Radio Frequency Bar Code Reader
Configuration Guide
Metrologic Instruments GmbH
Dornierstrasse 2
82178 Puchheim
GERMANY
Tel. : +49 (0) 89 890 19 0
Fax : +49 (0) 89 890 19 200
Download from Www.Somanuals.com. All Manuals Search And Download.
Metrologic Instruments GmbH makes no guaranteed declaration or offer concerning the contents
or use of this manual, and notably refutes any express or implicit liability as regards the
merchandisable quality or suitability for a particular use of the product.
In addition, Metrologic Instruments GmbH reserves the right to update this publication and to
make changes at any time without notice.
Metrologic Instruments GmbH refutes any liability concerning any modifications that might be
made to the commodities supplied.
You use this equipment at your own risks and perils.
Metrologic Instruments GmbH will not be held liable for any direct or indirect losses or damage
resulting from its use.
Moreover, Metrologic Instruments GmbH reserves the right to modify its products, entirely or in
part, at any time without notice.
This hardware is guaranteed by Metrologic Instruments GmbH for one year from the date of
delivery. During this period, any defective equipment item will be repaired or replaced without
charge.
Copyright 2001 Metrologic Instruments GmbH. All rights reserved.
This manual is intended for the private use of the recipient, whether supplied on paper or in
electronic form.
It may not be modified or copied by any means whatsoever without written authorization from
Metrologic Instruments GmbH.
All names of products mentioned in this documentation are registered trademarks of their
respective manufacturers.
MLPN XX-XXXXX
January 2002
i
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Metrologic Instruments GmbH
Donierstrasse 2
82178 Puchheim
GERMANY
Tel.:+49 (0)89 890 190
Fax:+49 (0)89 890 19 200
Metrologic Instruments Italia S.r.L.
Via Emilia 70
40064 Ozzano Dell'Emilia (BO)
ITALY
Tel.:+39 051 651 19 78
Fax:+39 051 652 13 37
Metrologic Eria Ibérica S.A.
Julian Camarillo 29, D1 Bajo
28037 Madrid
SPAIN
Tel.:+34 91 327 24 00
Fax:+34 91 327 38 29
Metrologic Eria Ibérica S.A.
Consell de Cent 106 – 108 – 3° 3a
08015 Barcelona
SPAIN
Tel.:+34 93 423 11 10
Fax:+34 93 423 14 76
Metrologic Eria France S.A.
Z.I. Paris Nord II, 69, rue de la Belle Etoile, Bât. E – B.P. 50057
95947 Roissy CDG Cedex
FRANCE
Tel.:+33 (0)1 48 63 78 78
Fax:+33 (0)1 48 63 24 94
Metrologic Instruments U.K., Ltd.
58 Tempus Business Centre, Kingsclere Road
Basingstoke, Hampshire RG21 6XG
UNITED KINGDOM
Tel.:+44 (0) 1256 365 900 Fax:+44 (0) 1256 365 955
ii
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
1.
2.
INTRODUCTION.............................................................................................................1
1.1. Default Configuration (factory setting)..............................................................3
COMMUNICATION MODES...........................................................................................5
2.1. RS232....................................................................................................................6
2.1.1. Baud Rate..................................................................................................6
2.1.2. Data Bits ....................................................................................................7
2.1.3. Parity..........................................................................................................7
2.1.4. Stop Bits ....................................................................................................7
2.1.5. End of Message Character........................................................................8
2.1.6. Time-Out Between Characters ..................................................................9
2.1.7. ACK/NAK Protocol...................................................................................10
2.1.8. XON/XOFF Protocol ................................................................................10
2.1.9. RTS/CTS Protocol ...................................................................................10
2.1.10. PC-Term Mode ........................................................................................11
2.2. Keyboard-Wedge ...............................................................................................12
2.2.1. End of Message Character......................................................................14
2.2.2. Upper / Lower Case Options ...................................................................14
2.2.3. Types of Numeric Characters..................................................................15
2.2.4. Time-Out Between Characters ................................................................15
2.2.5. "WYSE" Time-Out....................................................................................16
2.3. P.O.S. (Point Of Sale) Systems.........................................................................17
2.4. Wand Emulation.................................................................................................18
2.4.1. Transmission Speed................................................................................18
2.4.2. Bar/Space Polarity...................................................................................19
2.4.3. Idle State..................................................................................................19
2.5. Laser Emulation.................................................................................................20
SYMBOLOGIES ...........................................................................................................21
3.
3.1. Symbology Selection ........................................................................................22
3.2. Code 39...............................................................................................................24
3.2.1. Standard/Full ASCII.................................................................................24
3.2.2. Full ASCII Extended ................................................................................24
3.2.3. Multiread..................................................................................................25
3.2.4. Modulo 43 Check Character....................................................................25
3.2.5. Pharmacode or Pharma 32/39.................................................................26
3.2.6. CIP Code 39 ............................................................................................26
3.2.7. Start/Stop.................................................................................................27
3.2.8. Modulo 43 Algorithm................................................................................27
3.3. Interleaved 2/5....................................................................................................28
3.3.1. Fixed Length(s) Authorized and Set Upon First Reading(s)....................28
3.3.2. Fixed Length(s) Authorized and Set Using the Numeric Pad ..................29
3.3.3. Variable Lengths Authorized....................................................................30
3.4. UPC/EAN.............................................................................................................31
iii
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.4.1. Types of UPC/EAN Authorized................................................................31
3.4.2. Transformations.......................................................................................31
3.4.3. Add-On Options.......................................................................................32
3.4.4. Leading Prefixes for P.O.S. Systems ......................................................33
3.4.5. Flag Option ..............................................................................................33
3.4.6. Check Digit Options.................................................................................34
3.4.7. Product Code...........................................................................................34
3.4.8. ISBN Conversion .....................................................................................34
3.5. Monarch/Codabar ..............................................................................................35
3.5.1. Start/Stop.................................................................................................35
3.5.2. Concatenation..........................................................................................35
3.6. Code 128.............................................................................................................36
3.6.1. Check Character......................................................................................36
3.6.2. FNC2 Function.........................................................................................36
3.7. UCC/EAN 128 .....................................................................................................37
3.8. Standard 2/5 .......................................................................................................38
3.8.1. Number of Lengths Authorized................................................................38
3.8.2. Start/Stop Types......................................................................................38
3.9. MSI ......................................................................................................................39
3.9.1. Variable or Fix Lengths............................................................................39
3.9.2. Double Check Digit (Modulo 10)..............................................................39
3.9.3. Single Check Digit (Modulo 10) ...............................................................39
3.10. Plessey ...............................................................................................................40
3.11. Telepen ...............................................................................................................40
3.12. Code 93...............................................................................................................40
3.13. Matrix 2/5 ............................................................................................................41
3.13.1. Types of Start/Stop..................................................................................41
3.13.2. Check Digit ..............................................................................................41
3.13.3. Fixed or Variable Lengths........................................................................41
3.13.4. Setting the Authorized Lengths................................................................42
3.14. IATA ....................................................................................................................43
3.15. BC 412.................................................................................................................43
3.16. 3W7 .....................................................................................................................43
3.17. Leading Identifiers.............................................................................................44
3.17.1. Identifier with One Character...................................................................44
3.17.2. Identifier with Three Characters...............................................................44
3.18. Decoding Selectivity..........................................................................................45
OPERATING MODES...................................................................................................47
4.
