Miller Electric Welder I 22A I 24A User Manual

OM-186 895G  
June 1999  
Processes  
MIG (GMAW) Welding  
Flux Cored (FCAW) Welding  
Description  
Wire Feeder  
I-22A & I-24A  
Visit our website at  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . .  
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 1 CONSIGNES DE SECURITE LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .  
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
1
1
3
3
4
5
5
5
WARNING  
This product, when used  
for welding or cutting,  
produces fumes or  
gases which contain  
chemicals known to the  
State of California to  
cause birth defects and,  
in some cases, cancer.  
(California Health &  
Safety Code Section  
25249.5 et seq.)  
1-3 Dangers supplémentaires en relation avec l’installation, le fonctionnement  
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7
8
8
9
9
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 2 DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-1. Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-2. Rating Label For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-3. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
10  
10  
SECTION 3 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-2. Site Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-3. Gun Recommendation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-4. Equipment Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-5. 14-Pin Receptacle, Shielding Gas And Optional Volt Sense Lead . . . . . . . . . . . . . . . . . . . . . .  
3-6. 14-Pin Receptacle Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-7. Connecting Welding Gun And Weld Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-8. Optional Meter Circuit Board Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-9. Motor Start/Burnback Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-10.Installing Wire Guide And Drive Roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-11.Installing And Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
11  
11  
12  
12  
12  
13  
13  
14  
15  
16  
17  
SECTION 4 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
4-1. Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-2. Optional Side Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
18  
19  
SECTION 5 MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5-2. Overload Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
19  
20  
20  
SECTION 6 ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
SECTION 7 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
OPTIONS AND ACCESSORIES  
WARRANTY  
OM-186 895  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Declaration of Conformity for  
European Community (CE) Products  
This information is provided for units with CE certification (see rating label on unit).  
NOTE  
Manufacturer’s Name:  
Miller Electric Mfg. Co.  
1635 W. Spencer Street  
Appleton, WI 54914 USA  
Manufacturer’s Address:  
Declares that the product:  
I-22A And I-24A  
conforms to the following Directives and Standards:  
Directives  
Low Voltage Directive: 73/23/EEC  
Electromagnetic Compatibility (EMC) Directive: 89/336/EEC  
Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC  
Standards  
Arc Welding Equipment Part I: Welding Power Sources: IEC 974-1  
(April 1995 Draft Revision)  
Arc Welding Equipment: Wirefeed Systems: IEC 974-4  
(May 1995 Draft Revision)  
Degrees of Protection Provided By Enclosures (IP Code): IEC 529:1989  
Insulation Coordination For Equipment With Low-Voltage Systems:  
Part I: Principles, Requirements and Tests: IEC 664-1: 1992  
Electromagnetic Compatibility, (EMC): EN 50199  
European Contact:  
Mr. Luigi Vacchini, Managing Director  
MILLER Europe S.P.A.  
Via Privata Iseo  
20098 San Giuliano  
Milanese, Italy  
Telephone:  
Fax:  
39(02)98290-1  
39(02)98281-552  
dec_con1 1/96  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING  
som _nd_5/97  
1-1. Symbol Usage  
Means Warning! Watch Out! There are possible hazards  
with this procedure! The possible hazards are shown in  
the adjoining symbols.  
This group of symbols means Warning! Watch Out! possible  
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.  
Consult symbols and related instructions below for necessary actions  
to avoid the hazards.  
Y
Marks a special safety message.  
. Means “Note”; not safety related.  
1-2. Arc Welding Hazards  
Y
The symbols shown below are used throughout this manual to  
call attention to and identify possible hazards. When you see  
the symbol, watch out, and follow the related instructions to  
avoid the hazard. The safety information given below is only  
a summary of the more complete safety information found in  
the Safety Standards listed in Section 1-4. Read and follow all  
Safety Standards.  
D
D
D
If earth grounding of the workpiece is required, ground it directly  
with a separate cable do not use work clamp or work cable.  
Do not touch electrode if you are in contact with the work, ground,  
or another electrode from a different machine.  
Use only well-maintained equipment. Repair or replace damaged  
parts at once. Maintain unit according to manual.  
D
D
D
Wear a safety harness if working above floor level.  
Keep all panels and covers securely in place.  
Y
Y
Only qualified persons should install, operate, maintain, and  
repair this unit.  
During operation, keep everybody, especially children, away.  
Clamp work cable with good metal-to-metal contact to workpiece  
or worktable as near the weld as practical.  
D
D
Insulate work clamp when not connected to workpiece to prevent  
contact with any metal object.  
ELECTRIC SHOCK can kill.  
Do not connect more than one electrode or work cable to any  
single weld output terminal.  
Touching live electrical parts can cause fatal shocks  
or severe burns. The electrode and work circuit is  
electrically live whenever the output is on. The input  
power circuit and machine internal circuits are also  
SIGNIFICANT DC VOLTAGE exists after removal of  
input power on inverters.  
live when power is on. In semiautomatic or automatic wire welding, the  
wire, wire reel, drive roll housing, and all metal parts touching the  
welding wire are electrically live. Incorrectly installed or improperly  
groundedequipment is a hazard.  
D
Turn Off inverter, disconnect input power, and discharge input  
capacitors according to instructions in Maintenance Section  
before touching any parts.  
D
D
D
Do not touch live electrical parts.  
Wear dry, hole-free insulating gloves and body protection.  
FUMES AND GASES can be hazardous.  
Insulate yourself from work and ground using dry insulating mats  
or covers big enough to prevent any physical contact with the work  
or ground.  
Welding produces fumes and gases. Breathing  
these fumes and gases can be hazardous to your  
health.  
D
Do not use AC output in damp areas, if movement is confined, or if  
there is a danger of falling.  
D
D
Keep your head out of the fumes. Do not breathe the fumes.  
D
D
Use AC output ONLY if required for the welding process.  
If inside, ventilate the area and/or use exhaust at the arc to remove  
welding fumes and gases.  
If AC output is required, use remote output control if present on  
unit.  
D
D
If ventilation is poor, use an approved air-supplied respirator.  
D
Disconnect input power or stop engine before installing or  
servicing this equipment. Lockout/tagout input power according to  
OSHA 29 CFR 1910.147 (see Safety Standards).  
Read the Material Safety Data Sheets (MSDSs) and the  
manufacturer’s instructions for metals, consumables, coatings,  
cleaners, and degreasers.  
D
D
Properly install and ground this equipment according to its  
Owner’s Manual and national, state, and local codes.  
D
Work in a confined space only if it is well ventilated, or while  
wearing an air-supplied respirator. Always have a trained watch-  
person nearby. Welding fumes and gases can displace air and  
lower the oxygen level causing injury or death. Be sure the breath-  
ing air is safe.  
Always verify the supply ground check and be sure that input  
power cord ground wire is properly connected to ground terminal in  
disconnect box or that cord plug is connected to a properly  
groundedreceptacle outlet.  
D
D
Do not weld in locations near degreasing, cleaning, or spraying op-  
erations. The heat and rays of the arc can react with vapors to form  
highly toxic and irritating gases.  
D
D
When making input connections, attach proper grounding conduc-  
tor first double-check connections.  
Frequently inspect input power cord for damage or bare wiring −  
replace cord immediately if damaged bare wiring can kill.  
Do not weld on coated metals, such as galvanized, lead, or  
cadmiumplated steel, unless the coating is removed from the weld  
area, the area is well ventilated, and if necessary, while wearing an  
air-suppliedrespirator. The coatings and any metals containing  
these elements can give off toxic fumes if welded.  
D
D
D
Turn off all equipment when not in use.  
Do not use worn, damaged, undersized, or poorly spliced cables.  
Do not drape cables over your body.  
OM-186 895 Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ARC RAYS can burn eyes and skin.  
BUILDUP OF GAS can injure or kill.  
D
D
Shut off shielding gas supply when not in use.  
Always ventilate confined spaces or use  
approved air-supplied respirator.  
Arc rays from the welding process produce intense  
visible and invisible (ultraviolet and infrared) rays  
that can burn eyes and skin. Sparks fly off from the  
weld.  
D
Wear a welding helmet fitted with a proper shade of filter to protect  
your face and eyes when welding or watching (see ANSI Z49.1  
and Z87.1 listed in Safety Standards).  
HOT PARTS can cause severe burns.  
D
D
D
Wear approved safety glasses with side shields under your  
helmet.  
D
D
Do not touch hot parts bare handed.  
Allow cooling period before working on gun or  
torch.  
Use protective screens or barriers to protect others from flash and  
glare; warn others not to watch the arc.  
Wear protective clothing made from durable, flame-resistant mate-  
rial (leather and wool) and foot protection.  
MAGNETIC FIELDS can affect pacemakers.  
WELDING can cause fire or explosion.  
D
D
Pacemaker wearers keep away.  
Wearers should consult their doctor before  
going near arc welding, gouging, or spot  
welding operations.  
Welding on closed containers, such as tanks,  
drums, or pipes, can cause them to blow up. Sparks  
can fly off from the welding arc. The flying sparks, hot  
workpiece, and hot equipment can cause fires and  
burns. Accidental contact of electrode to metal objects can cause  
sparks, explosion, overheating, or fire. Check and be sure the area is  
safe before doing any welding.  
NOISE can damage hearing.  
D
D
D
Protect yourself and others from flying sparks and hot metal.  
Do not weld where flying sparks can strike flammable material.  
Noise from some processes or equipment can  
damagehearing.  
Remove all flammables within 35 ft (10.7 m) of the welding arc. If  
this is not possible, tightly cover them with approved covers.  
D
Wear approved ear protection if noise level is  
high.  
