Lightwave Communications Server SCS3230 User Manual

SCS3230  
SSH Option for Console Server 3200  
System Administrator's Guide  
Lightwave Communications, Inc.  
NOTE: Use this Guide and the ConsoleServer 3200 Manual, PN 15.00.017 for any new installation  
Part Number 15.00.038  
Revision A  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
Disclaimer & Revisions  
Operation of this equipment in a residential area is likely to cause interference in which case the user,  
at his or her own expense, will be required to take whatever measures may be required to correct the  
interference.  
Attention: This product has been designed to comply with the limits for a Class A  
digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide  
reasonable protection against such interference when operating in a commercial  
environment. This equipment generates, uses, and can radiate radio frequency energy,  
and if not installed and used in accordance with this guide, may cause harmful  
interference to radio communications.  
Changes or modifications to this device not explicitly approved by Lantronix will void the user's  
authority to operate this device.  
The information in this guide may change without notice. The manufacturer assumes no  
responsibility for any errors that may appear in this guide.  
Date  
Rev.  
Part No. Comments  
April  
A
15.00.038 System Administrator's Guide for SCS3230, an optional  
enhancement to the ConsoleServer 3200 system.  
Incorporated Addendum info on root-level password, and binary  
update file location (pp.9, 25, 39).  
2002 (Preliminary)  
May  
2002  
A
15.00.038  
iii  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
Declaration of Conformity  
(according to ISO/IEC Guide 22 and EN 45014)  
Manufacturer’s Name & Address:  
Lightwave Communications, a Lantronix Company  
100 Washington Street, Milford, CT 06460 USA  
Declares that the following product:  
Product Name & Model: Lightwave Console Server 3200  
Conforms to the following standards or other normative documents:  
Safety:  
EN60950:  
1992+A1, A2, A3, A4, A11  
Electromagnetic Emissions:  
EN55022 Class A:  
1998 (CISPR 22, Class A: 1993, A1: 1995, A2: 1996)  
2000  
1994  
EN1000-3-2/A14:  
EN10003-3:  
Electromagnetic Immunity:  
EN55024: 1998 Information Technology Equipment-Immunity Characteristics:  
EN61000-4-2:  
1995 Electro-Static Discharge Test  
1996 Radiated Immunity Field Test  
1995 Electrical Fast Transient Test  
1995 Power Supply Surge Test  
1996 Conducted Immunity Test  
1993 Magnetic Field Test  
EN61000-4-3:  
EN61000-4-4:  
EN61000-4-5:  
EN61000-4-6:  
EN61000-4-8:  
EN61000-4-11:  
1994 Voltage Dips & Interrupts Test  
Supplementary Information:  
This Class A digital apparatus complies with Canadian ICES-003 (CSA) and has been verified as  
being compliant within the Class A limits of the FCC Radio Frequency Device Rules (FCC Title 47,  
Part 15, Subpart B CLASS A), measured to CISPR 22: 1993 limits and methods of measurement of  
Radio Disturbance Characteristics of Information Technology Equipment. This product also complies  
with the requirements of the Low Voltage Directive 72/23/EEC and the EMC Directive 89/336/EEC.  
The Console Server 3200 carries the CE mark since it has been tested and found compliant with the  
following standards:  
Safety:  
EN 60950  
Emissions:  
Immunity:  
EN 55022 Class A  
EN 55024  
Rev. A  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
Table of Contents  
SCS3230 System Administrator's Guide  
1: Product Description ______________________________________________________9  
1.1  
1.2  
1.3  
1.4  
1.5  
Quick Start _____________________________________________________9  
Upgrade Description _____________________________________________ 10  
System Features ________________________________________________ 10  
Hardware Features_______________________________________________ 11  
3230 Network/Control Card________________________________________ 12  
1.5.1 10/100 Port (Network) ______________________________________ 14  
1.5.2 TERM Port (Console)_______________________________________ 15  
Backup and Restore Commands _____________________________________ 15  
1.6  
2: System Overview________________________________________________________16  
2.1  
2.2  
2.3  
2.4  
2.5  
Connect Up to Thirty-two RS-232C Compatible Ports_____________________ 16  
128K FIFO Audit Trail ___________________________________________ 16  
Connections ___________________________________________________ 16  
Security Passwords ______________________________________________ 17  
Interface ______________________________________________________ 17  
3: System Components _____________________________________________________18  
3.1  
3200 Chassis ___________________________________________________ 18  
3.1.1 Power Supply Module ______________________________________ 18  
3.1.2 3200 Switch Cards _________________________________________ 18  
Device Cards___________________________________________________ 19  
Access Cards___________________________________________________ 19  
3.3.1 NETWORK / CONTROL Card________________________________ 19  
3.3.2 CHANNEL EXTENDER Cards _______________________________ 20  
3.3.3 TERMINAL Cards_________________________________________ 20  
3.3.4 3200 Network Cards________________________________________ 20  
3.3.5 3200 10/100 Network Cards __________________________________ 21  
3.3.6 Modem Card _____________________________________________ 21  
3.2  
3.3  
4: Installation Instructions __________________________________________________22  
4.1  
4.2  
Items in a SCS3230 Kit ___________________________________________ 22  
Move Database from your CS3200 to SCS3230__________________________ 23  
4.2.1 Backup Procedure of your CS3200 System _______________________ 23  
4.2.2 Restore Procedure _________________________________________ 23  
4.2.3 To RESTORE from a 3200 to a 3230____________________________ 24  
4.2.4 LCI Update ______________________________________________ 25  
Connecting to the TERM Port ______________________________________ 26  
4.3  
5: Connecting Equipment to the SCS3230 _____________________________________27  
5.1  
5.2  
5.3  
5.4  
Terminal Card__________________________________________________ 27  
NETWORK / CONTROL Card _____________________________________ 28  
Modem Card___________________________________________________ 28  
Device Card ___________________________________________________ 29  
15.00.038  
v
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
6: SCS3230 Setup Script and System Administration ___________________________33  
6.1  
Power-up Sequence and Basic Use of the Administrator Functions ___________ 34  
6.1.1 Logging In, Serial Connection_________________________________ 35  
6.1.2 Logging In, Network Connection ______________________________ 35  
6.1.3 Logging Out______________________________________________ 36  
6.1.4 System Help (Command List) _________________________________ 37  
6.1.5 Abbreviations_____________________________________________ 38  
Sys Admin vs. root access _________________________________________ 39  
Setup Script____________________________________________________ 40  
6.3.1 Hostname and IP Address____________________________________ 41  
6.3.2 Timezone (Clock)__________________________________________ 44  
6.3.3 Configure DNS ___________________________________________ 46  
6.3.4 Hosts___________________________________________________ 48  
6.3.5 Services_________________________________________________ 49  
6.3.6 Syslog __________________________________________________ 50  
6.3.7 SSH Logins______________________________________________ 51  
6.3.8 TELNET logins ___________________________________________ 52  
6.3.9 NTP Daemon_____________________________________________ 52  
6.3.10 Configure the Firewall _____________________________________ 53  
6.3.11 Firewall Reject Method_____________________________________ 55  
6.3.12 Ping Attempts ___________________________________________ 55  
6.3.13 Confirm Changes _________________________________________ 57  
6.3.14 SAVE Command _________________________________________ 58  
6.2  
6.3  
7: Creating and Managing Users_____________________________________________59  
7.1  
7.2  
7.3  
7.4  
Adding a User ID _______________________________________________ 59  
Editing a User ID________________________________________________ 61  
Listing User IDs ________________________________________________ 61  
Deleting a User ID_______________________________________________ 63  
7.5 DevicesCommand_____________________________________________ 63  
7.6 TerminalsCommand___________________________________________ 65  
7.7 NetworkCommands ____________________________________________ 65  
7.8 ModemCommand _______________________________________________ 66  
7.9  
Status Commands _______________________________________________ 67  
7.9.1 CONNECTIONSCommand___________________________________ 67  
7.9.2 LISTCARDSCommand _____________________________________ 68  
7.9.3 VERSIONCommand _______________________________________ 68  
7.9.4 INFOCommand __________________________________________ 69  
7.9.5 POWERSTATUSCommand___________________________________ 70  
7.9.6 LOGCommand____________________________________________ 70  
Sys Admin Session Management Commands ___________________________ 71  
7.10.1 LINESPERPAGECommand_________________________________ 72  
7.10.2 TIMEOUTCommand ______________________________________ 72  
Breaking User Connections ________________________________________ 72  
7.11.1 BREAKCommand ________________________________________ 73  
7.11.2 FORCELOGOUTCommand__________________________________ 73  
7.11.3 TELNETTIMEOUTCommand _______________________________ 74  
7.11.4 MODEMTIMEOUTCommand_________________________________ 74  
7.10  
7.11  
Rev. A  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
8: User Access and Interface ________________________________________________75  
8.1  
8.2  
8.3  
Terminal Card__________________________________________________ 75  
Network Card __________________________________________________ 75  
Modem Card___________________________________________________ 76  
8.3.1 The ByeCommand ________________________________________ 76  
Overview of Commands___________________________________________ 77  
Logging In and Changing Passwords _________________________________ 79  
Logging Out ___________________________________________________ 80  
Checking Connections ____________________________________________ 80  
Selecting a Device Port ___________________________________________ 81  
Listening to a Server Session _______________________________________ 82  
F2 PULL-DOWN MENU TO LISTEN TO A DEVICE PORT PART 2 ________ 83  
Direct Mode ___________________________________________________ 84  
8.10.1 Direct Mode Escape Sequence _______________________________ 84  
Using the Buffer ________________________________________________ 85  
8.4  
8.5  
8.6  
8.7  
8.8  
8.9  
8.10  
8.11  
9: The Break Generation Sequence___________________________________________88  
10: Displaying System Information___________________________________________89  
11: Front Panel Display Information: _________________________________________90  
12: Appendix A – Command Abbreviations ___________________________________94  
13: Appendix B – Hexadecimal ASCII Code ___________________________________96  
15.00.038  
vii  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
For Your Notes  
Rev. A  
viii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
1: Product Description  
The SCS3230 is a ConsoleServer 3200 (or CS3200) that has been upgraded for enhanced  
security and control capabilities, including SSH capabilities required for today's secure server  
environment, and network features such as LDAP and NIS. The upgrade is available as a kit, or  
the individual parts (cards, cables, etc.) can be ordered separately.  
MODEM  
TERMINAL NETWORK TERMINAL NETWORK SWITCH  
SWITCH  
DEVICE  
DEVICE  
DEVICE  
DEVICE  
DEVICE  
DEVICE  
DEVICE  
DEVICE  
CONTROL  
I
0
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
A
I
0
B
Fig. 1 Rear View of original Console Server 3200 - notice Control Card to far right  
The SCS3230 upgrade replaces the CONTROL card of the 3200 with a new 10/100 BaseT  
NETWORK and CONTROL card which includes a Linux-based operating system, and also  
replaces the NETWORK and TERMINAL cards of the 3200 with CHANNEL EXTENDER cards.  
1.1 Quick Start  
Overview of Upgrading from a CS3200 to a SCS3230 (all covered in this manual):  
1. Backup the Database of your existing CS3200 System.  
2. Obtain the SCS3230 Kit, which includes the cards, cables and this manual.  
3. Locate the firmware updates for the DEVICE cards; they are stored in the /lci/bin  
directory on the NETWORK/CONTROL card. You may also download the update files  
from the Lightwave FTP site. DEVICE cards MUST be updates to Version 4.03 firmware.  
4. Remove the CS3200 from service.  
5. Remove the CONTROL card, the TERMINAL card(s) and the Network or 10/100 card(s)  
6. Install the 3230's NETWORK/CONTROL card in place of the CONTROL card.  
7. Install the four CHANNEL EXTENDERS in place of the TERMINAL or NETWORK cards.  
8. Connect the four cables for the CHANNEL EXTENDERS.  
9. Turn the System On, and administer the system using the TERM port. Set up your IP  
network connection information to get that operating.  
10. RESTORE your CS3200's database into the SCS3230 system.  
The SCS3230 system should be fully operational at this point.  
15.00.038  
- 9 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
1.2 Upgrade Description  
The SCS3230 uses most of the same cards as the CS3200, and uses the CS3200 chassis. The  
SCS3230 is below. Notice the SCS3230's NETWORK/CONTROL card to the far right.  
NETWORK/  
CONTROL  
MODEM CHANNEL CHA NNEL CHANNE L TERMIN AL SWITCH SWITCH DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE  
EXTEND ER EXTENDER EXTENDER  
T
E
R
M
A
B
C
D
A
B
C
D
A
B
A
B
C
D
A
B
C
D
A
B
A
B
C
D
A
B
C
D
A
B
C
H
A
N
N
E
L
E
X
T
E
N
D
E
R
S
C
D
C
D
C
D
N
E
T
10/100  
Caution! Replace with same type and rating fuse.  
100-240V ~, 1A, 50/60 Hz  
T
4A, 250 VAC  
Fig. 2 Rear View of SCS3230 - notice the NETWORK / CONTROL card in far right slot.  
Also note that this diagram shows three (3) Channel Extenders and one Terminal card in  
slots B through E, and 8 DEVICE cards.  
1.3 System Features  
The SCS3230 system is a Linux-based Console Server offering secure IP network-based  
connections to up to 32 connected devices via EIA-232 protocol. Linux administrators will find  
familiar commands and should need little guidance on administering the SCS3230 to co-operate  
in their server installation.  
System users will not encounter any differences in operation. The commands and functions of  
the SCS3230 are designed to minimize any conversion issues.  
The SCS3230 offers the following important features (many of which are also found in the  
CS3200 product):  
·
·
·
·
·
·
·
·
·
·
·
·
Hot-Swappable cards  
Dual Redundant Power Supplies  
10/100 IP Network Interface  
Connect up to 32 RS-232 serial devices  
ID / Password Security, configurable access rights  
OpenSSH version 2 security  
Open LDAP  
NIS capable for remote database rights  
No unintentional break will ever be sent to attached servers  
Local access through TERMport (the 3230's Console port)  
Field upgradeable Flash memory  
User programming interface for simple administration and setup  
Rev. A  
- 10 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
1.4 Hardware Features  
·
·
·
·
·
·
·
·
·
·
3RU tall (5-1/4 inches) rack-mountable Server  
One (1) 10/100 baseT Network Port for connection to your IP network  
Up to 32 serial DEVICE ports, RS232, connected via Category 5 (RJ45) wiring  
One (1) serial TERMINAL port, for VT100 console or PC with emulation  
128KB-per-port Buffer Memory for DEVICE ports  
Front Panel multi-line backlit LCD display and pushbutton controls  
128MB FLASH Memory, 128MB RAM  
* Redundant Power Inputs (chassis dependant)  
Optional Analog Modem for dial up access (non-secure)  
Power Options: Universal AC (100-240V) or -48VDC  
* Some early CS3200 Chassis employ a single AC Power Input module. The Power Module is  
field-replaceable to provide redundant power capabilities, if required.  
The SCS3230 is one of the most versatile network administration tools available today,  
allowing as many as 17 simultaneous users to access up to 32connected devices via  
the RS-232C serial protocol. Pull-down menus help users navigate through all the  
functions of the SCS3230, creating an easy-to-use way to access system resources.  
The SCS3230 consists of eight device card slots, two switch card slots, four access card slots,  
one modem slot and one Network/Control slot. The power supply slot contains two independent  
power supplies for redundant operation. The basic system consists of the power supply  
module, two switch cards, the Network / Control card, and in most cases, four Channel Extender  
Cards. The remaining card slots are populated according to the application requirements.  
