Operating and Installation
Instructions
Ventilation System
DA 211
DA 218
To prevent accidents
and machine damage,
read these instructions
before
UV
installation or use.
M.-Nr. 05 802 950
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Turning on the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Turning off the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Turning the lighting on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Filter timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Reprogramming the timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Cleaning the casing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Retaining plates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Inserting the non-return flap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
3
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
Read these Operating Instructions carefully before installing or
using the Ventilation System.
This appliance is designed to vent
cooking smoke and odors only.
This appliance is intended for
residential use only. Use the
appliance only for its intended
purpose. The manufacturer cannot
be held responsible for damages
caused by improper use of the
hood.
Be certain your appliance is
properly installed and grounded by
a qualified technician.
To guarantee the electrical safety of this
appliance, continuity must exist
between the appliance and an effective
grounding system. It is imperative that
this basic safety requirement be met. If
there is any doubt, have the electrical
system of the house checked by a
qualified electrician. The manufacturer
cannot be held responsible for
damages caused by the lack, or
inadequacy, of an effective grounding
system.
This appliance complies with current
safety requirements. Improper use of
the appliance can lead to personal
injury and material damage.
READ AND SAVE THESE
INSTRUCTIONS
Before connecting the appliance to
the power supply make sure that
the voltage and frequency listed on the
data plate correspond with the
household electrical supply. This data
must correspond to prevent machine
damage. If in doubt consult a qualified
electrician.
,CAUTION
Use only for general ventilation.
Do not use to exhaust hazardous or
explosive materials and vapors.
Installation work and repairs should
only be performed by a qualified
technician in accordance with all
applicable codes and standards.
Repairs and other work by unqualified
persons could be dangerous and the
manufacturer will not be held
responsible.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
This equipment is not designed for Use
maritime use or for use in mobile
installations such as recreational
vehicles or aircraft. However, under
certain conditions it may be possible for
installation in these applications. Please
contact the nearest Miele dealer or the
Technical Service Department with
specific requirements.
Do not allow children to play with
or operate the appliance or its
controls. Supervise its use by the
elderly or infirm.
Be careful when preparing a
flambé beneath the hood.
Flames may be drawn up into the hood
by the suction and the grease filters
may catch fire.
Before servicing or cleaning the
unit, switch power off at the service
panel and lock the service
disconnecting means to prevent power
from being switched on accidentally. If
the service disconnecting means
cannot be locked, securely fasten a
prominent warning device, such as a
tag, to the service panel.
Do not use the hood without the
grease filters in place.
Clean the grease filters regularly.
Dirty filters are a fire hazard.
Do not use a steam cleaner to
clean the hood. Steam could
penetrate the electrical components
and cause a short circuit.
Before discarding an old
appliance, unplug it from the
Always turn on the hood when
using the cooktop to prevent
damage from condensation.
power supply and remove the power
cord and any doors to prevent hazards.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
, WARNING - TO REDUCE
THE RISK OF A COOKTOP
GREASE FIRE:
, WARNING
TO REDUCE THE RISK OF INJURY
TO PERSONS IN THE EVENT OF A
COOKTOP GREASE FIRE, OBSERVE
THE FOLLOWING:
Never leave surface units
unattended at high settings.
Boilovers cause smoking and greasy
spillovers may ignite. Heat oils slowly
on low or medium settings.
SMOTHER FLAMES with a close
fitting lid, cookie sheet, or metal
tray, then turn off the burner.
BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE
DEPARTMENT.
Always turn the hood on when
cooking at high heat or when
cooking flaming foods.
Clean ventilation fans frequently.
Grease should not be allowed to
accumulate on the fan or filter.
NEVER PICK UP A FLAMING
PAN - You may be burned.
DO NOT USE WATER, including
wet dishcloths or towels - a violent
steam explosion may result.
Use the proper pan size. Always
use cookware appropriate for the
size of the surface element.
Use a fire extinguisher
ONLY if:
– You have a Class ABC extinguisher,
and know how to operate it.
– The fire is small and contained in the
area where it started.
