Listen Technologies Network Card RP 6004 User Manual

DCS 6000  
User Manual  
Digital Conference System  
RP 6004 Repeater  
Danish Interpretation Systems  
DIS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
List of Contents  
RP 6004 Repeater...........................................7  
List of Contents................................................. 3  
Document version.......................................... 3  
General description....................................... 7  
Features....................................................... 7  
User Controls, indications & connectors........ 7  
System design .............................................. 8  
Important ......................................................... 4  
Compliancy................................................... 4  
Installation precautions ................................. 4  
Cleaning ........................................................ 4  
Repacking...................................................... 4  
Warranty....................................................... 4  
System Setup...................................................10  
General guidelines........................................10  
Built into 19” Racks .....................................10  
Typical schematics .......................................11  
Description of the DCS 6000 system.................. 5  
Features......................................................... 5  
Large sized conference microphone system.. 11  
Various configurations with RP 6004 Repeater  
and PS 6000 Power Supply ......................... 12  
System components ....................................... 6  
Central equipment.........................................6  
Technical appendix .........................................13  
Interpreter equipment....................................6  
Conference equipment and channel selectors ..6  
Cabling...................................................... 13  
Accessories (not supplied) .......................... 13  
Operating instructions ...................................... 7  
Technical specifications................................13  
Document version  
Printed:  
Name:  
17-10-2004  
Version:  
C
RP6004-REV-C.DOC  
Copyright © 2003 Danish Interpretation Systems  
No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the  
publisher.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Important  
exposed to direct sunlight, excessive dust or  
humidity, mechanical vibration or shock.  
Compliancy  
The equipment has been tested and found to comply  
with the limits of the following standards for digital  
devices:  
To avoid moisture condensations do not install the  
unit where the temperature may rise rapidly.  
·
·
·
EN55103-1 (Emission)  
EN55103-2 (Immunity)  
FCC rules part 15, class A (Emission)  
Cleaning  
To keep the cabinet in its original condition,  
periodically clean it with a soft cloth. Stubborn  
stains may be removed with a cloth lightly  
dampened with a mild detergent solution. Never use  
organic solvents such as thinners or abrasive  
cleaners since these will damage the cabinet.  
This device complies with part 15 of the FCC rules.  
Operation is subject to the following conditions: (1)  
This device may not cause harmful interference,  
and (2) this device must accept any interference  
received, including interference that may cause  
undesired operation.  
Repacking  
These limits are designed to provide reasonable  
protection against harmful interference when the  
equipment is operated in a commercial or light  
industrial environment. The equipment generates,  
uses, and can radiate radio frequency energy and if  
not installed and used in accordance with the user  
manual it may cause harmful interference to radio  
communications.  
Save the original shipping cardboard box and  
packing material; they will become handy if you  
ever have to ship the unit. For maximum protection,  
re-pack the unit as originally packed from the  
factory.  
Warranty  
You are cautioned that any changes or  
modifications not expressly approved in this manual  
could void your authority to operate this equipment.  
The individual units in the DCS 6000 system are  
minimum covered by 12 months warranty against  
defects in materials or workmanship.  
Installation precautions  
Do not install the unit in a location near heat  
sources such as radiators or air ducts, or in a place  
.
Manual 01 18 04466  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Description of the DCS 6000 system  
RS232/RS422 connection on CU 6010 for  
external operation of the system of a PC or  
control system such as AMX or Crestron  
Features  
The DCS 6000 system has the following main  
features:  
The SW 6000 is an optional software package,  
which expands the functionality of the DCS 6000  
system. The software runs on standard computer  
technology (Standard PC with Windows 2000 or  
XP).  
·
·
·
Fully digital  
Excellent sound quality  
“State of the Art” fully digital integrated  
interpretation, discussion and voting system  
offering interpretation, language distribution,  
conference microphone and voting facilities  
with attendance check with Chip Card ™.  
