directly in line with the horizontal termination. The sign
must read, in print size no less than one-half (1/2) inch in size, GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.
Installation of these fireplaces are approved for installation in New York
City in the US state of New York.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Fuel
PRE-INSTALLATION
This fireplace comes from the factory equipped to burn natural gas at a
specified elevation. The fireplace can be converted to burn LP gas (liquid
propane) by changing the cassette (valve and pilot assembly) or installing a
conversionkit. OnlyLennoxHearthProductsconversionkitscanbeusedto
convert from NG to LP or LP to NG. Contact your Lennox Hearth Products
dealer for details.
Features
Installation Options
Residential
Specifications
Vented vertical and horizontal
Manufactured (mobile) home
Natural gas (NG) or propane (LP)
Bedrooms
Optional wall-mounted or remote thermostat
Ductable for greater heat distribution
Fireplace weight: 250 lbs
Pipe:Type - direct-vent
Recommended manufacturer*
Security™ Secure Vent™*
Diameter - 6-5/8”x 4” for vertical terminations
Diameter - 8”x 5” for horizontal terminations
Venting
Packaging List
This fireplace can be vented with Security™ Secure Vent™ pipe*. Coaxial
pipe diameters are 6-5/8” outer and 4” inner. The combustion air for this
fireplace is drawn from outside the house through the outer DV (direct
vent) pipe. Room air is not required for combustion.
The Ravelle™ 4ꢀ gas fireplace comes with the following parts:
1 Fireplace Body with Burner Cassette
1 Log Set
1 Bag of Ember Material
1 Installation and Operation Manual
When planning your installation, select the correct length of vent pipe
for your particular requirements. Determine the minimum clearance to
combustibles from the rear of the unit to the wall. It is also important
to note the thickness of the wall. Before cutting the vent hole through
the wall make sure that ALL vent and termination clearances (see Pages
18-20) will be met.
Decorative Faces - One Required
Arch Inset
Classic Inset
Screen
Foundry™
Electrical
Brick Liners - One Required
Ductability (optional)
The standard fan motor requires 120 Volts AC for operation. The fireplace
is not dependent on the fan or an outside electrical supply to operate.
Standard Brick
Red Brick
Forced Air Duct Kit
Whole Home Comfort
System
Architectural Stone
Millivolt Valve
Note: See Pages 36 and 37 for ordering information.
This fireplace is operated with a millivolt valve and therefore burns even
during a power outage.
* Other approved chimney brand is Simpson Dura-Vent DV-GS.
Model Ravelle 42
RATINGS
NATURAL GAS
4ꢀ,000 / ꢀ9,500
3.5 / 1.7
5
LP GAS
36,000 / ꢀ5,000
10 / 5.1
11
Max/Min Input BTUh 0-ꢀ,000 Feet (0-610 M)u
Manifold Pressure (IN. WC)
Min. Inlet Pressure (IN. WC)
Maximum heat output BTUs/hour-steady state
34,860
ꢀ9,880
P4 Efficiency
50.43%
#30
53.47%
#49
Orifice (DMS) 0-ꢀ,000 Feet (0-610 M)
u
u
v
w
Unit factory equipped for 0-ꢀ000 FT/0-610 M, In Canada 0-4500 FT/0-1370 M
The Steady State Efficiency numbers based on maximum vent configuration.
Tested to CSA P.4.1-0ꢀ “Testing Method for Measuring Annual Fireplace Efficiency.
Electrical Rating: 1ꢀ0 VAC, 60 HZ, Less Than ꢀ Amps
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Preparing Your Ravelle™ 4ꢀ Fireplace For Installation
Dimensions
Read all instructions before beginning your installation. If instructions
have not been read carefully, your installation could void your warranty
and may create a serious fire, health, or other safety hazard.
ꢀ9-3/4”
(756mm)
w
The Lennox Hearth Products warranty will be voided if one of the fol-
lowing occurs:
• Installation of any damaged fireplace or vent system compo-
nent.
• Unauthorized modification of the direct vent system.
• Installation other than as instructed by Lennox Hearth Products,
Security™, or Simpson Dura-Vent.
• Installation of any fireplace or vent system component not manu-
factured or approved by Lennox Hearth Products, Security™ or
Simpson Dura-Vent.
38-1/4”
(97ꢀmm)
47-3/4”
(1ꢀ13mm)
35-1/ꢀ”
(90ꢀmm)
u
41”
(1041mm)
v
When planning the installation for your Ravelle 42 gas fireplace, it’s
necessary to consider the following:
• Where the unit is to be installed
• The vent system configuration to be used
• Gas supply (NG or LP)
43”
(109ꢀmm)
ꢀ0-3/4”
(5ꢀ7mm)
w
Figure 1
• Electrical wiring
• Framing and finishing
• Optional accessories
u The center of the access hole for the gas piping is located at the
left side of the fireplace 6-7/8” back from the front edge and ꢀ-1/8”
up from the base of the unit.
v The electrical access is located at the right lower rear of the fire-
Clearances to Combustibles
place.
w These dimensions include the 3/4” stand-offs.
Minimum clearances include any projections such as shelves, window
sills,mantels,spacers/standoffsorsurfacestocombustibleconstruction
etc. above the appliance. Paint or lacquer used to finish the mantel
must be heat resistant in order to avoid discoloration.
Minimum clearances to combustible materials in inches:
Installations in the shaded
area require five inches
clearance on top of pipe.
Front corners to enclosure (from stand-offs)
Rear corners to enclosure (from stand-offs)
Top to header (from stand-offs)
0 (0mm)
0 (0mm)
0 (0mm)
0 (0mm)
Bottom of unit to floor
Edge of door glass to side wall and side trim
Back to enclosure (from stand-offs)
7-1/2 (191mm)
0 (0mm)
Mantel: The drawing at the lower right shows the minimum distances
from the base of the fireplace to combustible mantel and facing material.
Combustible materials may be placed above and within the shaded areas.
If your fireplace has an arched face, the combustible mantel facing mate-
rial may curve with the arch of the face as long as a minimum distance
of 10” is maintained between the top of the face and the combustible
facing material.
Mantel and Facing Material (side view)
1ꢀ”
(305mm)
ꢀ”
(51mm)
1-1/4”
(3ꢀmm)
5-1/4”
(133mm)
Hearth Protection: Hearth protection in front of the Ravelle™ 42 gas
fireplace is not required. However, hearth protection is recommended
and will enhance the appearance of the fireplace.
7-1/ꢀ”
(191mm)
49-5/8”
(1ꢀ61mm)
Pipe Clearances: All installations using a vertical termination cap
must maintain 1” (25mm) clearance between the direct vent pipe and
combustibles. For horizontal terminations, when the top of the horizontal
run of pipe is less than 8 feet (2.4 M) above the base of the fireplace, 1”
(25mm) clearance on the sides and bottom and 5” (127 mm) on the top
of the pipe is required. For those horizontal runs at or above 8 feet, 1”
(25 mm) is required on the sides and bottom and 2” (51 mm) on the top
of the pipe. See Page 19 for allowable pipe configurations.
Fireplace side view
47-5/8”
(drawing not to scale)
(1ꢀ10mm)
41-5/8”
(1057mm)
Figure 2
Base of Fireplace
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
A 6” (152 mm) header may need to be notched to accommodate vertical
vent pipe. If the fireplace is going to be horizontally vented directly out
the back, do not place a stud in line with the wall thimble. If a hearth
extension greater than 1” (25 mm) thick is going to be used, the fire-
place and the header must be raised accordingly. See Hearth Extension
Considerations for further details.
INSTALLATION
Framing Dimensions
Thedimensionsgivenonthispageareminimumframingdistancesneces-
sary to maintain safe clearances between the Ravelle™ 42 gas fireplace
and combustible materials.
Insulation: The exterior walls adjacent to the fireplace should be
insulated like the rest of the house, but insulation should not be placed
around the fireplace or vent pipe.
uIf the unit is to be vented horizontally with a 90º elbow right off the
top of the fireplace and directly through an exterior wall, then a hole
10-3/4” (273 mm) square with a center line 42-1/4” (1073 mm)
above the base of the fireplace will accommodate the wall thimble
and direct vent pipe.
Corner Installations: The dimensions on this page are minimum and
show the stand-offs on the rear corners of the fireplace up against the
corner walls.
vThe gas line should be routed to the left side of the unit. The access
hole in the fireplace for the gas line is 6-7/8” (175 mm) back from
the front edge and 2-1/8” (54 mm) up from the base of the unit. If
the gas line enters the unit from the right side the piping will need to
be disconnected to remove the fan.
u
C/L
If a wall-mounted on/off switch or thermostat is to be used, these
wires should be routed to the left front of the unit for access to the
fireplace. The wire should be fed through the gas line hole, along the
gas line, to the valve.
v
48”
(1ꢀ19mm)
44-1/ꢀ”
(1130mm)
wThe electrical power supply wiring should be routed to the right rear
of the unit.
Note: The fireplace may be placed directly on wood or non-combustible
flooring, but not on vinyl floor covering or carpet.
ꢀ1”
Framing Suggestions: The framing header above the front of the
fireplace should be as narrow front to back as allowable to give maximum
clearance to the direct vent pipe (i.e. don’t use a 6” (152 mm) thick header
when a 4” (102 mm) thick one is allowed).
(533mm)
w
44-1/ꢀ”
(1130mm)
Figure 3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Fireplace Dimensions
Inches (millimeters)
18-9/16
(471)
29-3/4
(756)
51-1/4
(1302)
Corner Installation
Framing Details
10-3/4
(273)
20-3/4
(527)
38-1/4
(972)
43
(1092)
14
(356)
44-1/2
(1130)
72-1/2
(1842)
5
3-1/2
(89)
(127)
2
(51)
47-3/4
(1213)
41
(1041)
34
(864)
35-1/2
(902)
30
(762)
18-3/16
ELECTRICAL
INLET
30
(762)
(462)
2-1/4
(57)
6-7/8
(175)
GAS INLET
3-1/2
(89)
32-5/16
(821)
6-1/4
(159)
9-1/2
(241)
Figure 4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Raised Installations
Hearth Extension Considerations
The fireplace may be raised by building a platform of sufficient strength to
support the fireplace and pipe. When building a raised hearth extension,
please see the note below regarding height of the fireplace in relation to
the thickness of the hearth extension material.
A hearth extension in front of the fireplace is not required; however, to
enhance the appearance of the Ravelle™ 42 gas fireplace, one is recom-
mended. Note: There is a 1” (25 mm) space between the base of the
fireplace and the bottom of the decorative fireplace face. This space
will allow a 7/8” (22 mm) thick hearth extension (including backer board
if desired). Should a hearth extension thicker than 7/8” (22 mm) be
desired, the height of the fireplace must be raised the thickness of that
hearth extension less the 7/8” (22 mm). For example, if a 2-7/8” (73 mm)
thick cultured stone is to be placed on the floor to serve as the hearth
extension, then the fireplace must be raised 2” (51 mm) (possibly using
1/2” (13 mm) plywood over 2 x 4’s laid flat) to accommodate the 2-7/8”
(73 mm) stone. It is important to note that if the fireplace is raised then
it is necessary to raise the height of the header above the stand-offs
an equal amount. If you wish to install your fireplace without a hearth
extension you must remember to set your finished flooring height 1” (25
mm) higher than the bottom base of the fireplace or install the fireplace
1” (25mm) lower than the finished flooring materials for that room. This
will assure that no gap will exist between the room’s flooring and your
new fireplace decorative face after it is installed.
Raised Platform
for Hearth Extension
f
and Fireplace
Figure 5
Fireplace
Face
BBaassee ooffFiFreirpelapcleace
Nailing
Raised
Niling
Plate
Platform
One Inch Space
Figure 7
Figure 6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
The screws should be driven through the cement board into the outer
metal skin of the fireplace. The sheetrock (drywall) is then butted up
to the cement board. The sheetrock above the fireplace should also be
fastened to the fireplace by driving screws into the outer metal skin of
the fireplace.
Facing Installation Considerations
Non-combustible cement board (such as Wonderboard, Durock, or Har-
dybacker) must extend 10” (254 mm) above the 1” (25 mm) top reveal
and a minimum of 3” (76 mm) from each side reveal (see Figure 8). This
cement board may be 1/4” (6.3 mm) thick or greater, but would normally
be the thickness of the drywall - for example 1/2” (13 mm). The cement
board may be fastened by drywall screws.
Facing Less Than 1” Thick: If the combined thickness of the facing
material (eg. 3/8” [9.5 mm] thick ceramic tile and 1/2” [13 mm] thick
cement board) is less than 1” (25mm), then the tile can be placed behind
the fireplace face (see below).
Sheetrock
3/8” (9.5mm) Tile and 1/ꢀ” (1ꢀ.7mm) Cement Board
38” Tie and 1/2” emen
Behind Fireplace Face
10” (ꢀ54mm)
Minimum
Cement Board
C
(ꢀ5mm)
1” Reveal
3” (76mm)
Minimum
Sheetrock
Cement Board - Minimum
of 3” (76mm) Wide
Figure 8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Facing Greater Than 1” (ꢀ5mm) Thick:
Traditional Face
41”
If the combined thickness of the facing material (eg. brick or cultured
stone) and concrete board is greater than 1”, then the facing material
must be placed around the face. A template (Arch #75098, Foundry™
#75035 and Classic [Louver] #75101) should be used while installing
the facing material. Templates for the various faces may be purchased
from your Lennox Hearth Products dealer or a template may be made of
plywood using the dimensions listed on this page. If you choose to make
a template, 1/8” (3mm) must be added to each side and top dimension
to provide sufficient clearance so the face may be removed for access to
the firebox. Since the bottom of the fireplace face is 1” above the base
of the fireplace, 1” (25mm) must be added to the height of the template
if the template is to rest on the floor or platform on which the fireplace
is placed. It is extremely IMPORTANT that the template be centered left
to right on the glass door of the fireplace.