All system parameters are stored in non-volatile data flash memory. This data flash memory is  
organized such that there is always a complete copy of all data. Typical stored information  
includes the users’ identities, user passwords, port parameters (such as baud rate, device  
name, etc.) and other system information. The data flash memory allow for a maximum of 200  
user profiles to be stored, along with the parameters for all cards. System parameters may be  
backed up and restored from a local serial connection.  
An important feature of the SCS3230 is the ability to re-configure the system hardware and  
software without turning off the power. The system boards have circuitry that allows them to be  
'hot swapped' so the system may be expanded at any time while in use.  
System updates can be accomplished via software upload to the system. For most updates, the  
system need not be restarted or taken out of service. Some operations or updates (e.g.,  
Network update) may require the network ports be restarted.  
15.00.038  
- 11 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
1.5 3230 Network/Control Card  
The SCS3230 offers the following benefits and features over the conventional CS3200 product:  
·
·
·
·
Linux-based Secure Console Server using OpenSSH v2  
ID / Password Security, configurable access rights  
One RS-232 Terminal port (for your local Console)  
10/100 Network Port (TCP/IP) -- an option for the CS3200  
TERM (Console) connector,  
RJ45, for RS232 terminal  
Four CHANNEL EXTENDER  
ports - use four (4) CAT5 cables  
to individual  
FLASH  
Memory  
Device  
Channel Extender cards  
NETWORK 10/100 BaseT  
IP network connection  
The SCS3230 replaces the standard CONTROL card with the new combination NETWORK /  
CONTROL card, and fills the four Network / Terminal Card slots with "Channel Extender" cards.  
The Channel Extenders are used by the new Network / Control card to extend the number of  
Rev. A  
- 12 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
channels available to the 10/100 IP network connection. [The Channel Extender cards are the  
same as those used with the CS3200's 10/100 Network card.]  
The NETWORK / CONTROL Card replaces the CONTROL card (far right slot) in 3200  
The (4) Channel Extenders are used in place of the NETWORK or TERMINAL cards.  
15.00.038  
- 13 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
Four (4) 24-inch long CAT5 cables (PN 200.1061; straight-through, fully pinned) are used  
between the Channel Extenders and the NETWORK / CONTROL card. One cable is used to  
connect each of the Channel Extenders in Slots B through E to the corresponding port (see  
below) on the new Network/Control Card.  
NETWORK/  
CONTROL  
MODEM CHANNEL CHANNEL CHANNEL TERMINAL SWITCH SWI TCH DE VICE DEVI CE DE VICE DEVI CE DEV ICE DEVICE DEVI CE DE VICE  
EXT ENDER EXTENDER EXTENDER  
T
E
R
M
A
B
C
D
A
B
C
D
A
B
C
D
A
B
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
H
A
N
N
E
L
E
X
T
E
N
D
E
R
S
C
D
C
D
N
E
T
10/100  
Caution! Replace with same type and rating fuse.  
100-240V ~, 1A, 50/60 Hz  
T
4A, 250 VAC  
If a Terminal Card remains in the 3230 system, that Channel Extender port of the Network /  
Control Card is not used. Shown above, Network Slot E's Channel Extender position is  
"unused"; and this unnecessary cable would not be installed in that position.  
1.5.1 10/100 Port (Network)  
The 10/100 BaseT Network connection is accessible on the bottom RJ45 connector on the  
NETWORK / CONTROL card.  
Rev. A  
- 14 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
1.5.2 TERM Port (Console)  
A Terminal port, or Console (labeled TERM) is available at the top RJ45 connector on the  
NETWORK / CONTROL Card. This is an EIA-232-compliant terminal position, typically used for  
System Administration purposes.  
The TERM port on the NETWORK/CONTROL card is fixed at 9600 baud, 8 data bits, No Parity,  
and one Stop bit (9600 / 8 / N / 1) and is a DCE device.The TERM port has a higher Terminal  
priority than the 10/100 Network Port on this card, and can be used for forced logout of  
abandoned or other undesirable connections.  
1.6 Backup and Restore Commands  
The SCS3230 system is fully compatible with the "Backup and Restore" capabilities of the  
CS3200, so transferring your user database from your existing CS3200 into the new SCS3200  
hardware is supported.  
15.00.038  
- 15 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
2: System Overview  
For simplicity, we will discuss the features and capabilities of the SCS3230 as if it were a new  
and different system, not merely an upgrade to a ConsoleServer 3200. The SCS3230 is  
designed to operate as closely to the original ConsoleServer3200 as possible from a user's  
perspective, but still provide the capabilities needed for the secure server environment.  
Existing 3200 customers maintain their investment and can offer enhanced security and control  
for their terminal server systems. Existing users will not require retraining since all commands  
and features of the SCS3230 option are the same as found in the CS3200. Even the upgrade  
process accepts the existing site database for rapid deployment of the SCS3230 equipment.  
2.1 Connect Up to Thirty-two RS-232C Compatible Ports  
The SCS3230 is plug-compatible with any RS-232C device, DTE or DCE. These include a  
variety of network servers, routers, or any other LAN/WAN computers on the network.  
Connections are made by routing the device signals through the switch cards to the appropriate  
user interface port.  
2.2 128K FIFO Audit Trail  
The SCS3230 stores the equivalent of approximately 200 screens worth of data (128K) per  
device port in a true FIFO buffer for each DEVICE port. This data may be viewed 'off-line' at  
any time by users accessing the device port buffer.  
Should more than 128K of data be received in a buffer, the oldest data will be discarded, in the  
amount of the 'overflow'. By operating in this fashion, the most recent data is collected and the  
largest amount of data that can be saved will be maintained.  
2.3 Connections  
The system is capable of 17 simultaneous full-duplex connections to the connected devices.  
The administration functions may be accessed through a local serial connection or through a  
network connection. The NETWORK / CONTROL card (with a full complement of four Channel  
Extender cards) supports up to 16 users connections plus one connection to the administration  
functions. The NETWORK / CONTROL card also provides one TERM port (for a System  
Administrator's serial Console)  
The TERMINAL cards (a 3200 access card) may be used for applications requiring additional  
local serial terminals. Each Terminal Card is installed in place of one of the Channel Extender  
Rev. A  
- 16 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
cards. By reducing the number of Channel Extender ports, the maximum number of available  
connections for 10/100 network access is reduced by four sessions for each Terminal Card  
installed. Illustrations showing a mixture of Channel Extender cards and Terminal Cards are  
found on pages 11 and 16 of this Guide.  
An optional MODEM connection is also available, however its connections are not 'secure' and  
its use is not recommended except in those instances when security will not be compromised by  
dial-in access using the modem. The SCS3230's modem connection is not subject to the Linux  
security controls of the other access ports.  
2.4 Security Passwords  
The System Administrator may define up to 200 user profiles. Each user is assigned a unique  
password by the system administrator. The system forces the user to change the password the  
first time the user attempts to connect to any servers. After the users have changed their  
passwords, the system will not prompt for a change. The users change their passwords at  
whatever interval they feel is necessary.  
The operating system is subject to Linux security constraints, including sysadmin and root level  
security. Users cannot access the sysadmin layer or the root layer of the system.  
2.5 Interface  
Interfaces to the DEVICE and TERMINAL cards are all RS-232C compliant. These ports are  
configured through the TERM port on the NETWORK / CONTROL card using a local Console,  
or via network connection through your TCP/IP network. All system access is password  
protected.  
Each DEVICE port and TERMINAL has settings for baud rate, stop bits, parity, number of data  
bits, flow control, and port type (i.e., DTE or DCE). The TERM port (for your Console) on the  
NETWORK / CONTROL card has a fixed data format of 9600 / 8/ N / 1, and DCE.  
The NETWORK / CONTROL card connects over a network using TCP/IP on 10- or 100-baseT  
at 10/100 Mbits (auto-negotiating). The 10/100 port on this card is assigned an IP address, a  
subnet mask, a default gateway, and an optional secondary destination path by Console  
configuration using the TERM port on this card during the initial setup of the system.  
The optional MODEM card connects directly to a conventional modular phone jack (RJ11) to  
interface with a telephone network. The sys admin may designate a modem initialization string,  
or may use the default modem initialization string, which allows auto-answering on one ring. The  
modem provides card-edge visual status indicators.  
Note:For 'secure' installations, the Modem should not be used. Modem access is not  
encrypted and/or secure and could allow unauthorized access to system information. However,  
if modem access is limited to internal administrative access, the modem may provide an  
additional means of system access in the event your network is down.  
15.00.038  
- 17 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
3: System Components  
Each SCS3230 consists of three major components: the 3200 system chassis, 3200 DEVICE  
cards, and 3200 access cards. The 'access cards' include the new 3230 NETWORK/CONTROL  
card, which is the heart of the SCS3230 product, and makes it operate a bit differently.  
Note: The 3200's NETWORK card and 10/100 Network card are NOT supported by the  
SCS3230 NETWORK / CONTROL card. The NETWORK/CONTROL card incorporates its own  
10/100 Network port.  
3.1 3200 Chassis  
The chassis contains a front-panel LCD for quick system information that is available at all  
times. Two front panel buttons allow display selection and paging through displays (see  
section 10.0 for more information).  
The second major component of the chassis is the power supply module. This module contains  
two independent supplies, each capable of sustaining the system should one supply fail or lose  
its power input. The Power Supply module also incorporates the system fan. The AC power  
module has two front-panel switches (one for each supply) with replaceable fuses in their IEC-  
type connectors. The DC power module provides a single On/Off switch.  
The third and last component of the chassis is the SWITCH card set. The switch cards connect  
the access cards to the device cards, with a maximum of 17 simultaneous connections using all  
available terminal, network, and modem ports.  
3.1.1 Power Supply Module  
The SCS3230 may be equipped with either an AC power module or a DC power module. The  
power module may be field-swapped (although is not hot-swappable) if the available power  
source requirements change.  
The Power Module provides two discrete electrical inputs to the system. Either power input  
supports a fully-loaded chassis, and switching between power inputs is automatic if one source  
fails or is turned off.  
3.1.2 3200 Switch Cards  
Two 3200 SWITCH Cards are required, and are unchanged from the 3200 system.  
Rev. A  
- 18 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
3.2 Device Cards  
The Device cards are fully compatible with the SCS3230 application. The SCS3230 requires  
version 4.03 Build 01 (or higher) of the Device Card binary firmware. Firmware updates are  
downloadable from the Lightwave FTP site (ftp://ftp.lightwavecom.com).  
Note: DEVICE CARD firmware MUST be updated to 4.03 or higher  
Each DEVICE card has four completely independent ports for attachment to servers or other  
devices with console ports. Eight device cards may be installed per system, for a maximum of  
32 device ports. The device ports do not send an 'break' signal to the attached servers at any  
time unless specified by the user. There are no adjustments directly on the device cards. All  
parameters are set up through the system administrator port.  
3.3 Access Cards  
The card configuration is changed with the SCS3230, compared to CS3200.  
3.3.1 NETWORK / CONTROL Card  
The NETWORK / CONTROL card allows  
users to connect to the device cards from  
an SSH or telnet session over an IP  
network, and remote access to the  
administration functions.  
The NETWORK  
/
CONTROL card  
replaces the CONTROL card from the  
CS3200, and is located in the far right slot  
of the system chassis. Only one card is  
required in an SCS3230.  
The NETWORK  
/
CONTROL card  
includes one TERM connector for a local  
Console; one 10/100 NET connector for a  
TCP/IP network interface, and four  
CHANNEL EXTENDER ports. The  
Channel Extender ports are connected by  
RJ45 cables to one to four CHANNEL  
EXTENDER cards, which are an  
extension of the NETWORK card's  
operation.  
The NETWORK / CONTROL card  
supports up to sixteen simultaneous user  
telnet connections and one administrator connection to the same IP address. The network card  
must be connected to a network that uses TCP/IP.  
15.00.038  
- 19 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
3.3.2 CHANNEL EXTENDER Cards  
CHANNEL EXTENDER cards are used to extend the NETWORK functionality of the  
NETWORK / CONTROL card, providing network access to the DEVICE ports in the system.  
The Channel Extenders provide additional circuits allowing more simultaneous network  
sessions, up to the system capacity of 16 device sessions. Channel Extenders are installed in  
slots B, C, D, and slot E, replacing the NETWORK cards and the TERMINAL cards in a 3200  
system.  
The SCS3230 is normally configured with four CHANNEL EXTENDERS, but may have any  
combination of CHANNEL EXTENDER cards and TERMINAL cards, as required for your  
application.  
Note:At least one Channel Extender card is required if any DEVICE access is required using  
your IP Network.  
CHANNEL EXTENDER cards connect to the NETWORK / CONTROL card using a short RJ45  
cable. Each CHANNEL EXTENDER provides up to four (4) simultaneous sessions for DEVICE  
port access over the IP Network connection.  
3.3.3 TERMINAL Cards  
The TERMINAL card provides a point of connection for a conventional RS-232 terminal or a  
computer running a terminal emulation program. Users connected through a TERMINAL card  
may connect to any of the device cards in the system, provided that their user profile has  
access rights for the port. There are four ports per terminal card. Each port‘s parameters are set  
up independently from the other ports. All parameters are set up through the system  
administrator port. There is no access to the administration functions through the terminal card.  
The SCS3230 may have up to 3 Terminal cards, depending on system requirements. In some  
applications, the existing Terminal Card may be required for local serial connection to one of the  
Device Ports. The existing Terminal Card is compatible and may be used, however the use of  
each Terminal Card(s) reduces the number of simultaneous Network connections (by 4  
sessions) that may be made over the new 10/100 Network port on the Network Control Card.  
The 3200 Terminal cards offer configurable port parameters (baud rate, DTE/DCE, etc.), unlike  
the fixed parameters of the TERM (Console) port on the NETWORK / CONTROL card.  
The SCS3230 requires version 4.00 (or higher) of the Terminal Card binary firmware (fterm.bin).  
This is not specific to 3230, and has been available for some time. Firmware updates are  
downloadable from the Lightwave FTP site (ftp://ftp.lightwavecom.com).  
3.3.4 3200 Network Cards  
The earlier 3200 Network card (10baseT) is not supported by the 3230 Network / Control Card.  
It will not function if installed.  
Rev. A  
- 20 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
3.3.5 3200 10/100 Network Cards  
The earlier 3200 10/100 Network card is not supported by the 3230 Network / Control Card.  
It will not function if installed.  
3.3.6 Modem Card  
The Modem Card is used primarily in the Console Server 3200 systems, however, it does not  
provide or support any of the "secure" features of the SCS3230 system. It is not secure in the  
sense that the modem circuitry is not subject to the encryption used for secure SSH  
transactions, a primary reason for updating to the SCS3230. For this reason, the use of the  
modem may be limited, or the modem may simply be disabled or removed, depending on your  
site's application.  
The modem card allows non-secure dial-in access to the SCS3230 and the servers attached to  
its device ports. The modem card supports baud rates up to 38.4 kbps, and will auto-detect the  
actual connection speed. Only one user at a time may access through the modem card, and  
only one modem card may be installed per unit. The system administration functions may not  
be accessed from the modem card.  
15.00.038  
- 21 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
4: Installation Instructions  
Two options for your installation exist:  
·
·
you are either UPGRADING a CS3200 system to be an SCS3230 system, or  
you are installing a NEW SCS3230 system.  
For simplicity, we will refer to a ConsoleServer 3200 system with the NETWORK/CONTROL  
card installed as a SCS3220 system. In either case above, you will use THIS GUIDE for  
administering the SCS3230 features and options, while referring to the ConsoleServer 3200  
manual for a majority of the hardware installation instructions.  
·
·
When you purchase a CS3200 chassis, you will get the CS3200 manual (PN 15.00.017).  
When you purchase a SCS3230 NETWORK/CONTROL card, you will get the SCS3230  
System Administrator's Guide (this manual, PN 15.00.038).  
