Meyer Sound Car Speaker acheron designer screen channel loudspeaker User Manual

OPERATING INSTRUCTIONS  
Acheron® Designer Screen Channel Loudspeaker  
Keep these important operating instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYMBOLS USED  
These symbols indicate important safety or operating features in this booklet and on the chassis:  
!
Dangerous voltages: risk of  
electric shock  
Important operating instructions  
Frame or chassis  
Masse, châssis  
Protective earth ground  
Terre de protection  
Masse Schutzleiter  
Tierra proteccionista  
Pour indiquer les risques  
résultant de tensions dangereuses  
Pour indequer important  
instructions  
Wichtige Betriebsanweisung oder  
Gebrauchsanleitung  
Warnung vor gefährlicher  
elektrischer Spannung  
Rahmen oder Gehäuse  
Armadura o chassis  
Para indicar voltajes peligrosos  
Instrucciones importantes de  
funcionamiento y/o manteniento  
IMPORTANT SAFETY INSTRUCTIONS  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
11.Only use attachments/accessories specified by Meyer  
Sound.  
12.If applicable, use only with the caster rails or rigging  
specified by Meyer Sound, or sold with the loudspeaker.  
Handles are for carrying only.  
4. Follow all instructions.  
5. Do not use this loudspeaker near water.  
6. Clean only with dry cloth.  
CAUTION: Rigging should only be done by  
experienced professionals.  
!
7. Do not block any ventilation openings. Install in accor-  
dance with Meyer Sound’s installation instructions.  
13.Unplug this loudspeaker during lightning storms or when  
unused for long periods of time.  
8. Do not install near any heat sources such as radiators,  
heat registers, stoves, or other apparatus that produce  
heat.  
14.Disconnect the mains plug before disconnecting the  
power cord from the loudspeaker.  
15.Refer all servicing to qualified service personnel. Servic-  
ing is required when the loudspeaker has been damaged  
in any way, such as when the power-supply cord or plug  
has been damaged; liquid has been spilled or objects  
have fallen into the loudspeaker; rain or moisture has  
entered the loudspeaker; the loudspeaker has been  
dropped; or when for undetermined reasons the loud-  
speaker does not operate normally.  
9. Do not defeat the safety purpose of the grounding-type  
plug. A grounding type plug has two blades and a third  
grounding prong. The third prong is provided for your  
safety. If the provided plug does not fit into your outlet,  
consult an electrician for replacement of the obsolete  
outlet.  
10.Protect the power cord from being walked on or pinched,  
particularly at plugs, convenience receptacles, and the  
point where they exit from the loudspeaker. The AC  
mains plug or appliance coupler shall remain readily  
accessible for operation.  
CAUTION: To reduce the risk of electric shock,  
do not expose this loudspeaker to rain or mois-  
!
ture. Do not install the loudspeaker in wet or humid  
locations without using weather protection equip-  
ment from Meyer Sound.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY SUMMARY  
English  
Ne pas installer l’haut-parleur dans un  
endroit où il y a de l’eau ou une  
humidité excessive.  
Um ein Überhitzen dem Lautsprecher  
zu verhindern, das Gerät vor direkter  
Sonneneinstrahlung fernhalten und  
nicht in der Nähe von wärmeabstrahlen-  
den  
To reduce the risk of electric shock, dis-  
connect the loudspeaker from the AC  
mains before installing audio cable.  
Reconnect the power cord only after  
making all signal connections.  
Ne pas laisser de l’eau ou tout objet  
pénétrer dans l’haut-parleur. Ne pas  
placer de r´cipients contenant un liquide  
sur cet appareil, ni à proximité de celui-  
ci.  
Haushaltsgeräten (z.B. Heizgerät oder  
Herd) aufstellen.  
Connect the loudspeaker to a two-pole,  
three-wire grounding mains receptacle.  
The receptacle must be connected to a  
fuse or circuit breaker. Connection to  
any other type of receptacle poses a  
shock hazard and may violate local  
electrical codes.  
Im Inneren diesem Lautsprecher herr-  
schen potentiell gefährliche Spannun-  
gen. Nicht versuchen, das Gerät zu öff-  
nen. Es enthält keine vom Benutzer  
reparierbaren Teile. Reparaturen dürfen  
nur von ausgebildetem Kundenienst-  
personal durchgeführt werden.  
Pour éviter une surchauffe de l’haut-  
parleur, conserver-la à l’abri du soleil.  
Ne pas installer à proximité d’appareils  
dégageant de la chaleur tels que radia-  
teurs ou appareils de chauffage.  
Ce haut-parleur contient des circuits  
haute tension présentant un danger. Ne  
jamais essayer de le démonter. Il n’y a  
aucun composant qui puisse être  
réparé par l’utilisateur. Toutes les répa-  
rations doivent être effectuées par du  
personnel qualifié et agréé par le con-  
structeur.  
Do not install the loudspeaker in wet or  
humid locations without using weather  
protection equipment from Meyer  
Sound.  
Español  
Para reducir el riesgo de descarga eléc-  
Do not allow water or any foreign object  
to get inside the loudspeaker. Do not  
put objects containing liquid on or near  
the unit.  
trica, desconecte de la red de voltaje el  
altoparlante antes de instalar el cable  
de señal de audio. Vuelva a conectar la  
alimentacion de voltaje una vez efec-  
tuadas todas las interconexiones de  
señalizacion de audio.  
To reduce the risk of overheating the  
loudspeaker, avoid exposing it to direct  
sunlight. Do not install the unit near  
heat-emitting appliances, such as a  
room heater or stove.  
Deutsch  
Um die Gefahr eines elektrischen  
Conecte el altoparlante a un tomacorri-  
ente bipolar y trifilar con neutro de  
puesta a tierra. El tomacorriente debe  
estar conectado a la protección de deri-  
vación apropiada (ya sea un fusible o un  
disyuntor). La conexión a cualquier otro  
tipo de tomacorriente puede constituir  
peligro de descarga eléctrica y violar los  
códigos eléctricos locales.  
Schlages auf ein Minimum zu reduzie-  
ren, den Lautsprecher vom Stromnetz  
trennen, bevor ggf. ein Audio-Schnitt-  
stellensignalkabel angeschlossen wird.  
Das Netzkabel erst nach Herstellung  
aller Signalverbindungen wieder ein-  
stecken.  
This loudspeaker contains potentially  
hazardous voltages. Do not attempt to  
disassemble the unit. The unit contains  
no user-serviceable parts. Repairs  
should be performed only by factory-  
trained service personnel.  
Der Lautsprecher an eine geerdete  
zweipolige Dreiphasen-Netzsteckdose  
anschließen. Die Steckdose muß mit  
einem geeigneten Abzweigschutz  
(Sicherung oder Leistungsschalter) ver-  
bunden sein. Der Anschluß der unter-  
brechungsfreien Stromversorgung an  
einen anderen Steckdosentyp kann zu  
Stromschlägen führen und gegen die  
örtlichen Vorschriften verstoßen.  
No instale el altoparlante en lugares  
donde haya agua o humedad excesiva.  
