Listen Technologies Power Supply PS 6000 User Manual

DCS 6000  
User Manual  
Digital Conference System  
PS 6000 Power Supply  
Danish Interpretation Systems  
DIS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
List of Contents  
System design.....................................................7  
List of Contents..................................................... 3  
Important .............................................................. 4  
Use of PS 6000 ................................................8  
System Setup..........................................................9  
General guidelines .............................................9  
Compliancy........................................................ 4  
Safety.................................................................. 4  
Installation precautions.................................... 4  
Cleaning & Repacking...................................... 4  
Warranty ........................................................... 4  
Max. number of units to be connected...........10  
CM/DM 60x0P Chairman/Delegate Units.....10  
CM/DM 60x0P Chairman/Delegate Units & JB  
6002 Junction Box .........................................10  
Description of the DCS 6000 system ................... 5  
Features.............................................................. 5  
CM/DM 6060F/6510F Chairman/Delegate  
Units...............................................................11  
CM/DM 6560F Chairman/Delegate Units.....11  
System components........................................... 6  
MU 6040 C/D without connected loudspeaker  
.......................................................................12  
Central equipment etc...................................... 6  
Interpreter equipment...................................... 6  
Voting equipment............................................ 6  
Conference equipment and channel selectors . 6  
IS 6132P Interpreter Units .............................12  
IS 6132P w/JB 6004 and LS 6032.................13  
CS 6032F Channel Selector w/back light on .13  
Operating instructions ......................................... 7  
Appendix..............................................................14  
PS 6000 Power Supply...................................... 7  
Technical appendix..........................................14  
General description ......................................... 7  
Cabling...........................................................14  
Features ........................................................... 7  
Connectors....................................................... 7  
Accessories (not supplied).............................14  
Technical specifications.................................14  
Copyright © 2007 DIS  
PS6000 REV B.DOC  
21-05-2007  
No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the  
publisher.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Important  
The equipment must be connected to earth  
Compliancy  
Installation precautions  
The equipment has been tested and found to comply  
with the limits of the following standards for digital  
devices:  
Allow adequate air circulation to prevent internal  
heat built-up. Do not place the unit on a surface  
(rugs, blankets, etc.) that may block the ventilation  
holes.  
EN55103-1 (Emission)  
EN55103-2 (Immunity  
EN60065 safety  
UL6500 safety  
FCC rules part 15, class A (Emission)  
Do not install the unit in a location near heat  
sources such as radiators or air ducts, or in a place  
exposed to direct sunlight, excessive dust or  
humidity, mechanical vibration or shock.  
This device complies with part 15 of the FCC rules.  
Operation is subject to the following conditions: (1)  
This device may not cause harmful interference,  
and (2) this device must accept any interference  
received, including interference that may cause  
undesired operation.  
To avoid moisture condensations do not install the  
unit where the temperature may rise rapidly.  
When installing the unit inside a 19” rack, observe  
that the rack is properly ventilated. The maximum  
allowed temperature inside the rack is 40 °C.  
These limits are designed to provide reasonable  
protection against harmful interference when the  
equipment is operated in residential, commercial or  
light industrial environments. The equipment  
generates, uses, and can radiate radio frequency  
energy and if not installed and used in accordance  
with the user manual it may cause harmful  
interference to radio communications.  
Cleaning & Repacking  
To keep the cabinet in its original condition,  
periodically clean it with a soft cloth. Stubborn  
stains may be removed with a cloth lightly  
dampened with a mild detergent solution. Never use  
organic solvents such as thinners or abrasive  
cleaners since these will damage the cabinet.  
You are cautioned that any changes or  
modifications not expressly approved in this manual  
could void your authority to operate this equipment.  
Save the original shipping cardboard box and  
packing material; they will become handy if you  
ever have to ship the unit. For maximum protection,  
re-pack the unit as originally packed from the  
factory.  
Safety  
Check that the voltage of your local power supply is  
within the operating voltage of the unit (100-240V  
AC). If a voltage conversion is required, consult  
your DIS dealer or qualified personnel.  
Warranty  
The unit is minimum covered by 12 months  
warranty against defects in materials or work-  
manship.  
Should any liquid or solid object fall into the  
cabinet, unplug the unit and have it checked by  
qualified personnel before operating it further.  
Set the Power switch to OFF if it is not used for  
several days.  