NOTE: The majority of this System Administrator's Guide is intended for the administration and  
setup of the system, when using the SCS3230 kit. The hardware of the ConsoleServer 3200  
may have been previously installed and is being upgraded at this time, or the system may be  
installed as brand new installation.  
Many hardware installation details are discussed in the ConsoleServer 3200 System Manual.  
Not all are repeated in this manual.  
4.1 Items in a SCS3230 Kit  
The SCS3230 'kit' includes all of the cards and cables required to upgrade a CS3200 to the  
SCS3230.  
PN 500.000.0010 - 10/100 BT SECURE 3230 CARD KIT  
includes:  
- (1) 500.000.0014  
- (4) 500.000.0012  
- (4) 200.0161  
-- 10/100 BT CNTL/NTWK Card  
-- 3200 CHANNEL EXTENDER Card  
-- CAT5 Cable, 24 inch long  
This SCS3230 guide, PN 15.00.038 is included with each PN 500.000.0014 card.  
Additional adapters and cables may also be included in the shipping container if ordered.  
Orders with a large number of cables and adapters are usually shipped in separate containers.  
If you are updating a CS3200 system, you may want to save your existing database from the  
CS3200 and copy it into the SCS3230. To do so, you will use Backup to save the database,  
and then Restore to copy it into the SCS3230's memory.  
Rev. A  
- 22 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
4.2 Move Database from your CS3200 to SCS3230  
The SCS3230 is designed to work with the Backup and Restore options found in the CS3200  
product. You can transfer your database from the CS3200 to the SCS3230. To accomplish this,  
you must save the Backup the system database to a local PC, and then after upgrading the  
hardware, you can then upload the saved information.  
If you do not use Backup and Restore, you will have to re-program the system with port and  
user information.  
This section assumes some existing familiarity with the administration methods (logging in,  
using the TERM port, etc.) of the CS3200 system, much of which will be similar with the  
SCS3230 system.  
4.2.1 Backup Procedure of your CS3200 System  
Before shutting down the CS3200 System, you should backup the existing user database. This  
is a normal CS3200 operation, as described in the 3200 documentation.  
1. Log in as the sys admin on Control card port Aon the CS3200's CONTROL card.  
2. Make sure that there are no users logged in to the ConsoleServer 3200. If there are  
any, have them log out or force them off the system using the FORCELOGOUTcommand.  
3. In the communications program, begin the text file capture. Name the text file as  
something that will indicate that it is the ConsoleServer 3200 parameters backup file, not  
just a plain text file (i.e., 3200.bakand not 3200.txt).  
4. Type the command BACKUPat the sys admin>prompt and press <ENTER>. Text will  
be outputted to the screen; this text is equivalent to the binary data stored in the  
ConsoleServer 3200's non-volatile memory. Wait several minutes while the  
ConsoleServer searches memory for all non-zero records (unused records are skipped  
in the backup).  
5. After the sys admin>prompt returns, end the text file capture in the communications  
program.  
6. Open the text file with a text editor (such as Window's Notepad text editor, or StarOffice,  
etc.).  
7. Remove any text after but not including the line $BACKUP COMPLETE. DO NOT EDIT  
ANY OF THE TEXT ABOVE THIS LINE! It is not necessary to remove the text after  
$BACKUP COMPLETE, but it reduces the download time for the file during the RESTORE  
process.  
4.2.2 Restore Procedure  
After the SCS3230 system is operational, you can transfer your CS3200 database into the  
system using the RESTORE option. After your database is saved in the SCS3230 system, you  
can backup and restore the SCS3230's user database using Backup and Restore.  
1. Log in as the sys admin on TERM port on the NETWORK / CONTROL card.  
2. Make sure that there are no users logged in to the SCS3230. If any users are currently  
logged on, have them log out or force them off the system by using the FORCELOGOUT  
command.  
15.00.038  
- 23 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
3. At the sys admin> prompt, type RESTORE and press <ENTER>. The SCS3230 will  
prompt for confirmation to proceed with the parameter restore process. Type YES and  
press <ENTER> to proceed. The system will ask for a second confirmation to proceed.  
Type YES and <ENTER> to start the parameter restore process. After the second  
confirmation, there is no text echoed to the screen indicating that the restore process is  
proceeding.  
4. Using the communications program, send the text file containing the backup records to  
the SCS3230. Be sure to use text mode when transferring the file. The file download  
should not take too much time; less than a minute is typical at 38.4K baud. After the  
download is complete, the SCS3230 will re-zero all unused records. If a problem is  
encountered during the text file transfer, the SCS3230 will abort the restore process and  
return to the sys admin> prompt.  
5. Once all unused records have been re-zeroed, the SCS3230 will reboot. Allow the  
complete memory check to proceed; after it is done, log in as the sys admin at the  
LCI3200> prompt.  
6. The ConsoleServer is restored to its previous settings and is ready for use. Check that  
all user, terminal, device, and other parameters are correct and acceptable.  
4.2.3 To RESTORE from a 3200 to a 3230  
Use a terminal emulation software on a PC connected to the sysadmin port of a 3200. Ensure  
that software flow control (XON/XOFF) is turned on for the software.  
1. Implement a capture to file.  
2. type “backup”.  
3. Wait until you see “$BACKUP COMPLETE”  
4. edit the backup file and remove any information before the line which starts 0,… This is  
probably the first line. Also remove the couple of lines that say $BACKUP COMPLETE. After  
the backup there will be some extraneous information, this needs to be removed.  
Copy the file to the 3230. This can be accomplished using pscp or scp  
Log in to the 3230 and establish yourself as root.  
Cd to /lci/bin  
Step 1) Type ‘restore “file name” yes’  
“file name” is the name of the file you just copied.  
The last yes is needed if you want to be told what passwords the system is inserting for this  
user. If you do not want to see the passwords, do not type anything.  
Unless there is an issue, you will observe users being added to the system and any changes  
that take place to the user name or password. If you receive a message about record number  
being incorrect, the file is either corrupt from flow control or you have not edited out the  
extraneous information that is in the file from doing the backup.  
If the service multidrop is running you will be asked to stop it and told how to do so ‘type  
“service multidrop stop”’. Goto step 1.  
Rev. A  
- 24 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
4.2.4 LCI Update  
There are four binary (.bin) files in the /lci/bin directory of the Network/Control card that may be  
needed to update existing 3200 cards for use with the new Network/Control card's firmware:  
-
-
-
-
fterm.bin  
rterm.bin  
fdevice.bin  
rdevice.bin  
These files are stored on the Network/Control Card in the /lci/bin directory on the card. The files  
customer will use the lciupdate program to install these updates, however, they do not need to  
transfer the binary files from an external computer to the 3200 - they should just direct  
lciupdate to use the /lci/bin path.  
It is not necessary to update the Device or Terminal cards before assembling the system,  
however, before the system is put into service, the cards should be updated.  
To Update a Card or Cards  
From the 3230 bash shell, type the following.  
[If you are in the sysadmin shell on a 3230, type ‘exit’ to get to the 3230 bash shell.]  
·
·
·
·
Establish yourself as super user  
Type ‘service multidrop stop’  
Type ‘ps –ax’ and look for any processes that contain the title multdrop.  
If any multidrop processes exist, type ‘killall multidrop’. Type ps-ax and again look for  
any multidrop processes. If there are any, type ‘kill –9 “the number in the farthest left  
column on the same line as the process”’, do this for all multidrop processes.  
Type lsmod and look for mdser. If mdser is not present type insmod mdser.  
If you wish to change the card binary file (*.bin) stored on the SCS3230, copy the update  
file (filename.bin) to the 3230 and place in the “/lci/bin” directory.  
Type ‘/lci/bin/lci_update “[card letter][processor number]” file’. Where file is the name of  
the file you for the slot you are updating. For instance you would probably type  
/lci/bin/lci_update b1 fterm.bin for terminal cards (the file name may be different and b  
could be b,c,d,e)  
·
·
·
·
·
·
/lci/bin/lci_update h1 fdevice.bin for device cards (the file name may be different and h  
could be h,I,j,k,l,m,n,o)  
The processor number is relevant to multiprocessor cards. You will be informed if it is  
anything other than one.  
15.00.038  
- 25 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
4.3 Connecting to the TERM Port  
The cable kit P/N 200.0135 contains the necessary adapters to interface the system TERMport  
on the NETWORK / CONTROL card to a laptop or a terminal. Using the adapters in the kit,  
follow the steps outlined below.  
The communications settings for the system administrator port (TERM) are fixed at 9600 baud,  
one stop bit, no parity, eight data bits, and DCE (9600 8N1 DCE).  
NOTE: The administration functions may also be reached via telnet. However, it is first  
necessary to configure the network ports through the direct serial connection.  
1.  
Turn on power to the terminal or computer. If using a computer, start the desired  
communication program. The terminal or communications program used must  
be in VT100 emulation mode. Note that the VT100 functions keys are not always  
mapped to the terminal or computer function keys; consult the appropriate  
documentation for further information.  
2.  
3.  
Ensure that the communications settings of your Terminal are correct.  
Locate the serial port on the terminal or computer and determine what type of  
connector is used. The cable kit included with theSCS3230 contains each of the  
following: one RJ45 serial cable, an RJ45 to male DB9 adapter, an RJ45 to  
female DB9 adapter, an RJ45 to male DB25 adapter, and an RJ45 to female  
DB25 adapter. Select the appropriate adapter for the serial port on the terminal  
or computer.  
4.  
5.  
Firmly seat the adapter in the serial port. Screw down the adapter to secure it to  
the serial port.  
Insert one end of the serial cable into the adapter until a click is heard. Insert the  
other end of the serial cable into TERM port of the NETWORK / CONTROL card,  
again until a click is heard.  
6.  
7.  
Press <ENTER>on the keyboard. Thelogin> (using Telnet) or login as: >  
(using SSH) prompt should appear. If not, check that the SCS3230 is connected  
to the appropriate power outlet, the power switch is on, the cards are firmly  
seated, and that all cable connections are secure. If "garbage" characters  
appear on the screen, check that the communications settings are correct.  
The system administrator may now login to the system.  
Rev. A  
- 26 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
5: Connecting Equipment to the SCS3230  
When connecting devices to the SCS3230, be sure to use Lightwave Communications  
cables and adapters to ensure the proper transmission of data signals. If a device has  
an RJ45 serial port, use the manufacturer's cable included with the equipment to  
convert the RJ45 serial connector to a DB9 or DB25 connector, and then use a  
Lightwave Communications adapter to convert back to RJ45 to attach to the device  
port. Directly connecting the RJ45 port on the SCS3230 to the RJ45 port on a third-  
party device may not allow for the proper transmission of data signals.  
SCS3230 serial port default settings  
Port Type  
TERM  
Terminal  
Baud Rate  
9600 (fixed)  
38400  
Data Bits  
Parity  
None  
None  
None  
Stop Bits  
Port Configuration  
8
8
8
1
1
1
DCE  
DCE  
DCE  
Device  
9600  
5.1 Terminal Card  
Terminal Card typical adapters and port configuration:  
System Type  
Wyse 50 / 60  
DEC VT330, PC (25pin)  
PC (9pin)  
Adapter Part Number  
200.0066  
200.0067  
Port Configuration  
DCE  
DCE  
DCE  
200.0070  
Materials:  
·
·
·
·
SCS3230 terminal port  
terminal or computer with RS-232 serial port  
RJ45-terminated Cat 5 cable (standard LAN cable)  
Lightwave adapter for terminal serial port  
1.  
Attach the Lightwave adapter to the terminal or computer serial port.  
2.  
Connect the Cat 5 cable to the adapter. Connect the other end to theSCS3230  
terminal port.  
3.  
Turn on the terminal or start the computer’s communication program. Make sure that  
the communication parameters of the terminal or computer match those of the terminal  
port.  
15.00.038  
- 27 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
5.2 NETWORK / CONTROL Card  
The network port of the NETWORK / CONTROL card runs at 10/100 Mbits, half-duplex,  
with auto-negotiation. The device used to connect the ConsoleServer to the network  
(i.e., a hub or switch) must support this configuration.  
Materials:  
·
·
·
SCS3230 network port  
network point-of-connection (i.e., a switch or hub)  
RJ45-terminated Cat 5 cable (standard LAN cable)  
1.  
2.  
Configure the ConsoleServer network parameters to the desired values as  
outlined in section 6.5.  
Configure the network point-of-connection. It must be manually set to 10 Mbits, half-  
duplex, with no auto-negotiation.  
3.  
4.  
Connect the ConsoleServer network port to the network using a standard LAN cable.  
Check the status lights at the network end of the connection. It should indicate a good  
link. Try reaching the IP address assigned to the ConsoleServer by using PINGor  
TELNET. If there is a problem, check the network configuration on both ends.  
5.3 Modem Card  
Materials:  
·
·
·
SCS3230 modem port  
Analog telephone line (POTS)  
RJ11 modular telephone cable  
1.  
2.  
3.  
Locate the modular jack for the telephone line to be used. Select a telephone  
cable with sufficient length to reach between the jack and the ConsoleServer.  
Connect one end of the telephone cable to the jack. Connect the other end to  
the ConsoleServer modem port.  
Make sure the ConsoleServer is powered. Dial the telephone number of the line  
connected to the ConsoleServer. The modem should automatically answer. If  
not, check the telephone line and connections.  
Rev. A  
- 28 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
5.4 Device Card  
NOTE: DEVICE Cards MUST be updated to Version 4.03 (or higher) firmware for SCS3230  
The SCS3230 is designed so that the default device port communications settings will match  
the communications settings of most Sun® server and workstation console ports (9600 baud, 8  
data bits, no parity, one stop bit). Other equipment types (i.e., Cisco®) frequently use similar  
communications settings; check the manuals included with the equipment for the correct  
settings. The table below lists the default serial port communications settings for the SCS3230.  
Sections 6.3 and 6.4 outline the commands for changing the terminal and device port  
communications settings.  
The following tables list the adapter part number and port configuration for some common  
equipment types that may be connected to the SCS3230. Note that in some cases, an  
additional cable or adapter is included with the equipment to convert a proprietary pinout to an  
EIA-standard pinout. Also, note that it is not possible to connect the RJ45 serial port of the  
ConsoleServer directly to the RJ45 serial port of any third-party equipment. Sun Netra  
servers, Cisco switches, and other similar devices require a special adapter or cable to connect  
to the ConsoleServer. The adapter or cable is usually provided by the manufacturer of the  
equipment (e.g., Sun), or may need to be created by the user. The adapters and cables from  
the equipment manufacturer are usually designed to interface directly to a terminal, so the  
ConsoleServer device port must be configured as DTE rather than its default value of DCE.  
Lightwave Communications has pre-made adapters and kits for some common equipment  
types; contact Lightwave for information regarding your specific application.  
Note:Some adapters are also available in quantity packs, and may be shipped under a different  
part number. Quantity packs are "299.xxxx" compared to "200.xxxx".  
Device Card typical adapters and 3200 port configuration:  
System Type  
SUN  
HP, SGI, PC (9pin)  
PC (25pin)  
Sun Netra t1/Cisco  
Adapter Part Number  
200.0066  
200.0070  
200.0067  
200.0225  
Port Configuration  
DCE  
DCE  
DCE  
DCE  
RJ45 to RJ45 Cables:  
Part Number  
200.0062  
200.0063  
200.0064  
200.0065  
Length  
2m  
5m  
10m  
15m  
15.00.038  
- 29 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
Standard DB9 or DB25 installation:  
Materials:  
·
·
·
·
SCS3230 device port  
device with RS-232-C serial console port  
RJ45-terminated Cat 5 cable (standard LAN cable)  
Lightwave adapter for serial console port  
1.  
2.  
Attach the Lightwave adapter to the serial console port.  
Connect the Cat 5 cable to the adapter. Connect the other end to the SCS3230 device  
port.  
