Electric
Fireplace
Model
HE32EF
Installation Instructions & Homeowner's Manual
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY,
AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY
OF THIS OR ANY OTHER APPLIANCE.
C
US
™
The Vermont Castings
Majestic Products Company
410 Admiral Blvd. • Mississauga, Ontario • Canada L5T 2N6
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
10003395
07/01 Rev.0
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
GENERAL
1 . Read all instructions before using this appliance.
15. To prevent a possible fire, do not block air intakes or
exhaust in any manner. Do not use on soft surfaces,
like a bed, where openings may become blocked.
2. This appliance is hot when in use. To avoid burns, do
not let bare skin touch hot surfaces. If provided, use
handles when moving this appliance. Keep combus-
tible materials, such as furniture, pillows, bedding,
papers, clothes and curtains at least 3 feet (1m) from
the front of this appliance.
16. This appliance has hot and arcing or sparking parts
inside. Do not use it in areas where gasoline, paint or
flammable liquids are used or stored. This fireplace
should not be used as a drying rack for clothing, nor
should Christmas stockings or decorations be hung in
the area of it.
3. CAUTION: Extreme caution is necessary when any
heater is used by or near children or invalids and
whenever the heater is left operating and unat-
tended.
17. Use this appliance only as described in this manual.
Any other use not recommended by the manufacturer
may cause fire, electric shock or injury to persons.
4. If possible, always unplug this appliance when not in
use.
18. Avoid the use of an extension cord because the
extension cord may overheat and cause a risk of fire.
However, if you have to use an extension cord, the
cord shall be No. 16 AWG minimum size and rated not
less than 2025 Watts. The extension cord must be a
three wire cord with grounding type plug and cord
connection.
5. Do not operate any heater with a damaged cord or plug
or after the appliance malfunctions, or if it has been
dropped or damaged in any manner.
6. Any repairs to this fireplace should be carried out by a
qualified service person.
19. SAVE THESE INSTRUCTIONS.
7. Under no circumstances should this fireplace be modi-
fied. Parts having to be removed for servicing must be
replaced prior to operating this fireplace again.
LOCATING YOUR VERMONT CASTINGS
MAJESTIC PRODUCTS COMPANY
ELECTRIC FIREPLACE
8. Do not use outdoors.
9. This heater is not intended for use in bathrooms,
laundry areas and similar indoor locations. Never
locate this appliance where it may fall into a bathtub or
other water container.
Your new fireplace may be installed into an existing
masonry fireplace. This unit may also be built into new
or existing construction.
10. Do not run cord under carpeting. Do not cover cord
withthrowrugs,runnersorthelike. Arrangecordaway
from traffic areas and where it will not be tripped over.
When choosing a location for your new fireplace, ensure
that the general instructions are followed. Also, for best
effect install the fireplace out of direct sunlight.
11. To disconnect this appliance, turn controls to the off
position, then remove plug from outlet.
A zero clearance kit is NOT required
for this unit.
12. Connect to properly grounded outlets only.
13. This appliance, when installed must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the current CSA C22.1
Canadian Electrical Code or for U.S.A. installations
follow local codes and the National Electrical Code,
ANSI/NFPA NO. 70.
ELECTRICAL SPECIFICATIONS
Voltage _____________ 120VAC, 60Hz
Total Amps ______________12.5 Amps
Total Watts _____________ 1500 Watts
Heater Rating ___________ 1300 Watts
14. Do not insert or allow foreign objects to enter any
ventilation or exhaust opening as this may cause an
electric shock or fire, or damage the appliance.
