OWNER’S MANUAL  
VMH 09/12/18/24  
Version C  
Inverter Single Zone  
Ductless Mini-Split Heat Pump  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller, Inc.  
OWNER’S MANUAL  
VMH Inverter Mini-Split  
To prevent injury to the user, other people and/or to property, the following instructions must be followed. Incorrect operation  
due to ignoring these instructions may cause harm or damage. The seriousness is classified by the following indications:  
This symbol indicates the possibility of death or serious injury.  
This symbol indicates the possibility of injury or damage to property.  
WARNING!  
CAUTION!  
!
!
Meanings of symbols used in this manual are as shown below:  
Never do this.  
Always do this.  
!
• Do not attempt to install this air conditioner by yourself.  
WARNING!  
!
!
• This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs.  
• Do not insert fingers or objects into the outlet or intake grilles.  
• Do not start and stop air conditioner operation by disconnecting the power supply.  
Take care not to damage the power supply wiring.  
• In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the  
power supply, and consult authorized service personnel.  
• Provide occasional ventilation during use.  
CAUTION!  
• Do not direct air flow at fireplaces or heating apparatus.  
• Avoid installing the air conditioner near a fireplace or other heating apparatus.  
• Do not climb on, or place objects on, the air conditioner.  
• Do not hang objects from the indoor unit.  
• Do not set flower vases or water containers on top of the air conditioner.  
• Do not expose the air conditioner directly to water.  
• Do not operate the air conditioner with wet hands.  
• Turn off power source when not using the unit for extended periods.  
• Do not drink the water drained from the air conditioner.  
• Connection valves become hot during Heating; handle with care.  
• Do not apply any heavy pressure to evaporator fins.  
• Operate only with air filters installed.  
• Do not block or cover the intake or outlet grille.  
• Ensure that any electronic equipment is at least 3 feet (1m) away from either the indoor or outdoor  
units.  
• Do not use inflammable gases near the air conditioner.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
VMH Inverter Mini-Split  
OWNER’S MANUAL  
Heat Controller, Inc.  
Identification of Parts  
Base valve  
(Heat Pump  
mode.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller, Inc.  
OWNER’S MANUAL  
VMH Inverter Mini-Split  
Displayed when TURBO function is selected in  
cooling or in heating modes. This air conditioner  
is equipped with an ionizer, which generates  
ions to remove microscopic particles from the air.  
Rooms become healthier for those suffering from  
asthma or allergies with the use of this feature.  
This display is separated into five zones.  
The zones illuminate base on the com-  
pressor’s current frequency. For ex-  
ample, a higher frequency will illuminate  
more zones.  
TURBO operation display  
Illuminated when TURBO function is selected in  
cooling or heating operation.  
DIGITAL DISPLAY  
Displays the current set temperature when the air  
conditioner is in operation. When SELF CLEAN  
feature is activated, its displays “SC”.  
Remote Controller Features  
The remote controller comes with a FOLLOW ME feature which allows the remote controller to act as a  
thermostat. This allows the unit to sense the temperature at the location of the remote controller, rather  
than sensing the temperature at the indoor unit. The indoor unit is installed high on a wall, thus the ther-  
mostat on the remote controller will provide a more accurate temperature reading for the room. Consult  
the remote controller manual for more information.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
VMH Inverter Mini-Split  
OWNER’S MANUAL  
Heat Controller, Inc.  
NOTE: This manual does not include Remote Controller Operations, see the <<Remote Controller Manual>>  
packaged with the unit for details.  
See chart below for operating conditions:  
Ambient Operating Conditions  
Mode  
Temp  
Fahrenheit  
5 to 122  
=62.6  
Celsius  
-15 to 50  
=17  
Outdoor  
Indoor  
Cooling  
Outdoor  
Indoor  
5 to 93.2  
=86  
-15 to 34  
=30  
Heating  
Outdoor  
Indoor  
5 to 122  
>50  
-5 to 50  
>10  
Dehumidification  
Operating Conditions:  
When cooling is needed year round, including when outdoor temperatures are apt to fall below freezing, our  
V Series inverter driven ductless mini-split systems will continue to work, as they come with factory installed  
low ambient controls. The low ambient feature works by regulating the head pressure by varying the amount of  
air flow through the condenser, which helps to prevent evaporator freeze ups and low pressure problems due to  
low ambient outdoor temperatures. Low ambient operation is a great feature for temperature/humidity sensitive  
environments or applications such as server/computer rooms, supermarkets, restaurants, or cooling tower fans.  