3.  
Check that the device port and serial console port communications parameters match,  
and synchronize them if they do not match.  
Sun® Netra t1 installation:  
Materials:  
1.  
2.  
3.  
Connect a Cat 5 cable to the console port of the Netra. Connect the other end to the  
end of the ConsoleServer/Netra adapter (P/N 200.0225) marked “to Netra”.  
Connect another Cat 5 cable between the adapter end marked “ConsoleServer” and the  
ConsoleServer device port.  
Check that the device port and serial console port communications parameters match,  
and synchronize them if they do not match.  
Rev. A  
- 30 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
0 0 2 3 r e v r e S e l o s n o C  
15.00.038  
- 31 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
$
%
&
'
1HWZRUN6ORWV  
%& '  
(
NETWORK/  
CONTROL  
MODEM CHANNEL CHANNEL CHANNEL T ERMINAL SWITCH SWITCH DEVI CE DE VICE DEVICE DEVI CE DE VICE DEVI CE DEV ICE DE VICE  
EXTENDER EXTENDER EXTENDER  
T
E
R
M
A
B
C
D
A
B
C
D
A
B
A
B
C
D
A
B
C
D
A
B
A
B
C
D
A
B
C
D
A
B
C
H
A
N
N
E
L
E
X
T
E
N
D
E
R
C
D
C
D
C
D
S
N
E
T
10/100  
Caution! Replace with same type and rating fuse.  
100-240V ~, 1A, 50/60 Hz  
(
'
&
%
T
4A, 250 VAC  
Fig. 3 General layout showing DEVICE port numbering.  
Rev. A  
- 32 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
6: SCS3230 Setup Script and  
System Administration  
The SCS3230 uses a script file to assist in the initial setup and configuration of the 3230  
system. The script is intended for the first time the unit is turned on, in order to get the system  
'up and running' as quickly as possible.  
Note:In some of the following screens, the term "3220" may be found in place of the "3230"  
which is found in the actual screens of the SCS3230 system.  
The following section outlines the administration functions and commands.  
The administration functions and commands are designed to enable the administrator to  
configure the SCS3230 to fit the needs of the system application. User IDs, devices, terminals  
and access rights may be configured using the administration commands.  
Many commands may be abbreviated to one extent or another, but some may not be  
abbreviated at all. For example, the command VERSIONmay be abbreviated to VER, but  
LCIUPDATEmay not be abbreviated. See Appendix E for more information regarding  
abbreviations.  
15.00.038  
- 33 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
NOTE: <ESC> <ESC>or <CTRL>+Cwill cancel an operation and return to the administrator  
prompt. Pressing <CTRL>+Rat the LCI3200>or sys admin>prompt will discard the  
characters on the current command line, and retype the last command used; <ENTER>must still  
be pressed to execute the command. Pressing <CTRL>+Uat either prompt erases the current  
command line back to the prompt.  
6.1 Power-up Sequence and  
Basic Use of the Administrator Functions  
NOTE: When the system is first turned on, it may take as long as 90 seconds before the front  
panel display will show any activity, and before the system will 'wake up'. Total boot-up time is  
generally about 3 minutes.  
When the SCS3230 is first installed and powered up, it must be configured through the serial  
terminal port. Connect the terminal port to a terminal device or computer using a terminal  
emulation program. After the network interface has been configured, the administration login  
may also be reached via telnet. All the functions available from a local serial connection (with  
the exception of BACKUPand RESTORE) are also available through telnet by connecting to port  
5000 of a ConsoleServer’s network IP address.  
The serial terminal will display the following text at power-up:  
ConsoleServer3200 Boot V1.76  
Copyright 2000 by Lightwave Communications, Inc. All rights reserved.  
Identify Flash  
Flash ID OK  
Verifying Flash Image  
Starting system  
Lightwave Communications, Inc. ConsoleServer3200  
Please wait...system initializing  
Checking non-volatile memory...  
2048  
Start checking and reading stored data  
Reading User Start up .........  
LCI3200>>  
The power-on self-test may be skipped by pressing<ESC> <ESC>or <CTRL>+C, but  
the SCS3230 should be allowed to complete the POST if possible (this check usually  
takes about three minutes). This information is not available on a network connection,  
as it is not possible to connect to the ConsoleServer via telnet until the power-on self-  
test is complete. At the completion of the power-up sequence, the administrator is  
logged out, as indicated by theLCI3200>>prompt. Some commands may be used  
from this prompt, but most are available only when logged in.  
NOTE: The administrator may define the system prompt using the PROMPTcommand (see  
section 6.11), but the system default prompt (LCI3200>>) is used in this guide for clarity.  
Rev. A  
- 34 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
6.1.1 Logging In, Serial Connection  
LCI3200>>login  
Please enter password: ****  
sys admin>>  
To log in on the ConsoleServer through a local serial connection, type LOGINat the  
LCI3200>>prompt. The system returns the prompt Please enter password:. The  
default administrator password isPASS. The ConsoleServer will only echo stars when the  
password is entered. If the password is correct, the prompt will change to sys admin>>.  
6.1.2 Logging In, Network Connection  
UNIX_MACHINE# telnet 172.16.1.200 5000  
Connecting to 172.16.1.200 port 5000...  
Escape sequence is ^]  
Welcome to the ConsoleServer3200 SysAdmin  
LCI3200>>login  
Please enter password: ****  
sys admin>>  
To log in on the ConsoleServer through a network connection, the network interface for the  
ConsoleServer first must be configured through the serial terminal. Once the network interface  
is configured and functioning, telnet to port 5000 of the IP address assigned to the  
ConsoleServer. The ConsoleServer will display a welcome message and the LCI3200>>  
prompt. At the prompt, type LOGIN. The system will only prompt for the password. At the  
Please enter password:prompt, enter the administration password. The default  
administrator password isPASS.  
If the password is correct, the prompt will change to sys admin>>.  
15.00.038  
- 35 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
6.1.3 Logging Out  
To log out from an administration session, enter the command LOGOUTor LOGOFF. If logging  
out from a network session, the ConsoleServer will disconnect the telnet session. If logging out  
from a direct serial session, the ConsoleServer will return to the LCI3200>>prompt.  
Rev. A  
- 36 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
6.1.4 System Help (Command List)  
To access the help screens, type <F1> H, ?, or HELPto display the help page, once logged in.  
The HELP screens offer a Sys Admin Command List.  
HELP SCREEN  
sys admin>>?  
ConsoleServer 3230 Sys Admin Command List  
[] - optional <> - parameter must be specified | - OR  
abbreviations  
- Display list of command abbreviations  
- Add a new user  
- Break connection  
- Display list of current connections  
(/MONITOR will auto-refresh)  
- Delete a user by user id or number  
- Display device settings  
adduser [new user id]  
break <terminal channel>  
connections [/monitor]  
deleteuser [user id|/n]  
devices  
devices [n|device name] - Change settings (n can be 1 to 32)  
edituser [user id] - Edit a user's settings  
forcelogout <terminal channel> - Force a user off the system  
forcelogout sysadmin  
info <slot letter>  
linesperpage [n]  
- Logout sys admin on a network connection  
- Report miscellaneous information  
- Display/set number of lines before pause  
(n can be 0 to 99, 0 disables)  
- Display list of installed cards  
- Display list of device names  
- Display list of users  
- Exit sysadmin shell  
- Display/set modem init string  
/DEFAULT will set init string to default  
listcards  
listdevices  
listusers [user id|/all]  
exit  
modem [/default]  
Press <CR> to continue  
modemtimeout [t]  
- Display/set timeout for modem calls  
(t can be 0 to 30 minutes, 0 disables)  
- Display status of power supplies  
- Set/clear system prompt for logged-out state  
or set prompt to factory default  
powerstatus  
prompt [/clear|/default]  
telnettimeout [t]  
- Display/set timeout for telnet sessions  
(t can be 0 to 30 minutes, 0 disables)  
- Display terminal settings  
- Change settings (n can be 1 to 17)  
- Display/set timeout on sys admin login  
(t can be 0 to 30 minutes, 0 disables)  
- Report software version information  
(/ALL will return versions for all cards)  
terminals  
terminals [n]  
timeout [t]  
version [/all|slot letter]  
sys admin>>  
15.00.038  
- 37 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
6.1.5 Abbreviations  
A listing of abbreviations for the administrator commands is also available when  
connected to the administrator port.  
sys admin>>abbreviations  
ConsoleServer 3230 Sys Admin Command Abreviations List  
abbreviations  
adduser  
- a  
- addu  
au  
- (no abbreviation)  
- c  
- deleteu  
- dev  
- editu  
break  
connections  
deleteuser  
devices  
edituser  
eu  
- (no abbreviation)  
- h, ?  
- (no abbreviation)  
forcelogout  
help  
info  
linesperpage  
- linespp  
lines  
lpp  
listcards  
listdevices  
listusers  
- listc  
lc  
- listd  
ld  
- listu  
lu  
Press <CR> to continue  
exit  
modem  
modemtimeout  
- (no abbreviation)  
- (no abbreviation)  
- modemt  
mt  
- po  
powerstatus  
ps  
- pr  
- telnett  
tt  
prompt  
telnettimeout  
terminals  
timeout  
version  
- term  
- time  
- ver  
sys admin>>  
You must use the <CR> to go to the second page of the Abbreviations list. You cannot interrupt  
it in the middle, only let it play out. THEN, you return to sys admin>.  
sysadmin@SCS3230 /tmp$ h  
Command  
--------  
User  
----  
Description  
-----------  
SAVE  
root  
root  
root  
root  
root  
root  
root  
sysadmin/root  
root  
root  
Save changes in RAM to Flash  
changes  
lciupdate  
poweroff  
reboot  
restore  
setup  
sysadmin  
timeout  
unsaved  
List changed files from factory settings  
Download flash updates to terminal or device cards  
Power off the SCS3230  
Reboot the SCS3230  
Restore pararmeters from a previous save  
Run the System Configuration script  
Run the Sys Admin shell  
Display/set timeouts for console or telnet logins  
List files changed since last SAVE  
sysadmin@SCS3230 /tmp$ sysadmin  
sys admin>>  
Rev. A  
- 38 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
6.2 Sys Admin vs. root access  
The System Administrator (sys admin) has the ability to run the sysadmin functions of the  
system. In order to run the Setup command, the System Administrator must change to the root  
user. Below is a list of commands accessible by the different admin levels:  
The Sys Admin must sign on, and then switch to root level (requires root password) so that they  
may run the Setup command. The default root password is 'root'. This root password should be  
changed as soon as the System Administrator has gained access to the system.  
To Change the root-level password of the SCS3230, follow the steps below.  
1. Log in as sysadmin(you see the bash prompt) = sysadmin@SCS3230 /tmp$  
2. suto root level; you must enter the existing root password (default = root)  
3. After password is accepted, notice root level = root@SCS3230 /var/tmp#  
4. Use passwdto change root level password  
5. After successful, 'authentication tokens updated' message is displayed. You are  
returned to the root level prompt = root@SCS3230 /var/tmp#  
6. Use exitto leave root level (sysadmin@SCS3230 /tmp$)  
7. Use logoutto log out of the system  
If you lose the root password, there is no 'back door' password or higher-level access. The  
Flash memory device would have to be replaced in order to regain access to the system. Your  
existing data on that Flash device would be inacessible.  
Only the root level password has access to the SAVE feature which can invoke permanent  
changes to the system's memory and features. Turn the system power off without using SAVE  
will cause any system changes to be lost.  
15.00.038  
- 39 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
6.3 Setup Script  
The System Administrator must switch to root level in order to access the Setup Script.  
From the root command prompt, type setupto begin the setup script:  
Follow the script prompts; use the arrows or 'Enter' to advance unless otherwise indicated.  
Rev. A  
- 40 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
Using the arrow keys, you may select from any of the following attributed to administer. The  
script also provides 'hints' along the way. You may also 'exit' using the Done command. Using  
the 'enter' key to advance, you will step through a majority of the Setup script.  
6.3.1 Hostname and IP Address  
Use the arrow keys to advance; or in some cases, simply press 'enter'.  
The existing HOSTNAME information is displayed in the 'Answer' field.  
15.00.038  
- 41 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
Type in your HOSTNAME information in the Answer field. It may be up to 24 characters long; it i  
After entering your Hostname, the system advances to the IP Address setting.  
Enter your IP information, in dot-quad format. Select Next to proceed.  
Rev. A  
- 42 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
Next, enter your Network Mask information, in dot-quad format. Select Next to proceed.  
Then, enter your gateway information. Select Next to proceed.  
15.00.038  
- 43 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
You are then returned to the Script's menu. You may continue the script by pressing 'enter' to  
advance, or select another option.  
6.3.2 Timezone (Clock)  
You must select a Timezone value for the SCS3230's clock. The SCS3230 uses the universal  
time system  
Rev. A  
- 44 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
Using the up and down arrows, select an appropriate Time Zone parameter. To go up one level  
in the Time Zone menu, move to the ".." prompt at the top of the list. Press 'enter' to select  
your value.  
Once completing the Timezone field, you are returned to the Script's menu.  
15.00.038  
- 45 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
6.3.3 Configure DNS  
Select 'Next' to advance in the DNS (Directory Name Server) menu.  
Rev. A  
- 46 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
Fill in the IP address information for your Primary Nameserver.  
Note: If you start to fill in this parameter, but cannot complete the value at this time, you must  
enter some dot-quad address in order to leave this prompt. A value of '10.0.0.1' may be suitable  
in this instance.  
Enter your Secondary Nameserver information, if appplicable. Press Next to advance.  
15.00.038  
- 47 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
Enter your Tertiary Nameserver information, if applicable.  
Press Next to advance to the configuration for Hosts.  
6.3.4 Hosts  
The parameters for HOSTS is a bit different than other screens. Here, you will edit the data.  
Rev. A  
- 48 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
The system has started an 'edit' routine which you must 'exit' by using the ESC key to end the  
edit mode, and get to the 'Next' prompt  
You are then returned to the Script menu.  
6.3.5 Services  
You can now enable or disable several Services of the SCS3230.  
15.00.038  
- 49 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
Choose Yes or No, by using your arrow keys. Press Next to advance.  
6.3.6 Syslog  
Rev. A  
- 50 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
6.3.7 SSH Logins  
SSH is the secure, and preferred method of accessing the system.  
15.00.038  
- 51 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
6.3.8 TELNET logins  
6.3.9 NTP Daemon  
You can enable or disable the NTP Daemon, if desired.  
After setting the NTP Daemon, you are returned to the Script's Menu.  
Rev. A  
- 52 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
6.3.10  
Configure the Firewall  
You can configure the firewall, for security in your system.  
Press Next to advance.  
15.00.038  
- 53 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
Enable the Firewall to see additional prompts. Choose No to end this step.  
Rev. A  
- 54 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
6.3.11  
Firewall Reject Method  
You can choose to Deny (ignore) connection attempts, or send back a 'Rejected' message.  
6.3.12  
Ping Attempts  
15.00.038  
- 55 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
After finishing the 'Invisible to Ping' prompt, you will be returned to the Script Menu. There are  
no more script options to do. You may go back and re-do any prompts you wish, if necessary.  
Rev. A  
- 56 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
6.3.13  
Confirm Changes  
Selecting YES will 'commit' the changes to the System.  
15.00.038  
- 57 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
The System will run through the system configuration and make the appropriate changes. Note  
that some commands may show a 'fail' which may be normal for that instance. A 'fail' message  
may mean that a command was not previously running, and so the command to kill that  
application 'failed' (because it wasn't running). However, if you review the operations at a later  
time, you will probably see an 'OK' message for the same prompts and options.  
THE VERY FIRST TIME the System is run, the Setup script will automatically undergo a reset  
and reboot to save the features to the system.  
