To avoid the risk of accidents  
or damage to this appliance,  
it is essential to read these  
instructions before it is installed  
and used for the first time.  
M.-Nr. 09 190 950  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Caring for the environment  
Disposal of the packing material Disposal of your old appliance  
The transport and protective packing  
Electrical and electronic appliances  
has been selected from materials which often contain materials which, if  
are environmentally friendly for  
handled or disposed of incorrectly,  
could be potentially hazardous to  
human health and to the environment.  
They are, however, essential for the  
correct functioning of your appliance.  
Please do not therefore dispose of it  
with your household waste.  
disposal, and should be recycled.  
Packaging e.g. cling film, polystyrene  
and plastic wrappings must be kept out  
of the reach of babies and young  
children. Danger of suffocation!  
Please dispose of it at your local  
community waste collection / recycling  
centre or contact your dealer for  
advice. Ensure that it presents no  
danger to children while being stored  
for disposal.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warning and Safety instructions  
Any other usage is not supported by  
This appliance complies with all  
relevant local and national safety  
requirements. Inappropriate use  
can, however, lead to personal injury  
and damage to property.  
the manufacturer and could be  
dangerous. Miele cannot be held liable  
for damage resulting from incorrect or  
improper use or operation of the  
appliance.  
This appliance is not intended for  
~
To avoid the risk of accidents and  
damage to the appliance, please  
read these instructions carefully  
before using it for the first time.  
They contain important information  
on the safety, installation, use and  
maintenance of the appliance.  
use by people with reduced physical,  
sensory or mental capabilities, or lack  
of experience or knowledge, unless  
they are supervised whilst using it or  
have been shown how to use it  
correctly by a person responsible for  
their safety.  
Keep these instructions in a safe  
place and ensure that all users are  
familiar with the contents. Pass them  
on to any future owner of the  
appliance.  
Safety with children  
This appliance is only intended for  
~
use by adults who have read these  
instructions.  
This appliance is not a toy! To  
~
Correct application  
prevent the risk of injury do not let  
children play with the appliance or its  
controls.  
This appliance is not designed for  
~
commercial use. It is intended for use in  
domestic households and in similar  
working and residential environments  
such as:  
Children under 8 years of age must  
~
be kept away from the cooker hood  
unless they are constantly supervised.  
– Shops  
Children 8 years and older may use  
~
the cooker hood only if they have been  
shown how to use it in a safe way and  
understand the hazards involved.  
– Offices and showrooms  
and by residents in establishments  
such as  
Please be aware that on cooker  
~
– Hostels and guesthouses  
hoods with halogen lighting, the lamps  
will get very hot during use and remain  
hot for some time after switching off. To  
safeguard against burning, keep  
children well away from the lamps at all  
times.  
It must only be used as a domestic  
~
appliance to extract vapours and  
remove odours from cooking.  
The cooker hood is not intended for  
~
outdoor use.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warning and Safety instructions  
Technical safety  
Installation, maintenance and  
~
repairs may only be carried out by a  
Before installation, check the cooker  
~
Miele authorised person in accordance  
with current national and local safety  
regulations.  
hood for visible signs of damage.  
Under no circumstances should you  
use a damaged appliance. It could be  
dangerous.  
Repairs and other work by unqualified  
persons could be dangerous. The  
manufacturer cannot be held liable for  
unauthorised work.  
Before connecting the appliance to  
~
the mains supply, make sure that the  
voltage and frequency details given on  
the data plate correspond with the  
on-site electricity supply, otherwise the  
appliance could be damaged. Consult  
a qualified electrician if in any doubt.  
Faulty components must only be  
~
replaced by genuine Miele original  
parts. The manufacturer can only  
guarantee the safety of the appliance  
when Miele replacement parts are  
used.  
The electrical safety of this  
~
appliance can only be guaranteed if it  
is correctly earthed. It is most important  
that this basic safety requirement is  
present and tested regularly, and  
where there is any doubt, the  
During installation, maintenance and  
~
repair work, the appliance must be  
disconnected from the mains electricity  
supply.  
household wiring system should be  
inspected by a qualified electrician.  
The manufacturer cannot be held liable  
for the consequences of an inadequate  
earthing system (e.g. electric shock).  
For safety reasons, this appliance  
~
may only be used when it has been  
fully installed.  
Only open the housing as described  
~
in the instructions given in the  
installation sheet and in the Cleaning  
and care section of this booklet. Under  
no circumstances should any other  
parts of the housing be opened.  
Tampering with electrical connections  
or components and mechanical parts is  
highly dangerous to the user, and can  
cause operational faults.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warning and Safety instructions  
Do not connect the appliance to the  
Using at the same time as other  
~
mains electricity supply by a  
multi-socket unit or an extension lead.  