Français  
No deje que en el altoparlante entre  
agua ni ningún objeto extraño. No  
ponga objetos con líquidos encima de  
la unidad ni cerca de ella.  
Pour réduire le risque d’électrocution,  
débrancher la prise principale de l’haut-  
parleur, avant d’installer le câble d’inter-  
face allant à l’audio. Ne rebrancher le  
bloc d’alimentation qu’après avoir  
effectué toutes les connections.  
Para reducir el riesgo de sobrecalenta-  
miento, no exponga la unidad a los  
rayos directos del sol ni la instale cerca  
de artefactos que emiten calor, como  
estufas o cocinas.  
Branchez l’haut-parleur dans une prise  
de courant à 3 dérivations (deux pôles  
et la terre). Cette prise doit être munie  
d’une protection adéquate (fusible ou  
coupe-circuit). Le branchement dans  
tout autre genre de prise pourrait  
entraîner un risque d’électrocution et  
peut constituer une infraction à la régle-  
mentation locale concernant les instal-  
lations électriques.  
Der Lautsprecher nicht an einem Ort  
aufstellen, an dem sie mit Wasser oder  
übermäßig hoher Luftfeuchtigkeit in  
Berührung kommen könnte.  
Este altoparlante contiene niveles de  
voltaje peligrosos en potencia. No  
intente desarmar la unidad, pues no  
contiene piezas que puedan ser repar-  
das por el usuario. Las reparaciones  
deben efectuarse únicamente por parte  
del personal de mantenimiento capac-  
itado en la fábrica.  
Darauf achten, daß weder Wasser noch  
Fremdkörper in das Innere den  
Lautsprecher eindringen. Keine  
Objekte, die Flüssigkeit enthalten, auf  
oder neben die unterbrechungsfreie  
Stromversorgung stellen.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 1: INTRODUCTION  
HOW TO USE THIS MANUAL  
ACHERON DESIGNER SCREEN CHANNEL  
LOUDSPEAKER  
Make sure to read these operating instructions in their  
entirety before configuring a loudspeaker system with  
Acheron Designer loudspeakers. In particular, pay close  
attention to material related to safety issues.  
At the heart of Meyer Sound's EXP line of cinema products  
are the Acheron® high-performance screen channel loud-  
speakers. The Acheron Designer is the most compact of the  
Acheron models, making it an excellent choice for sound  
design suites, screening rooms, private theatres, and small  
commercial theatres. Optimized for installation behind per-  
forated screens, the Acheron Designer combines the advan-  
tages of self-powered technology and innovative horn  
design to deliver exceptional, precise coverage for the left,  
center, and right screen channels for cinema.  
As you read these operating instructions, you will encounter  
the following icons for notes, tips, and cautions:  
NOTE: A note identifies an important or useful  
piece of information relating to the topic under  
discussion.  
TIP: A tip offers a helpful tip relevant to the topic  
at hand.  
CAUTION: A caution gives notice that an  
action may have serious consequences and  
!
could cause harm to equipment or personnel, and  
could cause delays or other problems.  
Information and specifications are subject to change.  
Updates and supplementary information are available at  
Meyer Sound Technical Support is available at:  
Tel: +1 510 486.1166  
Tel: +1 510 486.0657 (after hours support)  
Acheron Designer (without Optional Grille Frame)  
The Acheron Designer uses the same patent-pending horn  
technology and high-frequency compression driver as the  
other Acheron models, delivering the same 38 Hz to 17 kHz  
frequency response. This consistency of fidelity between  
Acheron models ensures that soundtracks monitored with  
the Acheron Designer translate accurately when played  
back in larger rooms with the Acheron 100, Acheron 80,  
Acheron Studio, or other calibrated cinema system.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 1: INTRODUCTION  
Designed specifically for cinema, the Acheron horn features  
a very soft roll-off beyond its 80-degree horizontal by 50-  
degree vertical coverage pattern. The extremely well-  
behaved horn ensures an accurate acoustic crossover and  
consistent vertical coverage pattern through the critical  
crossover range between the low- and high-frequency driv-  
ers. The optimized crossover point places most of the dialog  
in the horn, which is ideal for cinema applications.  
The Acheron Designer enclosure is constructed of premium  
birch plywood and coated with a low-gloss, black-textured  
finish. The cabinet bottom is fitted with two threaded M6  
attachment points for the optional MYA-DES cradle-style  
yoke, allowing the unit to be suspended from a single hang-  
ing point.  
Designed and manufactured at Meyer Sound's headquar-  
ters in Berkeley, California, the Acheron Designer’s drivers  
include one 12-inch low-frequency cone driver, housed in an  
optimally tuned, ported enclosure, and one high-frequency  
4-inch diaphragm compression driver. The drivers yield  
uncompromising quality and are powered by sophisticated  
onboard amplification. The self-powered design ensures  
consistent results and simplifies installations in both new  
and existing rooms.  
Acheron Designer with Optional MYA-DES Cradle-Style Yoke  
An optional, black cloth grille frame update kit is available  
for installations where the Acheron Designer is not placed  
behind a screen.  
Acheron Designer with Recessed Heat Sink  
A proprietary two-channel, Class-D amplifier powers each  
driver channel independently. Onboard processing includes  
driver protection circuitry, an electronic crossover, and cor-  
rection filters, ensuring flat frequency and phase responses.  
The rear-mounted, recessed heat sink yields efficient con-  
vection cooling, and allows the unit to be placed flat against  
walls, when necessary.  
The optional RMS™ remote monitoring system provides  
comprehensive monitoring of system parameters on a  
Windows®-based computer.  
Acheron Designer with Optional Grille Frame  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 2: POWER REQUIREMENTS  
The Acheron Designer combines advanced loudspeaker  
technology with equally advanced power capabilities.  
Understanding power distribution, voltage and current  
requirements, and electrical safety guidelines is critical to  
the safe operation of the Acheron Designer.  
AC Loop Output Connector (Gray)  
The gray AC Loop Output connector allows multiple  
Acheron Designers to be looped and powered from a single  
power source. Connect the AC Loop Output of the first  
Acheron Designer to the AC Input of the second unit, and so  
forth. The AC Loop Output uses a PowerCon3 AC mains lock-  
ing connector that prevents accidental disconnections.  
AC CONNECTORS  
The Acheron Designer user panel includes 3-pole, Power-  
Con AC connectors.  
The maximum number of loudspeakers that can be looped  
from the Loop Output connector is determined by the volt-  
age of the power source, the current draw of the looped  
loudspeakers, the circuit breaker rating, and the rating of the  
AC power cable connected to Acheron Designer.  