(1041mm)
30-5/8”
(778mm)
Figure 12
Adjustment prior to arched face installation:
The corners of the 1” (25mm) reveal around the fireplace opening need
to be adjusted prior to installing an arched face (see Figures 13 and
14). Remove screws A and loosen screw B. Rotate the corner downward
bending the metal at pivot point C until the holes from which screws A
were removed line up with the lower set of holes. Reinstall screws A and
tighten screw B. When finished, the corners should look like the corner
shown in Figure 15.
Template
Rn
Reveal Corner
Figure 13
Platform to raise fireplace to accommodate a
hearth extension greater than 1” in thickness.
A
Figure 9
B
B
The fireplace face dimensions are:
C
Expanded View of
Reveal Corner
Arch Face
Figure 14
A
A
30-5/8”
ꢀ6-3/8”
(778mm)
(670mm)
Reveal Corner Adjusted
for Arch Face
41”
(1041mm)
51-1/ꢀ” R
(1308mm)
Figure 10
Figure 15
1ꢀ
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Bracket C in the diagram below is installed on the face during the face
assembly (see instructions included with face). The captive screws D
on this bracket should be screwed into captive nuts E on the fireplace.
A phillips head screwdriver inserted through the vent holes in the face
can be used to complete this task. Align the face for plumb and level
and then tighten all four screws.
Face Installation
A number of different faces are available for the Ravelle™ 42 gas fire-
place, however, all the faces are installed in a similar manner. A total of
four screws (two upper and two lower) attach the face to the fireplace.
To install a face:
1. Locatethetwoscrewsfoundinthehardwarebagshippedwiththeface.
Position the face (with the lower door open) in front of the fireplace.
Install the two screws, A in the diagram below, through the holes in
the lower door hinge bracket and screw them into the captive nut on
tab B located on the fireplace. Do not fully tighten these screws yet.
CAUTION: Any masonry that has been cleaned with an acid
wash must be properly neutralized before installing the fire-
place face. The acid wash will tarnish the face. Consult your
masonry installer.
B
A
A
nd
Expanded View
E
D
C
Figure 16
Expanded View
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Vent Parts List
VENT INSTALLATION
Application:
Direct vent pipe Security™ Secure Vent™* may be used with the Ravelle
42 gas fireplace. Please see the lists below to verify the components avail-
able from each direct vent pipe manufacturer. Snorkel terminations are
available for applications which may require vertical rise on the building
exterior. The components listed below come in a galvanized finish. Most
of the components are also available in a painted black finish. Add a “B”
to the end of the part number when ordering if a black part is desired.
The Ravelle™ 42 gas fireplace, has been tested and listed as a direct
vent heater system by OMNI-Test Laboratories, Portland, Oregon. and
is recommended for use with Security™ Secure Vent™ pipe.
IMPORTANT:
Security™ Secure Vent 6-5/8”x 4” Pipe
• Read all instructions carefully before starting the installation.
Failure to follow these instructions may create a fire or other
safety hazard and will void the warranty. Be sure to check for
specific clearances to combustible requirements on Page 7.
Do not extend the venting system vertically or horizontally in
excess of the distance prescribed on Page 19. Consult your
local building codes before beginning the installation.
• Always maintain the proper air spaces (see Page 7) between
theventpipeandnearbycombustiblestopreventafirehazard.
Do not fill air spaces with insulation. Be sure to check the
ventterminationclearancerequirementsfromdecks,windows,
soffits, gas regulators, air supply inlets and public walkways,
as specified in these installation instructions on Page 20 and
local building codes.
• Thisgasapplianceandventsystemmustbeventeddirectlyto
theoutsideofthebuildingandneverbeattachedtoachimney
serving a separate solid fuel or gas-burning appliance. Each
directventgasappliancemustuseitsownseparateventsystem.
Common vent systems are prohibited.
• The Ravelle 42 gas fireplace is recommended for use
with Security Secure Vent pipe. The appliances and vent
manufacturerswarrantieswillbevoidedandseriousfire,health,
or other safety hazards may result from any of the following
actions:
Part Number
SV4L6
Description
6” Pipe Length
SV4L12
SV4L24
SV4L36
SV4L48
SV4LA
SV4LA12
SV4FA
12” Pipe Length
24” Pipe Length
36” Pipe Length
48” Pipe Length
6” Pipe, Adjustable
12” Pipe, Adjustable
Flashing, 1/12 to 176/12 Roof Pitch
Flashing, 8/12 to 12/12 Roof Pitch
Wall Radiation Shield
45° Elbow
90° Elbow
Vinyl Shield Protector
Storm Collar
Vertical Termination Cap
Firestop
Horizontal Termination Cap
Snorkel Termination (36”) Cap
Snorkel Termination (14”) Cap
Wall Band
SV4FB
SV4RSM
SV4E46
SV4E90
SV4VS
SV4FC
SV4CGV
SV4BF
SV4CHC
SV4STC36
SV4STC14
SV4BM
Simpson DuraVent 6-5/8”x 4” GS Pipe
Part Number
908
907
906
904
903
902
911
912
Description
6” Pipe Length
9” Pipe Length
12” Pipe Length
24” Pipe Length
36” Pipe Length
48” Pipe Length
11” to 14-5/8” Pipe, Adjustable
12” to 17” Pipe, Adjustable
17” to 24” Pipe, Adjustable
Wall Thimble
• Installation of any damaged direct vent component.
• Unauthorized modification of the direct vent system.
• Installation of any vent component part not approved or
manufactured by the approved vent manufacturer.
• Installation other than as instructed by Lennox Hearth
Products and vent manufacturers instructions.
917
942
943
943S
945
Flashing, 0/12 to 6/12 Roof Pitch
Flashing, 7/12 to 12/12 Roof Pitch
45° Elbow
950
953
Vinyl Siding Standoff
Storm Collar
963
980
981
982
984
988
Ceiling Firestop
Vertical Termination
Snorkel Termination (36”)
Snorkel Termination (14”)
Horizontal Square Termination (High Wind)
Wall Strap
991
Vertical Termination (High Wind)
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Vent Parts List - Horizontal
Vent Parts List - Vertical
Direct vent pipe by Security or Simpson Dura-Vent may be used with
the Ravelle 42 gas fireplace. Please see the lists below to verify the
components available from each direct vent pipe manufacturer. All
horizontally terminated venting of the Ravelle 42 gas fireplace uses 8”
x 5” size vent pipe and all vertically terminated venting uses 6-5/8” x 4”
size vent pipe. The flue collar on the fireplace is 8” x 5” in size. Therefore,
when vertically terminating it is necessary to use a reducer - part number
75247 (available from Lennox Hearth Products) - to make the transition
from the 8” x 5” flue collar to the 6-5/8” x 4” pipe. Snorkel terminations
areavailableforapplicationswhichmayrequireverticalriseonthebuilding
exterior. The components listed below come in a galvanized finish. Most
of the components are also available in a painted black finish. Add a “B”
to the end of the part number when ordering if a black part is desired.
Direct vent pipe by Security™ or Simpson Dura-Vent may be used
with the Ravelle™ 42 gas fireplace. Please see the lists below to verify
the components available from each direct vent pipe manufacturer. All
horizontally terminated venting of the Ravelle 42 gas fireplace uses 8”
x 5” size vent pipe and all vertically terminated venting uses 6-5/8” x 4”
size vent pipe. The flue collar on the fireplace is 8” x 5” in size. Therefore,
when vertically terminating it is necessary to use a reducer - part number
75247 (available from Lennox Hearth Products) - to make the transition
from the 8” x 5” flue collar to the 6-5/8” x 4” pipe. Snorkel terminations
areavailableforapplicationswhichmayrequireverticalriseonthebuilding
exterior. The components listed below come in a galvanized finish. Most
of the components are also available in a painted black finish. Add a “B”
to the end of the part number when ordering if a black part is desired.
Security Secure Vent 6-5/8”x 4” Pipe
Security™ Secure Vent™ 8”x 5” Pipe
Part Number
SV4L6
SV4L12
SV4L24
SV4L36
SV4L48
SV4LA
SV4LA12
SV4FA
SV4FB
SV4RSM
SV4E46
SV4E90
SV4VS
SV4FC
SV4CGV
SV4BF
Description
6” Pipe Length
12” Pipe Length
24” Pipe Length
36” Pipe Length
Part Number
SV5L6
SV5L12
SV5L24
SV5L36
SV5L48
SV5LA
SV5LA12
SV5E45
SV5E90
SV5RSM
SV5VS
Description
6” Pipe Length
12” Pipe Length
24” Pipe Length
36” Pipe Length
48” Pipe Length
6” Pipe, Adjustable
12” Pipe, Adjustable
45º Elbow
48” Pipe Length
6” Pipe, Adjustable
12” Pipe, Adjustable
Flashing, 1/12 to 176/12 Roof Pitch
Flashing, 8/12 to 12/12 Roof Pitch
Wall Radiation Shield
45° Elbow
90° Elbow
Vinyl Shield Protector
Storm Collar
90º Elbow
Wall Radiation Shield
Vinyl Shield Protector
Firestop
Horizontal Termination Cap
Snorkel Termination (14”) Cap
Snorkel Termination (36”) Cap
Wall Band
SV5BF
SV5CHC-1
SV5STC14
SV5STC36
SV5BM
Vertical Termination Cap
Firestop
Wall Band
SV4BM
Simpson Dura-Vent GS 8”x 5” Pipe
Part Available from Lennox Hearth Products Only:
Part Number
1208
1207
1206
1204
1203
1202
1211
1217
1290
1247
1263
1288
1281
1282
1284
1285
1250
Description
6” Pipe Length
9” Pipe Length
12” Pipe Length
24” Pipe Length
36” Pipe Length
8” Pipe Length
11” to 14-5/8” Pipe, Adjustable
17” to 24” Pipe, Adjustable
90° Elbow
Wall Thimble
Ceiling Firestop
75247
8” x 5” to 6-5/8” x 4” Reducer
Simpson Dura-Vent GS 6-5/8” x 4” Pipe
Part Number
908
907
Description
6” Pipe Length
9” Pipe Length
906
904
12” Pipe Length
24” Pipe Length
903
902
36” Pipe Length
48” Pipe Length
911
912
917
942
11” to 14-5/8” Pipe, Adjustable
12” to 17” Pipe, Adjustable
17” to 24” Pipe, Adjustable
Wall Thimble
Wall Strap
Snorkel Termination (36”)
Snorkel Termination (14”)
Horizontal Termination Cap
Horizontal Termination Cap (High Wind)
Vinyl Siding Standoff
945
943
943S
953
45° Elbow
Flashing, 0/12 to 6/12 Roof Pitch
Flashing, 7/12 to 12/12 Roof Pitch
Storm Collar
963
988
Ceiling Firestop
Wall Strap
980
991
Vertical Termination Cap
Vertical Termination Cap (High Wind)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Supports: Horizontal runs of vent must be supported every three feet.
Wall straps are available for this purpose.
Vent Considerations
Twist-lock procedure: Four indentations, located on the female ends
of pipes and fittings, are designed to slide straight onto the male ends of
adjacent pipes and fittings by orienting the four pipe indentations so they
match and slide into the four entry slots on the male ends (see Figure
17). Push the pipe sections completely together, then twist-lock one sec-
tion clockwise approximately one-quarter turn until the two sections are
fully locked. The female locking lugs will not be visible from the outside
on the pipe or fittings. They may be located by examining the inside of
the female ends.
Pipe Sealing: If Security™ Secure Vent™ pipe is used, then sealant is
required at only the first pipe joint attaching the pipe to the flue collar on
the fireplace. If Simpson Dura-Vent GS pipe is used, then the pipe must
be sealed as follows: seal both the inner and outer pipes with a high
temperature silicone sealant rated for at least 600º F (commonly known
as “RTV”). Run a 1/8” (3mm) bead of silicone around the outside of the
male end of the outer sleeve. Run a 1/8” (3mm) bead of silicone about
1/4” (6mm) from the end of the male inner pipe, which is found in the
pipe to be attached above. Twist-lock the pipes or fittings together.
Female
Locking
Lugs
Sealant
Male
Locking
Lugs
Figure 17
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Horizontal Vent Installation
Vertical Vent Installation
IMPORTANT NOTES:
IMPORTANT NOTES:
1. All Ravelle™ 42 gas fireplaces horizontally terminated vent
installations use 8”x 5” Security™ Secure Vent™ or Simpson
Dura-Vent GS direct-vent pipe.
2. When this pipe passes through a wall, a wall thimble - Security
#SV5RSM or Simpson #1247 is required. The hole in the wall
for the wall thimble should be 10-3/4” x 10-3/4”.
3. Horizontal runs of vent must be supported every three feet.
Wallstraps-Security#SV5BMorSimpson#1288areavailable
for this purpose.