– The fire department has been called.
– You can fight the fire with your back
to an exit.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
Installation
Any fittings, sealant, or materials
used to install the ductwork must
be made of approved non-flammable
, WARNING
To reduce the risk of fire only
use metal ductwork.
materials.
Never connect an exhaust hood to
When installing the hood, follow the
recommended minimum safety
distances between a Miele cooktop and
the hood:
an active chimney, dryer vent, vent
flue, or room ventilating ductwork. Seek
professional advice before connecting
an exhaust hood vent to an existing,
– 22" (55 cm) above electric cooktops, inactive chimney or vent flue.
– 26" (65 cm) above gas cooktops,
– 26" (65 cm) above an open grill.
Ducted fans must always be
vented outdoors.
Make sure that the airflow in the
room is sufficient for combustion
and exhausting of all non-electric
heating appliances (water heaters, gas
cooktops, gas ovens, etc.), otherwise
backdrafts may occur. Follow the
heating manufacturer’s guidelines and
safety standards or those published by
the National Fire Protection Association
(NFPA), or the American Society for
Heating, Refrigeration and Air
If local building codes require a greater
safety distance, follow their
requirement.
For non-Miele cooking appliances
maintain the safety distances
recommended by the appliance
manufacturer.
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
Conditioning Engineers (ASHRAE).
If in doubt, consult an experienced
professional.
Be careful not to damage hidden
electrical wiring or plumbing when
cutting or drilling into the wall or ceiling.
Do not use an extension cord to
connect the appliance to electricity.
Extension cords do not guarantee the
required safety of the appliance, (e.g.
danger of overheating).
Do not install this hood over
cooktops burning solid fuel.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Guide to the appliance
a Chimney extension
b Chimney
m Grease filter button
The indicator above the grease filter
button lights when the grease filters
need to be cleaned. This button is also
used:
c Canopy
– to reset the grease filter timer after
cleaning the grease filters (see
"Cleaning and Care").
d Control panel
e Active charcoal filter
f Recirculation vent
g Overhead lighting
h Grease filters
i Light button
– to show how long the grease filters
have been in use (see "Operation /
Filter timers").
– to change the number of hours
counted by the grease filter timer
(see "Operation / Reprogramming the
filter timers").
n Charcoal filter button
(used in recirculation mode only)
j On/Off button
The indicator above the charcoal filter
button lights when the charcoal filters
need to be replaced.
k Fan power level buttons
Four fan speed selection
This button is also used:
l Delayed Shut Down
– to reset the charcoal filter timer after
changing the filters (see "Cleaning
and care").
This button activates the Delayed Shut
Down feature. The fan can be set to
turn off automatically after either 5 or 15
minutes.
– to show how long the charcoal filters
have been in use (see "Operation /
Filter timers")
– to change the number of hours
counted by the charcoal filter timer
(see "Operation / Reprogramming the
timers").
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Functional description
The hood offers two modes of
operation:
Air extraction
Recirculation mode
The air is drawn in and cleaned by the
grease filters and directed outside.
Air is drawn through the grease filters
and an active charcoal filter. The
filtered air is then recirculated back into
the kitchen through a vent at the top of
the hood’s chimney.
The hood comes equipped with a
non-return flap. This flap automatically
closes when the hood is turned off so
that no exchange of outside air and
room air can occur. When the hood is
turned on, the air pressure of the
exhaust fan automatically opens the
flap blowing the inside air and cooking
odors outside.
Before using the hood in
recirculation mode, ensure that the
active charcoal filters are in place,
see "Cleaning and care".
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Turning on the fan
Selecting the power level
^ Use the _ controls to select the
^ Press the On/Off button.
desired power level.
The fan runs at power level "2".
The On/Off indicator lights.
& =increases the fan speed
$ =decreases the fan speed
Level "1" to "3" (green indicators) are
usually sufficient for normal cooking.
Intensive setting
Level "4" (yellow indicator) should be
used for a short period when frying or
cooking food with a strong aroma.
Fan performance
The maximum air flow capacity is
625 cfm. Factors such as narrow duct
diameter and bends will affect this
value.