DO NOT  
DISCONNECT  
UNDER LOAD  
COMMERCIAL  
Table 1: Maximum Number of Acheron Designers that Can Be  
Looped with AC Power  
AUDIO SYSTEM  
AC INPUT  
RATING  
100-240V~  
50-60 Hz  
4A MAX  
AC LOOP  
OUTPUT  
3JKB  
100-240V~  
50-60 Hz  
8A MAX  
Class 1 Wiring  
Circuit Breaker/  
115 V AC  
230 V AC  
100 V AC  
Made in USA with domestic and foreign parts  
www.meyersound.com  
Connector Rating  
15 amps  
20 amps  
3 looped  
(4 total)  
7 looped  
(8 total)  
2 looped  
(3 total)  
AC Input (Left) and AC Loop Output (Right) Connectors  
5 looped  
(6 total)  
10 looped  
(11 total)  
3 looped  
(4 total)  
AC Input Connector (Blue)  
The blue AC Input connector supplies power to the  
Acheron Designer loudspeaker. The connector is rated at  
20 amps and uses a PowerCon3 AC mains locking connec-  
tor that prevents accidental disconnections. A 10-foot AC  
power cable, rated at 15 amps, is included with each  
Acheron Designer. If you replace the included AC power  
cable, make sure to use a cable with the appropriate power  
plug (on the other end) for the region in which you will oper-  
ate the unit.  
NOTE: The Acheron Designer current draw is  
dynamic and fluctuates as operating levels  
change. The numbers in Table 1 assume that operat-  
ing levels are normal and not such that the loud-  
speakers are constantly limiting.  
Each Acheron Designer ships with one AC looping connec-  
tor for making AC looping cables. Assembled AC looping  
cables are available from Meyer Sound.  
The AC Input connector also supplies power to any addi-  
tional loudspeakers connected to the Acheron Designer’s  
gray Loop Output connector. Each Acheron Designer loud-  
speaker requires approximately 3.24 A rms maximum at  
115 V AC and 1.74 A rms maximum at 230 V AC for proper  
operation.  
CAUTION: Do not exceed the current capabil-  
ity of the 20-amp Input connector for the  
!
Acheron Designer. When looping loudspeakers, con-  
sider the total current draw for all loudspeakers on  
the circuit, including the first loudspeaker.  
CAUTION: When using the included AC power  
cable, do not loop more than three additional  
!
Acheron Designers from the AC Loop Output con-  
nector at 115 V (four total for the circuit), and not  
more than seven at 230 V (eight total for the circuit).  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 2: POWER REQUIREMENTS  
WIRING FOR AC CONNECTIONS  
AC POWER DISTRIBUTION  
The Acheron Designer requires a grounded outlet. To oper-  
ate safely and effectively, it is extremely important that the  
entire system be properly grounded.  
All components in an audio system (self-powered loud-  
speakers, mixing consoles, and processors) must be prop-  
erly connected to an AC power distribution system to ensure  
that AC line polarity is preserved, and that all grounding  
points are connected to a single node or common point  
using the same cable gauge as the neutral and line cables.  
Blue = neutral  
Brown = hot  
NOTE: Improper grounding of connections  
between loudspeakers and the rest of the  
audio system may produce noise or hum, or cause  
serious damage to the input and output stages of the  
system’s electronic components.  
Yellow/green =  
earth ground  
(chassis)  
CAUTION: Before applying AC power to any  
!
Meyer Sound self-powered loudspeaker, make  
AC Cable Wiring Scheme  
sure that the voltage potential difference between the  
neutral and earth-ground lines is less than 5 V AC  
when using single-phase AC wiring.  
When wiring international or special-purpose AC power  
cables and connectors, use the following wiring scheme:  
Connect the blue wire to the black terminal, or the termi-  
nal marked with an N.  
Figure 1 illustrates a basic three-phase AC distribution sys-  
tem with the loudspeaker load distributed across the three  
phases. All loudspeakers are connected to common neutral  
and earth-ground lines.  
Connect the brown wire to the red terminal, or the termi-  
nal marked with an L.  
Connect the yellow and green wire to the green (or green  
and yellow) terminal, or the terminal marked with an E.  
CAUTION: When creating AC power cables  
and distribution systems, it is important to pre-  
!
serve AC line polarity and connect the earth ground  
on both ends of the cable. The Acheron Designer  
requires a grounded connection. Always use a  
grounded outlet and plug. It is extremely important  
that the system be properly grounded to operate  
safely and properly. Do not ground-lift the AC cable.  
Line 1  
Line 2  
Line 3  
Neutral  
Earth Ground  
Figure 1: AC Power Distribution System  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
ACHERON DESIGNER OPERATING INSTRUCTIONS  
ACHERON DESIGNER VOLTAGE  
REQUIREMENTS  
The Acheron Designer operates safely and continuously  
when the AC voltage stays within 100–264 V AC at 50 or  
60 Hz. The loudspeaker can withstand continuous voltages  
up to 275 volts and allows any combination of voltage to  
GND (neutral-line-ground or line-line-ground).  
POWERING UP THE ACHERON DESIGNER  
When AC power is applied to the Acheron Designer, its  
Intelligent AC™ power supply automatically selects the cor-  
rect operating voltage, allowing it to be used internationally  
without manually setting voltage switches. In addition,  
Intelligent AC provides soft-start power up, eliminating high  
inrush currents; suppresses high-voltage transients up to  
several kilovolts; filters common mode and differential mode  
radio frequencies (EMI); and sustains operation temporarily  
during low-voltage periods.  
If the voltage drops below 90 V (brownout), the unit uses  
stored power to continue operating temporarily; the loud-  
speaker shuts down if the voltage does not rise above the  
low boundary before the stored power is used.  
When powering up the Acheron Designer, the following  
startup events take place over several seconds.  
If the voltage rises above 275 V, the power supply immedi-  
ately shuts off to prevent damage to the unit.  
1. Audio output is muted.  
If the Acheron Designer shuts down due to either low or high  
voltage, its power supply automatically powers up again  
after three seconds, so long as the voltage has returned to  
its normal operating window. If the Acheron Designer does  
not power up after 10 seconds, remove AC power immedi-  
ately and contact Meyer Sound Technical Support.  
2. Voltage is detected and the power supply mode is auto-  
matically adjusted as necessary. The power supply  
ramps up.  
3. During the power up sequence, the three-color On/Sta-  
tus LED flashes all three colors.  
4. After the power up sequence and system check have  
completed, the ON/Status LED turns solid green, indicat-  
ing the loudspeaker is ready to reproduce audio.  
CAUTION: The power source for the  
Acheron Designer should always operate  
!
within the required voltage range, at least a few volts  
from the upper and lower ranges. This ensures that  
AC voltage variations from the service entry — or  
peak voltage drops due to cable runs — will not  
cause the loudspeaker’s amplifier to cycle on and off  
or cause damage to the power supply.  
CAUTION: If the On/Status LED does not turn  
green, or the Acheron Designer does not out-  
put audio after ten seconds, remove AC power imme-  
diately and verify that the voltage is within the  
required range. If the problem persists, contact  
Meyer Sound Technical Support.  
!
NOTE: When voltage fluctuates within the  
Acheron Designer’s operating range, automatic  
tap selection stabilizes the operating voltage. This  
tap selection is instantaneous with no audible arti-  
facts.  
ACHERON DESIGNER CURRENT  
REQUIREMENTS  
The Acheron Designer current draw is dynamic and fluctu-  
ates as operating levels change. Since different cables and  
circuit breakers heat up at varying rates, it is important to  
understand the following types of current ratings and how  
they affect circuit breaker and cable specifications.  
