OM-186 895G
June 1999
Processes
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
Description
Wire Feeder
I-22A & I-24A
Visit our website at
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . .
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 1 − CONSIGNES DE SECURITE − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
3
3
4
5
5
5
WARNING
This product, when used
for welding or cutting,
produces fumes or
gases which contain
chemicals known to the
State of California to
cause birth defects and,
in some cases, cancer.
(California Health &
Safety Code Section
25249.5 et seq.)
1-3 Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
8
8
9
9
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Rating Label For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10
10
SECTION 3 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Site Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Gun Recommendation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. Equipment Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5. 14-Pin Receptacle, Shielding Gas And Optional Volt Sense Lead . . . . . . . . . . . . . . . . . . . . . .
3-6. 14-Pin Receptacle Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7. Connecting Welding Gun And Weld Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-8. Optional Meter Circuit Board Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-9. Motor Start/Burnback Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-10.Installing Wire Guide And Drive Roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-11.Installing And Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
11
12
12
12
13
13
14
15
16
17
SECTION 4 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4-1. Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Optional Side Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
19
SECTION 5 − MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Overload Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
20
20
SECTION 6 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
SECTION 7 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
OPTIONS AND ACCESSORIES
WARRANTY
OM-186 895
Download from Www.Somanuals.com. All Manuals Search And Download.
Declaration of Conformity for
European Community (CE) Products
This information is provided for units with CE certification (see rating label on unit).
NOTE
Manufacturer’s Name:
Miller Electric Mfg. Co.
1635 W. Spencer Street
Appleton, WI 54914 USA
Manufacturer’s Address:
Declares that the product:
I-22A And I-24A
conforms to the following Directives and Standards:
Directives
Low Voltage Directive: 73/23/EEC
Electromagnetic Compatibility (EMC) Directive: 89/336/EEC
Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC
Standards
Arc Welding Equipment Part I: Welding Power Sources: IEC 974-1
(April 1995 − Draft Revision)
Arc Welding Equipment: Wirefeed Systems: IEC 974-4
(May 1995 − Draft Revision)
Degrees of Protection Provided By Enclosures (IP Code): IEC 529:1989
Insulation Coordination For Equipment With Low-Voltage Systems:
Part I: Principles, Requirements and Tests: IEC 664-1: 1992
Electromagnetic Compatibility, (EMC): EN 50199
European Contact:
Mr. Luigi Vacchini, Managing Director
MILLER Europe S.P.A.
Via Privata Iseo
20098 San Giuliano
Milanese, Italy
Telephone:
Fax:
39(02)98290-1
39(02)98281-552
dec_con1 1/96
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING
som _nd_5/97
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
Y
Marks a special safety message.
. Means “Note”; not safety related.
1-2. Arc Welding Hazards
Y
The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
Safety Standards.
D
D
D
If earth grounding of the workpiece is required, ground it directly
with a separate cable − do not use work clamp or work cable.
Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D
D
D
Wear a safety harness if working above floor level.
Keep all panels and covers securely in place.
Y
Y
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D
D
Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
ELECTRIC SHOCK can kill.
Do not connect more than one electrode or work cable to any
single weld output terminal.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
SIGNIFICANT DC VOLTAGE exists after removal of
input power on inverters.
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
groundedequipment is a hazard.
D
Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
D
D
D
Do not touch live electrical parts.
Wear dry, hole-free insulating gloves and body protection.
FUMES AND GASES can be hazardous.
Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D
Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D
D
Keep your head out of the fumes. Do not breathe the fumes.
D
D
Use AC output ONLY if required for the welding process.
If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
If AC output is required, use remote output control if present on
unit.
D
D
If ventilation is poor, use an approved air-supplied respirator.
D
Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
Read the Material Safety Data Sheets (MSDSs) and the
manufacturer’s instructions for metals, consumables, coatings,
cleaners, and degreasers.
D
D
Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D
Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch-
person nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breath-
ing air is safe.
Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
groundedreceptacle outlet.
D
D
Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D
D
When making input connections, attach proper grounding conduc-
tor first − double-check connections.
Frequently inspect input power cord for damage or bare wiring −
replace cord immediately if damaged − bare wiring can kill.
Do not weld on coated metals, such as galvanized, lead, or
cadmiumplated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-suppliedrespirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.
D
D
D
Turn off all equipment when not in use.
Do not use worn, damaged, undersized, or poorly spliced cables.
Do not drape cables over your body.
OM-186 895 Page 1
Download from Www.Somanuals.com. All Manuals Search And Download.
ARC RAYS can burn eyes and skin.
BUILDUP OF GAS can injure or kill.
D
D
Shut off shielding gas supply when not in use.
Always ventilate confined spaces or use
approved air-supplied respirator.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D
Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes when welding or watching (see ANSI Z49.1
and Z87.1 listed in Safety Standards).
HOT PARTS can cause severe burns.
D
D
D
Wear approved safety glasses with side shields under your
helmet.
D
D
Do not touch hot parts bare handed.
Allow cooling period before working on gun or
torch.
Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
Wear protective clothing made from durable, flame-resistant mate-
rial (leather and wool) and foot protection.
MAGNETIC FIELDS can affect pacemakers.
WELDING can cause fire or explosion.
D
D
Pacemaker wearers keep away.
Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
NOISE can damage hearing.
D
D
D
Protect yourself and others from flying sparks and hot metal.
Do not weld where flying sparks can strike flammable material.
Noise from some processes or equipment can
damagehearing.
Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D
Wear approved ear protection if noise level is
high.
D
Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D
D
Watch for fire, and keep a fire extinguisher nearby.
CYLINDERS can explode if damaged.
Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D
D
Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
D
D
Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, slag, open flames, sparks, and arcs.
Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D
D
Do not use welder to thaw frozen pipes.
Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D
D
D
D
D
Keep cylinders away from any welding or other electrical circuits.
Never drape a welding torch over a gas cylinder.
D
D
Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
Never allow a welding electrode to touch any cylinder.
Never weld on a pressurized cylinder − explosion will result.
Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
Use only correct shielding gas cylinders, regulators, hoses, and fit-
tings designed for the specific application; maintain them and
associated parts in good condition.
FLYING METAL can injure eyes.
D
D
Turn face away from valve outlet when opening cylinder valve.
D
Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D
Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.
D
Wear approved safety glasses with side
shields even under your welding helmet.
OM-186 895 Page 2
Download from Www.Somanuals.com. All Manuals Search And Download.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
MOVING PARTS can cause injury.
D
Do not install or place unit on, over, or near
combustiblesurfaces.
Do not install unit near flammables.
D
D
Keep away from moving parts such as fans.
Keep all doors, panels, covers, and guards
closed and securely in place.
D
D
Do not overload building wiring − be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING UNIT can cause injury.
H.F. RADIATION can cause interference.
D
D
D
Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
Use equipment of adequate capacity to lift and
support unit.
If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
D
High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communicationsequipment.
D
Have only qualified persons familiar with
electronic equipment perform this installation.
D
D
The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa-
tion.
If notified by the FCC about interference, stop using the
equipmentat once.
OVERUSE can cause OVERHEATING
D
D
Allow cooling period; follow rated duty cycle.
Reduce current or reduce duty cycle before
starting to weld again.
D
D
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
D
Do not block or filter airflow to unit.
STATIC (ESD) can damage PC boards.
D
Put on grounded wrist strap BEFORE handling
boards or parts.
ARC WELDING can cause interference.
D
Use proper static-proof bags and boxes to
store, move, or ship PC boards.
