INTRODUCTION
THANK YOU!...
for choosing the Manley Euro 100 Stereo Amplifier. Designed by David Manley, the Manley Euro 100 Stereo
Amplifier uses only the best available components, with the shortest and cleanest signal path possible, and with the
use of our own milling equipment we can provide you with a amplifier that looks as good as it sounds. For this
amplifier design, we have chosen an interesting Russian military tube, the GammaY50. The circuit and the
components used have been chosen carefully after years of development and refinement for reliability, constancy
and most importanly, musical, accurate, and emotional delivery of the sound. The circuit topology is similar to
other designs in the MANLEY range. This amplifier is configured for ULTRALINEAR or "partial-triode"
operation which achieves the seductive quality of triode operation without the inefficiency and sacrifice in power
of triode operation. We emphasize big, beefy resevoir capacitors in the high voltage supplies giving plenty of
instant energy for dynamic performance of transient peaks and bass performance which often exceeds that of rival
solid-state amplifiers. We run high voltages on the plates of the output tubes and are thus able to run them at lower
current which will result in longer life for the output tubes. Each output tube has its own bias adjust, and the
procedure for adjusting each tube's current draw is described in this manual. The output transformer has been
factory set in series-parallel for an optimum 5 ohm load which will drive most speakers. Other output impedances
can be achieved by changing the configuration of the transformer secondary. Please contact us at the factory should
you need to do this.
Thank you again, and please enjoy!
GENERAL NOTES
LOCATION & VENTILATION
The Manley Stereo 100 Amplifier must be installed in a stable location with ample ventilation. Allow a minimum
of 2 inches of clearance on the top and sides of the amplifiers, such that constant movement of air can flow. Do
not place amplifiers directly on high pile carpet or any other surface that will block the ventilation holes
underneath the amplifiers. If you have small children or pets, you should consider placing the amplifiers out of
reach or using the optional cages (covers) available as an option to prevent damage to the amplifier or damage to
your small children or pets by the amplifier as the tubes do get hot during operation.
WATER & MOISTURE
As with any electrical equipment, this amplifier should not be used near water or moisture. If liquid enters the
amplifier, it must be immediately returned to your deal for servicing.
SERVICING
The user should not attempt to service the amplifier beyond that described in the owner's manual. Refer all
servicing other than biasing and tube replacement to Manley Laboratories
SPECIAL NOTES
Tubes may become loose during transit. Straighten and press down each tube before plugging the amplifier into
the mains socket. Furthermore, NEVER touch the tubes after the amplifier has been switched on, the tubes become
very hot during operation and should only be handled after the power has been turned off and the tubes have
cooled.
WARNING!
!
TO PREVENT THE RISK OF ELECTRIC SHOCK
DO NOT OPEN THE CABINET
REFER SERVICING TO
QUALIFIED PERSONEL
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINS CONNECTIONS
Your amplifier has been factory set to the correct mains voltage for your country. The voltage
setting is marked on the serial badge, located on the rear panel. Check that this complies with
your local supply.
Export units for certain markets have a moulded mains plug fitted to comply with local require-
ments. If your unit does not have a plug fitted the coloured wires should be connected to the
appropriate plug terminals in accordance with the following code.
GREEN/YELLOW
BLUE
BROWN
EARTH
NEUTRAL terminal
LIVE terminal
terminal
As the colours of the wires in the mains lead may not correspond with the coloured marking
identifying the terminals in your plug proceed as follows;
The wire which is coloured GREEN/YELLOW must be connected to the terminal in the plug
which is marked by the letter E or by the safety earth symbol or coloured GREEN or GREEN
and YELLOW.
The wire which is coloured BLUE must be connected to the terminal in the plug which is
marked by the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal in the plug which is
marked by the letter L or coloured RED.
DO NOT CONNECT/SWITCH ON THE MAINS SUPPLY UNTIL ALL OTHER CON-
NECTIONS HAVE BEEN MADE.
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTING YOUR AMPLIFIER
Setting up your amplifier is rather easy.
1. Connect all source components (turntable, CD, Tuner, Tape DAT, etc.) to your
preamplifier.
2. Connect the interconnects from the output of the preamplifier or switching center
to the RCA input on the top rear of the amplifier.