TIP: Since the Acheron Designer does not  
require a dedicated neutral line, and it can toler-  
ate elevated voltages from the ground line, it can be  
connected to line-line terminals in 120 V, 3-phase  
Wye systems. This results in 208 V AC between lines  
(nominal) and therefore draws less current than when  
using 120 V AC (line-neutral). Make sure that the volt-  
age remains within the Acheron Designer’s recom-  
mended operating window (100-264 V AC). The  
ground line must always be used for safety reasons  
and the line-to-ground voltage should never exceed  
264 V AC (typically 120 V AC from line-to-ground).  
Idle Current — The maximum rms current during idle  
periods.  
Maximum Long-Term Continuous Current — The  
maximum rms current during a period of at least 10 sec-  
onds. The Maximum Long-Term Continuous Current is  
used to calculate temperature increases for cables, to  
ensure that cable sizes and gauges conform to electrical  
code standards. The current rating is also used as a rat-  
ing for slow-reacting thermal breakers.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 2: POWER REQUIREMENTS  
Burst Current — The maximum rms current during a  
period of around one second. The Burst Current is used  
as a rating for magnetic breakers. It is also used for cal-  
culating the peak voltage drop in long AC cable runs  
according to the following formula:  
ELECTRICAL SAFETY GUIDELINES  
Pay close attention to these important electrical and safety  
guidelines.  
The Acheron Designer requires a grounded outlet.  
Always use a grounded outlet and plug.  
V pk (drop) = I pk x R (cable total)  
The Burst Current can also be used to calculate the AC  
looping capability of Acheron Designer.  
Ultimate Short-Term Peak Current — A rating for fast-  
reacting magnetic breakers.  
Inrush Current — The spike of initial current encoun-  
tered when powering on.  
gauges and circuit breaker ratings for the system’s operat-  
ing voltage.  
Do not use a ground-lifting adapter or cut the AC cable  
ground pin.  
Table 2: Acheron Designer Current Draw  
Current Draw  
115 V AC  
0.23 A rms  
1.58 A rms  
230 V AC  
0.19 A rms  
0.83 A rms  
100 V AC  
0.24 A rms  
1.78 A rms  
Idle Current  
Maximum Long-Term  
Continuous Current  
Earth ground  
Burst Current  
3.1 A rms  
1.4 A rms  
3.6 A rms  
Ultimate Short-Term  
Peak Current  
12.0 A peak  
8.0 A peak  
12.4 A peak  
Inrush Current  
25 A peak  
54 A peak  
20 A peak  
Chassis ground  
The minimum electrical service amperage required by an  
Acheron Designer loudspeaker system is the sum of the  
Maximum Long-Term Continuous Current for each loud-  
speaker. An additional 30 percent above the minimum  
amperage is recommended to prevent peak voltage drops at  
the service entry.  
Do not exceed the current capability of the 20-amp AC  
Input connector for the loudspeaker. When looping loud-  
speakers, consider the total current draw for all loud-  
speakers on the circuit, including the first loudspeaker.  
NOTE: For best performance, the AC cable  
voltage drop should not exceed 10 V, or  
10 percent at 115 V and 5 percent at 230 V. Make  
sure that even with AC voltage drops that the AC  
voltage always remains within the operating win-  
dows.  
Make sure the AC power cable for the loudspeaker has  
the appropriate power plug (on the other end) for the  
area in which you will operate the loudspeaker. In addi-  
tion, the AC power cable must be rated for the total cur-  
rent draw of all loudspeakers looped from the power  
source.  
Do not operate the unit if its power cable is frayed or bro-  
ken.  
Keep all liquids away from the Acheron Designer to avoid  
hazards from electrical shock.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3: AMPLIFICATION AND AUDIO  
The Acheron Designer’s low- and high-frequency drivers are  
AUDIO CONNECTORS  
powered by an extremely efficient onboard two-channel,  
Class-D amplifier that uses minimal AC power when idle.  
Internal signal processing includes a complex crossover, fre-  
quency and phase correction, and limiters that prevent  
driver overexcursion and regulate voice coil temperatures,  
ensuring maximum driver lifespan.  
The Acheron Designer includes female XLR Input and male  
XLR Loop output connectors.  
Input  
Limit  
Loop  
Looping Audio Input  
10k Balanced  
2
3
1
Input  
Limit  
Loop  
Looping Audio Input  
10k Balanced  
On / Status  
GND Circuit  
1k  
2
3
1
AVIS  
RISQUE DE CHOC  
ELECTRIQUE  
Earth/Chassis  
NE PAS OUVRIR  
On / Status  
GND Circuit  
1k  
CAUTION  
RISK OF  
ELECTRIC SHOCK  
DO NOT OPEN  
Acheron Designer Audio Connectors, Input and Loop Output  
Earth/Chassis  
Input Connector  
NID: 001848623900  
RMS Network  
The female XLR Input connector accepts a balanced audio  
signal with an input impedance of 10 kOhm. The connector  
uses the following wiring:  
Remote Mute  
Disable Enable  
Identify  
RMS 4.0  
Firmware  
Wink  
Activity  
Pin 1 — 1 kOhm to chassis and earth ground (ESD  
clamped)  
DO NOT  
DISCONNECT  
UNDER LOAD  
COMMERCIAL  
AUDIO SYSTEM  
AC INPUT  
RATING  
AC LOOP  
OUTPUT  
3JKB  
Pin 2 — Signal (+)  
100-240V~  
50-60 Hz  
4A MAX  
100-240V~  
50-60 Hz  
8A MAX  
Class 1 Wiring  
Pin 3 — Signal (–)  
Made in USA with domestic and foreign parts  
www.meyersound.com  
Case — Earth (AC) ground and chassis  
Acheron Designer Rear Panel with Optional RMS Module  
Pins 2 and 3 carry the input as a differential signal. Pin 1 is  
connected to earth through a 1 kOhm, 1000 pF, 15 V  
clamped network. This circuitry provides virtual ground lift  
for audio frequencies while allowing unwanted signals to  
bleed to ground. Make sure to use standard, balanced XLR  
audio cables with all three pins connected on both ends.  
Telescopic grounding is not recommended, and shorting an  
input connector pin to the case may cause a ground loop,  
resulting in hum.  
The Acheron Designer rear panel includes a slot for the  
optional RMS module, used for connecting to the RMS  
TIP: If unwanted noise or hiss is produced by  
the loudspeaker, disconnect its input cable. If  
the noise stops, there is most likely nothing wrong  
with the loudspeaker. To locate the source of the  
noise, check the audio cable, source audio, and AC  
power.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3: AMPLIFICATION AND AUDIO  
Loop Output Connector  
LIMITING  
The male XLR Loop output connector allows multiple  
Acheron Designers to be looped from a single audio source.  
For applications that require multiple Acheron Designers,  
connect the Loop output of the first unit to the Input of the  
second, and so forth.  