D
Be alert that welding sparks and hot materials from welding can  
easily go through small cracks and openings to adjacent areas.  
D
D
Watch for fire, and keep a fire extinguisher nearby.  
CYLINDERS can explode if damaged.  
Be aware that welding on a ceiling, floor, bulkhead, or partition can  
cause fire on the hidden side.  
Shielding gas cylinders contain gas under high  
pressure. If damaged, a cylinder can explode. Since  
gas cylinders are normally part of the welding  
process, be sure to treat them carefully.  
D
D
Do not weld on closed containers such as tanks, drums, or pipes,  
unless they are properly prepared according to AWS F4.1 (see  
Safety Standards).  
Connect work cable to the work as close to the welding area as  
practical to prevent welding current from traveling long, possibly  
unknown paths and causing electric shock and fire hazards.  
D
D
Protect compressed gas cylinders from excessive heat, mechani-  
cal shocks, slag, open flames, sparks, and arcs.  
Install cylinders in an upright position by securing to a stationary  
support or cylinder rack to prevent falling or tipping.  
D
D
Do not use welder to thaw frozen pipes.  
Remove stick electrode from holder or cut off welding wire at  
contact tip when not in use.  
D
D
D
D
D
Keep cylinders away from any welding or other electrical circuits.  
Never drape a welding torch over a gas cylinder.  
D
D
Wear oil-free protective garments such as leather gloves, heavy  
shirt, cuffless trousers, high shoes, and a cap.  
Never allow a welding electrode to touch any cylinder.  
Never weld on a pressurized cylinder explosion will result.  
Remove any combustibles, such as a butane lighter or matches,  
from your person before doing any welding.  
Use only correct shielding gas cylinders, regulators, hoses, and fit-  
tings designed for the specific application; maintain them and  
associated parts in good condition.  
FLYING METAL can injure eyes.  
D
D
Turn face away from valve outlet when opening cylinder valve.  
D
Welding, chipping, wire brushing, and grinding  
cause sparks and flying metal. As welds cool,  
they can throw off slag.  
Keep protective cap in place over valve except when cylinder is in  
use or connected for use.  
D
Read and follow instructions on compressed gas cylinders,  
associated equipment, and CGA publication P-1 listed in Safety  
Standards.  
D
Wear approved safety glasses with side  
shields even under your welding helmet.  
OM-186 895 Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3. Additional Symbols For Installation, Operation, And Maintenance  
FIRE OR EXPLOSION hazard.  
MOVING PARTS can cause injury.  
D
Do not install or place unit on, over, or near  
combustiblesurfaces.  
Do not install unit near flammables.  
D
D
Keep away from moving parts such as fans.  
Keep all doors, panels, covers, and guards  
closed and securely in place.  
D
D
Do not overload building wiring be sure power supply system is  
properly sized, rated, and protected to handle this unit.  
FALLING UNIT can cause injury.  
H.F. RADIATION can cause interference.  
D
D
D
Use lifting eye to lift unit only, NOT running  
gear, gas cylinders, or any other accessories.  
Use equipment of adequate capacity to lift and  
support unit.  
If using lift forks to move unit, be sure forks are  
long enough to extend beyond opposite side of  
unit.  
D
High-frequency (H.F.) can interfere with radio  
navigation, safety services, computers, and  
communicationsequipment.  
D
Have only qualified persons familiar with  
electronic equipment perform this installation.  
D
D
The user is responsible for having a qualified electrician prompt-  
ly correct any interference problem resulting from the installa-  
tion.  
If notified by the FCC about interference, stop using the  
equipmentat once.  
OVERUSE can cause OVERHEATING  
D
D
Allow cooling period; follow rated duty cycle.  
Reduce current or reduce duty cycle before  
starting to weld again.  
D
D
Have the installation regularly checked and maintained.  
Keep high-frequency source doors and panels tightly shut, keep  
spark gaps at correct setting, and use grounding and shielding to  
minimize the possibility of interference.  
D
Do not block or filter airflow to unit.  
STATIC (ESD) can damage PC boards.  
D
Put on grounded wrist strap BEFORE handling  
boards or parts.  
ARC WELDING can cause interference.  
D
Use proper static-proof bags and boxes to  
store, move, or ship PC boards.  
D
Electromagnetic energy can interfere with  
sensitive electronic equipment such as  
computers and computer-driven equipment  
such as robots.  
MOVING PARTS can cause injury.  
D
Be sure all equipment in the welding area is  
electromagneticallycompatible.  
D
D
Keep away from moving parts.  
Keep away from pinch points such as drive  
rolls.  
D
D
D
D
To reduce possible interference, keep weld cables as short as  
possible, close together, and down low, such as on the floor.  
Locate welding operation 100 meters from any sensitive elec-  
tronic equipment.  
WELDING WIRE can cause injury.  
Be sure this welding machine is installed and grounded  
according to this manual.  
D
Do not press gun trigger until instructed to do  
so.  
Do not point gun toward any part of the body,  
other people, or any metal when threading  
welding wire.  
If interference still occurs, the user must take extra measures  
such as moving the welding machine, using shielded cables,  
using line filters, or shielding the work area.  
D
1-4. Principal Safety Standards  
Safety in Welding and Cutting, ANSI Standard Z49.1, from American  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
from Compressed Gas Association, 1235 Jefferson Davis Highway,  
Suite 501, Arlington, VA 22202.  
Code for Safety in Welding and Cutting, CSA Standard W117.2, from  
Canadian Standards Association, Standards Sales, 178 Rexdale  
Boulevard, Rexdale, Ontario, Canada M9W 1R3.  
Safe Practices For Occupation And Educational Eye And Face  
Protection, ANSI Standard Z87.1, from American National Standards  
Institute, 1430 Broadway, New York, NY 10018.  
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126  
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-  
dent of Documents, U.S. Government Printing Office, Washington, D.C.  
20402.  
Recommended Safe Practices for the Preparation for Weldingand Cut-  
ting of Containers That Have Held Hazardous Substances, American  
Welding Society Standard AWS F4.1, from American Welding Society,  
550 N.W. LeJeune Rd, Miami, FL 33126  
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-  
tion Association, Batterymarch Park, Quincy, MA 02269.  
Cutting And Welding Processes, NFPA Standard 51B, from National  
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
OM-186 895 Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1-5. EMF Information  
Considerations About Welding And The Effects Of Low Frequency  
Electric And Magnetic Fields  
1. Keep cables close together by twisting or taping them.  
2. Arrange cables to one side and away from the operator.  
3. Do not coil or drape cables around your body.  
Welding current, as it flows through welding cables, will cause electro-  
magnetic fields. There has been and still is some concern about such  
fields. However, after examining more than 500 studies spanning 17  
years of research, a special blue ribbon committee of the National  
Research Council concluded that: “The body of evidence, in the  
committees judgment, has not demonstrated that exposure to power-  
frequency electric and magnetic fields is a human-health hazard.”  
However, studies are still going forth and evidence continues to be  
examined.Until the final conclusions of the research are reached, you  
may wish to minimize your exposure to electromagnetic fields when  
welding or cutting.  
4. Keep welding power source and cables as far away from opera-  
tor as practical.  
5. Connect work clamp to workpiece as close to the weld as possi-  
ble.  
About Pacemakers:  
To reduce magnetic fields in the workplace, use the following  
procedures:  
Pacemaker wearers consult your doctor first. If cleared by your doctor,  
then following the above procedures is recommended.  
OM-186 895 Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 CONSIGNES DE SECURITE LIRE AVANT  
UTILISATION  
som _nd_fre 5/97  
1-1. Signification des symboles  
SignifieMise en garde ! Soyez vigilant ! Cette procédure  
présente des risques de danger ! Ceux-ci sont identifiés  
par des symboles adjacents aux directives.  
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des  
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN  
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles  
et aux directives ci-dessous afin de connaître les mesures à prendre pour  
éviter tout danger.  
Y
Identifie un message de sécurité particulier.  
. Signifie NOTA ; n’est pas relatif à la sécurité.  
1-2. Dangers relatifs au soudage à l’arc  
Y
Les symboles présentés ci-après sont utilisés tout au long du  
présent manuel pour attirer votre attention et identifier les risques  
de danger. Lorsque vous voyez un symbole, soyez vigilant et  
suivez les directives mentionnées afin d’éviter tout danger. Les  
consignes de sécurité présentées ci-après ne font que résumer  
l’information contenue dans les normes de sécurité énumérées  
à la section 1-4. Veuillez lire et respecter toutes ces normes de  
sécurité.  
D
D
Ne pas toucher l’électrode quand on est en contact avec la pièce, la  
terre ou une électrode provenant d’une autre machine.  
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-le-  
champ les pièces endommagées. Entretenir l’appareil conformément  
à ce manuel.  
D
D
D
Porter un harnais de sécurité quand on travaille en hauteur.  
Maintenir solidement en place tous les panneaux et capots.  
Y
Y
L’installation, l’utilisation, l’entretien et les réparations ne doi-  
vent être confiés qu’à des personnes qualifiées.  
Fixer le câble de retour de façon à obtenir un bon contact métal-métal  
avec la pièce à souder ou la table de travail, le plus près possible de la  
soudure.  
Au cours de l’utilisation, tenir toute personne à l’écart et plus par-  
ticulièrement les enfants.  
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact  
avec tout objet métallique.  
UN CHOC ÉLECTRIQUE peut tuer.  
Un simple contact avec des pièces électriques peut  
provoquer une électrocution ou des blessures graves.  
