Service
This manual is to be used by qualified appliance
technicians only. Maytag does not assume any
responsibility for property damage or personal
injury for improper service procedures done by
an unqualified person.
This Base Manual covers general information
Refer to individual Technical Sheet
for information on specific models
2004 - RCS/RFS
Commercial
Microwave
Ovens
This manual includes, but is
not limited to the following:
RCS10DA
RCS10MPA
RCS10A
P1330201M
P1330202M
P1330203M
P1330204M
RCS10PBDA
RCS10MPSA P1330205M
RFS12MPSA P1330206M
RFS12SW2A P1330208M
RFS10SW2A P1330232M
16023293
November 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Important Information .................................................... 2
Important Safety Information ......................................... 4
Grounding Instructions ............................................... 7
Servicing of Grounded Products................................. 8
Wiring ........................................................................ 8
Proper Grounding and Polarization of
Disassembly Procedures
Disconnecting Wire Terminals ..................................25
Outer Case ...............................................................25
DoorAssembly .........................................................26
Door Disassembly ....................................................26
Control Removal .......................................................27
Interlock Switches ....................................................27
H.V. Capacitor ..........................................................28
Diode ........................................................................28
Transformer ..............................................................29
Fuse / Fuse Block / Filter Assembly ........................29
Magnetron ................................................................29
Blower Motor or Wheel .............................................30
Splatter Shield ..........................................................30
Antenna ....................................................................30
Stirrer Motor..............................................................30
Magnetron Thermal Cut-Out (TCO) ...........................31
Cavity Thermal Fuse .................................................31
Tray Replacement.....................................................31
Oven Light Removal ..................................................31
AppendixA
120 Volts Wall Outlets............................................ 8
Explanation ............................................................... 8
Test Procedures (2 Methods) ..................................... 8
General Test Information ............................................ 8
General Information
Unpacking Equipment................................................ 9
Equipment Placement ............................................... 9
Radio Interference ...................................................... 9
Oven Features ........................................................... 9
Model Identification ...................................................10
Service ......................................................................10
Parts and Accessories..............................................10
Troubleshooting Procedures ................................... 11-16
Service Information
Proper Handling of Magnetron Tubes ........................17
Magnetron Failure Mode ...........................................17
Microwave LeakageTest
Quick Reference Guide Dial Model ......................... A-2
Quick Reference Guide Electronic Model ............... A-4
Equipment ................................................................18
Procedure For Measuring Radiation Leakage ...........18
Measurement With the Outer Panel Removed ..........18
Measurement With a FullyAssembled Oven ............18
Record Keeping and Notification
After Measurement ................................................18
Troubleshooting
Operating Instructions for Holaday
HI1501, HI1510, and HI1710 ..................................19
Testing Procedures ................................................. 20-23
Power Test................................................................24
©2004 Maytag Services
16023293 Rev. 0
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Information
WARNING
!
Read the following information to avoid possible exposure to microwave radiation:
The basic design of theAmana Microwave Oven makes it an inherently safe device to both use and service.
However, there are some precautions which should be followed when servicing the Microwave Oven to maintain this
safety. These are as follows:
8. Do not for any reason defeat the interlock
switches there is not a valid reason for this action
at anytime; nor will it be condoned by Maytag.
1. Always operate the unit from an adequately
grounded outlet. Do not operate on a two-wire
extension cord.
9. IMPORTANT: Before returning a unit to a
customer, be sure to check for proper switch
interlock action.
2. Before servicing the unit (if unit is operable) perform
the microwave leakage test.
3. The oven should never be operated if the door does
not fit properly against the seal, the hinges or hinge
bearings are damaged or broken; the choke is
damaged, (pieces missing, etc.); or any other
visible damage can be noted. Check the choke
area to ensure that this area is clean and free of all
foreign matter.
10. Before returning a unit to a customer, verify that
the door spacing is reasonably uniform along the
top, bottom, and sides, and that it measure
1/64"/0.5mm or less.
11. Microwave ovens should never be operated with
any components removed and/or bypassed or
when any of the safety interlocks are found to be
failing or when any of the seal surfaces are failing,
missing or damaged.
4. If the oven operates with the door open and
produces microwave energy, take the following
steps:
A. Tell the user not to operate the oven.
B. Contact Maytag immediately.
12. All microwave ovens meet all requirements of the
radiation control for Health and SafetyAct of 1968.
Due to measurement uncertainties, the maximum
leakage for the field will be 4mw/cm2.
5. Always have the oven disconnected when the outer
case is removed except when making the "live"
tests called for in this Service Manual. Do not
reach into the equipment area while the unit is
energized. Make all connections for the test and
check them for tightness before plugging the cord
into the outlet.
13. To ensure that the unit does not emit excessive
microwave leakage and to meet the Department
of Health and Human Services guidelines, check
the oven for microwave leakage using a leakage
monitor. The maximum leakage level allowed
when following those instructions is 4mw/cm2.
6. Always ground the capacitors on the magnetron
filter box with an insulated-handle screwdriver
before working in the high voltage area of the
equipment compartment. Some types of failures
will leave a charge in these capacitors and the
discharge could cause a reflex action which could
make you injure yourself.
14. If servicer encounters an emission reading over
4mw/cm2, the servicer is to cease repair and
contact the Commercial Support Center
immediately for further direction. Maytag will
contact the proper GovernmentAgency upon
verification of the test results.
7. Always remember that in the area of the
transformer there is HIGH VOLTAGE. When the
unit is operating keep this area clear and free of
anything which could possibly cause an arc or
ground, etc.
4
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Information
Recognize this symbol as a SAFETY message
WARNING
!
When using electrical equipment, basic safety precautions should be followed to reduce the risk of burns,
electrical shock, fire, or injury to persons.
1. READ all instructions before using equipment.
8. DO NOT operate this equipment if it has a
damaged cord or plug, if it is not working
properly, or if it has been damaged or dropped.
2. READ AND FOLLOW the specific
“PRECAUTIONS TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE
ENERGY”.
9. This equipment, including power cord, must be
serviced ONLY by qualified service personnel.
Special tools are required to service equipment.
Contact nearest authorized service facility for
examination, repair, or adjustment.
3. This equipment MUST BE GROUNDED. Connect
only to properly GROUNDED outlet. See
“GROUNDING INSTRUCTIONS”.
10. DO NOT cover or block filter or other openings
4. Install or locate this equipment ONLY in
accordance with the installation instructions in this
manual.
on equipment.
11. DO NOT store this equipment outdoors. DO
NOT use this product near water, for example,
near a kitchen sink, in a wet basement, or near
a swimming pool, and the like.
5. Some products such as whole eggs and sealed
containers, for example, closed glass jars may
explode and SHOULD NOT be HEATED in this
oven.
12. DO NOT immerse cord or plug in water.
6. Use this equipment ONLY for its intended use as
described in this manual. Do not use corrosive
chemicals or vapors in this equipment. This type
of oven is specifically designed to heat or cook. It
is not designed for industrial or laboratory use.
13. Keep cord AWAY from HEATED surfaces.
14. DO NOT let cord hang over edge of table or
counter.
15. See door cleaning instructions in “Care and
Cleaning” section.
7. As with any equipment, CLOSE SUPERVISION
is necessary when used by CHILDREN.
16. For commercial use only.
CAUTION
!
To reduce risk of fire in the oven cavity:
a. DO NOT overcook food. Carefully attend
equipment if paper, plastic, or other combustible
materials are placed inside the oven to facilitate
cooking.
c. KEEP oven DOOR CLOSED, turn oven off, and
disconnect the power cord, or shut off power at
the fuse or circuit breaker panel, if materials
inside the oven should ignite. Fire may spread
if door is opened.
b. Remove wire twist-ties from paper or plastic
bags before placing bag in oven.
d. DO NOT use the cavity for storage. DO NOT
leave paper products, cooking utensils, or food
in oven.
SAVE THESE INSTRUCTIONS
©2004 Maytag Services
16023293 Rev. 0
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Information
CAUTION
!
To avoid risk of personal injury or property damage, observe the following:
1. Briskly stir or pour liquids before heating with
microwave energy to prevent spontaneous boiling
or eruption. Do not overheat. If air is not mixed
into a liquid, liquid can erupt in oven or after
removal from oven.
7. Do not use regular cooking thermometers in oven.
Most cooking thermometers contain mercury and
may cause an electrical arc, malfunction, or
damage to oven.
8. Do not heat baby bottles in oven.
9. Do not use metal utensils in oven.
2. Do not deep fat fry in oven. Fat could overheat
and be hazardous to handle.
