R
PORTABLE GASOLINE
GENERATORS
OWNER’S OPERATION AND INSTALLATION MANUAL
Generator Models: HWI3000, MGH3000G, MGH3000, MGH3000PR, MGH4000C, MGH4000CI,
MGH5000D, MGH5000DI, MGH5000DIE, MGH6000D, MGH6000DI, MGH6500IE, and MGH10000A
IMPORTANT: Read and understand this manual before operating or servicing
generator. Improper use of generator can cause serious injury. Keep this
manual for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
SAFETY
PRODUCT
IDENTIFICATION
INFORMATION
Continued
9. Only a qualified electrical service per-
son should service and repair generator.
• Generator produces high voltage.
Use extreme caution when working
on electrical parts.
Gas Cap/Fuel Gauge
Control
Panel
• Always remove spark plug wire from
spark plug before servicing. This will
prevent accidental starting.
•
When working on generator, avoid hot
muffler, exhaust manifold, and engine
parts. Severe burns may occur.
FUEL
F
120 Volt
Receptacle
• Do not work on generator when tired.
• Use only factory approved replace-
ment parts.
Full Power
Selector Switch
120 Volt
Receptacle
(GFCI)
1
2
0
V
O
L
T
S
10. Store generator in a well-vented area.
Make sure fuel tank is empty. Never
store with fuel in tank. Vapors may
reach an open flame or spark. Fire or
explosion may result.
R
E
S
E
T
T
E
S
T
F
U
L
L
P
O
W
E
R
120
ONLY
120
240V
120/240 VOLTS
E
120 Volt
Receptacle
(Duplex)
N
0
HO
M
0
0
0
0
0
0
RESET
RESET
UR
5
1/10
S
Provision for
Auto-Idle Switch
11. Never operate generator
• if engine speed changes greatly
• if engine misfires often
Run Lamp
Hour Meter
• if powered items overheat
• if electrical output drops
• if it is sparking
• if it produces smoke or flames
• if it vibrates at high levels
• if it has a damaged receptacle
Roll Cage
Gas Tank
120/240 Volt
Receptacle
Circuit
Breaker
12. Keep generator and nearby areas clean.
• Keep generator free of oil, mud, and
other foreign matter.
Choke
Lever
• Remove anything that creates slip-
pery areas around generator.
L
E
U
F
F
• Remove oily rags and other items
that create fire hazards.
Fuel
Valve
Lever
• Keep a fire extinguisher nearby.
Make sure it is rated ABC by the
NFPA. They are good for all uses.
Consult your local fire department.
• Keep fire extinguisher well main-
tained. Be familiar with its use.
13. Know how to stop engine quickly.
Know how to use all controls.
Ground
Lug
14. Prolonged exposure to loud noise can
cause hearing loss.
Starter Grip
• When working around generator,
wear approved hearing protection.
• Remember neighbors when using
generator.
Alternator
Engine
Engine ON/
OFF Switch
Oil Dipstick
Figure 1 - Portable Generator (Model MGH4000C Shown)
106813
3
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
HIGH AND LOW
GENERAL
VENTILATION
TEMPERATURE
OPERATION
INFORMATION
DANGER: Use only in well-
ventedareas.Makesureareahas
plenty of free-moving, fresh, out-
side air. Never run generator in
an enclosed or confined area.
Never run generator inside occu-
pied building. Engine exhaust
containspoisonouscarbonmon-
oxide gas. Overexposure will
causelossofconsciousnessand
will lead to death.
Master portable generators are rugged and
compact. These generators use brushless
alternators for dependable, trouble-free ser-
vice. Honda gasoline engines provide long
life under heavy use. Honda engines have
overheadvalves(OHV). Thisprovideshigh
performance with lower fuel consumption.
These engines are governed to maintain
enginespeedof3600RPMunderload.3600
RPM engine speed provides 120/240V, 60
Hz power.
Air temperature affects generator output.
Output drops 1% for each 10° temperature
rise above 60° F. Very low temperatures may
make the engine hard to start. See engine
owner’s manual for more information.
Thisgeneratorneedscoolingairtorunprop-
erly. Never block free-flowing, cooling air
to generator. Overheating will occur with-
out cooling air. This will damage the gen-
erator. Keep generator at least three feet
away from any object.
Additional Features
• Circuit breaker protection
• Spark-arresting muffler (except model
MGH10000A)
• Large fuel tank
• Oil alert system
DUST, DIRT, RAIN,
AND SNOW
• Electric starter (models MGH5000DIE,
MGH6500IE, and MGH10000A only)
• 15-Amp ground fault circuit interrupter
(GFCI) receptacle (Except HWI3000
Model)
WARNING: Do not use gen-
erator outdoors in rain or snow.
Do not use generator near stand-
ing water or snow. Do not use if
generator is wet or damp. Oper-
ating generator in these condi-
tions increases the risk of elec-
trocution. Severe injury or death
can occur.
UNPACKING
1. Remove generator from carton.
2. Remove any protective packaging ap-
plied to generator for shipment.
Do not use generator in extremely dusty or
dirtyconditions. Thiswillseverelyaffectits
life. Keep generator clean. Do not allow
dust, dirt, rain, or snow to collect on it.
Protect generator from outdoor elements.
3. Check for loose or missing parts. Check
for shipping damage. If any parts are
missing or damaged, promptly inform
dealer where you bought generator.
4. Battery cables are supplied for models
MGH5000DIE, MGH6500IE, and
MGH10000A only. These cables are in
a separate bag inside generator carton.
You must install these cables to engine.
See Battery, page 8 for installation in-
structions.
106813
4
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
MGH5000D
MGH5000DI
SPECIFICATIONS
MGH4000C
MODEL
HWI3000
MGH3000G
MGH3000
MGH3000PR MGH4000CI MGH5000DIE
Electrical
Rated Wattage
2500
2500
2500
2500
4000
5000
Rated Amperage
120 V
20.8
––
20.8
––
20.8
––
20.8
––
33.3
16.7
41.7
20.8
240 V
Receptacle
120-V Duplex
––
Yes
No
No
No
No
No
––
––
––
––
––
Yes
––
Yes
––
120-V, 20-A Duplex
120-V, 15-A GFCI
120-V Twist-Lock
120/240-V Twist-Lock
120-V Full-Power Switch
120/240-V, 50-A
Yes
No
No
No
No
Yes
No
No
No
No
Yes
No
No
No
No
Yes
Yes
30 Amp
20 Amp
Yes
30 Amp
20 Amp
Yes
No
No
General
Honda Engine H.P.
Honda Model
Fuel Type
5.5
GX160K1VX
Gasoline
3.9 qt.
5.5
GX160K1VX
Gasoline
3.9 qt.
5.5
GX160K1VX
Gasoline
3.9 qt.
5.0
GC160VXA
Gasoline
3.9 qt.
Yes
8
GX240K1VA
Gasoline
5 gal.
9
GX270VA
Gasoline
8 gal.
Fuel Tank Capacity
Oil Alert System
Start Method
Yes
Yes
Yes
Yes
Yes
Recoil
Recoil
Recoil
Recoil
84
Recoil
139
Recoil/Elec.
173
Weight (pounds)
85.5
85.5
85.5
* Single-phase, 1.0 power factor
MGH6000D
MODEL
MGH6000DI
MGH6500IE
MGH10000A
Electrical
Rated Wattage
6000
6500
10,000
Rated Amperage
120 V
Note: Ratings apply to SAE standard
conditions. Reduce ratings 3 /2% for
each 1000 feet above sea level and 1%
foreach10°Fahrenheitriseabove60°F.
50
25
57
28.3
83.3
41.7
1
240 V
Receptacle
120-V Duplex
Yes
––
Yes
––
Yes
––
120-V, 20-A Duplex
120-V, 15-A GFCI
120-V Twist-Lock
120/240-V Twist-Lock
120-V Full-Power Switch
120/240-V, 50-A
Yes
Yes
Yes
30 Amp
20 Amp
Yes
30 Amp
30 Amp
No
30 Amp
30 Amp
No
No
No
Yes
General
Honda Engine H.P.
Honda Model
Fuel Type
11
GX340K1VA
Gasoline
8 gal.
13
GX390K1VXE
Gasoline
8 gal.
20
GX620VXA3
Gasoline
13 gal.
Yes
Fuel Tank Capacity
Oil Alert System
Start Method
Yes
Yes
Recoil
Electric
247
Electric
350
Weight (pounds)
191
* Single-phase, 1.0 power factor
106813
5
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
FULL POWER SELECTOR
SWITCH
All models except HWI3000, MGH3000G,
MGH3000, MGH3000PR, MGH6500IE,
andMGH10000Ahaveafullpowerselector
switch on the control panel. The switch has
two positions: 120 VOLT ONLY, and 120/
240 VOLT.
ELECTRIC START
GENERATOR
FEATURES
(Models MGH5000DIE,
MGH6500IE, and MGH10000A)
Models MGH5000DIE, MGH6500IE, and
MGH10000A have electric starters. A bat-
tery is not supplied with generator. You
must provide a 12-volt, 32-amp-hour bat-
tery. For more battery information, see Bat-
tery, page 8.
OIL ALERT SYSTEM
Theoilalertsystemprotectstheenginefrom
low oil damage. This system automatically
shuts down the engine and prevents engine
restarting if the oil level falls too low.
120 VOLT ONLY: This position sends full
power to the 120V receptacles only. 240V
power is not available. Use this position
when powering 120V items only.
Note:Whenthishappens, theengineswitch
remains in the ON position. The oil alert
system is wired into the ON/OFF Switch.
GROUND FAULT CIRCUIT
INTERRUPTER RECEPTACLE
If this system shuts down the engine, the
engine will not start until you add oil. Add
oil to engine (see Engine Oil, page 7).
120/240VOLT:Thispositionsendsfullpower
to the 120/240V receptacle. It also powers the
120Vreceptaclesatreducedwattagecapacity.