These do not guarantee the required  
safety of the appliance (e.g. danger of  
overheating).  
heating appliances that depend on  
the air from the room  
Warning - danger of toxic fumes  
For appliances with an external fan  
~
motor fitted (...EXT models) the  
connection of the two units must be  
made using the connection cable and  
the plug connectors.  
These models may only be combined  
with a Miele external motor.  
This appliance must not be used in  
~
a non-stationary location (e.g. on a  
Great care should be taken when  
ship).  
~
using the cooker hood at the same time  
and in the same room or area of the  
house as another heating appliance  
which depends on the air in the room.  
Such appliances include gas, oil, wood  
or coal-fired boilers and heaters,  
continuous flow or other water heaters,  
gas hobs, cookers or ovens which draw  
air in from the room and duct exhaust  
gases out through a chimney or  
extraction ducting.  
In areas which may be subject to  
~
infestation by cockroaches or other  
vermin, pay particular attention to  
keeping the appliance and its  
surroundings in a clean condition at all  
times. Any damage which may be  
caused by cockroaches or other vermin  
will not be covered by the guarantee.  
When used in extraction mode, with or  
without an external motor fitted, the  
appliance draws air in from the room in  
which it is installed and from  
neighbouring rooms.  
If there is insufficient air, an  
underpressure will occur. The heating  
appliance may be starved of oxygen,  
impairing combustion.  
Harmful gases could be drawn out of  
the chimney or extraction ducting back  
into the room, with potentially fatal  
consequences.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warning and Safety instructions  
In order to ensure safe operation, and  
to prevent gases given off by the  
heating appliances from being drawn  
back into the room when the cooker  
hood and the heater are in operation  
simultaneously, an underpressure of  
0.04 mbar (4 pa) is the maximum  
permissible in the room.  
Ventilation can be maintained by air  
inlets which must not be blocked, in  
windows, doors and outside wall vents,  
or by other technical measures, such  
as ensuring that the cooker hood can  
only be switched on when the heating  
appliance is switched off or vice versa.  
A ventilation brick alone is not generally  
sufficient to ensure safe ventilation.  
,The overall ventilation condition  
of the dwelling must be taken into  
account. If in any doubt, the advice  
of a competent builder or, for gas, a  
qualified gas fitter (GasSafe  
registered in the UK) must be  
sought.  
If the hood is being operated in  
recirculation mode, the above  
restrictions do not apply.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warning and Safety instructions  
Correct use  
The cooker hood can get very hot  
~
during cooking due to heat rising from  
Never use an open flame beneath  
~
the hob.  
the cooker hood. To avoid the danger  
of fire, do not flambé or grill over an  
open flame.  
Do not touch the housing or the grease  
filters until the cooker hood has cooled  
down.  
When switched on, the cooker hood  
could draw flames into the filter. Fat  
particles drawn into the cooker hood  
present a fire hazard.  
Do not use a steam-cleaner to clean  
~
this appliance. Steam could reach  
electrical components and cause a  
short circuit.  
When using the cooker hood over a  
~
gas hob, ensure that any burners in use  
are always covered by a pan. Switch  
the cooking zone off when a pan is  
removed, even for a short time.  
Regulate the flame so that it does not  
burn up the sides of the pan.  
Correct installation  
Refer to the cooker or hob  
~
manufacturer's instructions as to  
whether a cooker hood may be  
operated above the cooker/hob.  
Do not allow the pans to overheat  
excessively (e.g. when using a wok).  
The cooker hood can become  
damaged when exposed to excessive  
heat.  
The minimum safety distances  
~
between the top of the cooker or hob  
and the bottom of the cooker hood  
given in the "Appliance dimensions"  
section of this booklet must be  
maintained, unless the hob  
Always switch the cooker hood on  
~
when a cooking zone is in use,  
manufacturer states that a greater  
safety distance is required.  
otherwise condensation may collect in  
the hood, which could cause corrosion.  
If more than one cooking appliance is  
fitted beneath the cooker hood, and  
they have different minimum safety  
distances to the cooker hood, select  
the greater distance.  
When cooking with oil or fat, chip  
~
pans and deep fat fryers etc, do not  
leave the pans unattended. Never leave  
an open grill unattended when grilling.  
Overheated oil and fat can ignite and  
could set the cooker hood on fire.  
Safety regulations prohibit the fitting  
~
of a cooker hood over solid fuel stoves.  
Do not use the cooker hood without  
~
the filters in place. This way you will  
avoid the risk of grease and dirt getting  
into the appliance and hindering its  
smooth operation.  
The filters should be regularly  
~
cleaned or changed as appropriate.  
Saturated filters are a fire hazard. See  
"Cleaning and care".  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warning and Safety instructions  
All ducting, pipework and fittings  
~
must be of non-flammable material.  