Manual 01 18 04450  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Description of the DCS 6000 system  
Added functionality and comprehensive  
features provided by SW 6000 software  
package running on PC  
Features  
The DCS 6000 system has the following main  
features:  
RS232/RS422 connection on CU 6005/6010 for  
external operation of the system of a PC or  
control system such as AMX or Crestron  
Fully digital  
Excellent sound quality  
The SW 6000 is an optional software package,  
which expands the functionality of the DCS 6000  
system. The software runs on standard computer  
technology (Standard PC with Windows 2000 or  
XP).  
“State of the Art” fully digital integrated  
interpretation, discussion and voting system  
offering interpretation, language distribution,  
conference microphone and voting facilities  
with attendance check with Chip Card ™.  
Main features of the SW 6000 are:  
New, unique digital DATA and AUDIO bus.  
Microphone management  
Mimic panel operation  
Interpretation management  
Voting management  
39 incoming channels (8 floor channels + 31  
interpreted channels) and one Line input.  
34 distributed channels (3 x floor + 31  
interpreted channels)  
Message handling  
The Delegate and Interpreter units are powered  
and controlled by the CU 6005 Central Unit,  
which drives up to app. 50 units on 2 chains or  
by the CU 6010 Central Unit, which drives up  
to app. 200 units on 4 chains.  
Agenda handling  
Data stored on SQL data base  
Web interface available for easy links to  
external databases  
EX 6010 Extension Units or PS 6000 Power  
Supplies available if more units are required  
Multi language user interfaces  
A total of 4000 units (delegate and/or  
interpreter units) can be connected to the  
system.  
Supports different User types with different  
priorities, user interfaces and control  
possibilities  
Using screened CAT5 or CAT5e cabling (FTP  
or STP) ensuring a very cost effective  
installation and easy set-up of portable systems  
Variety of printing facilities such as speaker’s  
log, voting results, delegates list etc.  
Firmware in Delegate units, Interpreter Units,  
Central Units etc. upgradeable through serial  
PC-connection (RS232 or RS422)  
Can be operated with or without a PC.  
Manual 01 18 04450  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Conference equipment and channel  
selectors  
System components  
The CU 6005/6010 Central Unit supports all  
available units in the DCS 6000 series:  
CS 6032FV/H  
DM 6010P  
Channel Selector (flush mounted)  
Conference Unit (portable)  
DM 6060P  
Conference Unit (portable) with  
one built-in channel selector  
Central equipment etc.  
EX 6010  
PS 6000  
AO 6004  
AO 6008  
RP 6004  
JB 6002  
JB 6004  
Extension Unit  
Power Supply  
Audio Output box  
Audio Output box  
Repeater for four chains  
Junction Box with 2 outputs  
Junction Box with 4 outputs  
CM/DM 6070P Conference Unit (portable) with  
two built-in channel selectors  
CM/DM 6090P Conference Unit (portable) with  
two built-in channel selectors and  
XLR microphone connector  
CM/DM 6060F Conference Unit (flush mounted)  
with one built-in channel  
selectors  
CM/DM 6510F Conference Unit (flush mounted)  
with Chip-card and 3 voting  
buttons  
CM/DM 6560F Conference Unit (flush mounted)  
with one built-in channel  
selector, Chip-card and 3 voting  
buttons  
Interpreter equipment  
IS 6132P  
LS 6132P  
Interpreter Set  
Interpreter Loudspeaker  
Voting equipment  
MU 6040C/D  
Microphone Unit for use with  
customised front plate with  
Loudspeaker, Microphone and  
Buttons. Available in Delegate  
(D) and Chairman (C) version  
DV 6501F Voting Unit  
MU 6042D  
AM 6040  
Dual Microphone Unit for use  
with FD/FC front plate with  
Loudspeaker, Microphone and  
two delegate Buttons  
Ambient Noise Microphone  
Manual 01 18 04450  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Operating instructions  
PS 6000 Power Supply  
Delayed switching on of power to minimise the  
total ‘switch-on’ current on the Mains supply.  
General description  
The PS 6000 Power Supply provides additional  
Power for the DCS 6000 system.  
Designed in a small size easy-to-install cabinet.  
One CU 6005/6010 Central Unit is needed in each  
DCS 6000 system; however for expansion of the  
system the PS 6000 Power Supply is suitable. The  
PS 6000 consists of:  
Connectors  
The PS 6000 Power Supply features the following  
connectors:  
One Power Supply  
Power connector  
Connection for main power.  
Control electronic for detecting system power  
Loop through connectors  
Features  
RJ45 connector, 2 pieces  
The main features of the PS 6000 Power Supply  
are:  
DCS-LAN connectors used for connection to the  
CU 6005/6010 and for connection to other units  
with DCS-LAN connectors such as more PS 6000.  