Level 1 operates at 40% capacity
Level 2 operates at 60% capacity
Level 3 operates at 80% capacity
Level 4 operates at 100% capacity
There will also be a slight decrease in
airflow for hoods operated in
recirculation mode due to the active
charcoal filter.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Delayed Shut Down
Turning the lighting on/off
If odors or smoke remain in the kitchen
after cooking has been completed, the
Delayed Shut Down feature can be
selected to allow the hood to continue
running for either 5 or 15 minutes.
The overhead lighting can be turned
on and off independently of the fan.
^ Press the light button briefly to turn
on the lighting.
^ Press the Delayed Shut Down button
while the fan is still running.
The light button indicator illuminates.
^ Press the light button briefly again to
Press once = 5 minute delay
(left indicator lights)
Press twice = 15 minute delay
(right indicator lights)
turn off the lighting.
The light button indicator will go out.
Dimming the lighting
To cancel the Delayed Shut Down
feature press the button again.
The brightness of the lighting can be
adjusted.
Turning off the fan
^ While the lighting is turned on, press
the light button.
The lighting will dim until the button is
released.
^ If the button is pressed again, the
lighting will brighten until the button is
released.
^ Press the On/Off button to turn the
fan off.
The indicator goes out.
If the button is pressed continuously,
the light will cycle between bright and
dark.
Automatic Safety Shut Off
The fan will turn off automatically 10
hours after the last button was activated.
The lighting however will remain on.
^ Press the light button again to turn off
the lighting.
^ Press the On/Off button to turn the
fan back on again.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Filter timers
Checking the filter timers
To check the percentage of time
already used:
Grease filters
A timer monitors the hours of fan
operation. The indicator for the grease
filter will light after 30 hours of
operation. The grease filters must then
be cleaned.
^ Press the On/Off button to turn the
fan on.
After the grease filters have been
cleaned and put in place, the grease
filter timer must be reset.
^ Press the grease or charcoal filter
button.
^ To do this, press the grease filter
button for about 3 seconds.
The indicator will go out.
Charcoal filters
The number of flashing _ indicators
show the percentage of programmed
hours that have been used.
The timer for the charcoal filter is not
preset. Please program this timer, see
"Operation/Reprogramming the
charcoal filter timer".
1 indicator = less than 25 %
2 indicators = less than 50 %
3 indicators = less than 75 %
4 indicators = less than 100 %
The charcoal filter indicator will light
once the selected time has elapsed.
The charcoal filters must then be
replaced and the charcoal filter timer
must be reset.
This information will remain stored in
memory in the event of a power failure.
^ To do this, press the charcoal filter
button for about 3 seconds.
The indicator will go out.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Reprogramming the timers
The grease filter timer is preset to 30
hours. This time can be lengthened or
shortened to 20, 30, 40 or 50 hours.
The indicator for the grease filter and
one of the _ indicators will flash.
– A time of 20 hours should be
programmed in kitchens with
frequent pan or deep frying.
The lit indicator shows the programmed
time:
– A time of 20 hours should also be
programmed if the kitchen is only
used occasionally. Otherwise grease
which has accumulated over a long
period of time will harden on the
filters making cleaning more difficult.
1st indicator from the left = 20 hours
2nd indicator from the left = 30 hours
3rd indicator from the left = 40 hours
4th indicator from the left = 50 hours
^ Use the $ or & button to select the
desired time.
Reprogramming the grease filter
timer
^ Store the selection by pressing the
grease filter button.
^ Press the On/Off button to turn off the
fan.
If the procedure is not stored within
4 minutes of programming, the hood
will automatically default to the "old"
data.
^ Press the Delayed Shut Down and
grease filter buttons at the same time.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Reprogramming the charcoal filter
timer
The active charcoal filter can only be
used in recirculation mode and can not
be used to exhaust fumes.
The indicator for the charcoal filter and
one of the _ indicators will flash.
The charcoal filter timer is not preset.
The lit indicator shows the programmed
time:
Before using the hood in recirculation
mode, the charcoal filter timer must be
programmed.