4.1. Simple Acknowledgment ..................................................................................47
4.2. Host System Acknowledgment ........................................................................48
4.3. On File / Not On File ..........................................................................................48
4.3.1. Setting the On File Character ..................................................................49
4.3.2. Setting the Not On File Character............................................................49
4.4. Bell ......................................................................................................................50
iv
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4.5. Setting the Timers .............................................................................................51
4.5.1. Timer T1 ..................................................................................................51
4.5.2. Timer T2 ..................................................................................................52
4.5.3. Timer T3 ..................................................................................................52
5.
6.
EDITING MODE............................................................................................................53
APPENDIXES...............................................................................................................55
6.1. Radio Parameters ..............................................................................................55
6.1.1. Radio Channel.........................................................................................55
6.1.2. Number of Re-transmissions ...................................................................56
6.2. Adjustment of the Beep Sound ........................................................................57
6.2.1. Laser Reader...........................................................................................57
6.2.2. Radio Base ..............................................................................................57
6.3. Preamble / Postamble .......................................................................................58
6.3.1. Preamble Character.................................................................................58
6.3.2. Postamble Character...............................................................................58
6.3.3. Clear Buffer..............................................................................................58
6.4. Conversion of Characters.................................................................................59
6.4.1. First Character.........................................................................................59
6.4.2. Second Character....................................................................................61
6.5. Rolling Buffer Mode...........................................................................................62
6.6. Transmission of the Full ASCII Character Set ................................................63
6.7. Displaying the Firmware Level.........................................................................64
6.8. Code 39 Full ASCII Extended Table .................................................................65
6.9. Multiread character Table .................................................................................67
6.10. Code 39 Full ASCII Table ..................................................................................70
6.11. Numeric Pad.......................................................................................................81
6.12. Samples of Bar Codes.......................................................................................82
v
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Page intentionally left blank
vi
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
1.
INTRODUCTION
This manual contains information about configuration IS1000 laser reader and decoder present
in the radio base.
The installation procedures and technical description are described in the IS1000 Installation
and User’s Guide.
The IS1000 Connection List contains the connection numbers (or ID) and the cable references
to be used for Keyboard-Wedge communication on PCs and terminals, for communication with
P.O.S. systems and Notebooks. For other types of connections see chapter 2, Communication
Modes.
1
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Once the radio base is powered on, each parameter value can be changed simply by scanning,
with the laser reader, the codes appearing in this manual with respect to configuration sequence.
START OF CONFIGURATION
bottom left of each page
Chapter 2
Page 5
COMMUNICATION MODES
Selection of the communication mode and adjustment of the transmission parameters
Chapter 3
Chapter 4
Chapter 5
Chapter 6
Page 21
Page 47
Page 53
Page 55
SYMBOLOGIES
Selection and adjustment of options
OPERATING MODES
Selection of the operating mode and adjustment of options
EDITING MODE
Adjustment of data formats
APPENDIXES
Adjustment of data formats
END OF CONFIGURATION
bottom right of each page
! Note:
There is no need to adjust all the parameters. Change only the ones concerning your application.
Unchanged parameters will keep their previous value.
The parameter values are stored in a non-volatile memory called EEPROM and are saved when
the radio base is turned off.
2
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
1.1. Default Configuration (factory setting)
When shipped from the factory, each IS1000 is configured with default parameter values
as follows:
Default Configuration
RS232 mode:
- 9600 bps
- Even parity
- 7 data bits
Communication Mode
- 1 stop bit
- CR/LF end of message characters
Code 39, Code 128, EAN 128, UPC/EAN, Interleaved 2/5,
Monarch/Codabar
Symbology
Radio
433 MHz – Channel 3
- Simple acknowledgment mode
- Timer 1 = 200 ms
Operating Mode
Buzzer
- Timer 2 = 3 s
- Timer 3 = 2 s
- Number of re-transmissions = 3
High volume
These are the main parameters, please check the sections of this manual which concern
your application.
The default value of each parameter appears like this:
3 to 5 characters
Code 39
FUNCTION X ACTIVATED *
The text below the code is framed and ended by the sign * to indicate the default value.
At any time, the default values of all the parameters can be set by scanning this code:
DEFAULT CONFIGURATION
! Caution:
The reading of this code will turn all parameters to their default value.
3
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Page intentionally left blank
4
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.
COMMUNICATION MODES
The radio base is equipped with a decoder offering a multi-interface communication port.
The default communication mode is RS232 (9600 baud, 7 data bits, parity even, 1 stop bit, end
message: CR LF).
Other communication modes can be selected by using the following sequence:
Read the code Start of Configuration
bottom left of each page
Select the mode of communication
Adjust the transmission parameters
Read the code End of Configuration
bottom right of each page
START OF CONFIGURATION
END OF CONFIGURATION
5
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1. RS232
Use the codes on this page through to page 11 to activate and adjust the RS232
parameters.
RS232 MODE ACTIVATED *
2.1.1. Baud Rate
300
600
1200
2400
4800
9600 *
19200
38400
START OF CONFIGURATION
END OF CONFIGURATION
6
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1.2. Data Bits
8
7 *
2.1.3. Parity
MARK
EVEN *
ODD
SPACE
2.1.4. Stop Bits
2
1 *
START OF CONFIGURATION
END OF CONFIGURATION
7
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1.5. End of Message Character
One character can be systematically transmitted with each code to indicate the
end of message:
STX…ETX
SUITE (MINITEL)
LF
CR/LF *
HT
NONE
CR
EOT
Other characters or complete fields can be added to the message using the
Preamble / Postamble function (see appendix 6.3, page 58) or the Editing Mode
(see chapter 5, page 53).
START OF CONFIGURATION
END OF CONFIGURATION
8
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1.6. Time-Out Between Characters
In case that errors are detected using high speed transmissions such as 19200 or
38400 baud and if two stop bits are already set, a time-out can be inserted
between each character for a better synchronization:
10 ms
0 ms *
20 ms
50 ms
100 ms
START OF CONFIGURATION
END OF CONFIGURATION
9
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1.7. ACK/NAK Protocol
Once this protocol is activated, the decoder waits for an acknowledgment from the
host system:
• ACK (06 hexa) means: message correctly received by the host system.
• NAK (15 hexa) means: message incorrectly received by the host, upon
reception of this character the decoder resends the
message.