6.3.14  
SAVE Command  
Every other operation of the Setup script file, the root-level system administrator will have to  
execute the SAVE COMMAND in order to preserve the changed values.  
Rev. A  
- 58 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
7: Creating and Managing Users  
7.1 Adding a User ID  
The ADDUSERcommand creates user IDs and assigns initial privileges. The following  
screen will be displayed when the command is used:  
sys admin>>ADDUSER  
Number of available user records: 200  
Number of users defined: 0  
Enter user id | USER ID >  
Press <ENTER>after typing the user ID. The user name is not case-sensitive. The next prompt  
asks for a password for the user ID. When the user logs in for the first time he will be asked for  
this password. This password is case-sensitive and is pre-expired. The user must change the  
password before accessing any of the SCS3230 device ports. The user password may be up to  
10 alphanumeric characters long, and may not contain the “*” character. The SCS3230 will  
echo only stars when the sys admin enters the password and confirmation  
Enter case sensitive password | PASSWORD > ****  
Re-enter case sensitive password | PASSWORD > ****  
0-17 | MAX CONCURRENT LOGINS: 1>17  
This parameter limits the number of simultaneous logins a user may have. The sys  
admin may select between 0 and 17 concurrent logins. A user with 0 logins will have  
connect and listen permissions defined, but cannot login to access anything until a  
number of logins greater than 0 is defined.  
Allowed devices example: 1-5,10 | DEVICES 0 > 1,5,7,8,30  
Allowed listen devices example: 1-5,10 | DEVICES 0 > 1-32  
The sys admin is now prompted to define the device ports that the user will be allowed  
to access for direct connections and listening connections. If more than one port is to  
be allowed, then the individual ports must be separated by a comma. A range of ports  
may be specified using the dash (“-“).  
15.00.038  
- 59 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE DEVICE  
25  
A
21  
A
29  
A
1
A
5
A
9
A
13 17  
A
A
26  
B
22  
B
30  
B
2
B
6 10 14 18  
B
B
B
B
27  
C
23  
C
31  
C
3
C
7
C
11 15 19  
C
C
C
28  
D
24  
D
32  
D
4
D
8 12 16 20  
D
D
D
D
Allowed devicesdetermines which devices a user may select for direct access.  
Allowed listen devicesdetermines which devices a user may use listen access.  
“Listening” is defined as being able to read from an existing device port connection  
without write ability. This feature is useful for sharing information among multiple users  
or for monitoring a user’s session with an attached device.  
Fig. 4 Device Port Numbering  
HELPFUL HINT: Make a diagram or spreadsheet of connections indicating connections  
between devices and theSCS3230 device ports as numbered above.  
The Allow user to clear device buffer (Y/N) | YES >option determines  
whether a user may use the CLEARcommand to delete all the data stored in a device  
port FIFO buffer. The sys admin may want to inhibit this ability to preserve user  
accountability when accessing attached devices. Users are allowed to clear buffers by  
default. Pressing <ENTER>will allow the user to clear the buffer; typingNOand then  
pressing <ENTER>at the prompt when defining a user ID will disallow the user from  
clearing all device buffers.  
The Clear screen after a command (Y/N) | YES >option determines if the  
screen clears when most commands are executed. Disallowing this screen behavior  
keeps the last few commands and responses on the terminal screen. The default value  
for this option is YES. Pressing <ENTER>will accept the default value; typing NOand  
then pressing <ENTER>disallows this screen behavior.  
Rev. A  
- 60 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
sys admin>>ADDUSER  
Number of available user records: 200  
Number of users defined: 0  
Enter user id | USER ID > tom  
Enter case sensitive password | PASSWORD > ****  
Re-enter case sensitive password | PASSWORD > ****  
0-17 | MAX CONCURRENT LOGINS: 1> 2  
Allowed devices example: 1-5,10 | DEVICES 0 > 1-4  
Allowed listen devices example: 1-5,10 | DEVICES 0 > 0  
Allow user to clear device buffer (Y/N) | YES > n  
Clear screen after a command (Y/N) | YES > n  
Enter user id | USER ID >  
Sys admin>>  
The above procedure has defined one user. TheSCS3230 will prompt for the next user  
ID to be defined. Repeat the set-up process until all users have been entered. To  
return to the sys admin prompt, simply press <ENTER>at theUSER ID>prompt. More  
users may be added at any time by using the ADDUSERcommand. A maximum of 200  
users may be defined.  
7.2 Editing a User ID  
sys admin>>EDITUSER TOM  
Enter accepts present value  
Enter case sensitive password | PASSWORD >  
0-17 | MAX CONCURRENT LOGINS: 2>6  
Allowed devices example: 1-5,10 | DEVICES 1-4 >  
Allowed listen devices example: 1-5,10 | DEVICES 0 >  
Allow user to clear device buffer (Y/N) | YES > n  
Clear screen after a command (Y/N) | NO > n  
sys admin>>  
To edit or change parameters for a particular user after defining that user ID, use the  
EDITUSERcommand. For example, if the user 'Tom' needed to have more concurrent  
login capabilities, the sys admin would typeEDITUSER TOMon the command line. As  
each line comes up, change the settings and press <ENTER>, or press <ENTER>to  
accept the current setting.  
NOTE: When editing any group of parameters, pressing the <ENTER>key will accept  
the current value and move to the next parameter in the list.  
7.3 Listing User IDs  
To list the users that have been defined, use the LISTUSERS command. When used  
alone, the command will display all user ID’s. When a user ID is specified after the  
command, the parameters for that user ID will be displayed. If the/ALLqualifier is  
15.00.038  
- 61 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
included after the LISTUSERScommand, then the parameters for all users are  
displayed.  
sys admin>>LISTUSERS  
1: User id > PETE  
2: User id > KEVIN  
3: User id > TONY  
sys admin>>LISTUSERS /ALL  
1: User id > PETE  
Allowed devices > 1-32  
Allowed listen devices > 1-32  
Max logins > 17  
Allow user to clear device buffer > YES  
Clear screen after a command > YES  
2: User id > KEVIN  
Allowed devices > 1-32  
Allowed listen devices > 1-32  
Max logins > 17  
Allow user to clear device buffer > YES  
Clear screen after a command > YES  
3: User id > TONY  
Allowed devices > 1-32  
Allowed devices > 1-32  
Max logins > 17  
Allow user to clear device buffer > YES  
Clear screen after a command > YES  
sys admin>>  
Rev. A  
- 62 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
7.4 Deleting a User ID  
To delete a user, use theDELETEUSERcommand, followed by the user ID on the same  
line. The LISTUSERScommand will allow verification after deleting a user ID. The  
following command sequence is an example of the use of DELETEUSERwith  
LISTUSERS:  
sys admin>>DELETEUSER PETE  
Delete user:pete  
Yes or No (N):y  
sys admin>>listusers  
2: User id > KEVIN  
3: User id > TONY  
sys admin>>  
User IDs may also be deleted by their record number. As each user ID is created, it is assigned  
a sequential record number. This number is associated with the user ID and will be displayed  
using the LISTUSERcommand.  
sys admin>> deleteuser /3  
Delete user:tony  
Yes or No (N):y  
sys admin>>  
To delete a user ID using the record number, specify the number as a qualifier after the  
DELETEUSERcommand in the form DELETEUSER /N, where Nis the user record number.  
7.5 Devices Command  
Device port parameters must be defined by the sys admin using the DEVICES  
command. If a single device port is to be changed, the port number must follow the  
DEVICEScommand. If the DEVICEScommand is entered by itself, the configuration of  
all device ports will be listed. To edit all possible device ports for a unit, enter the  
command DEVICES /ALL.  
Programmable elements include: device name, baud rate, stop bits, parity, data bits,  
DCE/DTE, flow control and inhibit direct mode. Pressing<ENTER>accepts the  
parameter as is. If changes need to be made, each parameter may be edited as it  
comes up after each >prompt.  
The device name may not contain the *character. If a name is entered with this  
character, the administrator will be asked to re-enter the name.  
15.00.038  
- 63 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
Four baud rates are offered: 9600, 19200, 38400, and 57600. Most devices use 9600  
as the console/admin port baud rate, so the device port defaults to this value. Check  
the equipment documentation for the proper baud rate.  
The format of the bit-wise transmission of data is determined by the stop bits, parity,  
and data bits parameters. The default settings are 1 stop bit, no parity, and 8 data bits.  
Check the equipment documentation for the proper settings.  
Each device port may be separately configured as either DCE or DTE. The DCE setting  
is used when connecting to a DTE device such as a computer. The DTE setting is used  
when connecting to a DCE device such as a managed switch. The device ports are  
configured as DCE by default.  
The device port flow control settingdetermines the method of flow control. The two  
most common settings are XON/XOFF (a.k.a. software) and RTS/CTS (a.k.a.  
hardware). DTR/DSR is used very infrequently. The default setting for the device ports  
is XON/XOFF. Check the equipment documentation for the correct flow control setting.  
The INHIBIT DIRECT MODEsetting allows the administrator to turn off port buffering  
while a user is connected to the device and is in direct mode. The device port buffer still  
collects data while not in direct mode when this setting is active. It may be desirable to  
disable direct mode buffering so sensitive data is not viewable by other users, but alert  
and panic messages from the attached device are still stored when nobody is  
connected. This setting is disabled by default, so buffer data is collected both in and out  
of direct mode.  
sys admin>>terminal 1  
Enter accepts present value  
T1: 0=9600, 1=19200, 2=38400, 3=57600 | BAUD RATE: 9600>  
T1: 0=1, 1=2  
T1: 0=None, 1=Odd, 2=Even  
| STOP BITS: 1>  
| PARITY: None>  
T1: 0=8, 1=7, 2=6  
T1: 0=DCE, 1=DTE  
T1: 0=XON/OFF, 2=RTS/CTS  
Card installed, settings updated  
| DATA BITS: 8>  
| EQUIP PORT TYPE: DCE>  
| FLOW CONTROL: XON/XOFF>  
sys admin>>  
A list of device port names and their corresponding port number may be displayed by  
using the LISTDEVICEScommand.  
Rev. A  
- 64 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
7.6 Terminals Command  
The sys admin defines terminal port parameters using theTERMINALScommand in a  
manner similar to the DEVICEScommand. If the command is entered by itself, the  
terminal settings will display. If the terminal port number is specified after the  
command, then the settings for that terminal port may be altered. Programmable  
elements include: device name, baud rate, stop bits, parity, data bits, DCE/DTE, and  
flow control as in the example below.  
sys admin>>TERMINALS 1  
Enter accepts present value  
T1: 0=9600, 1=19200, 2=38400, 3=57600 | BAUD RATE: 38400>  
T1: 0=1, 1=2  
| STOP BITS: 1>  
| PARITY: None>  
| DATA BITS: 8>  
| EQUIP PORT TYPE: DTE>  
T1: 0=None, 1=Odd, 2=Even  
T1: 0=8, 1=7, 2=6  
T1: 0=DCE, 1=DTE  
T1: 0=XON/OFF, 1=DTR/DSR, 2=RTS/CTS | FLOW CONTROL: XON/XOFF>  
Card installed, settings updated  
sys admin>>  
Terminal port connection location reference template:  
7.7 Network Commands  
The NETWORK command setup is changed, if compared to the CS3200 system.  
The NETWORK or access ports in chassis slots B, C, D and E are connected to the  
CONTROL/NETWORK card using CHANNEL EXTENDER cards. All chassis backplane  
Network ports are accessed through the 10/100 IP network port on the CONTROL/NETWORK  
card.  
When used without qualifiers, the NETWORKcommand will display the network settings assigned  
to each card slot. The IP address, subnet mask, default gateway, secondary route, and bootp  
settings are displayed for each slot. These parameters are assigned to the slots rather than the  
cards. If a network card is moved from one slot to another, it will have the parameters assigned  
to its new slot rather than those previously assigned to it.  
When used with the /ALLqualifier, the NETWORKcommand will allow the system administrator  
to change the network parameters for all the card slots in order. The sys admin will be  
prompted to enter the IP address, subnet mask, default gateway, secondary route, and bootp  
settings for each card slot. If <ENTER>is pressed at the prompt, the value displayed in the  
prompt will be used. After entering the parameters for each slot, the sys admin will be asked if  
the new parameters should be used. If NOis entered (or just <ENTER>is pressed), then the  
previously entered changes will be discarded and the system will move on to the next slot’s  
parameters. If YESis entered, then the slot’s network parameters will update in control card  
memory and the control card will send the new parameters immediately to the card in that slot.  
15.00.038  
- 65 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
If the card is a network card, it will immediately acquire the new network parameters and  
disconnect all telnet sessions to that card. If a terminal card is in the slot, or if the slot is empty,  
the network parameter update is refused, but the network parameters for that slot will be saved  
to control card memory.  
When the NETWORKcommand is used with a card slot letter as a command qualifier, it will  
attempt to change the parameters only for that card slot. In all other aspects, the command  
behaves the same as if the /ALLqualifier was used.  
If a bootp server is present on the same network as the SCS3230 network card and bootp is  
enabled on the network card, then the network card will use the IP address and subnet mask  
assigned by the bootp server rather than those assigned by the sys admin.  
Once a network card has been assigned an IP address either by a bootp server or by the sys  
admin, then the ConsoleServer may be accessed by telnet. Connecting to the default telnet  
port reaches the user login; connecting to port 5000 reaches the sys admin login.  
7.8 Modem Command  
The MODEMcommand allows manipulation of the modem card initialization string. When the  
command is entered, the sys admin is prompted for the new initialization string. Typing a new  
initialization string and pressing <ENTER>will create a new initialization string for the modem,  
while just pressing <ENTER>will accept the current value. After pressing <ENTER>, the sys  
admin is asked to confirm the changes to send the string to the modem. Typing YESand  
<ENTER>will send the initialization string immediately to the modem card, while typing NOand  
<ENTER>discards the entered initialization string and keeps the old string. If the modem card is  
not currently installed, the settings are not sent, but are kept in control card memory. The  
control card will send those settings in memory when a modem card is installed.  
sys admin>>MODEM  
Enter accepts present value  
Init string | > ATB2H0  
Save changes and update modem card? Yes or No: No>yes  
Modem card not installed in slot A, init string saved  
Sys admin>MODEM /DEFAULT  
Current modem init string is: ATB2H0  
Set modem to factory default value of: ATH0S0=1  
(write out YES) Yes or No: No>yes  
Modem card not installed in slot A, init string saved  
sys admin>>  
The sys admin may also reset the initialization string to the default value by entering the  
command with the default qualifier in the form MODEM /DEFAULT. When using the /DEFAULT  
qualifier, the current initialization string is displayed, along with the factory default string. The  
sys admin is asked to confirm the use of the default modem string; typing YESand <ENTER>will  
send the default initialization string immediately to the modem card, while typing NOand  
<ENTER>keeps the old modem string.  
Rev. A  
- 66 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
It is recommended that the default modem initialization string be used unless the application  
requires that it be changed. The default initialization string is ATH0S0=1, which disconnects any  
active phone connections when the initialization string is sent, and sets the modem to auto-  
answer on one ring.  
7.9 Status Commands  
There are six commands which allow the sys admin to check the status of the  
SCS3230: CONNECTIONS, LISTCARDS, VERSION, INFO, POWERSTATUSand LOG.  
7.9.1 CONNECTIONS Command  
The sys admin may monitor the status of connections made through the terminal cards  
by using the CONNECTIONScommand. This command will display all the active  
connections and the mode of those connections as follows:  
sys admin>>CONNECTIONS  
Terminal Connection List  
01 KEVIN  
02  
01 SERVER  
( Monitor mode )  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
( Channel present )  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17 <not installed>  
sys admin>>  
The above example shows that user KEVIN is logged in on terminal port 01, is  
connected to device port 01 (which is named "Server" in theSCS3230), and is in  
monitor mode. The list will display the user ID of any logged-in users, the device port to  
which they are connected, the device name assigned to that port, and the mode of that  
connection (see sections 7.8, 7.9, and 7.10 for an explanation of the various connection  
modes). If the user is not connected to any device, they shall simply be listed as "User  
Logged-In".  