When source levels for the Acheron Designer exceed opti-  
mum input levels for its drivers, limiting is engaged and is  
indicated by the two Limit LEDs on the rear panel. The bot-  
tom LED indicates limiting for the low-frequency channel.  
The top LED indicates limiting for the high-frequency chan-  
nel. When engaged, limiting not only protects the drivers,  
but also prevents signal peaks from causing excessive dis-  
tortion in the amplifier’s channels, thereby preserving head-  
room and maintaining smooth frequency responses at high  
levels. When source levels return to normal, below the lim-  
iter’s threshold, limiting ceases.  
NOTE: The order in which loudspeakers are  
connected when looping audio signals is unim-  
portant. The Loop connector is wired in parallel to the  
Input connector and transmits the unbuffered source  
signal even when the Acheron Designer is powered  
off.  
High-frequency limiter (top LED)  
Low-frequency limiter (bottom LED)  
To avoid distortion whenlooping multipleAcheron Designers,  
make sure the source device can drive the total load imped-  
ance of the looped loudspeakers. In addition, the source  
device must be capable of delivering approximately 20 dBV  
(10 V rms into 600 ohms) to yield the maximum peak SPL  
over the entire operating bandwidth of the loudspeakers.  
Most professional audio equipment can transmit these  
source levels.  
Input  
Limit  
AVIS  
RISQUE DE CHOC  
ELECTRIQUE  
NE PAS OUVRIR  
CAUTION  
On / Status  
RISK OF  
ELECTRIC SHOCK  
DO NOT OPEN  
To calculate the load impedance for the looped loudspeak-  
ers, divide 10 kOhms (the input impedance for a single  
Acheron Designer) by the number of looped loudspeakers.  
For example, the load impedance for 10 Acheron Designer  
loudspeakers is 1000 ohms (10 kOhms / 10). To drive this  
number of looped loudspeakers, the source device should  
have an output impedance of 100 ohms or less. This same  
rule applies when looping Acheron Designer loudspeakers  
with other self-powered Meyer Sound loudspeakers and  
subwoofers.  
Limit LEDs  
The Acheron Designer performs within its acoustical specifi-  
cations at normal temperatures when the Limit LEDs are  
unlit, or if the LEDs are lit for two seconds or less and then  
turn off for at least one second. If an LED remains lit for lon-  
ger than three seconds, the loudspeaker enters hard limiting  
where:  
Increases to the input level have no effect.  
NOTE: Most source devices are capable of  
driving loads no smaller than 10 times their  
output impedance.  
Distortion increases due to clipping and nonlinear driver  
operation.  
The drivers are subjected to excessive heat and excur-  
sion, which will compromise their life span and may  
eventually lead to damage over time.  
CAUTION: Make sure that all cabling for  
looped loudspeakers is wired correctly (Pin 1  
!
to Pin 1, Pin 2 to Pin 2, and so forth) to prevent the  
polarity from being reversed. If one or more loud-  
speakers in a system have reversed polarity, fre-  
quency response and coverage will be significantly  
degraded.  
NOTE: The Acheron Designer uses digital limit-  
ers that add no noise and have no effect on the  
signal when the limiters are not engaged and the  
Limit LEDs are not lit.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ACHERON DESIGNER OPERATING INSTRUCTIONS  
ON/STATUS LED  
Heat Sink Ventilation Requirements  
During normal operation, the Acheron Designer’s On/Status  
LED is green. If the loudspeaker’s internal temperature  
reaches 75° C (167° F), the LED turns solid yellow and the  
loudspeaker’s gain is reduced by 3 dB. Though the  
Acheron Designer will continue to operate normally with the  
lower gain, when the On/Status LED is yellow, this is an indi-  
cation that the loudspeaker is reaching its maximum heat  
dissipation and a reduction in SPL is recommended. When  
the loudspeaker’s internal temperature cools to 60° C  
(140° F), the amplifier returns to normal operation.  
When installing the Acheron Designer flush against walls, or  
when mounting them in soffits or baffle walls, make sure to  
allow plenty of ventilation above the loudspeaker.  
When installing the Acheron Designer in a soffit with the  
loudspeaker flush against the back of the soffit (see  
Figure 2), allow at least 6 inches above the loudspeaker  
for ventilation.  
CAUTION: If the loudspeaker’s internal tem-  
perature reaches 125° C (257° F), gain is  
!
reduced by 6 dB to avoid damage to the loud-  
speaker.  
TIP: When the Acheron Designer is connected  
to an RMS network, the RMS software provides  
additional feedback on the loudspeaker’s operating  
temperature. For more information, see Chapter 6,  
“RMS Remote Monitoring System.”  
6.00  
[152 mm]  
Amplifier Cooling System  
The Acheron Designer’s amplifier relies solely on natural  
convection for cooling from air flowing over its heat sink.  
The rear-mounted, recessed heat sink yields efficient cool-  
ing and allows the unit to be placed flat against walls, when  
necessary. The amplifier and heat sink keep temperatures  
low, even when the unit is used at high ambient tempera-  
tures, and when driven continuously at high output levels.  
CAUTION: The Acheron Designer’s heat sink  
can reach temperatures of up to 85° C (185° F)  
!
during extreme operation. Use extreme caution when  
approaching the rear of the loudspeaker.  
Figure 2: Acheron Designer Mounted in Soffit, Flush Against Back  
of Soffit with 6” of Ventilation Above Loudspeaker  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CHAPTER 3: AMPLIFICATION AND AUDIO  
When installing the Acheron Designer in a soffit with the  
loudspeaker 1 inch from the back of the soffit (see  
Figure 3), allow at least 3 inches above the loudspeaker  
for ventilation.  
When installing the Acheron Designer in a baffle wall with  
no opening in the front of the wall for ventilation (see  
speaker within the baffle wall.  
3.00  
[76 mm]  
1.00  
[25 mm]  
Figure 4: Acheron Designer Mounted in Baffle Wall with Open  
Ventilation Above Loudspeaker  
Figure 3: Acheron Designer Mounted in Soffit, 1” Behind and 3”  
Above Loudspeaker for Ventilation  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 4: RIGGING  
The yoke’s cradle can be pivoted to install the loudspeaker  
with downtilt or uptilt. A “C” or “G” hanging clamp and steel  
safety cable (not included) are required to suspend the yoke.  
Important Safety Considerations!  
When installing Meyer Sound loudspeakers and subwoof-  
ers, the following precautions should always be observed:  
All Meyer Sound products must be used in accordance  
with local, state, federal, and industry regulations. It is  
the owner’s and user’s responsibility to evaluate the reli-  
ability of any mounting and rigging method for their  
application. Mounting and rigging should only be carried  
out by experienced professionals.  
Use mounting and rigging hardware that has been rated  
to meet or exceed the weight being hung.  
Make sure to attach mounting hardware to the building's  
structural components (studs or joists), and not just to  
the wall surface. Verify that the building's structure and  
the anchors used for the installation will safely support  
the total weight of the mounted loudspeakers.  
Use mounting hardware appropriate for the surface  
where the loudspeaker will be installed.  
