HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS
B-VENT MULTI-OPEN
ELITE® SERIES
B-VENTED GAS APPLIANCES
P/N 875,012M REV. D 05/2004
MODELS
EBST (See-through)
EBPF (Peninsula)
Millivolt Models
Electronic Models
EBSTNM-2 EBCRNM-2 EBSTNE-2 EBCRNE-2
EBSTPM-2 EBCRPM-2 EBSTPE-2 EBCRPE-2
EBPFNM-2 EBCLNM-2 EBPFNE-2 EBCLNE-2
EBPFPM-2 EBCLPM-2 EBPFPE-2 EBCLPE-2
EBBAYNM
EBBAYNP
EBBAYNE
EBCL (Corner-Left)
EBCR (Corner-Right)
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LESINSTRUCTIONSDONNÉDANSCETTENOTICEPOUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
OTL Report No. 116-F-07-5
WARNING:IFTHEINFORMATIONINTHISMANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
POURVOTRESÉCURITÉ: Nepasentreposerniutiliser
d'essencenid'autrevapeursouliquidesinflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
FOR YOUR SAFETY: What to do if you smell gas:
• Ne pas tenter d'allumer d'appareil.
• Netouchezàaucuninterrupteur. Nepasvousservir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone.
Follow your gas suppliers instructions.
• Ifyourgassuppliercannotbereached, callthe
fire department.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
L'installation et service doit être exécuté par un
qualifiéinstalleur,agencedeserviceoulefournisseur
de gaz.
Download from Www.Somanuals.com. All Manuals Search And Download.
The appliance and its individual shut-off valve must
bedisconnectedfromthegassupplypipingsystem
during any pressure testing of that system at pres-
sures in excess of ¹⁄₂ psig (3.5 kPa).
The following table shows the units' gas ori-
fice size for the elevations indicated:
WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAZARDS
OFHIGHSURFACETEMPERATURES.USE
CAUTION AROUND THE APPLIANCE TO
AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY ARE IN
THE SAME ROOM AS THE APPLIANCE.
Orifice size*
Nat. Prop.
Model
No.
Elevation
Feet (meters)
These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.
EBST-2
EBPF-2
EBBAY
#44
#47
#55
0-4500
(0-1372)
Any safety guard or screen removed for ser-
vicing the appliance must be replaced prior to
operating the appliance.
EBCR-2
EBCL-2
0.05"
WARNING: DO NOT PLACE CLOTHING
OR OTHER FLAMMABLE MATERIALS
ON OR NEAR THIS APPLIANCE.
* Each model has two burners. Each burner
contains one of these orifices.
WARNING: B-VENTAPPLIANCESARENOT
DESIGNED TO OPERATE IN NEGATIVELY
PRESSUREDENVIRONMENTS(PRESSURE
WITHIN THE HOME IS LESS THAN PRES-
SURES OUTSIDE). SIGNIFICANT NEGA-
TIVELY PRESSURED ENVIRONMENTS
CAUSED BY WEATHER, HOME DESIGN,
OR OTHER DEVICES MAY IMPACT THE
OPERATION OF THESE APPLIANCES.
NEGATIVE PRESSURES MAY RESULT IN
POOR FLAME APPEARANCE, SOOTING,
DAMAGE TO PROPERTY AND/OR SEVERE
PERSONAL INJURY. DO NOT OPERATE
THESEAPPLIANCESINNEGATIVELYPRES-
SUREDENVIRONMENTS. PROVIDINGAD-
EQUATE VENTILATION TO THE APPIANCE
FORCOMBUSTIONAIRWILLELIMINATEA
NEGATIVE PRESSURE ENVIRONMENT.
Maximum manifold pressure is 3.5 in. w.c.
(0.87kPa) for natural gasand10in. w.c. (2.49
kPa) for LP/Propane gas.
AVERTISSEMENT: SURVEILLER LES
ENFANTS. GARDER LES VÊTEMENTS,
LES MEUBLES, L'ESSENCE OU AUTRES
LIQUIDES À VAPEUR INFLAMMABLES
LOIN DE L'APPAREIL.