1st indicator from the left = 20 hours
2nd indicator from the left = 30 hours
3rd indicator from the left = 40 hours
4th indicator from the left = 50 hours
^ Use the $ or & button to select the
desired time.
^ Turn off the fan using the On/Off
button.
^ Store the selection by pressing the
charcoal filter button.
^ Press the Delayed Shut Down and
Charcoal Filter buttons at the same
time.
If the procedure is not stored within
4 minutes of programming, the hood
will automatically default to the "old"
data.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Stainless steel
Before cleaning or servicing the
hood, disconnect it from the power
supply by either removing the fuse,
unplugging it from the outlet or
manually "tripping" the circuit
breaker.
Stainless steel surfaces can be cleaned
using a non-abrasive stainless steel
cleaner.
To help prevent resoiling, a conditioner
for stainless steel can also be used.
Apply sparingly with even pressure.
Cleaning the casing
Stainless steel colored controls
,Never use abrasive cleaners,
scouring pads, steel wool or caustic
(oven) cleaners on the hood. They
will damage the surface.
These controls may become
discolored or damaged if not
cleaned regularly.
Do not use a stainless steel cleaner
on these controls.
^ All external surfaces and controls can
be cleaned with warm water and
liquid dish soap applied with a soft
sponge.
^ Wipe dry using a soft cloth.
Do not use too much water when
cleaning the controls. Water could
penetrate into the electronics and
cause damage.
Avoid:
– cleaning agents containing soda,
acids or chlorides,
– abrasive cleaning agents e.g.
powder or cream cleansers,
– abrasive sponges, e.g. pot scourers
or sponges which have been
previously used with abrasive
cleaning agents.
These will damage the surface.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Grease filters
Depending on the detergent,
The reusable metal grease filters
remove solid particles from the vented
kitchen air (grease, dust, etc).
cleaning the grease filters in a
dishwasher may cause permanent
discoloration of the filter surface.
Performance of the filter will not be
affected by this discoloration.
^ After cleaning, the filters can be
placed on a towel to air dry.
The grease filters should be cleaned
every 3 - 4 weeks or whenever the
grease filter indicator lights.
^ While the filters are removed, clean
any dirt or grease from the filter
casing to prevent the risk of fire.
A dirty filter is a fire hazard.
When putting the grease filters back
make sure that the locking clips are
visible facing down towards the
cooking surface.
If a filter is incorrectly installed, insert a
small screwdriver into the slit along its
edge to disengage it from the casing.
^ After returning the grease filters,
press the grease filter button for
3 seconds to reset the timer.
The indicator light will go out.
^ To remove the grease filters press the
locking clips in towards the middle of
the filter. Holding carefully, lower and
remove the filter.
^ If the grease filters are cleaned
before the timer has reached its
maximum, the grease filter button
should be pressed for 6 seconds to
reset the counter to zero.
^ Clean the filters
- by hand: use a scrub brush in
warm water with a mild detergent.
- in a dishwasher: place the filters in
the lower basket, making sure that
the spray arm is not blocked.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Active charcoal filters
In recirculation mode two active
charcoal filters must be used in
addition to the grease filters. The
charcoal filters are designed to absorb
cooking odors.
^ After replacing the charcoal filters,
press and hold the charcoal filter
button for about 3 seconds to reset
the charcoal filter timer.
Replacement active charcoal filters
can be ordered from the
The indicator light will go out.
^ If the charcoal filters are replaced
before the timer has reached its
maximum, the charcoal filter button
should be pressed for 6 seconds to
reset the counter to zero.
Miele Technical Service Department.
USA 1-800-999-1360
CDN 1-800-565-6435
Please quote part # 03 284 681.
^ Remove the grease filters to access
the charcoal filters.
Follow the instructions supplied with the
active charcoal filters.
Replace the active charcoal filters when
the charcoal filter indicator lights.
Replace the filters at least every 6
months or when they no longer absorb
odors efficiently.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning and Care
Changing the light bulb
Before changing the light bulbs,
disconnect the hood from the power
supply by either removing the fuse,
unplugging it, or manually "tripping"
the circuit breaker.