D
Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
MOVING PARTS can cause injury.
D
Be sure all equipment in the welding area is
electromagneticallycompatible.
D
D
Keep away from moving parts.
Keep away from pinch points such as drive
rolls.
D
D
D
D
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
WELDING WIRE can cause injury.
Be sure this welding machine is installed and grounded
according to this manual.
D
Do not press gun trigger until instructed to do
so.
Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
D
1-4. Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face
Protection, ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018.
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-
dent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practices for the Preparation for Weldingand Cut-
ting of Containers That Have Held Hazardous Substances, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
OM-186 895 Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
1-5. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
Welding current, as it flows through welding cables, will cause electro-
magnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to power-
frequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined.Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
4. Keep welding power source and cables as far away from opera-
tor as practical.
5. Connect work clamp to workpiece as close to the weld as possi-
ble.
About Pacemakers:
To reduce magnetic fields in the workplace, use the following
procedures:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
OM-186 895 Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1 − CONSIGNES DE SECURITE − LIRE AVANT
UTILISATION
som _nd_fre 5/97
1-1. Signification des symboles
SignifieMise en garde ! Soyez vigilant ! Cette procédure
présente des risques de danger ! Ceux-ci sont identifiés
par des symboles adjacents aux directives.
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles
et aux directives ci-dessous afin de connaître les mesures à prendre pour
éviter tout danger.
Y
Identifie un message de sécurité particulier.
. Signifie NOTA ; n’est pas relatif à la sécurité.
1-2. Dangers relatifs au soudage à l’arc
Y
Les symboles présentés ci-après sont utilisés tout au long du
présent manuel pour attirer votre attention et identifier les risques
de danger. Lorsque vous voyez un symbole, soyez vigilant et
suivez les directives mentionnées afin d’éviter tout danger. Les
consignes de sécurité présentées ci-après ne font que résumer
l’information contenue dans les normes de sécurité énumérées
sécurité.
D
D
Ne pas toucher l’électrode quand on est en contact avec la pièce, la
terre ou une électrode provenant d’une autre machine.
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-le-
champ les pièces endommagées. Entretenir l’appareil conformément
à ce manuel.
D
D
D
Porter un harnais de sécurité quand on travaille en hauteur.
Maintenir solidement en place tous les panneaux et capots.
Y
Y
L’installation, l’utilisation, l’entretien et les réparations ne doi-
vent être confiés qu’à des personnes qualifiées.
Fixer le câble de retour de façon à obtenir un bon contact métal-métal
avec la pièce à souder ou la table de travail, le plus près possible de la
soudure.
Au cours de l’utilisation, tenir toute personne à l’écart et plus par-
ticulièrement les enfants.
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact
avec tout objet métallique.
UN CHOC ÉLECTRIQUE peut tuer.
Un simple contact avec des pièces électriques peut
provoquer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension
dès que l’appareil est sur ON. Le circuit d’entrée et les
circuits internes de l’appareil sont également sous
Il y a DU COURANT CONTINU IMPORTANT dans les
convertisseurs après la suppression de l’alimenta-
tion électrique.
D
Arrêter les convertisseurs, débrancher le courant électrique, et dé-
charger les condensateurs d’alimentation selon les instructions
indiquées dans la partie entretien avant de toucher les pièces.
tension à ce moment-là. En soudage semi-automatique ou automatique,
le fil, le dévidoir, le logement des galets d’entraînement et les pièces
métalliques en contact avec le fil de soudage sont sous tension. Des
matériels mal installés ou mal mis à la terre présentent un danger.
D
D
Ne jamais toucher les pièces électriques sous tension.
Porter des gants et des vêtements de protection secs ne comportant
pas de trous.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
D
S’isoler de la pièce et de la terre au moyen de tapis ou d’autres
moyens isolants suffisamment grands pour empêcher le contact phy-
sique éventuel avec la pièce ou la terre.
Ne pas se servir de source électrique àcourant électrique dans les zones
humides, dans les endroits confinés ou là où on risque de tomber.
Se servir d’une source électrique àcourant électrique UNIQUEMENT si le
procédé de soudage le demande.
Si l’utilisation d’une source électrique àcourant électrique s’avère néces-
saire, se servir de la fonction de télécommande si l’appareil en est équipé.
Couper l’alimentation ou arrêter le moteur avant de procéder à l’instal-
lation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de
sécurité).
Installer et mettre à la terre correctement cet appareil conformément à
son manuel d’utilisation et aux codes nationaux, provinciaux et
municipaux.
Toujours vérifier la terre du cordon d’alimentation − Vérifier et s’assu-
rer que le fil de terre du cordon d’alimentation est bien raccordé à la
borne de terre du sectionneur ou que la fiche du cordon est raccordée
à une prise correctement mise à la terre.
En effectuant les raccordements d’entrée fixer d’abord le conducteur
de mise à la terre approprié et contre-vérifier les connexions.
Le soudage génère des fumées et des gaz. Leur
inhalation peut être dangereux pour votre santé.
D
D
D
D
D
Eloigner votre tête des fumées. Ne pas respirer
les fumées.
D
A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau
de l’arc pour l’évacuation des fumées et des gaz de soudage.
D
D
Si la ventilation est insuffisante, utiliser un respirateur à alimenta-
tion d’air homologué.
Lire les spécifications de sécurité des matériaux (MSDSs) et les
instructions du fabricant concernant les métaux, les consomma-
bles, les revêtements, les nettoyants et les dégraisseurs.
Travailler dans un espace fermé seulement s’il est bien ventilé ou en
portant un respirateur à alimentation d’air. Demander toujours à un
surveillant dûment formé de se tenir à proximité. Des fumées et des
gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxy-
gène provoquant des blessures ou des accidents mortels. S’assu-
rer que l’air de respiration ne présente aucun danger.
Ne pas souder dans des endroits situés à proximité d’opérations de
dégraissage, de nettoyage ou de pulvérisation. La chaleur et les
rayons de l’arc peuvent réagir en présence de vapeurs et former des
gaz hautement toxiques et irritants.
D
D
D
D
D
D
D
Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas
endommagé ou dénudé − remplacer le cordon immédiatement s’il est
endommagé − un câble dénudé peut provoquer une électrocution.
Mettre l’appareil hors tension quand on ne l’utilise pas.
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffi-
sante ou mal épissés.
Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revête-
ment n’ait été enlevé dans la zone de soudure, que l’endroit soit bien
ventilé, et si nécessaire, en portant un respirateur à alimentation
d’air. Les revêtements et tous les métaux renfermant ces éléments
peuvent dégager des fumées toxiques en cas de soudage.
D
D
D
D
Ne pas enrouler les câbles autour du corps.
Si la pièce soudée doit être mise à la terre, le faire directement avec un
câble distinct − ne pas utiliser le connecteur de pièce ou le câble de
retour.
OM-186 895 Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
LES RAYONS DE L’ARC peuvent pro-
voquer des brûlures dans les yeux et
sur la peau.
LES ACCUMULATIONS DE GAZ ris-
quent de provoquer des blessures ou
même la mort.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intenses
(ultraviolets et infrarouges) susceptibles de provoquer
des brûlures dans les yeux et sur la peau. Des étincelles sont projetées
pendant le soudage.
D
Fermer l’alimentation du gaz protecteur en cas de
non utilisation.
D
Veiller toujours à bien aérer les espaces confinés ou se servir d’un respi-
rateur d’adduction d’air homologué.