When used with the /MONITORcommand line qualifier, the CONNECTIONScommand  
updates the connection list on screen every time a user logs in or out or changes login level  
(i.e., goes into direct mode), rather than simply displaying the list once as occurs when the  
15.00.038  
- 67 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
CONNECTIONScommand is used alone. (See section 6.8, Sys Admin Session Management  
Commands).  
The CONNECTIONScommand will also tell the sys admin which terminal ports are  
present (in the list, they are referred to as "channels"). If the port is not functioning (i.e.,  
the card is not present or there is a fault with the individual port), the port will be listed  
as "<not installed>". It will also list Telnet Active for an active Telnet session.  
7.9.2 LISTCARDS Command  
Sys admin>>LISTCARDS  
Installed cards  
Slot A : <card not installed>  
Slot B : Terminal card installed  
Slot C : Terminal card installed  
Slot D : Terminal card installed  
Slot E : Terminal card installed  
Slot F : Switch card 1 installed  
Slot G : Switch card 2 installed  
Slot H : Device card installed  
Slot I : Device card installed  
Slot J : Device card installed  
Slot K : Device card installed  
Slot L : Device card installed  
Slot M : Device card installed  
Slot N : Device card installed  
Slot O : Device card installed  
sys admin>>  
The LISTCARDScommand will simply tell the sys admin which cards are plugged into  
the SCS3230 chassis. It only lists the cards (by type) as present or not present, and  
does not indicate whether the cards are functioning properly.  
7.9.3 VERSION Command  
sys admin>>VERSION /ALL  
SCS3230  
Slot B1: V2.15 10/01/99 Terminal Boot V1.62 (Sep 30 1999) (14:33:12)  
Slot C1: V2.15n 10/01/99 Net Terminal Boot V1.62 (Sep 30 1999) (12:44:32)  
Slot C2: V1.16 Build 7 09/29/99 Network Boot V1.62 (Sep 30 1999) (14:45:52)  
Ethernet Address: 00-30-31-00-01-D5  
Slot F1: V 1.03 Switch 1  
Slot G1: V 1.03 Switch 2  
Slot H1: V2.15 10/04/99 Device Boot V1.62 (Sep 30 1999) (14:40:51)  
Slot P1: V2.12 Build 15 10/01/99 Control Boot V1.62 (Oct 01 1999) (11:13:06)  
sys admin>>  
By itself, the VERSIONcommand lists the boot and flash software version for the control  
card. The version information for a single card other than the control card may be  
displayed by typing the card slot letter ID after the VERSIONcommand. If the sys admin  
Rev. A  
- 68 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
desires to list the software version for all cards, he should type VERSION /ALLat the  
command prompt. This will list the versions of the boot and flash software for all cards,  
listed by card slot letter designation. Each network card will display two sets of software  
versions: one set for the network portion of the card and one for the user terminal  
portion, while all other cards will only return one set of version information.  
7.9.4 INFOCommand  
sys admin>>INFO A  
Slot A1: Modem: No Active Call Timeout = 1 mins.  
Current Modem State: in command mode  
Modem Init String: ATH0S0=1  
Modem error: none  
sys admin>INFO C  
Slot C2: 0 Active Telnet Sessions Timeout = 1 mins.  
Ethernet Address: 00-30-31-00-00-4F  
IP=172.16.1.31 SM=255.255.255.0 GW=172.16.1.151  
2nd route: IP=255.255.255.255 SM=255.255.255.255 GW=255.255.255.255  
sys admin>>INFO D  
Slot D1:  
Port 9(A) DCE 38400,N,8,1 Flow=XON/XOFF RTS=0 DTR=1  
Port 10(B) DCE 38400,N,8,1 Flow=XON/XOFF RTS=0 DTR=1  
Port 11(c) DCE 38400,N,8,1 Flow=XON/XOFF RTS=0 DTR=1  
Port 12(D) DCE 38400,N,8,1 Flow=XON/XOFF RTS=0 DTR=1  
sys admin>>  
The INFOcommand allows the sys admin to list the properties of a card. The switch cards are  
incapable of returning information, and any request to view information from the switch cards  
will be refused.  
The INFOcommand is used in the form INFO <slot letter>, where <slot letter>is  
the letter designation of the card slot in the SCS3230 chassis. The modem card will always be  
in card slot A, while the network card may be in slots B, C, D, or E.  
The modem card will return the following information:  
·
·
·
·
·
·
The slot letter and processor number (which will always be "A1")  
The connection status of the modem  
The current modem session timeout limit (see Section 6.9,Breaking User Connections)  
The current modem state, listed as either power-up mode or command mode  
The modem initialization string sent at startup  
Any miscellaneous modem error messages  
The network card will return the following information:  
·
·
·
·
The slot letter and processor number (the number will always be “2”)  
The amount of active telnet sessions  
The telnet session timeout limit  
Sys Admin sessions  
15.00.038  
- 69 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
·
The unique hardware (MAC) address of the card, expressed as six groups of one-byte  
hexadecimal numbers  
·
·
·
IP source 3200, BootP, RARP  
The primary IP information, including: IP address, subnet mask, and gateway  
The secondary IP information, including: destination address, subnet mask, and gateway  
The terminal and device cards will return the following information:  
·
·
·
·
·
·
·
·
·
·
The terminal or device port number  
The port letter as indicated on card label  
Equipment port type (DCE or DTE)  
Baud rate  
Parity; N=none, E=even, O=odd  
Data bits  
Stop bits  
Flow control type  
Status of RTS line; 0=off, 1=on  
Status of DTR line; 0=off, 1=on  
The labels “RTS” and “DTR” do not change when the port type is changed from DCE to DTE.  
When the port type is changed, the label “RTS” indicates the status of the CTS line, and “DTR”  
indicates the status of the DSR line.  
7.9.5 POWERSTATUS Command  
sys admin>>powerstatus  
Power supply A is OK  
Power supply B is OK  
sys admin>>  
The POWERSTATUScommand displays the status of the two redundant power supplies in the  
SCS3230 chassis. Power supplies will either be listed as OKor Failed. The SCS3230 will  
continue to function with one failed power supply. Contact Lightwave for information regarding  
replacement if a power supply fails.  
7.9.6 LOGCommand  
sys admin>>log /enable  
The SCS3230 can report current system activity through control card port B. The report is  
enable using the command LOG /ENABLE, and disabled using the command LOG /DISABLE.  
The system will report user logins, logouts, device port selections, and entry/exit from direct  
mode. Note that there is no system clock on the SCS3230, so there is no time/date stamp on  
system activity. If a time/date stamp is required, it must be provided by the system capturing  
the data output.  
Rev. A  
- 70 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
Connection instructions for the logging port:  
1.  
Turn on power to the terminal or computer. If using a computer, start the desired  
communication program. The terminal or communications program used must  
be in VT100 emulation mode  
2.  
Ensure that the communications settings are correct. The factory defaults for the  
control card, which may only be changed by a hardware DIP switch, are 9600  
baud, 8 data bits, 1 stop bit, and no parity (9600 8N1). If in doubt as to the  
current communication settings on the control card, check the DIP switches and  
refer to Figure 2, Control Card Layout with DIP Switch Settings, on page 9.  
3.  
Locate the serial port on the terminal or computer and determine what type of  
connector is used. The cable kit included with theSCS3230 contains each of the  
following: one RJ45 serial cable, an RJ45 to male DB9 adapter, an RJ45 to  
female DB9 adapter, an RJ45 to male DB25 adapter, and an RJ45 to female  
DB25 adapter. Select the appropriate adapter for the serial port on the terminal  
or computer.  
4.  
5.  
Firmly seat the adapter in the serial port. Screw down the adapter to secure it to  
the serial port.  
Insert one end of the serial cable into the adapter until a click is heard. Insert the  
other end of the serial cable into port "B" of the control card, again until a click is  
heard.  
6.  
7.  
At the sys admin>>prompt, enter the command LOG /ENABLE. Log in as a  
user as outlined in chapter 7. Check for output on the logging port. If no output  
has appeared, check all cable connections. If “garbage” characters appear,  
check that all communications parameters match.  
The SCS3230 will continue to output logging information through the “B” port of the  
control card until the command LOG /DISABLEis entered at the sys admin>>prompt.  
Configure any text captures or scripts as needed to receive the logging data.  
7.10 Sys Admin Session Management Commands  
The SCS3230 features two commands that allow the sys admin to manage properties of the  
control port terminal session.  
15.00.038  
- 71 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
7.10.1  
LINESPERPAGE Command  
sys admin>>linesperpage  
Lines per page set to 22  
sys admin>linesperpage 10  
Lines per page set to 10  
sys admin>>  
The LINESPERPAGEcommand allows the sys admin to change the number of lines displayed  
per terminal page on the control card port before the MOREprompt is displayed. The number of  
lines to display per page is entered after the command. Entering the command without a  
number following will display the current number of lines displayed per page. The default value  
is 22, which will work properly with a 24-line display.  
7.10.2  
TIMEOUT Command  
sys admin>>TIMEOUT  
Timeout set to 1 minutes  
sys admin>>TIMEOUT 0  
Timeout set to 0 minutes  
0 disables the timeout from occurring  
sys admin>>TIMEOUT 5  
Timeout set to 5 minutes  
sys admin>>  
The TIMEOUTcommand allows the sys admin to define a time limit on how long an idle sys  
admin terminal may remain logged in. If there is no interaction for the defined amount of time,  
the control card will log out the sys admin. The time limit in minutes is entered as a command  
qualifier after the command, and must be entered as a whole number. Defining the time limit as  
0 will disable this function. The default value is one minute.  
7.11 Breaking User Connections  
The sys admin has four commands available to forcibly break user connections to  
devices. The commands BREAKand FORCELOGOUTallow the sys admin to break any  
connection on demand, while TELNETTIMEOUTand MODEMTIMEOUTautomatically  
break idle user sessions for the network or modem card.  
Rev. A  
- 72 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
7.11.1  
BREAK Command  
sys admin>>BREAK 1  
Break this connection? (write out YES) Yes or No: No>yes  
sys admin>>  
The BREAKcommand allows the sys admin to disconnect a user from the device port to  
which they were connected if they are in monitor, listen, or direct mode. The user is still  
logged in after the connection is broken, but there is no longer any connection between  
the terminal port and the device port. The sys admin must specify the terminal port  
number (as listed with the CONNECTIONScommand) ofthe connection to be severed  
when using the BREAKcommand. Pressing <ENTER>or typing NOat the confirmation  
prompt will abort the command. To execute the command, enter YESat the  
confirmation prompt.  
7.11.2  
FORCELOGOUT Command  
sys admin>>FORCELOGOUT 1  
Force this user off? (write out YES) Yes or No: No>yes  
sys admin>>  
The FORCELOGOUTcommand causes the forcible logout of a user at any level of  
connection. The user will be returned to the LCI3200>prompt after being forced off,  
and may login again unless their allowed logins are reduced to 0 before they can  
attempt another login. When using the FORCELOGOUTcommand, the sys admin must  
specify the terminal port number (as listed with the CONNECTIONScommand) of the  
user to be forced off. Pressing <ENTER>or typing NOat the confirmation prompt will  
abort the command. To execute the command, enter YESat the confirmation prompt.  
sys admin>>FORCELOGOUT SYSADMIN B  
Force logout sys admin? (write out YES) Yes or No: No>yes  
sys admin>>  
The FORCELOGOUT command may also be used to disconnect a network sys admin  
session. The qualifiers SYSADMINand the network card slot ID must be specified after  
the command.  
15.00.038  
- 73 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
7.11.3  
TELNETTIMEOUTCommand  
sys admin>>TELNETTIMEOUT  
Timeout set to 5 minutes  
Sys admin>>TELNETTIMEOUT 0  
Timeout set to 0 minutes  
0 disables the timeout from occurring  
sys admin>>TELNETTIMEOUT 2  
Timeout set to 2 minutes  
sys admin>>  
The TELNETTIMEOUTcommand allows the sys admin to define the amount of time that a  
network card may have an idle telnet session before breaking the network connection. A telnet  
session is considered to be idle if no characters are sent from the user’s terminal. Once the  
time limit has been reached, the user will be logged out and the network connection will be  
broken. The connection will be broken if there is no activity at any login level (from logged out  
up to direct mode). This is intended to prevent a “dead” session from tying up system  
resources. This command will define the idle time limit for all network cards present in the  
chassis.  
To display the current system value for the idle telnet session time limit, type TELNETTIMEOUT  
at the command prompt. To change the time limit, the command is entered in the form  
TELNETTIMEOUT<t>, where <t>is the time limit in whole minutes. The valid range for <t>is  
0 to 30, with the default value set as 1. If the value is set to 0, then the time limit is disabled.  
7.11.4  
MODEMTIMEOUT Command  
Sys admin>>modemtimeout  
Timeout set to 5 minutes  
Sys admin>>modemtimeout 0  
Timeout set to 0 minutes  
0 disables the timeout from occurring  
Sys admin>>modemtimeout 2  
Timeout set to 2 minutes  
sys admin>>  
The MODEMTIMEOUTcommand is identical to the TELNETTIMEOUTcommand, but causes the  
automatic disconnection of idle modem card sessions. The modem card will deselect any  
currently selected device port channel, log the user out, and disconnect the telephone  
connection once the idle session time limit has been reached. Entering the time limit in whole  
minutes after the command sets the idle time limit. Entering a value of 0 will disable the  
timeout. Entering the command by itself will display the current modem idle call time limit.  
Any users listening to a connection that is broken by BREAK, FORCELOGOUT,  
TELNETTIMEOUT, or a MODEMTIMEOUTwill lose the connection as well.  
Rev. A  
- 74 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
8: User Access and Interface  
8.1 Terminal Card  
Each terminal card has four (4) RJ45 connector ports to which a terminal may be attached,  
giving a maximum of 16 physically connected terminals per SCS3230 unit. The terminal card  
may be installed in slots B, C, D, or E.  
To access servers through the SCS3230 terminal card, the user must have at least a text  
terminal capable of serial communication, a serial cable terminating in an RJ45 connector, and  
the proper serial communication settings as determined by the system administrator. The  
default communication settings are 38400, N, 8, or 1.  
Once the hardware is properly connected and configured, the user may issue commands to the  
terminal card. Before entering any commands, the user should be sure that the terminal card is  
ready to accept commands by checking that there is a prompt on screen. This is best  
accomplished by pressing <ENTER>until a prompt appears on the screen (a prompt will not  
appear on the screen if the terminal port is in direct mode, or if the serial cable is not connected  
properly).  
8.2 Network Card  
The network card must be connected to a network that uses TCP/IP. There is one 10/100 IP  
Network port, part of the NETWORK/CONTROL card.  
Network settings are entered via the Sys Admin port.  
To connect to the SCS3230 network card, the user should use a TCP/IP telnet client to telnet to  
the IP address assigned to the network card.  
OCTANE_65 10# TELNET 172.16.1.31  
Trying 172.16.1.31...  
Connected to 172.16.1.31  
Escape character is ‘^]’.  
Welcome to the SCS3230  
You are connected to Port 5 via 172.16.1.31  
LCI3200>  
15.00.038  
- 75 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
The user interface for the network card is exactly the same as that for the terminal card, with a  
few minor exceptions. When a user first connects to the network card, the card will display  
Welcome to the Console Server 3200, the SCS3230 terminal port number for the  
connection, and the IP address of the network card. Once at the LCI3200>prompt, the user  
interface behaves exactly the same as for the terminal cards.  