Do not use these appliances if any part has
beenunderwater.Immediatelycallaqualified,
professional service technician to inspect the
appliance and to replace any parts of the
control system and any gas control which
have been under water.
OPERATION AND CARE OF YOUR
APPLIANCE
Nepasseservirdecetappareils'ilaétéplongé
dansl'eau,complètementouenpartie. Appeler
untechnicienqualifiépourinspecterl'appareil
et remplacer toute partie du système de
contrôleettoutecommandequiontétéplongés
dans l'leau.
Appliance operation may be controlled by the
followingmeans:thefactoryprovidedmodesty
panel-mounted ON-OFF control switch, an op-
tionalwall-mountedON-OFFswitchoroptional
remote control.
The modesty panel mounted ON-OFF control
switch is located behind the control compart-
ment access panel, below the appliance front
glass enclosure panel. See Figure 1.
Test gage connections are provided on the
front of the millivolt gas control valve (identi-
fied OUT for the manifold side and IN for inlet
pressure. A ¹⁄₈" NPT test gage connection is
provided on the electronic gas control valve
adjacent to the outlet to the main burner.
WARNING: FAILURE TO COMPLY WITH
THEINSTALLATIONANDOPERATINGIN-
STRUCTIONS PROVIDED IN THIS DOCU-
MENT WILL RESULT IN AN IMPROP-
ERLY INSTALLED AND OPERATING AP-
PLIANCE,VOIDINGITSWARRANTY. ANY
CHANGE TO THIS APPLIANCE AND/OR
ITS OPERATING CONTROLS IS DANGER-
OUS. IMPROPERINSTALLATIONORUSE
OF THIS APPLIANCE CAN CAUSE SERI-
OUS INJURY OR DEATH FROM FIRE,
BURNS, EXPLOSION OR CARBON MON-
OXIDE POISONING.
Minimum inlet gas pressure to these appli-
ances is 5.0 inches water column (1.24 kPa)
for natural gas and 11 inches water column
(2.74kPa)forpropaneforthepurposeofinput
adjustment.
Maximum inlet gas supply pressure to these
appliances is 10.5 inches water column (2.61
kPa) for natural gas and 13.0 inches water
column (3.23 kPa) for propane.
Gas Valve
Control
Hinge
Pin
Compartment
ON/OFF
Access panel
Switch
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning are similar to
the flu with headaches, dizziness and/or
nausea. If you have these signs, obtain
fresh air immediately. Turn off the gas
supply to the appliance and have it ser-
viced by a qualified professional, as it may
not be operating correctly.
Modesty Panel
Piezo Ignitor
The appliance must be isolated from the gas
supply piping system (by closing its individual
manualshut-offvalve)duringanypressuretest-
ing of the gas supply piping system at test
pressuresequaltoorlessthan¹⁄₂ psig(3.5kPa).
Control Compartment Access -
Millivolt Control Valve Shown
Figure 1
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Remove the modesty panel carefully, so that
none of the wires become loose or discon-
nected. Now complete access to the gas con-
trol valve and its related controls is attainable.
GasControls/ControlCompartmentAccess
ON/OFF Switch
Manifold Pressure Port
The gas controls can be found behind the
control compartment access panel.
Inlet
Pressure
Port
To ease door closure, depress the catches to
place them in their retracted position, then
close the door.
Toopenthecontrolcompartmentaccesspanel,
actuate the spring-loaded magnetic catches
securing the panel, by gently depressing the
outer topcornersof thepanel until thecatches
"pop"thedoorfree,allowingittoswingoutand
down to open.
Electronic
Gas Control
Valve
Operation of millivolt and electronic gas con-
trol systems are different. Before lighting and
operatingyourappliancedetermineifyouhave
a millivolt or electronic appliance. Refer to
Figure 1 on page 4 for access to the gas
control valve. Millivolt appliances will be fitted
with the gas control valve shown in Figure 2.
