		 Single Pole (One location) or 3-Way (Multi-location)   
					Compatible with   
					TMenabled products!   
					Scene Capable Electronic Switch   
					Cat. No. RZS15-1L, (Lighted)   
					Incandescent-1800W – Magnetic Low-Voltage-1800VA (1440W)   
					Electronic Low-Voltage-1800W – Fluorescent-1800VA – Supplemental-1/2 HP   
					120VAC, 60Hz   
					DI-000-RZS15-00A-X3   
					INSTAllATION INSTRUCTIONS   
					WARNINGS AND CAUTIONS:   
					WARNINGS AND CAUTIONS:   
					• 
					• 
					• 
					• 
					To be installed and/or used in accordance with appropriate electrical codes and regulations.   
					If you are unsure about any part of these instructions, consult a qualified electrician.   
					Vizia™ RF electronic switches are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ or Vizia™ RF controllers.   
					Recommended minimum wall box depth is 2-1/2".   
					• 
					• 
					• 
					• 
					Use only one (1) ViziaTM RF electronic switch in a multi-location circuit with up to 9 ViziaTM coordinating remotes without LEDs or ViziaTM RF remotes for multi-location.   
					Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).   
					Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.   
					Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.   
					WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN   
					Single Pole Wiring Application:   
					3-Way Wiring with Coordinating Remote   
					Step 4b   
					Step 1   
					Step 4a   
					INTRODUCTION   
					OFF POWER at circuit breaker or fuse and test that power is off   
					(no lED) Application:   
					Leviton’s Vizia™ RF Z-Wave™ components are designed to communicate   
					with each other via Radio Frequency (RF) to provide remote control of   
					your lighting. Using RF technology allows Leviton to provide the greatest   
					signal integrity possible. Each module in Leviton’s Vizia™ RF component   
					line is a Z-Wave™ enabled device. In a Z-Wave™ network, each device   
					is designed to act as a router. These routers will re-transmit the RF signal   
					from one device to another until the intended device is reached. This   
					ensures that the signal is received by its intended device by routing the   
					signal around obstacles and radio dead spots. The Scene Capable Plug-In   
					Appliance Module is compatible with any Z-Wave™ enabled network,   
					regardless of the manufacturer and can also be used with other devices   
					displaying the Z-Wave™ logo.   
					before wiring!   
					Terminal   
					Screw marked   
					White (WH)   
					Terminal   
					Screw marked   
					White (WH)   
					/&&   
					/&&   
					/&&   
					/&&   
					/&&   
					/&&   
					/. /&&   
					/. /&&   
					/. /&&   
					. /&&   
					/&&   
					/ 
					/.   
					/.   
					/.   
					/.   
					/.   
					/.   
					Coordinating Remote   
					Switch   
					1 
					2 
					H 
					W 
					1 
					BK   
					Terminal   
					Screw marked   
					Black (BK)   
					H 
					W 
					BK   
					H 
					W 
					BK   
					Terminal   
					Screw marked   
					Black (BK)   
					2 
					2 
					4 
					1 
					3 
					4 
					5 
					Identifying your wiring application (most common):   
					NOTE: If the wiring in your wall box does not resemble any of   
					these configurations, consult a qualified electrician.   
					3 
					4 
					Step 2   
					3 
					5 
					Terminal   
					Screw marked   
					Yellow/Red   
					(Yl/RD)   
					RD   
					RD   
					Terminal   
					Screw marked   
					Yellow/Red   
					(Yl/RD)   
					D 
					D 
					/R   
					Yl   
					/R   
					l 
					Y 
					RD   
					D 
					/R   
					l 
					Y 
					Terminal   
					Screw marked   
					Red (RD)   
					CAUTION:   
					Single Pole   
					3-Way   
					Terminal   
					Screw marked   
					Red (RD)   
					Remember to exercise good common sense when using the Timer   
					features of your Remote – especially when scheduling unattended devices.   
					There can be some unexpected consequences if not used with care. For   
					example, an empty coffee pot can be remotely turned on. If that should   
					happen, your coffee pot could be damaged from overheating. If an electric   
					heater is turned on by remote control while clothing is draped over it, a   
					fire could result. DO NOT USE the remote for the control of high power   
					heating appliances such as portable heaters. This device will not control   
					lighting that is used with electronic low-voltage and high frequency power   
					supply transformers, nor high pressure discharge lamps (HID lighting).   
					This includes mercury-vapor, sodium vapor and metal halide lamps.   
					1. Line (Hot)   
					2. Neutral   
					3. Ground   
					4. Load   
					1. Line or Load (see   
					important instruction)   
					2. Neutral   
					2 
					1 
					Terminal label:   
					2 
					1 
					Use Terminal for 3-Way or More Applications Only.   