10. Never use paper, plastic, or other combustible
materials that are not intended for cooking.
3. Do not cook or reheat eggs in shell or with an
unbroken yolk using microwave energy. Pressure
may build up and erupt. Pierce yolk with fork or
knife before cooking.
11. When cooking with paper, plastic, or other
combustible materials, follow manufacturer's
recommendations on product use.
4. Pierce skin of potatoes, tomatoes, and similar
foods before cooking with microwave energy.
When skin is pierced, steam escapes evenly.
12. Do not use paper towels which contain nylon
or other synthetic fibers. Heated synthetics could
melt and cause paper to ignite.
5. Do not operate equipment without load or food in
oven cavity.
13. Do not heat sealed containers or plastic bags
in oven. Food or liquid could expand quickly and
cause container or bag to break. Pierce or open
container or bag before heating.
6. Use only popcorn in packages designed and
labeled for microwave use. Popping time varies
depending on oven wattage. Do not continue to
heat after popping has stopped. Popcorn will
scorch or burn. Do not leave oven unattended.
14. To avoid pacemaker malfunction, consult
physician or pacemaker manufacturer about
effects of microwave energy on pacemaker.
PRECAUTIONS TO AVOID POSSIBLE EXPOSURE
TO EXCESSIVE MICROWAVE ENERGY
a. DO NOT attempt to operate this oven with the
door open since open-door operation can result in
harmful exposure to microwave energy. It is
important not to defeat or tamper with the safety
interlocks.
c. DO NOT operate the oven if it is damaged. It
is particularly important that the oven door close
properly and that there is no damage to the: (1)
door (bent), (2) hinges and latches (broken or
loosened), (3) door seals and sealing surfaces.
b. DO NOT place any object between the oven front
face and the door or allow soil or cleaner
d. The oven should NOT be adjusted or repaired
by anyone except properly qualified service
personnel.
residue to accumulate on sealing surfaces.
SAVE THESE INSTRUCTIONS
6
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Information
Grounding Instructions
!
WARNING
Precautions to be observed before and during
servicing to avoid possible exposure to excessive
microwave energy, or electrical shock disconnect
power to oven.
!
WARNING
Do not remove grounding prong when installing
grounded appliance in a home or business that does
not have three wire grounding receptacle, under no
condition is grounding prong to be cut off or removed.
It is the personal responsibility of the consumer to
contact a qualified electrician and have properly
grounded three prong wall receptacle installed in
accordance with appropriate electrical codes.
• Do not operate or allow oven to be operated with door
open.
• Make the following safety checks on all ovens to be
serviced before activating the magnetron or other
microwave source, and make repairs as necessary:
• Interlock operation
• Proper door closing
• Seal and sealing surfaces (arcing, wear, and
other damage)
• Damage to or loosening of hinges and latches
• Evidence of dropping or abuse
WARNING
!
To avoid the risk of electrical shock or death, do not
alter the plug.
• Before turning on microwave power for any service
test or inspection within the microwave generating
compartments, check the magnetron, waveguide or
transmission line, and cavity for proper alignment,
integrity, and connections.
WARNING
!
To avoid the risk of electrical shock or death, this
equipment must be grounded.
• Any failed or misadjusted components in the
interlock, monitor, door seal, and microwave
generation and transmission systems shall be
repaired, replaced or adjusted by procedures
described in this manual before oven is released to
the consumer.
• Check microwave leakage to verify compliance with
the federal performance standard should be
performed on each oven prior to release to the
consumer.
This equipment MUST be grounded. In the event of an
electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the
electric current. This oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.
Consult a qualified electrician or servicer if grounding
instructions are not completely understood, or if doubt
exists as to whether the equipment is properly
grounded.
Do not use an extension cord. If the product power cord
is too short, have a qualified electrician install a three-
slot receptacle. This oven should be plugged into a
separate 60 hertz circuit with the electrical rating as
shown in the appropriate drawing. Models operate with a
120 supply voltage. When a microwave oven is on a
circuit with other equipment, an increase in cooking
times may be required and fuses can be blown.
!
WARNING
To avoid risk of electrical shock, injury or death; make
sure these grounding instructions are followed.
NEMA 5-15R/5-15P
120V–15AMP
NEMA 5-20R/5-20P
120V–20AMP
©2004 Maytag Services
16023293 Rev. 0
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Information
Servicing of Grounded Products
Explanation
The standard accepted color coding for grounding wires
is GREEN or GREEN WITH YELLOW STRIPE. These
ground leads are NOT to be used as current carrying
conductors. It is extremely important that the technician
replace any and all grounds prior to completion of the
service call. Under no condition should ground wire be
left off causing a potential hazard to technicians and
consumer.
Polarization–This means that the larger slot must be
neutral and the small slot must be hot (live).
Mispolarized–Theoutletismiswiredsothatthelargerslot
is hot (live) and the smaller slot is neutral.
Grounded–This means the round hole connection is
connectedtoearthgroundthroughaconnectiontothemain
powerpanel.
Ungrounded–The round hole connection is not complete
to earth ground and/or the main power panel.
Wiring
Test Procedures (2 Methods)
Method #1
Use a ground monitor plug available for purchased at
local hardware store. The lamps inside the monitor
indicate a correctly or incorrectly wired outlet by
instructions imprinted on the monitor body.
A good service practice is never route wiring over
terminals and/ or sharp edges. This applies to any wiring
without regard to the circuit voltage. Wire installation
material and thickness is designed and regulated for
electrical spacing purpose only, but cannot always be
relied upon because of possible cuts and/or abrasions,
which can occur during servicing.
WARNING
!
To avoid risk of electrical shock, personal injury or
death; verify the oven is properly grounded and
polarized.
Proper Grounding and Polarization of
120 Volts Wall Outlets
Method #2
For the safety of our customers and the service
technician ALL appliances have a three–prong power
cord and MUST be connected to a properly polarized and
grounded wall outlet.
Voltmeter - (Use scale over 125 Volts A.C.)
• Test A - "H" to "N" must indicate line voltage.
• Test B - "H" to "G" must indicate line voltage.
• Test C - "N" to "G" must indicate zero (0) volts.
This information was written for those who do not
understand grounding and polarization of a wall outlet.
If "N" to "G" indicates line voltage the outlet is improperly
polarized.
A 120 volt wall outlet must always be wired as shown
below.
If "H" to "G" indicates zero (0) volts the outlet is not
grounded.
Neutral (N) - This slot is
the larger of the two and
should be neutral (dead)
with respect to ground.
Hot (H) - This slot is
the smaller size and
should always be hot
(live) with respect to
neutral (N) and ground(G).
CAUTION
!
H
N
To avoid risk of electrical shock, personal injury or
property damage; wiring changes or grounding of wall
outlet are to be made only by a qualified electrician.
G
Ground (G) - The round hole connection
is for the grounding circuit. Behind the
cover plate a green wire should be
connected to this terminal.
General Test Information
Most testing in the manual is conducted with an
ohmmeter using a multiplier scale of X 10k (k–thousand
ohms). When using this scale, it is important that your
fingers do not touch the metal parts of the test probes.
To do so will give a false indication of the ohm reading.
8
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
General Information
Unpacking Equipment
Radio Interference
Microwave operation may cause interference to radio,
television, or similar equipment. Reduce or eliminate
interference by doing the following:
• Inspect equipment for damage such as dents in door
or dents inside oven cavity.
• Report any dents or breakage to source of purchase
immediately. Do not attempt to use oven if damaged.
• Remove all materials from oven interior.
• Clean door and sealing surfaces of oven according to
instructions in “Care and Cleaning” section.
• Place radio, television, etc. as far as possible
from oven.
• Use a properly installed antenna on radio, television,
etc. to obtain stronger signal reception.
Equipment Placement
• Do not install equipment next to or above source of
heat, such as pizza oven or deep fat fryer. This could
cause microwave oven to operate improperly and
could shorten life of electrical parts.
Oven Features
• Do not block or obstruct air filter. Allow access for
cleaning.
• Install on level countertop surface.
Removable
Splatter Shield
(Not Shown)
A
Oven Door Window
and Interior Light
A
Oven Display
A
Oven Control
Pads
Filter
A—Allow at least 1½ inches / 3.81 centimeters of clearance
around top and sides of equipment. Proper air flow around
equipment cools electrical components. With restricted air
flow, oven may not operate properly and life of electrical
parts is reduced.
©2004 Maytag Services
16023293 Rev. 0
9
Download from Www.Somanuals.com. All Manuals Search And Download.