L’électrode et le circuit de soudage sont sous tension  
dès que l’appareil est sur ON. Le circuit d’entrée et les  
circuits internes de l’appareil sont également sous  
Il y a DU COURANT CONTINU IMPORTANT dans les  
convertisseurs après la suppression de l’alimenta-  
tion électrique.  
D
Arrêter les convertisseurs, débrancher le courant électrique, et dé-  
charger les condensateurs d’alimentation selon les instructions  
indiquées dans la partie entretien avant de toucher les pièces.  
tension à ce moment-là. En soudage semi-automatique ou automatique,  
le fil, le dévidoir, le logement des galets d’entraînement et les pièces  
métalliques en contact avec le fil de soudage sont sous tension. Des  
matériels mal installés ou mal mis à la terre présentent un danger.  
D
D
Ne jamais toucher les pièces électriques sous tension.  
Porter des gants et des vêtements de protection secs ne comportant  
pas de trous.  
LES FUMÉES ET LES GAZ peuvent  
être dangereux.  
D
S’isoler de la pièce et de la terre au moyen de tapis ou d’autres  
moyens isolants suffisamment grands pour empêcher le contact phy-  
sique éventuel avec la pièce ou la terre.  
Ne pas se servir de source électrique àcourant électrique dans les zones  
humides, dans les endroits confinés ou là où on risque de tomber.  
Se servir d’une source électrique àcourant électrique UNIQUEMENT si le  
procédé de soudage le demande.  
Si l’utilisation d’une source électrique àcourant électrique s’avère néces-  
saire, se servir de la fonction de télécommande si l’appareil en est équipé.  
Couper l’alimentation ou arrêter le moteur avant de procéder à l’instal-  
lation, à la réparation ou à l’entretien de l’appareil. Déverrouiller  
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de  
sécurité).  
Installer et mettre à la terre correctement cet appareil conformément à  
son manuel d’utilisation et aux codes nationaux, provinciaux et  
municipaux.  
Toujours vérifier la terre du cordon d’alimentation Vérifier et s’assu-  
rer que le fil de terre du cordon d’alimentation est bien raccordé à la  
borne de terre du sectionneur ou que la fiche du cordon est raccordée  
à une prise correctement mise à la terre.  
En effectuant les raccordements d’entrée fixer d’abord le conducteur  
de mise à la terre approprié et contre-vérifier les connexions.  
Le soudage génère des fumées et des gaz. Leur  
inhalation peut être dangereux pour votre santé.  
D
D
D
D
D
Eloigner votre tête des fumées. Ne pas respirer  
les fumées.  
D
A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau  
de l’arc pour l’évacuation des fumées et des gaz de soudage.  
D
D
Si la ventilation est insuffisante, utiliser un respirateur à alimenta-  
tion d’air homologué.  
Lire les spécifications de sécurité des matériaux (MSDSs) et les  
instructions du fabricant concernant les métaux, les consomma-  
bles, les revêtements, les nettoyants et les dégraisseurs.  
Travailler dans un espace fermé seulement s’il est bien ventilé ou en  
portant un respirateur à alimentation d’air. Demander toujours à un  
surveillant dûment formé de se tenir à proximité. Des fumées et des  
gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxy-  
gène provoquant des blessures ou des accidents mortels. S’assu-  
rer que l’air de respiration ne présente aucun danger.  
Ne pas souder dans des endroits situés à proximité d’opérations de  
dégraissage, de nettoyage ou de pulvérisation. La chaleur et les  
rayons de l’arc peuvent réagir en présence de vapeurs et former des  
gaz hautement toxiques et irritants.  
D
D
D
D
D
D
D
Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas  
endommagé ou dénudé remplacer le cordon immédiatement s’il est  
endommagé un câble dénudé peut provoquer une électrocution.  
Mettre l’appareil hors tension quand on ne l’utilise pas.  
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffi-  
sante ou mal épissés.  
Ne pas souder des métaux munis d’un revêtement, tels que l’acier  
galvanisé, plaqué en plomb ou au cadmium à moins que le revête-  
ment n’ait été enlevé dans la zone de soudure, que l’endroit soit bien  
ventilé, et si nécessaire, en portant un respirateur à alimentation  
d’air. Les revêtements et tous les métaux renfermant ces éléments  
peuvent dégager des fumées toxiques en cas de soudage.  
D
D
D
D
Ne pas enrouler les câbles autour du corps.  
Si la pièce soudée doit être mise à la terre, le faire directement avec un  
câble distinct ne pas utiliser le connecteur de pièce ou le câble de  
retour.  
OM-186 895 Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LES RAYONS DE L’ARC peuvent pro-  
voquer des brûlures dans les yeux et  
sur la peau.  
LES ACCUMULATIONS DE GAZ ris-  
quent de provoquer des blessures ou  
même la mort.  
Le rayonnement de l’arc du procédé de soudage  
génère des rayons visibles et invisibles intenses  
(ultraviolets et infrarouges) susceptibles de provoquer  
des brûlures dans les yeux et sur la peau. Des étincelles sont projetées  
pendant le soudage.  
D
Fermer l’alimentation du gaz protecteur en cas de  
non utilisation.  
D
Veiller toujours à bien aérer les espaces confinés ou se servir d’un respi-  
rateur d’adduction d’air homologué.  
D
Porter un casque de soudage muni d’un écran de filtre approprié pour  
protéger votre visage et vos yeux pendant le soudage ou pour regar-  
der (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).  
DES PIÈCES CHAUDES peuvent pro-  
voquer des brûlures graves.  
D
D
Porter des protections approuvés pour les oreilles si le niveau sondre est  
trop élevé.  
Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair  
et de l’éblouissement; demander aux autres personnes de ne pas re-  
garder l’arc.  
D
D
Ne pas toucher des parties chaudes à mains nues  
Prévoir une période de refroidissement avant  
d’utiliser le pistolet ou la torche.  
D
Porter des vêtements de protection constitué dans une matière dura-  
ble, résistant au feu (cuir ou laine) et une protection des pieds.  
LE SOUDAGE peut provoquer un  
incendie ou une explosion.  
LES CHAMPS MAGNÉTIQUES peuvent  
affecter les stimulateurs cardiaques.  
Le soudage effectué sur des conteneurs fermés tels  
que des réservoirs, tambours ou des conduites peut  
provoquer leur éclatement. Des étincelles peuvent être  
projetées de l’arc de soudure. La projection d’étincel-  
D
D
Porteurs de stimulateur cardiaque, restez à distance.  
Les porteurs d’un stimulateur cardiaque doivent  
d’abord consulter leur médecin avant de s’approcher  
des opérations de soudage à l’arc, de gougeage ou  
de soudage par points.  
les, des pièces chaudes et des équipements chauds peut provoquer des  
incendies et des brûlures. Le contact accidentel de l’électrode avec des  
objets métalliques peut provoquer des étincelles, une explosion, un  
surchauffement ou un incendie. Avant de commencer le soudage, vérifier  
et s’assurer que l’endroit ne présente pas de danger.  
D
D
D
Se protéger et d’autres personnes de la projection d’étincelles et de  
métal chaud.  
Ne pas souder dans un endroit là où des étincelles peuvent tomber sur  
des substances inflammables.  
Déplacer toutes les substances inflammables à une distance de 10,7  
m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneuse-  
ment avec des protections homologués.  
Des étincelles et des matériaux chauds du soudage peuvent facile-  
ment passer dans d’autres zones en traversant de petites fissures et  
des ouvertures.  
LE BRUIT peut affecter l’ouïe.  
Le bruit des processus et des équipements peut affecter  
l’ouïe.  
D
Porter des protections approuvés pour les oreilles si  
le niveau sondre est trop élevé.  
D
D
D
D
Surveiller tout déclenchement d’incendie et tenir un extincteur à proxi-  
mité.  
Si des BOUTEILLES sont endomma-  
gées, elles pourront exploser.  
Le soudage effectué sur un plafond, plancher, paroi ou séparation  
peut déclencher un incendie de l’autre côté.  
Ne pas effectuer le soudage sur des conteneurs fermés tels que des  
réservoirs, tambours, ou conduites, à moins qu’ils n’aient été prépa-  
rés correctement conformément à AWS F4.1 (voir les normes de  
sécurité).  
Brancher le câble sur la pièce le plus près possible de la zone de sou-  
dage pour éviter le transport du courant sur une longue distance par  
des chemins inconnus éventuels en provoquant des risques d’élec-  
trocution et d’incendie.  
Des bouteilles de gaz protecteur contiennent du gaz  
sous haute pression. Si une bouteille est endomma-  
gée, elle peut exploser. Du fait que les bouteilles de gaz  
font normalement partie du procédé de soudage, les  
manipuler avec précaution.  
D
D
D
D
Protéger les bouteilles de gaz comprimé d’une chaleur excessive,  
des chocs mécaniques, du laitier, des flammes ouvertes, des étin-  
celles et des arcs.  
Placer les bouteilles debout en les fixant dans un support stationnai-  
re ou dans un porte-bouteilles pour les empêcher de tomber ou de  
se renverser.  
Tenir les bouteilles éloignées des circuits de soudage ou autres cir-  
cuits électriques.  
Ne jamais placer une torche de soudage sur une bouteille à gaz.  
Une électrode de soudage ne doit jamais entrer en contact avec une  
D
D
D
Ne pas utiliser le poste de soudage pour dégeler des conduites ge-  
lées.  
En cas de non utilisation, enlever la baguette d’électrode du porte-  
électrode ou couper le fil à la pointe de contact.  
Porter des vêtements de protection dépourvus d’huile tels que des  
gants en cuir, une chemise en matériau lourd, des pantalons sans re-  
vers, des chaussures hautes et un couvre chef.  