When in use halogen bulbs become
extremely hot, and they can burn
your hands. Do not attempt to
change the bulbs until they have
had sufficient time to cool.
^ To change the halogen bulb first
remove the lamp cover, a.
^ Pull the bulb, b, out of its socket and
replace with a new one.
Do not touch the bulb surface.
Fingerprints or body oils deposited
on the bulb will decrease the life of
the bulb.
Follow the bulb manufacturer’s
instructions.
^ Return the lamp cover, a.
Never use the lighting without the
lamp cover, a, in place. The glass is
specially made to filter harmful light
rays.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
After Sales Service
In the event of a fault which you cannot
correct yourself please contact the
Miele Technical Service Department :
U
1-800-999-1360
V
1-800-565-6435
When contacting the Technical Service
Department, please quote the model
and serial number of your appliance.
These are shown on the data plate
which is visible when the grease filter is
removed.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Caring for the environment
Disposal of packing material
Disposal of an old appliance
The cardboard box and packing
materials protect the appliance during
shipping. They have been designed to
be biodegradable and recyclable.
Please recycle.
Old appliances may contain materials
that can be recycled. Please contact
your local recycling authority about the
possibility of recycling these materials.
Before discarding an old hood,
unplug it from the outlet and cut off
its power cord to prevent hazards.
To prevent suffocation of children,
ensure that any plastic wrappings,
bags, etc. are disposed of safely
and kept out of their reach.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation accessories
a
2 recirculation vents
(recirculation mode only)
b
2 protective shields
prevent scratches to the chimney
during installation.
12 large headed screws 5 x 40 mm
for securing the retaining plates and the
canopy.
c
1 protective shield
prevents scratches from the canopy
during installation.
(S8 wall anchors included in the
packaging are not for use in USA /
CDN.)
d
1 diverter
(recirculation mode only)
e
1 flex hose for connecting the
diverter to the exhaust connection.
2 M 6 locking nuts for securing the
motor assembly.
f
2 hose clips for securing the
ducting.
g
1 reducing collar
for use with 5" (125 mm) exhaust
ducting.
h
1 non-return flap for vented air
4 screws 3.9 x 7.5 mm for securing the
extraction only.
chimney and the chimney extension
i
Upper retaining plate B secures
the chimney extension.
j
Middle retaining plate C for
CAUTION:
additional stability of the chimney.
During the installation process
please be careful of sharp edges
that can cause harm.
k
Lower retaining plate A secures
the canopy and motor assembly.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Plywood backing
^ Hold retaining plate A against the
wall so that the marks are visible
through the holes of the plate (see
"Installation / Retaining plate A").
Draw a line around the plate’s
The majority of the weight of the
installed ventilation system will be
supported by retaining plate A. It
must be firmly attached to the stud
framing behind the drywall. If studs
are not available in the required
locations, a plywood backing (min.
1/2" (13 mm) thick) spanning at least
two studs must be installed. Failure
to adequately support the weight as
stated may result in the ventilation
system falling off the wall, causing
personal injury and property
perimeter, then set aside the plate.
^ Make a cutting line 3" (76 mm) above
and 3" (76 mm) below the outline of
plate "A".
^ Find the studs to the left and right of
the mounting location by tapping the
wall or using a stud finder.
^ Mark a vertical cutting line along the
center of each stud.
damage.
Be careful not to damage any wiring
or plumbing that may be located
behind the wall. Make sure that the
power supply to the area where this
installation is being performed has
been turned off at the breaker panel
before cutting into the wall.
(If plywood backing is not needed,
proceed to "Attaching the retaining
plates to the wall." )
To install a plywood backing board
^ Remove the drywall between the
cutting lines and replace it with
plywood of a matching thickness
(min. 1/2" (13 mm) thick). Tape the
joints and refinish the wall.
^ Proceed to "Attaching the Retaining
plates to the wall" to complete the
installation.
^ Make a mark, S + 16 3/4" (425 mm)
above the cooktop and on the
centerline.