General Information
Model Identification
• ForAmana product call 1-866-426-2621 or visit the
When contacting for service support, provide product
information located on rating plate. Record the following:
Model Number:
___________________
___________________
___________________
___________________
Manufacturing Number:
Serial or S/N Number:
Date of purchase:
Dealer’s name and address: ___________________
Service
Keep a copy of sales receipt for future reference or in
case warranty service is required. To locate an
authorized servicer:
• ForAmana product call 1-866-426-2621 or visit the
Warranty service must be performed by an authorized
servicer. We also recommend contacting an authorized
servicer, if service is required after warranty expires.
Parts and Accessories
Purchase replacement parts and accessories over the
phone. To order accessories for your product contact
your local product distributor or vist the Web site at
10
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting Procedures
When you get a complaint from customers, evaluate the complaint carefully. If the following symptoms apply,
instruct the customer in the proper use of the microwave oven. This can eliminate an unnecessary service call.
CAUTION
!
• Verify proper earthing before checking for trouble.
• Be careful of the high voltage circuit.
• Discharge the high voltage capacitor.
• When checking the continuity of the switches or of the high voltage transformer, disconnect one lead wire from
these parts and then check continuity with the AC plug removed. To do otherwise may result in a false reading
or damage to your meter.
• Do not touch any part of the circuit on the controller, since static electric discharge may damage the control
panel. Always touch yourself to earth while working on this panel to discharge any static charge built up in your
body.
Condition
Cause
Remedy
Microwave oven does not work.
• Inserting multiple plugs into
one outlet and using them at
the same time (blown fuse or
breaker).
• Avoid using other electrical
appliances when you use the
microwave oven.
• Microwave oven plug is not
inserted tightly.
• Insert microwave oven plug
securely.
Output power is too low.
• Low AC input voltage.
• Use the microwave oven at
adequate line voltage.
• Food temperature is too low.
• This may not be a defect. It is
possible that the food should
be cooked for a longer time
period.
Sparks occur.
• Using metallic ware and
allowing it to touch the oven
wall.
• Do not use metallic ware for
cooking.
• Ceramic ware trimmed in gold
or silver is used.
• Do not use any type of
cookware with metallic
trimming.
Uneven cooking.
Inconsistent food thickness,
inconsistent fat or moisture
distribution within the food
products.
• Use plastic wrap or lid.
• Stir once or twice while
cooking soup, cocoa, milk, etc.
©2004 Maytag Services
16023293 Rev. 0
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting Procedures
Trouble 1: The following visual conditions indicate a probable failed control circuit.
1. Incomplete segments.
• Segment missing.
• Partial segment missing.
• Digit flickering (Note: Slight flickering is normal.)
2. Colon does not turn on or blink.
3. A distinct change in the brightness of one or more numbers in display.
4. One or more digits in the display are not lighting.
5. Display indicates a number different from one touched, for example, key in 5 and 3 appears in the display.
6. Specific numbers (for example 7 or 9) will not display when key pad is touched.
7. Display does not count down with time blinking or up with clock operation.
8. Display obviously jumps in time while counting down.
9. Display counts down too fast while cooking.
10.Each indicator light does not turn on after setting cooking cycle.
11.Display time of day does not reappear when cooking is finished.
Condition
No input can be
programmed.
Check
Check the connection
between keypad and
controller.
Result
• Continuity
• No continuity
Cause
Remedy
• Failed
• Replace
controller.
• Repair
connection.
• Replace
keypad.
controller.
• Loose
connection.
• Failed
1. Some inputs
cannot be
Replace keypad and check
operation.
• Everything
works as
keypad.
programmed.
2. Display shows
a number or
figure different
from one
specified.
• Still have
trouble.
• Failed
controller.
• Replace
controller.
touched.
3. Random
programming
when touching
other pads.
4. Display is fixed
at some figure
and can not
accept any
input.
12
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting Procedures (Electronic Models)
Trouble 2: Oven does not operate at all, display window does not display any digits, and
no input is accepted.
Malfunction
Replace the fuse,
primary,
secondary, monitor
switches and
controller.
Check continuity
of monitor switch
with door closed.
Continuity
of the
monitor
switch.
Fuse blows.
No
Continuity
Replace fuse
Replace the fuse,
primary,
secondary, monitor
switches and
controller.
Check continuity
of primary switch
with door opened.
Continuity
Malfunction of
primary switch.
No
Continuity
Check continuity
of secondary
switch with door
opened.
Malfunction of
secondary
switch.
Replace the fuse,
primary,
secondary, monitor
switches and
controller.
Continuity
No
Continuity
Disconnect one side of
Failed high
voltage
transformer.
Fuse blows
Replace high
voltage
transformer.
the wire lead connecting
transformer to high
voltage capacitor and
operate the unit.
again.
Failed high
voltage
capacitor.
Replace high
voltage
capacitor.
Abnormal
Normal
Measure
resistance of high
voltage capacitor.
Normal
Capacitor is good,
(replace fuse only).
Check continuity
of thermostat
(cavity and
No
Continuity
Replace
thermostat.
Failed
thermostat.
Fuse does not
blow.
magnetron).
No
Continuity
Replace
power cord.
Failed power
cord.
Check continuity
of power cord.
Continuity
©2004 Maytag Services
16023293 Rev. 0
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting Procedures (Electronic Models)
Trouble 3: Display shows all digits programmed, but does not start cooking when the
START pad is pressed.
Malfunction
of secondary
switch.
Check continuity
of secondary
switch with door
closed.
No
Continuity
Time does not
count down
after START
pad is pressed.
Replace the
secondary
switch.
Continuity
Failed
controller.
Replace
controller.
Check connection
between CN1
connector and
controller.
Continuity
Repair
connection.
Loose
connection.
No
Continuity
Normal
Failed fan
motor.
Replace fan
motor.
Check fan
motor.
Abnormal
Fan motor or
oven light does
not operate.
Failed oven
light.
Replace oven
light.
Check oven
light.
Abnormal
Normal
14
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting Procedures (Electronic Models)
Trouble 4: Oven operates with little or no heat.
Output
performance
is low.
Customer must
contact local
power
company or
qualified
Lower than
90% of rated
voltage.
Decrease in
supply voltage
under load.
Check the power
supply voltage.
electrician.
Normal
Failed
controller.
Replace
controller.
Abnormal
Normal
Disconnect wire leads
from relay RY2 and
verify on and off times.
Failed
magnetron
Replace
magnetron.
Measure the
output power.
Abnormal
NOTE: Simple test of power output can be conducted by heating one liter of water for one minute.
Refer to Power Test on page 24 of this manual.
©2004 Maytag Services
16023293 Rev. 0
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting Procedures (Electronic Models)
Trouble 5: No microwave oscillation even when oven light and fan motor operate.
Disconnect wire
leads from relay
RY2 and verify
continuity of the
relay.
Replace
controller.
No
Continuity
Failed
controller.
No microwave
oscillation.
Continuity
Check high
voltage
transformer.
Replace high
voltage
transformer.
Abnormal
Normal
Failed high
voltage
transformer.
Failed high
voltage
capacitor.
Check high
voltage capacitor.
Replace high
voltage capacitor.
Abnormal
Normal
Failed high
voltage
Check high voltage
diode.
Replace high
voltage diode.
Abnormal
Normal
diode.
Replace
magnetron.
Abnormal
Failed
magnetron.
Check magnetron.
Disconnect wire
leads from relay
RY2 and verify
continuity of the
relay.
Operates at
full power
when
programmed
for lower
power.
Replace
controller.
Failed
controller.
Abnormal
16
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Service Information
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
!
Proper Handling of Magnetron Tubes
2. Open Heater (Filament) - Can be determined by a
ohmmeter when transformer leads are
disconnected. Resistance is normally less than one
ohm; filament does not short internally. Any tube
removed should be checked since usage tends to
make the filament more fragile. Later handling and
shipping may open the filament and thereby mask
the true failure mode when checked at the factory.
3. Low Power - Caused by “wearout” of the emission
characteristics of the directly heated cathode.
Symptoms are: (1) tube current will take longer to
get to operating point then a new tube (normally
about 2 - 3 seconds), (2) tube current does not get
high enough to cause the tube to oscillate with
normal line voltage, (3) oven produces low power
into a load, two-thirds or less than normal.
CAUTION
!
A magnetron tube, like a radio or television tube
must be handled with a reasonable amount of care.
When handling a tube, always handle by the housing
only. Use caution not to touch or strike the ceramic
portion at the top. The carton used to ship service
replacement tubes is reusable.
Magnetron Failure Modes
Magnetron failures that have been identified are
generally grouped into categories shown below.