At power-up, the network card does not respond to network connect requests until the  
control card has completed its system initialization. Once the power-up sequence is  
complete, the network card obtains its network parameters from the control card, and is  
ready to accept connections over the network. It is important to note that the network  
card does not retain its network parameters (i.e., IP address, subnet mask, gateway  
address) if moved from one card slot to another. The network parameters remain  
assigned to a card slot, and will be assigned to whatever network card is in that slot.  
8.3 Modem Card  
The modem card allows users to remotely access the servers attached to theSCS3230  
via a dial-up connection. The modem automatically detects the connection speed, and  
allows connections of up to 38.4K baud. The control card must complete its start-up  
initialization check before a user may access the SCS3230 through the modem card.  
The modem card must be installed in card slot "A" of the SCS3230 chassis. The  
modem card will not function if it is inserted in any other card slot, nor will any other card  
type function in slot A. To connect the modem card to the telephone network, insert an  
ordinary telephone cable (RJ11) in the jack on the modem card, and insert the other  
end in a telephone network jack, as outlined in section 5.3. See section 6.6 for  
instructions on setting the modem initialization string.  
The user interface for the modem card is identical to that found on the terminal card with  
the exception of one command, which is outlined below. Only one user at a time may  
connect to the modem card.  
8.3.1 The ByeCommand  
A user may disconnect from the modem card and automatically log out from the SCS3230 by  
sending the BYEcommand. This command will work at any login level that the user may send  
commands to the SCS3230 (i.e., logged out, logged in, and monitor mode). When the  
command is received, the modem card disconnects the telephone connection, and then logs the  
user out from the SCS3230. This command is unique to the modem card user interface.  
Rev. A  
- 76 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
8.4 Overview of Commands  
Several levels of access are available to the user, from simple access of the SCS3230 to direct  
access of servers attached to the SCS3230. Many of the commands are sensitive to which  
level the user is in, and not all commands are available at all levels.  
The first prompt the user should see after connecting to the SCS3230 is the LCI3200>prompt  
(additional information may be on the screen as indicated in the sections above). This indicates  
that the user is not currently logged in and that no servers may be reached through the  
SCS3230. The prompt will change to reflect the level in which the user is, and in monitor mode,  
will also indicate which server is selected.  
The help screens also change according to the user's login level. There are separate  
help screens for a logged out user, a logged in user, and a user in monitor (a.k.a.  
device) mode.  
LOGGED OUT HELP:  
F1 - Display Help Screen  
(VT100 mode)  
F2 - Display Pull Down Menu (VT100 mode)  
TTY COMMANDS:(LOGGED OUT MODE)  
LOGIN  
INFO  
- Login with ID and Password  
- Display System Info  
LOGGED IN HELP:  
F1 - Display Help Screen  
(VT100 mode)  
F2 - Display Pull Down Menu (VT100 mode)  
TTY COMMANDS: (LOGGED IN MODE)  
LOGOUT,LOGOFF  
- Logout  
SELECT [SERVER NAME\#] - Select a server by name or number  
LISTEN [SERVER NAME\#] - Listen to a server by name or number  
DISELECT[SERVER NAME\#] - Select a server and enter direct mode  
CHANGEPSWD or PASSWD  
CONNECTIONS  
DEVLIST  
- Change user password  
- Display connections list  
- Display installed devices list  
- Edit direct mode escape sequence  
- Edit Break generation escape sequence  
EDITESC  
EDITBRK  
15.00.038  
- 77 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
MONITOR (A.K.A. DEVICE) MODE HELP:  
F1 - Display Help Screen  
(VT100 mode)  
F2 - Display Pull Down Menu (VT100 mode)  
TTY COMMANDS: (MONITOR MODE)  
LOGOUT,LOGOFF  
- Logout  
SELECT [SERVER NAME\#] - Select a server by name or number  
LISTEN [SERVER NAME\#] - Listen to a server by name or number  
DISELECT[SERVER NAME\#] - Select a server and enter direct mode  
EXIT  
- Deselect from a server  
DEVLIST  
- Display installed devices list  
- Go to begining of device buffer  
- Go to end of device buffer  
- Display next page of device data  
- Display previous page of device data  
- Go forward n lines and display page  
- Go reverse n lines and display page  
- Display entire contents of device buffer  
- Display entire contents of device buffer with  
filter  
TOP  
BOTTOM  
NEXT  
PREVIOUS  
FORWARD [n LINES]  
REVERSE [n LINES]  
CAT  
CAFILTER  
CLEAR  
- Clear device buffer  
DIRECT  
- Enter direct mode  
The user may see a complete list of available commands at any prompt by typing HELP, H, or ?  
and pressing <ENTER>, by pressing <F1>, or by selecting DISPLAY HELP SCREEN from a  
pull-down menu. To use the pull-down menu of commands available at each user level, the  
user may press <F2>or <CTRL>+D. By using the up and down arrow keys, the user may move  
the highlight bar to the desired command, and then press <ENTER>to select that command.  
The user may use the <F1> and <F2> keys only if the terminal or terminal emulation supports  
VT100 function keys. If the terminal or emulation program does not support VT100 function  
keys, then the user may press the <CTRL> and Dkey simultaneously to use the pull-down  
menu. To exit from a menu without selecting a command, press <ESC><ESC>or <CTRL>+C.  
Pressing <CTRL>+U(the control and Ukey simultaneously) will erase all typed commands on  
the current command line back to the system prompt. Pressing <CTRL>+Rretypes the last  
command executed and waits for the user to hit <ENTER>to execute it.  
Use <CTRL>+F for the down arrow and <CTRL>+Efor the up arrow.  
Most commands may be abbreviated to one extent or another. See Appendix E for allowed  
abbreviations.  
Rev. A  
- 78 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
8.5 Logging In and Changing Passwords  
F2 PULL-DOWN MENU SHOWING INITIAL MENU CHOICES  
+-----------------+  
¦ LOGGED OUT MENU ¦  
+-----------------¦  
¦ USER LOG IN ¦  
¦ SYSTEM INFO ¦  
¦ DISPLAY HELP ¦  
+-----------------+  
To login, the user must type LOGINat the LOGGED OUT>prompt or select USER LOG IN from  
the pull-down menu. The user ID may also be entered as a command qualifier after the login  
command.  
LOGGED OUT>LOGIN  
Please Enter User ID user_ID  
Please Enter Password ****  
- OR -  
LOGGED OUT>login user_ID  
Please Enter Password ****  
If using the pull-down menu or if no user ID was entered as a qualifier, the SCS3230 will the  
prompt the user for their user ID by displaying Please Enter User ID. At this prompt, they  
should type the user ID assigned to them by the system administrator. After the user has  
entered their ID, they will be prompted for their password when the SCS3230 displays Please  
Enter Password. On the first login, this will be a password assigned by the system  
administrator. The password is case sensitive, so the user must be sure to type the password  
exactly as it is in the system. The SCS3230 will only echo stars for each character typed at the  
password prompt. Once the user has entered their password, the screen will clear, and a  
prompt displaying their user ID will appear, indicating that the SCS3230 is ready for use. For  
example, a user with an ID of "GEORGE" will have a prompt of GEORGE>once they have  
logged in.  
When a user profile is created by the sys admin, the password is pre-expired.  
The user must change the password assigned by the sys admin before selecting  
a device or listening to a device port for the first time.  
To change the password, the user must use the command CHANGEPSWDor PASSWD. The  
SCS3230 will first prompt the user for the old password by displaying PLEASE ENTER OLD  
PASSWORD. At this prompt, the user should enter the old password and press <ENTER>. The  
SCS3230 will then prompt the user for the new password by displaying the prompt PLEASE  
ENTER NEW PASSWORD. The user should enter the new password (which may be up to ten  
15.00.038  
- 79 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
alphanumeric characters and is case-sensitive) at this prompt and press <ENTER>. After  
entering the new password, the user will be asked to verify the new password by the prompt  
PLEASE VERIFY PASSWORD. The user should enter the new password again at this prompt  
exactly as it was typed the first time and press <ENTER>. If both new password entries match,  
the SCS3230 will display New password accepted.on the screen and return to the user  
prompt. If the new entries do not match, the message New and verify password  
mismatchis displayed, the new password is rejected, and the old password remains valid.  
The SCS3230 will also reject a new password if the incorrect password is entered when  
prompted for the old password, or if the new password is the same as the old password.  
8.6 Logging Out  
A user may logout at any time that commands may be made to the SCS3230 by typing LOGOUT,  
LOGOFF, or by selecting LOGOUTfrom a pull-down menu. When a user is connected to a server  
and they logout, the connection to that server will be broken and any other users that are  
listening to that session will lose their connection to that server as well.  
8.7 Checking Connections  
CONNECTION INFO SCREEN  
+---------------------------------------------------------------------------+  
¦
CONNECTION INFO  
+---------------------------------------------------------------------------¦  
¦
¦01 - TEST  
¦02 -  
¦03 -  
¦04 -  
¦05 -  
¦06 -  
¦07 -  
¦08 -  
¦09 -  
¦10 -  
¦11 -  
¦12 -  
¦13 -  
¦14 -  
¦15 -  
¦16 -  
¦17 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
00 -  
User logged-in  
Channel present  
Channel present  
Channel present  
Channel present  
Channel present  
Channel present  
Channel present  
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
+---------------------------------------------------------------------------+  
Press Any Key To Continue ....  
Only one user at a time may connect to a device on the SCS3230, except when using listen  
mode (see Section 7.9, Listening to a Server Session for more details). Before attempting to  
select a device port, the user may desire to check if the device port is free. The CONNECTIONS  
command allows the user to list the users that are logged in, which devices they have currently  
selected, and which mode they are in. Users may also view this information by selecting  
DISPLAY CONNECTED LISTfrom the pull-down menu when logged in.  
Rev. A  
- 80 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
8.8 Selecting a Device Port  
F2 PULL-DOWN MENU TO SELECT A DEVICE PORT, PART 1  
+--------------------------+  
¦
LOGGED IN MENU  
+--------------------------¦  
¦ CONNECT TO SERVER  
¦ DIR CONNECT TO SERVER ¦  
¦ LISTEN TO SERVER  
¦ DISPLAY CONNECTED LIST ¦  
¦ DISPLAY SERVER NAMES  
¦ DISPLAY ACTIVE DEVICES ¦  
¦ LOGOUT  
¦ CHANGE PASSWORD  
¦ CHANGE DIRECT MODE ESC ¦  
¦ CHANGE BREAK MODE ESC ¦  
¦ DISPLAY HELP  
¦
¦
¦
¦
¦
¦
¦
+--------------------------+  
F2 PULL-DOWN MENU TO SELECT A DEVICE PORT, PART 2  
+---------------------------------------------------+  
¦
SELECT SERVER  
+---------------------------------------------------¦  
¦
¦01 – DEVICE_1  
¦03 - DEVICE_3  
¦05 -  
¦07 -  
¦09 -  
¦11 -  
¦13 -  
¦15 -  
¦17 -  
¦19 -  
¦21 -  
¦23 -  
¦25 -  
¦27 -  
¦29 -  
¦31 -  
02 - DEVICE_2  
04 - DEVICE_4  
06 -  
08 -  
10 -  
12 -  
14 -  
16 -  
18 -  
20 -  
22 -  
24 -  
26 -  
28 -  
30 -  
32 -  
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
+---------------------------------------------------+  
To select a device port, the user must type SELECTalong with a device port name or number,  
or select CONNECT TO SERVERfrom the pull down menu, and then select the device port to be  
connected. The user must also have permission to connect to a device port as defined by the  
system administrator in their user profile. For example, to connect to a server named Alpha on  
device port 23, the user may either type SELECT Alpha, SELECT 23, or select CONNECT TO  
SERVERand then select Alphafrom the next menu that appears. If the system administrator  
has determined that the user does not have permission to access a server, the SCS3230 will  
display the message NO ACCESS TO DEVICE CHANNEL, and the connection will not be made.  
The user may exit from their current device port first by using the EXIT command or selecting  
EXIT FROM SERVERfrom the pull-down menu to free the device port for use by other users. A  
user may not select a server that is already selected by another user. When a server has been  
selected, the prompt will change to show which server has been selected by displaying the user  
ID, a dash, and then the server name in the general form USER_NAME-SERVER_NAME>. For  
example, if the user GEORGE selects Alpha, the prompt would read GEORGE-Alpha>.  
15.00.038  
- 81 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
When this prompt is displayed, the user is in monitor mode. There is no direct communication  
between the user and the server. Any output from the server is saved to a buffer that may be  
accessed by the user (see Section 7.11, Using the Buffer), but the user may issue no  
commands to the server. If the user desires to issue commands to the server, they must enter  
direct mode (see Section 7.10, Direct Mode).  
Note that when selecting a server from a pull-down menu, only those device ports that are  
installed shall be displayed.  
8.9 Listening to a Server Session  
F2 PULL-DOWN MENU TO LISTEN TO A DEVICE PORT PART 1  
+--------------------------+  
¦
LOGGED IN MENU  
+--------------------------¦  
¦ CONNECT TO SERVER  
¦ DIR CONNECT TO SERVER ¦  
¦ LISTEN TO SERVER  
¦ DISPLAY CONNECTED LIST ¦  
¦ DISPLAY SERVER NAMES  
¦ DISPLAY ACTIVE DEVICES ¦  
¦ LOGOUT  
¦ CHANGE PASSWORD  
¦ CHANGE DIRECT MODE ESC ¦  
¦ CHANGE BREAK MODE ESC ¦  
¦ DISPLAY HELP  
¦
¦
¦
¦
¦
¦
¦
+--------------------------+  
Rev. A  
- 82 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
F2 PULL-DOWN MENU TO LISTEN TO A DEVICE PORT PART 2  
+---------------------------------------------------+  
¦
SELECT SERVER  
+---------------------------------------------------¦  
¦
¦01 – DEVICE_1  
¦03 - DEVICE_3  
¦05 -  
¦07 -  
¦09 -  
¦11 -  
¦13 -  
¦15 -  
¦17 -  
¦19 -  
¦21 -  
¦23 -  
¦25 -  
¦27 -  
¦29 -  
¦31 -  
02 - DEVICE_2  
04 - DEVICE_4  
06 -  
08 -  
10 -  
12 -  
14 -  
16 -  
18 -  
20 -  
22 -  
24 -  
26 -  
28 -  
30 -  
32 -  
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
¦
+---------------------------------------------------+  
To monitor another user's server session, the user must type LISTENfollowed by the device  
port name or number, or select LISTEN TO SERVERand a device port from the pull-down  
menu. There must be a connection between a user and a device port for another user to be  
able to listen to the connection. Also, the user must have permission to listen to the server as  
defined by the system administrator in their user profile. Any user that can log in and has listen  
permission for a device port may listen to a session on that device port. If the user does not  
have permission to listen to a server, the SCS3230 will display the message NO ACCESS TO  
DEVICE CHANNEL.  
When listen mode is entered, the screen will clear, and the message LISTEN MODE, PRESS  
ANY KEY TO EXIT....will appear. To exit listen mode the user may press any key. The  
user will also exit listen mode if the connection between the other (interactive) user and the  
device port is broken.  
Note that when selecting a server from a pull-down menu, only those device ports that are  
installed shall be displayed.  