Make sure bolts and eyebolts are tightened securely.  
Meyer Sound recommends using Loctite® on eyebolt  
threads and safety cables.  
Inspect mounting and rigging hardware regularly. Imme-  
diately replace any worn or damaged components.  
MYA-DES CRADLE-STYLE YOKE  
The Acheron Designer includes M6 threaded attachment  
points on the cabinet bottom for the optional MYA-DES cra-  
dle-style yoke, allowing the unit to be suspended from a sin-  
gle hanging point.  
MYA-DES Cradle-Style Yoke, Bottom View  
CAUTION: The MYA-DES mounting yoke is  
!
rated for a maximum downtilt of 45 degrees.  
NOTE: The top bar of the MYA-DES yoke  
accommodates hanging clamps with standard  
1/2- inch or 12 mm bolts.  
NOTE: For Acheron Designer dimensions and  
weight with the MYA-DES yoke, refer to  
M6 threaded  
attachment  
points  
Acheron Designer Cabinet Bottom, M6 Threaded Attachment Points  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 4: RIGGING  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 5: RMS REMOTE MONITORING SYSTEM  
The Acheron Designer is optionally available with the RMS  
remote monitoring system module, allowing it to be con-  
RMS SOFTWARE  
The optional RMS software provides extensive system sta-  
nected to an RMS network. RMS allows real-time monitor-  
ing of multiple Meyer Sound self-powered loudspeakers  
from a Windows-based computer. The RMS host computer  
communicates with Meyer Sound loudspeakers (equipped  
with RMS modules) via a simple twisted pair network, or an  
Ethernet network using an FT-10 to Ethernet adapter.  
tus and performance data for each loudspeaker, including  
amplifier voltage, limiting activity, power output, driver sta-  
tus, as well as mute and solo capability. Loudspeakers are  
added to the RMS network and assigned a node name dur-  
ing a one-time commissioning procedure where the loud-  
speaker is identified by either entering its unique Neuron ID,  
or by pressing its Identify button.  
NOTE: For the latest RMS system require-  
ments, visit www.meyersound.com.  
NOTE: The RMS software allows you to dis-  
able Mute and Solo functions to eliminate any  
possibility of accidentally muting loudspeakers. Mute  
and solo capability can also be disabled by removing  
the Mute Jumper from RMS modules. For more infor-  
mation, refer to the RMS User Guide.  
NOTE: RMS does not control AC power.  
RMS Add Loudspeaker Dialog Box  
Once loudspeakers are identified on the RMS network, they  
appear in the RMS software as icons and views; they are  
also automatically added to the RMS database on the host  
computer.  
Acheron Designer RMS Icons  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CHAPTER 5: RMS REMOTE MONITORING SYSTEM  
RMS software displays all loudspeakers on the network in a  
panel with icons, Meter views, and Text views that can be  
customized to suit your needs. Loudspeaker data is  
updated 2–5 times per second. Individual loudspeakers can  
be physically identified with the Wink option in RMS, which  
lights the Wink LED on the RMS module for that particular  
loudspeaker. Conversely, a loudspeaker can be identified in  
the RMS software by pressing the Identify button on the  
loudspeaker’s RMS module.  
RMS MODULE  
The Acheron Designer RMS module includes an Identify  
button, Wink/Activity LED, Remote Mute switch, and two  
Network connectors.  
Figure 5: Acheron Designer RMS Module  
NOTE: The buttons and LED on the  
Acheron Designer RMS module are used  
exclusively by RMS and have no effect on the acous-  
tical or electrical activity of the loudspeaker.  
Identify Button  
The Identify button serves the following functions:  
If the loudspeaker has not yet been commissioned  
(Wink/Activity LED not lit), press the Identify button to  
identify the loudspeaker on the RMS network and com-  
mission it.  
RMS Panel with Icons  
Loudspeaker icons and views can be arranged to represent  
how loudspeakers have been deployed in the system. Multi-  
ple panels can be saved and recalled for specific perfor-  
mances and venues.  
To decommission the loudspeaker, press and hold the  
To wink a commissioned loudspeaker, press the Identify  
button. The Wink LED on the loudspeaker icon in the  
RMS software lights up and the Wink/Activity LED on the  
loudspeaker’s RMS user panel turns solid green. Press  
the Identify button again to unwink the loudspeaker.  
NOTE: When the Acheron Designer heat sink  
reaches 85° C (185° F), the On/Status LED  
turns red, while its loudspeaker icon in the RMS soft-  
ware turns yellow — indicating the loudspeaker is  
running hot, but still within safe operating limits.  
Make sure that the loudspeaker is properly ventilated.  
TIP: The Wink function is useful for identifying  
the physical loudspeaker corresponding to a  
loudspeaker icon in the RMS software.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
ACHERON DESIGNER OPERATING INSTRUCTIONS  
Wink/Activity LED (Green)  
RMS Network Connectors  
The green Wink/Activity LED indicates the status of the  
loudspeaker:  
The two Weidmuller connectors transfer data to and from  
the RMS network. Two connectors are provided to allow for  
easy connection of multiple (daisy-chained) loudspeakers  
on the network. Included with each RMS-equipped loud-  
speaker are RMS cable connectors and mounting blocks for  
constructing RMS cables. The RMS blocks allow the cables  
to be securely attached to the RMS module with screws.  
During startup, the LED blinks 10 times.  
If the loudspeaker has not yet been commissioned, the  
LED is not lit after startup.  
If the loudspeaker has been successfully commissioned,  
the LED flashes continuously and flashes more rapidly  
with increased data activity.  
NEURON ID FOR THE RMS MODULE  
When the loudspeaker is winked, either by clicking the  
Wink button in the RMS software or by pressing the  
Identify button on the RMS user panel, the LED is solid  
green.  
Each Acheron Designer RMS module has a unique 12-char-  
acter Neuron ID (NID) that identifies the loudspeaker on the  
network. When commissioning the loudspeaker, the NID  
must either by entered manually or retrieved from the loud-  
speaker by pressing its Identify button. The NID for the RMS  
module is located on the user panel above the orange RMS  
TIP: The Wink function is useful for identifying  
the physical loudspeaker corresponding to a  
loudspeaker icon in the RMS software.  
RESETTING THE RMS MODULE  
Remote Mute Switch  
You can use the Identify button to reset the Acheron Designer  
RMS module when powering up the loudspeaker. This will  
cause the module to be decommissioned from the network.  
The recessed Remote Mute switch on the Acheron Designer  
RMS module determines whether the RMS software can  
control muting and soloing of the loudspeaker. The  
Acheron Designer ships from the factory with the switch  
enabled.  
To reset the Acheron Designer RMS module:  
1. Disconnect the loudspeaker’s power cord.  
2. Press and hold the Identify button.  
3. While continuing to hold down the Identify button, recon-  
nect the power cord.  
4. After the Wink/Activity LED blinks on and off, release the  
Identify button. The RMS module is reset and the loud-  
speaker is decommissioned.  
Remote Mute Switch  
Disable: When the Remote Mute switch is set to Disable  
(to the left), the loudspeaker cannot be muted and  
soloed from the RMS software.  
