Leviton Surge Protector 2206 User Manual

RESIDENTIAL POWERLINE  
CARRIER COMPONENTS  
SINGLE POLE SWITCH MODULE  
INSTALLATION INSTRUCTIONS  
&
Wiring Diagram  
Cat. No. 6291  
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH  
APPROPRIATE ELECTRICAL CODES AND REGULATIONS.  
RATING: 20A-120V/ 60Hz AC ONLY  
Minimum Voltage: 112V  
Maximum Voltage: 138V  
Maximum number of Modules per circult: 10  
The module may be set to any of the 256 address  
codes, selected at the time of installation. The  
desired address Is set by removing the touchplate  
and selecting letter and number codes with a small  
blade screwdriver. The module is equipped with  
back wire terminals and installs easily in a standard  
wall box. It is suitable for incandescent and fluores-  
cent lighting, as well as switch controlled appliance  
when Dimming Is not desired.  
ENGINEERING DATA:  
Input Signal 121 kHz carrier signal superimposed  
on a 12OV AC power line.  
Mlnlmum Signal Strength: 100mV.  
The Cat. No. 6291 is assembled as white and an  
ivory color conversion kit is provlded. This product  
fits any color Decora Wallplate (sold separately).  
Additional color conversion kits are available.  
Ambient Operating Temperature: Minimum 0° F  
(-18°C) to Maxlmum 104°F (40°C).  
Ambient Humidity: 0 to 90% RH, non-condensing.  
DESCRIPTION:  
SAVE THIS INSTRUCTION SHEET!  
IT CONTAINS IMPORTANT TECHNICAL DATA,  
TESTlNG, AND TROUBLE SHOOTING INFORMA  
TION WHICH WILL BE USEFUL AFTER INSTAL-  
LATION IS COMPLETE.  
This Wall Switch Module is designed for use with  
Levlton Decora Electronic Control (DEC) Powerline  
Carder Components. It functions as a remote  
control switching device which responds to ON/OFF  
and ALL LIGHTS ON/OFF commands, from one or  
more DEC controllers remotely located from the  
module. The switch module can also be operated  
manually as a standard type wall switch.  
IMPORTANT: Unlike standard single pole wall  
switches the Cat. No. 6291 also requires a neutral  
(white) wire for operation.  
2
Home Automation Systems, Inc. (800) SMART-HOME (949) 221-9200 http://smarthome.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPLICATIONS:  
IMPORTANT NOTICE  
The Leviton power line carrier signal is designed to  
provide the greatest signal integrity and noise  
immunity possible. However, in some environments  
intense electrical noise can cause interference with  
the signal.  
Decora Electronic Controls will not control lighting  
that is used with low voltage or high frequency  
transformers, nor high pressure discharge lamps  
(HID lighting). This includes mercury vapor, sodium  
vapor, and metal halide lamps.  
Leviton has developed hardware and techniques for  
overcoming this interference when properly applied.  
It is the responsibility of the specifier/installer to test  
for signal strength and the presence of noise using  
Leviton test equipment Cat. Nos. 6385 (Signal Test  
Transmitter) and 6386 (Signal Strength Indicator)  
and to properly apply signal coupling and noise-  
reduction equipment according to the guidelines  
provided in the DEC Technical Manual and the DEC  
Troubleshooting Guide.  
DEC components can control:  
l
l
l
Low pressure dischar e lamps (fluorescent)  
(ON/OFF only) use at. Nos. 6291 and 6293  
-
120 Volt quartz lamps can be dimmed or  
brightened  
Low  
provided t  
-
use Cat. Nos. 6381 and 6383  
e lighting can be controlled  
lighting system operates with a  
e
80 Hz transformer (ON/OFF only) use Cat.  
-
Nos. 8291, 6293, 6227 and 6280 (DIMMING)  
use Cat. Nos. 6381-U and 6290  
Leviton specifically denies any warranty of perfor-  
mance, stated or implied, where electrical noise  
interference exists at the time of installation, or  
subsequent to Installation by the addition of noise-  
producing devices or equipment, or where these  
components have been installed for non-residential  
applications.  
If a power interruption should occur while the 6291 is  
ON the LOAD will remain ON when power is re-  
stored.  
4
5
INSTALLATION INSTRUCTIONS  
WIRING DIAGRAM  
For Cal. No. 6291  
1. WARNING: TO AVOID FIRE, SHOCK, OR  
DEATH; TURN OFF POWER AT CIRCUIT  
BREAKER OR FUSE. TEST THAT POWER IS  
OFF-BEFORE WIRING! Use this device only with  
copper or co per clad wire. With aluminum wire  
Single Pole Switch Module  
use only de  
marked CO/ALR. REMOVE  
BULB(S) FROM FIXTURE. Read all instruc-  
tions carefully. If you do not understand these  
instructlons, consult  
a
qualified electrlclan  
2. Remove and discard existing switch and  
wallplate, if applicable.  
3. Remove 1/2” insulation from ends of branch  
drcuft wires to expose bare copper.  
4. Connect drcuft wires to switch module per wiring  
diagram as follows: Insert wires into round  
backwfre holes. Firmly tlghten all terminal screws.  
(2) drcuft wires can be connected to  
5. Mount switch module In wall box using two  
screws provfded  
8.  
a small blade screwdriver, remove the  
Plate (front cover) by pit off at the  
6
bottom.  
Home Automation Systems, Inc. (800) SMART-HOME (949) 221-9200 http://smarthome.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Transmit an ALL LIGHTS ON control to the  
module from an appropriately coded controller.  