D
D
bouteille.  
D
Avant de souder, retirer toute substance combustible de vos poches  
telles qu’un allumeur au butane ou des allumettes.  
D
D
Ne jamais souder une bouteille pressurisée risque d’explosion.  
Utiliser seulement des bouteilles de gaz protecteur, régulateurs,  
tuyaux et raccords convenables pour cette application spécifique;  
les maintenir ainsi que les éléments associés en bon état.  
Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la  
bouteille.  
Maintenir le chapeau de protection sur la soupape, sauf en cas d’uti-  
lisation ou de branchement de la bouteille.  
Lire et suivre les instructions concernant les bouteilles de gaz com-  
primé, les équipements associés et les publications P-1 CGA énu-  
mérées dans les normes de sécurité.  
DES PARTICULES VOLANTES  
peuvent blesser les yeux.  
D
D
D
D
Le soudage, l’écaillement, le passage de la pièce  
à la brosse en fil de fer, et le meulage génèrent  
des étincelles et des particules métalliques vo-  
lantes. Pendant la période de refroidissement des soudures, elles ris-  
quent de projeter du laitier.  
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.  
OM-186 895 Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement  
et la maintenance  
Risque D’INCENDIE OU  
D’EXPLOSION.  
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
Ne pas placer l’appareil sur, au-dessus ou à proxi-  
mité de surfaces infllammables.  
D
Rester à l’écart des organes mobiles comme le  
ventilateur.  
D
Maintenir fermés et fixement en place les portes,  
panneaux, recouvrements et dispositifs de  
protection.  
D
D
Ne pas installer l’appareil à proximité de produits inflammables  
Ne pas surcharger l’installation électrique s”assurer que l’alimen-  
tation est correctement dimensionné et protégé avant de mettre  
l’appareil en service.  
LE RAYONNEMENT HAUTE FRÉ-  
QUENCE (H.F.) risque de provoquer  
des interférences.  
LA CHUTE DE L’APPAREIL peut  
blesser.  
D
Le rayonnement haute frequence peut provoquer  
des interférences avec les équipements de ra-  
dionavigationet de communication, les services  
de sécurité et les ordinateurs.  
D
Utiliser l’anneau de levage uniquement pour sou-  
lever l’appareil, NON PAS les chariot, les bouteil-  
les de gaz ou tout autre accessoire.  
D
Demander seulement à des personnes qualifiées familiarisées  
avec des équipements électroniques de faire fonctionner l’installa-  
tion.  
L’utilisateur est tenu de faire corriger rapidement par un électricien  
qualifié les interférences résultant de l’installation.  
D
Utiliser un engin d’une capacité appropriée pour  
soulever l’appareil.  
D
En utilisant des fourches de levage pour déplacer l’unité, s’assurer  
que les fourches sont suffisamment longues pour dépasser du côté  
opposé de l’appareil.  
D
D
Si le FCC signale des interférences, arrêter immédiatement l’appa-  
reil.  
L’EMPLOI EXCESSIF peut  
D
D
Effectuer régulièrement le contrôle et l’entretien de l’installation.  
Maintenir soigneusement fermés les portes et les panneaux des  
sources de haute fréquence, maintenir les éclateurs à une distance  
correcte et utiliser une terre et et un blindage pour réduire les interfé-  
rences éventuelles.  
SURCHAUFFER L’ÉQUIPEMENT.  
D
Prévoir une période de refroidissement, respec-  
ter le cycle opératoire nominal.  
D
Réduire le courant ou le cycle opératoire avant de  
recommancer le soudage.  
LE SOUDAGE À L’ARC risque de  
provoquer des interférences.  
D
Ne pas obstruer les passages d’air du poste.  
LES CHARGES ÉLECTROSTATI-  
QUES peuvent endommager les cir-  
cuits imprimés.  
D
L’énergie électromagnétique risque de provoquer  
des interférences pour l’équipement électronique  
sensible tel que les ordinateurs et l’équipement  
commandé par ordinateur tel que les robots.  
D
D
Veiller à ce que tout l’équipement de la zone de soudage soit com-  
D
Établir la connexion avec la barrette de terre  
avant de manipuler des cartes ou des pièces.  
Utiliser des pochettes et des boîtes antistatiques  
pour stocker, déplacer ou expédier des cartes de  
circuits imprimes.  
patible électromagnétiquement.  
Pour réduire la possibilité d’interférence, maintenir les câbles de  
soudage aussi courts que possible, les grouper, et les poser aussi  
bas que possible (ex. par terre).  
Veiller à souder à une distance de 100 mètres de tout équipement  
électronique sensible.  
Veiller à ce que ce poste de soudage soit posé et mis à la terre  
conformément à ce mode d’emploi.  
En cas d’interférences après avoir pris les mesures précédentes, il  
incombe à l’utilisateur de prendre des mesures supplémentaires tel-  
les que le déplacement du poste, l’utilisation de câbles blindés, l’uti-  
lisation de filtres de ligne ou la pose de protecteurs dans la zone de  
travail.  
D
D
D
D
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
D
Ne pas s’approcher des organes mobiles.  
Ne pas s’approcher des points de coincement  
tels que des rouleaux de commande.  
LES CHAMPS MAGNÉTIQUES peuvent  
affecter les stimulateurs cardiaques.  
LES FILS DE SOUDAGE peuvent pro-  
voquer des blessures.  
D
D
Porteurs de stimulateur cardiaque, restez à dis-  
tance.  
Les porteurs d’un stimulateur cardiaque doivent  
d’abord consulter leur médecin avant de s’appro-  
cher des opérations de soudage à l’arc, de gou-  
geage ou de soudage par points.  
D
Ne pas appuyer sur la gachette avant d’en avoir  
reçu l’instruction.  
Ne pas diriger le pistolet vers soi, d’autres person-  
nes ou toute pièce mécanique en engageant le fil  
de soudage.  
D
OM-186 895 Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-4. Principales normes de sécurité  
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
de la Compressed Gas Association, 1235 Jefferson Davis Highway,  
Suite 501, Arlington, VA 22202.  
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126  
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent  
of Documents, U.S. Government Printing Office, Washington, D.C.  
20402.  
Règles de sécurité en soudage, coupage et procédés connexes, norme  
CSA W117.2, de l’Association canadienne de normalisation, vente de  
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.  
RecommendedSafe Practice for the Preparation for Welding and Cut-  
ting of Containers That Have Held Hazardous Substances, norme AWS  
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL  
33126  
Safe Practices For Occupation And Educational Eye And Face Protec-  
tion, norme ANSI Z87.1, de l’American National Standards Institute,  
1430 Broadway, New York, NY 10018.  
NationalElectrical Code, NFPA Standard 70, de la National Fire Protec-  
tion Association, Batterymarch Park, Quincy, MA 02269.  
Cutting and Welding Processes, norme NFPA 51B, de la National Fire  
Protection Association, Batterymarch Park, Quincy, MA 02269.  
1-5. Information sur les champs électromagnétiques  
Données sur le soudage électrique et sur les effets, pour l’organisme,  
des champs magnétiques basse fréquence  
Afin de réduire les champs électromagnétiques dans l’environnement  
de travail, respecter les consignes suivantes :  
1
Garder les câbles ensembles en les torsadant ou en les  
attachant avec du ruban adhésif.  
Le courant de soudage, pendant son passage dans les câbles de sou-  
dage, causera des champs électromagnétiques. Il y a eu et il y a encore  
un certain souci à propos de tels champs. Cependant, après avoir ex-  
aminé plus de 500 études qui ont été faites pendant une période de  
recherche de 17 ans, un comité spécial ruban bleu du National Re-  
search Council a conclu: “L’accumulation de preuves, suivant le  
jugement du comité, n’a pas démontré que l’exposition aux champs  
magnétiqueset champs électriques à haute fréquence représente un  
risque à la santé humaine”. Toutefois, des études sont toujours en cours  
et les preuves continuent à être examinées. En attendant que les con-  
clusions finales de la recherche soient établies, il vous serait  
souhaitablede réduire votre exposition aux champs électromagnéti-  
ques pendant le soudage ou le coupage.  
2
3
Mettre tous les câbles du côté opposé de l’opérateur.  
Ne pas courber pas et ne pas entourer pas les câbles autour de  
votre corps.  
4
5
Garder le poste de soudage et les câbles le plus loin possible de  
vous.  
Relier la pince de masse le plus près possible de la zone de  
soudure.  
Consignes relatives aux stimulateurs cardiaques :  
Les personnes qui portent un stimulateur cardiaque doivent avant tout  
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est  
alors recommandé de respecter les consignes cidessus.  
OM-186 895 Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 2 DEFINITIONS  
2-1. Warning Label Definitions  
A. Warning! Watch Out! There  
are possible hazards as  
shown by the symbols.  
B. Drive rolls can injure fingers.  
A
B
C
C. Welding wire and drive parts  
are at welding voltage during  
operation keep hands and  
metal objects clear.  
1
Electric shock can kill.  
1.1 Wear dry insulating gloves.  
Do not touch electrode with  
bare hand. Do not wear wet or  
damaged gloves.  
1.2 Protect yourself from electric  
shock by insulating yourself  
from work and ground.  
1
2
1.1  
2.1  
3.1  
4.1  
1.2  
1.3  
1.3 Disconnect input plug or  
power before working on  
machine.  
2
Breathing welding fumes can  
be hazardous to your health.  
2.2  
2.3  
2.1 Keep your head out of the  
fumes.  
2.2 Use forced ventilation or local  
exhaust to remove the fumes.  