All models (Except HWI3000) have a 120-
volt ground fault circuit interrupter (GFCI)
receptacle. The GFCI receptacle is on the
control panel or top cover of alternator (mod-
els MGH3000G, MGH3000, and
MGH3000PR only). The GFCI protects you
againsthazardouselectricalshockcausedwhen
your body becomes a path through which
electricity travels to reach ground. This could
happen when you touch an appliance or cord
that is ‘live’ through faulty mechanism, damp
or worn insulation, etc.
Note: Operate generator on a level surface.
If not level, the oil may flow away from the
oil level sensing device. This will cause the
oil alert system to shut down engine.
IMPORTANT: Do not move the full power
selector switch while powering electrical
items.Unplugallitemsbeforemovingswitch.
Failure to do so can damage switch. Models
HWI3000, MGH3000G, MGH3000,
See engine owner’s manual for more
information.
MGH3000PR,
MGH6500IE,
and
MGH10000A do not have this switch. These
models provide full power to all receptacles.
When protected by the GFCI, you may still
feel a shock, but the GFCI should cut it off
quickly. A person in normal health should
notreceiveseriousinjury. Note:Infantsand
very small children may still be affected.
Model
MGH3000PR
120/240 VOLT
Position
120 VOLT ONLY
Position
Test Procedure
Check the GFCI receptacle every month.
This insures it is working right.
Figure 3 - Full Power Selector Switch
1. Push black TEST button. Red RESET
button should pop out. This should trip
GFCI, resulting in no electrical power
at receptacle. Verify this by plugging
test lamp with good bulb into recep-
tacle. If lamp does not work, GFCI re-
ceptacle is good.
AUTO-IDLE SYSTEM
The Auto-Idle System allows the engine to
idle down or run at a slower speed when the
generator is not being used to supply power.
The Auto-idle system can be turned ON or
OFF by a rocker switch on the control panel.
When the switch is in the OFF position, the
engine runs at full speed all of the time. When
the switch is in the ON position, the engine
slows down to idle speed until an electrical
load is applied. When a load is applied to the
generator (an electrical item is plugged in and
turned on) the engine speeds up to the preset
speed required to produce the correct voltage.
Models HWI3000,
MGH3000G, MGH3000,
MGH4000C, MGH4000CI,
MGH5000D, MGH5000DI,
MGH6000D, and
MGH6000DI
ENGINE SW
ON
OFF
WARNING: If RESET button
does not pop out, do not use the
GFCI receptacle. Contact a quali-
fied electrician for repairs.
HONDA
Models
MGH5000DIE,
MGH6500IE, and
MGH10000A
ON
IMPORTANT: A minimum current load of
1 Amp is required to disengage the auto idle
solenoid and cause the engine to come up to
speed for correct voltage. Powering items at
reduced engine speed will damage genera-
tor and powered items.
OFF
START
ENGINE SW
CIRCUIT
BREAKER
Figure 2 - Engine Switch Location
106813
6
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
RECEPTACLE CIRCUIT
BREAKER
GENERATOR
FEATURES
The circuit breakers protect the receptacles
and alternator. Overloading generator will
trip circuit breaker. A short circuit in item
being powered will also trip breaker. If this
occurs, unplug electrical load from recep-
tacle. Let circuit breaker cool down. Push
circuit breaker button to reset.
Continued
Oil Level
At Top Of
Filler Neck
2. If the GFCI receptacle tests okay, re-
store power by pushing the RESET
button back in. The test lamp should
work at this time. IMPORTANT: You
must press the RESET button firmly
and fully. It should lock into place. If
the GFCI does not lock into place, do
not use receptacle. Contact a qualified
electrician for repairs.
Dipstick
Electricmotorsneedhigherstartingcurrent.
They require up to three-times their rated
wattage to start. The starting current needed
may be too high. This can cause nuisance
circuit breaker tripping. To help prevent
this, start electric motors first. Connect ad-
ditional items to generator after starting
motors. If this continues to happen, reduce
the total generator load.
Oil
Figure 7 - Checking Oil Level (Model
MGH4000C Shown)
FUEL
WARNING:Gasolinepresents
a hazard of fire or explosion.
Gasoline is flammable. Its vapor
is explosive.
• Keep fuel out of children’s
reach.
RESET
TEST
Normal
20
Tripped
20
•
Refuel generator in a well-
ventedarea.Donotfillfueltank
in the dark. Do not refuel while
engine is running. Unhook all
electrical loads and shut off
engine before refueling.
Figure 6 - Receptacle Circuit Breaker
Button
Note: High ambient temperature will cause
nuisance tripping.
Figure 4 - GFCI Receptacle
ENGINE CIRCUIT BREAKER
(Models MGH5000DIE,
MGH6500IE, and MGH10000A)
This circuit breaker, or fuse, protects the
battery charging circuit. A short circuit will
trip the circuit breaker. The circuit breaker
will also trip if you install battery wrong.
Push circuit breaker button to reset. On
Model MGH10000A, the fuse is located
inside of the Keyswitch box.
ENGINE OIL
We ship the generator without oil in the
engine crankcase. You must add oil before
starting engine. See engine owner’s manual
for specific oil type.
• Do not overfill fuel tank. Al-
ways allow room for fuel to
expand.Ifyouoverfilltank,fuel
can overflow onto hot engine.
This can cause fire or explo-
sion. After refueling, tightly
close fuel tank cap.
• Do not spill fuel. Fuel or fuel
vapor may ignite. If fuel spills,
make sure area is dry before
starting engine.
CHECKING OIL LEVEL AND
ADDING OIL
Follow steps below to check oil level. Make
sure engine is level and stopped.
ON
• Never smoke in refueling area.
Never allow open flames or
sparks in area.
• Store fuel in approved con-
tainer. Store fuel in a well-
ventedareafreeofopenflames
or sparks.
1. Remove dipstick (see Figure 7). Wipe
dipstick clean.
OFF
START
2. Insert dipstick into oil filler neck. Do
not screw it in. Oil level should be at
top of filler neck. Oil should cover most
of dipstick. For Model MGH10000A
only, the oil should be between the two
dots on dipstick.
ENGINE SW
Engine Circuit
Breaker Button
CIRCUIT
BREAKER
ON/push OFF
Use clean, fresh, unleaded gasoline. Use
gasoline with octane rating of 86 or higher.
Service station gasoline pumps should dis-
play the octane rating. Using gasoline with
lower octane level could damage engine.
Avoid getting dirt, dust, or water in fuel
tank. Do not mix oil with gasoline.
3. If level is low, fill to top of oil filler neck
(see Figure 7). For Model MGH10000A
only, fill to top dot on dipstick. Only use
oil recommended in engine owner’s
manual.
Figure 5 - Engine Circuit Breaker
Note: If oil level is too low, oil alert system
will shutdown engine and prevent engine
from restarting.
See engine owner’s manual for more
information.
106813
7
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
Always wear safety glasses when working
with battery. Make sure battery terminals
are clean. Make sure cable connections are
tight.
HANDLES AND
BATTERY
(Models MGH5000DIE,
TOP COVER
MGH6500IE, and MGH10000A)
(Model MGH10000A)
Always shut down engine before removing
or attaching battery cables. Always remove
the negative (–) cable first. Always attach
negative (–) cable last.
WARNING: Battery gives off
explosive gases. Keep sparks,
flames, and cigarettes away. Do
not remove or install battery
cables when engine is cranking
or running. Only service or use
battery in a well-vented area.
Follow the steps below to attach the handles
and top cover to Model MGH10000A:
1. Remove the two bolts, lock nuts, and
washers holding side panels to control
panel end of roll cage. Insert bolts with
washers through two holes in the
handle and then back through roll cage
and side screen panels (See Figure 8).
Tighten the lock nuts against the side
screen panels.
INSTALLING BATTERY
CABLES TO ENGINE
1. Attach the red, positive (+) battery
cable to the starter solenoid on engine
(see Figure 10). The starter solenoid is
located directly above the starter on
Model MGH10000A. This cable is fac-
tory installed.
WARNING: Battery contains
sulfuric acid. Contact with skin
or eyes may cause severe burns.
Do not tilt generator with battery
installed.Tiltingcouldcausebat-
tery acid to spill. Wear protective
clothing and face shield when
servicing. Keep out of children’s
reach.
2. Place top cover on top of generator roll
cage with notch on control panel side.
Use four #8 sems screws provided to
attach cover to roll cage (See Figure 9).
CAUTION:Donotovertighten
positive terminal on starter sole-
noid. Positive terminal could ro-
tate and cut into negative termi-
nal, causing a short.
Roll Cage
• If battery acid gets on your
skin, wash with water.
• Ifbatteryacidgetsinyoureyes,
flushwithwateratleast15min-
utes. Call a doctor at once.
Battery acid is poisonous.
• If swallowed, drink large
amounts of water or milk. Fol-
low with milk of magnesia or
vegetable oil. Call a doctor at
once.
2. Attach the black, negative (–) battery cable
to the engine block. Use the bolt, nut, and
two washers provided with the battery
cables. Use long mounting hole on oppo-
site side of engine from starter solenoid.
Attach cable as shown in Figure 11.
EL
FU
F
Washers
Bolts
Lock Nuts
Handle
CAUTION: If you remove bat-
tery, insulate the red, positive (+)
battery cable terminal. Insulate
with electrical tape. Exposed ter-
minal may spark when generator
runs.
Starter
Solenoid
Figure8–AttachingHandlestoRollCage
SEMS Screws
Top Cover
Red, Positive (+)
Battery Cable
IMPORTANT: Make sure battery connec-
tions are the correct polarity. Electric start
generators use negative ground, 12-volt DC
starting system.
Figure 10 - Connecting Red, Positive (+)
Battery Cable to Engine Starter Solenoid
(Model MGH6500IE Shown)
L
E
U
F
F
Models MGH5000DIE, MGH6500IE, and
MGH10000A have an electric starter. A
battery is not supplied with generator. You
must provide a 12-volt, 32-amp-hour bat-
tery.Thepositiveandnegativebatterycables
are supplied with generator. You must in-
stall these cables before mounting battery.
SEMS
Screws
Black,
Negative (–)
Battery Cable
Figure 9 – Attaching Top Cover to Roll
Cage
Figure 11 - Connecting Black, Negative (-)
Battery Cable to Engine Block (Model
MGH6500IE Shown)
106813
8
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
BATTERY
GENERATOR
Continued
GROUNDING
F
UL
L
P
O
TO ENGINE
W
E
R
120
O
NL
Y
BLOCK
120
240V
E
00
N
MOUNTING BATTERY TO
GENERATOR
1. Secure battery to generator by battery
hold-down system. This system con-
sists of the battery mounting bracket,
hook bolts, and nut (see Figure 12).
0
O
M
0
00
H
0
U
5
1/
RS
10
WARNING: You must prop-
erly earth-ground generator be-
TO STARTER
SOLENOID
fore starting. This will help guard
against deadly electric shock.
Only use grounded plugs with
generator.Onlyusegroundedex-
tension cords. Only use three-
wire or double-insulated power
Note: Model MGH10000A battery is
located on opposite side as shown (see
Figure 13).
Figure 14 - Connecting Positive and
Negative Cables to Battery
(Model MGH6500IE Shown)
tools.
2. Locate the red, positive (+) battery
cable from starter solenoid. Connect it
to the positive (+) battery terminal (see
Figures 14 and 15).
Grounding generator helps prevent electric
shock from a ground fault condition. Locate
ground lug on end of generator housing (see
Figure 16). Attach a #10 stranded-copper
ground wire to ground lug. Drive grounding
point into ground. Grounding point can be a
stake, grounding rod, or pipe. Grounding
point should be copper or brass. Attach
ground wire to grounding point. You must
supplythegroundwireandgroundingpoint.
These do not come with generator. Follow
the National Electrical Code and all state
and local codes. Consult your power com-
pany or a licensed electrician.
TO STARTER
SOLENOID
TO ENGINE
3. Locate the black, negative (–) battery
cable attached to engine block. Connect
it to the negative (–) battery terminal
(see Figures 14 and 15).
L
E
U
F
BLOCK
F
4. Check battery before starting engine.
Make sure fluid levels are full. Make
sure battery is charged.
See engine owner’s manual for more
information.
Figure 15 - Connecting Positive and
Negative Cables to Battery
(Model MGH10000A Shown)
Battery Mounting Bracket
WARNING: For a grounding
point, do not use metal pipe be-
ing used to carry combustible
materials or gases.
Nut
EXTENSION
CORDS
Only use grounded extension cords. Be sure
touseextensioncordwithproperwiregauge
size. See chart below.
F
U
LL
P
O
W
E
R
1
2
0
O
N
L
Y
1
2
0
2
4
0
V
E
N
0
O
M
0
0
0
0
0
H
U
0
5
R
S
1/
10
Battery
Ground Lug
L
FUE
F
Hook Bolt
Recommended Minimum Wire
Gauges (AWG) for Extension
Cords
Copper or
Brass
Grounding
Point
Figure 12 - Battery Hold-Down System
(Model MGH6500IE Shown)
Ampere
Load
AWG for Length of
Cord in Feet
Nut
Battery
Mounting
Bracket
50'
100'
150'
Battery
2
3
18
18
16
16
16
16
16
14
14
12
10
18
18
16
16
16
14
14
14
12
12
10
18
18
16
16
14
12
12
12
10
10
8
L
E
U
F
F
Ground Wire
Alternator
4
5
6
Figure 16 - Grounding Generator
(Model MGH4000C Shown)
8
Hook
Bolt
10
12
14
16
20
Figure 13 - Battery Hold-Down System
(Model MGH10000A Shown)
106813
9
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
ent size motors. For example: an elec-
1. Make two lists of items you want pow-
ered by generator. List all motors and
motor powered appliances in one. List
all lights, small appliances, etc. in the
other. For standby service to home or
building, only include items you must
power.
STANDBY
tric motor nameplate states 5 amps at
120 volts. 5 amps x 120 volts = 600
watts running. Multiply this figure by
3. This will show the starting watts
needed. 600 watts x 3 = 1800 watts to
start. When figuring the generator load
for motors, you must use the starting
watts figure. Do not use the running
watts figure. Note: Some motors re-
quire nearly the same wattage to run as
to start. These items include saws,
drills, hair dryers, and food mixers. See
Chart 1 for typical appliance wattage
examples.
INSTALLATION TO
HOME OR
BUILDING
WARNING: Have standby in-
stallation performed by a skilled,
licensed electrician. Do not let
anyone else wire into a utility
circuit. Personal injury, equip-
mentdamage,ordamagetohome
could occur.
2. Enter running watts of each item ex-
cept motors. The light bulb or appliance
nameplate lists its wattage. Remember,
1KW = 1000 watts. Note: The name-
plate may not list wattage. It may only
list volts and amps. The formula for
finding wattage is: Volts x Amps =
Watts. For example: An appliance
nameplate states 3 amps at 120 volts. 3
amps x 120 volts = 360 watts.
IMPORTANT: This generator will not
power your entire home. Most home utility
electric service is more than 60 amps. This
will exceed generator output. Only power
needed items during a power outage. Make
sure total wattage of electrical load does not
exceed rated wattage of generator.
4. Add watts and starting watts of all
items. This total must not be larger than
the rated wattage of your generator. It
is a good idea to have up to 25% extra
capacity for future needs or extra
equipment.
3. Electric motors present a special prob-
lem. They require up to three-times
their rated wattage to start. Chart 2,
below, shows starting watts for differ-
You may need to use this generator as a
standby power source. During a power out-
age, the generator will power selected items
in a building. Have generator and additional
wiring installed by a skilled, licensed elec-
trician. This is not a do-it-yourself job. Fol-
low all local codes.
Chart 1 - Typical Electric Appliance Wattages
Running Starting
Running Starting
Equipment
Watts
Watts
Equipment
Watts
Watts
Light bulb (100W)
Radio
Fan
100
150
200
400
100
150
600
400
1/2" Drill
Toaster
Coffee maker
Skillet
1000
1200
1200
1200
1200
1250
1200
1200
1200
1500
Television
WARNING: The electrician
mustinstalladouble-throwtrans-
fer switch. This isolates existing
electrical circuits from the utility
power line. If not isolated, gen-
erator output will back-feed into
utility power line. This may elec-
trocute a power company line
repair person.
Furnace fan (1/3 hp)
with blower
14" Chain saw
Water well pump
(1/2 hp)
Hot plate/range
(per burner)
10" Table saw
Water heater
(storage-type)
600
600
700
800
800
1000
1800
750
2100
2400
1000
1000
Vacuum cleaner
Sump pump (1/3 hp)
Refrigerator/freezer
6" Circular saw
Floodlight
1000
3000
1500
2000
1500
6000
5000
5000
Chart 2
Approximate Starting Watts*
Repulsion
DETERMINING
Motor
HP
Rating
Approximate
Running
Watts
Universal
Motors
Split
Phase
Motors
ELECTRICAL LOAD
FOR GENERATOR
Induction
Motors
Capacitor
Motors
(small appliance)
1/8
1/4
1/3
1/2
3/4
1
1 1/2
2
3
500
700
800
1100
1400
1700
2100
2450
3600
625
875
1100
1550
1750
2400
3100
3750
4620
5400
7900
1500
2100
2400
3300
4200
5100
6300
7350
10800
2250
3150
3600
4950
x
x
x
x
x
You must decide what electrical load your
generator can power. Do this before using
generator. Use the following four-step
method. It will help you select a load that is
not too large. Make sure total wattage of all
electrical loads does not exceed rated watt-
age of generator. For rated wattage of your
generator, see Specifications, page 5. Elec-
tric motors present a special problem when
figuring load. Read Step 3 carefully.
1000
1375
1750
2125
2625
3075
x
* – Always use starting watts, not running watts, when figuring correct electrical load.
x – Motors of higher horsepower are not generally used.
106813
10
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Model MGH10000A also has a 120/240V,
50-amp receptacle (see Figure 17).
POWER CORD AND PLUG
REQUIREMENTS
OPERATION
GENERAL INFORMATION
This generator is not large enough to power
your entire home. Do not connect generator
Model HWI3000 has only the 120V, 20-
amp duplex receptacle.
120V, 30-amp twist-lock receptacle
• NEMA L5-30P plug
Models MGH3000G, MGH3000 and
• Three-wire, 30-amp cord
toanyexistingelectricalcircuits.Plugitems MGH3000PR have only the 120V, 15-amp
directly into generator receptacles. Do not GFCI duplex receptacle.
exceedamperageratingofreceptacles.Only
120/240V, 20 or 30-amp twist-lock
receptacle
120V, 15-Amp GFCI Duplex
use grounded cords.
• NEMA L14-20P (20-amp) or L14-30P
(30-amp) plug
120V, 15-Amp Duplex
DANGER: Use only in well-
• Four-wire, 20-amp or 30-amp cord
ventedareas.Makesureareahas
plenty of free-moving, fresh, out-
side air. Never run generator in
an enclosed or confined area.
Never run generator inside occu-
pied building. Engine exhaust
containspoisonouscarbonmon-
oxide gas. Overexposure will
causelossofconsciousnessand
will lead to death.
120/240V, 20 or
30-Amp Twist-Lock
120/240V, 50-amp receptacle
• NEMA L14-50P
120 VOLTS
• Four-wire, 50-amp cord
RESET
TEST
120
ONLY
120
240V
EN
M
0
O
00
00
H
0
05
1
U
R
S
R
R
E
E
SE
SE
/1
T
T
0
120V, 30-Amp
Twist-Lock
DANGER:Neverconnectgen-
erator to any existing electrical
circuits.Thegeneratoroutputwill
back-feed into the utility power
line.Thismayelectrocuteapower
companylinerepairperson.Also,
if generator is powering electri-
calcircuits,thechanceofanelec-
trical fire exists.
RESET
RESET
240 VO
LTS
RESET
RESET
Note:Wesupplytheengineowner’smanual
with generator. Refer to that manual for
questions concerning engine operation.