3. Connect the hot or "+" speaker cable to the red binding post and the common or "-
" speaker cable to the black binding post (See diagarm 2). Ensure that the other
end of the cable is connected correctly to the speaker. Tighten the binding posts
by hand. If you use a nut-driver (3/8") do not over-tighten the posts or you may
breaak the connection inside the amplifier.
4. Ensure that the "mains" switch on the front panel is in the "off" or "0" position.
5. Turn on Preamplifier and any source components you plan to use.
6. Plug amplifier into wall outlet.
7. Turn on the amplifier and allow it a minute or so to 'warm up' before playing any
audio signal.
8. Turn up the volume and enjoy.
Download from Www.Somanuals.com. All Manuals Search And Download.
BIAS PROCEDURES
The Manley Euro Stereo 100 is a fixed bias system that requires very little attention. If you wish
to adjust or check the bias, follow the following steps.
1.
On diagram 2, which depicts the top panel of the amplifier, you can see 4 black tip jacks
and 1 green tip jack. To measure the current draw of each output tube place the positive probe
(red) into the black tip jack for the tube you wish to measure and the negative probe (black) in
the green (GROUND) tip jack and set the meter to read 'millivolts'.
2.
Each of the four (4) output tubes can have its own bias adjusted by altering its own bias
adjust pot. On diagram 2, you can see the numbering sequence for the 4 output tubes, the
corresponding tip jack (measurement point) and bias adjust pot.
3.
The first step to setting the bias is to turn on the amplifier and ensure that there is zero
signal input. Also, leave your loadspeakers connected as these provide an ideal load on the
output. It is recommended that you leave the amplifier on long enough to ensure that the tubes
have reached their stable current draw.
5.
Place the probes in the first black tip jack (negative probes remains in the green tip jack
for whole biasing proceedure) and adjust the first bias trip pot (see diagram 2) until you measure
300 to 350 mV. Since you are measuring across a 10 ohm cathode resistor, this would
correspond to a 30 to 35 mA bias current.
6.
If you are unable to bring the bias voltage down to 300 to 350 mV on any tube then we
recommend that the tube be carefully watched or replaced.
7.
Follow step five with the remaining tubes. Once they are all set, your amplifier should
Whenever replacing an output tube, or when retubing the unit, use
be in perfect operation.
tubes of the same type and quality as was fit by the factory. Watch and adjust the bias for the
specific output tube or tubes you are replacing as soon as you turn on the amplifier, then check
again after a half hour, and again in a few hours. Should you have any questions, or wish to
purchase approved tubes from us here at Manley Labs, please do not hestitate to call.
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATIONAL NOTES
SWITCHING ON
The power switch is located on the lower left hand corner of the front panel. Push the top of the
rocker switch (1) to turn on the amplifier and the bottom of the rocker to turn off the amplifier.
The LED on the right side of the front panel will illuminate indicating that the amplifier is
operating.
RUNNING
It is not recommended that you leave your amplifier permanently switched on. This only wastes
electricity and tube life. Your amplifier has solid state rectification and reaches peak operating
condition in approximately 30 minutes.
TUBE LIFE
As with all tubes, their quality degrades with age. This is due to cathode emission, a natural
process found in all tubes. We recommend that you have your amplifier checked every 3-4
years, depending on usage, usually the amplifier will require re-tubing after this time has
elapsed.
PANEL LAMP
The lamp which illuminates the front panel insert is easily replacable should it ever burn out. To
replace it use only the same type with the same or greater voltage rating. In these amplifiers, the
lamp is a FUSE LAMP STYLE 8V 0.15mA. Dimensions are 1/4" x 1 1/4". To replace the
lamp, first turn off the amplifier and unplug the power cord!
Remove the bottom cover and locate the lamp holder which sets behind the pront panel insert.
Do not touch any other components inside the amplifier as high voltages may be present even
after the amplifier is unplugged, sometimes for weeks! Carefully pry out the old lamp from the
clips and firmly replace with the new lamp of the same type and rating. Replace the bottom
cover after you are through.