Enable: When the Remote Mute switch is set to Enable  
(to the right), the loudspeaker can be muted and soloed  
from the RMS software.  
NOTE: The RMS software also allows you to  
disable Mute and Solo functions to eliminate  
any possibility of accidentally muting loudspeakers.  
For more information, refer to the RMS User Guide.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 5: RMS REMOTE MONITORING SYSTEM  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 6: SYSTEM DESIGN AND INTEGRATION TOOLS  
Meyer Sound offers two comprehensive tools to assist with  
the acoustical and functional requirements of system design  
and optimization. This chapter introduces MAPP Online  
Cinema, Meyer Sound’s patented online acoustical predic-  
tion tool, and SIM 3, a comprehensive system for measure-  
ment and analysis.  
The key to the accuracy of MAPP Online Cinema’s predic-  
tions is its exhaustive database of Meyer Sound loud-  
speaker measurements. Performance predictions for each  
loudspeaker are based on 360 1/48th-octave-band mea-  
surements taken with a SIM audio analyzer in the Meyer  
Sound anechoic chamber. The extraordinary consistency  
between Meyer Sound loudspeakers guarantees that pre-  
dictions from MAPP Online Cinema will closely match their  
actual performance.  
MAPP ONLINE CINEMA  
MAPP Online Cinema is a powerful, cross-platform, Java-  
based application for accurately predicting the coverage  
pattern, frequency response, impulse response, and maxi-  
mum SPL output of Meyer Sound cinema loudspeakers.  
MAPP Online Cinema predictions are requested by the client  
software and sent via the Internet to the high-speed Meyer  
Sound servers where high-resolution (magnitude and phase)  
polar data is processed with sophisticated acoustical pre-  
diction algorithms. The resulting predictions are then  
returned to and displayed on the local computer running the  
MAPP Online Cinema client software.  
Residing on your local computer, the MAPP Online Cinema  
client lets you configure Meyer Sound loudspeaker systems  
and define the environment in which they will operate,  
including air temperature, pressure, humidity, and even the  
location and composition of walls. CAD (DXF) files contain-  
ing detailed venue information can also be imported.  
TIP: Meyer Sound offers seminars and webinars  
on using MAPP Online Cinema. For more infor-  
mation, visit www.meyersound.com.  
MAPP Online Cinema Applications  
With MAPP Online Cinema, you can:  
Simulate different loudspeaker configurations to refine  
system design and zero-in on the best coverage for  
intended audience areas  
Simulate different screen types to evaluate their trans-  
parence and reflectivity  
Monitor loudspeaker interactions to locate destructive  
interferences so that loudspeakers can be re-aimed and  
repositioned as necessary  
Place microphones anywhere in the sound field and pre-  
dict their frequency response, impulse response, and  
sound pressure  
MAPP Online Cinema  
Sound system designers can use MAPP Online Cinema to  
accurately predict the appropriate loudspeaker deployment  
for each job, complete with coverage data, system delay  
and equalization settings, and detailed design illustrations.  
MAPP Online Cinema’s accurate, high-resolution predic-  
tions ensure that systems will perform as expected, thereby  
eliminating unexpected coverage problems and minimizing  
on-site adjustments.  
Determine delay settings for surround loudspeakers  
Try out virtual Galileo equalization to determine optimum  
real-world settings for the best system response  
Generate and export system images for client presenta-  
tions  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 6: SYSTEM DESIGN AND INTEGRATION TOOLS  
Using MAPP Online Cinema  
Source Independent Measurement Technique  
MAPP Online Cinema is compatible with the following oper-  
ating systems:  
The SIM 3 audio analyzer implements Meyer Sound’s source  
independent measurement technique, a dual-channel  
method that accommodates statistically unpredictable exci-  
tation signals. Any excitation signal within a desired fre-  
quency range can be used to obtain highly accurate  
measurements for acoustical or electronic systems. For  
example, concert halls and loudspeaker systems can be  
captured during a performance and used as a SIM 3 test  
signal, so you can:  
Windows  
Linux®  
Unix®  
Mac OS®  
For information on which operating system versions are  
supported, visit www.meyersound.com.  
View measurement data as amplitude versus time  
(impulse response) or amplitude and phase versus fre-  
quency (frequency response)  
Downloading and Installing MAPP Online Cinema  
Utilize a single-channel spectrum mode  
To use MAPP Online Cinema, you must register online at  
www.meyersound.com. After entering your registration  
information, an email will be sent to you with your user  
name, password, and the MAPP Online Cinema download  
location. On-screen instructions will guide you through the  
download and installation process.  
View frequency domain data within a logarithmic fre-  
quency axis  
Determine and internally compensate for propagation  
delays using the SIM 3 Delay Finder  
The MAPP Online Cinema client software is regularly  
upgraded to add support for the latest Meyer Sound loud-  
speakers, as well as to add feature enhancements. Most  
upgrades are downloaded automatically when logging on to  
a MAPP Online Cinema session. The MAPP Online Cinema  
database includes all Meyer Sound EXP screen channel  
loudspeakers, surround loudspeakers, subwoofers, and  
processors.  
SIM 3 Applications  
The SIM 3’s primary applications are testing and aligning  
loudspeaker systems, which entails:  
Measuring propagation delays between subsystems to  
determine appropriate polarities and delay times  
Measuring variations in frequency response caused by  
the acoustical environment and the placement and inter-  
action of loudspeakers to determine corrective equaliza-  
tion  
SIM 3 MEASUREMENT SYSTEM  
The SIM 3 audio analyzer is a high-resolution audio mea-  
surement system comprised of software, hardware, micro-  
phones, and accessory cables. The SIM 3 is optimized for  
measuring audio frequencies with resolutions up 1/48th of  
an octave, allowing you to apply precise corrections to bal-  
ance system response using frequency and phase domain  
information.  
Optimizing subwoofer integrations  
Optimizing loudspeaker arrays  
The SIM 3 is also versatile and accurate enough for the fol-  
lowing applications:  
Microphone calibration and equalization  
Transducer evaluation and correction  
Echo detection and analysis  
Vibration analysis  
Architectural acoustics  
Underwater acoustics  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
APPENDIX A: ACHERON DESIGNER SPECIFICATIONS  
ACOUSTICAL  
Operating Frequency Range  
37 Hz – 18 kHz  
Note: Recommended maximum operating frequency range. Response depends on loading  
conditions and room acoustics.  
Frequency Response  
38 Hz – 17 kHz 4 dB  
Note: Measured free field with 1/3 octave frequency resolution at 4 meters.  
Phase Response  
230 Hz to 17 kHz 30°  
Maximum Peak SPL  
130 dB  
Note: Measured free field with music referred to 1 meter.  
Dynamic Range  
Coverage  
>110 dB  
80° horizontal by 50° vertical  
Crossover  
680 Hz  
Note: At this frequency, both transducers produce equal sound pressure levels.  