It (and all other devices on that House code)  
should respond by turning its assigned  
Load ON.  
Transmit an ALL OFF command from an  
appropriately coded controiier. It should  
respond by turning its assigned Load OFF.  
7. Using the same screwdriver, set the House Code  
Dial (RED) to the chosen Letter and the Unit Code  
Dial (BLACK) to the chosen Number, thus pro-  
gramming the unit with the desired address code.  
8. If it is desirable to change the color of the device,  
do so now by following the “Color Conversion  
Procedure”. If not, remount the Touch Plate by  
pressing it into position. Mount Decora Wallplate  
(sold separately).  
If a power interruption should occur while the 6291  
is ON the LOAD will remain ON when power is  
restored.  
0. Replace bulb(s) in lighting fixture. Restore power  
at circuit breaker or fuse. INSTALLATION IS  
COMPLETE. PROCEED TO TESTING.  
The DEC Single Pole Module Switch should be  
operating properly. If not, proceed to PERFECT  
PERFORMANCE  
TESTING (Performed directly after installation)  
With the Cat. No. 6291 properly wired and powered,  
tap the switch plate several times to ensure that the  
module is turning its load on and off in response to  
manual control. Next, use the Cat. No. 6320 Table  
Top Controller, or other controller, to check for the  
proper switch module operation as follows (leaving  
the load ON, manually):  
l
Transmit an OFF command to the module. it  
should respond by turning its assigned Load O F F  
9
3. Take the new touch plate and gently press it into  
place until it seats properly with a click.  
COLOR CONVERSION PROCEDURE  
The color of this  
Cat. No. 6291 can  
be changed to  
your Interior design  
requirements.  
Simply get a color  
conversion kit of the  
appropriate  
from your Levlton  
or use  
4. Take the new trim frame and position it properly  
around the touch plate. Notice that the trim frame  
has a cut-out for the indicator light.  
With the trim  
frame properly positioned, gently press it into  
place until it seats properly with a click. The color  
conversion is complete.  
PERFECT PERFORMANCE CHECKLIST  
if the 6291 seems to be functioning improperly  
confirm that the:  
1. POWER IS OFF AT CIRCUIT BREAKER OR  
FUSE. Check that the Module is wired EXACTLY  
as shown in the Wiring Diagram. Restore power  
before proceeding.  
2. Module is being supplied from a 120V/ 60Hz AC  
source ONLY.  
the one provided,  
and proceed as  
follows:  
1. The trim frame bordering the touch plate has  
notches on its sides. Place the tip of a small-  
bladed screwdriver under a notch and gently pry  
off the trim frame.  
2. The touch plate has a notch along its bottom edge  
which can be seen once the trim frame has been  
removed. Place the screwdriver tip in this  
notch and gently pry off the touch plate.  
3. Load being controlled is in proper working order.  
Local switch, ON. (Check for burned-out bulbs)  
4. Load being controlled does not exceed the  
10  
11  
20 Amp module limit.  
Home Automation Systems, Inc. (800) SMART-HOME (949) 221-9200 http://smarthome.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Module’s Letter and Number codes are set  
correctly- that they match the codes set in the  
Controller.  
1
OOmV of signal present, it may be necessary  
to couple both legs of the 120/240 volt power  
service at the entrance panel using Cat. No.  
6299 Signal Btfdge.  
6. Confirm that the controller Is powered.  
c) If the Yellow ERROR CONDITION indicator is  
lit, there is electrical noise present on the AC  
line which is interfering with proper module  
operation. The source of the noise must be  
identified and either filtered out or eliminated.  
Consult the DEC Technical Manual and DEC  
Troubleshooting Guide.  
IMPORTANT:  
If,  
after checking Items 1 through 6,  
the module still does not operate properly, the  
fault may not lie with the module itself. Follow  
steps 7 and 8 to identify the source of the problem.  
7. Set the controller to transmit address P1. Using a  
Signal Strength Indicator, Cat. No. 6386, plugged  
in at the location of the controller, Confirm that the  
controller is transmitting a minimum reading of 2  
volts of command signal at the HI-RANGE setting.  
If the signal strength Is less than 2 volts, have  
controller checked.  
6. Check for adequate command signal at the  
module location as follows:  
a) Plug the Cat. No. 6385 Signal Test Transmitter  
into a receptacle on the same circuit.  
b) Using the Cat. No. 6386 Signal Strength  
Indicator at the module location, check the  
command signal amplitude. Signal strength  
must be 1 00mV minlmum. If there is less t h a n  
DEC Components are for RESIDENTIAL USE ONLY.  
installation for any other applicatiDoonw,nvlooaiddfsromanWywww.aSrormanantyu,als.com. All Manuals Search And Download.  
stated or implied.  
Home Automation Systems, Inc. (800) SMART-HOME  
(949) 221-9200 http://smarthome.com  

KTM Motorcycle 3CF6001F5EN User Manual
La Crosse Technology Clock Radio WT 5442 User Manual
Lenovo Network Hardware 70BG9000NA User Manual
LevelOne Network Router GSW 2490TXM User Manual
LG Electronics DVD Player XBV713 User Manual
LG Electronics Refrigerator LRTN19310 User Manual
Life Fitness Flat Panel Television 0201 03 User Manual
Linear Barcode Reader AM DPR User Manual
Makita Grinder 9553B User Manual
Manfrotto Carrying Case MBAG100P User Manual