1. Shorted
Air - This is a case where the tube has had the vacuum
envelope destroyed and air has entered the tube.
This will cause internal arcing and high secondary
current if high voltage is applied.
4. Physical Damage - Caused by mishandling of
magnetron tube.
R.F. Capacitors - May short to chassis. This condition
will also cause loss of high voltage.
Output
Antenna
Ceramic
Fins
Anode
Block
Magnet
Terminals/R.F. Capacitors
Not Replaceable
Serial Number
©2004 Maytag Services
16023293 Rev. 0
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Microwave Leakage Testing
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
!
Measurement with the Outer Panel
Removed
WARNING
!
Check for radiation leakage after servicing. Should the
leakage be more than 4 mW/cm2 inform Maytag
immediately. After repairing or replacing any radiation
safety device, keep a written record for future reference,
as required by D.H.H.S. and HEW regulations. This
requirement must be strictly observed. In addition, the
leakage reading must be recorded on the service repair
ticket while in the customer’s home.
WARNING
!
Avoid contacting any high voltage components.
Whenever you replace the magnetron, measure for
radiation leakage before the outer panel is installed
and after all necessary components are replaced or
adjusted. Special care should be taken in measuring
around the magnetron.
Equipment
• Electromagnetic radiation monitor
• 600 cc glass beaker or plastic power bowl
Measurement with a Fully Assembled
Oven
After all components including the outer panel are fully
assembled, measure for radiation leakage around the
door periphery, the door viewing window, the exhaust
opening, and air inlet openings.
Procedure for Measuring Radiation Leakage
Note before measuring:
• Do not exceed meter full scale deflection. Leak monitor
should initially be set to the highest scale.
• To prevent false readings the test probe should be held
by the grip portion of the handle only.
• The scan speed is equal to one inch per antenna
revolution or one inch per second if antenna speed is
unknown.
• Areas to be checked are all door seal areas and any
venting parts.
• Leakage with the outer panel removed ...4mW/cm2 or
less.
Record Keeping and Notification After
Measurement
1. After any adjustment or repair to a microwave
oven, a leakage reading must be taken. Record
this leakage reading on the repair ticket even if it is
zero.
2. A copy of the repair ticket and the microwave
leakage reading should be kept by the repair
facility.
• Leakage for fully assembled oven with door normally
closed ...4 mW/cm2 or less.
• Leakage for a fully assembly oven (before the latch
switch (primary) is interrupted) while pulling the door
... 4 mW/cm2 or less.
1. Pour 275 cc 15 cc (9 oz 1/2 oz) of 20°C 5°C
(68°F 9°F) water in a beaker which is graduated to
600 cc and place the beaker in the center of oven.
2. Set the radiation monitor to 2450 MHz and use it
following the manufacturer’s recommended test
procedure to assure correct results.
3. While measuring the leakage, always use the two inch
(5 cm) spacer supplied with the probe.
4. Press the start pad or turn on the timer and with the
magnetron oscillating, measure the leakage by holding
the probe perpendicular to the surface being
measured.
18
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
!
Hold probe perpendicular to cabinet door. Place cone
Operating Instructions for the Holaday
of probe on the door and/or cabinet door seam and
HI1501, HI1510, HI1710, and HI1801
Purpose of these monitors is to check radiation
leakage around microwave oven door or other places
where radiation could possibly occur.
move along the seam. If leakage of the oven is
unknown, move probe slowly. Proceed with care in
order not to exceed a full scale reading of meter.
When testing near a corner or access area of door,
keep probe perpendicular to the areas making sure
probe end at the base of the cone does not get closer
than 2” (5cm) to any metal. If it does, an erroneous
reading may result.
Instrument measures radiation leakage in milliwatts
2
per square centimeters (mW/cm ). Probe should be
used with the 2" (5 cm) cone spacer. Water load of
275 cc. (approximately 1 1/3 cup), is to be placed in
the oven and used as a load during leakage tests.
Always use the 2” (5cm) spacer with probe. Also,
always proceed carefully in areas of high leakage or
probe can be accidentally burned-out. Rotating
antenna causes high peaks of energy. Although meter
has averaging capabilities, probe will react
instantaneously to peak power changes which will
cause burn-out.
Operate the instrument on its internal 9 Volt battery
power supply. “Range” switch is used on low and high
while using test probe. On an oven with an unknown
leakage, use high scale then switch to low scale and
test for low leakage. “Bat Test” switch is used to
check the battery and probe on the Holaday
Instruments. If either is faulty, meter needle will not
read above “Test Minimum” or battery mark on meter.
Holaday Instrument has a probe test switch position.
Meter needle must indicate in the “OK probe test”
portion of the scale when in this position. Zero control
is used to zero the needle. “ON-OFF” switch provides
a means of turning the operating voltage on or off.
“Range Multiplier” switch provides a means of
selection either 0-2 or 0-10 and 0-100 on the Holaday
Instruments sensitivity ranges.
NOTE: For further instructions see Amana Service
Letters of the R-10, R-35, and R-59 of your
Instrument Instruction Manual.
NOTE: Simpson Electric Company Model 380M may
also be used by using the above instructions
for guideline and the 380M Instruction
Manual.
Test probe must be held by the grip portion of the
handle, otherwise a false reading may result if
operators hand is between the handle and probe.
If oven is likely to have a large amount of leakage,
approach oven slowly with the probe, while observing
meter. This is achieved by holding the probe two or
three feet from oven surface or gap between door and
oven body while observing meter. When high leakage
is expected, do not move probe horizontally along the
oven surface. This could cause possible probe
burn-out. Greatest leakage is generally found at the
corners. After maximum leakage is established to be
within the meter scale range, then probe may be
moved horizontally around the door surface.
©2004 Maytag Services
16023293 Rev. 0
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Testing Procedures
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
!
Illustration
Component
Testing
Results
Thermal cutout
Disconnect all wires from TCO.
Measure resistance across terminals.
Cavity TCO............................................ Closed at 32°F (0°C) and
Opens at 230°F (110°C)
Closed at 140°F (60°C) and
Opens at 320°F (160°C)
Magnetron TCO.....................................
Diode
Discharge Capacitor
Infinite resistance should be
measured in one direction and 50KΩ
or more in the opposite direction.
Remove diode lead from capacitor and
connect ohmmeter.
NOTE: Ohmmeter must contain a
battery of 6 volts minimum.
Reverse leads for second test.
Capacitor
Discharge Capacitor
Remove wires from capacitor terminals
and connect ohmmeter, set on highest
resistance scale to terminals.
Between Terminals: Meter should
momentarily deflect towards zero
then return to over 5 MΩ. If no
deflection occurs, or if continuous
deflection occurs, replace capacitor.
Also check between each terminal and
capacitor case.
Terminal to Case: Infinite resistance
Magnetron
Discharge Capacitor
Between Terminals: Less than 1 Ω
Remove wires from magnetron and
connect ohmmeter to terminals. Also
check between each terminal and
ground.
Each terminal to ground measures
Infinite resistance.
Note: This test is not conclusive. If
oven does not heat and all other
components test good replace the
magnetron and retest.
Blower motor
Remove all wires from motor.
Measure resistance across coil ............. Approximately 14 – 21 Ω
Stirrer motor
Transformer
Remove all wires from motor.
Measure resistance across terminals .... Approximately 3 – 3.5 KΩ
Discharge Capacitor
Remove all wires from terminals.
Secondary
Filament
Measure resistance from:
Primary ................................................ Less than <1 Ω
Filament............................................... Less than <1 Ω
Secondary to Ground screw on
Primary
transformer stack.................................
Approximately 100 – 120 Ω
Noise filter board
6 minute timer
Power In terminals................................. 120 VAC
Power Out terminals.............................. 120 VAC
If no power in, check power outlet.
If no power out, check fuses.
If timer does not indicate readings
below, replace timer.
Remove leads from timer contact
terminals.
Measure resistance of following
terminals:
1 to 2⎯Timer in OFF position.................
1 to 2⎯Timer in ON position...................
3 to 4⎯Timer in OFF or ON position ......
Infinite Ω
Approximately <1 Ω
Approximately 11 KΩ (timer motor)
BELL
2
1
4
3
20
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Testing Procedures
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
!
Illustration
Component
Testing
Results
Interlock switch assembly
Disconnect wires to switch.
With door open measure resistance from:
Monitor - Terminal 3 - 4.......................... Indicates continuity
Primary - Terminal 1 - 2 ......................... Infinite Ω
3
Secondary - Terminal 5 - 6.....................