D
Porter un casque de soudage muni d’un écran de filtre approprié pour
protéger votre visage et vos yeux pendant le soudage ou pour regar-
der (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
DES PIÈCES CHAUDES peuvent pro-
voquer des brûlures graves.
D
D
Porter des protections approuvés pour les oreilles si le niveau sondre est
trop élevé.
Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair
et de l’éblouissement; demander aux autres personnes de ne pas re-
garder l’arc.
D
D
Ne pas toucher des parties chaudes à mains nues
Prévoir une période de refroidissement avant
d’utiliser le pistolet ou la torche.
D
Porter des vêtements de protection constitué dans une matière dura-
ble, résistant au feu (cuir ou laine) et une protection des pieds.
LE SOUDAGE peut provoquer un
incendie ou une explosion.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent être
projetées de l’arc de soudure. La projection d’étincel-
D
D
Porteurs de stimulateur cardiaque, restez à distance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher
des opérations de soudage à l’arc, de gougeage ou
de soudage par points.
les, des pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec des
objets métalliques peut provoquer des étincelles, une explosion, un
surchauffement ou un incendie. Avant de commencer le soudage, vérifier
et s’assurer que l’endroit ne présente pas de danger.
D
D
D
Se protéger et d’autres personnes de la projection d’étincelles et de
métal chaud.
Ne pas souder dans un endroit là où des étincelles peuvent tomber sur
des substances inflammables.
Déplacer toutes les substances inflammables à une distance de 10,7
m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneuse-
ment avec des protections homologués.
Des étincelles et des matériaux chauds du soudage peuvent facile-
ment passer dans d’autres zones en traversant de petites fissures et
des ouvertures.
LE BRUIT peut affecter l’ouïe.
Le bruit des processus et des équipements peut affecter
l’ouïe.
D
Porter des protections approuvés pour les oreilles si
le niveau sondre est trop élevé.
D
D
D
D
Surveiller tout déclenchement d’incendie et tenir un extincteur à proxi-
mité.
Si des BOUTEILLES sont endomma-
gées, elles pourront exploser.
Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
Ne pas effectuer le soudage sur des conteneurs fermés tels que des
réservoirs, tambours, ou conduites, à moins qu’ils n’aient été prépa-
rés correctement conformément à AWS F4.1 (voir les normes de
sécurité).
Brancher le câble sur la pièce le plus près possible de la zone de sou-
dage pour éviter le transport du courant sur une longue distance par
des chemins inconnus éventuels en provoquant des risques d’élec-
trocution et d’incendie.
Des bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Si une bouteille est endomma-
gée, elle peut exploser. Du fait que les bouteilles de gaz
font normalement partie du procédé de soudage, les
manipuler avec précaution.
D
D
D
D
Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, du laitier, des flammes ouvertes, des étin-
celles et des arcs.
Placer les bouteilles debout en les fixant dans un support stationnai-
re ou dans un porte-bouteilles pour les empêcher de tomber ou de
se renverser.
Tenir les bouteilles éloignées des circuits de soudage ou autres cir-
cuits électriques.
Ne jamais placer une torche de soudage sur une bouteille à gaz.
Une électrode de soudage ne doit jamais entrer en contact avec une
D
D
D
Ne pas utiliser le poste de soudage pour dégeler des conduites ge-
lées.
En cas de non utilisation, enlever la baguette d’électrode du porte-
électrode ou couper le fil à la pointe de contact.
Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans re-
vers, des chaussures hautes et un couvre chef.
D
D
bouteille.
D
Avant de souder, retirer toute substance combustible de vos poches
telles qu’un allumeur au butane ou des allumettes.
D
D
Ne jamais souder une bouteille pressurisée − risque d’explosion.
Utiliser seulement des bouteilles de gaz protecteur, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la
bouteille.
Maintenir le chapeau de protection sur la soupape, sauf en cas d’uti-
lisation ou de branchement de la bouteille.
Lire et suivre les instructions concernant les bouteilles de gaz com-
primé, les équipements associés et les publications P-1 CGA énu-
mérées dans les normes de sécurité.
DES PARTICULES VOLANTES
peuvent blesser les yeux.
D
D
D
D
Le soudage, l’écaillement, le passage de la pièce
à la brosse en fil de fer, et le meulage génèrent
des étincelles et des particules métalliques vo-
lantes. Pendant la période de refroidissement des soudures, elles ris-
quent de projeter du laitier.
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.
OM-186 895 Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D
Ne pas placer l’appareil sur, au-dessus ou à proxi-
mité de surfaces infllammables.
D
Rester à l’écart des organes mobiles comme le
ventilateur.
D
Maintenir fermés et fixement en place les portes,
panneaux, recouvrements et dispositifs de
protection.
D
D
Ne pas installer l’appareil à proximité de produits inflammables
Ne pas surcharger l’installation électrique − s”assurer que l’alimen-
tation est correctement dimensionné et protégé avant de mettre
l’appareil en service.
LE RAYONNEMENT HAUTE FRÉ-
QUENCE (H.F.) risque de provoquer
des interférences.
LA CHUTE DE L’APPAREIL peut
blesser.
D
Le rayonnement haute frequence peut provoquer
des interférences avec les équipements de ra-
dio−navigationet de communication, les services
de sécurité et les ordinateurs.
D
Utiliser l’anneau de levage uniquement pour sou-
lever l’appareil, NON PAS les chariot, les bouteil-
les de gaz ou tout autre accessoire.
D
Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installa-
tion.
L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
D
Utiliser un engin d’une capacité appropriée pour
soulever l’appareil.
D
En utilisant des fourches de levage pour déplacer l’unité, s’assurer
que les fourches sont suffisamment longues pour dépasser du côté
opposé de l’appareil.
D
D
Si le FCC signale des interférences, arrêter immédiatement l’appa-
reil.
L’EMPLOI EXCESSIF peut
D
D
Effectuer régulièrement le contrôle et l’entretien de l’installation.
Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance
correcte et utiliser une terre et et un blindage pour réduire les interfé-
rences éventuelles.
SURCHAUFFER L’ÉQUIPEMENT.
D
Prévoir une période de refroidissement, respec-
ter le cycle opératoire nominal.
D
Réduire le courant ou le cycle opératoire avant de
recommancer le soudage.
LE SOUDAGE À L’ARC risque de
provoquer des interférences.
D
Ne pas obstruer les passages d’air du poste.
LES CHARGES ÉLECTROSTATI-
QUES peuvent endommager les cir-
cuits imprimés.
D
L’énergie électromagnétique risque de provoquer
des interférences pour l’équipement électronique
sensible tel que les ordinateurs et l’équipement
commandé par ordinateur tel que les robots.
D
D
Veiller à ce que tout l’équipement de la zone de soudage soit com-
D
Établir la connexion avec la barrette de terre
avant de manipuler des cartes ou des pièces.
Utiliser des pochettes et des boîtes antistatiques
pour stocker, déplacer ou expédier des cartes de
circuits imprimes.
patible électromagnétiquement.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser aussi
bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement
électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il
incombe à l’utilisateur de prendre des mesures supplémentaires tel-
les que le déplacement du poste, l’utilisation de câbles blindés, l’uti-
lisation de filtres de ligne ou la pose de protecteurs dans la zone de
travail.
D
D
D
D
DES ORGANES MOBILES peuvent
provoquer des blessures.
D
D
Ne pas s’approcher des organes mobiles.
Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
LES FILS DE SOUDAGE peuvent pro-
voquer des blessures.
D
D
Porteurs de stimulateur cardiaque, restez à dis-
tance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’appro-
cher des opérations de soudage à l’arc, de gou-
geage ou de soudage par points.
D
Ne pas appuyer sur la gachette avant d’en avoir
reçu l’instruction.
Ne pas diriger le pistolet vers soi, d’autres person-
nes ou toute pièce mécanique en engageant le fil
de soudage.
D
OM-186 895 Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
1-4. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
RecommendedSafe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
Safe Practices For Occupation And Educational Eye And Face Protec-
tion, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.
NationalElectrical Code, NFPA Standard 70, de la National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
1-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence
Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :
1
Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.
Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir ex-
aminé plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Re-
search Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiqueset champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les con-
clusions finales de la recherche soient établies, il vous serait
souhaitablede réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.
2
3
Mettre tous les câbles du côté opposé de l’opérateur.
Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.
4
5
Garder le poste de soudage et les câbles le plus loin possible de
vous.
Relier la pince de masse le plus près possible de la zone de
soudure.
Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes ci−dessus.
OM-186 895 Page 8
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 2 − DEFINITIONS
2-1. Warning Label Definitions
A. Warning! Watch Out! There
are possible hazards as
shown by the symbols.
B. Drive rolls can injure fingers.
A
B
C
C. Welding wire and drive parts
are at welding voltage during
operation − keep hands and
metal objects clear.
1
Electric shock can kill.
1.1 Wear dry insulating gloves.
Do not touch electrode with
bare hand. Do not wear wet or
damaged gloves.
1.2 Protect yourself from electric
shock by insulating yourself
from work and ground.
1
2
1.1
2.1
3.1
4.1
1.2
1.3
1.3 Disconnect input plug or
power before working on
machine.
2
Breathing welding fumes can
be hazardous to your health.
2.2
2.3
2.1 Keep your head out of the
fumes.
2.2 Use forced ventilation or local
exhaust to remove the fumes.
2.3 Use ventilating fan to remove
fumes.
3
4
5
3.2
3.3
3
Welding sparks can cause
explosion or fire.
3.1 Keep flammables away from
welding. Don’t weld near
flammables.
3.2 Welding sparks can cause
fires. Have a fire extinguisher
nearby and have a watch
person ready to use it.
+ + +
3.3 Do not weld on drums or any
closed containers.
4
Arc rays can burn eyes and
injure skin.
6
4.1 Wear hat and safety glasses.
Use ear protection and button
shirt collar. Use welding
helmet with correct shade of
filter. Wear complete body
protection.
+
S-178 936
5
Become trained and read the
instructions before working on
the machine or welding.
6
Do not remove or paint over
(cover) the label.
OM-186 895 Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
2-2. Rating Label For CE Products
S/N:
U1
I =
1
50/60 Hz
IP 23
24 V
1
=
7.0
A
U2
=
I =
500 A
2
100 V
X 100 %
178 794-A
2-3. Symbols And Definitions
Some symbols are found only on CE products.
NOTE
On
Off
Input
Output
Amperes
Volts
Hertz
AlternatingCurrent
Circuit Breaker
Duty Cycle
Wire Feed
A
IP
V
Hz
U1
X
Degree Of
Protection
Gas Metal Arc
Welding (GMAW)
Gun
Jog
Primary Voltage
Spot Weld Time
Line Connection
Continuous Weld
Purge
Spot Weld
Burnback Time
Load Voltage
Preflow Time
Postflow Time
Rated Current
Read Instructions
Primary Voltage
Primary Current
U2
I1
I2
U1
OM-186 895 Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 3 − INSTALLATION
3-1. Specifications
Welding
Type of Input
Power
Wire
Diameter
Range
Welding
Circuit
Rating
Wire Feed
Speed Range
IP
Rating
Overall
Dimensions
Weight
Power
Source Type
Length: 597 mm
(23-1/2 in)
0.6 To 2 mm
100 Volts,
500 Amperes,
100%
Constant Voltage
(.023 To 5/64 in)
24 Volts AC
(CV) DC With
Single Phase
14-Pin And
7 Amperes 50/60
Contactor
1.9 To 19 mpm
(75 to 750 ipm)
Width: 273 mm
(10-3/4 in)
IP 23
15.9 kg (35 lb)
Max Spool
Weight:
27 kg (60 lb)
Duty Cycle
Hz
Height: 279 mm
(11 in)
Control
3-2. Site Selection
1
Wire Feeder
Lifting Eye
Rubber Feet
Slot
2
3
4
5
6
1
Choose slot that allows all rubber
feet to sit securely on top of welding
power source.
7
5
6
Wire Spool/Reel
Gas Cylinder (Customer
Supplied)
7
Welding Power Source
Y
Do not put feeder where
welding wire hits cylinder.
Y
Do not move or operate
equipment when it could tip.
8
Lifting Handle
Y
Manuallyuse handle to move
or briefly lift feeder.
Y
Do not use lifting hook or
other devices to lift or
suspend feeder by the
handle.
2
4
3
8
801 920-C / Ref. 152 468-A / 155 242 / 801 919-C / 188 674
OM-186 895 Page 11
Download from Www.Somanuals.com. All Manuals Search And Download.
3-3. Gun Recommendation Table
Process
Gun
GMAW − Hard or Corded Wires
FCAW − Self-Shielding Wires
M25 Or M40
GA-40GL
3-4. Equipment Connection Diagrams
1
2
3
CV Welding Power Source
With 24 VAC Power
CV Welding Power Source
Without 24 VAC Power
115 Volts AC /24 Volts AC
Power Adapter
4
5
6
14-Pin Control Cord
Weld Cable (Required)
Work
1
4
6
3
5
2
115VAC
4
Contactor
6
5
3-5. 14-Pin Receptacle, Shielding Gas And Optional Volt Sense Lead
1
Gas Hose With 5/8-18 Right-
hand Thread Fittings (Cus-
tomer Supplied)
3
2
14 Pin Receptacle RC9
2
Use interconnecting cord to make
connection to welding power
source.
3
Power Switch
1
Tools Needed:
5/8, 11/16 in
801 921-C
OM-186 895 Page 12
Download from Www.Somanuals.com. All Manuals Search And Download.
3-6. 14-Pin Receptacle Information
Pin*
Pin Information
A
B
G
C
D
E
F
24 volts ac with respect to pin G.
Contact closure to A completes 24 volts ac contactor control circuit.
Circuit common for 24 volts AC circuit.
J
A
E
K
I
B
N
L
C
+10 volts dc output to remote control with respect to pin D.
Remote control circuit common.
H
M
F
D
G
0 to +10 volts dc input command signal from remote control with respect to pin D.
Current feedback; 0 to 10 volts dc, 1 V/100 A
H
Voltage feedback; 0 to 10 volts dc, 1 V/10 arc volts
*The remaining pins are not used.
Ref. S-0004-A
3-7. Connecting Welding Gun And Weld Cable
1
2
Gun/FeederAdapter
Gun Connector
Insert gun connector into adapter.
Tighten locking ring.
3
4
Weld Cable Terminal
Weld Cable From Welding
Power Source
1
2
4
3
Tools Needed:
9/16, 5/8 in
801 922-B
OM-186 895 Page 13
Download from Www.Somanuals.com. All Manuals Search And Download.
