MFH-I&S-02
INSTALLATION & SERVICE MANUAL
MANUFACTURED HOME (MOBILE HOME)
GAS WATER HEATER
This water heater must be installed in accordance with local codes. In the
absence of local codes, it must be installed in compliance with The Federal
Manufactured Home Construction and Safety Stand Title 24 CRF, part 3280 or
CAN/CSA Z240 MH series, mobile home. In the absence of such standard, The
Standard for mobile Homes (ANSI/NFPA No. 601B-1977).
WARNING
If the information in these instructions is not followed exactly,
a fire or explosion may result causing property damage, personal
injury or death.
This water heater is of the closed combustion type (direct venting) where all the
combustion air is supplied from the outdoors through the air intake and all
combusted gas products are vented directly to the outside by means of the
roof jack. No draft diverter (vent hood) is required for this water heater.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable, combustible, or
corrosive vapors and liquids in the vicinity of this or any other
appliance.
Underwriters Laboratories, Inc. has tested a representative sample of this
water heater design for its safety of operation. The ULA listing of this water
heater includes the field installation of the following components: roof jack, leg
enclosure (optional), air intake tube (optional), and heater tie down materials.
These components for field installation may have been shipped with this heater
and must be installed according to the instructions (see page 8). No other
components are approved for use with this water heater.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
telephone in your building.
• Immediately call your gas supplier from a neighbor’s
telephone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
This water heater has been designed and certified for the purpose of heating
potable water. The installation and use of this water heater for any purpose
other than the heating of potable water may cause damage to the water
heater, create a hazardous condition, and nullify the warranty.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
For your family’s comfort, safety and convenience, we recommend
this water heater be installed and serviced by a plumbing
professional.
CAUTION
Incorrect operation of this appliance may create a hazard to
life and property and will nullify the warranty.
TABLE OF CONTENTS
GENERAL INFORMATION .......................................................... 1 Do not use this appliance if any part has been submerged in water. You should
INSTALLATION ..................................................................... 2 contact the plumbing professional who installed the water heater to inspect the
Locating The Water Heater ...............................................2 appliance and to replace any part of the control system including the combination
Minimum Clearances......................................................... 2 gas control which has been submerged in water.
Venting........................................................................... 3
Combustion Air Supply ..................................................... 3
Water Connections .......................................................... 4
Do not store or use gasoline or other flammable, combustible, or
DANGER
Gas Connections .............................................................. 5
Gas Conversion Instructions ............................................. 5
GENERAL OPERATION .............................................................. 6
Lighting and Shutdown Instructions.................................. 6
Thermostat Adjustment .................................................... 7
Burner Flame Check .......................................................... 7
MAINTENANCE ........................................................................ 7
corrosive vapors and liquids in the vicinity of this or any other
appliance.
IMPORTANT
Before proceeding, please inspect the water heater and components for
possible damage. DO NOT install any damaged components. If damage is evident
then please contact the supplier where the water heater was
purchased or the manufacturer listed on the rating plate for replacement parts.
TYPICAL INSTALLATION INSTRUCTIONS ..................................... 8
GENERAL INFORMATION
This water heater has been manufactured for operation at altitudes from sea
level to 2000 feet (610m) (unless otherwise specified on the water heater
rating plate). For use of this appliance at an elevation greater than 2000 feet
(610m), contact the dealer or manufacturer listed on the rating plate for
information on any necessary modification. Uncorrected operation of this
appliance may create a hazard to life and property.
This gas-fired water heater is design certified by underwriter’s laboratories in
accordance with the HUD Manufacturer Home Construction and Safety Standard,
Title 24, part 3280.
The warranty for this water heater is in effect only when the water heater is
installed, adjusted, and operated in accordance with these Installation and
Operating Instructions. The manufacturer will not be liable for any damage
resulting from alteration and/or failure to comply with these instructions.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
MFH-I&S-02
of combustion products resulting in air contamination that may be hazardous to
life. Such a condition often will result in a yellow, luminous burner flame,
causing carboning or sooting of the combustion chamber, burners and flue
tubes with possible damage to the heater.