4. Iftheventpassesthroughaceilingorfloor,afirestop-Security
#SV5BF or Simpson #1263 is required.
5. Venting terminals shall not be recessed into a wall or siding.
If installing the termination cap on a wall covered with siding,
a vinyl siding standoff - Security #SV5VS or Simpson #1250
or furring strips must be used to ensure that the termination
cap is not recessed into the siding.
6. The horizontal run of vent must have a 1/4” (6mm) rise for
every 12” (305mm) of run towards the termination.
7. If the wall being penetrated is constructed of non-combus-
tible material, such as masonry block or concrete, an 8-1/2”
(216mm) diameter hole is acceptable and a wall thimble is
not required.
8. The location of the horizontal vent termination on an exterior
wall must meet all local and national building codes and must
not be blocked or obstructed. For allowable external vent
terminations locations, see the diagram on Page 20.
9. Allowableclearancesfromtheventpipetocombustiblemateri-
als must be maintained. See Page 7 for these clearances.
10. Do not locate the termination cap where it may be blocked by
shrubbery or snow.
1. AllRavelle42gasfireplaceverticallyterminatedventinstallations
use 6-5/8” x 4” Security or Simpson Dura-Vent GS direct-vent
pipe.
2. Fireplaces that are vertically terminated require pipe reducer
- Lennox Hearth Products #75247 - installed on the fireplace’s
flue collar before the
direct vent pipe can be installed.
3. If the vent passes through a ceiling or floor, a firestop - Security
#SV4BF or Simpson #963,
4. If the vent passes through the roof, a roof flashing - Security
#SV4FA or SV4FB, Simpson #943 or 943S and storm collar
- Security #SV4FC, Simpson #953 are required.
5. Allowable clearances from the vent pipe to combustible materi-
als must be maintained. See Page 7 for these clearances.
6. A maximum of two 45º elbows may be used. See Page 18 for
allowable offsets.
7. Themaximumsystemheightis30feet(9.1M)andtheminimum
is 10 feet (3 M).
Vertical Termination Cap
Security (Part #SV4CGV)
Simpson (Part # 980)
StormCollar
Flashing
Security (Part #SV4FC)
Secuirty (Part #SV4FA or SV4FB)
Simpson (Part # 953)
Simpson (Part # 943 or 943S)
Roof- Maintain 1”
(25mm) Clearance
to Combustibles
Termination Cap
10-3/4”x 10-3/4”
(ꢀ73mm x ꢀ73mm)
Framed Hole
CeilingMinimum
Framing 10” x 10”
(254mm x 254mm)
CeilingFirestop
Security (Part # SV4BF)
Simpson (Part # 963)
Pipe
Wall Thimble
Elbow
Length
Note:
Verifythatyouhave
at least the mini-
mum clearance to
combustiblesatthe
roofline.
Figure 19
Figure 18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Flue Restrictors
The flue restrictor settings shown in Figures 22 and 23 are for typical
installations and may need to be adjusted from standard to take into
accountothervariablesintheinstallationtoachievepropercombustion.
See Flue Restrictor Guidelines on this page to assist you in making a
proper flue restrictor adjustment.
Restrictors
The Ravelle™ 42 gas fireplace uses balanced flue technology to ensure
proper combustion. Flue restrictors may need to be installed depending
on the vent configuration of your fireplace. The drawings on Page 19
show all the allowable pipe configurations for the Ravelle 42 gas fireplace.
To properly install the flue restrictor, find your pipe configuration in the
drawings on Page 19 and note which restrictor setting is recommended.
The flue restrictors and four black self-tapping 5/32” allen head screws
can be found in the firebox in a plastic bag. The restrictors should be
placed over the openings at both sides of the ceiling of the firebox. For
each restrictor, two self-tapping 5/32” allen head screws should be in-
stalled in either holes 1, 2, 3, or 4 in the restrictor and screwed into the
two holes in the firebox ceiling. (There are four holes at each side of the
firebox ceiling to receive only two screws. Insert the screws into either
two holes). See the drawing to the right for the location of hole numbers
on the restrictor. The numbered holes in which the screws are inserted
in the restrictor should correspond to the restrictor position numbers
found on the drawings for your pipe configuration. Restrictor positions
are based on tests run in a laboratory. The optimum restrictor positions
may need to be adjusted slightly depending on the conditions surround-
ing the residential installation. Do not adjust restrictors to a point where
the fireplace is sooting.
Interior of Firebox
Figure 20
Vertical Vent Termination Clearances
The vent / air intake termination clearances above the high side of an
angled roof is as shown in the table below.
TERMINATION HEIGHTS FOR VENTS ABOVE
FLAT OR SLOPED ROOFS
Horizontal Overhang
Notes: The higher the number of the flue restrictor position, the greater
amount of combustion air will be delivered.
Figure 21
ꢀ FT
MIN.
Vertical
Wall
Flue Restrictor Adjustment Guidelines
ꢀ FT MIN.
Lowest
Discharge
Opening
After the flue restrictors have been set to the standard settings as shown
in Figures 22 and 23, the burner flame appearance should be evaluated
to determined if the flue restrictors need to be set to a different position
to adjust for variables in your installation. Light the appliance and allow
it to burn for 20 minutes. See Flame Color and Behavior on Page 30 to
determine if you have a proper burner flame appearance. If the proper
flame appearance cannot be achieved, the flue restrictor may need to be
set to a different position. See the following guidelines to determine if
you need to readjust the flue restrictors.
Vent
Termination
H*
Storm Collar
Flashing
X
1ꢀ
Roof Pitch is X/1ꢀ
1 inch (ꢀ5.4 mm) Minimum
Clearance to Combustibles
Beforeproceeding, confirmthemanifoldandinletgaspressureiscorrect,
primary air shutter is properly adjusted, venting system connections are
secure and not blocked and if you are at a high elevation, ensure unit has
been properly derated:
Concentric
Vent Pipe
*H = MINIMUM HEIGHT FROM ROOF TO
LOWEST DISCHARGE OPENING OF VENT
Termination Heights For Vents
Above Flat Or Sloped Roofs
Ref. NFPA 54 / ANSI Zꢀꢀ3.1
Symptoms - Lack of Combustion Air
If the symptoms listed below are present, you may need to adjust the
flue restrictor to a more open position.
• Flame appears yellow
Roof Pitch
Flat to 6/12
* Feet
1.0
*Meters
0.3
• Floating Flames (lazy, ill defined, quiet, may roll)
• Sooting
6/12 to 7/12
1.25
1.5
0.38
0.46
0.61
0.76
0.99
1.22
1.52
1.83
2.13
2.29
2.44
7/12 to 8/12
• Pilot becomes yellow and appliance shuts down
8/12 to 9/12
2.0
Symptoms - Excessive Combustion Air
9/12 to 10/12
10/12 to 11/12
11/12 to 12/12
12/12 to 14/12
14/12 to 16/12
16/12 to 18/12
18/12 to 20/12
20/12 to 21/12
2.5
3.25
4.0
If the symptoms listed below are present, you may need to adjust the
flue restrictor to a more closed position.
5.0
• Low Flame
• Pilot pulls and appliance shuts down
• Pilot flame ghosts
6.0
7.0
7.5
8.0
18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
Horizontal Terminations
(Use 8” Direct-Vent Pipe)
Vertical Terminations
(Use 6-5/8” Direct-Vent Pipe)
The shaded areas in the diagram below show all allowable combinations
of vent configuration with horizontal terminations. Horizontal sections
of pipe require 1/4” (6.4 mm) of rise for every 12” (305 mm) of run.
A second 90º or 45º elbow (in addition to the first 90º elbow at the top
of the vertical length of pipe) is allowed as long as the overall length of
the horizontal run of pipe does not exceed those shown below. Use the
restrictor positions indicated. If the fireplace is vented with an elbow
directly off the top of the flue collar and three to four feet of horizontal
pipe is used, then no restrictor is to be installed in the fireplace.
The shaded areas in the diagram below show all allowable combinations
of straight vertical and offset to vertical (maximum four 45º elbows or two
90º elbows) vent configurations with vertical terminations. The termina-
tion must fall within the shaded areas on the diagram. Use the restrictor
positions indicated. The maximum offset length at a 45º angle consists
of one three foot and one four foot section of pipe. The maximum height
is 30 feet (9.1 M) and the minimum is 10 feet (3 M).
Vertical Terminations
Horizontal Terminations
5 Ft. ꢀ In. (1.6M)
Maximum
30 Ft.
18 Ft.
(5.5M)
(9M)
15 Ft.
(4.6M)
Restrictor
Position #ꢀ
ꢀ5 Ft.
(7.6M)
10 Ft.
(3M)
Restrictor
Position #1
Restrictor
Position #3
ꢀ0 Ft.
(6M)
5 Ft.
(1.5M)
15 Ft.
(4.6M)
Restrictor Position #4
Restrictor
Position #ꢀ
No Restrictor
10 Ft.
(3M)
0 Ft.
(0M)
5 Ft.
(15ꢀ4M)
0 Ft.
(0M)
10 Ft.
(3M)
15 Ft.
(4.6M)
ꢀ0 Ft.
(6M)
Figure 22
5 Ft.
Snorkel Terminations: For installations requiring a vertical rise on the exterior
of the building, 14-inch (356 mm) and 36-inch (914 mm) tall snorkel terminations -
Security™#SV5STC14orSV5STC36andSimpson#1281or1282areavailable.Follow
the same installation procedures as used for standard horizontal terminations. If the
snorkel termination must be installed below grade (i.e. basement application), proper
drainage must be provided to prevent water from entering the snorkel termination.
Do not attempt to enclose the snorkel within the wall or any other type of enclosure.
On vinyl siding, furring strips may be used to ensure that the snorkel is not recessed
into the siding. NEVER install the snorkel upside down.
(15ꢀ4M)
0 Ft.
(0M)
Figure 23
5 Ft.
(15ꢀ4M)
0 Ft.
(0M)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Exterior Horizontal Vent Termination Clearance Requirements
* SeeItem D in the Text Below.
Center Line
ExteriorWall
Inside
Corner Detail
of Termination
*18”
Horizontal
G
Termination
18”
V
Ventilated Soffit
A
InsideCorner
= 9" in U.S.
= 1ꢀ" in Canada
A
DETAIL D
H
3 ft.
B
B
B
E
D
X
C
C
A
A
V
V
Fixed
Operable
Window
V
L
V
Closed
3 ft.
Window
V
F
J
M
V
C
B
B
C
V
I
A
X
= Air Supply Inlet
= Vent Terminal
= Area where Terminal is NOT permitted
V
Minimum Clearances
Canadian Installation *
US Installation **
A = Clearance above grade, veranda, porch, deck 12 inches (30 cm) *
or balcony.
12 inches (30 cm) **
B = Clearance to window or door that may be 6 in. (15.2 cm) for appliances < 10,000 BTU/hr (3kW),
6 in. (15.2 cm) for appliances < 10,000 BTU/hr (3kW),
opened.
12 in. (30 cm) for appliances > 10,000 BTU/hr (3kW) and < 9in.(23cm)forappliances>10,000BTU/hr(3kW)and<
100,000 BTU/hr (30kW), 36 inches (91 cm) for appliances 50,000BTU/hr(15kW), 12inches(30cm)forappliances
> 100,000 BTU/hr (30kW)*
> 50,000 BTU/hr (15kW)*
C = Clearance to permanently closed window
12 inches (305 mm) recommended to prevent window 9 inches (229 mm) recommended to prevent window
condensation
condensation
D = Vertical clearance to ventilated soffit located 18 inches (458 mm)
abovetheterminalwithinahorizontaldistanceof18
18 inches (458 mm)
in. (458 mm) from the center line of the terminal
E = Clearance to unventilated soffit
F = Clearance to outside corner
G = Clearance to inside corner
12 inches (30 cm)
5 inches (12.7 cm)
6 in. (15 cm)
12 inches (30 cm)
5 inches (12.7 cm)
6 in. (15 cm)
H = Clearance to each inside of center line extended 3 feet (91 cm) within a height of 15 feet above the meter / 3 feet (91 cm) within a height of 15 feet above the meter
above meter / regulator assembly
regulator assembly *
/ regulator assembly **
I = Clearance to service regulator vent outlet
3 feet (91 cm) *
3 feet (91 cm) **
J = Clearance to non-mechanical air supply inlet 6 in. (15.2 cm) for appliances < 10,000 BTU/hr (3kW), 12 6 in. (15.2 cm) for appliances < 10,000 BTU/hr (3kW), 9
to building or the combustion air inlet to any other in. (30 cm) for appliances > 10,000 BTU/hr (3kW) and < in. (23 cm) for appliances > 10,000 BTU/hr (3kW) and <
appliance
100,000 BTU/hr (30kW), 36 inches (91 cm) for appliances 50,000BTU/hr(15kW), 12inches(30cm)forappliances
> 100,000 BTU/hr (30kW)*
> 50,000 BTU/hr (15kW)*
K = Clearance to mechanical air supply inlet
6 feet (1.8 meters) *
3 feet (91 cm) above, if within 10 feet (3 m) horizon-
tally**
L = Clearance above paved sidewalk or paved 7 feet (2.13 m) ‡
driveway located on public property
7 feet (2.13 m) ‡
M = Clearance under veranda, porch, deck or 12 in. (30 cm) * ‡
balcony
12 in. (30 cm) ** ‡
* In accordance with the current CSA/CAN-B149.1 National Gas and B149.2 Propane Installation Code - Latest Editions.