Main features of the SW 6000 are:  
·
·
·
·
·
·
·
Microphone management  
Mimic panel operation  
Interpretation management  
Voting management  
Message handling  
·
·
New, unique digital DATA and AUDIO bus.  
39 incoming channels (8 floor channels + 31  
interpreted channels) and one Line input.  
·
·
33 distributed channels (2 x floor + 31  
interpreted channels)  
Agenda handling  
Data stored on SQL data base for easy  
export/import of data as well as easy links to  
external databases  
The Delegate and Interpreter units are powered  
and controlled by the CU 6010 Central Unit,  
which drives up to app. 200 units on 4 chains.  
·
·
Multi language user interfaces  
·
·
EX 6010 Extension Units or PS 6000 Power  
Supplies available if more units are required  
Supports different User types with different  
priorities, user interfaces and control  
possibilities  
A total of 4000 units (delegate and/or  
interpreter units) can be connected to the  
system.  
Variety of printing facilities such as speaker’s  
log, voting results, delegates list etc.  
·
·
Using screened CAT5 or CAT5e cabling (FTP  
or STP) ensuring a very cost effective  
installation and easy set-up of portable systems  
Firmware in Delegate units, Interpreter Units,  
Central Units etc. upgradeable through serial  
PC-connection (RS232 or RS422)  
·
·
Can be operated with or without a PC.  
Added functionality and comprehensive  
features provided by SW 6000 software  
package running on PC  
Manual 01 18 04466  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Conference equipment and channel  
selectors  
System components  
The CU 6010 Central Unit supports all available  
units in the DCS 6000 series:  
CS 6032FV/H  
CM/DM 6010P Conference Unit (portable)  
Channel Selector (flush mounted)  
CM/DM 6020P Conference Unit (portable) with  
XLR microphone connector  
Central equipment  
CM/DM 6070P Conference Unit (portable) with  
two built-in channel selectors  
CM/DM 6090P Conference Unit (portable) with  
two built-in channel selectors and  
CU 6010  
EX 6010  
PS 6000  
RP 6004  
AO 6008  
JB 6002  
JB 6004  
Central Unit  
Extension Power Unit  
Power Supply  
Repeater for four chains  
Audio Output box  
Junction Box with 2 outputs  
Junction Box with 4 outputs  
XLR microphone connector  
CM/DM 6060F Conference Unit (flush mounted)  
with one built-in channel  
selectors  
CM/DM 6510F Conference Unit (flush mounted)  
with Chip-card and 3 voting  
buttons  
CM/DM 6560F Conference Unit (flush mounted)  
with one built-in channel  
selector, Chip-card and 3 voting  
buttons  
Interpreter equipment  
IS 6032P  
IS 6132P  
LS 6032P  
Interpreter Set  
Interpreter Set  
Interpreter Loudspeaker  
MU 6040C/D  
Microphone Unit for use with  
customised front plate with  
Loudspeaker, Microphone and  
Buttons. Available in Delegate  
(D) and Chairman (C) version  
AM 6040  
Ambient Noise Microphone  
Manual 01 18 04466  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Operating instructions  
RP 6004 Repeater  
Features  
The main features of the RP 6004 Repeater are:  
General description  
·
4 outputs for connection to Delegate Units,  
Interpreter Units etc.  
The RP 6004 Repeater provides repeater and  
splitter functionality for the DCS 6000 system.  
·
Loop through connectors for connecting  
additional RP 6004 or other units, which are  
part of the DCS 6000 system.  
One CU 6010 Central Unit is needed in each DCS  
6000 system, however for expansion of the system  
the RP 6004 Repeater is suitable.  
·
Delayed switching on of power to the four  
chains, to minimise the total ‘switch-on’ current  
on the Mains supply.  
The RP 6004 consist of the following main parts:  
·
Repeater board with 4 individual repeated  
outputs.  
·
·
Designed in compact cabinet for easy installing  
remotely.  
Optional 19” brackets.  
User Controls, indications & connectors  
Front plate layout  
The loop through connectors has auto-termination.  