Figure 1
Air Intake Installation - An optional 3" (7.6cm) diameter telescoping air
intake and leg enclosure are required to supply fresh air to the water heater for
combustion for 30 gallon (113.5L) water heaters and for 40 gallon (151.4L)
water heaters. Note: When a mobile home is tightly skirted, an air
inlet opening in the skirting must be provided. The opening shall
have a minimum free area of at least 9 in2 (22.9cm2). If the opening
is screened or covered with a louver, the total free area must be at
least 9 in2 (22.9cm2). The following steps must be followed for proper
installation of these air supply components: (Refer to Figure 4.)
1. After selecting the proper location for the water heater, cut a 4" 10.2cm)
diameter hole through the floor and all other layers of flooring and
sheathing directly beneath the center of the water heater.
Minimum Clearances From
Combustible Materials
A
0” (0cm) Left, 2” (5.08cm) Right
(113.6 Liters only)
0” (0cm)
4” (10.16cm)
78” (1.98m) min
----
B
C
D
VENT
VENTING
WARNING
The vent system must be installed properly. Failure to properly
install the vent system could result in property damage, personal
injury, or death.
2. Insert the air intake into the 4" (10.2cm) diameter hole and fasten to
the floor with the screws provided.
Make certain the flue baffle is in place and centered in flue tube. Place the
draft diverter over the flue opening at the top of the water heater by inserting
the tips of the draft diverter legs into the four (4) holes provided in the water
heater top. Cut a 7 1/4 inch (18.5cm) diameter hole in the ceiling and roof
directly above the flue of the water heater. Center the water heater beneath
the 7 1/4 inch (18.5cm) diameter holes in the roof and ceiling for proper
alignment of the draft diverter and roof jack vent. Apply non-hardening mastic
on the roof, around the previously cut hole, to form a weather seal with the
flashing of the gas vent roof jack assembly. Insert gas vent roof jack assembly
from above and fasten the flashing to the roof through the pre-punched holes
in the flashing. Note: Only the roof jacks listed in Figure 4 can be used
on this water heater. Apply additional non-hardening mastic to complete
the weather seal. Slip the 3inch (7.62cm) vent connector extension that is
shipped telescoped, into the gas vent roof jack assembly down onto the draft
diverter that is secured to the top of the water heater and fasten with the two
(2) sheet metal screws provided.
3. Adjust the air intake so the lower tube is extends below the underside
sheathing and secure with the screws provided. THE BOTTOM OF THE
AIR INTAKE MUST BE AT LEAST 12" (30.5cm) ABOVE THE
GROUND LEVEL.
4. Seal the openings around the air intake and underside sheathing to
resist the entrance of rodents.
5. Position the water heater so it is centered above the air intake. (Note:
The water heater should also be centered with the openings in
the roof and ceiling to allow for correct assembly of the roof
jack to the draft diverter.)
The water heater is to be secured in place using the supplied sheet metal
strapping and screws. Fasten the base of the water heater to the floor using the
screws provided. The perforated metal strapping must be fastened to the top
of the water heater and to the adjacent walls with the screws provided
(See Figure 4).
WATER CONNECTIONS
COMBUSTION AIR SUPPLY
NOTE:
WARNING
BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE.
After shutting off the main water supply, open a faucet to relieve the water line
pressure to prevent any water from leaking out of the pipes while making the
water connections to the water heater. After the pressure has been relieved,
close the faucet. The COLD water inlet and HOT water outlet are identified on
the top of the water heater. The fittings at the cold water inlet and hot water
outlet are dielectric waterway fittings with 3/4" NPT male thread. Make the
proper plumbing connections between the water heater and the plumbing
system to the house. Install a shut-off valve in the cold water supply line.
Liquefied petroleum gases/propane gas are heavier than air and will remain at floor
level if there is a leak. Basements, crawl spaces, closets and areas below ground level
will serve as pockets for accumulation of leaking gas. Before lighting, smell all around
the appliance area for gas. Be sure to smell next to the floor.