** In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Codes - Latest Edition.
‡ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
*‡ Only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor.
Figure 24
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ꢀ0
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Place Log #6 on tab located on right side of firebox. The other end of
the log is placed on the burner.
7. Volcanic stone may be placed along the front edge of the burner, but
not directly over the burner ports.
Brick Panel and Log Set Installation
Brick Panel
The brick panels are extremely fragile so handle them with care.
1. Remove brick panels from box and wrapping.
Insert
Tabs
2. The long rectangular panel goes in the rear of the firebox - the thin layer
ofbricksshouldbedown.Thepanelrestsonthreemetaltabsprotruding
from the rear of the firebox about 3” above the firebox floor.
3. On the side panels, the rounded edge goes to the front. Install the side
panels by sliding them along the side of the firebox into retainers at
the top and bottom.
Rockwool
Important!!! Maintain a 1/4” (6.4mm) air
space along the entire length of log.
Figure 26
Log #6
Figure 25
Log Set and Embers
Firebox Accessories / Parts
Cat. No.
H5859
H5863
H5864
Description
Log Set
Bag of Embers (volcanic stone)
Bag of Rockwool (glowing embers)
Log Installation Instructions
Volcanic Stone
Embers
Figure 27
If logs are not installed according to the log installation instructions,
flame impingement and improper combustion could occur and result
in soot and/or excessive production of carbon monoxide (CO), a color-
less, odorless, toxic gas.
Log Locater
Tab for Log #6
Log #3
The size and position of the log set is critical to achieve a safe, reli-
able and attractive flame pattern. Any attempt to use a different log
set in the fireplace will void the warranty and will result in incomplete
combustion, sooting and poor flame quality.
1. Remove the six logs from the box and foam packaging. Lay them out
for easy identification during installation.
Log
#4
2. Place rear log on insert tabs (these tabs will penetrate the center of
the log) at the rear of the burner.
Log
#ꢀ
3. Place a light (fluffed) layer of embers (rockwool) directly on top of
the port holes in the burner. CAUTION: A 1/4” (6.4mm) air space
between the rockwool and lower base of the rear log needs to be
maintained for combustion air and proper flame aesthetics.
4. Place Log #2 on tab. An air shield is provided for natural gas use only.
For LP conversions, remove the air shield.
Log #5
Air Shield
Figure 28
5. Place Logs #3, #4 and #5 on tab inserts.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ꢀ1
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Connections:
B
* Thebreakersupplyingelectricitytothefireplacemustbeturnedoffatthe
electrical panel before any connections are made at the fireplace.
* The wire supplying the fireplace should be a minimum of 14 gage and
provide 120 Volts at 60 hz.
* The fireplace must be grounded in accordance with local electrical
codes or, in the absence of local codes, with the National Electrical
Code or ANSI/NFPA 70 - latest edition.
* Theelectricalboxislocatedattherightrearofthefireplace(seeFigures
29 and 30). Remove the cover, loosen the wire clamp A and feed the
household supply line through the clamp and retighten clamp.
* Connect the supply ground wire to the green screw B.
* Remove the wire nut C from the black wires coming from the fireplace
and join these wires to the black supply wire reusing the wire nut.
Repeat for white wires.
* Reinstall the cover to the fireplace.
* If a wall-mounted burner on/off switch or thermostat is to be used,
the wires running from the switch or thermostat should be routed to
the left side of the fireplace. The wire should be fed through the gas
line supply hole along the gas line to the valve.
Figure 30
A
E
Wall-Mounted Fan Speed Control:
If desired, a wall-mounted fan speed control can be installed. The breaker
supplying electricity to the fireplace must be turned off at the electrical
panel before any connections are made. The loop of wire with the label
attached (E in Figure 29) may be cut and the wire leads from the wall-
mounted speed control connected to each end of the cut wire.
D
Optional Heat Ducting System:
The remaining red and white wires with capped ends (wires D in Figure
29) are for the optional Forced Air Heating System. See the instructions
provided with the system for installation details.
C
Figure 29
Fan Wiring Diagram
Snap Switch (Contacts Close When Fireplace is Hot)
Speed Control
Green (Ground)
Black (Hot)
From Power Source
White (Neutral)
Black
Black
Red
To Optional Heat Duct Fan
White
Blower
Figure 31
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ꢀꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
If the pressure is not sufficient, make sure the gas supply line is large
enough, the supply regulator is properly adjusted and the total gas load
for the residence does not exceed the amount supplied.
Gas Line Installation
The Ravelle™ 42 gas fireplace must be connected to the gas line in ac-
cordancewithlocalcodesand/ortheNationalFuelGasCode,ANSIZ223.1
(In Canada, the current CAN/CSA B149.1 installation code). The gas line
should enter the fireplace on the left side (see diagrams on Pages 8 and
9). If the gas line enters the unit from the right side, the line will need to
be disconnected to remove the fan. The fireplace comes with a flex line
attached to the supply side of the gas valve. The fitting on the end of the
flex line can receive a 1/2” female iron pipe coupling, a 3/8” male iron
pipe, or a shut-off valve. There is sufficient room to locate the shut-off
valve under the firebox at the end of this flex line, however, local codes
may require the shut-off to be located on the exterior of the fireplace. After
connecting the gas line, all joints in the line and connections at the valve
should be checked for leaks before final positioning of the unit. Conduct a
gas leakage test of the appliance piping and control system downstream
of the shutoff valve in the supply line to the appliance.
Note: Theapplianceanditsindividualshut-offvalvemustbedisconnected
from the gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 psig. The appliance must be
isolated from the gas supply piping system by closing its individual
manualshut-offvalveduringanypressuretestingofthegassupplypiping
system at test pressures equal to or less than 1/2 psig. Check with your
gas supplier or plumber.
Fuel
Type
Inlet Pressure
Manifold Pressure
Desired Minimum Maximum
On Hi
Fire
On Lo
Fire
Natural 7" WC
Gas
5" WC
10.5" WC 3.5" WC 1.7" WC
Gas Pressure Requirements
LP Gas 11" WC 11" WC
13" WC 11" WC 5.4” WC
A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLI-
ANCES IS IMPROPER GAS PRESSURE!
SIT Millivolt Gas Valve
The most important item to check during the initial installation
and the first thing to check when operating problems occur is
gas pressure!
TH
TP
This fireplace will not function properly unless the required
gas pressure is supplied. See the table on this page for gas
pressure requirements.
TP/TH
Inlet (Supply)
Pressure Tap
The Manifold
(Outlet) Tap
Two pressure taps are provided on the fireplace’s valve to check gas
pressures. To access the taps remove the two socket head screws to
remove the valve control panel/heat shield. The taps are located below
the on/off/pilot knob (see Figure 32). The left tap is the inlet (supply)
pressure side. To check inlet pressure (with the fireplace burning) insert
a small flat bladed screwdriver into the tap and turn a half turn counter-
clockwise. Cover the tap with the line from a manometer and read the
pressure. Close the tap gently but securely after completing the check.
The manifold (outlet) tap is to the right of the inlet tap. To check manifold
pressure (with the fireplace burning at the high burn setting) insert a
small flat bladed screwdriver into the tap and turn a half turn counter-
clockwise. Cover the tap with the line from the manometer and check
the pressure. Again close the tap gently but securely after completing
the check. Check the taps for gas leaks with a gas leak test solution
(retighten if necessary).
Figure 32
LP and Natural Gas Supplies
Your Ravelle gas fireplace is equipped from the factory for use with
natural gas only as specified on the Safety / Listing label attached to the
appliance. This appliance can only be operated using propane gas (LP)
if a certified fuel conversion kit provided by Lennox Hearth Products is
installed by a qualified service technician.
Also check the orifice size on the label on the igniter bracket. It must be
the correct size for the fuel and altitude.
Do not run propane tank dry. Running the tank dry may cause a
hazardous condition due to pressure drop in empty tank.
Solid fuel is NOT to be used with this unit.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ꢀ3
Download from Www.Somanuals.com. All Manuals Search And Download.
Increasing Efficiency and Hot Air Movement
Possible Opening
and Grill Locations
on Cabinet
Anumberofdifferentoptionsareavailabletothehomeownertomaximize
the heat output and air movement to different rooms in the house.
Grills:IfyourRavelle™42gasfireplaceisinstalledinacabinetorachase,
heat can be drawn from these enclosures and circulated into the living
area by cutting one or two openings covered by a register or Grill.
Opening and Grill into
Adjoining Room
Figure 34
Whole Home Comfort System: The Whole Home Comfort System is a
very inexpensive and efficient way to move air into and heat other areas
of the house. In the bottom of the Ravelle™ 42 gas fireplace are four inch
and Six inch (152 mm) diameter knock-out plates. Four inch (102 mm)
or six inch (152 mm) diameter return air ducting may be fastened to the
bottomofthefireplace,runintoanotherroominthehouseandterminated
with a grill. When the fireplace is burning, with or without the fireplace
fan running, air is drawn from a distant room (lowering the pressure in
that room) through the return air duct into the bottom of the fireplace.
The air then passes through the outer shell and heat exchanger of the
fireplace and into the room in which the fireplace is located. The hot air
in the fireplace room moves through an open doorway or hall into the
low pressure room from which the air was drawn. This system functions
well by convection even without the use of the fireplace fan. Six inch (152
mm) diameter ducting moves more air than four inch diameter ducting.
Ducting in uninsulated areas of a house (for example in the crawl space)
shouldbewrappedininsulationtoensuremaximumheatretention.Check
local building codes - some areas may require firestops when the duct
passes from room to room.
Figure 33
Note: Grill can be in the Wall, Ceiling, or Floor.
Up to 100 Feet (30.5M)
Maximum Run
Starter Ring
4” (10ꢀmm) or
6” (15ꢀmm)Duct
Figure 35
ꢀ4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
The system draws heated air from the Ravelle 42 gas fireplace and moves
it with the use of a 150 CFM fan through six inch ducts into other rooms
in the house. The system acts as a forced air furnace. One or two systems
can be used with each Ravelle 42 gas fireplace.
Forced Air Heating Installation
Hot air can be drawn off the Ravelle™ 42 gas fireplace and moved into
other rooms of the house with the forced air heating system. This system
can be purchased as an option from your Lennox Hearth Products dealer
(part #75134).
SYSTEM OVERVIEW
System Overview
Fan Box
Blower Box
Duct Adapteto
Duct Adapter (6” round to
Six Inch Duct (20' maximum length)
Six Inch Duct (ꢀ0 ft. maximum length)
10” x 3-1/4” rectangular)
Fireplace Side Adapter
Fireplace Side Adapter
Switch Box
Switch Box
Fan Speed Control
Blower Speed Control
Wall Stack Duct (10" x 31/4") for use
Wall Stack Duct (10” x 3-1/4”) for use in
areas of restricted clearance (not included
as part of the kit - available at major
Figure 36
hardware stores)
Fan Box
Blower Box
FORCED AIR KIT COMPONENTS
Forced Air Kit Components
Flapper
C
Co
o
v
e
e
r
Pla
r Pl
Flapper Plate
Starter Ring Adapter
g Adapter
Starter Ring
ex Duct
Six Inch Flex Duct
Additional Parts:
Additional Parts:
Duct Adapter
D
Two Angled Mounting Brackets
Blower Box
Two White - Headed Grill Screws
Spacer
Six Wire Nuts
Sixteen Sheet Metal Screws
One Wire Clamp
Floor Mount
Floor Mount
Adapters
Grilli
Two Switch Boxes, Two Covers and Two Speed Control Knobs
Speed Control
Speed Control
Figure 37
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ꢀ5
Download from Www.Somanuals.com. All Manuals Search And Download.
The fan box may be located in the wall, floor, or ceiling.
Ceiling and Wall Mounting:
1) Fasten the two angled brackets to the side of the face box with the screws provided (see A below).
2) Fasten the bracket in these
2
holes for 2 x 4 walls.
A
3) Thenfastentheblowerboxtothe
ceiling rafters or wall studs.
F
Fasten the bracket in
these holes for ꢀ x 6 or
t
greater walls or ceiling.
Figure 38
Floor Mounting:
1. Fasten the two floor mount adapters (B below) to the side of the fan box with the screws provided. The floor mount adapters have two sets of holes.
The upper holes (C below) should be used if the flooring material is thin and the lower holes (D below) should be used if the flooring material is
thick.
2. Cut the hole (E below) for the fan box. Since the fan box body is wider than the portion that comes up through the floor an additional piece of floor-
ing (F below) should also be cut out for the fan box to slide through. (Save this piece F and nail it back in place after the fan box is installed).
3. Slide the fan box through the cut holes and nail or screw it to the floor.
B
2”
5”
16”
E
14”
14”
C
D
F
C
Figure 39
C
D
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ꢀ6
Download from Www.Somanuals.com. All Manuals Search And Download.
Duct Assembly:
The duct has zero clearance to combustibles.
1. Remove the cover plate from the top of the fireplace. Save the screws and discard the plate.
2. Insert the starter ring into the starter ring adapter and bend the tabs under to secure the ring to the adapter. See the expanded view below.
3. Place the adapter with the attached starter ring over the flapper plate and secure them to the top of the fireplace using the four screws that held
the cover plate.