ACK/NAK ACTIVATED
ACK/NAK DISACTIVATED *
2.1.8. XON/XOFF Protocol
Using this protocol, the host system can control the data flow coming from the
decoder:
• XON (11 hexa) means: host system ready to receive data.
• XOFF (13 hexa) means: host system busy, the decoder stops the transmission
and waits for an XON.
XON/XOFF ACTIVATED
XON/XOFF DISACTIVATED *
2.1.9. RTS/CTS Protocol
This protocol is a hardware "handshake" between the decoder and the host
system. Before transmitting data, the decoder rises its RTS signal (pin 4) to +10
volt and waits for a +10 volt signal on its CTS (pin 5) from the host. The rest
position of the two pins is -10 volt.
RTS/CTS PROTOCOL ACTIVATED
RTS/CTS PROTOCOL DISACTIVATED *
START OF CONFIGURATION
END OF CONFIGURATION
10
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1.10. PC-Term Mode
Some applications use several RS232 terminals connected to a PC host system
configured in PC-Term mode. When a character is typed on a keyboard of a
terminal, its scan code value is transmitted to the PC instead of its ASCII value.
Then, upon reception, the PC sends back the corresponding ASCII character to
display on the screen.
Therefore, once this mode is activated, the decoder sends the scan code value of
each character read.
To activate the PC-Term mode, read this code and adjust the RS232 parameters
using page 6 to 10. It is advised to insert a time-out of 50 ms between each
character when baud rate is over 9600 baud (see page 9).
PC-TERM MODE ACTIVATED
Upper/lower case characters and the type of numeric characters can be adjusted
using page 14 and 15.
Keyboard layout style can be selected using the Bar Code Pad page 12, without
reading the code Keyboard-Wedge Mode Activated.
START OF CONFIGURATION
END OF CONFIGURATION
11
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2. Keyboard-Wedge
In this mode the radio base is connected between the keyboard and the computer (or
terminal). Data is emulated by the decoder as if it was typed on the keyboard.
The default communication mode (factory setting) is RS232, use the codes on this page to
activate the Keyboard-Wedge mode and to select the ID corresponding to your computer
or terminal:
KEYBOARD-WEDGE MODE ACTIVATED
Consult the IS1000 Connection List and enter the ID
corresponding to your computer or terminal using this Bar Code Pad
0
2
4
6
8
1
3
5
7
9
START OF CONFIGURATION
END OF CONFIGURATION
12
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
PC Keyboard-Wedge ID:
PC Keyboard Type
ID
ALT Mode
Belgian
French
German
Hungarian
Italian
114
644
1
104
437
123
313
169
148
611
11
Spanish
Swedish
Swiss
UK
US
! Note:
For other Keyboard-Wedge interfaces, please refer to the IS1000 Connection List to obtain
ID and cable reference.
START OF CONFIGURATION
END OF CONFIGURATION
13
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2.1. End of Message Character
One of the characters below can be systematically emulated by the decoder as the
end of message character:
FIELD EXIT
RETURN *
ENTER
TAB +
CR/LF ; FEED ; SEND
LF
FIELD ADVANCE
NO CHARACTER
Other characters, signs, function keys or fields can be added using the Preamble /
Postamble function (see appendix 6.3, page 58) or the Editing Mode (see chapter
5, page 53).
2.2.2. Upper / Lower Case Options
Use one of these codes to inform the decoder of the state of your keyboard:
LOWER CASE/SMALL
UPPER CASE/CAPS *
START OF CONFIGURATION
END OF CONFIGURATION
14
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2.3. Types of Numeric Characters
This function allows the emulation of the numeric characters of the numeric pad or
those located on top of the keyboard.
Use this function if trouble occurs with upper/lower case keyboard modes.
NUMERIC PAD
NUMERICS LOCATED
OVER THE ALPHANUMERIC PAD *
! Note:
If the option Numeric Pad is chosen, the numeric pad of the keyboard must be
also turned on (or locked) for correct operation.
2.2.4. Time-Out Between Characters
The insertion of a time-out between each character can sometimes avoid eventual
errors due to a fast transmission speed (specially on PS/2 or when DOS and BIOS
are very busy).
5 ms
20 ms
100 ms
0 ms *
10 ms
50 ms
START OF CONFIGURATION
END OF CONFIGURATION
15
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2.5. "WYSE" Time-Out
Some Keyboard-Wedge connections on some Wyse terminals can drop
characters especially when a string of identical characters appears in a code.
Only in this case, use this function to insert a time-out between characters:
ACCESS CODE TIME-OUT
Enter the desired value
using the Numeric Pad page 81
0 ≤ value ≤ 49
VALIDATION
START OF CONFIGURATION
END OF CONFIGURATION
16
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3. P.O.S. (Point Of Sale) Systems
The main communication modes with P.O.S. systems are:
• RS232
• Keyboard-Wedge
• OCIA
• RS485
To set RS232 communication use pages 6 to 11 to adjust the transmission parameters.
To set a Keyboard-Wedge, OCIA or RS485 communication use page 12 of this manual;
scan the code Keyboard-Wedge Mode Activated and enter your ID.
! Note:
Please refer to the IS1000 Connection List to obtain ID and cable reference.
START OF CONFIGURATION
END OF CONFIGURATION
17
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.4. Wand Emulation
Scan this code to activate the wand emulation mode:
WAND EMULATION MODE ACTIVATED
Then select the symbology to be emulated using the Bar Code Pad page 12, without
reading the code Keyboard-Wedge Mode Activated:
Emulation
Code 39
ID
69
68
70
Interleaved 2/5
UPC/EAN *
* Only 8 or 13 characters messages are accepted for this emulation
Then adjust the following transmission parameters.
2.4.1. Transmission Speed
HIGH *
MEDIUM
LOW
START OF CONFIGURATION
END OF CONFIGURATION
18
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.4.2. Bar/Space Polarity
BAR = 0, SPACE = 1
BAR = 1, SPACE = 0 *
2.4.3. Idle State
LOW (0 VOLT)
HIGH (5 VOLT) *
START OF CONFIGURATION
END OF CONFIGURATION
19
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2.5. Laser Emulation
With this mode, data are transmitted as code 39 data coming from a TTL hand held laser
or CCD scanner.
Scan this code to activate this mode:
LASER EMULATION MODE ACTIVATED
! Note:
For the radio base connector pin-out, refer to the IS1000 Installation and User’s Guide.
START OF CONFIGURATION
END OF CONFIGURATION
20
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.
SYMBOLOGIES
Many bar code symbologies have been developed to suit many data capture applications in
different domains (retail, industry, medical, transport…) requiring simple or complete sets of
characters (numeric, alphanumeric, full ASCII set…) with various density performances.
Each symbology has options which must be carefully checked and adjusted by the user.
Some samples are printed in appendix 6.12, page 82.
The default configuration of the IS1000 permits the reading of only six bar code symbologies
appearing on the next left hand page.