WHAT TO DO IF YOU SMELL GAS
•
•
Do not try to light any appliance.
Do not touch any electrical switch; do not use any telephone
in your building.
Immediately call your gas supplier from a neighbor’s
telephone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
•
•
CAUTION
If sweat fittings are to be use, DO NOT apply heat to the nipples on top of the
water heater. Sweat the tubing to the adapter before fitting the adapter to
the water connections. It is imperative that heat is not applied to the nipples
containing a plastic liner.
DO NOT OPERATE APPLIANCE UNTIL LEAKAGE IS CORRECTED!
IMPORTANT
The flow of combustion and ventilating air must not be obstructed.
WARNING
FAILURE TO INSTALL AND MAINTAIN A NEW, LISTED ¾” X ¾”
TEMPERATUARE AND PRESSURE RELIEF VALVE WILL RELEASE THE
MANUFACTURER FROM ANY CLAIM WHICH MIGHT RESULT FROM
EXCESSIVE TEMPERATURE AND PRESSURES.
All combustion air must be supplied from outdoors by one of the following
installation methods and as illustrated in (Figure 4). The flow of combustion
and ventilating air must not be obstructed. Adequate air must be supplied for
combustion and ventilation. An insufficient supply of air will cause recirculation
3
Download from Www.Somanuals.com. All Manuals Search And Download.
MFH-I&S-02
If this water heater is installed in a closed water supply system, such as the one
having a back-flow preventer in the cold water supply, provisions shall be made
to control thermal expansion. DO NOT operate this water heater in a closed
system without provisions for controlling thermal expansion. Your water supplier
or local plumbing inspector should be contacted on how to control this situation.
WARNING
NOTE: Some models may already be equipped or supplied with a
combination temperature and pressure relief valve. Verify that the
combination temperature and pressure relief valve complies with local
codes. If the combination temperature and pressure relief valve does
not comply with local codes, replace it with one that does. Follow the
installation instructions above on this page.
After installation of the water lines, open the main water supply valve and fill
the water heater. While the water heater is filling, open several hot water
faucets to allow air to escape from the water system. When a steady stream
of water flows through the faucets, close them and check all water connections
for possible leaks. NEVER OPERATE THE WATER HEATER WITHOUT FIRST
BEING CERTAIN IT IS FILLED WITH WATER.
Install a discharge line so that water discharged from the combination
temperature and pressure relief valve will exit within six (6) inches
(15.2 cm) above, or any distance below the structural floor and cannot
contact any live electrical part. The discharge line is to be installed to
allow for complete drainage of both the combination temperature and
pressure relief valve and the discharge line. The discharge opening
must not be subjected to blockage or freezing. DO NOT thread, plug
or cap the discharge line. It is recommended that a minimum clearance
of four (4) inches (10.2 cm) be provided on the side of the water
heater for servicing and maintenance of the combination temperature
and pressure relief valve.
WARNING
Hydrogen gas can be produced in an operating water heater that
has not had water drawn from the tank for a long period of time
(generally two weeks or more). Hydrogen gas is extremely flammable.
To prevent the possibility of injury under these conditions, we
recommend the hot water faucet to be open for several minutes at the
kitchen sink before you use any electrical appliance which is connected
to the hot water system. If hydrogen is present, there will be an
unsual sound such as air escaping through the pipes as hot water
begins to flow. Do not smoke or have open flame near the faucet at
Do not place a valve between the combination temperature and pressure
relief valve and the tank.
the time it is open.
This water heater can deliver scalding temperature water at any faucet in the
system. Be careful whenever using hot water to avoid scalding injury. Certain
appliances such as dishwashers and automatic clothes washers may require
increased temperature water. By setting the thermostat on this water heater to
obtain the increased temperature water required by these appliances, you may
create the potential for scald injury. To protect against injury, you should install
an anti-scald tempering valve in the water system. This valve will reduce point
of discharge temperature by mixing cold and hot water in branch supply lines.
Such valves are available from the local plumbing supplier. Please consult with
a plumbing professional.