2.3 Use ventilating fan to remove  
fumes.  
3
4
5
3.2  
3.3  
3
Welding sparks can cause  
explosion or fire.  
3.1 Keep flammables away from  
welding. Don’t weld near  
flammables.  
3.2 Welding sparks can cause  
fires. Have a fire extinguisher  
nearby and have a watch  
person ready to use it.  
+ + +  
3.3 Do not weld on drums or any  
closed containers.  
4
Arc rays can burn eyes and  
injure skin.  
6
4.1 Wear hat and safety glasses.  
Use ear protection and button  
shirt collar. Use welding  
helmet with correct shade of  
filter. Wear complete body  
protection.  
+
S-178 936  
5
Become trained and read the  
instructions before working on  
the machine or welding.  
6
Do not remove or paint over  
(cover) the label.  
OM-186 895 Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-2. Rating Label For CE Products  
S/N:  
U1  
I =  
1
50/60 Hz  
IP 23  
24 V  
1
=
7.0  
A
U2  
=
I =  
500 A  
2
100 V  
X 100 %  
178 794-A  
2-3. Symbols And Definitions  
Some symbols are found only on CE products.  
NOTE  
On  
Off  
Input  
Output  
Amperes  
Volts  
Hertz  
AlternatingCurrent  
Circuit Breaker  
Duty Cycle  
Wire Feed  
A
IP  
V
Hz  
U1  
X
Degree Of  
Protection  
Gas Metal Arc  
Welding (GMAW)  
Gun  
Jog  
Primary Voltage  
Spot Weld Time  
Line Connection  
Continuous Weld  
Purge  
Spot Weld  
Burnback Time  
Load Voltage  
Preflow Time  
Postflow Time  
Rated Current  
Read Instructions  
Primary Voltage  
Primary Current  
U2  
I1  
I2  
U1  
OM-186 895 Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 3 INSTALLATION  
3-1. Specifications  
Welding  
Type of Input  
Power  
Wire  
Diameter  
Range  
Welding  
Circuit  
Rating  
Wire Feed  
Speed Range  
IP  
Rating  
Overall  
Dimensions  
Weight  
Power  
Source Type  
Length: 597 mm  
(23-1/2 in)  
0.6 To 2 mm  
100 Volts,  
500 Amperes,  
100%  
Constant Voltage  
(.023 To 5/64 in)  
24 Volts AC  
(CV) DC With  
Single Phase  
14-Pin And  
7 Amperes 50/60  
Contactor  
1.9 To 19 mpm  
(75 to 750 ipm)  
Width: 273 mm  
(10-3/4 in)  
IP 23  
15.9 kg (35 lb)  
Max Spool  
Weight:  
27 kg (60 lb)  
Duty Cycle  
Hz  
Height: 279 mm  
(11 in)  
Control  
3-2. Site Selection  
1
Wire Feeder  
Lifting Eye  
Rubber Feet  
Slot  
2
3
4
5
6
1
Choose slot that allows all rubber  
feet to sit securely on top of welding  
power source.  
7
5
6
Wire Spool/Reel  
Gas Cylinder (Customer  
Supplied)  
7
Welding Power Source  
Y
Do not put feeder where  
welding wire hits cylinder.  
Y
Do not move or operate  
equipment when it could tip.  
8
Lifting Handle  
Y
Manuallyuse handle to move  
or briefly lift feeder.  
Y
Do not use lifting hook or  
other devices to lift or  
suspend feeder by the  
handle.  
2
4
3
8
801 920-C / Ref. 152 468-A / 155 242 / 801 919-C / 188 674  
OM-186 895 Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-3. Gun Recommendation Table  
Process  
Gun  
GMAW Hard or Corded Wires  
FCAW Self-Shielding Wires  
M25 Or M40  
GA-40GL  
3-4. Equipment Connection Diagrams  
1
2
3
CV Welding Power Source  
With 24 VAC Power  
CV Welding Power Source  
Without 24 VAC Power  
115 Volts AC /24 Volts AC  
Power Adapter  
4
5
6
14-Pin Control Cord  
Weld Cable (Required)  
Work  
1
4
6
3
5
2
115VAC  
4
Contactor  
6
5
3-5. 14-Pin Receptacle, Shielding Gas And Optional Volt Sense Lead  
1
Gas Hose With 5/8-18 Right-  
hand Thread Fittings (Cus-  
tomer Supplied)  
3
2
14 Pin Receptacle RC9  
2
Use interconnecting cord to make  
connection to welding power  
source.  
3
Power Switch  
1
Tools Needed:  
5/8, 11/16 in  
801 921-C  
OM-186 895 Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-6. 14-Pin Receptacle Information  
Pin*  
Pin Information  
A
B
G
C
D
E
F
24 volts ac with respect to pin G.  
Contact closure to A completes 24 volts ac contactor control circuit.  
Circuit common for 24 volts AC circuit.  
J
A
E
K
I
B
N
L
C
+10 volts dc output to remote control with respect to pin D.  
Remote control circuit common.  
H
M
F
D
G
0 to +10 volts dc input command signal from remote control with respect to pin D.  
Current feedback; 0 to 10 volts dc, 1 V/100 A  
H
Voltage feedback; 0 to 10 volts dc, 1 V/10 arc volts  
*The remaining pins are not used.  
Ref. S-0004-A  
3-7. Connecting Welding Gun And Weld Cable  
1
2
Gun/FeederAdapter  
Gun Connector  
Insert gun connector into adapter.  
Tighten locking ring.  
3
4
Weld Cable Terminal  
Weld Cable From Welding  
Power Source  
1
2
4
3
Tools Needed:  
9/16, 5/8 in  
801 922-B  
OM-186 895 Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-8. Optional Meter Circuit Board Settings  
1
2
3
4
Meter Circuit Board  
DIP Switch S2  
Potentiometer R18  
Receptacle RC16  
Wiring harness with free-hanging  
plug PLG42 connects to RC16.  
For voltage feedback from voltage  
sensing lead, connect plug PLG43  
from unit wiring harness to PLG42.  
For voltage feedback from welding  
power source to wire feeder 14-pin  
receptacle, connect plug PLG41  
from unit wiring harness to PLG42.  
1
2
1
2
X Means switch position does not affect  
specified function.  
.
Means switch must be in this position.  
Voltage Sensing Function  
Digital Meter Display  
Arc Voltage Sensing Using Voltage Sensing  
Lead For Welding Power Source That Does  
Not Support Pins F And H  
Meters/Minute  
1
2
3
4
5
1
2
3
4
5
Or  
Or  
Inches/Minute  
Arc Voltage Sensing Using Feedback From  
Welding Power Source That Does Support  
Pins F And H  
1
2
3
4
5
1
2
3
4
5
Tools Needed:  
1/4 in  
801 925-C / Ref. 186 266  
OM-186 895 Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-9. Motor Start/Burnback Control  
To change wire feed starting speed  
proceed as follows:  
Turn Off unit and welding power  
source.  
1
Remove wrapper.  
1
2
Motor Board PC1  
Motor Start Control  
Potentiometer R73  
Remove protective white rubber  
cap before making adjustment.  
Adjust potentiometer R73 using a  
small nonconductive screwdriver.  
Rotate potentiometer clockwise to  
increase time it takes the motor to  
ramp up to speed.  
3
Burnback Potentiometer R42  
Remove protective white rubber  
cap before making adjustment.  
Adjust potentiometer R42 using a  
small nonconductive screwdriver.  
Rotate potentiometer clockwise to  
increase burnback time.  
2
Reinstall wrapper.  
3
Tools Needed:  
Non-Conductive  
1/4 in  
801 925-C / 192 653  
OM-186 895 Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-10. Installing Wire Guide And Drive Roll  
Install and secure inlet wire guide  
on either assembly, and  
intermediatewire guide on 4 drive  
roll assembly only. Install drive rolls  
and turn drive roll nut one click.  
During maintenance intervals,  
remove drive rolls, and clean  
grooves using a wire brush. Check  
groove of drive roll for pitting or  
increase in the depth of the groove  
indicating drive roll is worn out.  
Tools Needed:  
3/8 in  
801 923-C  
OM-186 895 Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3-11. Installing And Threading Welding Wire  
1
2
Retaining Ring  
Hub Tension Adjustment Nut  
If necessary, move hub on support  
for use of different size wire spool.  
Remove retaining ring, and install  
spool so hub pin fits spool hole.  
Reinstall retaining ring.  
1
2
3
Adjust tension nut so wire is taut  
when wire feed stops.  
3
Pressure Assembly  
Adjustment Knob  
Lay gun cable out straight.  
A
Open pressure assembly,  
hold wire tightly, and cut off  
end. Push wire through guides  
into gun.  
B
C
Close and tighten pressure  
assembly. Press JOG button  
until wire comes out gun.  
To adjust drive roll pressure,  
press gun trigger to feed wire  
against wood surface. Tighten  
knob so wire does not slip.  
Cut off wire. Close door.  
A
B
C
Tighten  
WOOD  
Tools Needed:  
15/16 in  
Ref. 801 924-B / S-0627-A  
OM-186 895 Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 4 OPERATION  
4-1. Front Panel Controls  
1
2
Optional Voltage/Wire Speed  
Meter  
1
Optional Voltage/Wire Speed  
Switch  
Use to choose volts or wire feed  
speed display.  
2
3
3
Optional Remote Voltage  
Control  
Use to set welding power source  
voltage at the wire feeder. Numbers  
are for reference only.  
4
5
Wire Speed Control  
Jog/Purge Switch  
4
Use Jog position to momentarily  
feed welding wire at speed set on  
Wire Speed control without ener-  
gizing welding circuit or shielding  
gas valve.  