Infinite Ω
Monitor
4
1
2
With door closed measure resistance from:
Monitor - Terminal 3 - 4..........................
Primary - Terminal 1 - 2 .........................
Secondary - Terminal 5 - 6.....................
Infinite Ω
Indicates continuity
Indicates continuity
5
Primary
6
After verifying or replacing the
module, reconnect wires to switch
and check operation of monitor circuit
before operating the oven.
Secondary
Lamp receptacle
Test continuity of receptacle terminals.
Indicates continuity with bulb
installed.
Wire Harness
Test continuity of wires
Indicates continuity
Electronic Control Panel
Service Test Mode:
Open door, Press and Hold pad 3 for 5
seconds to enter service test mode.
Press Pad 1 ................................................
SERVICE appears in the display
Indicates number of hours
magnetron has been turned on
Indicates number of times
magnetron tube has been turned
on and off
Press Pad 2 ................................................
Indicates number of door cycles
CLEAR (Press START pad to
reset service data.)
Indicates amperage
N/A
RESET (Clear Service Alarm)
N/A
Press Pad 3 ................................................
Press Pad 4 ................................................
Press Pad 5 ................................................
Press Pad 6 ................................................
Press Pad 7 ................................................
Press Pad 8 ................................................
Press Pad 9 ................................................
Press Pad 0 ................................................
Stop/Reset Pad...........................................
N/A
N/A
Exit Service Test Mode
Error codes:
E-08 ............................................................ Replace Control Board
Replace Control Board
E-09 ............................................................
Shorted or Open Keypad – Test
and replace if necessary
E-10 ............................................................
Electronic Dial Control Panel
Service Test Mode:
Open door, Press and Hold Hidden Pad
2 for 5 seconds to enter service test
mode.
Press Hidden Pad 2 ....................................
Press Hidden Pad 2 again .........................
Hidden
Pad 2
Hidden
Pad 1
70%
50%
DEFROST
Enters into Service Test Mode
Indicates number of magnetron
hours
START
Indicates tube cycles
Indicates number of door cycles
Indicates amperage
Turn dial to Clear Info – When
dial is rotated display indicates
CLEARED INFO
Press Hidden Pad 2 again .........................
Press Hidden Pad 2 again .........................
Press Hidden Pad 2 again .........................
Press Hidden Pad 2 again .........................
©2004 Maytag Services
16023293 Rev. 0
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Testing Procedures
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
!
Illustration
Electronic Control
Component
Keyboard assembly
Testing
Continuity is indicated as
100 Ω and below.
Results
Trace
1 & 8
2 & 8
3 & 8
4 & 8
5 & 8
6 & 8
7 & 8
1& 9
Pad
0
1
2
3
4
5
6
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
RCS10MPA
RCS10SW2A
RFS12SW2A
1
2
3
4
5
6
7
8
9
7
8
9
10
11
2 & 9
3 & 8
1 & 10
HOLD (0%)
DEFROST (20%) 2 & 10 Continuity
MEDIUM (50%)
MED-HI (70%)
TIME ENTRY
STOP/RESET
3 & 10 Continuity
4 & 10 Continuity
5 & 10 Continuity
6 & 10 Continuity
7 & 10 Continuity
START
Electronic Control
Keyboard assembly
Continuity is indicated as
100 Ω and below.
Pad
0
1
2
3
4
5
6
Trace
1 & 8
2 & 8
3 & 8
4 & 8
5 & 8
6 & 8
7 & 8
1& 9
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
RCS10MPSA
RFS12MPSA
1
2
3
4
5
6
7
8
9
7
8
9
10
11
2 & 9
3 & 8
7 & 9
QTY 2X
HOLD (0%)
1 & 10 Continuity
DEFROST (20%) 2 & 10 Continuity
MEDIUM (50%)
MED-HI (70%)
TIME ENTRY
STOP/RESET
3 & 10 Continuity
4 & 10 Continuity
5 & 10 Continuity
6 & 10 Continuity
7 & 10 Continuity
START
Electronic Control
RCS10A
Keyboard assembly
Continuity is indicated as
100 Ω and below.
Pad
0
1
2
3
4
5
6
Trace
1 & 8
2 & 8
3 & 8
4 & 8
5 & 8
6 & 8
7 & 8
1& 9
2 & 9
3 & 8
5 & 10
6 & 10 Continuity
7 & 10 Continuity
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
1
2
3
4
5
6
7
8
9
7
8
9
10
11
TIME ENTRY
STOP/RESET
START
Dial Control
Keyboard assembly
Continuity is indicated as
100 Ω and below.
Pad
Trace
1 & 8
2 & 8
3 & 8
Measurement
30 QUICK SET
HIDDEN #1
HIDDEN #2
Continuity
Continuity
Continuity
RCS10PBDA
1
2
3
4
5
6
7
8
9
DEFROST (20%) 2 & 10 Continuity
MEDIUM (50%)
MED-HI (70%)
TIME ENTRY
STOP/RESET
START
3 & 10 Continuity
4 & 10 Continuity
5 & 10 Continuity
6 & 10 Continuity
7 & 10 Continuity
10
11
22
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Testing Procedures
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
!
RLY 3
2 1
TAB 1
TAB 2
8
3
9
5 4
1
CN1
Function
Test Set-Up /
Condition
Meter
Setting
Probe Placement
Results
Power to current
transformer
Power from current
transformer
All Conditions
Volts
Tab 1 to CN1 Pin 3 (Neutral)
Tab 2 to CN1 Pin 3 (Neutral)
120 VAC
120 VAC
All Conditions
Volts
Power from Oven TCO All Conditions
Power to Oven Light
Volts
CN1 – Pin 1 (Black wire to Neutral)
120 VAC
Standby............. Volts
Ready................ Volts
Cook ................. Volts
CN1 – Pin 4 to Pin 1 ............................. 120 VAC
CN1 – Pin 4 to Pin 1 ............................. 0 VAC
CN1 – Pin 4 to Pin 1 ............................. 0 VAC
CN1 – Pin 5 to Pin 1 ............................. 120 VAC
CN1 – Pin 5 to Pin 1 ............................. 0 VAC
CN1 – Pin 5 to Pin 1 ............................. 0 VAC
CN1 – Pin 8 to Pin 9 ............................. Continuity
CN1 – Pin 8 to Pin 9 ............................. Infinite
Power to Blower Motor Standby............. Volts
Ready................ Volts
Cook ................. Volts
Secondary Interlock
Switch
Door Closed...... Ohms
Door Opened .... Ohms
Power to Relay 3
Standby............. Volts
Ready................ Volts
Cook ................. Volts
Relay 3 – Pin 1 to Pin 2......................... 120 VAC
Relay 3 – Pin 1 to Pin 2......................... 120 VAC
Relay 3 – Pin 1 to Pin 2......................... 0 VAC
©2004 Maytag Services
16023293 Rev. 0
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Testing Procedures
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
!
Power Test
All Amana and Menumaster microwave oven power outputs are rated using the IEC705 standards. Using the IEC705
test method requires precision measurements and equipment that is not practical to be performed in the field. Using
the test shown below will indicate if the oven performance is satisfactory.
Test equipment required:
•
1000 ml test container and thermometer (Amana power test kit R0157397 Fahrenheit / Menumaster power
test kit M95D5 Celsius).
•
Digital watch / watch with a second hand for use on ovens with electromechanical timers.
Important Notes:
•
•
Low line voltage will cause low temperature rise / power output.
Ovens must be on a dedicated circuit, properly grounded, and polarized. Other equipment on the same
circuit may cause a low temperature rise / power output.
•
This test and results are not a true IEC705 test procedures and are only intended to provide servicers with
an easy means of determining if the microwave oven cooking output is correct.
Procedure
1. Fill the test container to the 1000 ml line with cool tap water.
NOTE: Water temperature should be approximately 60°F / 16°C
2. Using the thermometer, stir water for five to ten seconds; measure, and record the temperature (T1).
3. Place test container of water in the center of oven cavity and close door.
4. Heat the water for a 33-second full power cycle.
NOTE: Use a digital watch or a watch with a second hand for ovens with electromechanical timers.
1. At end of the cycle, remove test container. Using the thermometer, stir water for five to ten seconds and record
temperature (T2).
2. Subtract the starting water temperature (T1), from the ending water temperature (T2) to obtain the temperature
rise (?T).
3. If the temperature rise (?T) meets or exceeds the minimum, the test is complete. If the temperature rise (?T)
fails to meet the minimum temperature rise, test the line voltage to verify it is correct. Then repeat steps 1-6
making sure to change the water. If the temperature rise (?T) fails to meet the minimum temperature rise again
the oven will require service.