WARNING
For protection against excessive temperatures and pressure, install
temperature and pressure protective equipment required by local codes,
but not less than a combination temperature and pressure relief valve
certified by a nationally recognized testing laboratory that maintains
periodic inspection of production of listed equipment or materials as
meeting the requirements of the Standard for Relief Valves and Automatic
Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 or the
Standard CAN1-4.4. Temperature and Pressure and the Standard CAN1-
4.4, Temperature, Pressure, Temperature and Pressure Relief Valves
and Vacuum Relief Valves. The combination temperature and pressure
relief valve shall be marked with a maximum set pressure not to
exceed the maximum working pressure of the water heater. The
combination temperature and pressure relief valve shall also have an
hourly rated temperature steam BTU discharge capacity not less than
the hourly rating of the water heater.
GAS CONNECTIONS
The gas supply lines must meet all requirements of the National Fuel Gas Code
ANSI Z223.1-(Latest Edition) and/or in Canada CAN/CGA B149 Installation
Codes - (Latest Editions).
The minimum permissible gas supply pressure for the purpose of input
adjustment is 1.0" water column (.25kPa) above the operating manifold pressure.
See the rating plate and combination gas control for the manifold pressure and
gas type. The maximum permissible gas supply pressure is 14.0" water column
(3.5kPa) for natural gas and liquefied petroleum gases/propane gas.
Install the combination temperature and pressure relief valve into the
opening provided and marked for this purpose on the water heater.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
MFH-I&S-02
1. Connect this water heater only to the type of gas (Natural or Propane gas)
as shown on the rating plate. Use clean 1/2"black iron pipe. (Dirt and scale
from the pipe can enter the combination control and cause it to malfunction).
The inlet gas line must have a minimum length of 3" (7.6 cm) drip leg
(sediment trap) installed as close to the water heater’s combination gas
control as possible. A ground joint union must be installed in the gas supply
line feeding the water heater to permit servicing of the water heater.
Compounds used on the threaded joints of the gas piping must be resistant
to the action of liquefied petroleum gases/propane gas.
2. This water heater and its gas connection must be leak tested before placing
the water heater in operation. Check for gas leaks with a soap and water
solution and a brush or a commercial leak detector fluid. NEVER USE A
MATCH OR OPEN FLAME FOR TESTING!
3. Change the pilot regulator by removing thermostat dial and pilot regulator
cap. Depress and rotate knob clockwise
screwdriver. Replace cap.
to the L.P. setting using a
4. Remove the outer door. Remove, or slide open, the inner door.
5. Disconnect thermocouple, Gas supply tube and pilot tube from the gas
valve and remove the burner assembly from the water heater.
6. Remove main burner orifice and pilot assembly and replace with “RED”
color coded L.P. orifice and pilot assembly provided in the cloth bag
attached to the water heater.
CAUTION
The water heater and individual shut-off valve must be disconnected from the
gas supply piping system during any pressure testing of the system at test pressures
in excess of ½ psi (3.5kPa). The water heater must be isolated from the gas supply
piping system by closing its manual shut-off valve during any pressure testing of
the gas supply system at test pressures equal to or less than ½ psi (3.5kPa). The
supply line must be capped when not connected to the water heater.
This water heater has a gas control which will operate on either natural or
liquefied petroleum (LP) gas. Normally the control is set to operate on natural
gas, but can be converted for liquefied petroleum (LP) gas by following these
instructions for gas conversion.
CAUTION
All gas conversions must be performed by qualified service personnel only.
7. Replace the burner assembly and reconnect all fittings.
8. Close and/or replace inner and outer doors.
9. To light pilot, follow the lighting instructions provided on the water heater
and in this installation and operation instruction manual.
GAS CONVERSION INSTRUCTIONS
To convert from natural gas to LP gas
1. Depress and rotate gas main burner regulator knob clockwise
the “OFF” position.
2. Change main burner gas regulator by removing cap from gas regulator.
to To convert from LP to natural gas
1. Follow the instructions above except remove the “RED” main burner orifice
and pilot assembly. Replace with the ones originally provided with the
Depress and rotate knob counterclockwise
using a screwdriver. Replace cap.
to the L.P. setting
water heater.