Honeywell Electronic
Gas Valve
On millivolt systems, the piezo ignitor, Hi/Lo
flameadjustmentknob,andpilotandmaingas
ON/OFF control knob are located on the mod-
esty panel. On both millivolt and electronic
systems the gas valve is located behind the
modesty panel. Refer to Figure 1.
Figure 3
If your millivolt appliance is equipped with an
optional wall-mounted ON/OFF switch or re-
motecontrolkitandthepilotislit,theappliance
main burner may be turned on and off with the
wall switch or remote control.
Appliances with electronic systems will be
fitted with the electronic valve shown in
Figure 3. Familiarize yourself with the gas
control valve that your appliance uses.
Remove the bottom control compartment ac-
cess panel by compressing the spring-loaded
hinge pin on the left side until it disengages
from the left cabinet panel hole. Pull the panel
away from the fireplace.
Electronic Appliances -
To light electronic appliances refer to the de-
tailed lighting instructions found in both En-
glish and French on pages 15 and 16 of these
instructionsrespectively.Electronicappliance
lighting instructions may also be found on the
pull out lighting instruction labels attached to
the gas control valve.
Millivolt Appliances -
To light millivolt appliances refer to the de-
tailed lighting instructions found on page 13
(English) and page 14 (French). Millivolt ap-
pliance lighting instructions may also be
found on the pull out lighting instruction
labels attached to the gas control valve.
Once the control compartment access panel
has been removed, the modesty panel can be
removed as follows: pull the bottom right
corner of the modesty panel out slightly to
disengagethesnap-fitfeature;liftthemodesty
panel by the tab on the panel's right end, pull
the right end of the panel away from the
cabinet and then pull the panel diagonally out
of the left side cabinet panel slots. (In the
above procedure, reverse the words "left" and
"right" for EDCR-2 models).
Electronic appliances are fitted with a ON/OFF
burner control switch (rocker switch). See
Figure 1 on page 3 for its location. The elec-
tronic system will go through the whole light-
ing sequence automatically once the rocker
switch is toggled to the ON position.
Millivolt appliances are fitted with a burner ON/
OFF control switch (rocker switch). See Figure
1 on page 3 for its location. Once the pilot is lit,
the ON/OFF rocker switch will control the appli-
anceON/OFFoperation. Tooperate: Togglethe
switch between its ON and OFF positions.
If your electronic appliance is equipped with an
optional wall-mounted ON/OFF switch or re-
motecontrolkittheappliancemainburnermay
be turned on and off with the wall switch or
remote control.
Variable Flame Height Adjustment
Manifold Pressure Port
Inlet Pressure Port
O U T I N
I
H
F
O
F
P
I
L
O
L
O W
T
O
N
P
I
L
T
Main Gas
Control Knob
SIT Millivolt Gas Valve
Note: The piezo ignitor is located on the modesty panel - see Figure 1.
Figure 2
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION: DO NOT TOUCH THE FRONT EN-
CLOSURE GLASS WITH YOUR HANDS WHILE
THE FIREPLACE IS IN USE.
Variable Flame Height Adjustment
( Millivolt Appliances only)
WARNING: DONOTOPERATETHESHUTOFF
LEVER UNLESS A COMPLETE OUTSIDE
COMBUSTION AIR SYSTEM HAS BEEN IN-
STALLED WITH YOUR APPLIANCE.
1. All Millivolt appliances are equipped with a
variable gas control valve. Flame height for
thesemodelsmaybeadjustedthrougharange
between fixed low and high settings while the
appliance is in operation.
Outside Combustion Air Controls
Manyappliancesareequipped,wheninstalled,
with an outside (make-up air) vent system
that is designed to provide the appliance with
outside make-up air for combustion when in
operation. The outside air control lever for
the outside air system is standard on all
appliances but should not be operated if the
complete system is not installed. Refer to
Figure 4. Whenthecompleteoutsideair vent
system is installed, the installer will remove
the securing screw from the combustion air
control lever located on the right side (EBST-
2, EBPF-2 and EBCL-2), or left side (EBCR-2)
of the fireplace opening.
To open the outside air shutter, open the
botttom control access panel, reach into the
gap between the firebox bottom and the
modesty panel, and pull the outside air con-
trol lever all the way out. The outside air
shutter should be fully open when the fire-
place is in use and completely closed when
the fireplace is not being used. Closing it
when not in use will prevent outside cold air
from entering the dwelling.
Adjusttheflameheightasdesiredafterlighting
the appliance by rotating the variable adjust-
ment control knob located on the front of the
valve (refer to Figure 2). (An extension is
provided to this knob so that the adjustment
may be made at the modesty panel.)
2. When lit for the first time, this appliance will
emitaslightodorfor14hours.Thisisduetothe
“burn-in” ofinternalpaintsandlubricantsused
in the manufacturing process.
Venting Action and Safety Limit Operation
Ifyoususpectthattheapplianceisnotventing
properly, or you notice windows fogging or
sweating, you may want to conduct the fol-
lowing spillage test:
3. Keep lower control compartment clean by
vacuuming or brushing at least twice a year.
More frequent cleaning may be required due to
excessive lint from carpeting, bedding materi-
als, etc. It is important that control compart-
ments, burners and circulating air passage-
ways of the appliance be kept clean.
Ifthesecuringscrewhasnotbeenremovedand
you have reason to believe that you have a
complete outside air system, contact your dis-
tributor to have your appliance inspected for
the presence of the complete system. DO NOT
assume that you have this system in place.
1 - Place unit in its normally-operated con-
dition, that is, with the glass enclosure pan-
els in place.
2 - Close all doors and windows in the
room. Turn on all exhaust fans in the house.
3 - Light the appliance.
Outside Air Control Lever with Stop Behind
Securing Screw
4. Always turn off gas to the pilot (millivolt
appliances) and let the unit cool down before
cleaning. Before re-lighting, refer to the light-
ing instructions in this manual. Lighting in-
structions may also be found on the pull out
lighting instruction labels attached to the
gas control valve.
4 - Wait 15 minutes.
5 - To check for venting action, start by
holding a smoke producing device within an
inch of one edge (side edge, not top or
bottom edge) of one glass enclosure panel.
Thesmokeshouldbedrawntowardtheedge
of the glass enclosure panel. Continue the
test by moving the smoke producing device
along the entire length of both side-edges of
the glass door. Repeat the test for all glass
enclosure panels.
5. Always keep the appliance area clear and
free from combustible materials, gasoline and
other flammable liquids.
Outside Air Shutter in the
Closed Position
6. Remember, Millivolt appliances have a con-
tinuous burning pilot flame. Exercise caution
whenusingproductswithcombustiblevapors.
6 - If the smoke is not drawn towards the
edges of the glass door turn off the appli-
anceandcallaqualifiedservicetechnican.
Control Compartment Access Panel
7. Clean the front glass enclosure only when
necessary and when the unit is cool. Wipe
surface with clean, dampened, soft cloth. Fol-
low with dry, soft towel as desired. Take care
not to scratch the glass surface.
Outside Air Control Lever
and Securing Screw Location
(EBST-2, EBPF-2 and EBCR-2 Units Shown)
Figure 4
WARNING: DO NOT USE ABRASIVE
CLEANERS. NEVER CLEAN THE GLASS
WHEN IT IS HOT.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Manual-Reset Safety Limit Switch
B - To access the blocked flue safety switch
when top radiant panel is covered with non-
combustible material:
Maintenance
This appliance is equipped with a manual-
reset blocked flue safety limit switch. Refer to
Figure 5 for its location. If, during appliance
operation, the flame goes out (independently
of theburner on/off wall switch), it maybedue
to the operation of this safety limit switch.
First allow the appliance to cool, then reset
the safety switch by pushing the red reset
button on it.
The appliance and venting system should be
thoroughly inspected before initial use and at
least annually by a qualified service techni-
cian.However,morefrequentperiodicinspec-
tions and cleanings should be performed by
the homeowner. Homeowner must contact a
qualified service technician at once if any
abnormal condition is observed.