Other symbologies can be selected on the next right hand page by using the following sequence:
Read the code Start of Configuration
bottom left of each page
Read the code New Selection
Select the new group of bar code
symbologies desired
Adjust the options of each bar code
symbology desired
Read the code End of Configuration
bottom right of each page
To fully optimize the decoding reliability, it is advised to select only the symbology(ies) required
for your application.
In addition, a function called Decoding Selectivity (see page 45) will perform several data
collections and decodings with comparisons before transmission.
START OF CONFIGURATION
END OF CONFIGURATION
21
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1. Symbology Selection
NEW SELECTION
This code must be read to initialize
any new selection of symbologies
CODE 39 *
UPC/EAN *
CODE 128 *
INTERLEAVED 2/5 *
MONARCH/CODABAR *
EAN 128 *
These six bar code symbologies are the most commonly used and are active by default.
Other symbologies can be selected on the next page.
! Note:
• If no symbology is selected after the reading of New Selection code, the above six
symbologies will remain activated.
• Only the symbologies selected after the reading of New Selection code will be activated
• If New Selection code is not read before selecting another symbology, this will be added
to the six of above.
START OF CONFIGURATION
END OF CONFIGURATION
22
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
STANDARD 2/5
PLESSEY
CODE 93
IATA
MSI
TELEPEN
MATRIX 2/5
BC 412 **
3W7
Reserved # 1
Reserved # 2
Reserved # 3
Once your selection is completed, consult the next pages to verify and adjust the options
you require for each symbology.
** Strictly reserved for IBM and authorized companies; require a specific firmware.
START OF CONFIGURATION
END OF CONFIGURATION
23
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2. Code 39
This is the most popular alpha-numeric bar code symbology. It has a set of 43 characters
(alphanumeric and a few symbols) and can be used with or without a check digit.
3.2.1. Standard/Full ASCII
The Code 39 Full ASCII option allows the transmission of the 128 ASCII
characters. Each ASCII character is a combination of two Code 39 characters. It
can be very useful specially to transmit control characters (STX, ETX, TAB, EOT…)
as preambles or postambles in a message (see appendix 6.3, page 58). The Code
39 Full ASCII Table is listed in appendix 6.10, page 70.
FULL ASCII
STANDARD *
3.2.2. Full ASCII Extended
In Keyboard-Wedge mode, function keys like F1 to F12, t, HOME, CLEAR… can
be emulated using this function.
The function key to be emulated is represented by two Code 39 characters from
the Code 39 Full ASCII Extended Table (see appendix 6.8, page 65), which can
be part of the symbol or separate from it.
ACTIVE ON TWO CHARACTERS
PRECEDED BY A DASH
DISACTIVATED *
(part of or separate from the symbol)
ACTIVE ON TWO CHARACTERS
(part of or separate from the symbol)
ACTIVE ONLY ON TWO CHARACTERS
SEPARATE FROM THE SYMBOL
! Note:
The function key value to be emulated can be set as a preamble or a postamble of
message (see appendix 6.3, page 58).
START OF CONFIGURATION
END OF CONFIGURATION
24
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.3. Multiread
ACTIVATED
DISACTIVATED *
The Multiread function permits the temporary storage of one or more codes in the
decoder's memory which will then be transmitted in a single string message.
To operate the Multiread function, the desired group of codes to be first stored
must have a Multiread Character as the leading character. This character can be
chosen in the Multiread Character Table (see appendix 6.9, page 67; default is
SPACE character) after reading code Activated. The transmission will start once a
code having no Multiread Character is read.
3.2.4. Modulo 43 Check Character
In the case of high level security applications, a check character can be integrated
as the last character in the code and verified before transmission.
VERIFIED AND TRANSMITTED
NOT VERIFIED *
VERIFIED AND NOT TRANSMITTED
! Note:
See page 27 for the calculation algorithm of Code 39 Modulo 43 Check Character.
START OF CONFIGURATION
END OF CONFIGURATION
25
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.5. Pharmacode or Pharma 32/39
This symbology is used only in Italy. The encoding uses the Code 39 standard but
the decoding performs a transformation of the digits using a translation table.
Example:
The Code 39 message: 2 D W W K P will be transformed into 080638517.
To activate this symbology, the code New Selection must be read first.
PHARMACODE ACTIVATED
START/STOP TRANSMITTED
CHECK DIGIT NOT TRANSMITTED
NEW SELECTION *
START/STOP NOT TRANSMITTED *
CHECK DIGIT TRANSMITTED *
3.2.6. CIP Code 39
CIP Code is specific to the French pharmaceutical industry. This function allows
the reading of the CIP Code 39 only (code with 7 characters), with the possibility of
transmitting or not the check digit. To cancel this function, read the code All Codes
39.
ACTIVATED WITH
ACTIVATED WITH
CHECK DIGIT NOT TRANSMITTED
CHECK DIGIT TRANSMITTED
ALL CODES 39 *
START OF CONFIGURATION
END OF CONFIGURATION
26
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.7. Start/Stop
This function activates the transmission of the start and stop characters (sign ¸).
TRANSMITTED
NOT TRANSMITTED *
3.2.8. Modulo 43 Algorithm
Code 39 is strongly self checked and most situations do not require a check
character. If a specific application requires exceptional data security, a check
character can be added as the last character of the code.
Example:
Message: 12345/ABCDE
Sum of values: 1 + 2 + 3 + 4 + 5 + 40 + 10 + 11 + 12 + 13 + 14 = 115
Divide 115 by 43. The quotient is 2 with the remainder 29. The check character is
the character corresponding to the value of the remainder, which is 29 in this
example, corresponding to the character T.
The complete message, including check character is: 12345/ABCDET.
Numerical value assignments for computing the optional check character:
Character Value
Character Value
Character Value
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
0
1
F
G
H
I
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
U
30
31
32
33
34
35
36
37
38
39
40
41
42
V
2
W
3
X
4
J
Y
5
K
L
Z
6
-
7
M
N
O
P
Q
R
S
T
.
8
Space
9
$
/
10
11
12
13
14
+
%
START OF CONFIGURATION
END OF CONFIGURATION
27
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3. Interleaved 2/5
This symbology is only numeric and offers a very high density of characters per inch due to
its interleaved encoding system. The decoding is very easy even if the symbols are poorly
printed. These advantages make it very popular for industrial applications.
But to avoid missing characters when scanning is incomplete, it has to be used with fixed
lengths (see pages 28 or 29) or variable lengths with a check digit (see page 30).
3.3.1. Fixed Length(s) Authorized and Set Upon First Reading(s)
The characters are interleaved (always paired), therefore it is necessary to define
whether the number of significant characters is odd or even.