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
FIREPLACE DIMENSIONS
B
F
D
A
E
G
H
C
MINIMUM FIREPLACE OPENING
T
Q
U
S
R
R - Fireplace opening width
Q - Fireplace opening height
S - Firebox width at depth(T)
T - Firebox depth at back height (U)
U - Height at depth
HE32EF
A1
265/8"
383/8"
29"
676 mm
975 mm
737 mm
B1
A2
B2
A3
B3
A4
B4
A5
B5
C
T
R
I
4115/16" 1065 mm
1= SS or SSD Trim
2= SL or SLD Trim
3= SXL Trim
4= BSL Trim
5= BXL Trim
33"
838 mm
1118 mm
712 mm
1041 mm
775 mm
1171 mm
730 mm
476 mm
292 mm
330 mm
558 mm
508 mm
533 mm
711 mm
433 mm
289 mm
514 mm
M
44"
28"
407/8"
301/2"
46"
283/4"
183/4"
111/2"
13"
F
I
D
R
E
P
L
A
C
E
E
F
G
22"
H
20"
Q
21"
M
I
N
I
M
U
M
O
P
E
N
I
N
G
R
28"
S
19"
T
113/4"
201/4"
U
Fig. 1
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
FRAMING & FINISHING
MANTELS
When the fireplace is being installed into a woodburning
fireplace the minimum the mantel can be above the fire-
place is governed by local building codes applicable to
woodburning fireplaces. Consult local authorities having
jurisdiction for these clearances.
Before deciding on the frame dimensions and finishing
materialsitisimportanttoconsiderthefinisheddimensions
of the chosen fireplace trim kit (see options section of this
manual).
The underside of the mantel will get quite
warm. Use only finishes which are heat
resistant and do not discolour.
This information is required at this stage to ensure a
satisfactory finish when the trim kit is installed.
The use of wall paper adjacent to this fireplace
is not recommended, as the high heat given off
by this fireplace may adversely effect the bind-
ers in the adhesive used to apply the wallpa-
per.
The fitting of the bay window kit does not
affect the dimensions or reference points in
the mantel chart.
RAISED
CLEARANCE TO COMBUSTIBLES
Sides ....... 0 mm/0 inches
Sides ....... 0mm/0 inches
Floor........ 0 mm/0 inches
Top.......... 0 mm/0 inches
Fig. 2
MANTEL CHART
Ref. Mantel & Leg Ref.
Shelf Depth
Mantel From
Top of Comb. From Side of Comb.
Chamber
Mantel Leg from
FINAL FINISHING
Chamber
V
W
X
10" (254 mm)
8" (203 mm)
6" (152 mm)
4" (101 mm)
2" ( 51 mm)
A
B
C
D
E
19" (305 mm)
10" (254mm)
Non-combustible materials such as brick and tile can be
extended over the face of the unit (Do not cover louvres
or glass door). If a Trim Kit is going to be installed, brick
and tile will have to be installed flush with the side of this
appliance.
17" (254 mm)
15" (203 mm)
13" (152 mm)
11" (101 mm)
8" (203mm)
6" (152mm)
4" (101mm)
2" (51mm)
Y
Z
V
HEARTH
W
A hearth is not mandatory but it is recommended for
aesthetic purposes. We recommend a non-combustible
hearth which does not obstruct louvre opening.
X
Y
WALL
A
B
C
D
Cold climate installation recommendation:
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be insulated
to conform to applicable insulation codes.
Z
E
TOP
LOUVRE
OPENING
FIREBOX TOP
FRONT
GLASS
FIREPLACE
SIDE VIEW
OPTIONAL
HEARTH
Fig. 3
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION OF LOGS
ELECTRICAL CONNECTION
1. Turn off power to the unit.
A 15 AMP, 120 Volt, 60 Hz circuit with a properly grounded
outlet is required. Preferably, the fireplace will be on a
dedicated circuit as other appliances on the same circuit
may cause the circuit breaker to trip or the fuse to blow
when the heater is in operation. The unit comes standard
with a 6 ft. (1828mm) long three wire cord, exiting the right
side of the fireplace. Plan the installation to avoid the use
of an extension cord. If an extension cord must be used,
it must be a minimum 16AWG, three wire with grounding
type plug and connector and rated not less than 2025
Watts.
2. Remove front glass (See "Glass Removal" section).
3. The log bottom is shipped in place. No adjustment is
necessary.
A new electrical outlet can be installed inside the frame
construciton, if permitted by local codes.