3-8. Optional Meter Circuit Board Settings
1
2
3
4
Meter Circuit Board
DIP Switch S2
Potentiometer R18
Receptacle RC16
Wiring harness with free-hanging
plug PLG42 connects to RC16.
For voltage feedback from voltage
sensing lead, connect plug PLG43
from unit wiring harness to PLG42.
For voltage feedback from welding
power source to wire feeder 14-pin
receptacle, connect plug PLG41
from unit wiring harness to PLG42.
1
2
1
2
X Means switch position does not affect
specified function.
.
Means switch must be in this position.
Voltage Sensing Function
Digital Meter Display
Arc Voltage Sensing Using Voltage Sensing
Lead For Welding Power Source That Does
Not Support Pins F And H
Meters/Minute
1
2
3
4
5
1
2
3
4
5
Or
Or
Inches/Minute
Arc Voltage Sensing Using Feedback From
Welding Power Source That Does Support
Pins F And H
1
2
3
4
5
1
2
3
4
5
Tools Needed:
1/4 in
801 925-C / Ref. 186 266
OM-186 895 Page 14
Download from Www.Somanuals.com. All Manuals Search And Download.
3-9. Motor Start/Burnback Control
To change wire feed starting speed
proceed as follows:
Turn Off unit and welding power
source.
1
Remove wrapper.
1
2
Motor Board PC1
Motor Start Control
Potentiometer R73
Remove protective white rubber
cap before making adjustment.
Adjust potentiometer R73 using a
small nonconductive screwdriver.
Rotate potentiometer clockwise to
increase time it takes the motor to
ramp up to speed.
3
Burnback Potentiometer R42
Remove protective white rubber
cap before making adjustment.
Adjust potentiometer R42 using a
small nonconductive screwdriver.
Rotate potentiometer clockwise to
increase burnback time.
2
Reinstall wrapper.
3
Tools Needed:
Non-Conductive
1/4 in
801 925-C / 192 653
OM-186 895 Page 15
Download from Www.Somanuals.com. All Manuals Search And Download.
3-10. Installing Wire Guide And Drive Roll
Install and secure inlet wire guide
on either assembly, and
intermediatewire guide on 4 drive
roll assembly only. Install drive rolls
and turn drive roll nut one click.
During maintenance intervals,
remove drive rolls, and clean
grooves using a wire brush. Check
groove of drive roll for pitting or
increase in the depth of the groove
indicating drive roll is worn out.
Tools Needed:
3/8 in
801 923-C
OM-186 895 Page 16
Download from Www.Somanuals.com. All Manuals Search And Download.
3-11. Installing And Threading Welding Wire
1
2
Retaining Ring
Hub Tension Adjustment Nut
If necessary, move hub on support
for use of different size wire spool.
Remove retaining ring, and install
spool so hub pin fits spool hole.
Reinstall retaining ring.
1
2
3
Adjust tension nut so wire is taut
when wire feed stops.
3
Pressure Assembly
Adjustment Knob
Lay gun cable out straight.
A
Open pressure assembly,
hold wire tightly, and cut off
end. Push wire through guides
into gun.
B
C
Close and tighten pressure
assembly. Press JOG button
until wire comes out gun.
To adjust drive roll pressure,
press gun trigger to feed wire
against wood surface. Tighten
knob so wire does not slip.
Cut off wire. Close door.
A
B
C
Tighten
WOOD
Tools Needed:
15/16 in
Ref. 801 924-B / S-0627-A
OM-186 895 Page 17
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 4 − OPERATION
4-1. Front Panel Controls
1
2
Optional Voltage/Wire Speed
Meter
1
Optional Voltage/Wire Speed
Switch
Use to choose volts or wire feed
speed display.
2
3
3
Optional Remote Voltage
Control
Use to set welding power source
voltage at the wire feeder. Numbers
are for reference only.
4
5
Wire Speed Control
Jog/Purge Switch
4
Use Jog position to momentarily
feed welding wire at speed set on
Wire Speed control without ener-
gizing welding circuit or shielding
gas valve.
Use Purge position to momentarily
energizegas valve to purge air from
gun or adjust gas regulator.
5
6
Trigger Hold Switch
Push up to weld without holding gun
trigger throughout the weld cycle.
To start weld cycle, press and re-
lease gun trigger within three se-
conds after an arc has been struck.
To end weld, press and release gun
trigger.
Power switch is on rear panel (see
6
Ref. 188 340-A
OM-186 895 Page 18
Download from Www.Somanuals.com. All Manuals Search And Download.
4-2. Optional Side Panel Controls
1
Preflow Control
Control sets time gas flows before
welding wire is energized. Time
range is 0 to 5 seconds.
1
2
Postflow Control
Control sets time gas flows after
completion of burnback. Time
range is 0 to 5 seconds.
3
Spot Time Control
2
Factory set for 0.25 to 5 seconds of
spot time. Rotating knob fully
counterclockwise
selects
an
untimed continuous weld.
Close side door.
3
Ref. 801 923-C / Ref. 186 589
SECTION 5 − MAINTENANCE & TROUBLESHOOTING
5-1. Routine Maintenance
Y
Disconnect power before maintaining.
3 Months
Repair Or
Replace
Cracked
Clean And
Tighten
Weld
Replace
Unreadable
Labels
Weld Cable
Terminals
Replace
Cracked
Parts
14-Pin Cord
Gun Cable
Gas Hose
6 Months
Blow Out Or Vacuum
Clean
Drive
Rolls
Inside,
OR
During Heavy Service,
Clean Monthly
OM-186 895 Page 19
Download from Www.Somanuals.com. All Manuals Search And Download.
5-2. Overload Protection
Y
Turn Off wire feeder and
welding power source. Stop
engine
on
welding
1
generator.
1
Circuit Breaker CB1
CB1 protects wire feeder from over-
load.
Correct problem and manually
reset breaker.
801 921-C
5-3. Troubleshooting
Trouble
Remedy
Wire does not feed, unit completely inop- Turn Power switch On.
erative.
Check 14−pin receptacle RC9 connections.
Check input power.
Wire does not feed.
Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s
Manual.
Have Factory Authorized Service Agent check drive motor and control board PC1.
Use correct size drive roll (see Parts List).
Wire feeds erratically.
Remove weld spatter around nozzle opening.
Replace contact tip or liner. See gun Owner’s Manual.
Have Factory Authorized Service Agent check drive motor and control board PC1.
Wire feeds when Jog switch is pressed Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s
but not when gun trigger is pressed. Manual.
Wire feeds as soon as power is applied. Check gun trigger. See gun Owner’s Manual.
Wire does not feed until trigger is Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads.
pressed but continues to feed after trig-
ger is released.
Gas valve rattles loudly and wire feeds Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads.
slowly or erratically.
Gas does not flow; wire feeds.
OM-186 895 Page 20
Check gas valve and flowmeter.
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 6 − ELECTRICAL DIAGRAM
186 738-B
Figure 6-1. Circuit Diagram For Wire Feeder With Optional Equipment
OM-186 895 Page 21
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 7 − PARTS LIST
7
8
6
9
10
11
12
3
13
2
12
11
1
5
14
4
15
16
21
50
23
22
49
24
17
20
48
19
18
51
53
52
25
26
47
27
28
46
29
30
45
32
33
34
35
39
40
31
41
36
42
37
43
23
38
44
. Hardware is common and
801 990-C
not available unless listed.
Figure 7-1. Main Assembly
OM-186 895 Page 22
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Dia.