Front plate controls  
The RP 6004 Repeater does not feature any controls  
or displays, however the following indications and  
connectors are available:  
q
Repeated Chain 1, 2, 3 & 4  
RJ45 connector, 4 pieces  
DCS-LAN connectors. Used for connection to  
DM/CM6xxx, CS6032, EX6010, AO6008, JB  
6002/4 or IS6032 Interpreter Sets.  
q
Loop through connectors  
RJ45 connector, 2 pieces  
DCS-LAN connectors. Used for connection to one  
of the chain connector on the CU 6010 for repeating  
the DCS-LAN chain.  
Unused repeated chains do not need termination  
The second connector is for connection to other  
units with DCS-LAN connector, such as more RP  
6004.  
Manual 01 18 04466  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
q
Incoming data LED  
q
Power LED  
Those LED flashes, when the unit receives  
incoming data from connected units on the  
connector next to the LED.  
Those LED light up when Power is available on the  
connector next to the LED  
System design  
There are no settings to be done on the RP 6004  
Repeater.  
Repeater is repeating only one of the four outputs A  
(A1 or A2) or B (B1 or B2) the max. number of  
languages configured on the four outputs (1, 2, 3  
and 4) is totally max. 16.  
However it is important to observe, that the unit is  
only repeating one of the chains on the CU 6010  
Central Unit.  
If more languages are required, Interpreter sets for  
those languages have to be connected either to an  
other RP 6004 Repeater, which is connected to the  
other of the two chains (A or B) on the CU 6010, or  
directly to the other of the two chains (A or B) on a  
CU 6010.  
And as so, the specification, which applies to each  
of the chain outputs on the CU 6010 Central Units  
does also apply to all the repeated outputs in total.  
So when designing a system to incorporate RP 6004  
Repeaters, bare in mind, that as the RP 6004  
‘Repeated chain’ connector  
When connecting the RP 6004 Repeaters to the CU  
6010 the first RP 6004 is connected to the ‘Loop  
through’ connector. The next RP 6004 Repeaters  
can be connected to either the other ‘Loop through’  
connector or to one of the ‘Repeated out’  
connectors. If using the ‘Repeated’ outputs  
maximum two more RP 6004 Repeaters can be  
connected extending the maximum cable length in  
one chain up to 650 m. The above schematic is  
showing the connection using the ‘‘Repeated out’  
connectors.  
Manual 01 18 04466  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
‘Loop through’ connector  
When connecting a number of RP 6004 Repeaters  
to the CU 6010 an almost unlimited number of RP  
6004 can be connected by using the ‘Loop through’  
connector.  
The practical limitation is the maximum cable  
length in one chain, which is 200 m and supply of  
power to the RP 6004 repeaters. The following  
schematic is showing the connections using the  
‘Loop through’ connectors.  
A combination of the two methods of connection  
can be seen in the ‘CU 6010 User Manual’.  
Manual 01 18 04466  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
System Setup  
General guidelines  
Connect the RP 6004 to the various units using Cat  
5 FTP or STP cables. Please observe the following  
guide lines:  
(B1 or B2) the max. number of languages  
configured on the four outputs (1, 2, 3 and  
4) is totally max. 16.  
If more languages are required, Interpreter  
sets for those languages have to be divided  
between both chains (A or B) on the CU  
6010. Normally the languages are supposed  
to be divided equally on chains A (A1 or  
A2) and B (B1 or B2).  
·
Maximum cable length in one chain is 200  
without repeater. This includes  
interconnection cables between the units.  
The max. usable cable length depends on  
the units connected and length of feeding  
cables etc.  
m
·
If the last unit in one chain is a CS 6032  
Channel Selector, this unit has to be  
terminated with an external termination, as  
the CS 6032 does not have an internal  
termination.  
·
·
Maximum cable length in one chain when  
using repeaters is 650 m.  