Electrical outlet wiring must comply with
local building codes and other applicable
regulationstoreducetheriskoffire,electrical
shock and injury to persons.
HE32EF / DEF33 *
Fig. 4
* HE32EF / DEF33 is a unitized log set.
Do not use this fireplace if any part of it has
been under water. Immediately call a
qualified service technician to inspect the
fireplaceandreplaceanypartoftheelectrical
system which has been under water.
CERAMIC REFRACTORY INSTALLATION
Hard (Direct) Wire Connection
1. Remove the glass assembly.
If desired, a qualified electrician may remove the cord
conection and wire this unit directly to the household
wiring.
2. Slide refractory panels on either side of the firebox
between firebox side and the upper lintel baffle.
3. Push panels against firebox side. If desired, secure
the panels to the sides of the firebox with some
adhesive, such as silicone.
Any electrical re-wiring of this appliance
must be done by a qualified electrician.
4. Replace glass frame and upper louvre panel.
WARNING: This fireplace comes with an
optionalmanualcircuit breakerreset beside
the On/Off switch. In case the fireplace is
not operating check the circuit breaker and
reset the button at the breaker. If the
fireplace is still not operating immediately
callaqualifiedservicetechniciantoinspect
the fireplace.
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE INSTRUCTIONS
Disconnect power before attempting any
maintenance or cleaning to reduce the risk
of fire, electrical shock or personal injury.
GLASS INFORMATION
1. Under no circumstances should this product be
operated with missing or broken glass.
2. Do not strike or slam the glass.
LOUVRE REMOVAL
3. Do not use abrasive cleaners to clean the glass.
4. This product uses tempered glass. Replacement of
the glass with gasket as supplied by the manufac-
turer should be done by a qualified service person.
To remove top louvre pull louvre up and then lift out.
See Figure 5.
2.
REPLACING LIGHT BULBS
LOUVRE
1.
This fireplace uses three (3) clear 120 Volt, 60 Watt, E-
12 and one (1) clear 120 Volt, 5 Watt, E-12 socket base
light bulbs. (Small base, chandelier candle type). Three
(3) of the lights are located under the ember bed of the
unit. The fourth (4) light is found at the top of the firebox
above the log set. For convenience, if one of the bulbs
burns out, it may be a good idea to replace all of the light
bulbs.
GLASS
PANEL
Fig. 5
Do not exceed 60 Watts per bulb. Use of
higher rated bulbs may result in a fire,
causing property damage, personal injury
or loss of life.
GLASS FRAME REMOVAL
1
.
Remove the top louvre. (See "Louvre Removal" section)
1. Turn off power to the unit.
2. Open the access door.
2. Let fireplace cool if it has been operating.
3. Remove top louvre. (See Louvre Removal).
4. Remove glass door. (See Glass Frame Removal).
5. Remove the two screws securing the ember bed in
position. One screw is located on either side of the
ember bed near the front.
3. Remove two machine screws from the bottom of glass
frame.
4. Lift up and unhook glass frame at the top.
Before remounting glass frame, brass trim
must be installed. See instructions in
"Frame Mounting" section.
6. Examine the bulbs to determine which bulbs need to
be replaced.
7. While holding the socket, unscrew the defective
bulb(s).
8. Install the new light bulb(s) by screwing in while
holding the socket.
9. Reinstall ember bed, log set, glass door and top
louvre.
GLASS FRAME
SCREWS
MACHINE SCREWS
OPEN ACCESS DOOR
Fig. 6
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING BRASS TRIM
MAINTENANCE OF MOTORS
Clean the brass trim using a soft cloth, slightly dampened
with lemon oil and buff with a clean soft cloth. Do NOT use
brass polish or household cleaners as these products will
damage the brass trim. Lemon oil can be obtained at
supermarkets or hardware stores.
The motors used on the fan and the drum assembly are
prelubricated for extended bearing life and require no
further lubrication. However, periodic cleaning/vacuuming
of the fan/heater is recommended.
Make sure that the power is turned off
before proceeding.