					For Single-Pole Applications, Do Not Remove This   
					label.   
					3 
					4 
					5 
					3. Ground   
					3 
					4 
					Switch   
					4. First Traveler – note color   
					5. Second Traveler – note   
					color   
					Coordinating Remote (no LED)   
					Switch   
					Hot (Black)   
					WH   
					BK   
					WH   
					RD   
					(unused)   
					BK   
					IMPORTANT : For 3-Way applications, note that one of the screw terminals   
					from the old switch being removed will usually be a different color (Black)   
					or labeled Common. Tag that wire with electrical tape and identify as the   
					common (Line or Load) in both the switch wall box and remote wall box.   
					Green   
					Ground   
					Green   
					Ground   
					Black   
					Hot (Black)   
					WH   
					RD   
					BK   
					RD   
					YL/RD   
					YL/RD   
					(unused)   
					Line   
					Green   
					Ground   
					Load   
					FEATURES   
					120VAC, 60Hz   
					Preparing and connecting wires:   
					This switch can be wired using side wire terminal screws or   
					through backwire openings. Choose appropriate wire stripping   
					specifications accordingly.   
					Step 3   
					YL/RD   
					• 
					• 
					• 
					• 
					• 
					• 
					• 
					Switch ON/OFF   
					Scene Capable   
					ON/OFF LED   
					Two way communication   
					RF reliability   
					Ease of installation – No new wiring   
					Compatible with other Z-Wave™ enabled devices   
					Black   
					Load   
					White   
					Line   
					120VAC, 60Hz   
					White   
					Use Terminal for 3-Way or   
					More Applications Only.   
					For Single-Pole Applications,   
					Do Not Remove This Label.   
					Neutral (White)   
					5/8"   
					WIRING SWITCH:   
					Strip Gage   
					(1.6 cm)   
					Neutral (White)   
					Connect wires per WIRING DIAGRAM as follows:   
					NOTE: The switch must be installed in a wall box that has a Line Hot   
					connection.   
					(measure bare   
					wire here)   
					Cut   
					(if necessary)   
					Tools needed to install your Switch   
					Slotted/Phillips Screwdriver   
					Pencil   
					WIRING SWITCH:   
					Connect wires per WIRING DIAGRAM as follows:   
					Electrical Tape   
					Cutters   
					Pliers   
					Ruler   
					NOTE: Maximum wire length from switch to all installed remotes cannot   
					exceed 300 ft (90 m).   
					• 
					• 
					• 
					• 
					• 
					Green or bare copper wire in wall box to Green terminal screw.   
					Line Hot wall box wire to terminal screw marked "BK".   
					Load wall box wire to terminal screw marked "RD".   
					Line Neutral wall box wire to terminal screw marked "WH".   
					Switch terminal screw marked "YL/RD" should have Red insulation   
					label affixed.   
					• 
					• 
					Green or bare copper wire in wall box to Green terminal screw.   
					Line Hot (common) wall box wire identified (tagged) when removing   
					old switch   
					Changing the color of your Switch:   
					Your switch includes three color options. The switch ships with the White   
					frame attached. To change color of frame, proceed as follows:   
					to terminal screw marked "BK".   
					First Traveler wall box wire to terminal screw marked "RD"   
					(note wire color).   
					• 
					NOTE: If insulating label is not affixed to terminal screw marked "YL/RD",   
					use electrical tape to cover.   
					Proceed to Step 5.   
					Side Wire Connection   
					Side wire terminals accept #14   
					AWG solid wire copper only.   
					Back Wire (either hole may be used)   
					Back wire openings use #14-12 AWG   
					solid wire copper only.   
					• 
					• 
					Remove Red insulating label from terminal screw marked "YL/RD".   
					Second Traveler wall box wire to terminal screw marked "YL/RD"   
					(note wire color). This traveler from the switch must go to the   
					terminal screw on the remote marked "YL/RD".   
					Line Neutral wall box wire to terminal screw marked "WH".   
					• 
					Push in   
					side at tab   
					to release   
					line up tabs   
					and press in   
					side to attach   
					• 
					Make sure that the ends of the wires from the wall box are   
					straight (cut if necessary).   
					Remove insulation from each wire in the wall box as shown.   
					For Single-Pole Application, go to Step 4a.   
					For 3-Way Coordinating Remote (no lEDs) Application, go to Step 4b.   
					• 
					• 
					• 
					• 
					INSTAllING YOUR SWITCH   
					NOTE: Use check boxes   
					when Steps are completed.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |