DCS 6000
User Manual
Digital Conference System
RP 6004 Repeater
Danish Interpretation Systems
DIS
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
List of Contents
RP 6004 Repeater...........................................7
List of Contents................................................. 3
Document version.......................................... 3
General description....................................... 7
Features....................................................... 7
User Controls, indications & connectors........ 7
System design .............................................. 8
Important ......................................................... 4
Compliancy................................................... 4
Installation precautions ................................. 4
Cleaning ........................................................ 4
Repacking...................................................... 4
Warranty....................................................... 4
System Setup...................................................10
General guidelines........................................10
Built into 19” Racks .....................................10
Typical schematics .......................................11
Description of the DCS 6000 system.................. 5
Features......................................................... 5
Large sized conference microphone system.. 11
Various configurations with RP 6004 Repeater
and PS 6000 Power Supply ......................... 12
System components ....................................... 6
Central equipment.........................................6
Technical appendix .........................................13
Interpreter equipment....................................6
Conference equipment and channel selectors ..6
Cabling...................................................... 13
Accessories (not supplied) .......................... 13
Operating instructions ...................................... 7
Technical specifications................................13
Document version
Printed:
Name:
17-10-2004
Version:
C
RP6004-REV-C.DOC
Copyright © 2003 Danish Interpretation Systems
No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher.
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
Important
exposed to direct sunlight, excessive dust or
humidity, mechanical vibration or shock.
Compliancy
The equipment has been tested and found to comply
with the limits of the following standards for digital
devices:
To avoid moisture condensations do not install the
unit where the temperature may rise rapidly.
·
·
·
EN55103-1 (Emission)
EN55103-2 (Immunity)
FCC rules part 15, class A (Emission)
Cleaning
To keep the cabinet in its original condition,
periodically clean it with a soft cloth. Stubborn
stains may be removed with a cloth lightly
dampened with a mild detergent solution. Never use
organic solvents such as thinners or abrasive
cleaners since these will damage the cabinet.
This device complies with part 15 of the FCC rules.
Operation is subject to the following conditions: (1)
This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
Repacking
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial or light
industrial environment. The equipment generates,
uses, and can radiate radio frequency energy and if
not installed and used in accordance with the user
manual it may cause harmful interference to radio
communications.
Save the original shipping cardboard box and
packing material; they will become handy if you
ever have to ship the unit. For maximum protection,
re-pack the unit as originally packed from the
factory.
Warranty
You are cautioned that any changes or
modifications not expressly approved in this manual
could void your authority to operate this equipment.
The individual units in the DCS 6000 system are
minimum covered by 12 months warranty against
defects in materials or workmanship.
Installation precautions
Do not install the unit in a location near heat
sources such as radiators or air ducts, or in a place
.
Manual 01 18 04466
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
Description of the DCS 6000 system
RS232/RS422 connection on CU 6010 for
external operation of the system of a PC or
control system such as AMX or Crestron
Features
The DCS 6000 system has the following main
features:
The SW 6000 is an optional software package,
which expands the functionality of the DCS 6000
system. The software runs on standard computer
technology (Standard PC with Windows 2000 or
XP).
·
·
·
Fully digital
Excellent sound quality
“State of the Art” fully digital integrated
interpretation, discussion and voting system
offering interpretation, language distribution,
conference microphone and voting facilities
with attendance check with Chip Card ™.
Main features of the SW 6000 are:
·
·
·
·
·
·
·
Microphone management
Mimic panel operation
Interpretation management
Voting management
Message handling
·
·
New, unique digital DATA and AUDIO bus.
39 incoming channels (8 floor channels + 31
interpreted channels) and one Line input.
·
·
33 distributed channels (2 x floor + 31
interpreted channels)
Agenda handling
Data stored on SQL data base for easy
export/import of data as well as easy links to
external databases
The Delegate and Interpreter units are powered
and controlled by the CU 6010 Central Unit,
which drives up to app. 200 units on 4 chains.
·
·
Multi language user interfaces
·
·
EX 6010 Extension Units or PS 6000 Power
Supplies available if more units are required
Supports different User types with different
priorities, user interfaces and control
possibilities
A total of 4000 units (delegate and/or
interpreter units) can be connected to the
system.
Variety of printing facilities such as speaker’s
log, voting results, delegates list etc.
·
·
Using screened CAT5 or CAT5e cabling (FTP
or STP) ensuring a very cost effective
installation and easy set-up of portable systems
Firmware in Delegate units, Interpreter Units,
Central Units etc. upgradeable through serial
PC-connection (RS232 or RS422)
·
·
Can be operated with or without a PC.
Added functionality and comprehensive
features provided by SW 6000 software
package running on PC
Manual 01 18 04466
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
Conference equipment and channel
selectors
System components
The CU 6010 Central Unit supports all available
units in the DCS 6000 series:
CS 6032FV/H
CM/DM 6010P Conference Unit (portable)
Channel Selector (flush mounted)
CM/DM 6020P Conference Unit (portable) with
XLR microphone connector
Central equipment
CM/DM 6070P Conference Unit (portable) with
two built-in channel selectors
CM/DM 6090P Conference Unit (portable) with
two built-in channel selectors and
CU 6010
EX 6010
PS 6000
RP 6004
AO 6008
JB 6002
JB 6004
Central Unit
Extension Power Unit
Power Supply
Repeater for four chains
Audio Output box
Junction Box with 2 outputs
Junction Box with 4 outputs
XLR microphone connector
CM/DM 6060F Conference Unit (flush mounted)
with one built-in channel
selectors
CM/DM 6510F Conference Unit (flush mounted)
with Chip-card and 3 voting
buttons
CM/DM 6560F Conference Unit (flush mounted)
with one built-in channel
selector, Chip-card and 3 voting
buttons
Interpreter equipment
IS 6032P
IS 6132P
LS 6032P
Interpreter Set
Interpreter Set
Interpreter Loudspeaker
MU 6040C/D
Microphone Unit for use with
customised front plate with
Loudspeaker, Microphone and
Buttons. Available in Delegate
(D) and Chairman (C) version
AM 6040
Ambient Noise Microphone
Manual 01 18 04466
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
Operating instructions
RP 6004 Repeater
Features
The main features of the RP 6004 Repeater are:
General description
·
4 outputs for connection to Delegate Units,
Interpreter Units etc.
The RP 6004 Repeater provides repeater and
splitter functionality for the DCS 6000 system.
·
Loop through connectors for connecting
additional RP 6004 or other units, which are
part of the DCS 6000 system.
One CU 6010 Central Unit is needed in each DCS
6000 system, however for expansion of the system
the RP 6004 Repeater is suitable.
·
Delayed switching on of power to the four
chains, to minimise the total ‘switch-on’ current
on the Mains supply.
The RP 6004 consist of the following main parts:
·
Repeater board with 4 individual repeated
outputs.
·
·
Designed in compact cabinet for easy installing
remotely.
Optional 19” brackets.
User Controls, indications & connectors
Front plate layout
The loop through connectors has auto-termination.
Front plate controls
The RP 6004 Repeater does not feature any controls
or displays, however the following indications and
connectors are available:
q
Repeated Chain 1, 2, 3 & 4
RJ45 connector, 4 pieces
DCS-LAN connectors. Used for connection to
DM/CM6xxx, CS6032, EX6010, AO6008, JB
6002/4 or IS6032 Interpreter Sets.
q
Loop through connectors
RJ45 connector, 2 pieces
DCS-LAN connectors. Used for connection to one
of the chain connector on the CU 6010 for repeating
the DCS-LAN chain.
Unused repeated chains do not need termination
The second connector is for connection to other
units with DCS-LAN connector, such as more RP
6004.
Manual 01 18 04466
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
q
Incoming data LED
q
Power LED
Those LED flashes, when the unit receives
incoming data from connected units on the
connector next to the LED.
Those LED light up when Power is available on the
connector next to the LED
System design
There are no settings to be done on the RP 6004
Repeater.
Repeater is repeating only one of the four outputs A
(A1 or A2) or B (B1 or B2) the max. number of
languages configured on the four outputs (1, 2, 3
and 4) is totally max. 16.
However it is important to observe, that the unit is
only repeating one of the chains on the CU 6010
Central Unit.
If more languages are required, Interpreter sets for
those languages have to be connected either to an
other RP 6004 Repeater, which is connected to the
other of the two chains (A or B) on the CU 6010, or
directly to the other of the two chains (A or B) on a
CU 6010.
And as so, the specification, which applies to each
of the chain outputs on the CU 6010 Central Units
does also apply to all the repeated outputs in total.
So when designing a system to incorporate RP 6004
Repeaters, bare in mind, that as the RP 6004
‘Repeated chain’ connector
When connecting the RP 6004 Repeaters to the CU
6010 the first RP 6004 is connected to the ‘Loop
through’ connector. The next RP 6004 Repeaters
can be connected to either the other ‘Loop through’
connector or to one of the ‘Repeated out’
connectors. If using the ‘Repeated’ outputs
maximum two more RP 6004 Repeaters can be
connected extending the maximum cable length in
one chain up to 650 m. The above schematic is
showing the connection using the ‘‘Repeated out’
connectors.