Minimum Temperature Rise at Thirty -Three (33) Seconds Run Time
?T
Cooking
?T
Cooking
?T
Cooking
?T
Cooking
(°F)
Power Output
(°F)
Power Output
(°C)
Power Output
(°C)
Power Output
10................. 1000
11................. 1100
12................. 1200
14................. 1400
17................. 1700
18................. 1800
19................. 1900
20................. 2000
21................. 2100
22................. 2200
24................. 2400
25................. 2500
27................. 2700
30................. 3000
5 .............. 1000
5.5 ............ 1100
6.5 ............ 1200
7.5 ............ 1400
9.5 ............ 1700
10 ............. 1800
10.5 .......... 1900
11............ 2000
11.5......... 2100
12............ 2200
13............ 2400
13.5......... 2500
15............ 2700
16.5......... 3000
24
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly Procedures
To avoid the risk of electrical shock, personal injury, or death,
disconnectpowertoovenanddischargethecapacitorsbefore
followinganydisassemblyprocedure.
WARNING
!
High voltage is present at the high voltage terminal of the
high voltage transformer during any cooking cycle.
Outer Case
1. Disconnect power to oven.
2. Remove screws securing outer case to unit.
3. Slide outer case towards rear of unit.
4. Reverse procedure to reassemble.
It is neither necessary or advisable to attempt
measurement of the high voltage.
Before touching any oven components or wiring, always
unplug the oven from its power source and discharge
capacitor.
Disconnecting Wire Terminals
All wire terminals are locking-type terminals.
Proceed as follows to disconnect wire terminals:
Insulated terminals:
Grasp insulator pod and pull back.
DO NOT PULL ON WIRE.
1 Grasp
Wire
Insulator
Pull
2
Pod
CAUTION
!
Non-insulated terminals:
Use a small blade screwdriver to depress locking-tab and
pull on terminal.
DO NOT PULL ON WIRE.
During disassembly some foam gaskets may require
removal. These components must be replaced for
proper circulation of air over the components and
through the oven cavity.
Release
locking-tab
1
Wire
2 Pull
©2004 Maytag Services
16023293 Rev. 0
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly Procedures
To avoid the risk of electrical shock, personal injury, or death,
disconnectpowertoovenanddischargethecapacitorsbefore
followinganydisassemblyprocedure.
WARNING
!
Door Assembly
!
Door Disassembly
1. Disconnect power to oven.
2. Remove oven door, (see "Door Removal").
3. Begin at the bottom of the door near hinge, insert flat
blade screwdriver between choke cover and outer door
panel. Gently pry upward on choke cover to release
tabs. Work in clockwise direction to remove choke
cover.
CAUTION
A microwave leakage test must be performed anytime
a door assembly is removed, replaced, disassembled,
or adjusted for any reason.
Door Removal
1. Disconnect power to oven.
2. Open oven door, remove top hinge cap, and slowly lift
door to disengage the hinge pins at top and bottom.
!
CAUTION
To avoid property damage, care must be taken when
prying choke cover from oven door.
Top hinge cap
4. Remove screw securing door handle to latch
assembly.
5. Slide latch assembly downward and pull away from
door frame to release.
6. Remove screws securing choke assembly to outer
door panel.
NOTE: When disassembling door, use caution to
prevent deformation of slats on door frame/choke
assembly.
7. Begin at hinge side of door near bottom, insert flat
blade screwdriver between door frame/choke
assembly and outer door panel. Gently pry outer door
panel away from door frame to release tabs. Work in
clockwise direction to remove door frame.
8. Remove spring from hinge assembly.
9. Remove screws securing hinge assembly to choke
assembly.
3. To reinstall door, place top pin into slot first, then align
bottom pin.
4. Reinstall top hinge cap.
10.Reassemble in reverse order.
Choke
Top
cover
hinge
cap
Outer
Door
panel
Latch
assembly
Spring
Door
Door frame/
Handle
choke assembly
* Tighten side screw first and apply Loctite
26
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly Procedures
To avoid the risk of electrical shock, personal injury, or death,
disconnectpowertoovenanddischargethecapacitorsbefore
followinganydisassemblyprocedure.
WARNING
!
Interlock Switches
!
CAUTION
Primary switch is operated by bottom latch arm.
A microwave leakage test must be performed anytime
a door assembly is removed, replaced, disassembly, or
adjusted for any reason.
Interlock Switch Removal
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Remove control panel, (see "Control Panel" section).
3. Test interlock switches before removing, (see testing
procedures).
4. Disconnect and label wire connections.
5. Remove mounting screws securing interlock switch to
unit chassis.
6. Remove switches by carefully releasing locking tabs
on switch bracket and tilting switches to remove from
switch bracket.
Control Panel Removal
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Disconnect and label wires from controller/timer.
3. Open oven door.
4. Remove screw securing top of control panel to cavity.
Lift control panel up and out to release tabs.
Tab
NC
Monitor
Switch
COM
NO
Primary
Switch
COM
NO
Secondary
Switch
COM
Tab
NOTE: After repairing the door or the interlock system, it
is necessary to check the switch continuity
before operating the oven.
5. Replace component and reverse procedure to
reassemble.
CAUTION
!
Before replacing a blown monitor fuse, test the primary
interlock switch, secondary interlock switch, monitor
switch, and power relay contacts for proper operation.
If the monitor fuse is blown by a failed switch
operation, all switches and controller must be
©2004 Maytag Services
16023293 Rev. 0
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly Procedures
To avoid the risk of electrical shock, personal injury, or death,
disconnectpowertoovenanddischargethecapacitorsbefore
followinganydisassemblyprocedure.
WARNING
!
replaced.
or adjustment of switch bracket is performed.
Adjusting Interlocks
High Voltage Capacitor
The interlock monitor, primary, and secondary switches
act as a final safety switch, protecting the operator from
microwave energy. After adjusting the interlock switch
assembly, verify wires are correctly connected.
High voltage capacitor should always be discharged by
shorting a terminal to a chassis ground. The capacitor
has a internal "shunt" resistor, but the mechanical
discharge should always be performed to avoid personal
injury.
For door fit and switch operation, switch bracket is
adjustable.
High Voltage Capacitor Removal
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Discharge high voltage capacitor.
3. Remove and label wire leads from capacitor terminals.
4. Remove screw securing capacitor strap to bottom
plate.
5. Slide capacitor out of capacitor strap and remove
capacitor.
2. Loosen switch bracket mounting screws.
3. Close oven door, move switch bracket toward rear of
oven until door gap is less than 1/64–inch (0.5 mm).
4. Hold switch bracket securely for proper switch
operation and door fit, retighten screws.
5. Open oven door slowly, watching the switches. Verify
switches release in the following order.
• Primary interlock switch
6. Replace capacitor and reverse procedure to
reassemble.
• Secondary interlock switch
• Interlock monitor switch
NOTE: When replacing H.V. components, route H.V.
wires at least 1/4" / 6 mm from all grounded
surfaces to prevent arcing.
NOTE: Adjust the switch bracket until all switches
operate in proper sequence.
6. Close the oven door slowly, watching the switches.
Verify switches activate in the following order.
• Interlock monitor switch
H.V. Capacitor
Bracket
• Secondary interlock switch
• Primary interlock switch
7. When proper switch sequence has been achieved,
tighten the switch bracket securely.
H.V.
Capacitor
H.V.
Diode
H.V.
Transformer
!
CAUTION
A microwave leakage test must be preformed anytime
a door assembly is removed, replaced, disassembled,
Blower Motor
Assembly
Bottom
Plate
Diode
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Discharge high voltage capacitor, (see "High Voltage
Capacitor" section).
3. Disconnect diode from high voltage capacitor and
remove screw securing diode to ground.
28
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly Procedures
To avoid the risk of electrical shock, personal injury, or death,
disconnectpowertoovenanddischargethecapacitorsbefore
followinganydisassemblyprocedure.
WARNING
!
4. Replace diode and reverse procedure to reassemble.
replaced.
Transformer
Magnetron
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
Magnetron is located on the side of the cavity.
1. Disconnect power to oven and remove outer case,
(see "Outer Case" section).
2. Discharge high voltage capacitor, (see "High Voltage
Capacitor" section).
3. Remove terminal plug from filament terminals.
4. Remove screws securing magnetron cutout bracket to
magnetron.
2. Discharge high voltage capacitor, (see "High Voltage
Capacitor" section).
3. Disconnect and label wire leads from transformer.
4. Remove screws securing transformer and remove.
5. Replace transformer and reverse procedure to
reassemble.