^ Make a second mark 12 3/4 "
(324 mm) underneath the first one.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical data
Important
All electrical work should be
performed by a qualified electrician
in strict accordance with national
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer can
not be held responsible for
The hood comes equipped with a 5 ft
(1.5 m) power cord with a NEMA 5-15
molded plug for connection to a
120 VAC, 60 Hz, 15 A power outlet.
Maximum load
DA 217-2, 219-2 . . . . . . . . . . . . . 410 W
unauthorized work.
Ensure that power to the appliance
is OFF while installation or repair
work is performed.
Lighting
DA 217-2, 219-2 . . . . . . . . . . . 3 x 20 W
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
Frequency . . . . . . . . . . . . . . . . . . 60 Hz
Circuit rating. . . . . . . . . . . . . . . . . . 15 A
Verify that the voltage, load and circuit
rating information found on the data
plate (located behind the grease
filters), match the household electrical
supply before installing the hood.
If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or call Miele’s
Technical Service Department.
USA 1-800-999-1360
CDN 1-800-565-6435
WARNING:
THIS APPLIANCE MUST BE
GROUNDED
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions
Standard unit height H:
Do not install this exhaust hood over
cooktops burning solid fuel.
DA 211
Extraction . . . . . . . . . . . . 29 1/8" - 37 1/2"
. . . . . . . . . . . . . . . . . . . (740 - 978 mm)
Recirculation. . . . . . . . . . 32 3/4" - 41 7/8"
. . . . . . . . . . . . . . . . . . (832 - 1064 mm)
When installing the hood, make sure
that the following minimum
distance (S) between the top of a
Miele cooking surface and the
bottom of the hood is:
- 22" (55 cm) above electric cooktops
- 26" (65 cm) above gas cooktops
- 26" (65 cm) above an open grill
DA 218
Extraction . . . . . . . . . . . . 29 1/8" - 38 1/4"
. . . . . . . . . . . . . . . . . . . (740 - 972 mm)
Recirculation. . . . . . . . . . 31 3/4" - 40 7/8"
. . . . . . . . . . . . . . . . . . (807 - 1038 mm)
For non-Miele cooking appliances
maintain the safety distances
recommended by the cooktop
manufacturer in their installation and
operating instructions.
* With air extraction to the rear through
a wall the total height must be at least
31 1/8" (790 mm).
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
To fit the chimney, distance A between
the top of the chimney and the ceiling
must be at least 7/8" (20 mm).
Cut out area in wall or ceiling for
entrance of 6" (150 mm)
ductwork or 5" (125 mm)
See "Warning and Safety
instructions" for further information.
ductwork with a reducing collar.
26" (65 cm) is recommended for all
installations to allow for optimum work
space under the hood.
Read the entire installation procedures
and determine height (S) before
beginning the installation. Installation
producers differ depending on the
model and venting method.
If the hood is fitted flush to the ceiling
make sure that the remaining distance
to the ceiling is not greater or less than
appliance height H.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Appliance dimensions
If the standard unit height H is not suitable to the kitchen’s ceiling height, longer
optional chimney extensions are available from your Miele dealer or Miele’s
Technical Service Department.
DA 211
Extraction
Recirculatio8n
2
1
7
1
8
3
4
Standard unit H
29 / " - 38 / "
32 / " - 41 / "
740 mm - 978 mm
832 mm - 1064 mm
DATK 217/219 605
DATK 217/219 840
38 1/2" - 48"
978 mm - 1220 mm
41 7/8" - 51 3/16"
1064 mm - 1300 mm
51 3/16" - 60 1/2"
1
2
48" - 57 / "
1220 mm - 1460 mm
1300 mm - 1536 mm
DA 218
Extraction
Recirculatio8n
4
1
7
1
3
8
4
Standard unit H
29 / " - 38 / "
31 / " - 40 / "
740 mm - 971 mm
806 mm - 1038 mm
16
3
1
7
4
8
DATK 217/219 605
DATK 217/219 840
38 / " - 47"
40 / " - 50 / "
971 mm - 1195 mm
1038 mm - 12275 mm
1
1
2
3
16
47" - 56 / "
50 / " - 59 / "
1195 mm - 1435 mm
1275 mm - 1511 mm
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Retaining plates
Attaching the retaining plates
to the wall
^ Before fitting the retaining plate draw
a vertical line centrally above the
cooktop on the rear wall.