2. Change the main gas regulator to “NAT” as noted in step 2 of the above
instructions.
3. Change the pilot regulator to “NAT” as noted in step 3 of the above
instructions.
GENERAL OPERATION
WARNING
Water heaters are heat producing appliances. To avoid damage or injury there
shall be no materials stored against the water heater or vent-air intake system,
and proper care shall be taken to avoid unnecessary contact (especially by
children) with the water heater and vent-air intake system. UNDER NO
CIRCUMSTANCES SHALL FLAMMABLE MATERIALS, SUCH AS GASOLINE
OR PAINT THINNER BE USED OR STORED IN THE VICINITY OF THIS
WATER HEATER, VENT-AIR INTAKE SYSTEM OR IN ANY LOCATION
FROM WHICH FUMES COULD REACH THE WATER HEATER OR
VENT-AIR INTAKE SYSTEM.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
MFH-I&S-02
TO FILL THE WATER HEATER
1. Close the water heater drain valve by turning the knob clockwise.
2. Open the cold water supply shut-off valve.
3. Open several hot water faucets to allow air to escape from the system.
4. When a steady stream of water flows from the faucets, the water
heater is filled. Close the faucets and check for water leaks at the water
heater drain valve, combination temperature and pressure relief valve
and the hot and cold water connection.
5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B”: in the safety information above on this
table. If you don’t smell gas, go to the next step.
6. Remove outer door. Remove inner door or slide it open.
7. Find pilot. Follow aluminum tube from the “right underside” of the gas control.
The pilot is adjacent to the burner.
TO DRAIN THE WATER HEATER
Should it become necessary to completely drain the water heater, make
sure you follow the steps below:
1. Rotate the thermostat dial clockwise to the “PILOT LIGHTING” position.
2. Rotate and partially depress gas control knob clockwise to the “OFF”
position.
8. Turn the gas control knob to the “PILOT” position.
9 a. FOR EXHIBIT A GAS CONTROLS -
3. Shut off the gas supply to the water heater.
4. Close the cold water supply shut-off valve.
5. Open the drain valve on the water heater by turning the knob
counter-clockwise. The drain valve has threads on the end that will
allow the connection of a standard hose coupling.
6. Open a hot water faucet to allow air to enter the system.
Depress and hold down red pilot set button. Immediately light the pilot with a
match. Continue to hold down the red button for about one (1) minute after the
pilot is lit. Release button and it should pop back up. Pilot should remain lit. If it
goes out, repeat steps 5 through 9.
9b. FOR EXHBIT B GAS CONTROLS -
Depress and hold down gas control knob. Immediately light the pilot with a
match. Continue to hold down the knob for about (1) minute after the pilot is
lit. Release the knob and it should pop back up. Pilot should remain lit. If it goes
out, repeat steps 5 through 9.
To refill the water heater, refer to “To Fill the Water Heater.”
FOR YOUR SAFETY READ BEFORE LIGHTING
FOR EXHBIT A & B GAS CONTROLS -
* If button or knob does not pop up where released, stop and immediately call
your technician or gas supplier.
* If the pilot will not stay lit after several tries, turn the gas control knob to
“OFF” and call your technician or gas supplier.
WARNING
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
10. Replace inner door or slide it closed. Replace outer door.
11. Turn gas control knob counterclockwise to on position.
12. Set thermostat to desired setting.
A. This appliance has a pilot which must be lighted by hand. When lighting the
pilot, follow these instructions exactly.
13. If applicable, turn on all electric power to the appliance.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle on the
floor.
TO TURN OFF GAS TO APPLIANCE
1. Turn off all electric power to the appliance if service is to be performed.
2. Set the thermostat to the lowest setting.
3. Rotate and if applicable, partially depress gas control knob clockwise to “OFF”
position.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any telephone in your
building.