ODD
EVEN *
2 LENGTHS FIXED AFTER
THE FIRST 2 READS
1 LENGTH FIXED AFTER THE FIRST READ *
3 LENGTHS FIXED AFTER
THE FIRST 3 READS
4 LENGTHS FIXED AFTER
THE FIRST 4 READS
! Note:
In this mode, the code lengths are not saved after power-off.
START OF CONFIGURATION
END OF CONFIGURATION
28
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.2. Fixed Length(s) Authorized and Set Using the Numeric Pad
Select the number of code length(s) desired (1 to 4):
ONE
TWO
THREE
FOUR
Select the N° of the length to be adjusted:
LENGTH N° 1
LENGTH N° 2
LENGTH N° 3
LENGTH N° 4
Enter the desired number of characters
using the Numeric Pad page 81
VALIDATION
Go back to adjust a next N° of length or read the code End of Configuration if no
other lengths is desired.
! Note:
In this mode, the code lengths are saved after power-off.
START OF CONFIGURATION
END OF CONFIGURATION
29
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.3.3. Variable Lengths Authorized
ACTIVATED
CHECK DIGIT
CHECK DIGIT
VERIFIED AND TRANSMITTED
VERIFIED BUT NOT TRANSMITTED
How to calculate the check digit value:
Example:
Message: 14356
Add the odd positions: 1 + 3 + 6 = 10
Multiply by 3 = 30
Add the even positions. 30 + 4 + 5 = 39
The check digit is the complement to the next ten: CK = 40 – 39 = 1
The printed message will be: 143561
CIP CHECK DIGIT
CIP CHECK DIGIT
VERIFIED AND TRANSMITTED
VERIFIED BUT NOT TRANSMITTED
CHECK DIGIT NOT VERIFIED *
! Caution:
The mode Check Digit Not Verified is not advised, missing characters can occur in
case of incomplete scanning of a code.
START OF CONFIGURATION
END OF CONFIGURATION
30
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.4. UPC/EAN
This symbology is mainly used for retail applications. It has fixed lengths (8 or 12
characters for UPC, 8 or 13 characters for EAN) and uses a check digit as the last
character and is only numeric. Two or five supplemental digits called Add-On can be
added to the right hand size of the codes.
3.4.1. Types of UPC/EAN Authorized
ALL UPC/EAN CODES *
UPC A AUTHORIZED
EAN 13 AUTHORIZED
UPC E AUTHORIZED
EAN 8 AUTHORIZED
! Note:
Several selections can be accumulated.
3.4.2. Transformations
UPC TRANSMITTED AS UPC
UPC TRANSMITTED AS EAN *
UPC E TRANSMITTED AS UPC A
UPC E TRANSMITTED AS UPC E *
START OF CONFIGURATION
END OF CONFIGURATION
31
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.4.3. Add-On Options
The Add-On is a group of 2 or 5 digits printed on the right hand size of a code
which can be transmitted or not depending of the following settings:
ADD-ON TRANSMITTED
ADD-ON NOT TRANSMITTED *
If Add-On Transmitted is set, some conditions can be fixed:
ADD-ON MUST BE PRESENT
ADD-ON MAY NOT BE PRESENT *
If Add-On Must Be Present is selected, other conditions can be fixed:
On the type of Add-On accepted:
WITH 2 OR 5 CHARACTERS *
WITH 5 CHARACTERS ONLY
WITH 2 CHARACTERS ONLY
For specific applications with EAN 13 on magazines:
Code EAN 13 starting with the 3 digits 378 or 379 will be decoded only if the Add-
On is available and correctly decoded.
ACTIVATED
DISACTIVATED *
START OF CONFIGURATION
END OF CONFIGURATION
32
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.4.4. Leading Prefixes for P.O.S. Systems
Leading characters can be transmitted with each code to inform the P.O.S. system
with the type of UPC or EAN read.
The prefixes are: FF for EAN 8, F for EAN 13, A for UPC A, E for UPC E.
PREFIXES TRANSMITTED
PREFIXES NOT TRANSMITTED *
3.4.5. Flag Option
The Flag is the first digit of the code. It can be transmitted or suppressed.
EAN 13 FLAG NOT TRANSMITTED
EAN 8 FLAG NOT TRANSMITTED
UPC A FLAG NOT TRANSMITTED
UPC E FLAG NOT TRANSMITTED
EAN 13 FLAG TRANSMITTED *
EAN 8 FLAG TRANSMITTED *
UPC A FLAG TRANSMITTED *
UPC E FLAG TRANSMITTED *
START OF CONFIGURATION
END OF CONFIGURATION
33
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.4.6. Check Digit Options
EAN 13 CHECK DIGIT NOT TRANSMITTED
EAN 8 CHECK DIGIT NOT TRANSMITTED
UPC A CHECK DIGIT NOT TRANSMITTED
UPC E CHECK DIGIT NOT TRANSMITTED
EAN 13 CHECK DIGIT TRANSMITTED *
EAN 8 CHECK DIGIT TRANSMITTED *
UPC A CHECK DIGIT TRANSMITTED *
UPC E CHECK DIGIT TRANSMITTED *
3.4.7. Product Code
The product code is represented by the last six digits (without the check digit) can
be transmitted alone:
PRODUCT CODE ONLY
ALL CHARACTERS TRANSMITTED *
3.4.8. ISBN Conversion
This function converts UPC/EAN codes appearing on book into ISBN format.
The 3 leading digits and the check digit of UPC/EAN codes are suppressed and
the remaining 9 digits are transmitted with the ISBN check digit calculated by the
decoder.
UPC/EAN CONVERTED IN ISBN
UPC/EAN TRANSMITTED AS AN UPC/EAN *
START OF CONFIGURATION
END OF CONFIGURATION
34
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.5. Monarch/Codabar
The Codabar (or Monarch) is a very high reliable bar code which has been designed
specially for medical applications such as blood bag identification.
Its character set contains numerics and four symbols.
3.5.1. Start/Stop
TRANSMITTED
NOT TRANSMITTED *
ABCD BLOCK
a b c d Small *
a, b, c, d are the different start/stop characters.
3.5.2. Concatenation
STANDARD
CONCATENATED *
This function permits the capture of two codes with only one scan. Codes must be
close to one another and on the same "line".
Once captured, the two codes are assembled and transmitted as one message.
! Note:
To operate this function correctly, the first code must end with the "d" stop
character and the second code must start with the "d" start character. These two
start/stop characters are cleared before transmission.
START OF CONFIGURATION
END OF CONFIGURATION
35
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.6. Code 128
This symbology offers a great flexibility with its three sets of characters:
• Set A: upper case alphanumeric characters and all ASCII control characters.
• Set B: upper and lower case alphanumeric characters and some symbols.
• Set C: numeric only but which a very high density of characters per inch.
Good quality printed codes are recommended due to the continuous structure (no gaps
between characters) and the four types of bar and space widths.
It works with a modulo 103 check character as the last character.
! Note:
The UCC/EAN 128 options are described on next page.