The ventilation system will be mounted
to the wall through the use of retaining
plates. Plate A is installed first,
followed by plate B. Plate C should only
be used if the distance between plate A
and plate B is greater than 14 3/8"
(365 mm).
^ Mark measurement S from the
cooktop surface upwards (see
"Appliance dimensions"). This marks
the height of the lower rim of the
hood.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Retaining plate A
^ Drill two 1/8" (3 mm) holes, one at S +
4" (100 mm) and one at S + 16 3/4"
(425 mm) on the center line for the
retaining plate (see "Appliance
dimensions").
^ Lightly secure retaining plate A into
position using 5 x 40 mm screws
through the two holes and use the
notches to align with the center line.
^ Drill 4 more 1/8" (3 mm) holes through
the now fitted retaining plate.
^ Screw two 5 x 40 mm screws into the
upper two holes.
Retaining plate B
^ Hold retaining plate B to the wall and
push up until it is directly below the
ceiling. Use the notches and the
center line to align it horizontally.
Mark the 2 drill holes on the wall.
^ Drill two 1/8" (3 mm) holes into the
wall.
^ Secure the retaining plate with two
5 x 40 mm screws.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Retaining plate C
Attaching the canopy
^ Hang the canopy on the angled
brackets on retaining plate A.
Retaining plate C should only be used if
dimension Y is greater than 14 3/
"
(365 mm.) It provides additional 8
stability for the chimney extension.
^ At a maximum distance of 14 3/8"
(365 mm) from the ceiling hold
retaining plate C against the wall and
use the notches to align it with the
center line. Mark the two drill holes.
^ Drill two 1/8" (3 mm) holes into the
wall.
^ Secure retaining plate C with two
5 x 40 mm screws.
^ Secure the canopy with 5 x 40 mm
screws into each drilled hole.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Inserting the non-return flap
Attaching the motor assembly
^ First loosely screw the two locking
nuts onto the threaded bolts on
retaining plate A.
^ Air extraction:
If a non-return flap is not present in
the venting system, the non-return
flap supplied must be fitted into the
exhaust connection on the motor. The
flaps must open upwards.
Leave a gap of 1/8" (3 mm) for
hanging the motor on.
^ The hood is designed for 6" (150 mm)
exhaust ducting. If 5" (125 mm)
exhaust ducting is used the reducing
collar must be fitted into the exhaust
connection on the motor (see "Air
extraction").
^ Recirculation mode:
The non-return flap is not required.
^ Fit the motor assembly onto the
hooks on retaining plate A and slide
down behind the nuts.
^ Tighten the nuts.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Electrical connection
Air extraction exhaust
connection
Before connecting the appliance
read the "Warning and Safety
Instructions" and the "Electrical data"
sections.
^ Connect the ductwork to the exhaust
connection using whatever means
are appropriate for the type of
ductwork being installed (hose
clamp, duct tape, etc.)
^ Direct the duct through the back wall
or the ceiling.
^ Plug the 2 connectors on the canopy
into the corresponding receptacles
left and right of the motor assembly.
^ See "Air extraction" for further details.
Insert the 4 prong connector into the
rear and the 3 prong connector into
the front receptacle left of the motor
assembly.
Insert the 6 prong connector into the
receptacle right of the motor
assembly.
^ Secure the cords with the ties, as
shown above.
^ Plug in the power cord.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Recirculation connection
Attaching the chimney
extension
Recirculation mode is used when
venting to the outside of the building is
not possible.
The use of a chimney extension, allows
the hood to be installed at various
distances from the ceiling.
NOTE: The extension must be
intalled in relationship to the method
of venting; Extraction or
Recirculation.