These can be obtained from the Miele  
Spare Parts department or from  
builders' merchants.  
The appliance must not be  
~
connected to a chimney or vent flue  
which is in use. Neither should it be  
connected to ducting which ventilates  
rooms with fireplaces.  
If exhaust air is to be extracted into  
~
a chimney or ventilation duct no longer  
used for other purposes, seek  
professional advice.  
Accessories  
Only use genuine Miele spare parts  
~
and accessories with this appliance. If  
spare parts or accessories from other  
manufacturers are used, this will  
invalidate the guarantee, and Miele  
cannot accept liability.  
The manufacturer cannot be held  
liable for damage caused by  
non-compliance with these Warning  
and Safety instructions.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Description of the functions  
The cooker hood works with  
. . . air extraction:  
. . . air recirculation:  
(air recirculation conversion kit  
required)  
The air is drawn in, cleaned by the  
grease filter and then directed outside.  
The air is drawn in and cleaned first by  
the grease filter and then by a charcoal  
filter. The cleaned air is then  
If the on-site ventilation system does  
not have a non-return flap, then the  
non-return flap supplied with the  
appliance must be fitted in the exhaust  
socket in the motor unit.  
recirculated back into the kitchen.  
Charcoal filters are available to order  
through your Dealer or the Miele Spare  
Parts Department or via the internet on  
for contact details and "Technical Data"  
for model number).  
Having a non-return flap fitted in the  
ducting ensures that air, once ducted  
to the outside, cannot get back into the  
room again.  
Before using the cooker hood in  
recirculation mode, ensure that the  
charcoal filter is in place; see  
"Cleaning and care".  
The flap is closed when the cooker  
hood is switched off.  
When the cooker hood is switched on,  
the non-return flap opens for the  
cooking vapours to be blown directly  
outside.  
. . . an external motor:  
(EXT models only)  
The EXT models are designed to be  
connected to an external motor located  
outside the room.  
The external motor is connected to the  
cooker hood by means of a control  
cable, and is operated by the controls  
on the cooker hood.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Description of the appliance  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Description of the appliance  
aExhaust socket C 150 mm  
bControls  
cGrease filter  
dPull-out deflector plate  
eHob lighting  
fCharcoal filter  
(extra accessory available to order  
for recirculation mode)  
gDrop-down front panel  
A lightshield to match your kitchen  
furniture may be fitted instead of this  
panel.  
hOn/Off touch control for the fan  
iTouch controls to select the fan  
power level  
jTouch control for hob illumination  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
The cooker hood is operated by pulling To switch the fan off  
out and pushing in the deflector plate.  
^ Push the deflector plate back in. The  
next time the deflector plate is pulled  
out, the cooker hood will operate at  
power level 2 again.  
To switch the fan on  
^ Pull out the deflector plate.  
The fan will come on at power level 2.  
The K symbol and Fan setting 2 will  
light up.  
or  
^ Press the On/Off touch control K for  
the fan  
All the indicator lamps will go out.  
To select a power level  
^ To select a lower power level, press  
the symbol, or to select a higher  
power level, press the + symbol.  
To switch the hob lighting on  
^ Pull the deflector plate out.  
or  
Depending on the intensity of the  
cooking vapours, levels 1 to 3 are  
usually sufficient for normal cooking.  
^ Press the hob illumination touch  
control I.  
When the lighting is switched on, the I  
indicator lamp lights up.  
Intensive setting  
^ For short periods of strong vapours  
and cooking odours, e.g. whilst  
searing meat, select the IS or  
Intensive setting.  
To switch the hob lighting off  
^ Push the deflector plate back in.  
or  
Pull the deflector plate out to its full  
extent to gain maximum extraction  
whilst avoiding excessive noise  
levels.  
^ Press the hob illumination touch  
control I.  
The indicator lamp will go out.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
Automatic switch-off of the Intensive Safety switch-off  
setting  
Should the cooker hood be left on, the  
You can set the Intensive setting so that fan will switch off automatically after 10  
it always only runs for 10 minutes  
hours. The lighting will remain on.  
before reverting automatically to level 3.  
^ Pressing the On/Off control K will  
switch the fan back on again.  
^ To set this option, both the fan and  
the hob lighting must be switched off  
and the deflector plate pushed in.  
^ Press the and + controls at the  
same time for approx. 10 seconds  
until the indicator lamp for power  
level 1 lights up.  
^ Then press in turn:  
– the hob lighting control I,  
– the control , and  
– the hob lighting control I again.  
If Automatic switch-off is not activated,  
1 and IS will flash.  
^ Press the + control to activate Auto-  
matic switch-off.  
Fan power levels 1 and IS will now  
light up constantly.  
Press the control to deactivate the  
Automatic switch-off function.  
^ Press the On/Off K control to  
confirm.  