3.6.1. Check Character
NOT VERIFIED BUT TRANSMITTED
VERIFIED BUT NOT TRANSMITTED *
VERIFIED AND TRANSMITTED
3.6.2. FNC2 Function
This function permits the temporary storage of a code in the decoder if this code
starts with the FNC2 character. The message buffered will be concatenated and
transmitted with next code having no FNC2 character.
FNC2 ACTIVATED
FNC2 NOT ACTIVATED *
START OF CONFIGURATION
END OF CONFIGURATION
36
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.7. UCC/EAN 128
This symbology is fully compatible with Code 128. The main difference between EAN 128
and conventional Code 128 is that EAN 128 codes always contain a reserved non-data
character, function 1 (FNC1), as the first character after the start character. This FNC1
character acts also as a separator of fields in the code.
Example of code UCC/EAN 128 structure:
START
FNC1
ID – DATA 1
FNC1
ID – DATA 2
CK
STOP
START: Start character from set A, B or C
FNC1 : Separator character
ID
: Identifier of type of data
: Check digit modulo 103
CK
STOP : Stop character
The decoder detects an UCC/EAN 128 code when FNC1 is the leading character.
The transmission of the data string will be performed as follow:
] C1
ID – DATA 1
GS
ID – DATA 2
] C1
GS
: Three characters representing the identifier of the code UCC/EAN 128
: ASCII character (1D hexa) acting as a separator
! Note:
In Keyboard-Wedge mode, the character GS is transmitted as quotes " (22 hexa).
The character FNC1 can be transmitted or not using these codes:
FNC1 TRANSMITTED
FNC1 NOT TRANSMITTED *
START OF CONFIGURATION
END OF CONFIGURATION
37
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.8. Standard 2/5
This symbology is numeric only and uses the same encoding system as the code
Interleaved 2/5 but only the bars are significant. The problem of reliability is also the same
in case of incomplete scanning of a code so it has to be used with fix length(s).
3.8.1. Number of Lengths Authorized
TWO
ONE *
To fix the number of characters per length, read one (or two) bar code label(s)
having the desired length(s) after the decoder is turned on.
! Note:
The length(s) are not saved after power-off.
3.8.2. Start/Stop Types
Two types of start/stop characters can be used, select the one corresponding to
your application:
WITH 2 BARS
WITH 3 BARS *
START
STOP
START
STOP
START OF CONFIGURATION
END OF CONFIGURATION
38
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.9. MSI
This symbology is mainly used in libraries to trace the loan of books. It is only numeric and
due to its very simple encoding system it can be used only with fixed length or with
variable lengths when including one or two check digits.
3.9.1. Variable or Fix Lengths
ONE FIXED LENGTH SET BY READING
A LABEL AFTER POWER-ON
VARIABLE LENGTHS *
! Note:
The length is not saved after power-off.
3.9.2. Double Check Digit (Modulo 10)
VERIFIED AND BOTH TRANSMITTED
VERIFIED BUT NOT TRANSMITTED *
BOTH VERIFIED BUT ONLY
FIRST ONE TRANSMITTED
NOT VERIFIED
3.9.3. Single Check Digit (Modulo 10)
VERIFIED AND TRANSMITTED
VERIFIED BUT NOT TRANSMITTED
START OF CONFIGURATION
END OF CONFIGURATION
39
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.10. Plessey
This was the first bar code symbology invented in the UK during the early 70's to control
the loan of library books.
The character set is numeric and its encoding system is very simple (thin bar = 0, large bar
= 1). It can be only read with two check digits as last characters.
CHECK DIGIT NOT TRANSMITTED
CHECK DIGIT TRANSMITTED *
3.11. Telepen
Mainly used in UK, this symbology has two separated sets of characters; one is numeric
and the other is alphanumeric. Use the codes below to activate the set desired.
NUMERIC
ALPHANUMERIC *
3.12. Code 93
The 128 ASCII characters can be encoded using this symbology which is more dense than
Code 39. Two check digits are always encoded as the last characters and are verified by
the decoder but not transmitted.
Its Multiread function permits the concatenation of codes in the decoder for those that start
with a space character. These will be transmitted upon the reading of a code having no
leading space character.
MULTIREAD NOT ACTIVATED
MULTIREAD ACTIVATED *
START OF CONFIGURATION
END OF CONFIGURATION
40
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.13. Matrix 2/5
This is a numeric and a more dense code than the Standard 2/5. Each character is
encoded with three bars and two spaces. It is advised to use it with fixed lengths or with a
check digit.
3.13.1. Types of Start/Stop
WITH 2 BARS
WITH 3 BARS *
START
STOP
START
STOP
3.13.2. Check Digit
VERIFIED BUT NOT TRANSMITTED
VERIFIED AND TRANSMITTED *
NOT VERIFIED
! Caution:
The mode Check Digit Not Verified is not advised, missing characters can occur in
case of incomplete scanning of a code.
3.13.3. Fixed or Variable Lengths
FIXED
VARIABLE *
In case that fixed lengths have been set, go to next page to adjust the number of
characters per length.
START OF CONFIGURATION
END OF CONFIGURATION
41
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.13.4. Setting the Authorized Lengths
FIRST LENGTH SELECTED
ACCESS CODE
FIRST LENGTH
Enter the desired number of characters
using the Numeric Pad page 81
VALIDATION
SECOND LENGTH SELECTED
ACCESS CODE
SECOND LENGTH
Enter the desired number of characters
using the Numeric Pad page 81
VALIDATION
START OF CONFIGURATION
END OF CONFIGURATION
42
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.14. IATA
This code is used by the airline and railway companies and are printed at the bottom of
each ticket. It is in fact a Standard 2/5 code with 2 bar start/stop characters.
Once activated (see Symbology Selection, chapter 3.1), only codes with 15, 17, 19 or 21
characters can be decoded.
3.15. BC 412
This symbology has been developed by IBM and is reserved for IBM and authorized
companies only. To decode it the decoder must be equipped with specific firmware
available on request, accompanied with an authorization letter from IBM.
It uses a check digit being the second character in the code which is verified and
transmitted or not depending of the option selected.
CHECK DIGIT TRANSMITTED
CHECK DIGIT NOT TRANSMITTED *
3.16. 3W7
Mainly used in Italy, this symbology has a set of 28 characters (numeric, letters A to F, a
few symbols and ASCII control characters).
A check digit modulo 28 is used as the last character in the code which is always verified
but not transmitted.
START OF CONFIGURATION
END OF CONFIGURATION
43
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.17. Leading Identifiers
They are characters added by the decoder to the leading positions of each code which
inform the host system of the type of symbology decoded. For example, they can be used
when several codes with different symbologies appear on a product or document.