ELECTRICAL DIAGRAM
Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and
local codes.
If repairing or replacing any electrical component or wiring, the original wire routing, colour coding
and securing locations must be followed.
2
RED
FAN
MOTOR
1WHITE
18
FAN
MOTOR
17
2
17
3
RED
HEATER ELEMENT
2
RED
18
1WHITE
LIMIT
8
WHITE
AIR WHEEL FAN/HEATER WIRING DIAGRAM
WHITE
WHITE
HEATER ELEMENT
3
10
11
19
7 WHITE
6 BLACK
11
9
DRUM
MOTOR
4
11
5
11
10
11
10
5
12
POTENTIOMETER
5
WHITE
16
7
WHITE
8
WHITE
4
BLACK
9 BLACK
SPEED CONTROL
15
T' STAT
SWITCH
1
BLACK
6
7
BLACK
WHITE
SWITCH
BLACK
3
RED
8
2
14
13
6
BLACK
BREAKER CIRCUIT
(OPTIONAL)
Component Identification:
11. Nylon Cable Tie 3-7/8"
12. Potentiometer
13. Dimmer SwitchRotary Assy
14. Thermostat
Component Identification:
Wiring Colour Code:
WH= White
BL = Black
1. CFM-Majestic Factory Wire Required
2. Plug 0.093" Pin & Socket
3. Light Socket Assembly
4. Light Socket w/ Wiring Assembly
5. Light Bulb
RE = Red
15. Switch
16. Speed Control
17. Receptacle Pin & Socket
18. Fan/Heater
6. Cord Power
7. Strain Relief
8. Breaker Circuit Manual Reset
9. Motor Variable Speed 12 VDC
10. Grommet 7/8
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
Thecontrolcompartmentislocatedbehindthelowerlouvre
2. HEATER CONTROL
panel. To access the controls, simply flip down the lower
louvre panel. To locate the position of each control de-
scribed below, refer to Fig. 7.
TheHeaterControlactstoturntheheateronandoffaswell
as setting the comfort level in the room. Turning the knob
clockwise from the off position will place the heater into
operation. The further the knob is rotated clockwise, the
higher the set point temperature. Turning the knob
counterclockwise will lower the set point temperature.
Turning it all the way counterclockwise will turn the heater
function off.
1. MAIN ON/OFF SWITCH
The On/Off switch supplies power to all of the functions of
the fireplace. This is an illuminated switch which normally
will light up when in the "On/Off" position.
During any service of this appliance, the
power to the unit must be turned off. It is
not acceptable to use the "On/Off" switch
to meet this requirement.
3. LOG ILLUMINATION CONTROL
The On/Off switch controls the light located above the log
set.
4. FLAME SPEED CONTROL
Turn the flame speed control knob to increase or decrease
the flame speed as desired.
CONTROL PANEL
4
1
2
3
Voir les instructions d’installation pour
des details sur le service.
AVERTISSEMENT: Debrancher la source
d’alimentation avant le service.
AVERTISSEMENT: Risque d’incendie,
veiller a ce que les cordons electriques,
tentures et autres textiles domestiques
soient a au moins 3 pieds (0,9m) de
I’avant de I’appareil de chauffage.
See Installation Instructions for service
details.
WARNING: Disconnect Power Before
Servicing.
WARNING: Risk of fire, keep electrical
cords, draping, and other furnishings at
least 3 feet (0.9m) from the front of the
heater.
10003375
10003375
Fig. 7
- 9 -
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS - ELECTRIC FIREPLACE
18
8
15
7
4 /
5
9
6
13
14
20
2
21
23
216mm [8 1/2"] (DISTANCE BETWEEN TWO SOCKETS)
305mm [12"]
216mm [8 1/2"] (DISTANCE BETWEEN TWO SOCKETS}
#1 COMPLETE LOG SET
19
22
3
17
HE32EF
#2 COMPLETE LOG SET
- 10 -
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS LIST - ELECTRIC FIREPLACE
DESCRIPTION
HE32EF
1.