Built in Power Supply for app 60 units  
(Delegates) or app. 150 Channel Selectors  
Power LED  
One connector for connection to Delegate  
Units, Interpreter Units etc.  
Those green LED light up when Power is available  
on the connector next to the LED.  
One connector for connection previous unit (i.e.  
CU 6005/6010.  
System design  
There are no settings to be done on the PS 6000  
Power Supply.  
And the PS 6000 is NOT a repeater, which means  
that the maximum cable length in a chain (which  
without repeater is 200 m) has to be calculated from  
the last unit with repeater functionality (typically a  
CU 6005/6010, EX 6010 or RP 6004) to the last  
unit connected to the PS 6000.  
However it is important to observe, that the unit is  
only adding power to one of the chains on the CU  
6005/6010 Central Unit.  
And as so, the specification, which applies the two  
chain outputs on the CU 6005 Central Unit and to  
each of the chain outputs on the CU 6010 Central  
Unit, does also apply to the output on the PS 6000.  
This includes interconnection cables between the  
units.  
Manual 01 18 04450  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Use of PS 6000  
The PS 6000 can be inserted at any point in a DCS  
6000 chain, where extra power is needed. The PS  
6000 is used, when extra power is needed typically,  
where long feeding cables are needed.  
A typical application is to place a PS 6000 in the  
first Interpreter Booth to compensate for a long  
feeding cable.  
The following schematic shows various ways in  
how to use the PS 6000 Power Supply:  
Manual 01 18 04450  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
System Setup  
General guidelines  
Connect the PS 6000 to the various DCS 6000 units  
using Cat5 or Cat5e FTP or STP screened cables.  
Please observe the following guidelines:  
between the units are short, more units can  
be connected than if the feeding cable is  
long and/or the cables are long between the  
units. Please consult the next section (Max.  
Number of units to be connected)  
Maximum cable length in one chain is 200  
without repeater. This includes  
m
interconnection cables between the units.  
The max. usable cable length depends on  
the units connected and length of feeding  
cables etc.  
If the last unit in one chain is a CS 6032  
Channel Selector, this unit has to be  
terminated with an external termination, as  
the CS 6032 does not have an internal  
termination.  
Maximum cable length in one chain when  
using repeaters is 650 m.  
It is desirable that the square of the feeding cables  
especially, but also the interconnection cables are as  
big as possible to minimize the voltage drop in the  
cables. Cat 5/Cat5E cables are delivered in various  
gauges:  
Although the output on the PS 6000 have a  
125W supply, this 125W power is not all  
usable with long cables, as there will be a  
voltage drop in the feeding cable from the  
PS 6000 to the units connected. If the  
feeding cables are short and the cables  
The following table is showing the Diameter/square  
for various AWG types  
Type  
Diameter  
Square  
AWG22  
0.64 mm  
0.57 mm  
0.53 mm  
0.42 mm  
0.32 mm2  
AWG23/1  
AWG24  
AWG26  
0.25 mm2  
0.22 mm2  
0.14 mm2  
Manual 01 18 04450  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Max. number of units to be connected  
The following tables show the maximum number of  
units, which can be connected to the two outputs  
(A1 or A2) on a CU 6005 Central Unit in total or to  
each of the four outputs (A1, A2, B1 or B2) on a  
CU 6010 Central Unit or to each output on an EX  
6010 Extension Unit or to the output of a PS 6000  
Power Supply.  
CM/DM 60x0P Chairman/Delegate Units  
Length of Feeding Cable  
Type CAT5 AWG24  
Length of inter connecting  
Cable, Type CAT5 AWG24  
Total cable length  
Max. number of CM/DM  
60x0 pr output  
10 m  
30 m  
50 m  
100 m  
150 m  
10 m  
30 m  
50 m  
100 m  
150 m  
1 m  
1 m  
1 m  
1 m  
1 m  
2 m  
2 m  
2 m  
2 m  
2 m  
51 m  
67 m  
83 m  
123 m  
165 m  
88 m  
42  
38  
34  
24  
16  
40  
35  
30  
22  
16  
98 m  
108 m  
142 m  
180 m  
CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box  
This configuration shows two CM/DM 60x0  
Delegate/Chairman Units connected to one JB 6002  
Junction Box with 3m cables between each JB  
6002. Maximum 5 m cable from JB 6002 to  
CM/DM 60x0 and max. one CM/DM 60x0 on each  
output of JB 6002.  
Length of Feeding Cable, Length of Cable between each Total cable  
Number of  
JB 6002  
Max. number of  
DM 60x0  
Type CAT5 AWG24  
JB 6002, Type CAT5 AWG24  
length  
10 m  
30 m  
50 m  
100 m  
150 m  
3 m  
3 m  
3 m  
3 m  
3 m  
61 m  
75 m  
89 m  
127 m  
168 m  
18  
16  
14  
10  
7
36  
32  
28  
20  
14  
Manual 01 18 04450  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
CM/DM 6060F/6510F Chairman/Delegate Units  
The following tables show the maximum number of  
units, which can be connected to the two outputs  
(A1 or A2) on a CU 6005 Central Unit in total or to  
each of the four outputs (A1, A2, B1 or B2) on a  
CU 6010 Central Unit or to each output on an EX  
6010 Extension Unit or to the output of a PS 6000  
Power Supply.  
Length of Feeding Cable  
Type CAT5 AWG24  
Length of inter connecting  
Cable, Type CAT5 AWG24  
Total cable length  
Max. number of  
CM/DM 60x0 pr output  
10 m  
30 m  
50 m  
100 m  
150 m  
10 m  
30 m  
50 m  
100 m  
150 m  
1 m  
1 m  
1 m  
1 m  
1 m  
2 m  
2 m  
2 m  
2 m  
2 m  
39 m  
56 m  
73 m  
115 m  
160 m  
64 m  
78 m  
94 m  
130 m  
170 m  
30  
27  
24  
16  
11  
28  
25  
23  
16  
11  
CM/DM 6560F Chairman/Delegate Units  
Length of Feeding Cable  
Type CAT5 AWG24  
Length of inter-connecting  
Cable, Type CAT5 AWG24  
Total cable length  
Max. number of CM/DM  
60x0 pr output  
10 m  
30 m  
50 m  
100 m  
150 m  
10 m  
30 m  
50 m  
100 m  
150 m  
1 m  
1 m  
1 m  
1 m  
1 m  
2 m  
2 m  
2 m  
2 m  
2 m  
35 m  
53 m  
70 m  
113 m  
159 m  
58 m  
72 m  
88 m  
126 m  
166 m  
27  
24  
21  
14  
10  
25  
22  
20  
14  
9
Manual 01 18 04450  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
MU 6040 C/D without connected loudspeaker  
This table shows the maximum number of MU  
6040 Microphone Units, which can be connected.  
The numbers are with no audio in loudspeaker (no  
loudspeaker connected to each unit). If  
loudspeakers are used, then use the figures for  
CM/DM 60x0 above.  
Length of Feeding Cable, Cable length between  
Total cable length  
Max. number of  
MU 6040  
Type CAT5 AWG24  
each MU 6040  
10 m  
30 m  
50 m  
100 m  
150 m  
100 m  
150 m  
2 m  
2 m  
2 m  
2 m  
2 m  
1 m  
1 m  
168 m  
178 m  
188 m  
80  
75  
70  
200 m (202 m)  
200 m (232 m)  
151 m  
51 (52*)  
26 (42*)  
52  
191 m  
42  
Numbers in (‘) are the number of units, which could  
have been connected CU/EX, but where the total  
number of units has been lowered due to the  
restriction of the maximum length of cable (200 m).  
IS 6132P Interpreter Units  
This table shows the maximum number of IS 6132P  
Interpreter Sets, which can be connected. The  
numbers are with no audio in loudspeaker (no  
loudspeaker connected to each unit).  
Note: The number of units is dependant of how  
many interpreter sets there are per booth (or  
language), as there only can be one set switched ON  
per language (channel).  
If loudspeakers are used, then use the figures for  
CM/DM 60x0 above.  