^ If you do not confirm within 4  
minutes, the cooker hood will  
automatically revert to the original  
setting.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning and care  
Avoid:  
,Before any cleaning or  
maintenance work is carried out,  
disconnect the cooker hood from the  
mains supply.  
– cleaning agents containing soda,  
acids, chlorides or solvents,  
– abrasive cleaning agents, e.g.  
powder cleaners or cream cleaners  
and abrasive sponges, as well as pot  
scourers or sponges which have  
been used previously with abrasive  
cleaning agents. These will damage  
the surface material.  
,Exercise caution when changing  
halogen lamps. They get very hot  
during use and remain hot for some  
time after being switched off. The  
hot lamps are also susceptible to  
damage from damp cleaning. Wait a  
few minutes after switching off  
Important for appliances with  
stainless steel housing  
before commencing cleaning.  
(This infomation does not apply to the  
controls).  
Stainless steel surfaces can be cleaned  
using the Miele E-Cloth or with a  
suitable, non-abrasive, proprietary  
cleaning agent for stainless steel,  
following the manufacturer's  
Housing  
General  
instructions on the packaging.  
The surfaces and controls are  
susceptible to scratches and  
abrasion. Please observe the  
following cleaning instructions.  
To help prevent re-soiling, Miele  
conditioning agent for stainless steel  
can also be used. Follow the  
instructions on the packaging.  
^ All external surfaces and controls can  
be cleaned using a Miele E-Cloth or  
with warm water and a little  
washing-up liquid applied with a well  
wrung-out soft sponge or cloth.  
^ Wipe the surfaces dry using a soft  
cloth.  
Do not use too much water when  
cleaning the controls. Water could  
penetrate into the electronics and  
cause damage.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning and care  
Controls  
The controls may suffer  
discolouration or damage if soiling is  
left on them for too long. Remove  
soiling straight away.  
Observe the General notes on cleaning  
earlier in this section.  
When removing the grease filter do  
not tilt it downwards at an angle.  
Do not use stainless steel cleaning  
agent on the controls.  
^ Push the deflector plate in.  
Grease filter  
The re-usable metal grease filter in the  
appliance removes solid particles from  
the kitchen vapours (grease, dust, etc)  
preventing soiling of the cooker hood.  
To avoid a build-up of fat, it should be  
cleaned every 3-4 weeks on average,  
but sooner if necessary.  
,An oversaturated filter is a fire  
hazard.  
^ Then grip the front of the deflector  
plate and hold the grease filter  
securely. Whilst holding the grease  
filter pull the deflector plate out as  
illustrated above.  
^ Then lower the filter downwards and  
off.  
To avoid damaging the filter or the  
hob below, make sure you hold the  
filter securely at all times when  
handling it.  
^ Switch off the fan.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning and care  
Cleaning the grease filter by hand  
^ After cleaning, leave the filter to dry  
for a while on an absorbent surface  
before putting it back in place.  
^ Clean the filter with a soft nylon brush  
in a mild solution of hot water and a  
little washing-up liquid.  
^ When removing the filter for cleaning,  
also clean off any residues of oil or  
fat from the now accessible housing  
to prevent the risk of these catching  
fire.  
Do not use "neat" washing-up liquid.  
Do not use:  
– cleaning agents containing  
descaling agents,  
– powder cleaners, cream cleaners or  
abrasive all-purpose cleaners.  
– oven sprays.  
Cleaning the grease filter in the  
dishwasher  
^ Place the filter as upright as possible  
in the lower basket, with the short  
sides upright. Make sure that the  
spray arm can move freely.  
^ Select a programme with a maximum  
temperature of 65° C. If a Miele  
dishwasher is being used, select the  
Sensor wash programme.  
^ When putting it back, make sure that  
the red plastic guides are at the  
front and facing upwards.  
^ Use a mild dishwasher detergent.  
^ Fit the grease filter in the front of the  
deflector plate, press it upwards and  
push it in together with the deflector  
plate. It will slide onto the fixing pins  
at the back. Finally, push the grease  
filter back a little more.  
Depending on dishwasher detergent  
used, cleaning the filters in a  
dishwasher can cause permanent  
discolouration to the surface.  
However, this will not affect the  
functioning of the filters in any way.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning and care  
Fitting and replacing the  
charcoal filters  
If the cooker hood is connected for  
recirculation, a charcoal filter (optional  
accessory) must be inserted in addition  
to the grease filter.  
This is designed to absorb cooking  
smells.  
It is fitted in the canopy above the  
grease filter.  
Replacement charcoal filters can be  
obtained from your dealer, Miele or via  
See back cover for contact details,  
and "Technical data" for type and  
reference number.  
Follow the instructions supplied with the  
charcoal filter when fitting it.  
