Lytecaster® Recessed Downlighting 1004ICX
®
Page 1 of 1
5" Aperture 0 High Wattage Incandescent AirSeal Insulated Ceiling Frame-In Kit
1004ICXN
(Integral Nail)
Overall Length
1004ICX: "
7
16 3/8"
12 1/4"
1004ICX
(Integral Screw)
1
Overall Width
1004ICX:
Frame-In Kit
13" MIN.
24" MAX.
10 3/8"
Ceiling Opening
3
4
2
Height: 7 1/4"
Ceiling Opening: 5 1/2"
Top View
6
Reflector Trim
5
5" Aperture: Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
Frame-In Kit
Reflector Trims — See Individual Reflector Trim Specification Sheets
Open Downlight
Recessed
Reflector Cone
Satin
Cone
Baffles
Basic
White
Adjustable
Eyeball
Enclosed
Diffuser
Open
Wet Location
Wall
Washer
1004ICX
1045
1046
1012
1012NM
1008
1005
1071
1027
1022
1022WH
1023
1023WH
1082
1021
1024
1090
1084CD
1084WH
1035
1035WH
1085
1095
1096
1004ICXQ*
1004ICXN
1004ICXNQ*
1008NM 1005WH
1010 1005NM
1010NM 1005BNM
1076
1027WH
1027BK
1027CD
1027NM
1027CDNM
1027BNM
1027BKNM
1038
1046CD 1013
1013BK
1013WH
1013CD
1013NM
1013BKNM
1013CDNM
1076WH
1096CD
1038NM
1048
1048NM
*Supplied with integral push-In wire connectors
Features
Options & Accessories
Extra-Thick Ceiling
Mounting Ring:
1. Housing: .032" (#20 ga.) aluminum. UL listed for direct contact with thermal
insulation. AirSeal® housing minimizes air leak-age to less than 2 CFM
at 1.57 PSF (or 75pa), which complies with Model Energy Code (Section
602.3.3) and Washington State Energy Code (Section 502.4) and reduces
heat loss and condensation in ceiling. Access door for inspection of junction
box.
1967B - 1 1/4" to 2" thick ceilings
Labels
UL (Type I.C., Suitable for Damp Location), I.B.E.W.
Complies with Air Leakage Requirements stated in the Model Energy Code and
the Washington State Energy Code.
2. Mounting Frame: .032 (#22ga.) galvanized steel. Accommodates ceilings
up to 1" thick. 3/8" deep integral lip. Locks into position along length of
mounting bars with locking screw and bendable slot. Four slots are posi-
tioned 90° apart to simplify alignment. Push-in/twist-out roto-clips hold
reflector flush to ceiling.
3. Junction Box: 2" X 4" X 3 1/2" (22 cu. in.) .032" (#22 ga.) galvanized steel.
UL listed for maximum of 6 (#12 ga.) 90°C through branch circuit conductors.
Integral cable clamps permit attachment of non-metallic (#12 or #14 ga.)
Romex® cable without tools or additional connectors.
4. Mounting Bars: .059" (#16 ga.) galvanized steel. Bars pivot for easy attach-
ment and wire-in below ceiling line. Bars extend to accommodate 16" to 24"
O.C. joist spacing. Bars can accommodate 12" O.C. joist spacing after a slight
field modification (see Instruction Sheet). 1004ICX features integral self tap-
ping phillips screws for secure attachment to wood or metal construction.
1004ICXN features integral nails for secure attachment to wood. Both attach
to T-bar ceilings without the need of accessories.
AirSeal® is a registered trademark of Lightolier.
Romex® is a registered trademark of General Cable Industries Inc.
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
5. Socket Housing: Impact extruded aluminum or galvanized steel.
6. Socket: Porcelain medium base; nickel plated screw shell. Pre-wired with
#18 ga. SF1 (300 Volt 200° C) leads to junction box.
7. Thermal Protector: Meets NEC and UL requirements. Located inside
housing
Lightolier a Genlyte company
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • I0507
Download from Www.Somanuals.com. All Manuals Search And Download.
|