USING RECEPTACLE
Note: Do not exceed amperage rating of
receptacles. Exceeding rating will trip re-
ceptacle circuit breaker.
120/240V, 50-Amp
(Model MGH10000A only)
Figure 18 - Cord and Plug Configurations
Figure 17 - Receptacle Locations
Use receptacles properly. Improper use could
damage generator. Use only grounded exten-
sion cords. Power only grounded or double-
insulated items. Do not overload receptacles.
All generators (except models HWI3000,
MGH3000G, MGH3000, and MGH3000PR)
have the following receptacles (see Figure 17):
• 120V, 15-amp GFCI duplex receptacle
• 120V, 30-amp twist-lock receptacle
• 120/240V, 20 or 30-amp twist-lock
receptacle
• 120V, 15-amp duplex receptacle
Continued
106813
11
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
4. Start the engine.
Choke Rod
Pulled Out
(Closed
OPERATION
A. Recoil Starter
Continued
Move engine lever or turn engine
Position)
PRESTART
switch to the ON position (see Figures
22 and 23). Remove slack from starter
rope by lightly pulling starter grip.
Next, pull starter rope briskly.
Operate generator on a firm, dry, and clean
surface. The surface must be level. Protect
generator from heavy dust, sand, dirt, rain,
orsnow. Donotlocategeneratornearstand-
ing water and snow. Make sure area is well-
vented.
IMPORTANT: Do not let starter grip
snap back against engine. Return it gen-
tly. This will prevent damage to starter.
Note: If engine does not start, check
the oil in the crankcase.Add oil as nec-
essary. Be sure engine is on a level sur-
face. See Oil Alert System, page 6.
WARNING: Only responsible
adults should use generator.
Neverletanyoneoperategenera-
tor without proper instructions.
Figure 20 - Choke Rod Closed (Model
MGH3000PR Only)
B. Electric Starter (Models
MGH5000DIE, MGH6500IE, and
MGH10000A Only)
Choke Button
Pulled Out
(Closed
Note: If oil level is too low, oil alert system
will keep engine from starting (see Oil Alert
System, page 6). Make sure oil level is full
before starting. See Engine Oil, page 7.
Turn the engine switch to the START
position (see Figure 24, page 13). Hold
it there until engine starts. When en-
gine starts, let switch return to the ON
position.
Position)
Before starting the engine, disconnect all
electric loads from generator.
IMPORTANT: Do not use electric
starter more than five seconds. Starter
motor damage may occur. If engine
fails to start, release the switch and wait
ten seconds.After ten seconds, try start-
ing again.
STARTING
Figure 21 - Choke Button Closed (Model
MGH10000A Only)
IMPORTANT: The engine speed is preset.
The throttle is locked in preset position. Do
not adjust throttle. Preset position lets en-
gine run at 3600 RPM under load. The
engine must maintain 3600 RPM for gen-
erator to create correct voltage. Running
engine at lower speeds will damage genera-
tor and powered items.
Note: If engine does not start, check
the oil in the crankcase.Add oil as nec-
essary. Be sure engine is on a level sur-
face. See Oil Alert System, page 6.
IMPORTANT: Never start generator with
electrical loads connected. Start engine be-
fore adding electrical loads.
5. As engine warms up, slowly move
choke lever fully to the right (see Fig-
ure 25, page 13). This opens the choke.
On Model MGH10000A, the choke
will automatically open.
1. Make sure gasoline tank is full. See
Fuel, page 7 for fuel information.
2. Move fuel valve lever to the ON posi-
tion except on Model MGH3000PR
(see Figure 19).
Figure 22 - Engine Lever In ON Position
(Model MGH3000PR Only)
Choke Lever (Closed Position)
3. Move choke lever fully to the left for
all models except MGH3000PR or
MGH10000A (see Figure 19). Pull
choke rod out for Model MGH3000PR
(see Figure 20) or choke button out for
Model MGH10000A (see Figure 21).
This closes the choke.
ENGINE SW
ON
OFF
Figure 23 - Engine Switch In ON Position
(All Models Except MGH5000DIE,
Note:You may not need to close choke
if engine is warm or air temperature is
high.
Fuel Valve Lever (ON Position)
MGH6500IE,
MGH3000PR)
MGH10000A,
and
Figure 19 - Fuel Valve Lever On, Choke
LeverClosed (ModelMGH4000CShown)
106813
12
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Note: The 250Volt/50Amp receptacle 8. Turn Auto-Idle switch ON. Make sure
OPERATION
is not connected through the Auto-Idle
circuit. The Auto-Idle switch must be
turned off to get full power out of this
receptacle (see Figure 26).
solenoid is engaged. When engaged, the
punger is pulled back into the solenoid.
Continued
9. If the engine speed is too slow, the en-
gine will want to "hunt" or speed up
and slow down repeatedly. When this
occurs, increase engine speed by adjust-
ing throttle stop screw on carburetor
(refer to Carburetor Adjustment in
Honda Engine Manual).
HONDA
6. TheAuto-Idle system should be turned
OFF when generator is shut down.
ON
OFF
START
Engine
Switch
ENGINE SW
Adjusting the Idle Speed
CIRCUIT
BREAKER
IMPORTANT: Adjust the idle speed only:
ON/push OFF
10. Replace the engine linkage cover
(Models MGH4000CI, MGH5000DI,
MGH5000DIE, MGH6000DI, and
MGH6500IE).
• If the idle speed becomes too high.
Figure 24 - Engine Switch (Models
• If the engine idle speed will not regulate (en-
gine idles and speeds up again and again).
MGH5000DIE,
MGH6500IE,
and
MGH10000A Only)
1. Turn Auto-Idle switch OFF. Start en-
gine. Allow engine to warm up with no
load for five minutes.
Choke Lever (Open Position)
Solenoid Mounting Bracket
M8 Nut
WARNING:Alwayssettheidle
speedbeforeturningontheAuto-
Idle. If idle speed is not set, the
largerresistoronthecontrolboard
may become hot. Heat from the
resistor may damage the protec-
tive coating on the control board.
E
N
G
IN
E
O
F
F
Figure 25 - Choke Lever Opened (Model
MGH6500IE Shown)
2. Remove engine linkage cover (Models
AUTO-IDLE OPERATION
MGH4000CI,
MGH5000DI,
IMPORTANT:Neverstartenginewithelec-
trical loads connected. Start engine before
adding electrical loads.
MGH5000DIE, MGH6000DI, and
MGH6500IE).
3. Push plunger into solenoid body to manu-
ally engage solenoid and set idle speed.
1. If engine is cold, turn the Auto-Idle
switch OFF (see Figure 26).
Figure 27 - Solenoid Bracket Location,
Models MGH4000CI, MGH5000DI,
MGH5000DIE, MGH6000DI, and
MGH6500IE Only
4. Loosen the M8 nut that holds the sole-
noid mounting bracket to the generator
(Models MGH4000CI, MGH5000DI,
MGH5000DIE, MGH6000DI, and
MGH6500IE. See Figure 27). Do not
loosen bolt that holds the solenoid
mounting bracket to the generator on
Model MGH10000A (see Figure 28).
2. Start engine. Allow engine to warm up
with no load for five minutes.
3. TurnAuto-Idle switch ON. Engine will
slow to idle speed. Engine idle speed
is preset. Idle speed adjustment should
not be necessary.
Solenoid
Mounting
Bracket
4. Operate generator according to speci-
fications outlined in owner's manual.
5. Slowly pull solenoid bracket away from
engine (on Model MGH10000A this will
require bending the bracket slightly).
5. Engine will automatically increase to
normal operating speed when you plug
load into any generator outlet.
6. With a volt meter, check the no-load
output voltage at the 120-volt duplex
receptacle. At proper idle speed (2680
minimum RPM) the meter should read
50-60 volts. Lower settings will cause
the Auto-Idle to not operate properly.
Bolt
Auto-Idle Switch
120 VO
LTS
RESET
TEST
A
u
to
-
Id
le
O
N
O
F
F
E
N
M
0
0
7. After reaching proper idle speed,
tighten M8 nut to secure solenoid
mounting bracket (Models MGH4000CI,
0
0
HOURS0
0
1/10
0
5
R
R
E
E
S
S
E
E
2
4
T
T
0
V
O
L
T
S
R
R
E
E
S
S
E
E
T
T
MGH5000DI,
MGH5000DIE,
MGH6000DI, and MGH6500IE (see
Figure 27).
Figure 28 - Solenoid Bracket Location,
Model MGH10000A Only
Figure 26 - Control Panel
106813
13
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
Fuel Valve Lever
(Off Position)
STOPPING ENGINE
OPERATION
Continued
IMPORTANT: The engine speed is preset.
The throttle is locked in preset position. Do
not adjust throttle.
HIGH ALTITUDE OPERATION
This generator will not perform well at high
altitudes without proper adjustment. See
engine owner’s manual for details.
Follow the steps below to stop engine.
1. Remove all electrical loads from gen-
erator (see Disconnecting Electrical
Loads). Remove electrical loads one at
a time.
ADDING ELECTRICAL
LOADS
2. Let engine run for two or three min-
utes after removing electrical loads.
This lets engine cool slightly.
IMPORTANT: Do not overload generator.
Makesuretotalwattageofallelectricalloads
does not exceed rated wattage of generator.
Overloading may shorten generator life. It
could also cause internal damage to genera-
tor. Overloading will trip circuit breaker.
3. Turn engine switch to the OFF posi-
tion (see Figure 29).
Figure 30 - Fuel Valve Lever Off (Model
MGH6500IE Shown)
4. Turn fuel valve lever off except on
Model MGH3000PR. Do this by mov-
ing valve lever fully to the left (see Fig-
ure 30).
IMPORTANT:(AllmodelsexceptHWI3000,
MGH3000,MGH3000PR,MGH6500IE,and
MGH10000A)Keepfullpowerselectorswitch
in the 120 VOLT ONLY position if only pow-
ering 120V items. Only move switch to 120/
240 VOLT position if powering 240V items.
MAINTENANCE
AND REPAIRS
WARNING: Only a qualified
electrical service person should
service and repair the alternator
on this generator. Use only fac-
toryapprovedreplacementparts.
