Lytecaster® Recessed Downlighting 1104F2632ESR
Page 1 of 1 6 3/4" Aperture 0® 1 Lt 26/32W Quad/Triple Tube Compact Fluorescent IC Remodeler
4
3
6 5/8"
2 1/4"
3 5/16"
2
5
1
7 7/16"
5"
OVERALL
HEIGHT
4"
3 7/8"
7"
APERTURE
13 3/8"
OVERALL
LENGTH
Ceiling Opening 7" diameter
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
Frame-In Kit
Reflector Trims — See Individual Reflector Trim Specification Sheets
Open Downlight
Enclosed
Wall
Washer
Voltage Lamp
Diffusers
AnodizedReflector AnodizedCone Satin Cone
Baffles
Basic White
1104F2632ESR
120V
26/32W 1143*
Quad or 1144*
1112
1112NM
1113
1113BK
1113BKNM
1113CD
1113CDNM
1113NM
1113WH
1108
1108NM
1110
1105
1171*
1121
1124
1126** (26W Only)
1134
1177SH
1185**
1186
1186WH
1135**
1135WH**
1105BNM 1170M1
1105NM
1105WH
1176
1176WH
Triple
Tube
1144CD*
1110NM
1178SH**
1190** (26W Only)
Features
Options & Accessories
AirSeal® Kit: LAS56R†
(Required for AirSeal installation.)
1. Housing: .032” (#20 ga.) UL listed for direct contact with thermal insulation.
Allows installation in ceilings up to 2" thick. Can be removed for access
to junction box, ballast and ceiling plenum. AirSeal® housing minimizes
air leakage to less than 2 CFM at 1.57 PSF (or 75pa), which complies with
Model Energy Code (Section 602.3.3) and Washington State Energy Code
(Section 502.4) and reduces heat loss and condensation in ceiling.
2. Junction Box: 2" X 4" X 3 1/2" (22 cu. in.) .032" (#22 ga.) galvanized steel.
UL listed for branch circuit wiring supplying connected luminaires. Integral
cable clamps permit attachment of non-metallic (#12 or #14 ga.) Romex®
cable without tools or additional connectors.
Labels
UL (Type IC Suitable for Damp Locations)
†Complies with Air Leakage Requirements stated in the Model Energy Code,
California Title 24 and the Washington State Energy Code when used with
LAS56R.
3. Socket Housing: Trim retaining spring secures trim to any height on
housing wall.
4. Socket: (4 Pin, GX24q-3) base, molded thermo-plastic. Pre-wired with
#18 AWG leads to junction box.
Romex® is a registered trademark of General Cable Industries Inc.
US and Foreign Patents Pending.
5. Ballast: Electronic 120V, end of life protected, FCC class “B” consumer
limits, class “A” sound rating. Energy Star® qualified.
Job Information
Type:
Job Name:
Cat. No.:
Electrical
Input Watts: 27
Amps: .23
*Recommend Triple Tube Lamp for Optimal Performance
**Use Triple Tube Lamp Only.
Ballast Factor: 1.0
Power Factor: .98
Max THD %: 10%
Lamp(s):
Notes:
Min Start Temp: 0˚F/ -18˚C
Lightolier a Genlyte company
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • D1006