Master Lock Electric Heater WA 41 A User Manual

USER’S MANUAL  
INSTRUKCJA OBSŁUGI  
РУКОВОДСТВО ПО ПРИЕМЕНЕНИЮ  
WA 41 A  
WA 59 A  
UNIVERSAL OIL HEATERS  
NAGRZEWNICE NA OLEJ UNIWERSALNY  
НАГРЕВАТЕЛИ НА УНИВЕРСАЛЬНОЕ  
МАСЛО  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENGLISH  
To obtain full benefit from the WA 41 A and  
trouble free operation, read the following in-  
structions and information carefully.  
* The  
1x  
following  
items  
are  
packed  
within  
the  
combustion chamber:  
T-piece with built-in draught stabiliser  
for flue pipe connection  
cleaning shovel  
scraping tool to remove residue from  
combustion dish  
combustion dish  
burner ring  
spare card to seal the bottom of com-  
bustion chamber  
handle with bolts  
DESCRIPTION AND FUNCTION  
1x  
1x  
*
The control panel incorporates a  
switch, a locking device for the fuel and a  
pilot light.  
1x  
2x  
1x  
*
*
The electric pump motor drives the fuel  
pump, which is positioned in the tank.  
The fuel pump delivers fuel to the com-  
bustion dish and is controlled by means of  
the button above the control panel,  
2x  
1x  
pedal  
At position low, the consumption is approx.  
2,5 l/h. At position high, the consumption  
is approx. 4,3 l/h.  
One and another depends on viscosity.  
The main fan is controlled by a thermostat.  
As soon as the combustion chamber has warmed  
up sufficiently, the fan starts to operate.  
The burner is equipped with an air intake  
fan to supply air for combustion. This air  
combustion fan stops when the flame has  
FLUE PIPE  
For clean and trouble free combustion, it is  
essential that the flue pipe is installed correctly.  
a.  
b.  
*
*
minimum diameter of flue pipe: 150mm  
check that flue connections are well sea-  
led  
c.  
d.  
minimum flue height: 5 m  
the wind must be able to reach the top of  
the flue from all directions (e.g.: it may  
be necessary to extend flue above roof  
apex)  
all pipes should be vertical if possible,  
keep horizontal pipes to the absolute  
minimum  
avoid bends in the flue installation if  
possible but if unavoidable e.g. if flue  
has two bends because of installation  
through a wall or window, then:  
extinguished.  
Pipes φ 200 mm can be  
connected to this fan so that the combustion  
air can be sucked from outside the area to  
be heated.  
e.  
f.  
*
*
Most types of waste oil can be used, such as  
gearbox oil, gas oil, diesel oil, hydraulic  
oil, HBO 1, 2 and 3, but not those with a  
high viscosity, such as SAE90.  
DO NOT USE TRANSFORMER OIL WHICH MIGHT  
TO  
1.  
the pipe should be as high as  
possible within the building  
CONTAIN  
PERFORMANCE OF THE BURNER (PCB)  
SUBSTANCES  
DETRIMENTAL  
THE  
2.  
flue pipe outside the building  
When the pump motor stops, the flame will  
extinguish once the fuel in the burner dish  
is exhausted.  
should  
walled)  
be  
insulated  
(double  
3.  
the minimum height of the flue  
has to be increased to 7.5 m to  
compensate.  
WARNINGS  
1
There could be a possible danger of  
explosion if the burner is reignited while  
it is still warm.  
2
3
There must be sufficient air for combustion;  
make sure that the combustion air intake fan  
is never blocked.  
Modifications made to the burner by dealer  
or end user, invalidate the manufacturer's  
warranty.  
use a raincap  
INSTALLATION  
*
*
*
For  
prescriptions.  
The burner must be installed on a completely  
level, concrete floor.  
Check that the chose position presents no  
problem for:  
installation,  
consult  
the  
local  
- electrical supply 230V/2Amp.;  
- flue pipe installation;  
- combustion air supply.  
*
Open the top cover of the burner and remove  
the cover of the combsution  
chamber.  
-NLC-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMBUSTION CHAMBER (see figure 1)  
*
Place burner ring (1) in the burner pot and  
replace combustion chamber cover.  
