Calculite® HID Downlight C6E17OHW
Page 1 of 2
6” Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam
Ceiling Cutout: 6 9/16” (167 mm) Dia.
Reflector Trim
C6E17OHW CLW
Frame-In Kit
Lamp (Coated Ceramic, MH)
Specular Clear, White Painted Flange.
Specular Clear, Matching Flange.
Comfort Clear Diffuse, White Painted Flange.
Comfort Clear Diffuse, Matching Flange.
Champagne Bronze, White Painted Flange.
Champagne Bronze, Matching Flange.
C670MHOE1 Electronic, 120V
C670MHOE2 Electronic, 277V
C610MHOE1 Electronic, 120V
C610MHOE2 Electronic, 277V
70W E17, ED17, BD17 (Open Rated)
70W E17, ED17, BD17 (Open Rated)
100W E17, ED17, BD17 (Open Rated)
100W E17, ED17, BD17 (Open Rated)
CLP
CCDW
CCDP
CCZW
CCZP
C670MHOU
C610MHOU
Magnetic, 120V/277V 70W E17, ED17, BD17 (Open Rated)
Magnetic, 120V/277V 100W E17, ED17, BD17 (Open Rated)
Electrical (cont.)
Features
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides
wide beam distribution; can be removed for accessibility, inspection and
maintenance of ballast/junction box assembly.
Ballast
ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M139
100W MH M90/M140
120/277
120/277
0.67/0.29
0.90/0.43
78
110
2. Aperture Cone: Provides 55° visual cut-off to lamp and lamp image;
self-flange in painted white or aperture-matching polished flange. Consult
factory for other finishes.
3. Socket Cup: Galvanized steel, pre-wired with medium base pulse rated
socket. Snaps onto upper reflector for secure attachment without tools;
unitized construction assures proper lamp alignment to optics for consistent
performance.
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted,
HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum
starting temperature, Type 1 Outdoor rating.
Ballast
ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143
100W MH M90/M140
120/277
120/277
1.90/0.80
2.40/1.10
94
125
4. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed
mounting bars.
5. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures
Options and Accessories
Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet “A/E”
Emergency Lamp: Add suffix E to FIK and Reflector Trim. See Spec.Sheet “A/E”
Slope Ceiling Adapters: See Specification Sheet SCA.
Fuse (magnetic ballast): Add suffix F1 or F2 to Frame-In Kit (F1=120V F2=277V)
Chicago Plenum: Consult Factory.
6. Aperture Cone Retention Springs: Rust resistant springs secure cone in
place for quick, tool-less installation.
7. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism
accommodates mounting to virtually any ceiling system using pre-installed
mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures
all adjustments. Alignment holes and markings allow fixture to be pre-set
prior to installation.
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W.
For 100W Electronic, install fixtures with minimum spacing: 2 feet from center-to-
center of adjacent luminaries; 1/2 inch from top of luminaire to overhead building
member; 1 foot from luminaire center to side building member.
8. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30"
long and lock securely into position. Built-in locking tabs provide positive
attachment to common T-bar systems. Self-centering feature simplifies
installation in 24" O.C. grid systems. Attaches to steel or wood joists without
accessories.
9. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V).
Accessible from below for inspection and/or replacement without tools.
10.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors; allows inspection from below.
11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor,
T.H.D. <15%, thermally and transient protected, RMI / RFI complies with FCC
Part 18 non-consumer equipment, shut-down circuit at end of lamp life, sound
rating "A", -5°F minimum starting temperature, Type 1 outdoor rating.