1a.
1b.
1c.
2.
Log Set Complete
Log Top Left
Log Top Right
Log Bottom
Fan/Heater Assembly w/Bracket
Motor 12VDC (Flame generator)
Switch Rocker
10003628
N/A
N/A
N/A
10001815
10001978
53606
3.
4.
5.
6.
7.
8.
On/Off Switch (Illuminated)
Thermostat - Heater Control
Potentiometer - Flame Speed Control
Circuit Board - Flame Speed Control
Knob - Flame Speed, Heater Controls
Light Filter - Ember Bed (Not Shown)
Light Diffuser Screen (Not Shown)
Screen Tinted Plastic (Not Shown)
Glass with Gasket
10001393
10001971
10001168
10001589
10001639
10001259
10001836
10001837
10001518
10001882
57914
10001536
10003618
10003377
10003093
10003095
10003104
10003105
10003127
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
Gasket Glass
Frame Window Assembly
Light Diffuser - Ember Bed (Not Shown)
Flame Generator Assembly
Facia Control Assembly
Breaker Circuit Manual Reset
Cord Power 16 / 3 HPN w/Terminals
Receptacle .093" Pin & Socket
Plug .093" Pin & Socket
Socket Light Bulb Lower Assy
- 11 -
Download from Www.Somanuals.com. All Manuals Search And Download.
FAN HEATER INSTALLATION
INSTALLATION
WARNING: UNPLUG OR TURN THE POWER TO THE APPLIANCE OFF PRIOR TO BEGIN-
NING THE INSTALLATION. IT IS NOT ACCEPTABLE TO USE THE “ON/OFF” SWITCH TO
MEET THIS REQUIREMENT.
1. Turn the power to the appliance off, or unplug it from the power supply.
2. Let fireplace cool if it has been operating.
3. Remove access panel radiance by lifting up and pulling out or open lower louvre assembly.
4. Remove two door retention screws along lower sides edge of door frame.
5. Swing lower portion of door out from the fireplace and gently lift up to disengage top of door from fire-
place (see FIG. 1).
6. Gently remove log set by removing the two screws securing the ember bed in position. One screw is
located on either side of the ember bed near the front.
7. Gently remove screen tinted plastic. Lift up to the top and swing lower portion of tinted plastic out from
bracket screen support on both sides and gently pull out slowly from fireplace.
8. Hold the fan/heater assembly and slide the assembly inside fireplace from bottom to top, turn assembly
to line up the fan/heater with bracket support in fireplace mounting with the two screw studs on bracket
support and fasten with #10-24 hex nuts provided.
9. Push connector receptacle pin and socket of the fan/heater assembly into the plug pin and socket on
fire box top.
10. Re-install screen tinted plastic, ember bed, log set, and glass door following the above procedure in
reverse.
11. Restore power to the appliance and place unit into operation check function of all of the controls
for proper operation.
Fan/Heater Assembly
- 12 -
Download from Www.Somanuals.com. All Manuals Search And Download.
TRIM OPTIONS FOR HE32EF
1) RHESS, RHESL, RHESSD, RHESLD & RHESXL TRIMS
FRAME ASSEMBLY
RHESS, RHESL, RHESSD, RHESLD and RHESXL
1. LayTrimTopFacingandTrimSideFacings,facedown
Trim Top Deflector
on to an even surface such as a table or floor. Be sure
not to scratch the painted surfaces.
2. Install the nuts and bolts (Fig. 8).
Trim Frame Top Section
Side View
10/24
SCREWS
Fig. 10
RHESSD and RHESLD (Fig. 11)
FRAME TOP
1. Install trim channels (left and right sides). Use two
screws to assemble each piece.
2. Peel off plastic protective covering from top edges of
the inner sides where the facing iner top will cover.
3. Place the trim facing inner top in place (do not fasten it
yet). Peel off the plastic protective covering from the
bottom edge.
4. Install the trim top deflector and fasten it (will hold the
inner top piece). Use two screws to assemble them.