15.00.038  
- 83 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
8.10 Direct Mode  
F2 PULL-DOWN MENU SHOWING DEVICE (A.K.A. MONITOR) MODE OPTIONS  
+-------------------------+  
¦
DEVICE MODE MENU  
+-------------------------¦  
¦ ENTER DIRECT MODE  
¦ CONNECT TO SERVER  
¦ DIR CONNECT TO SERVER ¦  
¦ DISPLAY NEXT PAGE  
¦ DISPLAY PREVIOUS PAGE ¦  
¦ GOTO BEGINING OF BUFFER ¦  
¦
¦
¦
¦
¦ GOTO END OF BUFFER  
¦ CLEAR BUFFER  
¦ FORWARD N LINES  
¦ REVERSE N LINES  
¦ CAT  
¦
¦
¦
¦
¦
¦
¦
¦ CAT WITH FILTER  
¦ EXIT FROM SERVER  
¦ DISPLAY CONNECTED LIST ¦  
¦ LOGOUT  
¦ DISPLAY HELP  
¦
¦
+-------------------------+  
If a user desires to interact directly with a server rather than only monitor its output, then they  
must enter direct mode. To enter direct mode using the DIRECTcommand, the user must first  
select a device port as outlined in Section 7.8, Selecting a Server. Then at the prompt, the user  
must use the command DIRECT or select the command ENTER DIRECT MODEfrom the pull-  
down menu. The user may also select a device port and enter direct mode in one step by using  
the DISELECTcommand or selecting DIR CONNECT TO SERVERfrom the pull-down menu.  
The DISELECTcommand must have either the device port number or the name assigned to the  
port as the command qualifier; if using the pull-down menu, a prompt box will appear to select  
the device port.  
The user's terminal will then be directly connected to the server, and will act as if the terminal  
was physically connected to the server. The SCS3230 displays the last page of the device  
buffer along with a system information message indicating which device port is selected as the  
user enters direct mode.  
8.10.1  
Direct Mode Escape Sequence  
To escape from direct mode, the direct mode escape sequence must be used. The direct mode  
escape sequence is a series of two to five characters that allow the user to leave direct mode  
and return to monitor mode. The factory default for the direct mode escape sequence is <ESC>  
A(escape key, then uppercase "a"), but the user may change the sequence by using the  
command EDITESC or selecting CHANGE DIRECT MODE ESCfrom the pull-down menu at the  
user prompt. It is recommended that the user only change the escape sequence if it causes  
problems with the hardware or software used. It is also recommended that the user avoid  
combinations of the <CTRL>key and other keys, as these combinations are usually reserved for  
sending and receiving special characters through the terminal. When the user changes the  
escape sequence, a window with the hexadecimal representation of the old escape sequence  
will appear. Pressing <ESC>to exit from the edit prompt will not work; it will add additional  
Rev. A  
- 84 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
<ESC>characters (hexadecimal value 1B) to the direct mode escape sequence. If the user  
wishes to keep the old sequence, they need only to press <ENTER>. Otherwise, they should  
press backspace to delete the old characters, then enter the new sequence and press  
<ENTER>. If for some reason the selection is unacceptable, an error message will appear and  
the sequence will revert to the old character values. The escape sequence is stored with the  
user profile, therefore it is possible to have different sequences for different users. A hardcoded  
escape sequence is provided in the event that the programmed sequence is lost. It is semi-  
colon, exclamation, semi-colon, exclamation or ‘;!;!none of these characters should echo  
and no <ENTER> is required.  
Appendix F lists the hexadecimal codes for the ASCII character set.  
8.11 Using the Buffer  
F2 PULL-DOWN MENU FOR DEVICE (A.K.A. MONITOR) MODE  
+-------------------------+  
¦
DEVICE MODE MENU  
+-------------------------¦  
¦ ENTER DIRECT MODE  
¦ CONNECT TO SERVER  
¦ DIR CONNECT TO SERVER ¦  
¦ DISPLAY NEXT PAGE  
¦ DISPLAY PREVIOUS PAGE ¦  
¦ GOTO BEGINING OF BUFFER ¦  
¦
¦
¦
¦
¦ GOTO END OF BUFFER  
¦ CLEAR BUFFER  
¦ FORWARD N LINES  
¦ REVERSE N LINES  
¦ CAT  
¦
¦
¦
¦
¦
¦
¦
¦ CAT WITH FILTER  
¦ EXIT FROM SERVER  
¦ DISPLAY CONNECTED LIST ¦  
¦ LOGOUT  
¦ DISPLAY HELP  
¦
¦
+-------------------------+  
Each device port saves the output of a server to a FIFO buffer. Each buffer can store up to 64K  
of data, giving approximately 100 text pages. However, the actual amount of pages may vary  
according to the data. The user must be in monitor mode to view or clear the data stored in the  
buffer.  
user-DEVICE_1>TOP  
When at the monitor mode prompt, the user may view the contents of the buffer using the  
commands TOP, BOTTOM, NEXT, PREVIOUS, FORWARD, and REVERSE, or by selecting the  
commands DISPLAY NEXT PAGE, DISPLAY PREVIOUS PAGE, GOTO BEGINNING OF  
BUFFER, GOTO END OF BUFFER, FORWARD N LINES, and REVERSE N LINESfrom the pull  
down menu. The monitor mode prompt will appear at the bottom of the displayed buffer data,  
and the user may enter commands normally at this prompt. The prompt is prefixed with the  
position of the currently displayed screen in the buffer; the top of the buffer is indicated by TOP>,  
15.00.038  
- 85 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
the bottom of the buffer is indicated as BOTTOM>, and any other position is indicated as a  
percentage of the total buffer (e.g., 51%>).  
Connecting...  
W.O.P.R.  
LOGIN:GUEST  
PASSWORD:*****  
LOGIN FAILED  
LOGIN:SFALKEN  
PASSWORD:********  
LOGIN FAILED  
LOGIN:JOSHUA  
Greetings Professor Falken  
How are you today? Shall we play a game?  
>
TOP>usr1-DEVICE_1>  
The following table outlines the functions of the individual commands and pull down  
menu items.  
COMMAND  
MENU ITEM  
GOTO BEGINNING OF BUFFER  
FUNCTION  
displays first 24 lines of  
buffer data  
TOP  
BOTTOM  
NEXT  
GOTO END OF BUFFER  
DISPLAY NEXT PAGE  
DISPLAY PREVIOUS PAGE  
FORWARD N LINES  
displays last 24 lines of  
buffer data  
displays next 24 lines of  
buffer data  
displays previous 24 lines  
of buffer data  
skip forward N lines in  
buffer  
PREVIOUS  
FORWARD  
REVERSE  
REVERSE N LINES  
skip back N lines in buffer  
The commands FORWARDand REVERSEmust be followed by the number of lines the user wants  
to move in the buffer. The command will not execute if the number of lines is omitted.  
The user may also clear the buffer by using the command CLEARor by selecting CLEAR  
BUFFERfrom the pull-down menu. All data stored in the device buffer will be erased and is not  
recoverable. The sys admin may inhibit this ability on a per-user basis by either creating the  
user ID without this ability or editing the user parameters after the user is created.  
Rev. A  
- 86 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
The CAT and CAT WITH FILTER commands allow a user to output the content of the device  
buffer to the screen. This allows a user to capture the contents of a device buffer by using the  
telnet client/terminal emulation software’s texr capture capabilities.  
CAT outputs the data in the buffer exactly as it was received without any additional formatting.  
CAF outputs the data in the buffer by applying the same formatting that is used by the TOP,  
BOTTOM, NEXT, and PREVIOUStype commands. Characters are counted and a <CR><LF>is  
added after 80 characters if one is not found in the data. Due to the counting, escape  
sequences may not be preserved. Tabs are considered one character.  
15.00.038  
- 87 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
9: The Break Generation Sequence  
F2 PULL-DOWN MENU TO CHANGE BREAK SEQUENCE  
+--------------------------+  
¦
LOGGED IN MENU  
+--------------------------¦  
¦ CONNECT TO SERVER  
¦ DIR CONNECT TO SERVER ¦  
¦ LISTEN TO SERVER  
¦ DISPLAY CONNECTED LIST ¦  
¦ DISPLAY SERVER NAMES  
¦ DISPLAY ACTIVE DEVICES ¦  
¦ LOGOUT  
¦ CHANGE PASSWORD  
¦ CHANGE DIRECT MODE ESC ¦  
¦ CHANGE BREAK MODE ESC ¦  
¦ DISPLAY HELP  
+--------------------------+  
¦
¦
¦
¦
¦
¦
¦
The user may find it necessary to send a break to the selected server. The break generation  
sequence is a two to five character sequence. The factory default break generation sequence is  
<ESC> B(the escape key, then uppercase "b").  
The user may edit the break generation sequence in a manner similar to the direct mode  
escape sequence. The user may use the command EDITBRK or select CHANGE BREAK MODE  
ESCfrom the pull-down menu. It is recommended that the user only change the break  
generation sequence if it causes problems with the hardware or software used. It is also  
recommended that the user avoid combinations of the <CTRL>key and other keys, as these  
combinations are usually reserved for sending and receiving special characters through the  
terminal. When the user changes the break generation sequence, a window with the  
hexadecimal numerical equivalent of the old break generation sequence will appear. Pressing  
<ESC>to exit from the edit prompt will not work; it will add additional <ESC>characters  
(hexadecimal value 1B) to the break generation sequence. If the user wishes to keep the old  
sequence, they need only to press <ENTER>. Otherwise, they should press backspace or  
delete to remove the old characters, then type the new sequence and press <ENTER>. If for  
some reason the selection is unacceptable, an error message will appear and the sequence will  
revert to the old character values.  
Appendix F lists the hexadecimal codes for the ASCII character set.  
Rev. A  
- 88 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
10: Displaying System Information  
F2 PULL-DOWN MENU TO DISPLAY SYSTEM INFO  
+-----------------+  
¦ LOGGED OUT MENU ¦  
+-----------------¦  
¦ USER LOG IN ¦  
¦ SYSTEM INFO ¦  
¦ DISPLAY HELP ¦  
+-----------------+  
The user access cards are capable of displaying information about their software and  
communications settings. This information can be accessed only at the LCI3200> prompt by  
selecting SYSTEM INFOfrom the pull-down menu, or typing the command INFOor MISCat the  
prompt.  
The command line INFO/MISC commands are also available at the user prompt USER>.  
+-------------------------------+  
¦
+-------------------------------¦  
MISC. SYSTEM INFO  
¦
¦V2.15 10/01/99  
¦TERMINAL SOFTWARE  
¦Card Number\Channel = B1  
¦38,400 Baud  
¦No Parity  
¦8 Data Bits  
¦1 Stop Bit  
¦Software Flow Control  
¦Port Type = DCE  
¦
¦
¦
¦
¦
¦
¦
¦
¦
+-------------------------------+  
Press Any Key To Continue ....  
The system information appears in a pop-up window. The first two lines show the  
version of the software in flash memory and the type of software. The third line shows  
the position of the terminal or network card in theSCS3230 chassis. The next six lines  
show the current communication settings for the port. Pressing any key that sends a  
character through the terminal exits the window.  
15.00.038  
- 89 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
11: Front Panel Display Information:  
The up/down arrow keys are used to scroll through multi-page displays.  
Lightwave Communications, Inc.  
The LCD displays the panel below at power up time. This will be displayed for as long  
as five minutes while the SCS3230 is in the initialize mode.  
After the SCS3230 has gone through the initialization phase, the terminal connection list will  
automatically be displayed. To display the next panel in a function, press the down arrow on the  
SCS3230. To display the previous panel, press the up arrow.  
Rev. A  
- 90 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
Panel 2 (press down)  
Panel 3 (press down)  
Panel 4 (press down)  
The next series of panel shows the port number along with the name of the device connected to  
that port.  
Panel 5 (press down)  
15.00.038  
- 91 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
Panel 6 (press down)  
Panel 7 (press down)  
Panel 8 (press down)  
Panel 9 (press down)  
The next series of panels displays the inventory of cards that are installed in the chassis.  
Rev. A  
- 92 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
Panel 10 (press down)  
Panel 11 (press down)  
Panel 12 (press down)  
The last panel displays the status of the power supplies.  
Panel 13 (press down)  
15.00.038  
- 93 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
12: Appendix A – Command  
Abbreviations  
Most, but not all, commands available on the SCS3230 may be abbreviated. The  
following list outlines the allowed maximum abbreviations for all commands. Command  
qualifiers for a command may be found immediately below that command.  
Sys Admin Commands:  
command  
abbreviation  
adduser  
backup  
break  
addu, au  
backup  
break  
changepswd  
connections  
/monitor  
deleteuser  
devices  
/all  
edituser  
forcelogout  
help  
passwd, pswd  
c
/m  
deleteu  
dev  
/a  
editu, eu  
forcelogout  
h, ?  
info  
lciupdate  
/tftp  
linesperpage  
listcards  
listdevices  
listusers  
/all  
info  
lciupdate  
/tftp  
linespp, lines, lpp  
listc, lc  
listd, ld  
listu, lu  
/a  
login  
logi  
lo  
modem  
modemt, mt  
net  
logout, logoff  
modem  
modemtimeout  
network  
/all  
/a  
powerstatus  
telnettimeout  
terminals  
/all  
timeout  
version  
/all  
po, ps  
telnett, tt  
term  
/a  
time  
ver  
/a  
Rev. A  
- 94 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
Terminal, Network, and Modem Commands:  
command  
bottom  
bye  
changepswd  
clear  
connections  
devlist  
direct  
diselect  
editbrk  
editesc  
exit  
abbreviation  
bo  
bye  
ch  
cl  
co  
de  
dir  
dis  
editb  
edite  
ex  
forward  
listen  
login  
logout, logoff  
next  
passwd  
previous  
reverse  
select  
f
li  
logi  
logou, logof  
n
pa  
pr  
r
se  
t
top  
15.00.038  
- 95 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ConsoleServer 3200 System  
Lightwave Communications  
13: Appendix B – Hexadecimal ASCII  
Code  
Equivalent characters in italics are non-printing characters or signals.  
Hexadecimal  
Code  
Equivalent  
Character  
Hexadecimal  
Code  
Equivalent  
Character  
00  
01  
02  
03  
04  
05  
06  
07  
08  
09  
0A  
0B  
0C  
0D  
0E  
0F  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
1A  
1B  
1C  
1D  
1E  
1F  
NUL  
SOH  
STX  
ETX  
EOT  
ENQ  
ACK  
BEL  
BS  
HT  
NL  
VT  
NP  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
2A  
2B  
2C  
2D  
2E  
2F  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
3A  
3B  
3C  
3D  
3E  
3F  
SP  
!
#
$
%
&
(
)
*
+
,
CR  
SO  
SI  
-
.
/
DLE  
DC1  
DC2  
DC3  
DC4  
NAK  
SYN  
ETB  
CAN  
EM  
SUB  
ESC  
FS  
GS  
RS  
0
1
2
3
4
5
6
7
8
9
:
;
<
=
>
?
US  
Rev. A  
- 96 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Lantronix Company  
SCS3230 System Administrator's Guide  
Hexadecimal  
Code  
Equivalent  
Character  
Hexadecimal  
Code  
Equivalent  
Character  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
4A  
4B  
4C  
4D  
4E  
4F  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
5A  
5B  
5C  
5D  
5E  
5F  
@
A
B
C
D
E
F
G
H
I
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
6A  
6B  
6C  
6D  
6E  
6F  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
7A  
7B  
7C  
7D  
7E  
7F  
`
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
p
q
r
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
s
t
u
v
w
x
y
z
{
\
]
^
_
|
}
~
DEL  
15.00.038  
- 97 -  
May 2002  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lantronix Network Card XPort AR User Manual
LG Electronics Projector BX220 JD User Manual
LG Electronics Telephone aria130 User Manual
Lindy Computer Accessories 70907 User Manual
Lux Products Thermostat DHP2120 User Manual
Magnavox CRT Television HD2717C User Manual
Makita Power Screwdriver BFL201F User Manual
Master Lock Dehumidifier DH 25 User Manual
Maxxsonics Speaker AT12D2 User Manual
Memorex CD Player MD6810PLL User Manual