Use Purge position to momentarily  
energizegas valve to purge air from  
gun or adjust gas regulator.  
5
6
Trigger Hold Switch  
Push up to weld without holding gun  
trigger throughout the weld cycle.  
To start weld cycle, press and re-  
lease gun trigger within three se-  
conds after an arc has been struck.  
To end weld, press and release gun  
trigger.  
Power switch is on rear panel (see  
6
Ref. 188 340-A  
OM-186 895 Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-2. Optional Side Panel Controls  
1
Preflow Control  
Control sets time gas flows before  
welding wire is energized. Time  
range is 0 to 5 seconds.  
1
2
Postflow Control  
Control sets time gas flows after  
completion of burnback. Time  
range is 0 to 5 seconds.  
3
Spot Time Control  
2
Factory set for 0.25 to 5 seconds of  
spot time. Rotating knob fully  
counterclockwise  
selects  
an  
untimed continuous weld.  
Close side door.  
3
Ref. 801 923-C / Ref. 186 589  
SECTION 5 MAINTENANCE & TROUBLESHOOTING  
5-1. Routine Maintenance  
Y
Disconnect power before maintaining.  
3 Months  
Repair Or  
Replace  
Cracked  
Clean And  
Tighten  
Weld  
Replace  
Unreadable  
Labels  
Weld Cable  
Terminals  
Replace  
Cracked  
Parts  
14-Pin Cord  
Gun Cable  
Gas Hose  
6 Months  
Blow Out Or Vacuum  
Clean  
Drive  
Rolls  
Inside,  
OR  
During Heavy Service,  
Clean Monthly  
OM-186 895 Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-2. Overload Protection  
Y
Turn Off wire feeder and  
welding power source. Stop  
engine  
on  
welding  
1
generator.  
1
Circuit Breaker CB1  
CB1 protects wire feeder from over-  
load.  
Correct problem and manually  
reset breaker.  
801 921-C  
5-3. Troubleshooting  
Trouble  
Remedy  
Wire does not feed, unit completely inop- Turn Power switch On.  
erative.  
Check 14pin receptacle RC9 connections.  
Check input power.  
Wire does not feed.  
Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s  
Manual.  
Have Factory Authorized Service Agent check drive motor and control board PC1.  
Use correct size drive roll (see Parts List).  
Wire feeds erratically.  
Clean or replace dirty or worn drive roll (see Section 3-10).  
Remove weld spatter around nozzle opening.  
Replace contact tip or liner. See gun Owner’s Manual.  
Have Factory Authorized Service Agent check drive motor and control board PC1.  
Wire feeds when Jog switch is pressed Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s  
but not when gun trigger is pressed. Manual.  
Wire feeds as soon as power is applied. Check gun trigger. See gun Owner’s Manual.  
Wire does not feed until trigger is Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads.  
pressed but continues to feed after trig-  
ger is released.  
Gas valve rattles loudly and wire feeds Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads.  
slowly or erratically.  
Gas does not flow; wire feeds.  
OM-186 895 Page 20  
Check gas valve and flowmeter.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SECTION 6 ELECTRICAL DIAGRAM  
186 738-B  
Figure 6-1. Circuit Diagram For Wire Feeder With Optional Equipment  
OM-186 895 Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7 PARTS LIST  
7
8
6
9
10  
11  
12  
3
13  
2
12  
11  
1
5
14  
4
15  
16  
21  
50  
23  
22  
49  
24  
17  
20  
48  
19  
18  
51  
53  
52  
25  
26  
47  
27  
28  
46  
29  
30  
45  
32  
33  
34  
35  
39  
40  
31  
41  
36  
42  
37  
43  
23  
38  
44  
. Hardware is common and  
801 990-C  
not available unless listed.  
Figure 7-1. Main Assembly  
OM-186 895 Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Figure 7-1. Main Assembly  
Quantity  
. . . 1 . . . . . . . . . . . . . 089 899 . . . LATCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . . . . +186 674 . . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . 178 936 . . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . . . . . . . . 187 909 . . . HANDLE, lifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 604 423 . . . GRIP, handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . . . . . . . . 188 674 . . . LABEL, caution incorrect lifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . . . . . . . . . 072 094 . . . HUB & SPINDLE ASSEMBLY, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . . . . . . 058 427 . . . . RING, retaining spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . . . . . . . . 180 572 . . . . SHAFT, spool support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 9 . . . . . . . . . . . . . 010 233 . . . . SPRING, cprsn .970 OD x .120 wire x 1.250 . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . . . . . . . . . 057 971 . . . . WASHER, flat stl keyed 1.500dia x .125thk . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . . . . . . . . . 010 191 . . . . WASHER, fbr .656 ID x 1.500 OD x .125thk . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 12 . . . . . . . . . . . . . 058 628 . . . . WASHER, brake stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 13 . . . . . . . . . . . . . 058 428 . . . . HUB, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . . . . . . . . . . 135 205 . . . . NUT, stl slflkg hex reg .625-11 w/nylon insert . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 15 . . . . . . . . . . . . . 137 461 . . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . . . . . . . . . 134 306 . . . FOOT, rbr 1.250dia x 1.375 high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 17 . . . . PC1 . . . . 192 652 . . . CIRCUIT CARD, motor speed control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG1 . . . 115 093 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG3 . . . 115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG4 . . . 115 091 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG5 . . . 130 203 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 18 . . . . . . . . . . . . . 134 201 . . . STAND-OFF SUPPORT, PC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
. . . 19 . . . . . . . . . . . . . 131 181 . . . WIRE GUIDE & NUT (22A Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 20 . . . . PC3 . . 186 297 . . . CIRCUIT CARD, timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . 098 691 . . . STAND-OFF, No 6-32 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG1 . 115 093 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG3 . 135 409 . . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG33 . 115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG51 . 115 091 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 21 . . . . . . . . . . . 176 518 . . . FITTING, pipe brs elb 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 22 . . . . . . . . . . . 188 408 . . . FITTING, barb flow switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 23 . . . . . . . . . . . 188 442 . . . WASHER, shldr .515 ID 1.000 OD x .094thk . . . . . . . . . . . . . . . . . . . . . . . . . 8  
. . . 24 . . . . . . . . . . . 163 603 . . . SWITCH, flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 25 . . . . . . . . . . . 601 881 . . . NUT, .500-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 26 . . . . S1 . . . . . 111 997 . . . SWITCH, rocker SPST 10A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 27 . . . . . . . . . . . . . 112 863 . . . FITTING, hose brs barbed M 1/4tbg x 5/8-18 SAE . . . . . . . . . . . . . . . . . . . . 1  
. . . 28 . . . . . . . . . . . 126 693 . . . CABLE, sensing 15ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 29 . . . . . . . . . . . . . 605 227 . . . NUT, nyl hex jam .750NPST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 30 . . . . CB1 . . . . 161 078 . . . CIRCUIT BREAKER, man reset 1P 7A 250VAC . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 31 . . . . M1 . . . . 193 188 . . . MOTOR, gear 24VDC 146RPM (consisting of) . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . *136 745 . . . . BRUSH & SPRING ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 32 . . . . GS1 . . . . 125 785 . . . VALVE, 24VAC 2 way custom port 1/8 orf . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 33 . . . . RC9 . . . . 152 492 . . . RECEPTACLE W/PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 34 . . . . R1 . . . . . 073 562 . . . POTENTIOMETER, C sltd sft1/T 2W 10K ohm . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 35 . . . . R50 . . 035 897 . . . POTENTIOMETER, C sltd sft1/T 2W 1K linear . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 36 . . . . S2 . . . . . 134 846 . . . SWITCH, tgl SPTT 6A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 37 . . . . S3 . . . . . 134 847 . . . SWITCH, tgl SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 187 577 . . . COVER, opening meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . 133 644 . . . FRAME, snap-in switch rocker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 38 . . . . PC2 . . 186 268 . . . CIRCUIT CARD, meter (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . LCD1 . . . 181 355 . . . . METER, digital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG15 . 115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG16 . 131 055 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . 115 443 . . . STAND-OFF, 6-32 x .750 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
OM-186 895 Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 7-1. Main Assembly (Continued)  
. . . 39 . . . . . . . . . . . . . 192 955 . . . CASE ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 40 . . . LED1 . 179 203 . . . LED, 5100 2.0V 20MA green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 41 . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE (order by model and serial number) . . . . . . . . . . . . . . . . . . . . 1  
. . . 42 . . . . . . . . . . . . . 097 924 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 43 . . . . . . . . . . . 097 924 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 44 . . . . . . . . . . . 162 736 . . . FITTING, pipe brs qdisc fem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . 082 367 . . . FITTING, brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . 188 428 . . . HOSE, water 15.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . 188 429 . . . HOSE, water 25.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 45 . . . . . . . . . . . . . 187 246 . . . ADAPTER, gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 46 . . . . . . . . . . . . . 178 937 . . . LABEL, warning electric shock and pinch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 47 . . . . . . . . . . . . . 192 875 . . . PLATE, insulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 48 . . . . . . . . Fig 7-2 & 7-3 . . . WIRE DRIVE ASSEMBLIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 49 . . . . . . . . . . . . . 188 149 . . . GUIDE, wire inlet(consisting of) (4 drive roll) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 50 . . . . . . . . . . . . . 082 050 . . . . LINER, monocoil inlet wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 082 036 . . . . GUIDE, wire inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 187 421 . . . TUBE, guide .030-.035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 187 422 . . . TUBE, guide .045-.062 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 51 . . . . . . . . . . . . . 010 291 . . . WASHER, flat .625 x 1.250 OD x .125thk nylafil (22A Model) . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . 191 002 . . . KIT, gun connection (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . RC2 . . . . 048 282 . . . . RECEPTACLE w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 52 . . . . . . . . . . . 093 551 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 53 . . . . . . . . . . . 186 587 . . . PLATE, control timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
+When ordering a component originally displaying a precautionary label, the label should also be ordered.  
OPTIONAL  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-186 895 Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 7-2. Drive Assembly, Wire (2 Drive Roll) (Fig 7-1 Item 48)  
. . . 1 . . . . . . . . . . . . . 602 009 . . . SCREW, .250-20 x 1.250 soc hd hex gr 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . . . . . 172 075 . . . CARRIER, drive roll w/component 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . 054 263 . . . SCREW, thumb stl .250-20 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . . . . . . . . 010 224 . . . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . . . . . . . . 166 072 . . . SPACER, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . . . . . . . . . 089 562 . . . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . . . . . . 085 244 . . . WASHER, cupped stl .328 ID x .812 OD x .125 . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . . . . . . . . 089 477 . . . SPRING, cprsn .770 OD x .105 wire x 1.225 . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 9 . . . . . . . . . . . . . 085 243 . . . KNOB, adjustment tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . . . . . . . . . 166 071 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . . . . . . . . . 151 828 . . . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 12 . . . . . . . . . . . . . 079 634 . . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . . . . . . . . . . 144 172 . . . FITTING, hose brs barbed m 3/16 tbg x .250-20 . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . . . . . . . . . . 172 391 . . . HOUSING, adapter gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 15 . . . . . . . . . . . . . 048 449 . . . WASHER, shldr nyl .363 OD x .194 ID x .703 . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . . . . . . . . . 124 778 . . . KNOB, T 2.000 bar w/.312-18 x 1.000lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 17 . . . . . . . . . . . . . 605 308 . . . RING, rtng ext .500 shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 18 . . . . . . . . . . . . . 079 625 . . . WASHER, wave .500 ID x .750 OD x .015thk . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 19 . . . . . . . . . . . . . 121 271 . . . SCREW, .250-20 x .500 soc hd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 20 . . . . . . . . . . . . . 172 076 . . . CARRIER, drive roll w/components 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 21 . . . . . . . . . . . . . 092 865 . . . KEY, stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
9
8
7
10  
12  
11  
6
5
4
3
2
1
13  
14  
21  
20  
15  
19  
16  
17  
18  
802 019-A  
Figure 7-2. Drive Assembly, Wire (2 Drive Roll )  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-186 895 Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 7-3. Drive Assembly, Wire(4 Drive Roll) (Fig 7-1 Item 48)  
. . . 1 . . . . . . . . . . . . . 602 009 . . . SCREW, .250-20 x 1.250 soc hd hex gr 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 2 . . . . . . . . . . . . . 172 075 . . . CARRIER, drive roll w/component 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 3 . . . . . . . . . . . . . 166 072 . . . SPACER, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 4 . . . . . . . . . . . . . 054 263 . . . SCREW, thumb stl .250-20 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 5 . . . . . . . . . . . . . 010 224 . . . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 6 . . . . . . . . . . . . . 089 562 . . . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 7 . . . . . . . . . . . . . 085 244 . . . WASHER, cupped stl .328 ID x .812 OD x .125 . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 8 . . . . . . . . . . . . . 089 477 . . . SPRING, cprsn .770 OD x .105 wire x 1.225 . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 9 . . . . . . . . . . . . . 085 243 . . . KNOB, adjustment tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 10 . . . . . . . . . . . . . 166 071 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . . . . . . . . . 079 634 . . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . . . . . . . . . . . 151 828 . . . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 13 . . . . . . . . . . . . . 166 338 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . . . . . . . . . . 605 308 . . . RING, rtng ext .500 shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 15 . . . . . . . . . . . . . 187 325 . . . INSULATOR, drive assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . . . . . . . . . 144 172 . . . FITTING, hose brs barbed m 3/16 tbg x .250-20 . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 17 . . . . . . . . . . . . . 166 337 . . . HOUSING, adapter gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 18 . . . . . . . . . . . . . 168 590 . . . BUSHING, insulating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 19 . . . . . . . . . . . . . 072 010 . . . WASHER, shldr .316 ID x .812 OD x .187thk . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 20 . . . . . . . . . . . . . 124 778 . . . KNOB, T 2.000 bar w/.312-18 x 1.000lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 21 . . . . . . . . . . . . . 079 625 . . . WASHER, wave .500 ID x .750 OD x .015thk . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 22 . . . . . . . . . . . . . 092 865 . . . KEY, stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 23 . . . . . . . . . . . . . 172 077 . . . CARRIER, drive roll keyed 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 24 . . . . . . . . . . . . . 121 271 . . . SCREW, .250-20 x .500 soc hd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
12  
11  
10  
13  
9
14  
8
7
6
5
15  
4
3
16  
2
1
21  
24  
23  
20  
22  
19  
18  
17  
802 018-A  
Figure 7-3. Drive Assembly, Wire (4 Drive Roll )  
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-186 895 Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 7-1. Drive Roll And Wire Guide Kits (2 Drive Roll)  
Base selection of drive rolls upon the following recommended usages:  
1. V-Grooved rolls for hard wire.  
2. U-Grooved rolls for soft and soft shelled cored wires.  
3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).  
4. V-Knurled rolls for hard shelled cored wires.  
NOTE  
5. Drive roll types may be mixed to suit particular requirements (example:  
V-Knurled roll in combination with U-Grooved).  
Wire Diameter  
Drive Roll  
Part No.  
Inlet  
Kit No.  
Wire Guide  
Fraction  
.023/.025 in  
.030 in  
Decimal  
.023/.025 in  
.030 in  
Metric  
0.6 mm  
0.8 mm  
0.9 mm  
Type  
087 131  
079 594  
079 595  
087 130  
053 695  
053 700  
V-Grooved  
V-Grooved  
V-Grooved  
056 192  
056 192  
056 192  
.035 in  
.035 in  
.040 in  
.045 in  
.052 in  
1/16 in  
.040 in  
.045 in  
.052 in  
.062 in  
1.0 mm  
1.2 mm  
1.3 mm  
1.6 mm  
161 189  
079 596  
079 597  
079 598  
053 696  
053 697  
053 698  
053 699  
V-Grooved  
V-Grooved  
V-Grooved  
V-Grooved  
056 192  
056 193  
056 193  
056 195  
.035 in  
.045 in  
.052 in  
.035 in  
.045 in  
.052 in  
0.9 mm  
1.2 mm  
1.3 mm  
044 749  
079 599  
079 600  
072 000  
053 701  
053 702  
U-Grooved  
U-Grooved  
U-Grooved  
056 192  
056 193  
056 193  
1/16 in  
5/64 in  
.062 in  
.079 in  
1.6 mm  
2.0 mm  
079 601  
079 602  
053 706  
053 704  
U-Grooved  
U-Grooved  
056 195  
056 195  
.035 in  
.035 in  
0.9 mm  
079 606  
132 958  
V-Knurled  
056 192  
.045 in  
.052 in  
1/16 in  
.045 in  
.052 in  
.062 in  
1.2 mm  
1.3 mm  
1.6 mm  
079 607  
079 608  
079 609  
132 957  
132 956  
132 955  
V-Knurled  
V-Knurled  
V-Knurled  
056 193  
056 193  
056 195  
.068-.072 in  
5/64 in  
.068-.072 in  
.079 in  
1.8 mm  
2.0 mm  
089 984  
079 610  
132 959  
132 960  
V-Knurled  
V-Knurled  
056 195  
056 195  
.045 in  
.052 in  
1/16 in  
5/64 in  
.045 in  
.052 in  
.062 in  
.079 in  
1.2 mm  
1.3 mm  
1.6 mm  
2.0 mm  
083 318  
083 317  
079 614  
079 615  
083 489  
083 490  
053 708  
053 710  
U-Cogged  
U-Cogged  
U-Cogged  
U-Cogged  
056 193  
056 193  
056 195  
056 195  
S-0157-C  
OM-186 895 Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 7-2. Drive Roll & Wire Guide Kits (4 Drive Roll)  
Base selection of drive rolls upon the following recommended usages:  
1. V-Grooved rolls for hard wire.  
2. U-Grooved rolls for soft and soft shelled cored wires.  
3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).  
4. V-Knurled rolls for hard shelled cored wires.  
NOTE  
5. Drive roll types may be mixed to suit particular requirements (example:  
V-Knurled roll in combination with U-Grooved).  
Wire Diameter  
Decimal  
.023/.025 in .023/.025 in  
Drive Roll  
Wire Guide  
Kit No.  
Fraction  
Metric  
0.6 mm  
0.8 mm  
0.9 mm  
Part No.  