TRANSDUCERS  
Low Frequency  
One 12” cone driver  
Nominal impedance: 2  
Voice coil size: 4”  
High Frequency  
One 4” compression driver  
Nominal impedance: 8   
Voice coil size: 4”  
Diaphragm size: 4”  
Exit size: 1.5”  
AUDIO INPUT  
Type  
Differential, electronically balanced  
Maximum Common Mode Range  
Connectors  
5 V DC, clamped to earth for voltage transient protection  
Female XLR input with male XLR loop output  
10 kdifferential between pins 2 and 3  
Input Impedance  
Wiring  
Pin 1: Chassis/earth through 1 k, 1000 pF, 15 V clamp network to provide virtual ground lift at  
audio frequencies  
Pin 2: Signal +  
Pin 3: Signal –  
Case: Earth ground and chassis  
DC Blocking  
CMRR  
Differential DC blocking up to the maximum common mode voltage  
>50 dB, typically 80 dB (50 Hz – 500 Hz)  
RF Filter  
Common mode: 425 kHz  
Differential mode: 142 kHz  
TIM Filter  
<80 kHz, integral to signal processing  
Nominal Input Sensitivity  
Input Level  
10 dBV (3.2 V rms, 4.5 V peak) continuous is typically the onset of limiting for noise and music  
Audio source must be capable of producing +20 dBV (10 V rms, 14 V peak) into 600to pro-  
duce the maximum peak SPL over the operating bandwidth of the loudspeaker  
AMPLIFIER  
Type  
Two-channel, Class-D  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
APPENDIX A: ACHERON DESIGNER SPECIFICATIONS  
Output Power  
Total Output  
700 W total (550 W low channel, 250 W high channel)  
Note: Amplifier wattage rating based on the maximum unclipped burst sine-wave RMS volt-  
age the amplifier will produce into the nominal load impedance: low-frequency channel, 33 V  
rms into 2 ; high-frequency channel, 33 V rms into 8 .  
1400 W peak  
Note: Peak power output based on the maximum unclipped peak voltage the amplifier will  
produce into the nominal load impedance: low-frequency channel, 46 V peak into 2 ; high-  
frequency channel, 46 V peak into 8 .  
THD, IM TIM  
Load Capacity  
Cooling  
<.02%  
2 low channel, 8 high channel  
Convection, with recessed heat sink  
AC POWER  
Connectors  
Voltage Selection  
PowerCon with loop output  
Automatic, continuous range from 90–265 V AC  
100–240 V AC, 50/60 Hz  
Safety Agency Rated Operating Volt-  
age  
Turn On/Turn Off Points  
Current Draw  
90 V AC on, no turn-off, only fuse-protect above 265 V AC  
Idle Current  
0.23 A rms (115 V AC); 0.19 A rms (230 V AC); 0.24 A rms (100 V AC)  
1.58 A rms (115 V AC); 0.83 A rms (230 V AC); 1.78 A rms (100 V AC)  
Maximum Long-Term Continuous  
Current  
Burst Current  
3.1 A peak (115 V AC); 1.4 A peak (230 V AC); 3.6 A peak (100 V AC)  
Note: AC power cabling must be of sufficient gauge so that under burst current rms condi-  
tions, cable transmission losses do not drop below the loudspeaker’s specified operating volt-  
age range.  
Ultimate Short-Term Peak Current  
Inrush Current  
12.0 A peak (115 V AC); 8.0 A peak (230 V AC); 12.4 A peak (100 V AC)  
25 A peak (115 V AC); 54 A peak (230 V AC); 20 A peak (100 V AC)  
PHYSICAL  
Enclosure  
Premium birch plywood  
Low gloss, black textured  
Finish  
Protective Grille (Optional)  
Attachment points on cabinet front corners for optional grille frame with black cloth  
Note: Weight for grille frame is 2.0 lbs ((0.9 kg).  
Rigging (Optional)  
Two threaded M6 attachment points on cabinet bottom for optional MYA-DES cradle-style  
yoke  
Note: Weight for MYA-DES is 28.5 lbs (12.9 kg).  
Dimensions  
19.00" w x 25.38" h x 14.58" d (483 mm x 645 mm x 370 mm) without optional grille frame  
Weight 76.0 lbs (34.5 kg) without optional grille frame  
Weight  
ENVIRONMENTAL  
Operating Temperature  
Non Operating Temperature  
Humidity  
0° C to +45° C  
<–40° C or >+75° C  
to 95% at 35° C  
Operating Altitude  
Non Operating Altitude  
Shock  
to 4600 m (15,000 ft)  
to 95% at 35° C  
30 g 11 msec half-sine on each of 6 sides  
10 Hz – 55 Hz (0.010 m peak-to-peak excursion)  
Vibration  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACHERON DESIGNER OPERATING INSTRUCTIONS  
ACHERON DESIGNER COMPLIANCE  
ACHERON DESIGNER DIMENSIONS  
14.96  
[380 mm]  
6.96  
[177 mm]  
6.00  
[152 mm]  
19.00  
[483 mm]  
12.18  
[309 mm]  
25.00  
[635 mm]  
25.38  
[645 mm]  
14.00  
[356 mm]  
13.25  
[337 mm]  
12.25  
[311 mm]  
14.58  
[370 mm]  
3.51  
[89 mm]  
11.60  
[295 mm]  
5.25  
[133 mm]  
Acheron Designer  
Weight  
Without Grille Frame  
With Grille Frame  
76.0 lbs (34.5 kg)  
78.0 lbs (35.4 kg)  
Acheron Designer Dimensions  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX A: ACHERON DESIGNER SPECIFICATIONS  
ø0.56  
[ø14 mm]  
14.96  
[380 mm]  
2.00  
[51 mm]  
19.00  
[483 mm]  
24.13  
[613 mm]  
6.96  
[177 mm]  
12.18  
[309 mm]  
29.82  
[757 mm]  
25.38  
[645 mm]  
27.62  
[702 mm]  
22.00  
[559 mm]  
9.00  
[229 mm]  
5.25  
[133 mm]  
Acheron Designer  
3.00  
[76 mm]  
Weight  
Without MYA-DES Yoke  
With MYA-DES Yoke  
76.0 lbs (34.5 kg)  
104.5 lbs (47.4 kg)  
Acheron Designer Dimensions with MYA-DES Cradle-Style Yoke  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Meyer Sound Laboratories Inc.  
2832 San Pablo Avenue  
Berkeley, CA 94702  
© 2012  
Meyer Sound. All rights reserved.  
Acheron Designer Operating Instructions, PN 05.211.005.01 A  
T: +1 510 486.1166  
F: +1 510 486.835  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Kyocera All in One Printer 9530DN User Manual
Life Fitness Stepper Machine 90 Series User Manual
Lincoln Electric Welding Consumables IM10018 A User Manual
Linear Stereo Amplifier COMP DA 1X3 User Manual
Link electronic Switch IEC 754 User Manual
Logitech Mouse 1100R User Manual
Lowrance electronic GPS Receiver LCX 15 MT User Manual
Melissa Fan 271 018 User Manual
Meridian America Speaker System M3100 User Manual
Metra Electronics eBook Reader 99 5720 User Manual