1. Check items to be powered. Their
nameplate lists their wattage ratings.
Model
MGH3000PR
Note: The wattage ratings for some elec-
trical motors are misleading. They may
require up to three-times their rated watt-
age to start. You must figure total electri-
cal load wattage. Make sure total wattage
of all electrical loads does not exceed rated
wattage of generator. See Determining
Electrical Load For Generator, page 10.
CAUTION: The engine speed
is preset. The throttle is locked in
preset position. Do not adjust
throttle. Preset position lets en-
gine run at 3600 RPM under load.
The engine must maintain 3600
RPM for generator to create cor-
rect voltage. Running engine at
lower speeds will damage gen-
erator and powered items.
2. Start engine. Let engine reach full
speed.
Models HWI3000,
MGH3000G, MGH3000,
MGH4000C, MGH4000CI,
MGH5000D, MGH5000DI,
MGH6000D and
ENGINE SW
ON
3. Connect electrical loads one at a time.
If the load consists of electric motors,
start them first. Always start the larg-
est first. Start each motor individually.
OFF
MGH6000DI
CAUTION: Shut off generator
before performing maintenance.
DISCONNECTING ELECTRIC
LOADS
IMPORTANT: Keep generator level when
servicing.Neverturngeneratorupsidedown
or stand it on end to service.
HONDA
Remove electrical loads one at a time. Re-
move voltage sensitive items first. Voltage
sensitive items include TVs, VCRs, and
other home electronic items.
Note:Wesupplytheengineowner’smanual
with generator. Refer to that manual for
questions concerning engine maintenance
and repairs.
Models
MGH5000DIE,
MGH6500IE, and
MGH10000A
ON
OFF
START
ENGINE SW
CIRCUIT
BREAKER
Non-enginepartsrequirelittlemaintenance.
Keep generator clean. Use a damp cloth to
clean outside surfaces. Never use water to
clean generator. Water can cause damage to
internal parts. Use vacuum to clean air inlet
and outlet louvers of alternator.
ON/push OFF
Figure29-EngineSwitchInOFFPosition
106813
14
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
Use a fuel additive, such as STA-BIL® or an
equivalent,whenstoringgeneratorwithfuel
STORAGE
TECHNICAL
in fuel tank. This will minimize fuel gum SERVICE
WARNING: Remove all fuel
deposits from forming in engine.
fromfueltankbeforestoringgen-
erator.Storefuelinapprovedcon-
tainer. Store fuel in a well-vented
areafreeofopenflamesorsparks.
You may have further questions about as-
Cover and store generator in a clean, dry
place. Do not expose generator to extreme
high or low temperatures during storage.
sembling, operating, or maintaining this
product. If so, you can visit our Technical
contact our Technical Service Department
at1-800-858-8501(EnglishOnly).Youmay
also write to:
SERVICING THE
ENGINE
WARNING: The muffler be-
comesveryhotduringoperation.
The muffler remains hot for a
while after shutdown. Let engine
cool before storing.
DESA Specialty Products™
ATTN: Technical Service Specialty Products
P.O. Box 90004
Honda parts and services should be handled
by your nearest authorized engine service
firm. Check the yellow pages of your tele-
phone directory under the listing:
Bowling Green, KY 42102-9004
IMPORTANT: Keep generator level while
in storage. Never store generator upside
down or standing on end.
When contacting DESA Specialty Prod-
ucts™, have ready
Engines Gasoline, Honda
or visit:
Note:Wesupplytheengineowner’smanual
with generator. Refer to that manual for
questions concerning engine storage.
• Your Name
• Your Address
or call Honda direct:
1-800-426-7701
• Your Phone Number
• Model Number of Product
• Serial Number
• Date of Purchase (Include copy of receipt
for written requests).
TROUBLESHOOTING
Note: For additional help, visit DESA
International’stechnicalservicewebsite
WARNING: Only a qualified electrical service person should service
and repair generator. Use only factory approved replacement parts.
Note: See engine owner’s manual for engine troubleshooting.
OBSERVED PROBLEM
REMEDY
POSSIBLE CAUSE
No voltage when starting generator with no
electrical load
1. Replace capacitor
1. Defective capacitor
2. Winding short circuit or loose
connections
3. Defective rotor diode
4. Loss of residual magnetism
2. Check resistance of coils (see Electri-
cal Component Specifications, page 16)
3. Replace both diodes on rotor
4. Apply 12-volt battery to capacitor ter-
minals for 2-3 seconds
Voltage is less than normal voltage with no
electrical load
1. Set engine speed to 3720 RPM (62 Hz)
with no load
1. Engine speed too low
2. Replace both diodes on rotor
3. Check resistance of coils (see Electri-
cal Component Specifications, page 16)
4. Replace capacitor
2. Defective rotor diode
3. Partial short circuit in winding
4. Defective capacitor
Voltmeterreadingmorethan10%highwith
no electrical load
1. Set engine speed to 3720 RPM (62 Hz)
with no load
1. Engine speed too high
Voltmeter reading correct with no electrical
load, but more than 10% low when electri-
cal load is added
1. Replace both diodes on rotor
2. Do not overload generator
3. Contact an authorized engine service
center
1. Defective rotor diode
2. Electrical load too high
3. Engine not running properly
106813
15
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
ELECTRICAL
COMPONENT
SPECIFICATIONS
Resistance in Ohms
Stator
Main
Stator
Rotor
Rotor
Capacitor,
MFD
450 Volt
Auxiliary
Primary
Secondary
Diodes (2)
800 Volt
Model
Winding * Winding ∆ Winding † Winding †
HWI3000
MGH3000G
1.6
1.95
1.6
0.71
0.54
0.54
0.37
0.28
0.40
5.9
5.2
5.9
2.17
1.38
1.38
1.01
0.78
0.90
6.9
6.79
6.9
0.54
0.61
0.61
0.68
0.77
0.37
1.33
1.31
1.33
2.07
2.29
2.29
2.57
2.9
16
16
16
40
50
50
60
70
80
6 Amp
6 Amp
6 Amp
70 Amp
70 Amp
70 Amp
70 Amp
70 Amp
70 Amp
MGH3000, MGH3000PR
MGH4000C, MGH4000CI
MGH5000D, MGH5000DI
MGH5000DIE
MGH6000D, MGH6000DI
MGH6500IE
MGH10000A
0.50
*
∆
Connect T2 (green) and T3 (black). Measure resistance between T1 (red) and T4 (yellow).
Resistance between brown and white leads.
†
Remove diodes to check resistance.
WIRING DIAGRAMS
Stator
Receptacle
Black
120V/15A
(MGH3000)
L1
HOT
GFCI
Black
20A
WHITE
Receptacle
120V/20A
(HWI3000)
Circuit
T1
L1
T3
T2
T4
L2
Breaker
L2
L2
110/120V
Yellow
L1
Rotor
Stator
White
Auxiliary
Phase
C
D
Brown
Black
Main
Windings
T4
T3
Red
T2
T1
Yellow
Green
Figure31-WiringDiagram,ModelsHWI3000,MGH3000G,MGH3000,andMGH3000PR
106813
16
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
WIRING DIAGRAMS
Continued
Red
Black
Green/Yellow
Green
White
120V, 15A
Receptacle
White
120V, 15A
Receptacle
Red
120/240V 20A
Receptacle
120V, 30A
Receptacle
Circuit
Breaker
20A
White
Circuit
Breaker
25A
Duplex
T1
GFCI
T2
Circuit
Breaker
20A
Full Pwr
Selector
Switch
Red
Black
Black
Circuit
Breaker
25A
White
T3
LINE
T4
Yellow
Black
Hour
Meter
Green
Black
White
Green
Red
Red
Black
Green
Black
Red
Main
Windings
Auxiliary
Phase
Capacitor
White
Stator
White
T1 T4 T3 T2
T2
T1
T4
Rotor
Diode
Diode
Stator
White
T3
T1
L1
T2
T3
T4
L2
Green
220/240V
Red
Black
Yellow
110/120V
110/120V
Brown
Figure 32 - Wiring Diagram, Models MGH4000C, MGH5000D, and MGH6000D
White
Red
Black
White
Green/Yellow
Green
White
Red
120V, 15A
Receptacle
120/240V 20A
Receptacle
120V, 15A
Receptacle
120V, 30A
Receptacle
s1 s2
Circuit
Breaker
20A
White
•
Circuit
Breaker
T1
Duplex
GFCI
T2
20A, 25A
or 30A
To Solenoid
Circuit
Breaker
20A
Full Pwr
Selector
Switch
Red
Black
Black
Circuit
Breaker
20A, 25A
or 30A
White
T3
LINE
Black
White
T4
Yellow
Black
Hour
Meter
Green
Black
White
Green
Red
Red
Black
Green
•
Black
Red
Main
Windings
Auxiliary
Phase
Capacitor
White
Stator
White
T2
T1
T4
Rotor
Diode
Diode
Stator
White
T3
T1
L1
T2
T3
T4
L2
T1 T4 T3 T2
Green
220/240V
Red
Black
Yellow
110/120V
110/120V
Brown
Figure 34 - Wiring Diagram, Models MGH4000CI, MGH5000DI, MGH5000DIE, and MGH6000DI
Continued
106813
17
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
WIRING DIAGRAMS
Continued
Green/Yellow
Switch
Green
White
Black
120/240V 30A
Receptacle
120V, 15A
Receptacle
120V, 15A
Receptacle
120V, 15A
Receptacle
Circuit
Breaker
20A
s1 s2
•
White
Circuit
Duplex
GFCI
T1
Red
T3
White
Breaker
30A
To Solenoid
White
Black
T2
Circuit
Breaker
20A
Circuit
Breaker
30A
LINE
Hour
Meter
T4
White
Yellow
Green
Black
Black
Red
Black
Black
Red
Main
Windings
Auxiliary
Phase
Capacitor
White
Stator
T2 T3
220/240V
110/120V
White
T1 T4 T3 T2
Stator
White
T4
Rotor
T2
T1
T3
T1
L1
T4
L2
Green
Red
Diode
Diode
Black
Yellow
110/120V
Brown
Figure 35 - Wiring Diagram, Model MGH6500IE
White
Green
White
Green
Black
GFCI 125V, 15A
Receptacle
Black
125V, 30A
Receptacle
125V, 15A
Receptacle
250V 30A
Receptacle
Auto-Idle
Control Board
Red
250V 50A
Receptacle
Circuit
Breaker
20A
Circuit
Breaker
30A
White White
White
Red
Circuit
Breaker
45A
White
White
Black
To
Auto-Idle
Solenoid
Black
Black
Run
Circuit
Breaker
20A
Light
Circuit
Breaker
30A
Yellow
Circuit
Breaker
45A
Hour Meter
White
Black
Red
Green
Black
Black
Black
Yellow
Red
Black
White
Black
Black
Red
Main
Windings
Capacitor
White
Stator
T4
Rotor
Diode
T2
T1
T3
Stator
T1 T4 T3 T2
T1
L1
T2
T3
T4
L2
Diode
220/240V
110/120V
110/120V
Figure 36 - Wiring Diagram, Model MGH10000A
106813
18
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
1a
ILLUSTRATED
PARTS LIST
2a
For Models HWI3000,
MGH3000G, MGH3000, and
MGH3000PR Alternator
Assembly
1b
7
2b
This list contains replaceable parts used in
your generator. When ordering parts, fol-
low the instructions listed under Replace-
ment Parts on page 32 of this manual.