Additionally, a crank case heater is required and factory installed, as it is needed for use with the low ambient  
controls. The crank case heater minimizes liquid refrigerant migration to the compressor when the compressor  
is not operating and helps to keep the compressor oil warm enough so that it remains fluid to prevent slugging.  
Crank case heaters also assist to greatly reduce heat loss to ambient air. Together, the lower ambient feature  
combined with the factory installed crank case heater, will not only allow the air conditioner to cool year round,  
but will also prevent compressor failure in low ambient conditions.  
Manual Operation:  
Manual operation can be used temporarily to run the unit without using the remote controller. This feature can  
also be used to test the unit during installation and troubleshooting by an authorized service technician.  
NOTE: The unit must be turned off before operating the  
manual control button. If the unit operational, continue press-  
ing the manual control button until the unit is off.  
1. Grasp both sides of the panel and pull it down. The panel  
opens upward to an angle of 15°. Push the panel upward  
and then lift it up.  
2. One press of the manual control button will lead to the  
forced AUTO operation. If the button is pressed twice  
within five seconds, the unit will operate under forced  
COOL operation. Press the button a third time to stop the  
manual operation.  
3. Close the panel firmly to its original position.  
CAUTION:  
• This button is used for testing purposes only.  
To restore the remote controller to control the unit, siply  
begin to operate the unit with the remote controller.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller, Inc.  
OWNER’S MANUAL  
VMH Inverter Mini-Split  
NOTE: The remote controller provided with your unit  
may differ in appearance. Please refer to the <<Remote  
Controller Manual>> supplied with the unit to operate the  
unit properly.  
• Adjust the air flow direction properly otherwise it might  
cause discomfort or uneven room temperatures.  
• Adjust the horizontal louver using the remote controller.  
• Adjust the vertical louver manually.  
To set the vertical (up-down) air flow direction  
Perform this function while the unit is in operation. Press  
the SWING button on the remote controller to move the  
louver to the desired direction. The angle of the horizon-  
tal louver moves 6° for each press of the button.  
To set the horizontal (left-right) air flow direction  
Adjust the vertical louver manually using the lever on  
the left or right side of the vertical louver arm (depending  
on model). Take care not to catch fingers on the fan,  
horizontal louver or to damage vertical louvers. Move the  
lever to the desired position to direct air flow.  
Hold the SWING button without releasing it for more than  
2 seconds. The horizontal louver will swing up and down  
automatically.  
To stop the function, press the SWING button again.  
The swing function will be disabled when the air conditioner is not in  
operation (including when the TIMER ON is set).  
button  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
VMH Inverter Mini-Split  
OWNER’S MANUAL  
Heat Controller, Inc.  
OPERATING MODES  
AUTO operation  
• When you set the air conditioner to AUTO mode, it will automatically select  
cooling, heating (heat pump models only), or fan only operation depending  
on what temperature you have selected and the actual room temperature.  
• The air conditioner will control room temperature automatically around  
the temperature set point you select.  
• If the AUTO mode is uncomfortable, you can change desired tempera-  
ture settings manually.  
ECONOMY/SLEEP operation  
• When you push ECONOMY button on remote controller it activates  
SLEEP mode. During cooling, heating (heat pump only), or AUTO op-  
eration, the air conditioner will automatically increase (cooling) or de-  
crease (heating) 2°F (1°C) per hour.  
2°F  
2°F  
• The set temperature will become steady 2 hours later.  
• The SLEEP mode will turn off after 7 hours and revert back to the previ-  
ous settings.  
• The fan speed will be automatically controlled.  
• This feature can maintain the most comfortable temperature and save  
more energy during use.  
2°F  
2°F  
DRY MODE/DEHUMIDIFYING operation:  
• The temperature is regulated while dehumidifying by repeatedly turning  
on and off of the cooling operation or fan only. The fan speed will be au-  
tomatically controlled. In this mode, if the room temperature is lower than  
50°F (10°C) the compressor will stop. The compressor will restart when  
the room temperature is above 54°F (12.2°C).  
Optimal Usage Tips:  
To achieve optimal performance, please note the following:  
• Adjust the air flow direction correctly so that it is not directed directly  
blowing on people/animals.  
• Adjust the temperature to achieve the highest comfort level. Do not ad-  
just the unit to excessive temperature levels.  
• When in COOL or HEAT modes close any open doors and windows within  
the room that the unit is operating in to increase performance.  
• Use TIMER ON button on the remote controller to select a time you want  
to start your air conditioner.  
• Do not put any objects near air inlet or air outlet, as the efficiency of the  
air conditioner may be reduced and the air conditioner may stop running  
due to air flow blockages.  
• Clean the air filter periodically, otherwise performance may be reduced.  