5. Install trim channels (left and right sides). Use two
screws to assemble each piece.
LEFT
FRAME
RIGHT
FRAME
10/24
NUTS
FIG.1
AS SHOWN FROM BACK
Fig. 8
6. Slideonthetrimtopchannelandfastenitfromtheback
side.
TRIM ASSEMBLY
7. Remove ALL plastic protective covering from brass
trim.
RHESS, RHESL, and RHESXL
1. Install trim channels (left and right sides). Use two
screws to assemble each piece.
2. Slide on the trim top channel and fasten it from the back
side.
TRIM TOP CHANNEL
SCREW
TRIM FRAMING
INNER TOP
3. Install the trim top deflector and use two screws to fasten
it. (Fig. 9 & 10)
4. Remove ALL plastic protective covering from brass trim.
TRIM SIDE
CHANNEL
TRIM SIDE
CHANNEL
DEFLECTOR
TRIM TOP
TRIM TOP CHANNEL
SCREW
TRIM FRAMING
INNER SIDES
AS SHOWN FROM FRONT
TRIM SIDE
CHANNEL
TRIM SIDE
CHANNEL
DEFLECTOR
TRIM TOP
Fig. 11
A flat louvre kit OR a bay window kit
needs to be chosen to complete the
installation.
AS SHOWN FROM FRONT
Fig. 9
- 13 -
Download from Www.Somanuals.com. All Manuals Search And Download.
FRAME MOUNTING
GENERAL INFORMATION
The Decorative Front Frame should be installed last
after all other work, has been completed and thoroughly
checked and tested for operation and proper installation
requirements.
1. Fit Decorative Frame to the fireplace and fasten
(Fig. 12)
SCREWS
AS SHOWN FROM FRONT
Fig. 12
Plastic on the trim must be removed before
mounting onto the fireplace.
Glass must be tightly pressed against the
front of the frame in order to prevent
screws from damaging glass edges.
- 14 -
Download from Www.Somanuals.com. All Manuals Search And Download.
TRIM REPLACEMENT PARTS LIST
ALL repair parts will be available from your local dealer.
When ordering, always give the following information: Model and serial number, part description with finish and part
number;
KEY DESCRIPTION
RHESS(2)
RHESL(3)
RHESSD(3)
RHESLD(3)
RHESXL(4)
1
2
3
Trim Frame Top, Flat Black
Trim Frame Left, Flat Black
Trim Frame Right, Flat Black
57929
57927
57928
57932
57930
57931
57929
57927
57928
57932
57930
57931
57935
57933
57934
4
5
Trim Top Deflector(1)
Trim Top Channel(1)
17634
17634
17634
17611
17623
17609
17620
17622
55043
17634
17612
17624
17610
17619
17621
55043
17634
50586
50587
52787
6
Trim Side Channel Left(1)
Trim Facing Inner Top(1)
Trim Facing Inner Left(1)
Trim Facing Inner Right(1)
Fasteners Package (Not Shown)
50589
50590
52788
7
-
-
-
8
-
-
-
-
-
-
9
10
55043
55043
55043
(1)
(2)
(3)
(4)
Specify Finish (Antique or Polished Brass)
SS and SSD trim dimensions are for openings smaller than 261/2"H x 38" W (673mm x 965mm)
SL and SLD trim dimensions are for openings smaller than 29"H x 41" W (736mm x 1040mm)
SXL trim dimensions are for openings smaller than 32"H x 43" W (813mm x 1092mm)
5
1
4
6
2
3
6
7
9
8
- 15 -
Download from Www.Somanuals.com. All Manuals Search And Download.
2) RHEBSL & RHEBXL TRIMS
RHEBXL
TRIM ASSEMBLY
To install the kit you do not have to remove any piece
of brass, you just add the external pieces.
RHEBSL
1. Install trim channels (left and right sides). Use two
screws to assemble each piece.
2. Slideonthetrimtopchannelandfastenitfromtheback
side.
3. Install the trim top deflector and use two screws to
fasten it. (Fig. 13)
4. Remove ALL plastic protective covering from brass
trim.