Type  
Inlet  
Intermediate  
087 132  
046 780  
046 781  
087 130  
053 695  
053 700  
V-Grooved  
V-Grooved  
V-Grooved  
056 192  
056 192  
056 192  
056 206  
.030 in  
.035 in  
.030 in  
.035 in  
056 206  
056 206  
.040 in  
.045 in  
.052 in  
1/16 in  
.040 in  
.045 in  
.052 in  
.062 in  
1.0 mm  
1.2 mm  
1.3 mm  
1.6 mm  
191 917  
046 782  
046 783  
046 784  
053 696  
053 697  
053 698  
053 699  
V-Grooved  
V-Grooved  
V-Grooved  
V-Grooved  
056 192  
056 193  
056 193  
056 195  
056 206  
056 207  
056 207  
056 209  
.035 in  
.045 in  
.052 in  
.035 in  
.045 in  
.052 in  
0.9 mm  
1.2 mm  
1.3 mm  
044 750  
046 785  
046 786  
072 000  
053 701  
053 702  
U-Grooved  
U-Grooved  
U-Grooved  
056 192  
056 193  
056 193  
056 206  
056 207  
056 207  
1/16 in  
5/64 in  
.062 in  
.079 in  
1.6 mm  
2.0 mm  
046 787  
046 788  
053 706  
053 704  
U-Grooved  
U-Grooved  
056 195  
056 195  
056 209  
056 209  
.035 in  
.045 in  
.052 in  
1/16 in  
.035 in  
.045 in  
.052 in  
.062 in  
0.9 mm  
1.2 mm  
1.3 mm  
1.6 mm  
046 792  
046 793  
046 794  
046 795  
132 958  
132 957  
132 956  
132 955  
V-Knurled  
V-Knurled  
V-Knurled  
V-Knurled  
056 192  
056 193  
056 193  
056 195  
056 206  
056 207  
056 207  
056 209  
.068-.072 in .068-.072 in 1.8 mm  
089 985  
046 796  
132 959  
132 960  
V-Knurled  
V-Knurled  
056 195  
056 195  
056 209  
056 209  
5/64 in  
.079 in  
2.0 mm  
.045 in  
.052 in  
1/16 in  
5/64 in  
.045 in  
.052 in  
.062 in  
.079 in  
1.2 mm  
1.3 mm  
1.6 mm  
2.0 mm  
083 319  
083 320  
046 800  
046 801  
083 489  
083 490  
053 708  
053 710  
U-Cogged  
U-Cogged  
U-Cogged  
U-Cogged  
056 193  
056 193  
056 195  
056 195  
056 207  
056 207  
056 209  
056 209  
Ref. S-0025-D  
OM-186 895 Page 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
OM-186 895 Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
OM-186 895 Page 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Effective January 1, 1999  
(Equipment with a serial number preface of “KK” or newer)  
Warranty Questions?  
Call  
1-800-4-A-MILLER  
for your local  
Miller distributor.  
This limited warranty supersedes all previous Miller warranties and is exclusive with no other  
guarantees or warranties expressed or implied.  
LIMITED WARRANTY Subject to the terms and conditions  
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants  
to its original retail purchaser that new Miller equipment sold  
after the effective date of this limited warranty is free of defects  
in material and workmanship at the time it is shipped by Miller.  
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE  
WARRANTIES OF MERCHANTABILITY AND FITNESS.  
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting  
Torches  
*
*
*
*
Remote Controls  
Accessory Kits  
Replacement Parts (No labor)  
Spoolmate 185  
Your distributor also gives  
you ...  
Within the warranty periods listed below, Miller will repair or  
replace any warranted parts or components that fail due to  
such defects in material or workmanship. Miller must be  
notified in writing within thirty (30) days of such defect or  
failure, at which time Miller will provide instructions on the  
warranty claim procedures to be followed.  
Miller’s True Blue® Limited Warranty shall not apply to:  
Service  
1. Items furnished by Miller, but manufactured by others,  
such as engines or trade accessories. These items are  
covered by the manufacturer’s warranty, if any.  
You always get the fast,  
reliable response you  
need. Most replacement  
parts can be in your  
hands in 24 hours.  
2. Consumable components; such as contact tips, cutting  
nozzles, contactors, brushes, slip rings, relays or parts  
that fail due to normal wear.  
Miller shall honor warranty claims on warranted equipment  
listed below in the event of such a failure within the warranty  
time periods. All warranty time periods start on the date that  
the equipment was delivered to the original retail purchaser, or  
one year after the equipment is sent to a North American  
distributor or eighteen months after the equipment is sent to an  
International distributor.  
Support  
3. Equipment that has been modified by any party other  
than Miller, or equipment that has been improperly  
installed, improperly operated or misused based upon  
industry standards, or equipment which has not had  
reasonable and necessary maintenance, or equipment  
which has been used for operation outside of the  
specifications for the equipment.  
Need fast answers to the  
tough welding questions?  
Contact your distributor.  
The expertise of the  
distributor and Miller is  
there to help you, every  
step of the way.  
1. 5 Years Parts 3 Years Labor  
*
*
Original main power rectifiers  
Inverters (input and output rectifiers only)  
MILLER PRODUCTS ARE INTENDED FOR PURCHASE  
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND  
PERSONS TRAINED AND EXPERIENCED IN THE USE  
AND MAINTENANCE OF WELDING EQUIPMENT.  
2. 3 Years — Parts and Labor  
*
*
*
*
*
*
Transformer/Rectifier Power Sources  
Plasma Arc Cutting Power Sources  
Semi-Automatic and Automatic Wire Feeders  
Inverter Power Supplies  
In the event of a warranty claim covered by this warranty, the  
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)  
replacement; or, where authorized in writing by Miller in  
appropriate cases, (3) the reasonable cost of repair or  
replacement at an authorized Miller service station; or (4)  
payment of or credit for the purchase price (less reasonable  
depreciation based upon actual use) upon return of the goods  
at customer’s risk and expense. Miller’s option of repair or  
replacement will be F.O.B., Factory at Appleton, Wisconsin, or  
F.O.B. at a Miller authorized service facility as determined by  
Miller. Therefore no compensation or reimbursement for  
transportation costs of any kind will be allowed.  
Intellitig  
Engine Driven Welding Generators  
(NOTE: Engines are warranted separately by the  
engine manufacturer.)  
3. 1 Year — Parts and Labor  
*
Motor Driven Guns (w/exception of Spoolmate  
185)  
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES  
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE  
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR  
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR  
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF  
PROFIT), WHETHER BASED ON CONTRACT, TORT OR  
ANY OTHER LEGAL THEORY.  
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Process Controllers  
Positioners and Controllers  
Automatic Motion Devices  
Robots  
IHPS Power Sources  
Water Coolant Systems  
HF Units  
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN  
AND ANY IMPLIED WARRANTY, GUARANTY OR  
REPRESENTATION AS TO PERFORMANCE, AND ANY  
REMEDY FOR BREACH OF CONTRACT TORT OR ANY  
OTHER LEGAL THEORY WHICH, BUT FOR THIS  
Grids  
Spot Welders  
PROVISION,  
MIGHT  
ARISE  
BY  
IMPLICATION,  
Load Banks  
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE  
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR PARTICULAR  
PURPOSE, WITH RESPECT TO ANY AND ALL  
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND  
DISCLAIMED BY MILLER.  
SDX Transformers  
Miller Cyclomatic Equipment  
Running Gear/Trailers  
Plasma Cutting Torches (except APT, ZIPCUT &  
PLAZCUT Models)  
Some states in the U.S.A. do not allow limitations of how long  
an implied warranty lasts, or the exclusion of incidental,  
indirect, special or consequential damages, so the above  
limitation or exclusion may not apply to you. This warranty  
provides specific legal rights, and other rights may be  
available, but may vary from state to state.  
*
*
Deutz Engines (outside North America)  
Field Options  
(NOTE: Field options are covered under True  
Blue® for the remaining warranty period of the  
product they are installed in, or for a minimum of  
one year — whichever is greater.)  
In Canada, legislation in some provinces provides for certain  
additional warranties or remedies other than as stated herein,  
and to the extent that they may not be waived, the limitations  
and exclusions set out above may not apply. This Limited  
Warranty provides specific legal rights, and other rights may  
be available, but may vary from province to province.  
4. 6 Months — Batteries  
5. 90 Days — Parts  
*
MIG Guns/TIG Torches  
miller_warr 1/99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owner’s Record  
Please complete and retain with your personal records.  
Model Name  
Purchase Date  
Distributor  
Address  
Serial/Style Number  
(Date which equipment was delivered to original customer.)  
City  
State  
Zip  
Resources Available  
Always provide Model Name and Serial/Style Number.  
Contact your Distributor for:  
Welding Supplies and Consumables  
Options and Accessories  
Personal Safety Equipment  
Service and Repair  
To locate distributor nearest you call  
1-800-4-A-Miller.  
Miller Electric Mfg. Co.  
An Illinois Tool Works Company  
1635 West Spencer Street  
Appleton, WI 54914 USA  
Replacement Parts  
Training (Schools, Videos, Books)  
International HeadquartersUSA  
USA Phone: 920-735-4505 Auto-Attended  
USA & Canada FAX: 920-735-4134  
International FAX: 920-735-4125  
Technical Manuals (Servicing Information  
and Parts)  
Circuit Diagrams  
European Headquarters −  
United Kingdom  
Phone: 44 (0) 1204-593493  
FAX: 44 (0) 1204-598066  
Welding Process Handbooks  
www.MillerWelds.com  
Contact the Delivering Carrier for:  
File a claim for loss or damage during  
shipment.  
For assistance in filing or settling claims,  
contact your distributor and/or equipment  
manufacturer’s Transportation Department.  
PRINTED IN USA  
© 1999 Miller Electric Mfg. Co. 9/98  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Milwaukee Drill Diamond Drill User Manual
MSi Computer Hardware MS 7304 User Manual
MTD Trimmer 710 700 User Manual
Nady Systems Stereo Equalizer PEQ 5B User Manual
NEC Network Router 750370 User Manual
New Transducers Computer Monitor TR 5001 User Manual
Nikon Camera Accessories SB 28 User Manual
NuTone Answering Machine VSM4RK User Manual
Omega Vehicle Security Home Security System 850i User Manual
Palsonic Flat Panel Television TFTV435WS User Manual