Unlock the sliding bottom drawer (2) by  
means of pedal (3) and safety catch (6) and  
open.  
*
*
The bottom of the combustion chamber and  
combustion dish are now accessible, see  
figure 2.  
Ignition and cleaning can now be dealt with  
easily.  
IGNITION PROCEDURE  
1.  
Fill the tank with fuel. Slide the locking  
button on the control panel vertically to  
open the tank, which hinges forward.  
2.  
Switch to "0"; connect plug to electricity  
sypply and switch on at socket.  
3.  
4.  
Put capacity regulator in low position.  
Pour apporx. 1/3 litre of paraffin in the  
combustion dish. Crumple some paper into a  
ball, light it and drop into the dish to  
ignite the oil. Close and lock the sliding  
drawer. Check through the top cover that the  
sealing around the bottom of the combustion  
chamber is visible.  
5.  
Switch to "1". After about 5 minutes the  
combustion  
chamber  
will  
be  
warmed  
up  
sufficiently for the main fan and pump motor  
to come into operation. The orange pilot  
light will illuminate.  
6.  
7.  
After approx. 30 minutes, make any necessary  
adjustments to the draught stabiliser.  
During initial commissioning burn, there  
will be some fumes from the heat resistant  
paint finish and because the combustion  
chamber has been oiled against corrosion.  
These fumes will cease after about 30 to 40  
minutes.  
SAFEGUARDS  
*
The burner is equipped with a thermostat  
controlling the flame. Should the flame be  
extinguished for any reason, this thermostat  
will stop the fuel pump as well as the main  
fan. For causes, see chapter "Location of  
faults".  
An overheating thermostat which shuts off  
the fuel supply completely is reset by means  
of a push button in the  
burner. For causes, see chapter  
"Location of faults".  
The fuel supply system is equipped with an  
"overflow tube", through which the oil flows  
back into the tank incase the pipe to the  
burner becomes obstructed. After the flame  
*
*
has  
thermostat will switch off the burner. For  
causes, see chapter "Location of faults".  
The burner is equipped with an  
extinguished,  
the  
flame  
control  
*
"overflow security", located underneath  
the bottom of the combustion chamber. This  
will come into operation if, over a  
period, the fuel is not burnt completely.  
The excess fuel will flow from the  
combustion dish, via an inlet tube, into a  
small  
positioned  
container.  
on  
This container  
spring-loaded  
is  
micro  
a
switch. As soon as this container is half  
full, the fuel pump is switched off auto-  
matically. For causes, see chapter "Loca-  
tion of faults".  
The air combustion fan is equipped with a  
thermostat.  
*
Figure 1  
MAINTENANCE  
-GBB-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The heater requires very little maintenance and the  
regularity of such maintenance will depend greatly on  
the type(s) of waste oil being burnt. The cleaner the  
fuel, the less maintenance is required.  
In general:  
*
*
clean combustion dish and overflow tube daily;  
clean burner pot, burner ring and combustion  
chamber at least once a week. Ensure that the  
air intake holes of combustion chamber and  
lower side (3) at bottem connection are not  
obstructed;  
*
*
clean heat exchanger, fuel supply pipe, tank  
and filter once per heating season;  
combustion chamber bottom: as soon as the seal  
around the bottom of the combustion chamber is  
no longer visible, it is essential that it is  
replaced, normally this is once per heating  
season.  
*
*
Clean filling sieve, fuel tank and filter  
regularly.  
The water in the tank can be drained by means  
of a tap at the bottom of the tank.  
TAKING OUT OF OPERATION  
*
Switch to position "0". The fuel pump will  
stop and the flame will be extinguished once  
the oil in the combustion chamber is burnt.  
Remove the plug from the wall socket after the  
air intake fan has cooled down.  
If the burner is not to be used for a long  
period, combustion chamber, combustion dish,  
heat exchanger and tank should be cleaned  
carefully and protected against corrosion.  
*
*
The heater is delivered with a spare seal. If this  
seal is not replaced at the appropriate  
time, leakages causing soot formation may occur. The  
pedal assembly is equipped with an adjusting  
screw (2).  