Length of Feeding Cable,  
Type CAT5 AWG24  
Length of inter-connecting Cables,  
Type CAT5 AWG24  
Max. number of units pr output  
All ON ½ ON 1/3 ON  
10m  
30m  
50m  
100m  
150m  
2 m  
2 m  
2 m  
2 m  
2 m  
54  
49  
44  
35  
25  
x
x
60  
x
x
x
57  
51  
40  
30  
Manual 01 18 04450  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
IS 6132P w/JB 6004 and LS 6032  
Length of Feeding Cable,  
Type CAT5 AWG24  
Length of cable  
between booths  
Number of  
booths  
Number of  
IS 6132/ booths  
Number of  
LS 6032/ booths  
10 m  
10 m  
30 m  
30 m  
50 m  
5 m  
5 m  
5 m  
5 m  
5 m  
5 m  
5 m  
5 m  
5 m  
5 m  
19  
12  
17  
10  
15  
9
11  
7
8
4
4
4
4
4
4
4
4
4
4
0
4
0
4
0
4
0
4
0
4
50 m  
100 m  
100 m  
150 m  
150 m  
5
CS 6032F Channel Selector w/back light on  
Length of Feeding Cable  
Type CAT5 AWG24  
Length of Inter-connecting Total cable length Max. number of CS 6032 pr  
cable, Type CAT5 AWG24  
output  
30 m  
50 m  
100 m  
150 m  
10 m  
30 m  
50 m  
100 m  
150 m  
1 m  
1 m  
1 m  
1 m  
2 m  
2 m  
2 m  
2 m  
2 m  
139 m  
144 m  
184 m  
200 m  
200 m  
200 m  
200 m  
200 m  
200 m  
110  
95  
85  
51 (67’)  
96  
86 (90’)  
76 (85’)  
51 (70’)  
26 (60’)  
Numbers in (‘) are the number of units, which could  
have been connected to the CU/EX, but where the  
total number of units has been lowered due to the  
restriction of the maximum length of cable (200 m).  
Manual 01 18 04450  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Appendix  
Technical appendix  
Pair 1: Pin 1 & 2  
Pair 2: Pin 3 & 6  
Pair 3: Pin 4 & 5  
Pair 4: Pin 7 & 8  
Cabling  
CAT5  
The DCS 6000 system uses CAT5, CAT5e or  
CAT6 FTP or STP cables with screened RJ45  
connectors.  
The phase of the pairs must be correct and the  
wiring spec. as stated in CAT5 (EIA 568-B) have to  
be followed.  
EIA 568-B wiring shall be used.  
It is important to use only FTP or STP  
(screened) cables and screened RJ45 connectors  
and not UTP cable, which is unscreened.  
Note: CAT6 cables can normally only be  
terminated in sockets (female) and not in cable  
plugs.  
How to wire a CAT5 (EIA 568-B) Cable:  
CAT6 can thus only be used for longer cable draws  
terminating in wall outlets or patch panels.  
Pin Function  
Connector #1 Connector #2  
1
2
3
4
5
6
7
8
In-going + ORG/WHT  
ORG/WHT  
ORG  
GRN/WHT  
BLU  
BLU/WHT  
GRN  
Accessories (not supplied)  
In-going -  
+48V  
0V  
ORG  
GRN/WHT  
BLU  
Cat 5e Connection Cables (AWG24)  
EC 6000-..5 Connection Cable 0.5 m......................10 03 12500  
EC 6000-01 Connection Cable 1 m.........................10 03 13101  
EC 6000-02 Connection Cable 2 m.........................10 03 13201  
EC 6000-05 Connection Cable 5 m.........................10 03 13501  
EC 6000-10 Connection Cable 10 m.......................10 03 14102  
EC 6000-20 Connection Cable 20 m.......................10 03 14202  
EC 6000-50 Connection Cable 50 m.......................10 03 14502  
0V  
+48V  
BLU/WHT  
GRN  
Outgoing - BRN/WHT  
Outgoing + BRN  
BRN/WHT  
BRN  
Note. If other colour codes are used then the four  
pairs are connected as follows:  
Technical specifications  
Weight..................................................................................1 kg  
Dimensions (W x H x D).................... 100 (125) x 50 x 205 mm  
Dimensions in bracket are including the fixing bracket  
Accessories supplied.................................................Main cable  
Connectors  
General  
Power consumption .................................................max. 150W  
Mains voltage: ........................................100 - 240V, 50...60Hz  
Supply voltage for units............................................ 48V/125W  
Temperature to guarantee specified performance  
DCS-LAN loop through....................................... 2 pieces RJ45  
Specifications are subject to change without notice.  
..............................5 Deg C. to 40 Deg C. (35 to 80% humidity)  
Storage temperature  
.......................... -20 Deg C. to 60 Deg C. (10 to 80% humidity)  
Manual 01 18 04450  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  

LG Electronics Car Satellite TV System 32LX570H User Manual
LG Electronics Car Satellite TV System 42PC7R 50PC5R User Manual
LG Electronics DVD Player DVX9900H User Manual
Lochinvar Boiler 400 801 User Guide
Magnavox Cassette Player AZ 1307 User Manual
Magnavox TV DVD Combo 26MD25ID 32MD25ID User Manual
Makita Cordless Drill 6913D User Manual
Maytag Clothes Dryer MED9800TK0 User Manual
MEY Equipment Lawn Mower 26TCVM User Manual
MicroNet Technology IP Phone SP5001A S User Manual