Lightolier Work Light C3MRD User Manual

Calculite® Evolution Open Reflector Downlight C3MRD  
Page 1 of 2  
3" Aperture, MR16 (12V)  
12 5/8"  
(321mm)  
10  
4
2
5
3
6
7
9
8
Non-IC Frame:  
C3LV  
5" (127mm)  
C3LVE1  
C3LVE2  
Vertical Adjustment  
1" (25mm) to  
2 3/4" (70mm)  
5 1/2"  
(140mm)  
14 3/8"  
(365mm)  
9 5/8"  
(245mm)  
5"  
(127mm)  
Plus Ceiling  
Thk.  
Non-IC AirSeal Frame:  
C3ALV  
5" (127mm)  
C3ALVE1  
C3ALVE2  
14 3/8"  
(365mm)  
3" (76mm) Dia.  
4" (102mm) Dia.  
1/2"  
(13mm)  
2" (59mm) Max.  
Ceiling Thk.  
1
14 5/8"  
(372mm)  
10 1/8"  
(257mm)  
C3LV  
IC AirSeal Frame:  
C3AICLV  
C3ALCLVE1  
9"  
(229mm)  
9 1/2"  
(242mm)  
Flangeless Trim with  
Plaster Ring Accessory  
3/16"  
84mm)  
9" (229mm)  
3 3/8" (86mm) Dia.  
22 3/8"  
(568mm)  
1/2" (13mm)  
C3AICLV  
Ceiling Cutout: 3 1/2" (130mm) Dia.  
For Complete Fixture Order: Trim Kit + Frame-In Kit. Each Sold Separately.  
Trim Kit  
Frame-In Kit  
Lamp*  
Cone Finish  
White Flange  
Polished Flange Flangeless  
C3LV  
Non-IC  
Magnetic 120/277V 42W-65W MR16 (12V)  
C3LVE1  
C3LVE2  
C3ALV  
C3ALVE1  
C3ALVE2  
Non-IC  
Non-IC  
Electronic 120V  
Electronic 277V  
20W-65W MR16 (12V)  
20W-65W MR16 (12V)  
Clear  
C3MRD CLW  
C3MRD CCDW  
C3MRD CCZW  
C3MRD GDW  
C3MRD WHW  
C3MRD BKW  
C3MRD CLP  
C3MRD CCDP C3MRD CCDFT  
C3MRD CCZP  
C3MRD GDP  
N/A  
C3MRD CLFT  
Comfort Clear Diffuse  
Champagne Bronze  
Gold  
Matte White  
Specular Black  
Non-IC AirSeal® Magnetic 120/277V 42W-65W MR16 (12V)  
C3MRD CCZFT  
C3MRD GDFT  
C3MRD WHFT  
C3MRD BKFT  
Non-IC AirSeal® Electronic 120V  
Non-IC AirSeaElectronic 277V  
20W-65W MR16 (12V)  
20W-65W MR16 (12V)  
IC AirSeal®  
Magnetic 120V  
Electronic 120V  
20W-50W MR16 (12V)  
20W-50W MR16 (12V)  
C3MRD BKP  
C3AICLV  
C3AICLVE1 IC AirSeal®  
Note: Magnetic not recommended for residential or noise sensitive areas.  
10. Frame-In Kit: See Frame-In Kit specification sheets for more information.  
Non-IC and Non-IC AirSeal - Insulation must be kept 3"away from any parts  
of the luminaire and must not be placed above luminaire in a manner which  
will entrap heat. IC AirSeal - Luminaire may be in direct contact with thermal  
insulation.  
Features  
1. Trim Kit Aperture Cone: Low brightness; 0.040" aluminum, anodized;  
50° visual cut-off to lamp and lamp image. Hinged, and snaps on for easy  
tool-less installation. Self-flange in painted white or aperture matching  
polished flange. Flangeless trim used with Plaster Trim Ring accessory.  
Interchangeable with other 3" Evolution trims.  
Options and Accessories  
2. Lamp Support: Die-form aluminum with knurled surface for easy gripping  
during relamping. Spring tension clips hold lamp and lens and allow fast  
snap-in, snap-out relamping. Matte black finish. Accepts up to two 2" diam-  
eter accessories.  
2" dia. Color Filters/Specialty filters: See ADF2/AF2 specification sheets  
2" Dia. Louver: AL2HC  
Plaster Trim Ring (use with flangeless trim): CA3FMR  
Chicago Plenum: Consult Factory  
3. Cover Glass: High temperature, soft focus lens.  
4. Thick Ceiling Ready Brackets: Die-form steel, matte black finish. Adjust  
trim kit vertically to accommodate up to 2" thick ceiling, lockable.  
5. Lampholder: Procelain bi-pin socket. Pre-wired with No.18 AWG Teflon  
leads.  
6. Horizontal Adjustment Mechanism: Built-in ready for adjustable trim,  
matte black finish.  
7. Frame Vertical Adjustment Mechanism (C3LV): Accommodates mount-  
ing to virtually any ceiling system using pre-installed mounting bars, or 1/2"  
EMT tubing (by others). Single locking features secures all adjustments.  
Alignment holes and markings allow fixture to be pre-set prior to installation.  
Final adjustment can be made from below inside fixture.  
Labels  
U.L. (Suitable For Damp Locations), I.B.E.W.; U.S. & Foreign Patents Pending  
*Lamp wattage restriction for Non-IC: 65W for up to 1" thick ceiling, 50W for  
ceiling thickness greater than 1" (up to 2").  
Job Information  
Type:  
Job Name:  
Cat. No.:  
8. Mounting Bars (C3LV): Galvanized steel, 0.048"; pre-installed telescoping  
bars extend from 20" to 30" long and lock securely into position. Built-in lock-  
ing tabs provide positive attachment to common T-bar systems. Self-center-  
ing feature simplified installation in 24"O.C. grid systems. Attaches to steel  
or wood joists without accessories.  
Lamp(s):  
Notes:  
9. Transformer: Replaceable from below. Magnetic: 120V/277V 60 Hz. dual-  
voltage, core & coil. Note: Magnetic not recommended for residential or  
noise sensitive areas. Electronic: 120V or 277V 50/60 Hz., regulated lamp  
voltage, HPF, EMI and circuit protections, thermal auto-reset, quiet operation.  
Lightolier a Genlyte company  
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710  
We reserve the right to change details of design, materials and finish.  
© 2007 Genlyte Group LLC • E1107  
Download from Www.Somanuals.com. All Manuals Search And Download.  

KWC Indoor Furnishings K27H370000A35 User Manual
La Crosse Technology Clock WS 7075U User Manual
Land Pride Lawn Mower FD2548 User Manual
Land Pride Lawn Mower GS1548 User Manual
Lego Games 10567 User Manual
Lenovo Computer Monitor 2572HB6 User Manual
Life Fitness Home Gym SOSR User Manual
Lincoln Automobile MKT User Manual
Makita Chainsaw EA3500F User Manual
Melissa Toaster 243 028 User Manual