If leakages occur or replacement of the seal is  
necessary, adjust this screw so that the bottom of the  
combustion chamber is set at more pres-sure against  
the chamber.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
┌────────────────────────────────────────────────┬─────────────────────────────────────────────────────────────┐  
LOCATION OF FAULTS  
├──────┬──────┬──────┬──────┬──────┬──────┬──────┤  
A B C D E F  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┤  
Flame Flame Soot HeaterHeaterOver- │  
extin-extin-forma-stops heats flow  
gui- gui- tion after insuf-secu- │  
shed shes in  
15 minfi-  
rity  
CHECK:  
imme- after burneror  
cient-is  
diate-the  
ly af-main and  
ter fan  
igni- has  
tion star- cham- │  
ted ber  
pot  
longerly  
period│  
filled│  
A. Electrical connection.  
B. Positioning of burner pan and burner ring.  
C. Flue installation, see page 1.  
with  
oil  
combus│  
tion  
├─────────────────────┬───────────────────────────────────────┤  
CAUSE SOLUTION  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┼─────────────────────┼───────────────────────────────────────┤  
1
7
5
Fuel tank is empty orClean filter.  
filter is obstructed.│  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┼─────────────────────┼───────────────────────────────────────┤  
2
2
Combustion air fan  
does not work.  
Check: if plug is in socket.  
Check: if fan motor is blocked.  
Check: electrical connections and  
thermostat.  
Check: air supply to the fan.  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┼─────────────────────┼───────────────────────────────────────┤  
3
5
3
Supply tube is ob-  
structed.  
Fuel flows into tank via return pipe, │  
clean fuel supply tube.  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┼─────────────────────┼───────────────────────────────────────┤  
4
4
Pump motor is not  
working.  
Check if pump shaft can be turned by  
hand. if not, remove and clean pump.  
Check if oil is too viscously: turn  
capacity regulator to position high.  
Check overflow security switch by mo- │  
ving the overflow tray a few times up │  
and down.  
Control switch is not pushed in or  
drawn out well.  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┼─────────────────────┼───────────────────────────────────────┤  
3
5
1
Overheating security Too much oil has been used for the  
has switched off  
ignition procedure.  
Check if main fan is not blocked and  
heater.  
(Reset this security working.  
by pushing the buttonCheck fan and electric connections.  
in the heater)  
Capacitor in switch box may be faulty.│  
Overflow security is filled with oil, │  
see F.  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┼─────────────────────┼───────────────────────────────────────┤  
1
1
Burner pan, burner  
Clean burner pan daily.  
ring and burner pot Clean burner pot and burner ring at  
have not been cleanedleast once a week.  
regularly.  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┼─────────────────────┼───────────────────────────────────────┤  
4
Poor connection be- Check packing and slide construction. │  
tween sliding panel Replace packing if necessary.  
with bottom and bur- Adjust set screw for spring pressure. │  
ner pot.  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┼─────────────────────┼───────────────────────────────────────┤  
4
Flame control thermo-Connect the two wires to the thermo-  
stat is defective.  
stat (attention, 220V) on nr. 5 and 12│  
If main blower starts to rotate, this │  
indicates a defective thermostat.  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┼─────────────────────┼───────────────────────────────────────┤  
1
3
3
2
2
Insufficient chimney Check flue for leakages.  
draught.  
Check if draught stabiliser is in  
Min. draught = 2 mmwkclosed position.  
Check flue for obstruction.  
Check flue height. Min. height is 5 m.│  
If there is more than 1 elbow or hori-│  
zontal pipe, the flue height must be  
extended.  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┼─────────────────────┼───────────────────────────────────────┤  
2
1
3
Fuel does not vapo- Viscosity of oil is too high. Mix with│  
rise sufficiently.  
After some time the  
overflow security  
paraffin or diesel oil.  
switches off heater. │  
├──────┼──────┼──────┼──────┼──────┼──────┼──────┼─────────────────────┼───────────────────────────────────────┤  
2
6
4
Tank contains water. Clean tank. Drain by means of drain  
plug beneath the tank.  
