27" Electric Dryer
OVERALL DIMENSIONS
PRODUCT MODEL NUMBERS
MEDX500X, MEDX550X,
MEDX600X
Dryer dimensions
23¾"
Electrical: This dryer requires a 3 or 4 wire, single
phase, 120/240 volt, 60 Hz., AC only electrical
supply (or 3 or 4 wire, 120/208 volt electrical supply,
if specified on the serial/rating plate) on a separate
30-amp circuit, fused on both sides of the line. A time-
delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
(603 mm)
43"
43"
(1092 mm)
(1092 mm)
13¾"
(349 mm)
*291/2"
*291/2"
(749 mm)
(749 mm)
27"
27"
(687 mm)
Exhaust venting: Exhaust your dryer to the outside.
4" (102 mm) diameter vent is required. Rigid or flexible
metal exhaust vent must be used. Do not use plastic
or metal foil vent. Exhaust hood must be at least
12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
(687 mm)
A
B
A. Large opening side-swing door
B. Wide opening hamper door
*Most intallations require a minimum 5 1/ " (140 mm) clearance behind the dryer for
the exhaust vent with elbow. See "Venting Requirements" in the Use and Care Guide.
2
Exhaust hood styles:
B
4"
C
Minimum required spacing
(102 mm)
A
For cabinet installation, with a door, the minimum ventilation openings in the top are
required.
4"
2½"
(64 mm)
(102 mm)
3"*
(76 mm)
4"
14" max.*
(356 mm)
2
(102 mm)
48 in.
*
Recommended styles:
A. Louvered hood
B. Box hood
Acceptable styles:
C. Angled hood
(310 cm )2
18"*
(457 mm)
Vent System Chart:
2
Number 90º Type of vent
elbows
Box /louvered
hoods
Angled
hoods
*
24 in.
(155 cm )
3"*
2
(76 mm)
0
1
2
3
4
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
27"
1"
(25 mm)
1"*
1"
29 ¼"
5 ½"*
(686 mm)
(25 mm)
(25 mm)
(743 mm) (140 mm)
B
C
A
A. Recessed area
C. Closet door with vents
*Additional spacing recommended
NOTE: Side and bottom exhaust installations have a 90°
turn inside the dryer. To determine maximum exhaust length,
add one 90° turn to the chart.
For closet installation, with a door, the minimum ventilation openings in the top
and bottom of the door are required. Louvered doors with equivalent air ventilation
openings are acceptable.
Select the route that will provide the straightest and most
direct path outdoors. Plan the installation to use the fewest
number of elbows and turns. Use the fewest 90° turns
possible. Do not use vent runs longer than specified in
vent length chart. Determine the number of elbows you
will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10096988
06/2010
Download from Www.Somanuals.com. All Manuals Search And Download.
|