Lightolier Indoor Furnishings 1050DSQ User Manual

Lensed Recessed CFL Downlighting  
1050DSQ  
Page 1 of 1  
5" Square, 1 Lt., CFL, Low-Profile IC Airseal® Energy Star® Dimming FIK  
14" (356 mm)  
Overall Length  
Height = 3 1/2"  
11 5/8" (295 mm)  
Overall Length  
(89 mm)  
Aperture Opening = 5 5/16" x 5 5/16"  
8 5/16"  
(211 mm)  
2
(135 mm x 135 mm)  
5
Top View  
1
13" Min  
(330 mm)  
8 1/4"  
(210 mm)  
Overall Length  
24" Max  
(610 mm)  
4
3
2
Frame-In-Kit  
6,7  
Reflector Trim  
Complete Fixture consists of Frame-In Kit and Reflector Trim. Select each separately.  
Xceed Compact Fluorescent Lensed Square Reflector Trims  
Xceed Frame-In Kit  
Lensed Downlight  
Lensed Slope/Wall Wash  
Lensed Indirect  
1050DSQ26ES*  
1050SQDLWB  
1050SQDLCDW  
1050SQDLCDP  
1050SQDLWDW  
1050SQDLWDP  
1050SQSLWWB  
1050SQSLWCDW  
1050SQSLWCDP  
1050SQSLWWDW  
1050SQSLWWDP  
1050SQINFBW  
(Energy Star® - 120v)  
26w Triple GX24q-3 Base  
120v - 0.23 amp max  
T24  
2005  
*All frames come standard with preset mounting screws and a 2700K lamp. Models are available with preset nails and/or a 3500K  
lamp. Simply add an N and/or 35 to the end of the model number for those options.  
Features  
Recommended Dimmers (Neutral Required)  
ITSEBAU: IntelliSight Occupancy Dimmer for AmbiStar Ballasts  
OS600EBA: Onset Wall Box Dimmer 600VA for AmbiStar Ballasts  
MSP600EBA: MultiSet Pro Dimmer 600VA for AmbiStar Ballasts  
Please add the following letters to part number for color option:  
W = White I = Ivory LA = Light Almond  
1. Housing: .026" (#23ga.) galvanized steel. UL listed for direct contact with  
thermal insulation. AirSeal® housing minimizes air leakage to less than 2  
CFM at 1.57PSF (or 75Pa), which complies with Title 24, the International  
Energy Conservation Code, and Washington State Energy Code (Section  
502.4). This reduces heat loss and condensation in ceiling. Access door for  
inspection of junction box.  
Recommended Lamping  
2. Lower Frame and Top Cover: .026" (#23 ga.) galvanized steel.  
Accommodates ceilings up to 1 1/2" thick. 3/8" deep integral lip with four  
notches at 90 degrees apart to simplify alignment. Locks into position along  
length of mounting bars with locking screws. Indicator lines on housing top  
and sides to simplify alignment.  
Lightolier recommends the following Philips lamps:  
943272: PLT 26W – 2700K = PHILIPS #38440-4  
943273: PLT 26W – 3500K = PHILIPS #26824-3  
3. Junction Box: 2.5" X 5 3/8" X 2" (27 cu. in) .032" (#21 ga.) galvanized steel.  
UL listed 90°C supply conductors. Rated for branch circuit wiring supplying  
connected luminaires (daisy chaining).  
Labels  
cULus Listed (Type I.C., Suitable for Damp Location), Complies with Air Leakage  
Requirements stated in the Title 24, the International Energy Conservation  
Code, and Washington State Energy Code. AirSeal® is a registered trademark  
of Lightolier.  
4. Mounting Bars: .059" (#16 ga.) galvanized steel. Bars pivot for easy  
attachment and wire-in below ceiling line. Bars extend to accommodate 16"  
to 24" O.C. joist spacing. Bars can accommodate 12" O.C. Joist spacing after a  
slight field modification (see Instruction Sheet). Features integral self tapping  
phillips/square drive SCREWS for secure attachment to wood or metal  
construction. Also available with integral NAILS. Attaches to T-bar ceilings  
without the need of accessories. Bars installed on shortest dimension of  
frame, but can be easily repositioned 90 degrees from original position.  
5. Ballast: Mounted inside Junction Box. 120V NPF Energy Star® approved  
Electronic Ballast. Instant start with end of lamp life protection, class “P”  
thermal protection with a class “A” sound rating. Ballast easily accessible  
for inspection.  
Job Information  
Type:  
Job Name:  
Cat. No.:  
Lamp(s):  
Notes:  
6. Socket: NEW TWIST & LOCK Four-pin base, molded thermoplastic socket,  
prewired with No. 18AWM leads to ballast.  
7. Socket Bracket: .048" (#18ga.) Galvanized Steel. Designed to be easily  
adjusted to accommodate 3/8" to 1 1/2" ceiling thickness. Three positions  
available for any installation orientation of Wall Washers Slope ceiling, or  
Wall mount application. Ensures Unitized optics. Reflector trim is secured to  
upper portion of socket bracket to ensure a tight to ceiling installation.  
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710  
We reserve the right to change details of design, materials and finish.  
Lightolier is a Philips group brand  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Krell Industries Stereo Amplifier KSP7B User Manual
Lenovo Personal Computer 10057 7712 User Manual
Linksys Switch EF1324 User Manual
LST Smoke Alarm 2351TEM User Manual
Magnavox DVD Player MDV443 User Manual
Makita Cordless Saw BHS630 User Manual
Manitowoc Ice Water Pump A 0100 User Manual
Marvel Industries Refrigerator 6SBARE User Manual
Mazda Automobile 2008 MX 5 Miata User Manual
Memorex MP3 Player MMP8590 BLK User Manual