4. Fasten the remaining components of the duct: flex line, duct adapter, wall stack and fan box using at least three sheet metalscrewsandaluminum
duct tape at each joint.
5. Secure the ducting to prevent sagging.
anded View
Expanded View
Bend Tabs Under
Cover Plate
Flapper Plate
Starter Ring Adapter
Starter Ring
Figure 40
Wiring of the Forced Air System:
Disconnect the electrical supply to the fireplace at the electrical panel prior to wiring the forced air system fan. All wiring should be done by a quali-
fied electrician.
1. After installing the fan box and ducting from the fireplace to the fan box, the wiring of the fan box should be undertaken. Included in the ducting kit
are two electrical switch boxes. One is for installation in new construction and the other is to be used in a remodel. Select the switch box needed
and fasten it to the wall framing in the room in which the fan box is located.
(Instructions continue on the following page).
Speed Control
Black (Hot)
Supply Leads
White (Neutral)
from Fireplace
Green (Ground)
Blower
Figure 41
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ꢀ7
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring of the Forced Air System Continued:
2. Remove the cover over the electrical box at the right lower rear of the
fireplace. Run sheathed wire from the fireplace electrical box to the
switch box and from the switch box to the fan box. Install the wire
clamp in the unused knock-out hole in the fireplace electrical box
cover. Run the end of the sheathed wire through this wire clamp. In the
electrical box are a white wire and a red wire with clear caps on their
ends. Remove these caps and join the red wire and black wire with
the wire nuts provided. Also join the white wire from the fireplace with
the white wire from the sheathed wire using the wire nuts provided.
Fasten the ground wire from the sheathed wire to the green grounding
screw in the electrical box. When the fireplace gets up to temperature,
a heat activated switch will close and allow electricity to flow to the
red wire.
Grill Spacer
3. At the switch box, cut the black sheathed wire, strip back the insula-
tion and join each end (with the wire nuts provided) to a lead from the
speed control. It does not matter which lead from the speed control is
fastened to which black wire. After making these connections, roll the
connectorsandwireintotheswitchbox. Twodifferentcolorsofcovers
and knobs come with the kit. Select the cover desired and fasten the
speed control and cover to the box with the screws supplied. Push
the desired knob onto the shaft of the speed control.
Grill
Figure 42
4. Remove the four screws holding the fan to the fan box and lift fan out
of the fan box (see Figure 43). Feed the sheathed wire A through the
wire clamp B. Remove the insulation from the sheathed wire and the
two wires coming from the fan motor. Join together using the wire
nuts provided the black wire from the motor and the black sheathed
wire. Also join the two white wires. Fasten the ground wire to the green
grounding screw inside the fan box. Reinstall the fan in the fan box
using the four screws.
Notes:
The speed of this forced air system fan can be controlled by the speed
control that is installed with it. The speed control also has an off position.
This fan is energized only when the fireplace is up to temperature. It will
also shut off automatically when the fireplace cools down.
To maximize hot air distribution, this forced air system can be used in
conjunction with the Whole Home Comfort System described in this
manual.
C
Grill Installation: The Grill that covers the fan box is secured with the
two white-headed screws provided. When the fan box is mounted in a 2”x
4”framedwalltheboxwillextendpastthesheetrockedwallintotheroom.
In these installations the Grill spacer should be used (see Figure 42).
A
B
Figure 43
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
ꢀ8
Download from Www.Somanuals.com. All Manuals Search And Download.
C. Use only your hand to push in or turn the gas control knob.
Never use any tool. If the knob will not push in or turn by hand,
don't try to repair it, call a qualified service technician. Force or
attempted repair may result in a fire or explosion.
D. DO NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
Operating Instructions
Pre-Lighting Checklist
Be sure to check these items before the initial lighting of the
fireplace:
cThe fireplace gas label corresponds to the gas supply available
- that is "natural gas" for natural gas or "LP gas" for Propane
gas.
cGas pressure has been checked carefully - see Page 23.
cAll gas fittings have been checked for leaks.
cAll clearances to combustibles have been met - see Page 7.
cAll combustible materials have been removed from the area in
front of the fireplace.
OPERATING INSTRUCTIONS
CAUTION: YOUR Lennox Hearth Products gas FIREPLACE MUST
ALWAYS BE OPERATED WITH GLASS IN PLACE.
cAll vented areas of the fireplace face are unobstructed.
cHouse is ventilated to clear initial paint curing odors - see Page
31.
cAll packaging materials have been removed from the firebox.
cWhile fireplace is cool, fingerprints or other marks have been
cleanedfromanygoldornickelsurfaceswithdenaturedalcohol
andasoftcloth.Marksleftonthesesurfacesmaybecomeetched
into the finish if not removed prior to burning the unit.
cBrick panel, log set, volcanic stone and embers have been
installed.
STOP!! Read the safety information above before proceeding.
1. Open the lower door. Make sure gas supply shut-off cocks are
open and ON/OFF rocker switch is "OFF." If equipped with a
thermostat, set it to the lowest setting.
2. Turn off all electrical power to the appliance.
3. Push in gas cock dial slightly and turn clockwise
"OFF."
to
Note: Dial cannot be turned from "PILOT" to "OFF" unless dial
is pushed in slightly. Do not force.
4. Wait five minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow "B"
above. If you don't smell gas continue.
5. Locate the pilot by looking at the left center of the burner,
under the left elevated log. Blue flame will be seen when the
pilot is lit.
cThe glass door is in place and is properly sealed.
Lighting Instructions
The following is a copy of the operating and lighting instructions
found with each fireplace:
6. Turn the gas control knob counter-clockwise
"PILOT" position.
to the
FOR YOUR SAFETY READ BEFORE OPERATING
7. Push the knob all the way in and hold in that position. Im-
mediately light the pilot by pressing the igniter button several
times until pilot is lit. Continue to hold the knob in for about
30 seconds after the pilot is lit. Release knob and it will pop
back out. Pilot should remain lit. If it goes out, repeat steps
4-8 holding knob in an additional 15 seconds after pilot is lit.
If knob does not pop out when released, stop and immediately
call your service technician or gas supplier. If the pilot will not
stay lit after several tries, turn the gas control knob to "OFF" and
call your service technician or your gas supplier.
8. After pilot is lit, turn gas control knob counter-clockwise
to "ON." Knob can only be turned to "ON" if the knob
has popped out.
9. To turn burner on, turn "ON/OFF" rocker switch to "ON" or
set the thermostat to the desired temperature above room
temperature.
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROP-
ERTY DAMAGE, INJURY, OR LOSS OF LIFE.
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP
CHILDREN, FURNITURE, GASOLINE AND OTHER LIQUIDS WITH
FLAMMABLEVAPORSAWAY.NEVEROPERATEUNITWITHGLASS
OFF OR ATTEMPT TO REMOVE THE GLASS WHILE HOT.
A. This appliance is equipped with a piezo ignition device to light
the pilot. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING, smell around the appliance area for gas.
Be sure to smell next to the floor, because some gas is heavier
than air and will settle on the floor.
10. Adjust the flame height (and heat output) by turning the flame
WHAT TO DO IF YOU SMELL GAS:
height knob clockwise
for full flame and counter-
clockwise for reduced flame.
DO NOT try to light the appliance.
DO NOT touch any electric switch,
DO NOT use any phone in the building. Immediately call your
gas supplier from a neighbor's phone. Follow the gas supplier's
instructions. If you cannot reach your gas supplier, call the fire
department.
11. Turn on the electric power to the appliance and set the blower
to the desired air flow after it turns on when the appliance
reaches operating temperature.
ꢀ9
Download from Www.Somanuals.com. All Manuals Search And Download.
TO TURN OFF GAS TO APPLIANCE
SIT Millivolt Gas Valve
1. Turn off the "ON/OFF" rocker switch and/or thermostat (if
installed) to its lowest setting.
2. Turn off electric power to the appliance if service is to be
performed.
TH
TP
TP/TH
3. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
GasControlKnob
(Pilot/On/Off)
FlameHeightControl
Knob(HI/LO)
This appliance needs fresh air for safe operation and must be
installed so there are provisions for adequate combustion and
ventilation air.
PiezoIgniter
Allumeur
ON/OFFSwitch
Interrupteur
SHUTDOWN PROCEDURE
To turn off the burner, turn the rocker switch to "OFF" or adjust
the thermostat (if installed) to a setting below room temperature.
The pilot will remain lit for future burner ignition. For complete
shutdown, see "TO TURN OFF GAS TO APPLIANCE" above.
Gas Pilot Hood
Veilleuse à gaz
Thermopile
Igniter (electrode)
Allumeur
Thermocouple
WARNINGS
• Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. For assistance or additional
information,consultaqualifiedinstaller,service
agency or your gas supplier.
• Operation of this appliance when not connected
to a properly installed and maintained venting
system can result in carbon monoxide (CO)
poisoning and possible death.
Figure 44
PILOT ASSEMBLY
Flame Color and Behavior
Your Ravelle™ 42 gas fireplace is designed for maximum heating ef-
ficiency. Therefore, upon lighting of the main burner the flames will be
semi-transparent or “bluish.” After 10-20 minutes of operation the logs
will heat up and the flames will become a yellow/orange color.
• Carbon monoxide poisoning – Early signs of
carbon monoxide poisoning resemble the flu
with headaches, dizziness, or nausea. If you
have these signs, get fresh air at once! Have
the heater inspected by a qualified service
technician. Some people are more affected by
carbon monoxide than others. These include
pregnant women, people with heart or lung
disease or anemia, those under the influence
of alcohol and those at high altitudes.
Adjusting the fireplace to cause the flames to turn orange sooner may
result in poor combustion, sooting and a hazardous situation. See Figure
45 showing proper flame appearance.
When testing for proper operation - If an optional thermostat is installed
adjust it to its highest temperature setting. Visually determine that main
burner gas is burning properly: i.e., no floating, lifting or flashback.
Adjust the primary air shutter(s) as required. Check for proper main
burner operation at both high and low flame.
Burner Flame Appearance
Soot above
Flame Tip
Soot at
Flame Tip
No Soot at
Flame Tip
Dark Orange
Flame
Semi-Transparent
Yellow Flame
Ports on Burner
Assembly
No Blue Flame
Center
Blue Flame
Center
PROPERLY
BURNING FLAME
IMPROPERLY
BURNING FLAME
Figure 45
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Air Shutter Adjustment
Quiet Operation
The Ravelle™ 42 gas fireplace has an air shutter control lever located
at the upper left corner beneath the firebox (see Figure 46). The lever
is linked to the primary air shutter on the main burner. The air shutter
regulates the amount of primary air the burner receives and therefore
how clean the fireplace burns. The air shutter should only be adjusted by
a qualified gas technician. The fireplace should burn for about 15 minutes
with the logs installed before adjusting the air shutter. Moving the lever
to the left will open the shutter and turn the flames more transparent
and blue. Moving the lever to the right will close the shutter and turn the
flames more orange.
As the Ravelle 42 gas fireplace is burning a number of normal operational
sounds may be heard. The flow of gas through the gas valve and orifice
may make a rushing or whistling noise. If this noise is objectionable,
it can be reduced by turning down the flame. Turning down the flame
can reduce total heat output by more than 30%. When the blower turns
on, the sound of rushing air may be heard. The blower sounds may be
reduced by adjusting the speed control located behind the lower door.
Also, a slight clicking sound may be heard as the gas valve or blower
switch turn on and off.
Blower Operation
CAUTION: The air shutter should never be set so as to make the tips of
the flames sooty or create sooting on the viewing glass, logs, or heat
exchanger. If soot begins to form after burning, the air shutter should
be opened gradually until the sooting condition stops. Gas quality and
gas pressure may vary which can affect the burning characteristics of
the fireplace.
Your Ravelle 42 gas fireplace comes equipped with a 200 CFM blower
with a variable speed control and an automatic temperature activated
on/off snap switch.
Operation:
1. After the fireplace warms up, a heat activated switch will turn on the
fan. A fan speed control is located behind the lower door. The speed
control has an off position and the knob can be rotated to set the fan
at the desired speed. The fan will not operate until the fireplace is
warm.
2. Once the fan turns on, set the speed control knob to the desired
speed. No further adjustment is necessary, the fan will turn on and
off automatically whenever the fireplace is warm.
3. If you do not wish to have the fan on, turn the speed control knob
until it clicks to the “OFF” position.
Expanded View of Air
Shutter Control Lever
Optional Wall Thermostat
If an optional wall thermostat is to be installed, install the thermostat per
the manufacturers instructions (provided with the thermostat). Failure
to follow manufacturers instructions could result in a malfunction. Pay
special attention to the thermostat location requirements. If the loca-
tion requirements are not adhered to the appliance, erratic operation or
failure may occur.
Open Close
Figure 46
Paint Curing
Do not mount the thermostat where it may be affected by:
This fireplace has been painted with a high temperature metallic paint. It
leaves the factory dry to the touch, but completes the curing process as
the fireplace is used. To cure the paint, burn the appliance four successive
times for 10 minutes each time with a five minute cool down between
each firing. Also some parts of the appliance may be lightly coated with
machining oil. Ventilate the house during these first firings as the paint
and oil give off unpleasant odors. It is recommended that persons sensi-
tive to an imbalance in the indoor air quality avoid the fireplace during
the curing process.