Replace the charcoal filter at least  
every six months or more frequently if  
necessary.  
Used charcoal filters can be disposed  
of with the normal household waste.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning and care  
Changing a halogen lamp  
^ Pull out the deflector plate, and  
remove the grease filter as described  
earlier.  
^ Switch off the fan and the lighting.  
,Exercise caution when changing  
halogen lamps. They get very hot  
during use, and remain hot for some  
time after being switched off. Do not  
touch the surface directly when  
changing a lamp, as grease  
particles from your fingers will  
adhere to the surface and damage  
it. Please follow the manufacturer’s  
instructions.  
^ Push down the lighting unit slightly  
^ Remove the charcoal filter if the  
cooker hood is being used in  
recirculation mode.  
via the opening in the safety panel.  
^ The halogen lamp is now accessible  
to be unscrewed anti-clockwise.  
Before any cleaning or maintenance  
work, disconnect the cooker hood  
from the mains supply.  
^ Replace it with a new halogen lamp  
(specification: GU/GZ 10, 230 V,  
50 W). Screw the lamp into the  
socket and push it upwards.  
Please follow the manufacturer's  
instructions.  
^ Replace the grease filter and, if being  
used in recirculation mode, the  
charcoal filter.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
After Sales Service  
In the event of a fault which you cannot  
correct yourself, or if the appliance is  
under guarantee, please contact:  
Guarantee  
For information on the appliance  
guarantee specific to your country  
please contact Miele. See back cover  
for contact details.  
– Your Miele Dealer / Chartered Agent  
or  
In the U.K. your appliance is  
– The Miele Service Department (see  
back cover for address).  
guaranteed for 2 years from the date of  
purchase. However, you must activate  
your cover by calling 0845 365 6640 or  
When contacting your Dealer or Miele,  
please quote the model and serial  
number of your appliance. These are  
shown on the data plate which is visible  
when the grease filter is removed.  
For the U.K.: Please note that  
telephone calls may be monitored  
and recorded for training purposes.  
N.B. A call-out charge will be applied  
for service visits where the problem  
could have been resolved as described  
in these instructions.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appliance dimensions  
DA 3460  
DA 3480  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appliance dimensions  
4) Recirculation mode requires  
installation kit DUU 151.  
5) Optional DSM 400  
* Installation is also possible in a  
600 mm wide unit.  
* Installation is also possible in a  
762 mm wide unit.  
Safety distance between hob and  
cooker hood  
The following distance must be  
maintained between the top of the  
cooker/hob and the bottom of the  
cooker hood unless a greater  
distance is specified by the  
manufacturer of the cooker or hob:  
above electric hobs and cookers  
450 mm  
above electric barbecue grilles and  
deep fat fryers 650 mm  
above gas hobs and cookers  
650 mm  
If this cooker hood is installed above  
a Miele Wok CS 1028 CombiSet  
appliance, a minimum safety  
DA 3490  
1) The front section of the wall housing  
unit must be fitted with a shelf to the  
depth of the partition wall.  
distance of 760 mm must be  
maintained between the burner and  
the lower edge of the cooker hood.  
If the appliance is fitted further back,  
e.g. to accomodate a front panel, then  
the shelf depth should be  
See “Warning and Safety  
correspondingly deeper.  
instructions” for further information.  
2) The partition wall in the wall unit must  
be removable.  
3) In extraction mode: when measuring  
for the height of the wall housing unit  
and the cut-out, account must be taken  
of any accessories fitted, e.g. silencer,  
DSM module.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Installation accessories  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
a1 exhaust connection  
for exhaust ducting C 150 mm.  
b1 reducing collar  
for exhaust ducting C 125 mm.  
14 screws 4 x 15 mm  
for securing the cooker hood into the  
wall unit.  
c1 non-return valve  
for fitting into the exhaust connection  
(not for recirculation mode).  
d2 brackets  
to support the appliance in the wall  
unit.  
8 screws M4 x 12 mm  
for securing the cooker hood to the  
brackets.  
e1 spacer strip  
to conceal the gap between the rear  
of the appliance and the wall.  
4 of the screws can be used instead of  
the plastic rivets to secure the spacer  
strip.  
fConversion kit for recirculation  
mode  
including exhaust grille and flexible  
aluminium hose with clip (this is not  
included, but is available as an  
optional extra - see Technical Data).  
4 plastic rivets  
for securing the spacer strip to the  
back of the appliance.  
gDML 400 installation kit  
(optional accessory)  
contains hinging and screws for  
fixing a lightshield to match kitchen  
furniture (lightshield not supplied with  
cooker hood)  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Positioning the appliance in  
the wall housing unit  
To position the appliance correctly,  
cut the spacer strip to required depth  
T, and then attach it to the back of  
the appliance.  