• Do not operate unit with louvers in a closed position  
• SUGGESTION: For units with an electric heater, when the outside  
ambient temperature is below 32°F (0°C), we strongly recommend that  
you keep the unit powered on in order to guarantee it runs smoothly.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller, Inc.  
OWNER’S MANUAL  
VMH Inverter Mini-Split  
NOTE: Supply power must be disconnected before  
cleaning the indoor unit.  
Do not use an overly wet cloth to clean the unit as  
it may damage the electronic components. A damp  
cloth can be used if needed.  
Never use water hotter than 104°F (40°C) to clean the  
front panel. It could cause deformation or discoloration.  
Cleaning the air filter  
NOTE: Supply power must be disconnected before  
cleaning the indoor unit.  
Hold the handle of the air filter and lift it up slightly  
to take it out from the filter holder, then pull it  
downwards.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
VMH Inverter Mini-Split  
OWNER’S MANUAL  
Heat Controller, Inc.  
CARE AND MAINTENANCE  
3. Remove the AIR FILTER from the indoor unit.  
• Clean the AIR FILTER once every two weeks.  
• Clean the AIR FILTER with a vacuum cleaner or with water,  
then dry it in a cool place  
4. Remove the Air Freshening Filter (optional filters: plasma dust col-  
lector/silver ion filter/bio filter/vitamin C filter) from it support frame.  
The installation and removing method of the air freshening filter is  
different depending on the models. See the pictures marked 1 and  
2 on the left.  
• Clean the air freshening filter at least once a month, and re-  
place it every 4-5 months.  
• Clean it with a vacuum cleaner, then dry it in a cool place.  
5. Install the air freshening filter back into position.  
6. Insert the upper portion of the air filter back into the unit taking care  
that the left and right edges line up correctly when placing filter into  
position.  
Maintenance  
If you do not plan on use the unit for a long period of time:  
1. Clean the indoor unit and air filter.  
2. Select FAN only mode, let the indoor fan run for a while to dry the  
inside of the unit.  
3. Disconnect the power supply and remove the batteries from the remote  
controller.  
4. Check components of the outdoor unit periodically. Contact a local  
dealer or an authorized servicer if the unit requires servicing.  
NOTE: Before you clean the air conditioner, be sure to switch the unit  
off and disconnect the power supply.  
When the air conditioner is to be used again:  
• Use a dry cloth to wipe off the dust accumulated on rear air intake grille  
in order to avoid the dust blowing out from the outdoor unit.  
• Check that the wiring is not broken off or disconnected.  
• Check that the air filter is installed.  
• Check if the air outlet or inlet is blocked after the air conditioner has not  
been used for a long time.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller, Inc.  
OWNER’S MANUAL  
VMH Inverter Mini-Split  
Typical Operational Occurrences  
The following events may occur during normal operation.  
1. Protection of the air conditioner.  
Compressor protection  
• If the unit is stopped and then immediately restarted again, the compressor will not operate for  
about 3 minutes in order to protect the compressor.  
Anti-cold air (heat pump models only)  
• The unit is designed not to blow cold air in HEAT mode, when the indoor heat exchanger is in one  
of the following three situations and the set temperature has not been reached.  
A) When heating has just starting.  
B) Defrosting is occurring  
C) Low temperature heating is occurring  
Defrosting (Cooling and heating models only)  
• The indoor or outdoor fan stop running when defrosting (heat pump models only).  
• Frost may accumulate on the outdoor unit during heat cycle when outdoor temperature is low and  
humidity is high, resulting in lower heating efficiency of the air conditioner.  
• During this condition, air conditioner will stop the heating operation and start defrosting automatically.  
• Defrost time may vary from 4 to 10 minutes according to the outdoor temperature and the amount of  
frost buildup on the outdoor unit.  
2. Mist or steam are being emitted  
• A white mist may emit from the indoor unit due to a large temperature difference between air inlet  
and air outlet in COOL mode in an indoor environment that has a high relative humidity.  
• A white mist may emit due to moisture generated from the defrosting process when the air condi-  
tioner restarts in HEAT mode operation after defrosting.  
3. Typical sounds  
You may hear a low hissing sound when the compressor is running or has just stopped running. This  
sound is the sound of the refrigerant flowing or coming to a stop.  
You can also hear a low “squeak” sound when the compressor is running or has just stopped run-  
ning. This is caused by heat expansion and cold contraction of the plastic parts in the unit when the  
temperature is changing.  
• A noise may be heard due to louver restoring its original position when power is first turned on.  
• A sizzling sound may be heard occasionally when the unit is defrosting.  