Two types of identifiers can be used:
3.17.1. Identifier with One Character
TRANSMITTED
NOT TRANSMITTED *
Symbology
Identifier
Symbology
Telepen
Identifier
Code 39
A
S
I
B
G
Q
T
Pharmacode
Interleaved 2/5
UPC/EAN
Monarch/Codabar
Code 128
Code 93
Matrix 2/5
IATA
E
F
C
J
BC 412
U
X
3W7
EAN 128
Reserved # 1
Reserved # 2
Reserved # 3
V
Standard 2/5
MSI
R
M
P
W
Y
Plessey
3.17.2. Identifier with Three Characters
TRANSMITTED
NOT TRANSMITTED *
The first character is ] (5D hexa), the second one identifies the type of symbology
read, the third one indicates an option in the symbology. Please consult the AIM
standard to obtain the complete list of identifiers.
START OF CONFIGURATION
END OF CONFIGURATION
44
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3.18. Decoding Selectivity
This function can be used to fully optimize the reliability of decoding when poor printed
codes are used.
Once activated, the decoder performs three data captures and three decodes then
compares them before transmission.
MAXIMUM SELECTIVITY
(3 captures, 3 decodes)
MINIMUM SELECTIVITY *
(one capture, one decode)
START OF CONFIGURATION
END OF CONFIGURATION
45
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Page intentionally left blank
START OF CONFIGURATION
END OF CONFIGURATION
46
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4.
OPERATING MODES
The default operating mode of the IS1000 is the "Simple Acknowledgment".
Other operating modes can be selected by using the following sequence:
Read the code Start of Configuration
bottom left of each page
Select the desired operating mode
Adjust the timers value
Read the code End of Configuration
bottom right of each page
4.1. Simple Acknowledgment
SIMPLE ACKNOWLEDGMENT *
• Timer T1 = 200 ms (default value). To configure it, see page 51.
START OF CONFIGURATION
END OF CONFIGURATION
47
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2. Host System Acknowledgment
HOST SYSTEM ACKNOWLEDGMENT
ACK/NAK PROTOCOL ACTIVATED
• Timer T1 = 200 ms (default value). To configure it, see page 51.
• Timer T2 = 3 s (default value). To configure it, see page 52.
• Timer T3 = 2 s (default value). To configure it, see page 52.
4.3. On File / Not On File
ACTIVATED
DISACTIVATED
ON FILE / NOT ONFILE
• Timer T1 = 200 ms (default value). To configure it, see page 51.
• Timer T2 = 3 s (default value). To configure it, see page 52.
• Timer T3 = 2 s (default value). To configure it, see page 52.
START OF CONFIGURATION
END OF CONFIGURATION
48
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4.3.1. Setting the On File Character
This function can be used to change the On File Character sends by the host.
By default: Character ~ (7E hexa).
ACCESS CODE
ON FILE CHARACTER
Enter the desired character
using the Code 39 Full ASCII Table page 70
VALIDATION
4.3.2. Setting the Not On File Character
This function can be used to change the Not On File Character sends by the host.
By default: Character DEL (7F hexa).
ACCESS CODE
NOT ON FILE CHARACTER
Enter the desired character
using the Code 39 Full ASCII Table page 70
VALIDATION
START OF CONFIGURATION
END OF CONFIGURATION
49
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4.4. Bell
ACTIVATED
DISACTIVATED
BELL
• Timer T1 = 200 ms (default value). To configure it, see page 51.
• Timer T2 = 3 s (default value). To configure it, see page 52.
START OF CONFIGURATION
END OF CONFIGURATION
50
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4.5. Setting the Timers
Default Value
Timer T2
Operating Mode
Timer T1
200 ms
Timer T3
Simple Acknowledgment
Host System Acknowledgment
On File / Not On File
Bell
200 ms
3 s
3 s
3 s
2 s
2 s
200 ms
200 ms
4.5.1. Timer T1
Default value = 200 ms
ACCESS CODE TIMER T1
Enter the desired value
using the Numeric Pad page 81
(Step of 10 ms)
10 ≤ value ≤ 254
VALIDATION
START OF CONFIGURATION
END OF CONFIGURATION
51
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4.5.2. Timer T2
Default value = 3 s
ACCESS CODE TIMER T2
Enter the desired value
using the Numeric Pad page 81
(Step of 100 ms)
10 ≤ value ≤ 254
VALIDATION
4.5.3. Timer T3
Default value = 2 s
ACCESS CODE TIMER T3
Enter the desired value
using the Numeric Pad page 81
(Step of 100 ms)
10 ≤ value ≤ 254
VALIDATION
START OF CONFIGURATION
END OF CONFIGURATION
52
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
5.
EDITING MODE
START OF CONFIGURATION
END OF CONFIGURATION
53
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
START OF CONFIGURATION
END OF CONFIGURATION
54
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.
APPENDIXES
6.1. Radio Parameters
6.1.1. Radio Channel
Channel Number
Frequency
433.4 MHz
433.6 MHz
433.8 MHz
1
2
3
4
5
6
434.0 MHz
434.2 MHz
434.4 MHz
CHANNEL 1
CHANNEL 3 *
CHANNEL 5
CHANNEL 2
CHANNEL 4
CHANNEL 6
START OF CONFIGURATION
END OF CONFIGURATION
55
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.1.2. Number of Re-transmissions
Maximum number of bar code re-transmission attempts by the IS1000.
0
2
4
6
1
3 *
5
7
START OF CONFIGURATION
END OF CONFIGURATION
56
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.2. Adjustment of the Beep Sound
6.2.1. Laser Reader
VOLUME LOW
VOLUME HIGH *
6.2.2. Radio Base
VOLUME MEDIUM
VOLUME HIGH *
VOLUME LOW
VOLUME OFF
DURATION MEDIUM (60 ms)
DURATION LONG (120 ms) *
DURATION SHORT (20 ms)
DURATION VERY SHORT (5 ms)
START OF CONFIGURATION
END OF CONFIGURATION
57
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.3. Preamble / Postamble
One or several characters (22 maximum) can be systematically added to each message
as Preamble (leading positions) or as Postamble (ending positions) before transmission to
the host system.
These characters can be chosen from the Code 39 Full ASCII Table (see appendix 6.10,
page 70) when ASCII characters are required or from the Code 39 Full ASCII Extended
Table (see appendix 6.8, page 65) to emulate function keys in Keyboard-Wedge mode.
6.3.1. Preamble Character
ACCESS CODE PREAMBLE BUFFER
Enter the Preamble character(s)
using the Code 39 Full ASCII Table page 70 or
the Code 39 Full ASCII Extended Table page 65
6.3.2. Postamble Character
ACCESS CODE POSTAMBLE BUFFER
Enter the Postamble character(s)
using the Code 39 Full ASCII Table page 70 or
the Code 39 Full ASCII Extended Table page 65
6.3.3. Clear Buffer
To clear a buffer, read the corresponding access code then read the code Clear
Buffer Pre-selected.