• Radiant heat from this appliance, fireplaces, sun or other heat
sources.
• Drafts or dead spots behind doors or in corners.
• Hot or cold air from ducts.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Options
Thermostat Wire
Wire Size
1ꢀ Gage
14 Gage
16 Gage
18 Gage
ꢀ0 Gage
Maximum Length
100 Feet
64 Feet
Your Ravelle™ 42 gas fireplace comes equipped with an “On/Off” rocker
switch used to turn the burner on and off while the pilot light is on. The
switch is a round rocker switch located behind the lower door of the
fireplace’s face.
40 Feet
A wall-mounted switch, a millivolt wall thermostat, or a remote control
can be used to supplement the rocker switch. The gas valve is powered
by millivolts generated by the pilot assembly. This millivolt system is
very sensitive to electrical resistance, therefore make sure all connec-
tions are tight, clean and free from corrosion. Do not splice any millivolt
wires. Consult the table on this page to determine the proper gage of
wire for the thermostat or wall switch connections. This table refers to
the total length of the wire (out to the switch and back). The thermostat
must be a millivolt type. A 24-volt furnace thermostat will not work.
Never hook up household current - 120 Volts - to the millivolt system.
It is not recommended to hook up any more than two switches to the
fireplace (for example a rocker switch and a wall thermostat). Additional
switches may affect the system resistance and increase the chance of
the burner not igniting.
ꢀ5 Feet
16 Feet
Millivolt Control System
This fireplace operates on a millivolt control system. As such, no addi-
tional power supply is needed for the fireplace to heat. The pilot assembly
contains a thermocouple, that when heated by the pilot flame, generates
electricity (millivolts- mV=1/1000 of a volt) which opens a valve allow-
ing gas to flow to the pilot assembly. The pilot assembly also contains a
thermopile, that when heated by the pilot flame, generates electricity that
flows to terminal #1 (labeled THTP) on the gas valve. When the electricity
is conducted from terminal #1 through the on/off switch, thermostat,
or receiver of the remote control to terminal #3 (labeled TH) on the gas
valve, the main burner will ignite.
Follow the instructions included with the thermostat or remote control
for wiring. The thermostat, remote control and rocker switch will turn the
burner on and off independently. Be sure to set the rocker switch to the
“Off” position when using the thermostat or remote control and set the
thermostat or remote control to the lowest temperature when you wish
to use the rocker switch only, otherwise one may override the other.
Millivolt Control Schematic
Pilot Hood
Piezo Igniter
Sparker
Wiring Terminals
TH
Thermocouple
Pilot Assembly
Thermopile
TP
TH/TP
Pilot Gas Line
White
Brown
Gas Inlet
ON/OFF Rocker Switch, Thermo-
stat, or Remote Thermostat
Figure 47
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
3ꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
Millivolt and System Checks
MAINTENANCE AND SERVICING
Maintenance Checklist
Check
Test
To
Test
Connect
Meter
Thermostat Meter Read-
Connects
ing
Should Be
Leads to
Terminals
The following should only be performed by a qualified service techni-
cian.
A
B
C
Complete
System
ꢀ & 3
1 & ꢀ
ꢀ & 3
Closed
Open
100 MV
or More
Thermopile
Output
Greater Than
3ꢀ5 MV
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
System
Resistance
Closed
ꢀ.5 Ohms
1. Annual inspection should be made and the following checks per-
formed:
Proper Pilot Flame Appearance
oWhen unit is cool, glass viewing door and inspect burner for dirt, soot
and lint accumulations and remove if necessary. If excessive soot ac-
cumulation is present on burner, have a qualified service technician
adjust the burner for proper combustion.
o Clean inside of glass with gas fireplace glass cleaner. NEVER attempt
to remove or clean the glass when the unit is hot.
o Check the hot air outlet vents for lint or other accumulations. Never
block or restrict vent openings, obstruct flow of ventilation air, or use
vents other than those approved for use with this appliance.
o Check that direct vent pipe, air intake and flue are open and free of
soot, blockage, or debris.
o Check gaskets once a year. Gaskets must be tight. Replace if neces-
sary.
o Inspect the pilot system for proper flame. NEVER ADJUST THE PILOT
until after the gas pressure has been checked and supply lines have
been completely bled (this may take an hour or more when bleeding
throughthepilot). Allpilotsarecheckedandburnedatthefactoryprior
to shipment. The pilot adjustment screw is located to the upper right
of the flame height control knob. Adjust the pilot screw to properly
size the flames. Flames should completely surround the thermopile
and thermocouple and extend across the main burner tube ports. Be
careful not to back the screw out of its threads. Check for gas leaks
using a gas leak test solution.
Figure 48
Vent Pipe Maintenance
Conduct an inspection of the venting system semi-annually. Recom-
mended areas to inspect are as follows:
o Check that the area around the fireplace is kept clear and is free of
combustible materials, gasoline and other flammable vapors and
liquids.
1. Check areas of the venting system which are exposed to the elements
for corrosion. These will appear as rust spots, streaks, or in extreme
cases, holes. These components should be replaced immediately.
o Check the millivolt system as per the table on this page.
2. Remove the cap and shine a flashlight down the vent. Remove any
bird nests or other foreign material.
ꢀ. The viewing glass should be cleaned periodically (see Glass Main-
tenance).
3. Check for evidence of excessive condensate, such as water droplets
forming in the inner liner and subsequently dripping out at joints.
Continuous condensate can cause corrosion of caps, pipe and fittings.
It may be caused by having excessive lateral runs, too many elbows,
or exterior portions of the system being exposed to cold weather.
3. Should repairs or maintenance of the fireplace require the disas-
sembly of the vent/air intake system, the reassembly and resealing
should be completed by a qualified service technician and follow
the instructions on Page 16 of this manual.
4. Inspect joints to verify that no pipe sections or fittings have been dis-
turbed and consequently loosened. Also check mechanical supports
such as wall straps or plumbers’ tape for rigidity.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Opening and Removing Door
Blower Removal
Disconnect the power supply at the household electrical panel prior to
blower removal. The blower can be accessed through the lower door on
the fireplace face.
CAUTION: Do not open the glass door when the fireplace is
burning. Let the unit cool before opening the door. At the top
of the glass door are two spring-loaded latches. While holding
the door against the firebox, pull each latch forward and up -
releasing the top of the glass door. To remove the door, grasp it
firmly with both hands and lift it up so the two tabs at the bottom
of the door are lifted out of their retaining slots. The glass door
is quite heavy, so it is important to place it in a secure spot until
reinstalled. To reinstall the door, the tabs at the bottom of the
door must be inserted in the slots at the bottom of the firebox.
The spring loaded latches must be pulled forward and down to
apply pressure against the door.
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
SeethefanwiringdiagramonPage22forreference.Theblowerislocated
at the rear of the open area beneath the firebox. (During installation of
the fireplace, if the gas line was fed in from the right side it will now need
to be removed). To remove the blower, disconnect the wiring by pulling
the two spade connectors loose at the blower motor. The blower rests
on two pins - one located at each end of the blower. Grasp the blower
assembly at each end and pull the blower forward off the two pins. (If the
blower assembly is pulled from the center, it may distort the assembly).
The blower can then be carefully pulled out from under the fireplace. To
install the blower repeat the steps in the reverse order. There is a rubber
grommet at each end of the blower assembly which slides over the pins
supporting the blower. Make sure these grommets are in place when
reinstalling the blower.
Door Latch
Fuel Conversion
Converting the Ravelle™ 42 gas fireplace between natural gas and LP can
beaccomplishedbyeitherchangingthecassette(valveandpilotassembly)
or installing a conversion kit (regulator, burner orifice and changing the
orifice position on the pilot). Only a qualified service technician should
perform the conversion.
Cassette Removal:
Figure 49
1. Be sure the gas supply is shut off and the fireplace electrical supply
is shut off at the electrical panel before beginning the conversion.
Disconnect the gas supply from the fireplace, being careful not to
apply pressure to the valve in the process.
2. Remove the log set and brick panels (see Brick Panel and Log Set
Installation).
3. Remove the two allen head screws at the left and right rear of the
firebox securing the burner support. Lift out the burner and burner
support.
4. Remove the two allen head screws holding the burner in place.
5. Remove the labeled cover through which the valve control knobs
Glass/Door Maintenance
Cleaning: When cool, the glass may be cleaned with a clean, soft cloth
and a household glass cleaner. For cleaning white condensation from
the interior glass use a gas fireplace glass cleaner available from your
fireplace dealer. Use of caustic or abrasive cleaners may damage glass.
Gold or nickel plated doors must be cleaned with a household glass
cleaner or denatured alcohol and a soft cloth before firing or fingerprints
and stains will remain permanently. Never use abrasive polish to clean
the gold or nickel as it will ruin the finish. DO NOT operate fireplace with
broken glass. DO NOT clean door or glass when hot. DO NOT abuse glass
door by striking or slamming shut. DO NOT use substitute materials if
replacing glass. DO NOT spray commercial glass cleaner with ammonia
on the door and glass gasket as it may dissolve the gasket glue.
protrude by removing the two allen head screws
it and slide it off the valve knobs.
securing
6. Mark and disconnect wires on valve terminals #1 and #3 connected
to the burner on/off switch, thermostat, or remote control.
7. Remove all the allen head screws (around the perimeter ofthecassette
panel) fastening the cassette to the firebox.
8. Grasp the cassette assembly from inside the firebox and pull it into
the firebox and out of the fireplace.
9. Install new, converted, or serviced cassette in the reverse order of
removal. Replace gasket if necessary.
10.All parts and wires must be correctly reinstalled to ensure safe and
proper operation of the unit.
WARNING: Do not operate appliance with the glass panel re-
moved, cracked, or broken. Do not remove the glass door while
the fireplace is hot. Replacement of the glass door should be
done by a qualified service technician.
GlassReplacement: Theglassinthefireplacedoorcannotbereplaced
separately. Should the glass be damaged, the entire glass, gasket and
frame assembly should be replaced as a unit. This replacement glass as-
sembly is available from your Lennox Hearth Products dealer. The glass
is neo-ceramic and alternative types must not be used.
Conversion Kit:
Please see instructions provided with conversion kit.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in
the “ON” position.
IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting
should only be accomplished by a qualified service technician.
SYMPTOM
PROBABLE CAUSE
CORRECTIVE ACTION
Thin black coating (soot)
forms on the viewing
glass, logs, or firebox
Improper log or ember
placement
See Log Set Installation on Page 21. If there is soot in one specific location, the
rockwool below this location needs to be adjusted. This can be done by pulling embers
forward slightly. If the flames have soot tails, the shutter will need to be opened.
Improper air shutter
setting
If sooting continues open air shutter (see Air Shutter Adjustment on Page 31).
Not enough combus-
tion air
Check for debris obstructing air flow in valve compartment under fireplace or in front of
lower venting.
Humming or whistling
coming from fireplace.
Normal operating noise See Quiet Operation on Page 31. The noise may be reduced by slightly turning down the
flame. Turning the flame down will reduce the heat output of the fireplace.
Obstructed orifice
opening
If noise is excessive or is “whistling” have your gas supplier check the regulator and
orifices and replace if necessary.
A change in flame appear- A change in gas pres-
ance or burner operation. sure
Have your gas supplier check for correct gas pressure (7" W.C. / po. C.E. [1.74 kPa] natu-
ral gas; 11" W.C. / po. C.E. [2.74 kPa] LP gas). NOTE: NEVER BLOCK OR OBSTRUCT AIR
INTAKE OR OUTLET VENTS.
Improper log, ember or See Log Set Installation on Page 21.
volcanic stone place-
ment
Spark igniter will not light No gas supplied to unit Check gas supply. To purge, hold in gas cock on valve for 1-2 minutes and try again.
pilot after repeated tries.
or air in line
Defective igniter (no
spark at electrode)
Check for spark at electrode and pilot, if no spark and electrode wire is properly con-
nected, replace igniter and igniter wire.
Defective or misaligned Using a match, light pilot. If pilot lights, turn off pilot and trigger the igniter again. If pilot
electrode at pilot (spark lights, an intermittent gas/air supply may be the problem, if longer purge will not light
at electrode)
- check gap between electrode and pilot - should be 1/8 inch (3 mm) to have a strong
spark. If OK, replace pilot.
Pilot will not stay lit after
carefully following lighting
instructions.
Low gas inlet pressure
Defective thermopile
Check inlet pressure and adjust pilot if necessary.
Be sure wire connections from thermopile are tight at gas valve terminals.
Either rocker switch or thermostat wires may be grounded. Remove wires from valve
terminals. If pilot stays lit, trace switch wiring for a ground. May be grounded to fireplace
or gas supply.
Defective automatic
valve operator
Check open circuit millivolt output of thermopile. Reading should be greater than 325mV.
Also check thermopile wire for kinks that can cause loss of mV. Replace faulty thermopile
if wire is okay and reading is less than 325mV.
Turn valve knob to “ON” and thermostat (if installed) to 90º. Millivolt meter should read
greater than 100 mV. If reading is OK and burner does not turn on, replace gas valve
(qualified service technician only).
Main burner will not burn. Pilot has gone out
See Lighting Instructions.
Rocker switch, thermo- Disconnect rocker switch and thermostat wires at terminals 1 and 3 on valve. Jumper
stat, or wires defective
across from 1 to 3 with pilot lit. If burner comes on either rocker switch, thermostat, or
wiring is not functioning.