As the RP 6004 Repeater is repeating only  
one of the four outputs A (A1 or A2) or B  
Built into 19” Racks  
The optional 19”-Brackets allow the unit to be  
mounted in a rack with either the front (connector  
side) or the blank backside to the front side of the  
rack. The height is 1HU and allows units to be  
stacked using only 44mm rack height.  
Can also be mounted at the back of the rack cabinet  
freeing the space at the front of the rack. The  
cabinet shall then be deep enough to allow this.  
Manual 01 18 04466  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Typical schematics  
The following schematics are showing various configurations:  
Large sized conference microphone system  
Manual 01 18 04466  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Various configurations with RP 6004 Repeater and PS 6000 Power Supply  
Manual 01 18 04466  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Technical appendix  
Pair 2: Pin 3 & 6  
Pair 3: Pin 4 & 5  
Pair 4: Pin 7 & 8  
Cabling  
CAT5  
The phase of the pairs must be correct and the  
wiring spec. as stated in CAT5 (EIA 568-B) have to  
be followed.  
The DCS 6000 system uses CAT5, CAT5e or  
CAT6 FTP or STP cables with screened RJ45  
connectors.  
Note: CAT6 cables can normally only be  
terminated in sockets (female) and not in cable  
plugs. CAT6 should thus only be used for long  
cable draws terminating in wall outlets or patch  
panels.  
It is important to use only FTP or STP  
(screened) cables and screened RJ45 connectors  
and not UTP cable, which is unscreened.  
EIA 568-B wiring shall be used. How to wire a  
CAT5 (EIA 568-B) Cable:  
Accessories (not supplied)  
Pin Function  
Connector#1 Connector#2  
1
2
3
4
5
6
7
8
In-going + ORG/WHT  
ORG/WHT  
ORG  
GRN/WHT  
BLU  
BLU/WHT  
GRN  
Cat 5e Connection Cables (AWG24)  
In-going -  
+48V  
0V  
ORG  
GRN/WHT  
BLU  
EC 6000-..5 Connection Cable 0,5 m ......................10 03 12500  
EC 6000-01 Connection Cable 1 m .........................10 03 13101  
EC 6000-02 Connection Cable 2 m .........................10 03 13201  
EC 6000-05 Connection Cable 5 m .........................10 03 13501  
EC 6000-10 Connection Cable 10 m .......................10 03 14102  
EC 6000-20 Connection Cable 20 m .......................10 03 14202  
EC 6000-50 Connection Cable 50 m .......................10 03 14502  
Set of 1HU - 19” Brackets...........................................................  
0V  
+48V  
BLU/WHT  
GRN  
Outgoing - BRN/WHT  
Outgoing + BRN  
BRN/WHT  
BRN  
Note. If other colour codes are used then the four  
pairs are connected as follows:  
Pair 1: Pin 1 & 2  
Technical specifications  
Dimensions (W x H x D) ..............................264 x 42 x 128 mm  
Dimensions with 19” brackets...................482,6 x 44 x 128 mm  
General  
Power consumption ....................................................max. 10W  
Temperature to guarantee specified performance  
............................. 5 Deg C. to 40 Deg C. (35 to 80% humidity)  
Storage temperature  
Connectors  
DCS-LAN loop through ........................................2 pieces RJ45  
DCS-LAN repeated output ....................................4 pieces RJ45  
..........................-20 Deg C. to 60 Deg C. (10 to 80% humidity)  
Weight................................................................................... 1 kg  
Specifications are subject to change without notice.  
Manual 01 18 04466  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Danish Interpretation Systems  
User Manual  
Manual 01 18 04466  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Weather Radio WS 7014U IT User Manual
Lasko Humidifier 1128 User Manual
Lennox Hearth Fire Pit HCI 36 H User Manual
Lenovo Laptop 2518X01 User Manual
Link electronic Network Router 861 XL818G User Manual
LST Smoke Alarm BC016 2 User Manual
Mabe Canada Refrigerator GWS04 User Manual
Makita Drill 6203D User Manual
Memorex Flat Panel Television MLT4221P User Manual
Metra Electronics Speaker 95 7332 User Manual