└──────┴──────┴──────┴──────┴──────┴──────┴──────┴─────────────────────┴───────────────────────────────────────┘  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data / Dane Techniczne / Технические данные  
Jednostka  
BTU/h  
kW  
WA 41 A  
WA 59 A  
Capacity min. bruto  
*
*
82.000  
123.000  
Wydajność minimalna brutto  
Тепловая мощность мин. брутто  
Capacity max. bruto  
Wydajność maksymalna brutto  
Тепловая мощность макс. брутто  
Fuel Consumption min.  
Zużycie paliwa min.  
Расход топлива мин.  
Fuel Consumption max.  
Zużycie paliwa max.  
24  
36  
BTU/h  
kW  
140.000  
41  
202.000  
59  
l/h  
l/h  
h
2,5  
3,8  
4,3  
6,2  
Расход топлива макс  
Burning duration with full tank min.  
Czas pracy na pełnym zbiorniku paliwa –  
wydajność min.  
Время работы с полным топливным баком –  
мин.мощность  
Burning duration with full tank max.  
h
Czas pracy na pełnym zbiorniku paliwa –  
wydajność max.  
Время работы с полным топливным баком –  
мин.мощность  
Heated Airflow  
Przepływ powietrza  
Нагретый воздушный поток  
Voltage  
Zasilanie sieciowe  
Электрическое снабжение  
Power Consumption  
Pobór mocy  
m3/h  
V/Hz  
A
3000  
3000  
220-240 / 50 220-240 / 50  
1,1  
1,2  
Потребляемый ток  
Flue Diameter  
Średnica rury kominowej  
mm  
150  
200  
Диаметр патрубка для отвода отработанных  
газов  
Width  
cm  
cm  
kg  
820  
820  
Szerokość  
Ширина  
Length  
Długość  
Длина  
Weight  
Waga  
880  
880  
135  
175  
Вес  
Height  
Wysokość  
Высота  
cm  
1.080  
1.290  
* Depending on viscosity  
* W zależności od lepkości  
* В зависимости от вязкости  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRING DIAGRAM / SCHEMAT ELEKTRYCZNY / ЭЛЕКТРИЧЕСКАЯ СХЕМА  
WA 41 A  
MBc  
BROWN  
BLUE  
CB  
10  
11  
12  
BLACK  
PT  
VT  
PM  
LT  
PL - yellow  
BLACK  
230V / 50Hz  
SUPPLY  
OP  
MB  
MS  
BROWN  
BLUE  
BLUE  
CB  
1
2
3
4
5
6
7
8
9
10  
11  
12  
1
2
3
4
5
6
7
8
9
10  
11  
12  
YELLOW  
GREEN  
BLUE  
BROWN  
RED  
BROWN  
ORANGE  
BLACK  
1
2
4
5
PURPLE  
S
C
MS : Microswitch for pump stop security  
MB : Main fan  
CB : Combustion air intake fan  
PL : Pilot light  
40.020.674/02  
PM : Pump motor  
OP : microswitch for Overflow Protection  
LT : Limit thermostat  
PT : Pump thermostat  
VT : Combustion air thermostat  
S
C
: Switch  
: Capacitor  
MBc : Main fan radial for C-kit (Ancillary)  
FL  
MS  
MB  
PM  
LT  
T
Flashlight /Lamka kontrolna / Сигнальный свет  
Microswitch / Mikrowyłącznik / Микропереключатель  
Main fan / Wentylator główny /Главный вентилятор  
Pump motor / Silnik pompy /Двигатель насоса  
Overheating thermostat / Termostat przegrzania /Термостат перегрева  
Thermostat / Termostat / Термостат  
CB  
PL  
OS  
S
Combustion air intake fan / Wentylator komory spalania /Вентилятор камеры сгорания  
Pilot light / Lamka kontrolna /Контрольный свет  
Overflow security / Zabezpieczenie przed przelewem/ Защита от перелива  
Switch / Przełącznik/ Переключатель  
C
Condensor / Kondensator /Конденсатор  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRING DIAGRAM / SCHEMAT ELEKTRYCZNY / ЭЛЕКТРИЧЕСКАЯ СХЕМА  
WA 59 A  
MBc  
BROWN  
BLUE  
CB  
10  
11  
12  
LOW  
BLACK  
HIGH  
PT  
VT  
PM  
PL - yellow  
LT  
BLACK  
230V / 50Hz  
SUPPLY  
PL - red  
OP  
MB  
RT  
MS  
BROWN  
BLUE  
10  
11  
11  
12  
12  
BLUE  
CB  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
11  
12  
BROWN  
YELLOW  
GREEN  
BLUE  
BROWN  
RED  
GREY  
1
2
4
5
PURPLE  
BLACK  
S
C
3
6
ORANGE  
MS : Microswitch for pump stop security  
MB : Main fan  
CB : Combustion air intake fan  
PL : Pilot light  
40.020.592/03  
PM : Pump motor  
OP : microswitch for Overflow Protection  
LT : Limit thermostat  
PT : Pump thermostat  
VT : Combustion air thermostat  
S
C
: Switch  
: Capacitor  
MBc : Main fan radial for C-kit (Ancillary)  
RT : Room thermostat (Accessory for AT-500)  
FL  
MS  
MB  
PM  
LT  
T
Flashlight /Lamka kontrolna / Сигнальный свет  
Microswitch / Mikrowyłącznik / Микропереключатель  
Main fan / Wentylator główny /Главный вентилятор  
Pump motor / Silnik pompy /Двигатель насоса  
Overheating thermostat / Termostat przegrzania /Термостат перегрева  
Thermostat / Termostat / Термостат  
CB  
PL  
OS  
S
Combustion air intake fan / Wentylator komory spalania /Вентилятор камеры сгорания  
Pilot light / Lamka kontrolna /Контрольный свет  
Overflow security / Zabezpieczenie przed przelewem/ Защита от перелива  
Switch / Przełącznik/ Переключатель  
C
Condensor / Kondensator /Конденсатор  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIVERSAL OIL HEATERS – WA 41  
Pos.  
Code NR  
Description  
1
2
3
S/R  
S/R  
S/R  
SIDE PLATE LEFT  
SIDE PLATE RIGHT  
BACK PANEL  
4
5
6
7
S/R  
S/R  
S/R  
S/R  
COOLING PLATE  
SLIDING PANEL  
BOTTOM PANEL  
TOP LID  
8
S/R  
FRAME  
9
S/R  
S/R  
S/R  
SIDE PANEL LEFT  
SIDE PANEL RIGHT  
TOP LID OF CONTROL PANEL  
TANK  
BLOWING GRILL  
VAPORIZING SECTION  
SLIDER  
BOTTOM  
COMBUSTION DISH  
BURNER RING  
HEAT SHIELD WA 41A  
BAFFLE PLATE  
COMBUSTION CHAMBER  
COVER COMBUSTION CHAMBER  
LOCKING BAR  
HEAT EXCHANGER  
THERMOSTAT  
OVERHEAT THERMOSTAT  
LEVER  
10  
11  
12  
13  
14  
15  
16  
17  
18  
18a  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
49a  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
4506.137  
S/R  
4506.141  
S/R  
4506.138  
4506.021  
4506.043  
4506.044  
4506.133  
4506.136  
4506.130  
4506.125  
4506.140  
4506.019  
4506.020  
4506.126  
S/R  
4506.006  
S/R  
4506.005  
4506.123  
4506.134  
S/R  
LOCKING DEVICE  
FUEL PUMP  
FUEL PUMP SUPPORT  
FILTER  
DRIVE SHAFT  
FUEL TANK FILTER  
3-WAY CONNECTOR  
SUPPLY PIPE  
CONNECTOR  
DRIP FEED PIPE  
RETURN LINE  
PUMP MOTOR  
SWITCH  
PILOT LIGHT RED  
CONTROL PANEL  
AIR INLET PLATE  
CAPACITOR  
FAN HOUSING  
MOTOR CLIP  
PROTECTION GRILL  
MOTOR  
COMBUSTION FAN  
MAIN FAN  
PROTECTION GRILL  
PILOT LIGHT YELLOW  
MICRO SWITCH  
OVERFLOW TRAY  
COMPRESION SPRING  
SEALING CORD  
SEALING CORD  
THERMOSTAT BRACKET  
T-PIECE  
CROWN STRIP  
COOLING PLATE  
MICRO SWITCH PUMP STOP  
SHOWEL  
S/R  
4506.131  
4506.118  
4506.122  
4506.003  
4506.121  
N/A  
S/R  
S/R  
4506.119  
S/R  
S/R  
S/R  
4506.135  
4506.116  
4506.139  
4506.132  
4506.117  
4506.202  
4506.124  
4506.128  
4506.120  
4506.129  
S/R  
4506.002  
4506.115  
4506.127  
S/R  
S/R  
S/R – Parts available by special request only  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIVERSAL OIL HEATERS – WA 59  
Pos.  