Thermopile may not be
generating sufficient
millivolts
Check thermopile with millivolt meter (see Maintenance and Servicing), recheck symp-
tom #2.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS - Ravelle™ 4ꢀ (RAVL4ꢀ)
Deluxe
Remote
Control
Wall
Thermostat
Contact an Authorized Lennox Hearth Products dealer to obtain any
of these parts. Never use substitute materials. Use of non-approved
parts can result in poor performance and safety hazards.
Controls
Part Number
Description
H4635
H0ꢀ51
DWTK
Wall Thermostat, Digital
RCL-STAT
Remote Control, RCL-STAT, Deluxe Thermo-
stat DC (ref. form #750129M)
H3134
Cassette Assembly, NG
(if LP, Also Requires 75064 Conversion Kit)
Burner Pan Assembly
Pilot Assembly (Convertible NG to LP)
Gas Control Valve NG
H6030
H5922
H5942
MASONRY TEMPLATES
(must be used if facing
material exceeds stove
body’s built-in 1” template)
(ref. form #775209M)
(if LP, also Requires H5945 Regulator Kit)
Regulator NG
Regulator LP
Main Burner Orifice #30 NG
Main Burner Orifice #49 LP
Blower W/Mounting Brackets
Blower Snap Switch
Blower Speed Control (rheostat)
On/Off Switch
On/Off Switch Wires
Piezo Igniter
Electrical Harness W/Inner Plate
Log Set
Bag of Embers / volcanic stone
Bag of Rockwool
H5943
H5945
H5928
H5929
H3121
H5875
H5742
H5744
H3119
H5745
H3120
H5859
H5863
H5864
H3101
H3123
Cat. No.
Model
Description
75098
75101
75035
H7ꢀ01
MT-ARCH4ꢀ
Arched Template
MT-CLS4ꢀ
Classic Template
Foundry™ Template
Screen Template
MT-FOUNDRY4ꢀ
MT-SCREEN4ꢀ
Misc.
Nail Plates (4 x 1ꢀ) galvanized
75ꢀ59
NP-RAVL30/4ꢀ
Firebox Door W/Glass
Flue Restrictor Plates W/Hardware
75ꢀ47
75134
75ꢀ60
Reducer 8”-6 5/8” Reducer (8” to 6-5/8”)
RAVL4ꢀ-DUCTKT Ductability Kit (ref. form #775272M)
RAVL4ꢀ-DHHS,
Dog House Heat Shield (for remote thermo-
stat) (ref. form #775207M)
ACCESSORIES
Knobs
75169
75170
75010
Gold (set of ꢀ)
Brushed Nickel (set of ꢀ)
Black Nickel (set of ꢀ)
Brick Panel Kits (ref. form #775269M)
Standard Tan Brick
Red Brick
Architectural Stone
Gas Conversion Kits
Cat. No.
75353
Model
Description
RAVL4ꢀ-STD-BRK
RAVL4ꢀ-ARCHSTONE
RAVL4ꢀ-RED-BRK
Standard Tan Brick
Architectural Stone
Red Brick
75095
75064
RAVL4ꢀ-CK-LP to NG Conversion Kit LP to NG (ref. form #775241M)
75354
RAVL4ꢀ-CK-NG to LP Conversion Kit NG to LP (ref. form #775250M)
75356
NOTE: The form numbers referenced are the part numbers of the instruction
sheets included in kits.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Face Kits
Classic
Required to
Face Kits
Arched
(ref. form #775253M)
Complete Face: Insets
(ref. form #775253M)
Cat. No.
75ꢀ94
75ꢀ96
75ꢀ95
75ꢀ97
Model
Description
Cat. No.
75ꢀ90
75ꢀ9ꢀ
75ꢀ91
75ꢀ93
Model
Description
AIF4ꢀ-BLK
AIF4ꢀ-GOLD
AIF4ꢀ-NKL
AIF4ꢀ-BKNKL
Black Face, Arched
CIF4ꢀ-BLK
CIF4ꢀ-GOLD
CIF4ꢀ-NKL
Black Face, Classic
Gold Face, Arched
Gold Face, Classic
Brushed Nickel Face, Arched
Black Nickel Face, Arched
Brushed Nickel Face, Classic
Black Nickel Face, Classic
CIF4ꢀ-BKNKL
INSETS (Required -
Includes 1 Top and
1 Bottom Inset)
Insets
(ref. form #775253M)
(ref. form #775253M)
753ꢀꢀ
753ꢀ4
753ꢀ3
753ꢀ5
75338
75340
75339
75341
75314
75316
75315
75317
AI4ꢀ-ASPEN-BLK
AI4ꢀ-ASPEN-GOLD
AI4ꢀ-ASPEN-BRNKL
AI4ꢀ-ASPEN-BKNKL
AI4ꢀ-NAPA-BLK
ASPEN Black
753ꢀ6
753ꢀ8
753ꢀ7
753ꢀ9
75318
753ꢀ0
75319
753ꢀ1
7534ꢀ
75344
75343
75345
CI4ꢀ-ASPEN-BLK
ASPEN Black
ASPEN Gold
CI4ꢀ-ASPEN-GOLD
CI4ꢀ-ASPEN-BRNKL
CI4ꢀ-ASPEN-BKNKL
CI4ꢀ-NAPA-BLK
ASPEN Gold
ASPEN Brushed Nickel
ASPEN Black Nickel
NAPA Black
ASPEN Brushed Nickel
ASPEN Black Nickel
NAPA Black
AI4ꢀ-NAPA-GOLD
AI4ꢀ-NAPA-BRNKL
AI4ꢀ-NAPA-BKNKL
AI4ꢀ-TUSCAN-BLK
NAPA Gold
CI4ꢀ-NAPA-GOLD
CI4ꢀ-NAPA-BRNKL
CI4ꢀ-NAPA-BKNKL
CI4ꢀ-TUSCAN-BLK
CI4ꢀ-TUSCAN-GOLD
NAPA Gold
NAPA Brushed Nickel
NAPA Black Nickel
TUSCAN Black
NAPA Brushed Nickel
NAPA Black Nickel
TUSCAN Black
TUSCAN Gold
AI4ꢀ-TUSCAN-GOLD TUSCAN Gold
AI4ꢀ-TUSCAN-BRNKL TUSCAN Brushed Nickel
AI4ꢀ-TUSCAN-BKNKL TUSCAN Black Nickel
CI4ꢀ-TUSCAN-BRNKL TUSCAN Brushed Nickel
CI4ꢀ-TUSCAN-BKNKL TUSCAN Black Nickel
Foundry™
Face Kit
Screen Kit
(ref. form #775289M)
(ref. form #775286M)
750ꢀ9
Screen Face/double Door/black, 43-1/4”W x 31-7/8”H
751ꢀ4
FOUNDRYF-4ꢀ BLACK FACE/Black Nickel Hand-Hammered
Straps
Barrier Screen Kit
(ref. form # 506033-23)
H77ꢀ3
RAV4ꢀ-BS
Barrier Screen Kit
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY / LISTING LABEL - ENGLISH
SAFETY / LISTING LABEL - FRENCH
MODEL
MODÈLE
SERIAL
NO.
MODEL
MODÈLE
SERIAL
NO.
RAVELLE™ 42
Le numéro de série est indiqué dans
la section anglophone de cette étiquette
Portland
RAVL42
RAVELLE™ 42
Portland
US
US
MANUFACTURED BY / FABRIQUÉ PAR:
LENNOX HEARTH PRODUCTS
MANUFACTURED BY / FABRIQUÉ PAR:
LENNOX HEARTH PRODUCTS
PO BOX 987
Report No. / Número de Rapport
050-S-08c-5
PO BOX 987
AUBURN, WA., USA 98071
Report No. / Número de Rapport
050-S-08c-5
AUBURN, WA., USA 98071
CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT CETTE
ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.
FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.
CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT CETTE
ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.
HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU GAZ - INSERTION DE FOYER AU GAZ - NE PAS UTILISER
AVEC DU COMBUSTIBLE SOLIDE
LISTED VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL
TESTED TO ANSI Z21.88-2005/CSA 2.33-2005 “VENTED GAS FIREPLACE HEATERS”, UL307b, CSA P.4.1-02, AND CGA 2.17-M91.
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, FOLLOW THE CURRENT ANSI Z223.1/NFPA
54-LATEST EDITION (USA) OR CAN/CGA B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER’S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES ONLY - MASONRY
OR FACTORY BUILT. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN
AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE OWNER’S
MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED. MAY BE
INSTALLED IN RESIDENTIAL BEDROOMS.
TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», UL307B, CSA P.4.1-02, ET CGA 2.17-M91.
CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI
NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA). CET APPAREIL DOIT ÊTRE INSTALLÉ
SELON LES DIRECTIVES D’INSTALLATION DU FABRICANT. POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE SOLIDE SEULEMENT
- DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE. CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS CONÇU POUR ÊTRE UTILISÉ
AVEC DES FILTRES À AIR. CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE ET PEUT
ÊTRE INSTALLÉ DANS UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE PERMETTENT.
VOIR LE MANUEL D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES
TYPES DE GAZ À MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT,
FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST EDITION (CANADA).
DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.
SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE CONFORMES
AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.
MINIMUM CLEARANCES TO COMBUSTIBLES IN INCHES
DÉGAGEMENTS AUX COMBUSTIBLES - EN POUCES (MILLIMÈTRES)
Front corners to enclosure (from stand-offs)
Back to enclosure (from stand-offs)
Top to header (from stand-offs)
Bottom of unit to floor
0
0
0
Hearth Extension - not required but recommended
Rear corners to enclosure (from stand-offs)
Base of unit to mantel
Coins avant au caisson (depuis les espaceurs) 0 (0mm) Extension d’âtre - Prolongement de l'âtre - Non requis mais recommandé
0
Du dos au caisson (depuis les espaceurs)
Du dessus au support (depuis les espaceurs) 0 (0mm) De la base de l’unité au manteau - 47-5/8"" (1210mm)
Du fond de l’unité au plancher 0 (0mm) De la base de l’unité à la finition/ façade du dessus - 41-5/8" (1057mm)
0 (0mm) Côtés arrière au caisson (depuis les espaceurs) - 0 (0mm)
47-5/8
41-5/8
0
Base of unit to top trim/facing
Side trim or wall to edge of door glass
7.5
De la finition du côté ou du mur au bord de la vitre 7-1/2 (191mm)
See owner’s manual for additional clearance information on mantels and direct vent pipe.
Voir le manuel d’installation pour plus d’informations sur les dégagements requis au manteau, conduits direct-vent et prolongement de
l’’âtre.
NG
LP
NG
5
3.5
1.7
LP
11
10
Input Rate on “HI” (BTU/H)
Input Rate on “LO” (BTU/H)
Orifice Size (DMS)
42,000
29,500
#30
36,000
25,000
#49
Minimum Inlet Pressure (in. WC)
Manifold Pressure on “HI” (in. WC)
Manifold Pressure on “LO” (in. WC)
SPÉCIFICATIONS
NG
LP
NG
5
3.5
1.7
LP
11
10
5.1
Entrée Max/min BTU/hr 0-4500 Pi (0-1370 M)* 42,000 36,000 Pression Minimum D’entrée Du Gaz (IN. WC/C.E.)
Entrée Minimum BTU/hr 0-4500 Pi (0-1370 M)* 29,500 25,000 Pression À La Sortie - HI (IN. WC/C.E.)
Blower Electrical Rating: 120 VAC, 60 Hz, Less Than 2 Amps
*Unit factory equipped for 0-2000 ft/0-610 m, in Canada 0-4500 ft/0-1370 M. For altitudes above 2,000 ft/610m (in Canada 4500 ft/1370m) de-rate
the appliance by four (4)% for every 1,000 ft (405 m).
Orifice (DMS)*
#30
#49
Pression À La Sortie - LO (IN. WC/C.E.)
5.1
Spécifications Électrique 120 Vca, 60 Hz, Moins De 2 Ampères
See owner’s manual for instructions on changing cassette/valve assembly.
*En altitude, au-delà de 2000 pi/610 m, (au canada 0-4500 pi/0-1370m) la capacité énergétique de l’appareil diminue de quatre (4)% pour chaque
1000 pi (405 m).
Référez-vous au manuel d'instructions du propriétaire pour changer le bloc d'assemblage de la valve.
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP
CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY.
KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING INSTRUCTIONS
ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY. DO NOT
OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S)
SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
DANGER:
CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES
ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS LA PIÈCE.
GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES
INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT TEMPS. VOIR LES MANUELS
D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. SEUL LE PANNEAU VITRÉ FOURNI PAR LE MANUFACTURIER
PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. EN AUCUN CAS, L’APPAREIL NE PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE
BRISÉE. LE REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE
INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS
APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE
AGENCY OR GAS SUPPLIER.
AVERTISSEMENT: UNE INSTALLATION INADÉQUATE DE MÊME QU’UN AJUSTEMENT, UNE MODIFICATION, UNE RÉPARATION OU UN
ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. RÉFÉREZ-VOUS AU MANUEL
D’ENTRETIEN LIVRÉ AVEC CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE
DE SERVICE OU UN FOURNISSEUR DE GAZ.