T= Depth of carcase K minus depth of  
^ Screw the spacer strip underneath  
the housing unit sides, flush with the  
rear wall.  
appliance G  
^ Example a shows the installation  
without a front panel fitted and with  
the front edge of the deflector plate  
flush with the front edge of the  
furniture housing unit. This installation  
needs a shelf 95 mm deep.  
^ Example b shows the installation  
with a front panel to match the  
kitchen furniture. This installation  
requires dimension b for the front  
panel plus 5 mm for the DML 400  
fixing kit to be added to the shelf  
dimension (95 mm + 5 mm +  
dimension b).  
^ Draw a vertical line up both inside  
walls of the housing from the front of  
the spacer strip.  
The remaining installation gap must be  
at least 180 mm in depth.  
If it is less than 180 mm, position the  
appliance further back, and reduce  
measurement T accordingly.  
The position of the deflector plate can  
be adjusted in depth by a maximum of  
35 mm at the front.  
^ Cut the spacer strip supplied to  
measurement T.  
Score along the groove for the  
smaller measurement as shown, and  
remove the surplus.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Do not remove the protective film  
between the deflector plate and the  
casing until the hood has been  
placed in the housing unit.  
^ Screw the brackets onto the right and  
left inside walls of the housing unit as  
shown. The back edge of the  
Installation of the cooker hood is  
carried out without the grease filter  
fitted in position. If the grease filter has  
already been fitted, then remove it as  
follows before installing the cooker  
hood (see “Cleaning and care”).  
brackets should align with the vertical  
line drawn up from the front of the  
spacer strip, and the lower edge  
aligned with the lower edge of the  
housing unit side wall.  
The brackets are designed for 16  
and 19 mm thick carcase sides.  
Orientate the bracket so that the  
vertical depth matches the thickness  
of the panel, as shown.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Note for dismantling the cooker hood:  
Undoing the screws on the left and  
right inside the housing releases the  
brackets, allowing the appliance to  
be removed from the unit.  
^ When fitting an 80 cm or a 90 cm  
appliance into a 60 cm unit, unscrew  
the brackets on the deflector plate  
whilst it is pulled out.  
^ Push the cooker hood back against  
the spacer strip.  
^ Pull out the deflector plate.  
^ Secure the appliance to the brackets  
using two screws on each side.  
^ Lift the appliance up into the housing  
from below, and engage in the  
brackets.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Attaching the lightshield  
^ Attach the lightshield (if using).  
A DML 400 installation kit, available as  
an optional accessory, is required for  
this (available as a special accessory).  
Follow the installation instructions  
supplied.  
^ Remove the protective film between  
the deflector plate and the casing.  
^ Secure the front of the appliance to  
the floor of the housing unit from  
below using 4 screws (6 screws for  
90 cm wide cooker hood).  
Weight of a lightshield matching  
existing furniture  
To avoid damaging the deflector plate  
when it is pulled out, care should be  
taken to screw the fixing screws in  
straight, and to ensure that the  
The lightshield must not exceed 1300 g  
in weight.  
This applies to lightshields with a depth  
of up to 30 mm.  
screwheads are countersunk.  
For larger or heavier lightshields, the  
weight must be reduced by e.g.  
machining it away at the back.  
^ Secure the spacer strip to the back of  
the appliance from behind using  
4 plastic rivets as shown.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Aligning the deflector plate  
Fitting the grease filter  
^ Remove the protective strip around  
the edge of the grease filter.  
Fit the grease filter.  
^ To do this, pull the deflector plate  
out.  
^ The position of the deflector plate  
can be brought forward by up to  
35 mm using the adjusting screws on  
either side of the deflector plate.  
Align the deflector plate to the front of  
the kitchen furniture units on either  
side.  
^ Turn the grease filter so that the red  
plastic guides are at the front and  
facing upwards.  
^ Fit the grease filter in the front of the  
deflector plate, press it upwards and  
push it in together with the deflector  
plate. It will slide onto the fixing pins  
at the back. Finally, push the grease  
filter back a little more.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Vent ducting  
^ If the on-site ventilation system does  
not have a non-return flap, then the  
non-return flap supplied with the  
appliance must be fitted in the  
^ When using C 150 mm ducting,  
exhaust socket in the motor unit.  
secure the exhaust connection  
supplied to exhaust ducting with  
hose clips.  
^ If using C 125 mm ducting, fit the  
reducing collar into the exhaust  
connection, and secure the exhaust  
ducting to the reducing collar with a  
hose clip. (See "Connection for air  
extraction").  
^ Place the exhaust ducting on the fan  
connection for the cooker hood.  
^ See "Connection for air extraction" for  
further instructions on fitting the  
ducting.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Setting up for recirculation  
mode  
^ Make sure that the slats in the  
exhaust grille point towards the  
centre of the room and not towards a  
wall or the ceiling.  