Mkgs.
Part
No.
Description
Figure 7-1. Main Assembly
Quantity
. . . 1 . . . . . . . . . . . . . 089 899 . . . LATCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 2 . . . . . . . . . . . . +186 674 . . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 3 . . . . . . . . . . . . . 178 936 . . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 4 . . . . . . . . . . . . . 187 909 . . . HANDLE, lifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 604 423 . . . GRIP, handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 5 . . . . . . . . . . . . . 188 674 . . . LABEL, caution incorrect lifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 6 . . . . . . . . . . . . . 072 094 . . . HUB & SPINDLE ASSEMBLY, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 7 . . . . . . . . . . . . . 058 427 . . . . RING, retaining spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 8 . . . . . . . . . . . . . 180 572 . . . . SHAFT, spool support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 9 . . . . . . . . . . . . . 010 233 . . . . SPRING, cprsn .970 OD x .120 wire x 1.250 . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 10 . . . . . . . . . . . . . 057 971 . . . . WASHER, flat stl keyed 1.500dia x .125thk . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 11 . . . . . . . . . . . . . 010 191 . . . . WASHER, fbr .656 ID x 1.500 OD x .125thk . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 12 . . . . . . . . . . . . . 058 628 . . . . WASHER, brake stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 13 . . . . . . . . . . . . . 058 428 . . . . HUB, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 14 . . . . . . . . . . . . . 135 205 . . . . NUT, stl slflkg hex reg .625-11 w/nylon insert . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 15 . . . . . . . . . . . . . 137 461 . . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 16 . . . . . . . . . . . . . 134 306 . . . FOOT, rbr 1.250dia x 1.375 high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . 17 . . . . PC1 . . . . 192 652 . . . CIRCUIT CARD, motor speed control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG1 . . . 115 093 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG3 . . . 115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG4 . . . 115 091 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG5 . . . 130 203 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 18 . . . . . . . . . . . . . 134 201 . . . STAND-OFF SUPPORT, PC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
. . . 19 . . . . . . . . . . . . . 131 181 . . . WIRE GUIDE & NUT (22A Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 20 . . . . PC3 . . ♦186 297 . . . CIRCUIT CARD, timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . ♦098 691 . . . STAND-OFF, No 6-32 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG1 . ♦115 093 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . PLG3 . ♦135 409 . . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG33 . ♦115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG51 . ♦115 091 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 21 . . . . . . . . . . . ♦176 518 . . . FITTING, pipe brs elb 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 22 . . . . . . . . . . . ♦188 408 . . . FITTING, barb flow switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 23 . . . . . . . . . . . ♦188 442 . . . WASHER, shldr .515 ID 1.000 OD x .094thk . . . . . . . . . . . . . . . . . . . . . . . . . 8
. . . 24 . . . . . . . . . . . ♦163 603 . . . SWITCH, flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 25 . . . . . . . . . . . ♦601 881 . . . NUT, .500-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 26 . . . . S1 . . . . . 111 997 . . . SWITCH, rocker SPST 10A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 27 . . . . . . . . . . . . . 112 863 . . . FITTING, hose brs barbed M 1/4tbg x 5/8-18 SAE . . . . . . . . . . . . . . . . . . . . 1
. . . 28 . . . . . . . . . . . ♦126 693 . . . CABLE, sensing 15ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 29 . . . . . . . . . . . . . 605 227 . . . NUT, nyl hex jam .750NPST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 30 . . . . CB1 . . . . 161 078 . . . CIRCUIT BREAKER, man reset 1P 7A 250VAC . . . . . . . . . . . . . . . . . . . . . . 1
. . . 31 . . . . M1 . . . . 193 188 . . . MOTOR, gear 24VDC 146RPM (consisting of) . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . *136 745 . . . . BRUSH & SPRING ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 32 . . . . GS1 . . . . 125 785 . . . VALVE, 24VAC 2 way custom port 1/8 orf . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 33 . . . . RC9 . . . . 152 492 . . . RECEPTACLE W/PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 34 . . . . R1 . . . . . 073 562 . . . POTENTIOMETER, C sltd sft1/T 2W 10K ohm . . . . . . . . . . . . . . . . . . . . . . 1
. . . 35 . . . . R50 . . ♦035 897 . . . POTENTIOMETER, C sltd sft1/T 2W 1K linear . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 36 . . . . S2 . . . . . 134 846 . . . SWITCH, tgl SPTT 6A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 37 . . . . S3 . . . . . 134 847 . . . SWITCH, tgl SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 187 577 . . . COVER, opening meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . ♦133 644 . . . FRAME, snap-in switch rocker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 38 . . . . PC2 . . ♦186 268 . . . CIRCUIT CARD, meter (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . LCD1 . . . 181 355 . . . . METER, digital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG15 . ♦115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . PLG16 . ♦131 055 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . ♦115 443 . . . STAND-OFF, 6-32 x .750 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
OM-186 895 Page 23
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
Figure 7-1. Main Assembly (Continued)
. . . 39 . . . . . . . . . . . . . 192 955 . . . CASE ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 40 . . . LED1 . ♦179 203 . . . LED, 5100 2.0V 20MA green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 41 . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE (order by model and serial number) . . . . . . . . . . . . . . . . . . . . 1
. . . 42 . . . . . . . . . . . . . 097 924 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 43 . . . . . . . . . . . ♦097 924 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 44 . . . . . . . . . . . ♦162 736 . . . FITTING, pipe brs qdisc fem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . . . . . . . . . . . . . . ♦082 367 . . . FITTING, brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . ♦188 428 . . . HOSE, water 15.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . ♦188 429 . . . HOSE, water 25.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 45 . . . . . . . . . . . . . 187 246 . . . ADAPTER, gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 46 . . . . . . . . . . . . . 178 937 . . . LABEL, warning electric shock and pinch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 47 . . . . . . . . . . . . . 192 875 . . . PLATE, insulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 48 . . . . . . . . Fig 7-2 & 7-3 . . . WIRE DRIVE ASSEMBLIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 49 . . . . . . . . . . . . . 188 149 . . . GUIDE, wire inlet(consisting of) (4 drive roll) . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 50 . . . . . . . . . . . . . 082 050 . . . . LINER, monocoil inlet wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 082 036 . . . . GUIDE, wire inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 187 421 . . . TUBE, guide .030-.035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . 187 422 . . . TUBE, guide .045-.062 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 51 . . . . . . . . . . . . . 010 291 . . . WASHER, flat .625 x 1.250 OD x .125thk nylafil (22A Model) . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . ♦191 002 . . . KIT, gun connection (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . RC2 . . . . 048 282 . . . . RECEPTACLE w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 52 . . . . . . . . . . . ♦093 551 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . 53 . . . . . . . . . . . ♦186 587 . . . PLATE, control timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
♦OPTIONAL
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-186 895 Page 24
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
. . . 1 . . . . . . . . . . . . . 602 009 . . . SCREW, .250-20 x 1.250 soc hd hex gr 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 2 . . . . . . . . . . . . . 172 075 . . . CARRIER, drive roll w/component 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 3 . . . . . . . . . . . . . 054 263 . . . SCREW, thumb stl .250-20 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 4 . . . . . . . . . . . . . 010 224 . . . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 5 . . . . . . . . . . . . . 166 072 . . . SPACER, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 6 . . . . . . . . . . . . . 089 562 . . . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 7 . . . . . . . . . . . . . 085 244 . . . WASHER, cupped stl .328 ID x .812 OD x .125 . . . . . . . . . . . . . . . . . . . . . . 1
. . . 8 . . . . . . . . . . . . . 089 477 . . . SPRING, cprsn .770 OD x .105 wire x 1.225 . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 9 . . . . . . . . . . . . . 085 243 . . . KNOB, adjustment tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 10 . . . . . . . . . . . . . 166 071 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 11 . . . . . . . . . . . . . 151 828 . . . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 12 . . . . . . . . . . . . . 079 634 . . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 13 . . . . . . . . . . . . . 144 172 . . . FITTING, hose brs barbed m 3/16 tbg x .250-20 . . . . . . . . . . . . . . . . . . . . . . 1
. . . 14 . . . . . . . . . . . . . 172 391 . . . HOUSING, adapter gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 15 . . . . . . . . . . . . . 048 449 . . . WASHER, shldr nyl .363 OD x .194 ID x .703 . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 16 . . . . . . . . . . . . . 124 778 . . . KNOB, T 2.000 bar w/.312-18 x 1.000lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 17 . . . . . . . . . . . . . 605 308 . . . RING, rtng ext .500 shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 18 . . . . . . . . . . . . . 079 625 . . . WASHER, wave .500 ID x .750 OD x .015thk . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 19 . . . . . . . . . . . . . 121 271 . . . SCREW, .250-20 x .500 soc hd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 20 . . . . . . . . . . . . . 172 076 . . . CARRIER, drive roll w/components 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 21 . . . . . . . . . . . . . 092 865 . . . KEY, stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
9
8
7
10
12
11
6
5
4
3
2
1
13
14
21
20
15
19
16
17
18
802 019-A
Figure 7-2. Drive Assembly, Wire (2 Drive Roll )
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-186 895 Page 25
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
No.