DATE OF MANUFACTURE
ꢀ009 ꢀ010 ꢀ011 ꢀ01ꢀ
FEB
APR MAY JUN
JUL AUG SEP
OCT NOV DEC
JAN
MAR
Le date de fabrication est indiquée dans la section anglophone de cette étiquette
Part No./ No. pièce #36202 Rev. A, 06/2007
DO NOT REMOVE OR COVER THIS LABEL
IGN
No. pièce #36264 Rev. A, 06/2007
N’ENLEVEZ PAS OU NE COUVREZ PAS CETTE ÉTIQUETTE
IGN 07-2554
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
LIGHTING LABEL - ENGLISH
LIGHTING LABEL - FRENCH
POUR VOTRE SÉCURITÉ, LIRE AVANT L’ALLUMAGE
FOR YOUR SAFETY READ BEFORE OPERATING
AVERTISSEMENT: SI VOUS NE RESPECTEZ PAS RIGOUREUSEMENT LES INSTRUCTIONS CI-DESSOUS, VOUS POURRIEZ ENCOURIR UN RISQUE D’INCENDIE ET/OU D’EXPLOSION
QUI POURRAIENT CAUSER DES DOMMANGES MATÉRIELS ET CORPORELS POUVANT ENTRAÎNER LA MORT.
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
DANGER: CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX.
GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES INFLAMMABLES.
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, FURNITURE, GASOLINE AND OTHER LIQUIDS WITH
FLAMMABLE VAPORS AWAY. NEVER OPERATE UNIT WITH GLASS DOOR OFF OR ATTEMPT TO OPEN THE DOOR WHILE HOT.
A. Cet appareil utilise un système d’allumage par étincelle (allumeur Piézo-électrique) pour allumer la veilleuse. Assurez-vous de suivre
rigoureusement les instructions d’allumage de la veilleuse.
A. This appliance is equipped with a piezo ignition device to light the pilot. When lighting the pilot, follow these instructions exactly.
B. AVANT D’ALLUMER L’APPAREIL, assurez-vous qu’il n’y
a
pas d’odeur de gaz près de l’appareil ni près du sol car certains gaz plus
B. BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air
and will settle on the floor.
lourds que l’air auraient tendance à s’y accumuler en cas de fuite.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
•
•
•
•
N’ALLUMEZ aucun appareil.
WHAT TO DO IF YOU SMELL GAS:
Ne touchez aucune prise électrique; N’utilisez aucun téléphone dans votre édifice.
•
•
•
•
DO NOT try to light the appliance.
Sortez de la maison. À partir d’un autre endroit, appelez immédiatement votre fournisseur de gaz et suivez les directives.
S’il est impossible de joindre le distributeur du gaz, appelez les pompiers.
DO NOT touch any electric switch; do not use any phone in the building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
C. N’utilisez aucun outil pour tourner ou pousser le dispositif de contrôle du gaz. Si vous ne pouvez le faire manuellement, n’essayez
pas de réparer l’appareil. Appelez un technicien de service qualifié. Si vous tentez de forcer ou réparer le dispositif de contrôle du gaz
vous pourriez encourir un risque d’incendie et/ou d’explosion.
C. Use only your hand to push in or turn the gas control knob. Never use any tool. If the knob will not push in or turn by hand, don't try
to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. N’utilisez pas cet appareil si une de ses composantes
a
été émergée dans l’eau. Appelez immédiatement un technicien de service
qualifié et reconnu afin qu’il inspecte et remplace au besoin toutes pièces du système qui auraient été en contact avec l’eau.
D. DO NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control which has been under water.
ALLUMAGE
DANGER: VOTRE APPAREIL AU GAZ LENNOX DOIT ÊTRE OPÉRÉ AVEC DES PORTES DE VERRE.
ATTENTION! Lisez les consignes de sécurité ci-dessous avant d’opérer votre appareil.
1. Ouvrir la porte du bas. Assurez-vous que l’alimentation en gaz est à la position Fermée
“OFF”. Si l’appareil est équippé d’un thermostat, placez-le à la température la plus basse.
2. Couper le courant électrique qui alimente l’appareil.
SIT Millivolt Gas Valve
OPERATING INSTRUCTIONS
CAUTION: YOUR LENNOX™ GAS APPLIANCE MUST ALWAYS BE OPERATED WITH GLASS DOOR IN PLACE.
STOP! Read the safety information above before proceeding.
SIT Millivolt Gas Valve
3. Enfoncez légèrement le bouton de contrôle du gaz et tournez-le dans le sens des aiguilles
FlameHeightControl
Knob(HI/LO)
GasControlKnob
(Pilot/On/Off)
1. Open the lower access door. Make sure gas supply shut-off cocks are open and ON/OFF
d’une montre
à la position “OFF”.
Rocker Switch is “OFF”. If equipped with a thermostat, set it to the lowest setting.
2. Turn off all electrical power to the appliance.
NOTE: Le bouton de contrôle du gaz ne peut être tourné de la position “PILOT” à “OFF”
sans qu’une légère pression ne soit appliquée.
Interrupteur
3. Push in Gas Control Knob slightly and turn clockwise
to “OFF”.
4. Attendez au moins 5 minutes pour que le gaz qui se trouve dans la chambre de combustion
puissse s’échapper. Si vous sentez une odeur de gaz ARRÊTEZ! Référez-vous à la section B
ci-dessus. Si vous ne sentez pas d’odeur de gaz, allez à la prochaine étape.
5. Vous pouvez aussi voir le pilote en regardent à travers le V situer dans le bas de la bûche gauche
avant. Une flamme bleue est visible lorsque le veilleuse est allumée.
Allumeur
Veilleuse à gaz
Thermopile
NOTE: Knob cannot be turned from “PILOT” to “OFF” unless Knob is pushed in slightly. Do
not force.
4. Wait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” above. If you
don’t smell gas continue.
MillivoltPilot
Allumeur
GasControlKnob
(Pilot/On/Off)
FlameHeightControlKnob
(HI/LO)
Thermocouple
6. Tournez le bouton de contrôle de gaz dans le sens inverse des aiguilles d’une montre
pour le placer sur “PILOT”.
7. Cet appareil de chauffage est equipé d’un système d’allumage par étincelle (allumeur Piézo-
électirque), devant être utilisé pour l’allumage de la veilleuse. Poussez complètement le bouton de contrôle du gaz et le
maintenir dans cette position. Appuyez immédiatement sur le bouton (allumeur Piézo-électrique) situé à gauche du robinet
de contrôle du gaz.L’étincelle produite par l’allumeur Piézo-électrique doit allumer la veilleuse. Continuez à maintenir le
bouton de contrôle dans cette position pendant environ 30 secondes après l’allumage de la veilleuse. Relâchez le bouton
de contrôle du gaz qui reviendra à la position initiale. La veilleuse doit rester allumée. Répétez les étapes 4 à 8 pendant 15
secondes supplémentaires si la veilleuse s’éteind.
•`Si le bouton de contrôle du gaz ne revient pas à la position initiale une fois relâché, appeler immédiatement un technicien
qualifié ou votre distributeur de gaz.
•`Si la veileuse ne reste pas allumée après plusieurs essais, tournez le bouton de contrôle du gaz à la position “OFF” et
appelez immédiatement un technicien qualifié ou votre distributeur de gaz.
PiezoIgniter
5. Locate the pilot by looking through the “V” in the left front lower log. Blue flame will be seen when the
pilot is lit.
ON/OFFSwitch
6. Turn the gas control knob counterclockwise
to the “PILOT” position.
7. Push the knob all the way in and hold in that position. Immediately light the pilot by pressing the ignitor
button several times until pilot is lit. Continue to hold the knob in for about 30 seconds after the pilot is
lit. Release knob and it will pop back out.
Pilot should remain lit. If it goes out, repeat steps 4-8 holding knob in an additional 15 seconds after pilot
is lit.
If knob does not pop out when released, stop and immediately call your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service
technician or your gas supplier.
Gas Pilot Hood
Thermopile
Igniter (electrode)
Thermocouple
•
•
8. After pilot is lit, turn gas control counterclockwise
knob has popped out.
to “ON”. Knob can only be turned “ON” if the
MILLIVOLT PILOT
8. Lorsque la veilleuse est allumée, tournez le bouton de contrôle du gaz dans le sens invers des aiguilles d’une montre
pour le placer à la position “ON”. Le bouton de contrôle peut-être tourné à la position “ON” seulement si il n’est plus enfoncé.
9. Pour allumer le brûleur, mettre l’interrupteur à la position “ON” ou ajustez le thermostat à la température souhaitée.
10. Ajustez la flamme et la température souhaitée en tournant le bouton de réglage de la flamme dans les sens des aiguille
9. To turn burner on, turn “ON/OFF” rocker switch to “ON” or set the thermostat to the desired temperature above room temperature.
10. Adjust the flame height (and heat output) by turning the flame height knob clockwise
for full flame.
for reduced flame and counterclockwise
d’une montre
pour l’abaisser et dans le sens contraire
pour l’augmenter.
11. Ajustez le ventilateur au volume désiré lorsque l’appareil aura atteint la température de fonctionnement.
11. Set the blower to the desired air flow after it turns on when the appliance reaches operating temperature.
POUR COUPER L’ALIMENTATION EN GAZ DE L’APPAREIL
TO TURN OFF GAS TO APPLIANCE
1. Turn off the “ON/OFF” rocker switch and/or thermostat (if installed).
1. Fermez l’interrupteur et/ou le thermostat «MARCHE/ARRÊT».
2. Coupez l’alimentation électrique de l’appareil si vous prévoyez en faire le service.
3. Tournez le bouton de commande du gaz dans le sens des aiguilles d’une montre
à “OFF”. Ne le forcez pas.
2. Turn off electric power to the appliance if service is to be performed.
Cet appareil a besoin d’air frais pour opérer sécritairement et doit être installé pour qu’il y ait un apport en air suffisant. Référez-vous aux
manuels d’entretien et d’installation fournis avec l’appareil.
3. Turn gas control knob clockwise
to "OFF". Do not force.
AVERTISSEMENT: Une installation inadéquate, un mauvais ajustement, une altération ou toutes autres modifications
inappropriés pourraient entraîner des blessures physiques et/ou des dommanges matériels. Référez-vous au guide
d’utilisation fourni avec ce foyer. Pour assistance ou information supplémentaires contactez un installateur qualifié, un agent
de service ou un fournisseur de gaz.
This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate
combustion and ventilation air. See Installation and Operation Manual accompanying appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. For assistance or additional information, consult a
qualified installer, service agency or your gas supplier.
Operation of this appliance when not connected to a properly installed and maintained venting system can result
in carbon monoxide (CO) poisoning and possible death.
Si vous opérez cet appareil sans qu’il ne soit correctement raccordé à un conduit d’évacuation, vous pourriez risquer d’être empoisonné au
monoxyde de carbone (CO) ce qui pourrait entraîner des conséquences grave ou la mort.
PROCÉDURE D’ARRÊT
1. Pour arrêter le brûleur, mettre l’interrupteur à la position “OFF” ou ajustez le thermostat à une température en dessous de
la température ambiante. La veilleuse restera allumée pour permettre un alummage ultérieur.
Pour un arrêt complet: Consultez la procédure ci-dessus «POUR COUPER L’ALIMENTATION EN GAZ DE L’APPAREIL».
SHUTDOWN PROCEDURE
1. To turn off the burner, switch the rocker switch to “OFF” or adjust the thermostat to a setting below room temperature
(if installed). The pilot will remain lit for future burner ignition.
No. pièce#36264 Rev. A, 06/2007
IGN 07-2554
IGN
#36202 Rev. A, 06/2007
For complete shutdown: See “TO TURN OFF GAS TO APPLIANCE” above.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Normally, all parts should be ordered through your Lennox distributor or
dealer. Parts will be shipped at prevailing prices at time of order.
WARRANTY
Your gas fireplace is covered by a limited warranty (provided with
appliance). Please read the warranty to be familiar with its coverage.
When ordering repair parts, always give the following information:
1. The model number of the appliance.
ꢀ. The serial number of the appliance.
3. The part number.
Retain this manual. File it with your other documents for future refer-
ence.
4. The description of the part.
5. The quantity required.
PRODUCT REFERENCE INFORMATION
6. The installation date of the appliance.
We recommend that you record the following important information
aboutyourappliance. PleasecontactyourLennoxHearthProductsdealer
for any questions or concerns. For the number of your nearest Lennox
Hearth Products dealer, please call 1-800-9-LENNOX.
If you encounter any problems or have any questions concerning the
installation or application of this system, please contact your dealer.
LENNOX HEARTH PRODUCTS
1110 West Taft Avenue
Orange, CA 9ꢀ865
REPLACEMENT PARTS
See Page 36 for a complete replacement parts list. Use only parts sup-
plied from the manufacturer.
Your Fireplace's Model Number________________________________________
Your Fireplace’s Serial Number ________________________________________
The Date On Which Your Fireplace Was Installed___________________________
Your Dealer's Name _________________________________________________
Fuel Type (Check one)
c
Natural Gas
c
Propane Gas (LP)
Lennox Hearth Products reserves the right to make changes at any time, without notice, in
design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
Printed in U.S.A. © ꢀ007 Lennox Hearth Products
P/N 775,ꢀ19M REV. C 06/ꢀ009
1110 West Taft Avenue • Orange, CA 9ꢀ865