5. Remove screws securing magnetron to the wave
guide.
Fuse / Fuse Block / Filter Assembly
1. Disconnect power to oven and remove outer case,
(see "Outer Case" section).
2. Disconnect and label wires.
3. Remove fuses to gain access to screws securing
assembly.
Antenna
Gasket
Chassis
4. Carefully lift tab to release assembly from locating
pin.
5. Replace component(s) and reverse procedure to
reassemble.
Filament
!
CAUTION
6. Replace magnetron and reverse procedure to
reassemble.
Before replacing a blown monitor fuse, test the primary
interlock switch, secondary interlock switch, monitor
switch, and power relay contacts for proper operation.
If the monitor fuse is blown by a failed switch
NOTE: When replacing magnetron, make sure gasket is
in correct position and in good condition.
operation, all switches and controller must be
CAUTION
During replacement of magnetron, be certain the R.F.
anode gasket is in place around the anode stud.
!
WARNING
!
A microwave leakage test must be performed anytime
a magnetron assembly is removed, replaced,
disassembled, or adjusted for any reason.
©2004 Maytag Services
16023293 Rev. 0
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly Procedures
To avoid the risk of electrical shock, personal injury, or death,
disconnectpowertoovenanddischargethecapacitorsbefore
followinganydisassemblyprocedure.
WARNING
!
Blower Motor or Wheel
Splatter Shield
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
NOTE: Be careful not to bend antenna when removing
splatter shield. Shield snaps into a lip in front of
the oven and three slots in the back.
2. Remove outer case.
3. Disconnect wiring from blower motor.
4. Remove screws securing scroll to chassis.
5. Slide scroll discharge snout from partition and lift
scroll assembly from unit.
6. Replace component and reverse procedure to
reassemble.
1. Place your thumbs in the two indentations in front of
the shield.
2. Press lightly towards the back and carefully lower
shield away from antenna.
3. Pull shield out of the back slots and out of the oven.
Splatter
shield
Antenna
1. Remove splatter shield from oven cavity.
2. Remove two mounting rivets on the top of oven cavity
to remove cradle. Support cradle before removing
mounting rivets to avoid damage to antenna
assembly.
Stirrer Motor
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Remove outer case.
3. Disconnect wire terminal s from stirrer motor.
4. Remove screws securing stirrer motor to wave guide.
5. Replace component and and reverse procedure to
reassemble.
NOTE: When replacing stirrer motor, verify motor shaft is
aligned with antenna shaft before securing with
screws.
30
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Disassembly Procedures
To avoid the risk of electrical shock, personal injury, or death,
disconnectpowertoovenanddischargethecapacitorsbefore
followinganydisassemblyprocedure.
WARNING
!
Magnetron Thermal Cut-Out (TCO)
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Remove outer case.
3. Remove TCO by removing screws.
4. Disconnect wiring.
Oven Light Removal
The light bulb for inside of the oven can be changed only
from the side of the unit. On the left hand side of the oven
is a metal plate with one screw. The light bulb is located
behind this plate.
Follow these steps to change the bulb:
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Remove screw and plate from side of unit.
3. To remove bulb, turn it counterclockwise, being
careful not to burn fingers or break the bulb.
4. Replace bulb with a 40 watt, 115 - 125 volt appliance
bulb.
5. Replace component and reverse procedure to
reassemble.
NOTE: When reconnecting wiring to thermal fuses the
connectors must be tight.
Cavity Thermal Fuse
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Remove outer case.
3. Remove thermal fuse mounting screw.
4. Disconnect wiring.
5. Reposition plate, being careful not to bend hinge tab.
Replace and tighten screw. Do not operate oven
without plate in place.
5. Replace component and reverse procedure to
reassemble.
NOTE: When reconnecting wiring to thermal fuses the
connectors must be tight.
Tray Replacement
1. Unplug oven from outlet.
2. Using a suction cup to pry upward on front portion and
remove tray from unit.
3. Thoroughly clean and degrease sump area.
4. Clean oven cavity bottom where new oven tray will
make contact using mineral spirits or any
non-flammable degreasing solvent.
NOTE: Detergents, soap, and water are not sufficient to
remove oil and grease.
5. Place new tray into unit and clean cavity with mild
detergent to remove any remaining degreasing
solvant.
©2004 Maytag Services
16023293 Rev. 0
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
©2004 Maytag Services
16023293 Rev. 0
A–1
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Start Reference Guide
Refer to Product Safety Manual for Safety Statements
Complete Owner’s Manual available online
Oven Wall Clearances
A—For North American (UL/CSA) models,
allow at least 2” (5.1 cm) of clearance
The switching operation of this
microwave oven can cause voltage
fluctuations on the supply line. The
operation of this oven under
around top of oven. For International (50 Hz)
models, allow at least 12” (30 cm) of
clearance around top of oven. Proper air
flow around oven cools electrical
components. With restricted air flow, oven
may not operate properly and life of
electrical parts is reduced.
A
B
unfavorable voltage supply conditions
can have adverse effects. This device
is intended for the connection to a
power supply system with a maximum
permissible system impedance Zmax
of 0.2 Ohms at the interface point of
the user’s supply. The user has to
ensure that this device is connected
only to a power supply system which
fulfills the requirement above. If
C
B—Allow at least 2” (5.1 cm) between air
discharge on back of oven and back wall.
C—Allow at least 2” (5.1 cm) of clearance
around sides of oven.
necessary, the user can ask the public
power supply company for the system
impedance at the interface point.
DO NOT power spray
No metal pans
So...how do I use it?
(Mechanical Dial)
Heating
1. Open oven door, place food in oven, and close oven door.
2. Turn time entry knob clockwise to desired time.
• Cooking time can be set up to 6 minutes.
• Oven begins operation and time counts down.
3. When cooking time has elapsed, microwave energy stops and oven
signal sounds.
Interrupting Operation
Open oven door to interrupt operation or turn time entry knob
counterclockwise to “0”.
To resume microwave oven operation, close door and turn knob.
Changing Time and Canceling Mistakes
Heating time can be changed at any time while the oven is operating. Turn
knob to desired new setting. To set cooking time to zero, turn knob
counterclockwise to “0”.
For full product documentation visit:
© 2004 Amana Appliances
Part No.12804404
Revised 10/04
™
Amana, Iowa 52204
A–2
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Start Reference Guide
Refer to Product Safety Manual for Safety Statements
Complete Owner’s Manual available online
So...how do I use it? (Digital Dial)
Heating
1. Open oven door, place food in oven,
and close oven door.
2. Turn time entry knob clockwise until
desired time displays.
:30 QUICK SET Pad
Allows you to reheat for 30 seconds at 100% (full) power by simply pressing the
:30 QUICK SET pad. By repeatedly pressing this pad, you can extend the reheating time to 5
minutes by 30 second increments. To change the time assigned to this pad:
1. Open oven door.
If door is closed before programming is
complete, changes are discarded.
2. Press and hold the :30 QUICK SET pad
for approximately 5 seconds.
current or assigned time will show in
display.
•
Factory default setting for cooking
time is 10 minutes. Cooking time can
be changed and set to 60 minutes.
(Refer to section on changing
options)
•
3. Turn Dial to change time setting.
• Time can be set from zero (0:00)
seconds to five minutes (5:00).
• If the assigned time is 0:00, the :30
QUICK SET pad is effectively
disabled.
•
This activates the programming
mode.
Microwave will beep and either
3. Press a power level pad to change
power level, if desired. If no power level
is selected, unit will default to 100%.
•
4. Press START pad to save changes.
•
Power level can be set from full
power (100%), to 70%, 50% or
DEFROST (20%).
Can I change an option?
Options can be changed to suit individual preferences.
4. Press START button.
Oven begins operation and time
counts down.
•
?
To change options:
3. Press the Hidden Pad to advance to
the desired option to be changed.
See table below for options.
4. Turn Dial to change option setting.
1. Open oven door.
5. When cooking time has elapsed,
microwave energy stops and oven
signal sounds.
• If door is closed before programming is
complete, changes are discarded and
microwave exits options programming
mode.
•
•
•
0P: and option number appear in
display.
See table below for options.
2. Press and hold the Hidden Pad for
approximately 5 seconds.
• This begins options programming
mode.
Interrupting Operation
Open oven door to interrupt operation or turn
time entry knob counterclockwise to “0”.
5. Press START pad to save changes.
•
To change additional options, repeat
steps 2 - 5.
Changes appear after door is
closed.
To resume microwave oven operation, close
door and press START .