CLEAR BUFFER PRE-SELECTED
START OF CONFIGURATION
END OF CONFIGURATION
58
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.4. Conversion of Characters
6.4.1. First Character
A first character can be converted into another defined by the user with the codes
on this page (see next page for changing a second one).
Example:
The user wants to convert all Q characters found in an input message into A.
Input message Q10Q234 will be changed into output message A10A234.
ACCESS CODE
FIRST CHARACTER TO BE CONVERTED
Enter the desired character
using the Code 39 Full ASCII Table page 70
VALIDATION
ACCESS CODE
NEW CHARACTER DESIRED
Enter the desired character
using the Code 39 Full ASCII Table page 70
VALIDATION
START OF CONFIGURATION
END OF CONFIGURATION
59
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Read this code to clear a pre-programmed conversion of a first character.
CONVERSION OF FIRST CHARACTER
CLEARED
START OF CONFIGURATION
END OF CONFIGURATION
60
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.4.2. Second Character
ACCESS CODE
SECOND CHARACTER TO BE CONVERTED
Enter the desired character
using the Code 39 Full ASCII Table page 70
VALIDATION
ACCESS CODE
NEW CHARACTER DESIRED
Enter the desired character
using the Code 39 Full ASCII Table page 70
VALIDATION
Read this code to clear a pre-programmed conversion of a second character.
CONVERSION OF SECOND CHARACTER
CLEARED
START OF CONFIGURATION
END OF CONFIGURATION
61
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.5. Rolling Buffer Mode
In this mode, the input data is first stored in the buffer of the decoder (up to 3K characters
maximum) and transmitted to the host system at a rhythm fixed by the inter-message time-
out selected on this page.
It can be useful when the data transmission speed to the host system is slow (specially in
Keyboard-Wedge mode) while a group of bar code labels has to be read very quickly
(example: carton on a conveyor…) or while a group of RS232 input messages has to be
first collected before transmission to the host system.
100 ms
NO TIME-OUT *
200 ms
500 ms
700 ms
1 SECOND
2 SECONDS
5 SECONDS
10 SECONDS
1.5 SECONDS
3 SECONDS
7 SECONDS
START OF CONFIGURATION
END OF CONFIGURATION
62
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.6. Transmission of the Full ASCII Character Set
This function releases the transmission of the 96 printable ASCII characters (20 to 7F hexa)
to the host system in any communication mode. The purpose of this function is to verify
that all characters are correctly emulated by the decoder specially in Keyboard-Wedge
mode.
ASCII TABLE TRANSMISSION ACTIVATED
START OF CONFIGURATION
END OF CONFIGURATION
63
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.7. Displaying the Firmware Level
Once the IS1000 radio base is connected to a host system with communication
parameters correctly adjusted, the level of the firmware implemented in the IS1000 laser
reader, radio base and its decoder can be displayed.
LASER READER AND RADIO BASE
The message will appear as follow:
Portable=X.XX - - Base=X.XX
RADIO BASE DECODER
The message will appear as follow:
FIRMWARE LEVEL: XXX.XX
START OF CONFIGURATION
END OF CONFIGURATION
64
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.8. Code 39 Full ASCII Extended Table
●A
●B
●D
●F
●H
●J
●L
FIELD EXIT
FIELD ADVANCE
●C
ENTER
SEND
●E
TAB -
RETURN
●G
RESET, RESTORE
HOME
●I
t
s
v
●K
u
●M
CLEAR
65
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
●N
●P
●R
●T
●V
●X
●O
●Q
●S
●U
●W
●Y
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
●Z
RESERVED
66
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.9. Multiread character Table
0
SPACE *
1
3
5
7
9
B
2
4
6
8
A
C
E
D
67
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
F
H
J
G
I
K
M
O
Q
S
U
L
N
P
R
T
68
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
V
X
Z
.
W
Y
-
*
$
/
+
%
69
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.10. Code 39 Full ASCII Table
Translation and values of the bar codes which appear on the next pages.
ASCII
Code 39
Hexa Value
ASCII
Code 39
Hexa Value
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
%U
$A
$B
$C
$D
$E
$F
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
SP
!
Space
/A
/B
/C
/D
/E
/F
/G
/H
/I
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
"
#
$
%
&
'
$G
$H
$I
(
HT
)
LF
$J
*
/J
VT
$K
$L
+
,
/K
/L
-
FF
CR
$M
$N
$O
$P
$Q
$R
$S
$T
-
SO
.
.
SI
/
/O
0
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
0
1
2
3
4
5
6
7
8
9
:
1
2
3
4
$U
$V
$W
$X
$Y
$Z
5
6
7
8
9
SUB
ESC
FS
/Z
%F
%G
%H
%I
%J
%A
%B
%C
%D
%E
;
<
=
>
?
GS
RS
US
70
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Translation and values of the bar codes which appear on the next pages.
ASCII
Code 39
Hexa Value
ASCII
Code 39
Hexa Value
@
A
B
C
D
E
F
G
H
I
%V
A
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
`
a
b
c
d
e
f
%W
+A
+B
+C
+D
+E
+F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
B
C
D
E
F
G
H
g
h
i
+G
+H
+I
I
J
J
j
+J
K
L
K
k
l
+K
+L
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
M
N
m
n
o
p
q
r
+M
+N
+O
+P
+Q
+R
+S
+T
O
P
Q
R
S
s
t
T
U
u
v
w
x
y
z
{
+U
+V
+W
+X
+Y
+Z
V
W
X
Y
Z
%K
%L
%M
%N
%O
%P
%Q
%R
%S
%T
\
|
]
}
^
~
DEL
_
71
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
NUL
STX
EOT
ACK
BS
SOH
ETX
ENQ
BEL
HT
LF
VT
FF
CR
SO
SI
72
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
DLE
DC2
DC4
SYN
CAN
SUB
FS
DC1
DC3
NAK
ETB
EM
ESC
GS
RS
US
73
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
SP
!
#
%
'
"
$
&
(
)
*
+
,
-
.
/
74
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
0
2
4
6
8
:
1
3
5
7
9
;
<
=
>
?
75
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
@
B
D
F
A
C
E
G
I
H
J
K
M
O
L
N
76
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
P
R
T
V
X
Z
\
Q
S
U
W
Y
[
]
^
_
77
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
`
b
d
f
a
c
e
g
i
h
j
k
m
o
l
n
78
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
p
q
r
s
t
u
v
x
z
l
w
y
{
}
~
DEL
79
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Page intentionally left blank
80
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.11. Numeric Pad
For entering variable data while configuration.
0
2
4
6
8
1
3
5
7
9
81
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6.12. Samples of Bar Codes
CODE 39
INTERLEAVED 2/5
CODABAR
CODE 128
EAN 128
82
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
UPC E
UPC A
UPC A with ADD-ON of 5 characters
EAN 8
EAN 13
EAN 13 with ADD-ON of 5 characters
83
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Page intentionally left blank
84
IS1000 – Configuration Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
|