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
Vacuum Tubes:
4 x GY50 (Output), 2 x 6350 (Driver), 2 x 12AT7 (Input)
Output Power
88 Watts @1Khz 1.5%THD, into 5 ohms
Frequency Response, +/- .5 dB
Input Sensitivity
10 Hz - 35 KHz
800 mV
Input Impedance
100 KOhm
5 Ohm
Load Impedance
S/N Ratio @350W
Power Consumption
-80 dB
220 Watts
420 Watts
Quiescent
Full Power
Mains Fuse
B+ Fuse
100, 110, 120V
220, 240 V
6 A (Slo-Blo)
3 A (Slo-Blo)
1A
Dimensions
Weight
W=19, D=13, H=7 inches
46 lbs
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY
All Manley Laboratories equipment is covered by a limited warranty against defects in materials
andworkmanshipforaperiodof90daysfromdateofpurchasetotheoriginalpurchaseronly.A
furtheroptionallimited5yearwarrantyisavailabletotheoriginalpurchaseruponproper
registrationofownershipwithin30daysofdateoffirstpurchase.
Properregistrationismadebyfillingoutandreturningtothefactorythewarrantycardattachedto
this general warranty statement, along with a copy of the original sales receipt as proof of the
originaldateofpurchase. Only1cardisissuedwitheachunit, andtheserialnumberisalready
recordedonit.
Ifthewarrantyregistrationcardhasalreadybeenremovedthenthisisnotanewunit, andis
therefore not warranted by the factory. If you believe this to be a new unit then please contact the
factorywiththedetailsofpurchase.
Thiswarrantyisprovidedbythedealerwheretheunitwaspurchased,andbyManleyLaboratories,
Inc. Underthetermsofthewarrantydefectivepartswillberepairedorreplacedwithoutcharge,
exceptingthecostoftubes.Nowarrantyisofferedontubes,unless:
1.aManleyLaboratoriespreamplifierisusedwithaManleyLaboratories amplifier,and
2. thewarrantyregistrationcardisfilledout.
In such a case a 6 month warranty on tubes is available with the correct recording of the serial
numberofthepreamplifieronyourwarrantyregistrationcard.
IfaManleyLaboratories productfailstomeettheabovewarranty,thenthepurchaser'ssole
remedyshallbetoreturntheproducttoManleyLaboratories, wherethedefectwillberepaired
withoutchargeforpartsandlabour.Theproductwillthenbereturnedviaprepaid,insuredfreight,
methodandcarriertobedeterminedsolelybyManleyLaboratories.Allreturnstothefactorymust
beintheoriginalpacking,(newpackingwillbesuppliedfornochargeifneeded),accompaniedby
awrittendescriptionofthedefect,andmustbeshippedtoManleyLaboratoriesviainsuredfreight
atthecustomer'sownexpense.Chargesforunauthorizedserviceandtransportationcostsarenot
reimbursableunderthiswarranty,andallwarrantees,expressorimplied,becomenullandvoid
wheretheproducthasbeendamagedbymisuse,accident,neglect,modification,tamperingor
unauthorizedalterationbyanyoneotherthanManleyLaboratories.
Thewarrantorassumesnoliabilityforpropertydamageoranyotherincidentalorconsequental
damagewhatsoeverwhichmayresultfromfailureofthisproduct.Anyandallwarranteesof
merchantabilityandfitnessimpliedbylawarelimitedtothedurationoftheexpressedwarranty.
AllwarranteesapplyonlytoManleyLaboratoriesproductspurchasedandusedintheUSA.
Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts, sotheabove
limitations may not apply to you. Some states do not allow the exclusion or limitation of incidental
orconsequentialdamges,sotheaboveexclusionmaynotapplytoyou.
Thiswarrantygivesyouspecificlegalrightsandyoumayalsohaveotherrightswhichvaryfrom
state to state.
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTYREGISTRATION
We ask that you please fill out this registration form and send the bottom half to:
MANLEY LABORATORIES
REGISTRATION DEPARTMENT
13880 MAGNOLIA AVE.
CHINO CA, 91710
Registration entitles you to product support, full warranty benefits, and notice of product
enhancements and upgrades. You MUST complete and return the following to validate your
warranty and registration. Thank you again for choosing to use Manley Laboratories.
MODEL ____________________ SERIAL No. ______________________
PURCHASE DATE ______________ SUPPLIER ______________________
--------------------------------------------------------------------------------------------------------
PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES
MODEL ____________________
SERIAL No. ______________________
PURCHASE DATE ______________ SUPPLIER _______________________
NAME OF OWNER _______________________________________________
ADDRESS ______________________________________________________
CITY, STATE, ZIP________________________________________________
TELEPHONE NUMBER ___________________________________________
Serial #'s of Associated Manley Laboratories Equipment ___________________
________________________________________________________________
Download from Www.Somanuals.com. All Manuals Search And Download.
|