WARNING: FOR YOUR SAFETY
• Immediately call your gas supplier from a neighbor’s telephone. Do not store or use other flammable, combustible, or corrosive vapors or liquids in the
Follow the gas supplier’s instructions.
vicinity of this or any other appliance.
• If you cannot reach your gas supplier, call the fire department.
WARNING: HOT WATER CAN PRODUCE 3RD DEGREE BURNS
C.. Use only your hand to push in or turn the gas control knob. Never use tools. If In 6 seconds at 140°F (60°C) - In 30 seconds at 130°F (24°C)
the knob will not push in or turn by hand, don’t try to repair it, call a qualified
service technician. Force or attempted repair may result in a fire or explosion.
Vapors from flammable liquids will explode and catch fire causing death or severe
D. Do not use this appliance if any part has been under water, immediately call a burns.
qualified service technician to inspect the appliance and to replace any part of Read and follow water heater warnings and instructions. If installation and operation
the control system and any gas control which has been under water.
instructions are missing, contact the retailer or manufacturer.
LIGHTING INSTRUCTIONS
1. Stop! Read the safety information above on this label.
2. If applicable, turn off all electric power to appliance.
This appliance must be installed in accordance with local codes or, in the absence of local
codes, the National Fuel Gas Code, ANSI 7223.1. Or the CAN/CGA-B149 installation
codes. For installation in a manufactured home (mobile home).
3. Rotate the thermostat dial counter-clockwise to the lowest possible position.
4. Rotate gas control knob clockwise to the “OFF” position.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
MFH-I&S-02
BURNER FLAME CHECK
CAUTION: Operation of this water heater in air contaminated by
perchloroethylene, any chlorinated hydrocarbon or strong oxidizing agents, will result
Steel Burner: These models are equipped with self adjusting air mixture and
do not have an adjustable air shutter (See Figure 3). At periodic intervals, a
visual check of the main burner and pilot flames should be made to determine
if they are burning properly. The main burner flame should light smoothly from
the pilot.
in serious damage to brass orifices, internal steel parts and void the warranty.
IMPORTANT – BURNER MUST BE LEVEL. Models containing a cast iron burner
are equipped with an adjustable air shutter. The air shutter on the front of the main
burner must be adjusted when the water heater is installed. See installation instructions
for proper air shutter adjustment procedures.
STATE OF CALIFORNIA NOTICE
WARNING: This water heater must be braced, anchored or strapped to
avoid falling or moving during an earthquake. See instructions for correct installation
procedures.
WARNING: If not installed, operated and maintained in accordance with
the manufacturer’s instructions this product could expose you to substances in the fuel
or form combustion which can cause death or serious illness including, cancer, birth
defects or other reproductive harm.
Figure 3
MAINTENANCE
SUITABLE FOR WATER (PORTABLE) HEATING AND SPACE HEATING
Toxic chemicals, such as used for boiler treatment, shall not be introduced into potable
water heater used for space heating. This water heater may never be connected to any
existing heating system or component(s) previously used with a nonpotable water
heater appliance.
WARNING
Water heaters are heat producing appliances. To avoid damage or injury there
shall be no materials stored against the water heater or vent-air intake system
and proper care shall be taken to avoid unnecessary contact (especially by
children) with the water heater and vent-air intake system. UNDER NO
CIRCUMSTANCES SHALL FLAMMABLE MATERIALS, SUCH AS
GASOLINE OR PAINT THINNER BE USED OR STORED IN THE
VICINITY OF THIS WATER HEATER, VENT-AIR INTAKE SYSTEM OR IN
ANY LOCATION FROM WHICH FUMES COULD REACH THE WATER
HEATER OR VENT-AIR INTAKE SYSTEM.
THERMOSTAT ADJUSTMENT
The thermostat dial is adjusted to its lowest temperature position when shipped
from the factory. When adjusting the thermostat it should be remembered
that lower temperature settings are more energy efficient. To adjust the
thermostat, turn the dial clockwise until the minimum acceptable temperature
is set. It is suggested that the starting point setting not exceed the “HOT” mark
[approximately 120°F (49° C)] on the thermostat, as indicated in Figure 2.