If site conditions are not suitable for the  
cooker hood to be used with air  
extraction, the appliance must be set  
up for recirculation.  
A non-return flap is not used in  
recirculation mode.  
^ Fit the charcoal filter (see “Cleaning  
and care”).  
Electrical connection  
Refer to the notes in “Electrical  
connection” and “Warning and  
Safety instructions” before  
connecting to the electricity supply.  
^ For appliances connected to an  
external motor (EXT models):  
Connect the cooker hood to the  
external motor using the connecting  
cable and the 6-pole plug connector.  
^ Separate fitting instructions are  
supplied with the external motor.  
For this, conversion kit DUU 151  
(available from your Miele dealer or the  
Miele Spare Parts Dept.) is required.  
You will also need a charcoal filter (see  
“Technical data”).  
^ Fit the conversion kit as described in  
the installation instructions supplied  
with the kit.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connection for air extraction  
– Only use smooth pipes or flexible  
hoses made from non-flammable  
materials for the extraction ducting.  
Important: To avoid the danger of  
toxic fumes, please observe the  
Warning and Safety instructions.  
This is especially crucial when using  
the cooker hood at the same time as  
another heating appliance which  
relies on air from the same room.  
The cooker hood should be installed  
according to local and national  
building regulations. Seek approval  
from the building inspector where  
necessary.  
– When using an external motor, make  
sure that the exhaust ducting is  
sufficiently rigid. The external motor  
can cause an underpressure which  
can result in the exhaust ducting  
distorting.  
To achieve the greatest possible air  
extraction with the lowest noise level,  
please note the following:  
– To ensure efficient air extraction, the  
diameter of the exhaust ducting  
should not be less than 150 mm.  
– If flat ducting is being used, the  
cross-section must not be smaller  
than the cross-section of the exhaust  
connection.  
– All ducting, pipework and fittings  
must be of non-flammable materials.  
– The exhaust ducting should be as  
short and straight as possible.  
– Only use wide radius bends.  
– The exhaust ducting should not be  
kinked or compressed.  
– Ensure that all connections are  
strong and airtight.  
– Where ducting is horizontal, it must  
be laid to slope away at at least 1 cm  
per metre. This is to ensure that  
condensate cannot drain back into  
the cooker hood.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connection for air extraction  
– If the exhaust air is to be ducted into Condensate trap  
the open air, the installation of a  
(optional accessory)  
telescopic wall vent or roof vent  
(available as an optional accessory)  
is recommended.  
– If the exhaust air is to be ducted into  
a vent flue, the ducting must be  
directed in the flow direction of the  
flue.  
In addition to insulating the exhaust  
Important:  
ducting, we recommend that a suitable  
condensate trap is also installed to  
collect and evaporate any condensate  
which may occur. Condensate traps  
are available for C 125 mm or  
If the exhaust ducting is to run through  
rooms, ceiling space etc. where there  
may be great variations in temperature  
between the different areas, the  
problem of condensation will need to  
be addressed. The exhaust ducting will  
need to be suitably insulated.  
C 150 mm ducting.  
When installing a condensate trap,  
ensure that it is positioned vertically  
and if possible directly above the  
exhaust connection. The arrow on the  
housing indicates the direction of  
air-flow.  
Cooker hoods designed for use with an  
external motor (...EXT models) have an  
integrated condensate trap.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connection for air extraction  
Silencer  
...with air extraction:  
(optional accessory)  
The silencer not only reduces noise  
from the fan, but also sounds from  
outside (e.g. traffic noise).  
For this reason the silencer must be  
positioned as close as possible to the  
ducting exit a.  
...in recirculation mode:  
The silencer needs to be positioned  
between the fan and the exhaust grille  
b. The space needs to be checked in  
some cases.  
To achieve even further reductions in  
noise levels, a special silencer can be  
fitted in the ducting system.  
...air extraction with external motor:  
To minimise noise from the motor in the  
kitchen, the silencer should be  
positioned in front of the external motor  
c if possible, or if the ducting is long,  
then in the ducting inside the cooker  
hood itself d.  
In the case of an external motor placed  
inside the house, fitting a silencer  
behind the external motor e reduces  
the noise of the motor outside the  
house.  
In all modes of operation, the most  
effective noise reductions are  
achieved if two silencers are fitted  
one behind the other in the system.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical connection  
If the switch is not accessible after  
installation (depending on country), an  
additional means of disconnection must  
be provided for all poles.  
All electrical work should be  
undertaken by a suitably qualified  
and competent person in strict  
accordance with current national  
and local safety regulations  
(BS 7671 in the UK).  
For extra safety it is advisable to protect  
the appliance with a suitable residual  
current device (RCD). Contact a  
qualified electrician for advice.  