Dia.
Mkgs.
Part
No.
Description
Quantity
. . . 1 . . . . . . . . . . . . . 602 009 . . . SCREW, .250-20 x 1.250 soc hd hex gr 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . 2 . . . . . . . . . . . . . 172 075 . . . CARRIER, drive roll w/component 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . 3 . . . . . . . . . . . . . 166 072 . . . SPACER, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . 4 . . . . . . . . . . . . . 054 263 . . . SCREW, thumb stl .250-20 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 5 . . . . . . . . . . . . . 010 224 . . . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 6 . . . . . . . . . . . . . 089 562 . . . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 7 . . . . . . . . . . . . . 085 244 . . . WASHER, cupped stl .328 ID x .812 OD x .125 . . . . . . . . . . . . . . . . . . . . . . 2
. . . 8 . . . . . . . . . . . . . 089 477 . . . SPRING, cprsn .770 OD x .105 wire x 1.225 . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 9 . . . . . . . . . . . . . 085 243 . . . KNOB, adjustment tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 10 . . . . . . . . . . . . . 166 071 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 11 . . . . . . . . . . . . . 079 634 . . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 12 . . . . . . . . . . . . . 151 828 . . . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 13 . . . . . . . . . . . . . 166 338 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 14 . . . . . . . . . . . . . 605 308 . . . RING, rtng ext .500 shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 15 . . . . . . . . . . . . . 187 325 . . . INSULATOR, drive assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 16 . . . . . . . . . . . . . 144 172 . . . FITTING, hose brs barbed m 3/16 tbg x .250-20 . . . . . . . . . . . . . . . . . . . . . . 1
. . . 17 . . . . . . . . . . . . . 166 337 . . . HOUSING, adapter gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 18 . . . . . . . . . . . . . 168 590 . . . BUSHING, insulating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 19 . . . . . . . . . . . . . 072 010 . . . WASHER, shldr .316 ID x .812 OD x .187thk . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 20 . . . . . . . . . . . . . 124 778 . . . KNOB, T 2.000 bar w/.312-18 x 1.000lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 21 . . . . . . . . . . . . . 079 625 . . . WASHER, wave .500 ID x .750 OD x .015thk . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . 22 . . . . . . . . . . . . . 092 865 . . . KEY, stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 23 . . . . . . . . . . . . . 172 077 . . . CARRIER, drive roll keyed 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . 24 . . . . . . . . . . . . . 121 271 . . . SCREW, .250-20 x .500 soc hd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
12
11
10
13
9
14
8
7
6
5
15
4
3
16
2
1
21
24
23
20
22
19
18
17
802 018-A
Figure 7-3. Drive Assembly, Wire (4 Drive Roll )
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-186 895 Page 26
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 7-1. Drive Roll And Wire Guide Kits (2 Drive Roll)
Base selection of drive rolls upon the following recommended usages:
1. V-Grooved rolls for hard wire.
2. U-Grooved rolls for soft and soft shelled cored wires.
3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).
4. V-Knurled rolls for hard shelled cored wires.
NOTE
5. Drive roll types may be mixed to suit particular requirements (example:
V-Knurled roll in combination with U-Grooved).
Wire Diameter
Drive Roll
Part No.
Inlet
Kit No.
Wire Guide
Fraction
.023/.025 in
.030 in
Decimal
.023/.025 in
.030 in
Metric
0.6 mm
0.8 mm
0.9 mm
Type
087 131
079 594
079 595
087 130
053 695
053 700
V-Grooved
V-Grooved
V-Grooved
056 192
056 192
056 192
.035 in
.035 in
.040 in
.045 in
.052 in
1/16 in
.040 in
.045 in
.052 in
.062 in
1.0 mm
1.2 mm
1.3 mm
1.6 mm
161 189
079 596
079 597
079 598
053 696
053 697
053 698
053 699
V-Grooved
V-Grooved
V-Grooved
V-Grooved
056 192
056 193
056 193
056 195
.035 in
.045 in
.052 in
.035 in
.045 in
.052 in
0.9 mm
1.2 mm
1.3 mm
044 749
079 599
079 600
072 000
053 701
053 702
U-Grooved
U-Grooved
U-Grooved
056 192
056 193
056 193
1/16 in
5/64 in
.062 in
.079 in
1.6 mm
2.0 mm
079 601
079 602
053 706
053 704
U-Grooved
U-Grooved
056 195
056 195
.035 in
.035 in
0.9 mm
079 606
132 958
V-Knurled
056 192
.045 in
.052 in
1/16 in
.045 in
.052 in
.062 in
1.2 mm
1.3 mm
1.6 mm
079 607
079 608
079 609
132 957
132 956
132 955
V-Knurled
V-Knurled
V-Knurled
056 193
056 193
056 195
.068-.072 in
5/64 in
.068-.072 in
.079 in
1.8 mm
2.0 mm
089 984
079 610
132 959
132 960
V-Knurled
V-Knurled
056 195
056 195
.045 in
.052 in
1/16 in
5/64 in
.045 in
.052 in
.062 in
.079 in
1.2 mm
1.3 mm
1.6 mm
2.0 mm
083 318
083 317
079 614
079 615
083 489
083 490
053 708
053 710
U-Cogged
U-Cogged
U-Cogged
U-Cogged
056 193
056 193
056 195
056 195
S-0157-C
OM-186 895 Page 27
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 7-2. Drive Roll & Wire Guide Kits (4 Drive Roll)
Base selection of drive rolls upon the following recommended usages:
1. V-Grooved rolls for hard wire.
2. U-Grooved rolls for soft and soft shelled cored wires.
3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).