4. Dust is blown out from the indoor unit  
• This is a normal condition when the air conditioner has not been used for a long time or during first  
use of the unit and an accumulation of dust has formed on the unit’s outlet. Cleaning dust off of the  
unit before operation will prevent this.  
5. A peculiar smell comes out from the indoor unit  
• This is caused by the indoor unit giving off smells permeated from building material, from furniture,  
or smoke. A burning smell could mean there is something wrong with the unit. Power off the unit and  
call an authorized servicer.  
6. Operating mode changes to FAN ONLY mode  
• When the indoor temperature reaches the temperature set point on air conditioner, the compressor  
will stop automatically, and the air conditioner mode changes to FAN only mode. The compressor  
will start again when the indoor temperature rises above the set point in the COOL mode or falls  
below the set point in the HEAT mode (heat pump only models).  
7. Condensation  
• Dripping water may generate on the surface of the indoor unit when cooling in relatively high humid-  
ity. Adjust the vertical louver to the maximum air outlet position and select HIGH fan speed. NOTE:  
Water could drop onto the floor or objects below the indoor unit.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VMH Inverter Mini-Split  
OWNER’S MANUAL  
Heat Controller, Inc.  
8. Heating mode (heat pump models only)  
• The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit dur-  
ing heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner  
decreases accordingly. At the same time, the heat load of the air conditioner increases due to  
larger difference between indoor and outdoor temperature. If a comfortable temperature can’t be  
achieved by the air conditioner, we suggest you use a supplementary heating device.  
9. Auto-restart function  
• Power failure during operation will stop the unit completely.  
• For units with the Auto-restart feature, when the power restores, the unit restarts automatically us-  
ing the previous settings preserved by the memory function of the unit. Timer settings may need  
to be adjusted after a power failure.  
10. Electrical interference  
• Electronic equipment which uses wireless radio transmitters within 3 ft (1m) of the air condition-  
ing unit may cause the unit to malfunction. Disconnect the unit with power and then re-connect  
the unit with power again. Push the ON/OFF button on the remote controller to restart operation.  
Ensure that the air conditioner unit is as far away from any electronic interference sources as pos-  
sible, otherwise wireless interference can occur.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller, Inc.  
OWNER’S MANUAL  
VMH Inverter Mini-Split  
Troubleshooting Tips  
Stop the air conditioner immediately if one of the following errors occurs. Disconnect the power and contact  
an authorized servicer.  
If any of the following error codes appear on the LED window, disconnect the power and contact  
an authorized servicer: E0, E1, E2, E3, E4, E5, E6, E7, E8, P0, P1, P2, P3, P4.  
Call for  
Fuse blows or circuit breaker trips frequently  
service if  
Other abnormal situations (such as burning smells) that can’t be resolved using the steps outlined  
below.  
Symptoms Possible Cause/Things to Check  
What should be done?  
Wait for the power to be restored or call an  
electrician to address any power supply problem.  
Is there power supplied to the unit?  
Fuse may have blown out or a circuit  
Unit does  
no start or  
Replace the fuse or flip the circuit breaker.  
breaker has been tripped.  
operate at  
all  
Batteries in remote controller may be dead Replace the batteries and ensure the polarities  
or installed incorrectly.  
are correct.  
Is the unit’s timer set?  
Wait or cancel timer setting.  
Inappropriate temperature setting.  
Set temperature correctly.  
Air filter may be blocked  
Clean the air filter to prevent air flow blockages.  
Poor cooling  
or heating  
Close the doors or windows within the area  
being cooled/heated to increase efficiency and  
performance.  
(heat pump Doors or windows are open.  
models only)  
performance  
Air inlet or outlet of indoor or outdoor unit  
are blocked.  
Clear obstructions away, then restart the unit.  
Wait approximately 3 minutes for the compressor  
to turn on and the unit to begin cooling/heating.  
Compressor time delay has been activated  
If the problem persists after performing these checks, or if you notice burning smells, or the operation  
indicator light flashes repeatedly, immediately stop operation, disconnect the power, and call an authorized  
service center.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
09/2010  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Portable Radio WD 2511U User Manual
LG Electronics Cell Phone UX390 User Manual
Linn Turntable BASIK User Manual
LOREX Technology Security Camera SG7520 User Manual
Lux Products Electric Heater LV1 User Manual
Matsushita Laptop CF 29N3LGZBM User Manual
Maxon Telecom Car Stereo System SM 2000 User Manual
Maytag Washer W10270227 User Manual
Meade Telescope NG User Manual
Melissa Vacuum Cleaner 740 095 User Manual