Installation, repairs and other work  
by unqualified persons could be  
dangerous, for which the  
Important  
This appliance is supplied for  
connection to an a.c. 230 V single  
phase 50 Hz supply.  
manufacturer cannot be held liable.  
Ensure power is not supplied to the  
appliance until after installation or  
repair work has been carried out.  
The wires in the mains lead are  
coloured in accordance with the  
following code:  
Do not connect the appliance to the  
mains electricity supply by an  
extension lead. These do not  
guarantee the required safety of the  
appliance.  
Green/yellow = earth  
Blue  
= neutral  
= live  
Brown  
WARNING:  
THIS APPLIANCE MUST BE  
EARTHED  
The connection data is given on the  
data plate. This is visible when the  
grease filters have been removed.  
Ensure that this data matches the  
household mains supply.  
Connection of this appliance should be  
made via a suitable isolator or a double  
pole fused spur connection unit which  
complies with national and local safety  
regulations and the On-Off switch  
should be easily accessible after the  
appliance has been built in.  
When switched off there must be an  
all-pole contact gap of 3 mm in the  
switch (including switch, fuses and  
relays according to EN 60335).  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation with Control module DSM 400  
The Miele DSM 400 control module can Components used in the central  
be used to combine the cooker hood  
with other components.  
ducting system are not supplied by  
Miele.  
It enables the following:  
If in any doubt, the advice of a  
competent builder or, for gas, a Gas  
Safe installer must be sought.  
Potential free connection  
This can be used to operate a further  
appliance via the On/Off button s of  
the cooker hood.  
Connection to a light switch  
The control module can be used to  
switch on the cooker hood lighting via a  
push button light switch in the house.  
Installation  
The control module must be installed  
above the cooker hood housing.  
The potential free contact on the  
DSM 400 a can, for example, be used  
in a cooker hood with an external motor  
...EXT, which is connected to a central  
ducting system.  
The electrical connection of  
components to the control module  
must be carried out by a suitably  
qualified and competent person.  
The contact can then be used to  
operate an electrically driven non-return  
flap b which is connected to the  
central extraction unit c.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical data  
Connected load* . . . . . . . . . . . . . 280 W * For ...EXT models the connected load  
Fan motor*. . . . . . . . . . . . . . . . . 180 W and extraction power will depend on  
Hob lighting . . . . . . . . . . . . . . 2 x 50 W the type of external motor fitted.  
Voltage . . . . . . . . . . . . . . . . . AC 230 V EXT models:  
Length of connection cable to external  
Frequency . . . . . . . . . . . . . . . . . . 50 Hz  
motor. . . . . . . . . . . . . . . . . . . . . . . 1.9 m  
Fuse rating . . . . . . . . . . . . . . . . . . . . 5 A  
Electrical cable  
length . . . . . . . . . . . . . . . . . . . . . . 1.5 m  
Weight  
DA 3460 . . . . . . . . . . . . . . . . . . . . 12 kg  
DA 3460 EXT . . . . . . . . . . . . . . . . 10 kg  
DA 3480. . . . . . . . . . . . . . . . . . . 13.5 kg  
DA 3490 . . . . . . . . . . . . . . . . . . . . 14 kg  
DA 3490 EXT . . . . . . . . . . . . . . . . 12 kg  
Fan performance*  
Extraction power according to EN  
61591  
Extraction system ø 150 mm:  
Level I . . . . . . . . . . . . . . . . . . . 150 m3/h  
Level 2. . . . . . . . . . . . . . . . . . . 275 m3/h  
Level 3. . . . . . . . . . . . . . . . . . . 400 m3/h  
Intensive setting . . . . . . . . . . . 550 m3/h  
Recirculation power with charcoal  
filters:  
Level I . . . . . . . . . . . . . . . . . . . . 80 m3/h  
Level 2. . . . . . . . . . . . . . . . . . . 180 m3/h  
Level 3. . . . . . . . . . . . . . . . . . . 280 m3/h  
Intensive setting . . . . . . . . . . . 350 m3/h  
Optional accessories for  
recirculation mode:  
- Conversion Kit DUU 151  
- Miele charcoal filter DKF 13-1  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Alteration rights reserved / 0613  
M.-Nr. 09 190 950 / 05  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Minicom Advanced Systems Switch 216 User Manual
MTD Tiller 215 370A User Manual
Multiquip Saw FS 1 User Manual
Multi Tech Systems Network Card RF820 User Manual
Nady Systems Speaker System FWA15 User Manual
NeumannBerlin Microphone U 87 i User Manual
Olympus Camera Accessories BLS 1 User Manual
Oreck Vacuum Cleaner U3771 User Manual
Panasonic CD Player CQ RDP472N User Manual
Panasonic Digital Camera DMC FH10 User Manual