Remove the frame trim from the unit if it is already
installed.
1. Installtrimchannels(leftandrightsides)byremoving
the two screws that hold the side brass trim and put
them back to hold both parts.
2. Slide on the trim top channel and fasten it from the
back side.
3. Remove the two screws that hold the top brass trim.
4. Install the two brackets to the studs in the bottom of
the top channel. Use the nuts supplied with the kit.
5. Reinstall the two screws to hold the top trim channel.
Trim Top Deflector
Trim Frame Top Section
Side View
Fig. 13
TRIM REPLACEMENT PARTS LIST
ALL repair parts will be available from your local dealer.
When ordering, always give the following information: Model and serial number, part description with finish and part
number;
KEY DESCRIPTION
RHEBSLP
RHEBSLA
RHESXLP(1)
RHESXLA(1)
1
2
3
4
5
6
7
Trim Frame Flat Black
57926
17634-PB
57864
57862
-
57926
17634-AB
57844
57843
-
-
-
Trim Top Deflector
-
-
Trim Top Channel
-
-
Trim Side Channel
-
-
Trim Outer Top Channel
Trim Outer Side Channel
Fasteners Package (Not Shown)
57861
57863
57633
57845
57846
57633
-
-
54618
54618
5
3
(1)
(2)
(4)
RHEBXLP or RHEBXLA to be used with RHEBSSLP or
RHEBSLA trims.
SL trim dimensions are for openings smaller than
271/2"H x 401/2" W (700mm x 1030mm)
XL trim dimensions are for openings smaller than
30"H x 455/8" W (765mm x 1160mm)
1
2
4
6
4
6
- 16 -
Download from Www.Somanuals.com. All Manuals Search And Download.
3) RHEFA and RHEFP TRIMS
TRIM ASSEMBLY
3. Install bottom decorative plate by simply sliding it
under the unit floor. No fastening is required for
this installation (See Fig. 16). Be sure to remove
protective cover.
1. Remove the front glass (see "Glass Frame Re-
moval" section).
2. Install support window trim channel, top and bottom
brass trim by using the shortest black screw. (Fig.
14 & 15).
4. Install the bottom louvre assembly by fastening
the hinges with four screws to the pre-punched
holes in the cabinet.
5. Re-install the front glass.
6. Install the top louvre by using the hooks to hang it
in place.
screws
TRIM-TOP
GLASS FRAME
TRIM-BOTTOM
Fig. 14
BOTTOM
DECORATIVE PLATE
Fig. 16
Louvre
Note:
Position brass trim top as
shown (small end up)
to prevent heat discolouration
Glass
Frame
Fig. 15
TRIM REPLACEMENT PARTS LIST
ALL repair parts will be available from your local dealer.
When ordering, always give the following information: Model and serial number, part description with finish and part
number;
1
2
3
KEY DESCRIPTION
RHEFA
RHEFP
1
2
3
4
5
6
7
Trim Window Top/Bottom
52624-AB
17597-AB
57905
52624-PB
17597-PB
57905
Plate Decorative Bottom
Top Louvre Assembly
Bottom Louvre Assembly
Support Window Trim Channel
Hinge
57906
57906
4
57909
57909
52356
52356
5
Fasteners Package (Not Shown)
57916
57916
6
- 17 -
Download from Www.Somanuals.com. All Manuals Search And Download.
4) HEBTKP, HESBTKP, HECBTK, HECBTKMB & HEBTA TRIMS
HECBTK
HECBKMB
HESBTKP
HEBTKP
-
-
-
-
Cast bay window and grills in classic black trim kit
Cast bay window and grills in midnight black porcelain enamel trim kit
Steel bay window with polished brass and cast grills in classic black trim kit
Steel bay window and bay louvres with polished brass trim kit
Install the bay window after all other installation work has been completed, thoroughly checked, and tested for operation, leaks
and proper installation requirements.