4
22
5
6
3
14
21
20
15
19
13
17
12
16
15
13
7
8
18
9
7
10
11
7
KEY PART
KEY PART
NO.
NUMBER
DESCRIPTION
QTY.
NO. NUMBER
DESCRIPTION
QTY.
099722-01
Alternator Assembly
(HWI3000)*
9
17587000
099891-01
099861-01
099842-01
26310000
27001005S Engine Flange
WLE-4
**
27001002
27001009S Diode
**
27001006
26327006
WLE-5
Ground Lug
1
1
1
1
4
1
4
1
1
2
1
1
4
4
1
10
11
12
13
14
15
16
17
18
19
20
21
22
Flanged Nut, 8mm
Bottom Cover
Draw Bolt
099722-02
Alternator Assembly
(MGH3000G, MGH3000,
and MGH3000PR)*
Top Cover (HWI3000)
Top Cover (MGH3000G,
MGH3000, and
MGH3000PR)
120V, 20A Duplex
Receptacle (HWI3000)†
120V, 15A Duplex (GFCI)
Receptacle (MGH3000G,
MGH3000 and
1
1
Screw, M6 x 16
1a
1b
099849-01
100074-01
Lock Washer, 1/4"
Stator
Bearing
1
1
2a
2b
104201-01
100445-01
Rotor
Fan
Bolt, 5/16-24 x 5/8"
Lock Washer, 5/16"
MGH3000PR)†
Circuit Breaker, 20 Amp †
1
1
3
4
5
6
7
8
22616009
27002002S Capacitor
26333000
099863-01
099701-01
099848-01
PARTS AVAILABLE - NOT SHOWN
1
1
1
13
1
Screw, M4 x 20
099866-03
Safety Information Decal
Safety Information Decal
Operation Decal
1
1
1
Terminal Block
Screw, M5 x 13
End Plate
099866-04
099867-02
† Includes fastening hardware.
* Includes reference numbers 1 through 22.
** Parts not available. Included in alternator assembly.
106813
19
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
ILLUSTRATED
PARTS LIST
23
For Models MGH4000C,
MGH4000CI, MGH5000D,
MGH5000DI, MGH5000DIE,
MGH6000D, MGH6000DI,
MGH6500IE Alternator
25
24
22
9
15
21
20
Assembly
19
9
10
This list contains replaceable parts used
in your generator. When ordering parts,
8
follow the instructions listed under Re-
placement Parts on page 32 of this
manual.
14
7
18
6
5
13
16
12
4
1
17
2
11
3
PART NUMBER FOR MODEL
MGH5000D
KEY MGH4000C
NO. MGH4000CI
MGH5000DI
MGH5000DIE MGH6000DI MGH6500IE
MGH6000D
DESCRIPTION
QTY.
099723-01
099723-02
099844-01
099701-01
099760-01
099863-01
099863-02
17587000**
M11084-26
099847-02
WLE-5
099723-03
099844-01
099701-01
099760-01
——
099723-04
099844-01
099701-01
099760-01
——
Alternator Assembly
End Cover
Screw, M5 x 13
Bushing
Terminal Block (4-block)
Terminal Block (2-block)
Ground Lug
Screw, #10-16 x 3/8"
Stator Bolt
Lock Washer, 5/16"
Bearing Housing
Capacitor
Terminal Post
Stator
1
1
6
1
1
1
1
1
4
4
1
1
4
1
1
4
1
1
1
1
2
1
1
1
4
4
1
2
3
4
5
6
7
8
099844-01
099701-01
099760-01
099863-01
099863-02
17587000**
M11084-26
099847-01
WLE-5
099863-02
17587000** 17587000**
099863-02
M11084-26
099847-03
WLE-5
099843-01
27006001S
100054-01
*
M11084-26
099847-04
WLE-5
099843-01
27007004S
100054-01
*
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
099843-01
27004002S
——
099843-01
27005003S
——
*
*
27003002
27003002
27003002
27003002
Fan Bracket
27003015S** 27003015S** 27003015S** 27003015S** Screw, M8 x 20
099891-01
099892-01
099842-01
27003003
27003012S
*
27003008
27003007S
26322004**
WLE-6**
099891-01
099892-01
099842-02
27003003
27003012S
*
27003008
27003007S
26322004**
WLE-6**
099891-01
099892-01
099842-03
27003003
27003012S
*
27003008
27003007S
26322004** 26322004**
099891-01
099892-01
099842-04
27003003
27003012S
*
Rotor Nut, Flanged 8mm
Foam Pad
Draw Bolt
Bearing
Diode
Rotor
Fan
Engine Flange
Bolt, 3/8-16 x 5/8"
Lock Washer, 3/8"
27003008
27003007S
WLE-6**
WLE-6**
* Part not available by itself. Must purchase Alternator Assembly.
**Available at your local hardware store.
106813
20
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
19
ILLUSTRATED
PARTS LIST
18
20
For Model MGH10000A
Alternator Assembly
13
17
8
This list contains replaceable parts used in
yourgenerator.Whenorderingparts,follow
the instructions listed under Replacement
Parts on page 32 of this manual.
21
15
26
10
12
24
14
5
11
23
25
1
2
6
4
16
22
9
7
3
KEY
NO.
PART
NUMBER
DESCRIPTION
QTY.
1
Stator
*
*
1
1
1
1
1
2
1
1
4
4
1
6
1
1
1
2
1
1
1
1
1
1
4
1
2
1
1
2
Rotor
3
Draw Bolt
Fan
103188-01
103191-01
103192-01
103193-01
103194-01
103195-01
099847-05
099891-01
103189-01
099701-01
103198-01
103199-01
103200-01
27003012S
103201-01
099845-02
103204-01
099892-02
103202-01
103190-01
**
4
5
Balancing Disc
Lifting Eyes
D.E. Bracket
N.D.E. Bracket
Mounting Bolts
Nuts
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
†
Top Box
Screw and Washer
Plastic Cap
Bearing
Borelly Washer
Diode
Terminal Block
Capacitor
Tie Wrap
Foam Pad
Capacitor Bracket
Engine Flange
Screw M8 x 20
'O' Ring
Washer
Hex Head Nut
Alternator Assembly
103203-01
WLE-5
099891-01
102938-01
* Part not available by itself. Must purchase Alternator Assembly.
** Standard hardware item available from local hardware store.
106813
21
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
ILLUSTRATED
PARTS LIST
1
For Model MGH3000G
Alternator Assembly
This list contains replaceable parts used in
yourgenerator.Whenorderingparts,follow
the instructions listed under Replacement
Parts on page 32 of this manual.
3
2
4
7
4
7
4
6
10
5
11
6
6
8
9
12
12
KEY
NO.
PART
NUMBER
DESCRIPTION
QTY.
1
099831-01
WLE-4
Handle (includes 2 spacers)
1/4" Lock Washer
M6 x 35 Screw
1
2
2
3
1
3
2
1
1
1
1
2
2
3
099769-01
NEC-5C
4
5/16-18 Nut
5
099754-01
13401000
WP-5C
Engine Spreader
Rubber Bumper
6
7
5/16" Flat Washer
5/16-18 x 1" Screw
5/16-18 x 11/2" Screw
Isolator Spacer
8
19165004
04110002
099767-01
21834000
19166004
9
10
11
12
5/16 x 11/2" Washer
5/16-18 x 2" Screw
Note: Fuel tank is available from Engine Mfg. Co. only.
106813
22
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
ILLUSTRATED
PARTS LIST
1
For Models HWI3000, MGH3000,
and MGH3000PR Roll Cage
This list contains replaceable parts used in
yourgenerator.Whenorderingparts,follow
the instructions listed under Replacement
Parts on page 32 of this manual.
3
4
3
4
2
3
4
7
3
3
4
5
6
6
8
5
5
9
4
3
4
7
3
4
3
3
KEY
NO.
PART
NUMBER
105155-01
099754-01
NEC-5C
DESCRIPTION
Roll Cage
QTY.
