Lightolier Work Light C7E170HW User Manual

Calculite® HID Downlight C7E170HW  
Page 1 of 2  
7" Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam  
20" (508 mm) to 30" (762 mm)  
8-1/4"  
9-3/4"  
1
3
8
6
2
4
5
8
9
7
(210 mm)  
(248 mm)  
Top View  
(Magnetic Ballast)  
8-1/2"  
Vertical Adjustment:  
5/8" (16 mm) to  
2 7/8" (73 mm)  
(216 mm)  
20" (508 mm) to  
30" (762 mm)  
9-3/4"  
(248 mm)  
11" (280 mm)  
(100/150W)  
7-3/8" (187 mm) Dia.  
8-5/8" (200 mm) Dia.  
Top View  
(Electronic Ballast)  
2" (50 mm) max.  
Ceiling Thickness  
Ceiling Cutout: 8" (203 mm) Dia.  
Reflector Trim  
C7E17OHW CLW  
Frame-In Kit  
Lamp (Coated, Ceramic MH)  
Specular Clear, White Painted Flange.  
Specular Clear, Matching Flange.  
C770MHOE1 Electronic 120V C770MHOE2 Electronic 277V 70W E17, ED17, BD17, (Open Rated)  
C710MHOE1 Electronic 120V C710MHOE2 Electronic 277V 100W E17, ED17, BD17, (Open Rated)  
CLP  
CCDW  
Comfort Clear Diffuse, White Painted Flange. C715MHOE1 Electronic 120V C715MHOE2 Electronic 277V 150W E17, ED17, BD17, (Open Rated)  
CCDP  
CCZW  
CCZP  
Comfort Clear Diffuse, Matching Flange.  
Champagne Bronze, White Painted Flange.  
Champagne Bronze, Matching Flange.  
C770MHOU Magnetic 120V/277V  
C710MHOU Magnetic 120V/277V  
C715MHOU Magnetic 120V/277V  
70W E17, ED17, BD17, (Open Rated)  
100W E17, ED17, BD17, (Open Rated)  
150W E17, ED17, BD17, Open Rated)  
Features  
Electrical (cont.)  
Ballast  
ANSI Code Voltage Max. Amps Input Watts  
1. Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide  
beam distribution. Provides 50° visual cut-off to lamp and lamp image;  
self-flange in painted white or aperture-matching polished flange.  
Consult factory for other finishes.  
70W MH M98/M139 120/277  
100W MH M90/M140 120/277  
150W MH M102  
0.67/0.29  
0.90/0.43  
1.40/0.61  
78  
110  
167  
120/277  
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, HX-HPF  
circuit type, high power factor, sound rating "B", -20°F minimum starting  
temperature, Type 1 Outdoor rating.  
2. Socket Housing: Galvanized steel, pre-wired with medium base pulse rated  
socket. Snaps onto upper reflector for secure attachment without tools;  
unitized construction assures proper lamp alignment to optics for consistent  
performance.  
3. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed  
mounting bars.  
4. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical  
adjustment from above or below for ceilings from 0" to 2" thick. Center-line  
notches allow consistent alignment of multiple fixtures.  
5. Retention Springs: Rust resistant springs secure cone in place for quick,  
tool-less installation.  
Ballast  
ANSI Code Voltage Max. Amps Input Watts  
70W MH M98/M143 120/277  
100W MH M90/M140 120/277  
1.90/0.80  
2.40/1.10  
3.70/1.60  
94  
125  
180  
150W MH M102  
120/277  
Options and Accessories  
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. c ”A“.  
Emergency Lamp: Add suffix E to Reflector Trim and Frame-In Kit.  
See Spec. Sheet “A/E”.  
6. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism  
accommodates mounting to virtually any ceiling system using pre-installed  
mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures  
all adjustments. Alignment holes and markings allow fixture to be pre-set  
prior to installation.  
7. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to  
30" long and lock securely into position. Built-in locking tabs provide positive  
attachment to common T-bar systems. Self-centering feature simplifies  
installation in 24" O.C. grid systems. Attaches to steel or wood joists  
without accessories.  
Slope Ceiling Adapters: See Specification Sheet SCA.  
Chicago Plenum: Consult Factory.  
Fuse: (Magnetic Ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V).  
Labels  
UL (Suitable for Damp Locations), CSA, I.B.E.W. For 150W, install fixtures  
with minimum spacing: 3 feet from center-to-center of adjacent luminaries; 3  
inch from top of luminaire to overhead building member;1 1/2 feet from luminaire  
center to side building member.  
8. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V).  
Accessible from below for inspection and/or replacement without tools.  
9. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,  
90°C through branch circuit conductors; allows inspection from below.  
10. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not  
install insulation above nor within 3" (76mm) of any part of the luminaire.  
Job Information  
Type:  
Job Name:  
Cat. No.:  
Lamp(s):  
Notes:  
Electrical  
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.  
<15%, thermally and transient protected, RMI / RFI complies with FCC Part 18  
non-consumer equipment, shut-down circuit at end of lamp life, sound rating "A",  
-50°F minimum starting temperature, Type 1 outdoor rating.  
Lightolier a Genlyte Thomas Company  
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710  
We reserve the right to change details of design, materials and finish.  
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Lennox International Inc Furnace G50UHi User Manual
Lenoxx Electronics CD Player CD 107 User Manual
Lexicon CD Player RT 10 User Manual
LG Electronics Clothes Dryer DLEX800V User Manual
Lincoln Electric Welding System V275 S User Manual
Lindy Network Cables 42615 User Manual
LST Smoke Alarm 2251EIS User Manual
Magnavox TV DVD Combo 20MF251W User Manual
Makita Sander BO4552K User Manual
Manhattan Computer Products Computer Hardware 175357 User Manual