IMPORTANT
The water heater should be inspected at a minimum annually by a
qualified service technician for damaged components and/or joints
not sealed. DO NOT operate this water heater if any part is found
damaged or if any joint is found not sealed.
Figure 2
The following maintenance should be performed by a qualified service technician
at the minimum periodic intervals suggested below. In some installations, the
maintenance interval may be more frequent depending on the amount of use
and the operating conditions of the water heater. Regular inspection and
maintenance of the water heater and vent-air intake system will help to ensure
safe and reliable operation.
1. Annually check the operation of the thermostat.
2. The flow of combustion and ventilation air MUST NOT be restricted. Clear
DANGER
Hotter water increases the risk of scald injury. Scalding may occur within
the combustion air openings of any dirt, dust, or other resctrictions.
five (5) seconds at a temperature setting of 135°F (57°C). To protect
against hot water injury, install an anti-scald tempering valve in the water
system. This valve will reduce point of discharge temperature by mixing
cold and hot water in branch water lines. A licensed plumbing professional
or local plumbing authority should be consulted.
Note: This water heater is equipped with an energy cut out device to
prevent overheating. Should overheating occur or the gas supply fail to
shut off, turn off the manual gas control valve to the appliance and call
qualified service technician.
Note: Whenever the water heater is filled with cold water, condensate will form on
the cool tank surface and drops of water will fall on the hot burner and combustion
chamber surfaces producing a “sizzling” noise. Condensation is normal and does
not indicate a leak. It will disappear when the tank becomes heated.
WARNING! The ventilation air system may be HOT.
3. At all times keep the water heater area clear and free from combustible
materials, gasoline and other flammable vapors and liquids.
4. Bi-annually conduct a visual check of the main and pilot burner flames to
determine that they are burning properly. See Burner Flame Check section
on page 7.
5. Annually remove the inner door and main burner assembly to clean orifices
and related parts of any dirt or other foreign material. Inspect the burner
ports for obstructions or debris and clean with a wire brush as needed. Wire
brush and/or vacuum clean the combustion chamber as needed to remove
scale deposits and debris. Note: It is imperative for proper operation of
the water heater that the inner door be replaced in the original location.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
MFH-I&S-02
9. A combination sacrificial anode rod/hot water outlet nipple has been
installed to extend tank life. The anode rod should be inspected periodically
(every 2 years) and replaced when necessary to prolong tank life. Water
conditions in your area will influence the time interval for inspection and
replacement of the anode rod. Contact the plumbing professional who
installed the water heater or the manufacturer listed on the rating plate for
anode replacement information. The use of a water softener may increase
the speed of anode consumption. More frequent inspection of the anode
is needed when using softened (or phosphate treated) water.
WARNING
When lifting lever of the combination temperature and pressure
relief valve, hot water will be released under pressure. Be
careful that any released water does not result in bodily injury
or property damage.
6. At least once a year, check the combination temperature and pressure
relief valve to insure that the valve has not become encrusted with lime.
Lift the lever at the lever at the top of the valve several times until the
valve seats properly without leaking and operates freely.
CAUTION
7. Monthly drain off a gallon of water to remove silt and sediment.
FOR YOUR SAFETY, DO NOT ATTEMPT REPAIR OF COMBINATION GAS CONTROL,
WARNING! THIS WATER MAY BE HOT.
BURNERS OR GAS PIPING. REFER REPAIRS TO A QUALIFIED SERVICE TECHNICIAN.
8. If the combination temperature and pressure relief valve on the appliance
discharges periodically, this may be due to thermal expansion in a closed
water supply system. Contact the water supplier or local plumbing inspector
on how to correct this situation. Do not plug the combination temperature
and pressure relief valve outlet.
Contact your supplier or plumbing professional for replacement parts or contact
the company at the address given on the rating plate of the water heater.
Provide the part name, model and serial numbers of the water heater when
ordering parts.
TYPICAL INSTALLATION - VENTING
Figure 4
4-08/Printed in USA
8
Download from Www.Somanuals.com. All Manuals Search And Download.
|