If time was changed to “0”, time will need to be
reset, and then press START.
• Microwave will beep and 0P:--
appears in display.
•
Numbered Pads
Display
Options (Factory Settings in Bold)
Changing Time and
Power/Canceling
Mistakes
Heating time and power level can be changed
at any time while the oven is operating. Turn
knob to desired new setting. To set cooking
time to zero, turn knob counterclockwise to
“0”.
1
OP:10
OP:11
OP:12
OP:20
OP:21
OP:22
OP:23
OP:30
OP:31
3 second continuous beep.
Continuous beep until door is opened.
5 beep bursts until door is opened.
Eliminates beep.
End of Cycle Beep
2
Speaker Volume
Sets volume to low.
Sets volume to medium.
Sets volume to high.
3
Key Beep
4
Prevents beep when pad is pressed.
Allows beep when pad is pressed.
OP:40
OP:41
OP:42
15 seconds after oven door is opened, keyboard disabled.
30 seconds after oven door is opened, keyboard disabled.
Keyboard Enable
Window
1 minute after oven door is opened, keyboard
disabled.
2 minutes after oven door is opened, keyboard disabled.
Prevents adding heating time while oven is heating.
OP:43
OP:50
OP:51
5
Add Time During
Heating
Allows heating time to be changed while oven is
heating when a memory pad is pressed.
6
OP:60
Allows oven to resume heating time countdown after door
is opened during cycle.
Reset Door Open
Cancels heating time count down after door is opened
during cycle.
OP:61
7
OP:70
Allows 60 minutes of heating time.
Hidden
Pad
(some models)
OP:71
Allows 10 minutes of heating time.
Maximum Heating Time
0
OP:00
OP:01
OP:02
OP:03
Do not display message.
Clean Filter Message
Display message for 24 hours every 7 days.
Display message for 24 hours every 30 days.
Display message for 24 hours every 90 days.
For full product documentation visit:
16023293 Rev. 0
© 2004 Amana Appliances
Part No.12804404
Revised 10/04
™
Amana, Iowa 52204
©2004 Maytag Services
A–3
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Start Reference Guide
Refer to Product Safety Manual for Safety Statements
Complete Owner’s Manual available online
CLEAN FILTER
This oven displays CLEAN FILTER at user
defined intervals. When the message
displays Amana recommends cleaning
the air filter thoroughly. Cleaning the air
filter will not shut off the message.
The message will stop displaying
Oven Wall Clearances
A—For North American (UL/CSA) models, allow at least
2” (5.1 cm) of clearance around top of oven. For
International (50 Hz) models, allow at least 12” (30
cm) of clearance around top of oven. Proper air flow
around oven cools electrical components. With
restricted air flow, oven may not operate properly
and life of electrical parts is reduced.
A
B
C
automatically after 24 hours. Depending
on microwave use and environmental
conditions, the filter may need to be
cleaned more frequently. Once the
frequency is determined, set the option
for the appropriate time frame.
B—Allow at least 2” (5.1 cm) between air discharge on
back of oven and back wall.
C—Allow at least 2” (5.1 cm) of clearance around sides
of oven.
So...how do I use it?
Manual Operation
(Electronic Control)
Preprogrammed
Pads
7
To cook food using a specific entered time and power level:
To cook food using preprogrammed
cooking sequences:
1. Open oven door and place food in oven. Close door.
2. Press TIME ENTRY pad and enter cooking time.
3. Press a power level pad to change power level if desired (some
models).
1. Open oven door and place food
in oven. Close door.
• COOK LEVEL displays with the power setting.
4. If stage cooking is desired, press TIME ENTRY pad and repeat steps
2 through 4, (some models).
2. Press desired pad.
3. Oven begins to cook.
4. At end of cooking cycle oven
beeps and shuts off.
5. Press START pad.
6. At end of cooking cycle oven beeps and shuts off.
Programming Items
1. Open oven door.
2. Press and hold pad 1 for approximately 5 seconds.
3. Press pad to be reprogrammed.
4. Enter cooking time by using the number pads.
5. Press a power level pad to change power level if desired.
6. If stage cooking is desired, press TIME ENTRY pad.
• Display briefly shows the stage number.
• Display changes to cook time and power level for the next stage.
7. Enter cook time and power level as in steps 4 and 5 (some models).
• To enter another cooking stage for that pad, press TIME ENTRY pad
again.
• Up to four different stages can be programmed (some models).
8. Press START pad to set new programming changes to the pad.
QTY 2X
Programming
(some models)
QTY
2X
To change the cooking factor:
1. Open oven door.
2. Press and hold pad 1 for
approximately 5 seconds.
3. Press pad to be reprogrammed.
4. Press the QTY 2X pad.
5. Press a numbered pad to
change the cooking factor.
• Cooking factor can be set
from 10% to 100%.
NOTE: To discard changes, press STOP/RESET pad or close oven door.
• Default is 80%.
• Pad 5 would change the
cooking factor to 50%.
6. Press START pad to save
changes.
QTY 2X Pad (some models)
1. Open oven door and place food in oven. Close door.
2. Press QTY 2X pad.
3. Press desired preprogrammed pad or pad sequence.
4. Oven begins cooking. Displayed cooking time is the total of original
cooking time and added 2X time.
The switching operation of this microwave oven can cause voltage fluctuations on the supply line. The operation of this oven under
unfavorable voltage supply conditions can have adverse effects. This device is intended for the connection to a power supply system
with a maximum permissible system impedance Zmax of 0.2 Ohms at the interface point of the user’s supply. The user has to ensure
that this device is connected only to a power supply system which fulfills the requirement above. If necessary, the user can ask the
public power supply company for the system impedance at the interface point.
A–4
16023293 Rev. 0
©2004 Maytag Services
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Start Reference Guide
Refer to Product Safety Manual for Safety Statements
Complete Owner’s Manual available online
Can I change an option?
Options such as single or double pad programming, beep volume, and
maximum cooking time can be changed to suit individual preferences.
?
To change options:
1. Open oven door.
• If door is closed or RESET pad is pressed before programming is complete,
changes are discarded and microwave exits programming mode.
2. Press and hold pad 2 for approximately 5 seconds.
• This begins options mode.
DO NOT power spray
• Microwave will beep and 0P: displays.
3. Press number pad that controls option to be changed.
• See table below for options.
• Current option will display.
4. Press number pad again to change the option.
• Each time pad is pressed, option will change.
• Match code displayed with code for desired option.
5. Press START pad to save changes.
No metal pans
Numbered Pads
• To change additional options, repeat steps 3 and 4.
• Changes appear after door is closed or STOP/RESET pad is pressed.
Display
Options (Factory Settings in Bold)
1
OP:10
OP:11
OP:12
OP:20
OP:21
OP:22
OP:23
OP:30
OP:31
OP:40
OP:41
OP:42
OP:43
OP:50
OP:51
3 second beep.
End of Cycle Beep
Continuous beep until door is opened.
5 beep bursts until door is opened.
Eliminates beep.
2
Speaker Volume
Sets volume to low.
Sets volume to medium.
Sets volume to high.
3
Key Beep
4
Prevents beep when pad is pressed.
Allows beep when pad is pressed.
15 seconds after oven door is opened, keyboard disabled.
30 seconds after oven door is opened, keyboard disabled.
1 minute after oven door is opened, keyboard disabled.
2 minutes after oven door is opened, keyboard disabled.
Prevents adding heating time while oven is heating.
Keyboard Enable
Window
5
Add Time During
Heating
Allows heating time to be changed while oven is heating when a memory pad
is pressed.
6
OP:60
Allows oven to resume heating time countdown after door is opened during
cycle.
Reset Door Open
OP:61
OP:70
OP:71
Cancels heating time count down after door is opened during cycle.
Allows 60 minutes of heating time (some models).
Allows 10 minutes of heating time.
7
(some models)
Maximum Heating Time
8
Manual Operation
9
OP:80
OP:81
OP:90
OP:91
Allows use of preprogrammed pads only.
Allows use of manual time entry and preprogrammed pads.
Allows 10 (0-9) preprogrammed pads.
(some models)
Double Digit Operation
0
Allows 100 (00-99) preprogrammed pads.
OP:00
OP:01
OP:02
OP:03
Do not display message.
Clean Filter Message
Display message for 24 hours every 7 days.
Display message for 24 hours every 30 days.
Display message for 24 hours every 90 days.
For full product documentation visit:
© 2004 Amana Appliances
Part No.12804405
Revised 10/04
™
Amana, Iowa 52204
©2004 Maytag Services
16023293 Rev. 0
A–5