Maretron GPS Receiver BHW100 User Manual

Installation Instructions  
BHW100 Bilge High Water Detector  
Instructions  
Please follow these instructions to connect the BHW100 to the NMEA 2000 network via a Maretron SIM100  
Switch Indicator Module. The wiring diagram appears in Figure 1 on the reverse of this page. The diagram shows  
a connection to channel #1, but connections to other channels are similar.  
1. The BHW100 cable contains one blue and one brown wire. Connect the brown wire to a free switch  
channel “A” terminal on the SIM100. The example in Figure 1 shows the detector connected to switch  
channel 1 with the brown wire connected to “SW1A”.  
2. Connect the blue wire to the corresponding “SWxB” terminal. The example in Figure 1 shows the detector  
connected to switch channel 1 with the blue wire connected to “SW1B”.  
NOTE: The brown wire from the BHW100 must be connected to the “A” terminal of the switch  
channel and the blue wire must be connected to the “B” terminal of the switch channel. If these  
wires are reversed, the detector will not operate properly.  
3. Use a Maretron DSM250 display (firmware 1.3.5 or higher), the DSM250 viewing function of the Maretron  
N2KAnalyzer software, or other Maretron display product capable of configuring the SIM100 to set the  
switch channel mode (indicated as “Channel #x Mode” on the DSM250) to “End of Line Resistor”. For this  
example, you would set “Channel #1 Mode” to “End of Line Resistor”.  
4. With the BHW100 out of water, supply power to the NMEA 2000 network and verify that the switch  
channel indicates the “off” (normal) state using Maretron N2KView software, N2KAnalyzer, or other  
product capable of displaying switch indicator state.  
5. Immerse the BHW100 in water and verify that the switch channel indicates an “on” (alarm) state during  
the test.  
6. Disconnect either the brown or blue alarm wire from the SIM100 and verify that the switch channel  
indicates an “error” state.  
7. Reconnect the wire after the test and verify that the switch channel indicates an “off” (normal) state.  
8. Install the BHW100 to the side of the bilge so that the molded-in “target” on the side of the unit is visible,  
and so that the center of the target is at the height of the water level at which you want the bilge water  
alarm to occur.  
(continued on reverse)  
Copyright © 2011 Maretron, LLP All Rights Reserved  
P/N: M001804 Rev.1.2 1/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Learning Resources Baby Toy LER 7252 User Manual
LevelOne Switch GSW 4870TGX User Manual
Majestic Appliances Indoor Fireplace Majestic Oak Series User Manual
Maxon Telecom Radio SP 300 Series Synthesized Scanning Radio User Manual
Maytag Range W10234649A User Manual
McCulloch Pressure Washer 7096 140A02 User Manual
McCulloch Pressure Washer 7096 H18A01 User Manual
Melissa Microwave Oven 653 096 User Manual
Metra Electronics Car Amplifier 70 6506 User Manual
Metz Stereo Receiver 55TH34 VT User Manual