1
2
3
4
5
6
7
8
9
1
1
9
7
3
2
1
1
1
Engine Spreader
Lock Nut, 5/16-18
Flat Washer, 5/16"
Shock Mount
WP-5C
099853-02
04110002
14138000
21834000
100406-01
Screw, 5/16-18 x 11/2
Ground Strap
Washer, 5/16" x 11/2"
Bolt, 5/16-18 x 3/4"
106813
23
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
ILLUSTRATED
PARTS LIST
For Models MGH4000C,
MGH4000CI, MGH5000D,
MGH5000DI, MGH5000DIE,
MGH6000D, MGH6000DI,
and MGH6500IE
Fuel Tank and Roll Cage
3
FUEL
F
5
1
2
4
15
26
24
9
23
25
27
6
7
7
6
8
1
11
13
29
FUEL
2
F
24
10
22
14
11
16
21
10
20
23
23
10
16
11
24
11
16
14
13
29
12
16
10
18
16
19
16
11
13
17
28
16
11
17
24
16
11
24
28
9
106813
24
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
This list contains replaceable parts used in your generator. When ordering parts, follow the
instructions listed under Replacement Parts on page 32 of this manual.
ILLUSTRATED
PARTS LIST
For Models MGH4000C, MGH4000CI, MGH5000D, MGH5000DI,
MGH5000DIE, MGH6000D, MGH6000DI, MGH6500IE
Fuel Tank and Roll Cage
KEY MGH4000C MGH5000D
NO. MGH4000CI MGH5000DI MGH6000DI MGH6500IE
MGH5000DIE
MGH6000D
DESCRIPTION
QTY.
1
2
3
4
5
6
7
8
9
25954000
099832-01
25978000
HC4-8C
099701-01
19508001
25985005
099743-01
099752-02
25954001
107021-01
—
25954001
107021-01
—
25954001
107021-01
—
Gas Cap/Fuel Gage
Gas Tank (with 90° fitting)
Breather Assembly
Screw, 1/4-20 x 1"
Screw, M5 x 10
Gas Line Clamp
Fuel Line
Fuel Filter
1
1
1
4
1
2
1
1
1
5
3
8
10
1
3
3
1
9
11
2
1
2
1
2
4
3
2
4
1
1
1
2
2
—
—
—
099701-01
19508001
25985005
099743-01
106063-01
—
103880-01
—
NEC-5C
14138000
099853-02
WLE-5
099701-01
19508001
25985005
099743-01
106063-01
—
103880-01
—
NEC-5C
14138000
099853-02
WLE-5
099701-01
19508001
25985005
099743-01
106063-01
—
103880-01
—
NEC-5C
14138000
099853-02
WLE-5
Roll Cage
10 103880-01
—
11 NEC-5C
—
12 14138000
13 099853-02
14 WLE-5
15 WLI-3
16 WP-5C
—
17 HC5-14C
18 099756-01
19
20
21
22 100410-01
23 M10908-74
—
24 WP-4C
25 099965-01
26 WP-3C
27 103676-01
Lock Nut, 1/4-20
Lock Nut, 1/4-20
Lock Nut, 5/16-18
Lock Nut, 5/16-18
Ground Strap
Shock Mounts
Lock Washer, 5/16"
Lock Washer, #10
Flat Washer, 5/16"
Flat Washer, 5/16"
Bolt, 5/16-18 x 1 3/4"
Engine Spreader
Hook Bolt, 5/16-18
Battery Mounting Bracket
Lock Nut, 5/16-18
Sems Screw, #8-18 x 1/2"
Screw, 1/4-20 x 1/2"
Screw, 1/4-20 x 1/2"
Washer, 1/4"
WLI-3
—
WP-5C
WLI-3
WLI-3
—
WP-5C
—
WP-5C
HC5-14C
099756-01
—
HC5-14C
099756-01
099750-01*
099749-01*
NEC-5C*
100410-01
M10908-74
M10908-74*
WP-4C
099965-01
WP-3C
103676-01
HC4-16C
107110-01
HC5-14C
099756-01
099750-01
099749-01
NEC-5C
100410-01
—
M10908-74
WP-4C
099965-01
WP-3C
—
—
—
—
—
100410-01
M10908-74
—
WP-4C
099965-01
WP-3C
103676-01
HC4-16C
107110-01
Linkage Cover
Washer, #10
90° Fitting with barbs
Bolt, 1/4-20 X 2"
Spacer .25 X .500
103676-01
HC4-16C
107110-01
28
29
—
—
PARTS AVAILABLE - NOT SHOWN
099866-02
100003-01
—
—
—
—
Safety Information Decal
Operation Decal
Operation Decal
Battery Cable (Positive, Red)
Battery Cable (Negative, Black)
Fuel Line Grommet
1
1
1
1
1
3
100003-01
100003-02*
099873-01*
099873-02*
03175000
100003-01
—
—
—
—
—
—
100003-02
099873-01
099873-02
03175000
03175000
03175000
*
Only on MGH5000DIE electric start models
106813
25
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
ILLUSTRATED
PARTS LIST
36
For Model MGH10000A Fuel
Tank and Roll Cage
35
33
9
37
10
9
23
37
10
25
10
36
10
9
24
22
28
29
30
31
2
32
26
37
10
25
27
18
37
34
19
12
20
10
10
9
9
18
10
21
19
16
17
20
15
14
10
21
FUEL
F
1
13
10
9
4
6
5
3
6
7
8
12
11
106813
26
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
ILLUSTRATED
PARTS LIST
For Model MGH10000A
Fuel Tank and Roll Cage
KEY
NO.
PART
NUMBER
DESCRIPTION
QTY.
1
2
3
4
5
6
7
8
079503-25AA
105905-01
105906-01
102933-03
102932-01
WP-16C
C4-12C
100135-01
NEC-5C
Gas Tank Assembly
Roll Cage
Axle Mount
Axle
Wheels
Flat Washer, 1"
Cotter Pin
U-Bolt
Lock Nut, 5/16-18
Flat Washer, 5/16"
Lock Nut,1/4-20
Flat Washer, 1/4"
Gas Cap w/Fuel Gage
Fuel Line
1
1
1
1
2
4
2
2
22
30
4
8
1
1
1
1
1
2
2
2
4
2
1
1
3
1
4
2
2
1
1
1
1
1
1
8
6
This list contains replaceable parts used in
your generator. When ordering parts, fol-
low the instructions listed under Replace-
ment Parts on page 32 of this manual.
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
WP-5C
103880-01
WP-4C
097190-06
M51151-02
M10990-3
106988-01
25985008
105035-01
103046-01
103057-01
H8C5-20C
099750-01
099749-01
105908-01
17529000
102962-02
H5C4-24C
26302006
WLI-8
14138000
M10908-74
WLE-5
106775-02
106775-01
106776-01
100410-01
HC5-14C
Bushing
Barbed Connector, 1/4"
Fuel Line
Handle
Grip
Plug
Bolt, 5/16-18 x 2.5"
Bolt, J-Hook 5/16-18
Battery Bracket
Battery Mount
Shock Mount
Spreader
Bolt, 1/4-20 x 3"
Bolt, 1/2-10 x 1"
Internal Tooth Lockwasher
Ground Strap
Tapping Screw, 1/4-20 x .5"
External Tooth Lockwasher
Side Panel
Side Panel
Top Cover
Sems Screw, 8-18
Bolt, 5/16-18 x 1.75"
PARTS AVAILABLE - NOT SHOWN
099866-05
Safety Information Decal
Operation Decal
Battery Cable (Positive, Red)
Battery Cable (Negative, Black)
Screw, 1/4-20 x .75"
Muffler
1
1
1
1
2
1
1
100003-04
099873-01
099873-05
HC4-6C
105951-01
106108-01
Muffler Hanger
106813
27
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
ILLUSTRATED
2
PARTS LIST
12
2
For Models MGH4000C,
MGH4000CI, MGH5000D,
MGH5000DI, MGH5000DIE,
MGH6000D, MGH6000DI, and
MGH6500IE Control Panel
5
1
3
RES
T
E
6
T
EST
Reset
Reset
120 Vol
This list contains replaceable parts used in
your generator. When ordering parts, fol-
low the instructions listed under Replace-
ment Parts on page 32 of this manual.
8
t
4
7
F
U
L
L
L
1
P
O
2
13
0
ONL
Y
W
13
E
R
S
E
1
2
E
0
/2
C
T
4
0
O
V
R
1
2
0
/2
4
0
V
O
L
T
7
S
R
R
E
E
S
ET
ET
S
14
ENM
00000005
HO
UR
S
1/10
11
9
10
PART NUMBER FOR MODEL
MGH5000D
KEY
NO.
MGH4000C MGH5000DI MGH6000D
MGH4000CI MGH5000DIE MGH6000DI MGH6500IE DESCRIPTION
QTY.
1
2
3
4
5
6
7
103349-01
22616009
099833-01
104202-01
100445-01
099956-01
22616009
—
103349-02
22616009
099833-01
104202-01
100445-01
099956-01
—
22616011
—
099834-01
—
101350-01
099760-01
100410-01
100149-01
22261000
099997-01
103348-02
103348-06
100177-07
103349-03
22616009
099833-01
104202-01
100445-01
099956-01
—
103349-05
22616009
099833-01
104202-01
100445-01
—
Control Panel
Circuit Breaker, 20 Amp *
1
2
1
1
1
1
2
2
2
1
1
1
1
4
1
8
1
1
1
1
120V, 30A Twist-Lock Receptacle *
120V, 20A Duplex Receptacle *
120V, 15A Duplex (GFCI) Receptacle *
Full Power Selector Switch *
Circuit Breaker, 20 Amp *
Circuit Breaker, 25 Amp *
Circuit Breaker, 30 Amp *
120/240V, 20A Twist-Lock Receptacle *
120/240V, 30A Twist-Lock Receptacle *
Hour Meter
Bushing
Sems Screw, #8-18 x 1/2"
Control Box
U-Nut
Switch Plug
—
—
—
—
22616010
099834-01
—
22616010
—
8
099834-01
—
099835-01
101350-01
099760-01
100410-01
100149-01
22261000
099997-01
—
9
101350-01
099760-01
100410-01
100149-01
22261000
099997-01
103348-01
103348-05
100177-07
101350-01
099760-01
100410-01
100149-01
22261000
099997-01
103348-03
103348-07
100177-07
10
11
12
13
14
†
Control Panel Assembly
Control Panel Assembly - Auto Idle Models
Panel Schematic Decal
†
∆
103348-09
100177-07
* Includes fastening hardware
∆ Not shown
† Includes reference numbers 1 through 13
106813
28
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
ILLUSTRATED
PARTS LIST
For Model MGH10000A Control
Panel
2
2
14
This list contains replaceable parts used in
your generator. When ordering parts, fol-
low the instructions listed under Replace-
ment Parts on page 32 of this manual.