Code NR  
Description  
1
2
3
S/R  
S/R  
S/R  
SIDE PLATE LEFT  
SIDE PLATE RIGHT  
BACK PANEL  
4
5
6
7
S/R  
S/R  
S/R  
S/R  
COOLING PLATE  
SLIDING PANEL  
BOTTOM PANEL  
TOP LID  
8
S/R  
FRAME  
9
S/R  
S/R  
S/R  
SIDE PANEL LEFT  
SIDE PANEL RIGHT  
TOP LID OF CONTROL PANEL  
TANK  
BLOWING GRILL  
VAPORIZING SECTION  
SLIDER  
BOTTOM  
COMBUSTION DISH  
BURNER RING  
BAFFLE PLATE  
COMBUSTION CHAMBER  
COVER COMBUSTION CHAMBER  
LOCKING BAR  
HEAT EXCHANGER  
THERMOSTAT  
OVERHEAT THERMOSTAT  
LEVER  
LOCKING DEVICE  
FUEL PUMP  
FUEL PUMP SUPPORT  
FILTER  
DRIVE SHAFT  
FUEL TANK FILTER  
3-WAY CONNECTOR  
SUPPLY PIPE  
CONNECTOR  
DRIP FEED PIPE  
RETURN LINE  
PUMP MOTOR  
SWITCH  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
49a  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
4506.137  
S/R  
4506.148  
S/R  
4506.138  
4506.021  
4506.149  
4506.133  
4506.145  
4506.130  
4506.125  
4506.147  
4506.019  
4506.020  
4506.126  
S/R  
4506.143  
S/R  
4506.005  
4506.123  
4506.134  
S/R  
S/R  
4506.131  
4506.118  
4506.122  
4506.004  
4506.058  
N/A  
S/R  
S/R  
4506.119  
S/R  
PILOT LIGHT RED  
CONTROL PANEL  
AIR INLET PLATE  
CAPACITOR  
FAN HOUSING  
MOTOR CLIP  
PROTECTION GRILL  
MOTOR  
COMBUSTION FAN  
MAIN FAN  
S/R  
S/R  
4506.135  
4506.116  
4506.139  
4506.132  
4506.117  
4506.202  
4506.124  
4506.128  
4506.120  
4506.129  
S/R  
GRILL  
PILOT LIGHT YELLOW  
MICRO SWITCH  
OVERFLOW TRAY  
COMPRESION SPRING  
SEALING CORD  
SEALING CORD  
THERMOSTAT BRACKET  
T-PIECE  
CROWN STRIP  
COOLING PLATE  
MICRO SWITCH PUMP STOP  
SHOWEL  
4506.144  
4506.115  
4506.127  
S/R  
S/R  
S/R – Parts available by special request only  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Kuppersbusch USA Oven EEB 96000 User Manual
Lenoxx Electronics Furnace G41UF User Manual
Lenoxx Electronics Heat Pump HP32 Series User Manual
LG Electronics Microwave Oven MS 207YS User Manual
Lincoln Electric Welder SVM156 A User Manual
Lowrance electronic GPS Receiver LMS 330C User Manual
LumiSource Video Game Furniture A44 User Manual
Maxtor Computer Drive 3100 User Manual
McCulloch Trimmer 115249726 User Manual
Melissa Blender 246 033 User Manual