^ Slide the diverter on to the brackets
of plate B.
Recirculation
Air extraction
The extension piece has vented
openings on one end.
These vents are required for recir-
culation mode and will be closest to the
ceiling when installed.
^ Slip the hose clamps over the flex
hose onto the diverter and the motor
assembly exhaust connection. Once
in place, tighten the hose clamps.
For air extraction, the vents are not
required and are covered by the
chimney.
Active charcoal filters must be used
in the recirculation mode.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
^ Screw the extension piece firmly to
the upper retaining plate using two
3.9 x 7.5 mm screws.
^ Cover the screws with the supplied
cap covers.
^ Remove the protective foil from
chimney extension.
^ Bend the top hanging tabs 45°
inwards. This will make installing the
extension easier. Be careful of sharp
edges.
^ Only for recirculation:
With the slats pointing downwards,
install the recirculation vents through
the extension piece and into the
diverter.
Recirculation
Air extraction
^ Pull the chimney extension slightly
outwards and snap over the upper
retaining plate B.
When installing for recirculation, ensure
that the vents are positioned so they
line up with the diverter.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Attaching the chimney
^ Remove the protective foil from the
chimney.
^ Remove the backing from the
adhesive strips on the protective
shield.
^ Fold the protective shield at the top.
^ Remove the adhesive backing from
the shield.
^ Attach the protective shield to the
front of the chimney so that it
protrudes slightly below the bottom
edge.
^ Stick the shield to the chimney
extension so that it is smooth and
flush with the bottom.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
^ Secure the chimney to reatining plate
A on both sides with two
3.9 x 7.5 mm screws.
^ Remove the protective foil from the
canopy.
^ Pull the chimney apart slightly and
slide it over the chimney extension.
Do this carefully to prevent scatching
the two pieces.
^ Before using the appliance remove
the grease filter and remove the
protective foil from the filter frame.
Return the filter.
^ Slide the chimney down aligning its
lower screw holes with those on the
side of retaining plate A.
^ Remove the protective shields.
If the chimney is not tall enough an
optional chimney extension can be
ordered. See "Installation /
Appliance dimensions".
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Air extraction
Exhaust ducting and connections
,WARNING
– The ducting should be as short and
straight as possible, and the number
of sharp bends should be minimized.
Danger of toxic fumes.
Gas cooking appliances release
carbon monoxide that can be
harmful or fatal if inhaled.
The exhaust gases extracted by
the hood should be vented
outside of the building only.
– For most efficient air extraction, the
diameter of the ductwork should not
be less than 6" (150 mm). Use of flat
ducts also reduces the air extraction
efficiency.
– Noise levels of the hood will increase
if flat ducts or round ducts of less
than 6" (150 mm) in diameter are
used.
Do not terminate the exhaust
ducts in attics, garages,
crawlspaces, etc.
– Use smooth or flexible pipes made
from approved non-flammable
materials for exhaust ducting.
To reduce the risk of fire, only use
metal ductwork.
– Where the ductwork is horizontal, it
must slope away from the hood at
least 1/8" per foot (1 cm per meter) to
prevent condensation dripping into
the appliance.
Please read and follow the
"IMPORTANT SAFETY
INSTRUCTIONS" to reduce the risk of
personal injury. Follow all local building
codes when installing the hood.
– If the exhaust is ducted through an
outside wall, a Miele Telescopic Wall
Vent can be used.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Air extraction
Condensate trap
optional accessory
In some cases, a condensate trap may
also be required to collect and
evaporate any condensate which may
occur. This optional accessory is
available for ducts 4" (125 mm) and
5 7/8" (150 mm) in diameter.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet. The arrow on the casing
shows the venting direction.
If the exhaust is ducted into an inactive
flue, the air must be expelled parallel to
the flow direction of the flue.
Never connect an exhaust hood to
an active chimney, dryer vent, vent
flue, or room venting ductwork.
Seek professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.
Important!
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Alteration rights reserved / 1004
M.-Nr. 05 802 950 / 02
Download from Www.Somanuals.com. All Manuals Search And Download.
|