4. V-Knurled rolls for hard shelled cored wires.
NOTE
5. Drive roll types may be mixed to suit particular requirements (example:
V-Knurled roll in combination with U-Grooved).
Wire Diameter
Decimal
.023/.025 in .023/.025 in
Drive Roll
Wire Guide
Kit No.
Fraction
Metric
0.6 mm
0.8 mm
0.9 mm
Part No.
Type
Inlet
Intermediate
087 132
046 780
046 781
087 130
053 695
053 700
V-Grooved
V-Grooved
V-Grooved
056 192
056 192
056 192
056 206
.030 in
.035 in
.030 in
.035 in
056 206
056 206
.040 in
.045 in
.052 in
1/16 in
.040 in
.045 in
.052 in
.062 in
1.0 mm
1.2 mm
1.3 mm
1.6 mm
191 917
046 782
046 783
046 784
053 696
053 697
053 698
053 699
V-Grooved
V-Grooved
V-Grooved
V-Grooved
056 192
056 193
056 193
056 195
056 206
056 207
056 207
056 209
.035 in
.045 in
.052 in
.035 in
.045 in
.052 in
0.9 mm
1.2 mm
1.3 mm
044 750
046 785
046 786
072 000
053 701
053 702
U-Grooved
U-Grooved
U-Grooved
056 192
056 193
056 193
056 206
056 207
056 207
1/16 in
5/64 in
.062 in
.079 in
1.6 mm
2.0 mm
046 787
046 788
053 706
053 704
U-Grooved
U-Grooved
056 195
056 195
056 209
056 209
.035 in
.045 in
.052 in
1/16 in
.035 in
.045 in
.052 in
.062 in
0.9 mm
1.2 mm
1.3 mm
1.6 mm
046 792
046 793
046 794
046 795
132 958
132 957
132 956
132 955
V-Knurled
V-Knurled
V-Knurled
V-Knurled
056 192
056 193
056 193
056 195
056 206
056 207
056 207
056 209
.068-.072 in .068-.072 in 1.8 mm
089 985
046 796
132 959
132 960
V-Knurled
V-Knurled
056 195
056 195
056 209
056 209
5/64 in
.079 in
2.0 mm
.045 in
.052 in
1/16 in
5/64 in
.045 in
.052 in
.062 in
.079 in
1.2 mm
1.3 mm
1.6 mm
2.0 mm
083 319
083 320
046 800
046 801
083 489
083 490
053 708
053 710
U-Cogged
U-Cogged
U-Cogged
U-Cogged
056 193
056 193
056 195
056 195
056 207
056 207
056 209
056 209
Ref. S-0025-D
OM-186 895 Page 28
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
OM-186 895 Page 29
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
OM-186 895 Page 30
Download from Www.Somanuals.com. All Manuals Search And Download.
Effective January 1, 1999
(Equipment with a serial number preface of “KK” or newer)
Warranty Questions?
Call
1-800-4-A-MILLER
for your local
Miller distributor.
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY − Subject to the terms and conditions
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants
to its original retail purchaser that new Miller equipment sold
after the effective date of this limited warranty is free of defects
in material and workmanship at the time it is shipped by Miller.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS.
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting
Torches
*
*
*
*
Remote Controls
Accessory Kits
Replacement Parts (No labor)
Spoolmate 185
Your distributor also gives
you ...
Within the warranty periods listed below, Miller will repair or
replace any warranted parts or components that fail due to
such defects in material or workmanship. Miller must be
notified in writing within thirty (30) days of such defect or
failure, at which time Miller will provide instructions on the
warranty claim procedures to be followed.
Miller’s True Blue® Limited Warranty shall not apply to:
Service
1. Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
2. Consumable components; such as contact tips, cutting
nozzles, contactors, brushes, slip rings, relays or parts
that fail due to normal wear.
Miller shall honor warranty claims on warranted equipment
listed below in the event of such a failure within the warranty
time periods. All warranty time periods start on the date that
the equipment was delivered to the original retail purchaser, or
one year after the equipment is sent to a North American
distributor or eighteen months after the equipment is sent to an
International distributor.
Support
3. Equipment that has been modified by any party other
than Miller, or equipment that has been improperly
installed, improperly operated or misused based upon
industry standards, or equipment which has not had
reasonable and necessary maintenance, or equipment
which has been used for operation outside of the
specifications for the equipment.
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
1. 5 Years Parts − 3 Years Labor
*
*
Original main power rectifiers
Inverters (input and output rectifiers only)
MILLER PRODUCTS ARE INTENDED FOR PURCHASE
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND
PERSONS TRAINED AND EXPERIENCED IN THE USE
AND MAINTENANCE OF WELDING EQUIPMENT.
2. 3 Years — Parts and Labor
*
*
*
*
*
*
Transformer/Rectifier Power Sources
Plasma Arc Cutting Power Sources
Semi-Automatic and Automatic Wire Feeders
Inverter Power Supplies
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the goods
at customer’s risk and expense. Miller’s option of repair or
replacement will be F.O.B., Factory at Appleton, Wisconsin, or
F.O.B. at a Miller authorized service facility as determined by
Miller. Therefore no compensation or reimbursement for
transportation costs of any kind will be allowed.
Intellitig
Engine Driven Welding Generators
(NOTE: Engines are warranted separately by the
engine manufacturer.)
3. 1 Year — Parts and Labor
*
Motor Driven Guns (w/exception of Spoolmate
185)
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR
ANY OTHER LEGAL THEORY.
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Process Controllers
Positioners and Controllers
Automatic Motion Devices
Robots
IHPS Power Sources
Water Coolant Systems
HF Units
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN
AND ANY IMPLIED WARRANTY, GUARANTY OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
Grids
Spot Welders
PROVISION,
MIGHT
ARISE
BY
IMPLICATION,
Load Banks
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND
DISCLAIMED BY MILLER.
SDX Transformers
Miller Cyclomatic Equipment
Running Gear/Trailers
Plasma Cutting Torches (except APT, ZIPCUT &
PLAZCUT Models)
Some states in the U.S.A. do not allow limitations of how long
an implied warranty lasts, or the exclusion of incidental,
indirect, special or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty
provides specific legal rights, and other rights may be
available, but may vary from state to state.
*
*
Deutz Engines (outside North America)
Field Options
(NOTE: Field options are covered under True
Blue® for the remaining warranty period of the
product they are installed in, or for a minimum of
one year — whichever is greater.)
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein,
and to the extent that they may not be waived, the limitations
and exclusions set out above may not apply. This Limited
Warranty provides specific legal rights, and other rights may
be available, but may vary from province to province.
4. 6 Months — Batteries
5. 90 Days — Parts
*
MIG Guns/TIG Torches
miller_warr 1/99
Download from Www.Somanuals.com. All Manuals Search And Download.
Owner’s Record
Please complete and retain with your personal records.
Model Name
Purchase Date
Distributor
Address
Serial/Style Number
(Date which equipment was delivered to original customer.)
City
State
Zip
Resources Available
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
To locate distributor nearest you call
1-800-4-A-Miller.
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
European Headquarters −
United Kingdom
Phone: 44 (0) 1204-593493
FAX: 44 (0) 1204-598066
Welding Process Handbooks
Contact the Delivering Carrier for:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims,
contact your distributor and/or equipment
manufacturer’s Transportation Department.
PRINTED IN USA
© 1999 Miller Electric Mfg. Co. 9/98