DO NOT REMOVE EXISTING GLASS WITH FRAME
HECBTK &
HECBTKMB
HESBTKP
HEBTKP
Fig. 17
Fig. 18
Fig. 19
HECBTKP, HECBTKMB and HESBTKP Trim Assembly
1) Install the hanging brackets, as per Fig. 20.
2) Install the two ceramic pieces inside the bay window, as per fig. 19.
3) Install the bay window by hanging it onto the lower tabs of the hanging brackets, as per Fig. 21.
4) Install the upper grill by engaging the obround holes with the upper tabs of the hanging brackets, as per Fig. 22
5) Install brass trim to the steel frame as per Fig. 23 (Only for HESBTKP trim)
- 18 -
Download from Www.Somanuals.com. All Manuals Search And Download.
HEBTKP Trim Assembly
1) Install the hanging brackets, as per Fig. 20
2) Install bracket on each side of the cabinet as per Fig. 24.
3) Install the two ceramic pieces inside the bay window, as per Fig. 19.
4) Install the bay window by hanging it onto the lower tabs of the hanging brackets, as per Fig. 21.
5) Install top louvre by engaging the obround holes with the upper tabs of the hanging brackets, as per Fig. 22.
6) Install brass trim to the steel frame as per Fig. 23.
Fig. 21 Hang the Window Grille or the Steel Frame
Fig. 20. Hanging Bracket alignment.
onto the lower tabs of the Hanging Brackets.
Fig. 22. Engage the slots in the Upper Grille Top
Louvre with the upper tabs of the Hanging
Brackets.
Fig. 23. Attach magnets and brass trim to the steel
frame.
Fig. 24. Bracket for HEBTKP.
- 19 -
Download from Www.Somanuals.com. All Manuals Search And Download.
TRIM REPLACEMENT PARTS LIST
ALL repair parts will be available from your local dealer.
When ordering, always give the following information: Model and serial number, part description with finish and part
number;
HECBTK & HECBTKMB
HESBTKP
HEBTKP
1
3
3
11
8
4
10
9
9
10
6
8
9
10
6
8
5
5
5
7
2
7
12
13
KEY DESCRIPTION
HECBTK
HECBTKMB
HESBTKP
HEBTKP
HEBTA
1
2
Trim Window Top/Bottom (1)
Plate Decorative Bottom
Top Louvre (Grill) Assembly
-
-
55188-PB
-
55188-PB
52828-PB
57945
55188-AB
-
-
52828-AB
3
1301199
-
1341199
-
1301199
-
-
-
-
-
-
-
-
-
-
-
-
-
4
Bottom Louvre (Grill) Assembly
Control Door
57947
5
1301200
1301219
1301218
1301198
1601971
1601957
1601939
10002026
-
1341200
1341219
1341218
1341198
1601971
1601957
1601939
10002026
-
1301200
1301219
1301218
1409127
1601971
1601957
1601939
10002026
-
57946
6
Bottom Louvre Left
-
7
Bottom Louvre Right
Bay Window Frame
-
8
1409127
1601971
1601957
1601939
10002026
57877
9
Glass Side
10
11
12
13
14
Glass Front
Ceramic Refractory Bay (Set)
Bracket Hanging Bay Window
Bracket Mounting Bay Window
Hardware Pkg. (Not Shown)
10000108
10000108
10000108
10000530
(1)
With magnets.
- 20 -
Download from Www.Somanuals.com. All Manuals Search And Download.
5) CAST TRIM OPTIONS
CAST SURROUND AND FLAT FACE
HECBL
Cast Surround Black
Cast Surround Blue
HECBLUE
HECCG
HECGR
Cast Surround Charcoal Grey
Cast Surround Green
CSSP
CSLP
Polished Brass Small Trim for Cast Surround
Polished Brass Large Trim for Cast Surround
(to be used with CSSP)
ACCESSORIES OPTIONS
DESCRIPTION
• Remote Control
• Optional Heater
• Cabinet / Mantel
• Ceramic Refractory Kit
• Bay Window
- 21 -
Download from Www.Somanuals.com. All Manuals Search And Download.
|