Manual 01 18 04466
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
‘Loop through’ connector
When connecting a number of RP 6004 Repeaters
to the CU 6010 an almost unlimited number of RP
6004 can be connected by using the ‘Loop through’
connector.
The practical limitation is the maximum cable
length in one chain, which is 200 m and supply of
power to the RP 6004 repeaters. The following
schematic is showing the connections using the
‘Loop through’ connectors.
A combination of the two methods of connection
can be seen in the ‘CU 6010 User Manual’.
Manual 01 18 04466
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
System Setup
General guidelines
Connect the RP 6004 to the various units using Cat
5 FTP or STP cables. Please observe the following
guide lines:
(B1 or B2) the max. number of languages
configured on the four outputs (1, 2, 3 and
4) is totally max. 16.
If more languages are required, Interpreter
sets for those languages have to be divided
between both chains (A or B) on the CU
6010. Normally the languages are supposed
to be divided equally on chains A (A1 or
A2) and B (B1 or B2).
·
Maximum cable length in one chain is 200
without repeater. This includes
interconnection cables between the units.
The max. usable cable length depends on
the units connected and length of feeding
cables etc.
m
·
If the last unit in one chain is a CS 6032
Channel Selector, this unit has to be
terminated with an external termination, as
the CS 6032 does not have an internal
termination.
·
·
Maximum cable length in one chain when
using repeaters is 650 m.
As the RP 6004 Repeater is repeating only
one of the four outputs A (A1 or A2) or B
Built into 19” Racks
The optional 19”-Brackets allow the unit to be
mounted in a rack with either the front (connector
side) or the blank backside to the front side of the
rack. The height is 1HU and allows units to be
stacked using only 44mm rack height.
Can also be mounted at the back of the rack cabinet
freeing the space at the front of the rack. The
cabinet shall then be deep enough to allow this.
Manual 01 18 04466
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
Typical schematics
The following schematics are showing various configurations:
Large sized conference microphone system
Manual 01 18 04466
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
Various configurations with RP 6004 Repeater and PS 6000 Power Supply
Manual 01 18 04466
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
Technical appendix
Pair 2: Pin 3 & 6
Pair 3: Pin 4 & 5
Pair 4: Pin 7 & 8
Cabling
CAT5
The phase of the pairs must be correct and the
wiring spec. as stated in CAT5 (EIA 568-B) have to
be followed.
The DCS 6000 system uses CAT5, CAT5e or
CAT6 FTP or STP cables with screened RJ45
connectors.
Note: CAT6 cables can normally only be
terminated in sockets (female) and not in cable
plugs. CAT6 should thus only be used for long
cable draws terminating in wall outlets or patch
panels.
It is important to use only FTP or STP
(screened) cables and screened RJ45 connectors
and not UTP cable, which is unscreened.
EIA 568-B wiring shall be used. How to wire a
CAT5 (EIA 568-B) Cable:
Accessories (not supplied)
Pin Function
Connector#1 Connector#2
1
2
3
4
5
6
7
8
In-going + ORG/WHT
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
Cat 5e Connection Cables (AWG24)
In-going -
+48V
0V
ORG
GRN/WHT
BLU
EC 6000-..5 Connection Cable 0,5 m ......................10 03 12500
EC 6000-01 Connection Cable 1 m .........................10 03 13101
EC 6000-02 Connection Cable 2 m .........................10 03 13201
EC 6000-05 Connection Cable 5 m .........................10 03 13501
EC 6000-10 Connection Cable 10 m .......................10 03 14102
EC 6000-20 Connection Cable 20 m .......................10 03 14202
EC 6000-50 Connection Cable 50 m .......................10 03 14502
Set of 1HU - 19” Brackets...........................................................
0V
+48V
BLU/WHT
GRN
Outgoing - BRN/WHT
Outgoing + BRN
BRN/WHT
BRN
Note. If other colour codes are used then the four
pairs are connected as follows:
Pair 1: Pin 1 & 2
Technical specifications
Dimensions (W x H x D) ..............................264 x 42 x 128 mm
Dimensions with 19” brackets...................482,6 x 44 x 128 mm
General
Power consumption ....................................................max. 10W
Temperature to guarantee specified performance
............................. 5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
Connectors
DCS-LAN loop through ........................................2 pieces RJ45
DCS-LAN repeated output ....................................4 pieces RJ45
..........................-20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight................................................................................... 1 kg
Specifications are subject to change without notice.
Manual 01 18 04466
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Danish Interpretation Systems
User Manual
Manual 01 18 04466
14
Download from Www.Somanuals.com. All Manuals Search And Download.
|