6
16
1
RESET
TEST
3
11
Reset
Reset
120 Vol
t
12
7
Au
5
t
o
Idle
O
ff
4
5
O
n
Sel
e
c
t
o
r
12
200
V
p;
15
t
Reset
Reset
5
8
9
Reset
Reset
E
NM
0000000
H
OURS
5
1
/
1
0
13
10
4
KEY
NO.
PART
NUMBER
DESCRIPTION
QTY.
1
2
3
4
5
6
7
8
103182-01
22616009
099833-01
100410-01
22261000
100445-01
103183-01
103184-01
26299000
101350-01
099834-01
22616010
099760-01
103185-01
100366-01
104202-01
102927-01
100177-05
103257-01
103258-02
Control Panel
Circuit Breaker, 20 Amp
1
2
1
16
20
1
1
2
1
1
1
2
1
1
1
1
1
1
120V, 30A Twist-Lock Receptacle
Sems Screw, #8-18 x 1/2"
U-Nut
20V, 15A Duplex (GFCI) Receptacle
125/250V, 50A Receptacle
Circuit Breaker, 45 Amp
Run Light
9
10
11
12
13
14
15
16
†
Hour Meter
120/240V, 20A Twist-Lock Receptacle
Circuit Breaker, 30 Amp
Bushing
Control Box
Rocker Switch
120V, 20A Duplex Receptacle
Control Panel Assembly
Panel Schematic Diagram
Auto Idle PC Board Kit
Solenoid Assembly Kit (With Bracket)
∆
∆
∆
1
1
† Includes reference numbers 1 through 16
∆ Not shown
106813
29
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
ILLUSTRATED
PARTS LIST
For Solenoid and Control Board
Assemblies and Mounting
12
10
6
13
14
7
8
10
11
9
8
Solenoid Assembly and Mounting
3
D
E
S
A
IN
T
E
R
N
S2
A
T
IO
5
N
S1
A
L
L1
4
L2
2
1
Control Board Assembly and Mounting
106813
30
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
ILLUSTRATED
PARTS LIST
For Solenoid and Control Board
Assemblies and Mounting
This list contains replaceable parts used in
your generator. When ordering parts, fol-
low the instructions listed under Replace-
ment Parts on page 32 of this manual.
KEY
NO.
PART
NUMBER
DESCRIPTION
QTY.
1
2
3
4
5
6
100105-01
26499000
100321-01
WP-C3
26514000
100324-03
Control Board Assembly
Hex Head Screw, 10-32 x 3/4"
Nylon Spacer
Flat Washer, #10
Lock Nut, 10-32
Solenoid Assembly (Includes
Plunger, Nut, and Lock Washer)
Retaining Ring*
Linkage Rod*
Linkage Rod
1
4
4
4
4
1
1
1
1
1
1
1
1
1
1
1
7
8
103812-01
100755-02
100755-01
22822000
102939-01
100756-01
103811-01
100328-01
02407002
100329-01
9
10
Roll Pin
Solenoid Mounting Bracket*
Solenoid Mounting Bracket
Nylon Washer*
11
12
13
14
Bolt, M8 x 25mm †
Flat Washer, 5/16" †
Lock Nut, M8 †
PARTS AVAILABLE NOT SHOWN
100320-01
100322-01
100322-02
100366-01
100334-01
Yellow Wire
1
1
1
1
1
White Wire (with 2 Flags)
White Wire (with 1 Flag and 1 Spade)
Rocker Switch
Auto-Idle Decal
* Model MGH10000A Only
† All Models Except MGH10000A
106813
31
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
FBD
REPLACEMENT
PARTS AND
REPAIR SERVICE
1349 Adams Street
Bowling Green, KY 42103-3414
270-846-1199
Note: Only use original replacement parts.
Thiswillprotectyourwarrantycoveragefor
parts replaced under warranty.
1-800-654-8534
ACCESSORIES
Master Part Distributors
1251 Mound Avenue NW
Grand Rapids, MI 49504-2672
616-791-0505
EachAuthorizedServiceCenterisindepen-
dently owned and operated.
For additional Service Center or warranty
information, call 1-800-858-8501 or visit
our Technical Service web site at
For original replacement parts and accesso-
ries,contactyournearestAuthorizedDealer
or Authorized Service Center for this prod-
uct. If they can not supply the part or acces-
sory,contactyournearestPartsCentrallisted
below.EachAuthorizedDealer,Authorized
Service Center, and Parts Central is inde-
pendently owned and operated.
1-800-446-1446
Bowden Electric Motor Service
1681 S. Wesleyan Blvd.
Rocky Mount, NC 27803
252-446-4203
WARRANTY SERVICE
If product requires warranty service, return it
to nearest Authorized Service Center. You
must show proof of purchase. If faulty materi-
als or workmanship caused damage, we will
repairorreplaceproductwithoutcharge.Note:
Normal wear, misuse, abuse, neglect, or acci-
dental damage is not covered under warranty.
East Coast Energy
See pages 19 through 31 for an Illustrated
Parts List.
If you need additional referral information,
contact our Technical Service Department
(see Technical Service, page 15).
10 East Route 36
West Long Branch, NJ 07764-1501
1-800-755-8809
Laportes
2444 N 5th Street
Hartsville, SC 29550-7704
843-332-0191
In Canada call 1-800-561-3372 for parts
information.
MTA Distributors
555 Hickory Hills Blvd.
Nashville, TN 37189-9244
615-299-8777
NON-WARRANTY SERVICE
If product requires service, return it to near-
est Authorized Service Center. Repairs will
be billed to you at regular repair list prices.
Heavy-Duty Wheel Kit – PA2020
For Models MGH4000C,
MGH4000CI, MGH5000D,
MGH5000DI, MGH5000DIE,
MGH6000D, MGH6000DI,
MGH6500IE
Wheelbarrow-style wheel kit. Makes gen-
erator easy for one person to move.
This kit includes:
• Large 12-inch wheels for easy rolling
• Powder coated tubing and plated hard-
ware for long life
• Long handles with thick grips for greater
comfort and control
1-800-264-0225
Industrial Hardware
4109 Bainbridge Blvd.
Chesapeake, VA 23324-1403
804-543-2232
PARTS CENTRALS
1-800-788-0008
These Parts Centrals are privately owned
businesses. Theyhaveagreedtosupportour
customer’s needs by providing original re-
placement parts and accessories.
Mills Lawn and Garden
928 Commonwealth Place
Virginia Beach, VA 23464
757-361-9293
Tool & Equipment
5 Manila Drive
Tuco Industrial Products
5223 180th Street SW
Suite 4A-1
Lynnwood, WA 98037-4506
425-743-9533
1-800-735-1268
Hamden, CT 06514-0322
203-248-7553
1-800-397-7553
Grainger Parts Operations
1657 Shermer Road
Northbrook, IL 60062-5362
708-498-5900
1-800-323-0620
Completeinstallationinstructionsincluded.
Automatic Idle Kit – PA2010
For Models MGH4000C,
MGH5000D, MGH6000D, and
MGH6500IE
Automatically reduces engine speed when
no power is being used. Reduces fuel con-
sumption and engine noise. Increases en-
gine life.
Portable Heater Parts
342 North County Road 400 East
Valparaiso, IN 46383-9704
219-462-7441
1-800-362-6951
Completeinstallationandoperationinstruc-
tions included.
106813
32
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
NOTES
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
106813
33
Download from Www.Somanuals.com. All Manuals Search And Download.
R
PORTABLE GASOLINE GENERATORS
NOTES
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
106813
34
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S MANUAL
NOTES
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
_______________________________________________________________________________________________
106813
35
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model
Serial No.
Date Purchased
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard
written warranty. We make no other warranty, expressed or implied.
FIVE-YEAR LIMITED WARRANTY
GASOLINE PORTABLE GENERATORS
DESA Specialty Products™ makes no warranty with respect to the engine and engine components not of its manufac-
ture. They are subject to warranties of their manufacturers. Honda warrants the engine. See engine owner’s manual
for engine warranty information.
DESA Specialty Products™ warrants each generator, excluding engine, of its manufacture, to be free from defects in
material and workmanship for five years from the date of first purchase from an authorized dealer, provided that the
product has been properly installed, maintained, and operated in accordance with all applicable instructions. The bill
of sale or proof of purchase must be presented at the time a claim is made under this warranty.
This warranty is extended only to the original retail purchaser. This warranty covers only the parts and labor required
to restore this unit to its proper operating condition. Warranty parts must be obtained through factory authorized
dealers and service centers for this product. These dealers and service centers will provide original factory replace-
ment parts. Failure to use original factory replacement parts voids this warranty.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that
fail or become damaged as a result of misuse, abuse, negligence, accident, lack of proper maintenance, alteration,
modification, tampering, contaminated fuels, repair using improper parts, or repair by anyone other than an authorized
dealer or service center. Routine maintenance is the responsibility of the owner. Travel, handling, transportation, and
incidental costs associated with warranty repairs are not reimbursable under this warranty and are the responsibility of
the owner.
To the full extent allowed by the law of the jurisdiction that governs the sale of the product, this express warranty
excludes any and all other expressed warranties and limits the duration of any and all implied warranties, including
warranties of merchantability and fitness for a particular purpose to five years from the date of first purchase, and DESA
Specialty Products’™ liability is hereby limited to the purchase price of the product and DESA Specialty Products™
shall not be liable for any other damages whatsoever including indirect, incidental, or consequential damages.
Some states do not allow limitation of how long an implied warranty lasts or an exclusion or limitation of incidental
or consequential damages, so the above limitation of damages may not apply to you.
This warranty provides the original purchaser with specific rights. For information regarding those rights, please
consult the applicable state laws.
Bowling Green, KY 42102-9004
106813-01
REV. F
08/04