Note:Thisprocedureshouldonlybeperformed
by a qualified service technician.
1 -Lower bottom hinged panel on the con-
trol side of the fireplace. Remove the mod-
esty panel and glass enclosure panel as
described on page 8, under "Remove the
front glass enclosure panel as follows:",
Steps 2, 3, 4, 5 and 6.
Refertothemaintenancescheduleformainte-
nance tasks, procedures, periodicity and by
whom they should be performed. Always
verify proper operation of the appliance after
servicing.
A - To access the blocked flue safety switch
when top radiant panel is not covered with
non-combustible material:
2 -Remove the side baffle securing screws
(5) and then remove the baffle.
1 - Lift up and remove top radiant panel/
eyebrow assembly on the control side of
unit.
2 - Reach between the cabinet side and the
firebox side wall and locate the blocked flue
safety switch.
3 -Remove the safety switch bracket secur-
ing screws (2), and pull the switch/bracket
assembly through the side panel slot.
4 -Push the red reset button on the switch.
5 -Reinstall the switch/bracket assembly.
6 -Reinstall the side baffle.
IMPORTANT: TURNOFFGASANDANYELEC-
TRICAL POWER BEFORE SERVICING THE
APPLIANCE.
Front Glass Enclosure Panel, Removal
and Installation.
3 - Push the red reset button on the switch.
7 -Reinstall front glass door.
8 -Raise the bottom hinged panel.
The applilance should then relight and remain
lit. If this does not occur, turn off the appli-
ance and call a qualified service technician.
WARNING: NEVER OPERATE THE APPLI-
ANCE WITHOUT THE GLASS ENCLOSURE
PANELS IN PLACE AND SECURE. DO NOT
OPERATE APPLIANCE WITH FRONT GLASS
CRACKED,BROKENORMISSING. REPLACE-
MENT MUST BE DONE BY A LICENSED OR
QUALIFIED SERVICE TECHNICIAN.
The appliance should then relight and remain
lit. If this does not occur, check unit for a
blocked flue condition.
SAFETY SWITCH LOCATION (EBCL-2 SHOWN)
EBST-2 and EBPF-2 Safety Switch Location Also as Shown; EBCR-2 Location
on Left End of Fireplace, EBBAY Location on The Rear of Fireplace.
These fireplaces are designed to operate only
with the glass enclosure panels properly in-
stalled. Generally the glass enclosure panels
should not be removed except to gain access
to the components within the firebox, and the
appliance may only be operated without the
front glass enclosure panel in place for very
brief periods of time during initial appliance
checkout and adjustment.
FIREBOX SIDE BAFFLE SECURING SCREW
FIREBOX BOX
SIDE WALL
FIREBOX SIDE BAFFLE
MANUALLY-RESET
SAFETY LIMIT SWITCH
Duringthisappliancecheckoutandadjustment
period, apotentialsafetyhazardexists-EXER-
CISE EXTREME CAUTION to prevent the occur-
rence of any burn injuries from the exposed
flames or hot surfaces. Also note, that while the
frontglassenclosurepanel(oranyofthepanels)
is removed, the flame appearance will appear to
be smaller than normal.
WARNING: HANDLE THE GLASS WITH EX-
TREME CARE! TEMPERED GLASS IS SUS-
CEPTIBLE TO DAMAGE (SCRATCHES, FOR
EXAMPLE) – HANDLE GLASS DOOR
(GLASS ENCLOSURE PANEL) GENTLY
WHILE REINSTALLING IT.
SAFETY SWITCH
BRACKET SECURING SCREW
TOP RADIANT PANEL
AND EYEBROW
CABINET SIDE WALL
Figure 5
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance Schedule
Annually (Before the onset of the Burning Season)
Maintenance Task
Accomplishing Person
Procedure
Inspecting/Cleaning Burner, Logs
and Controls
Qualified Service Technician
Inspect valve and ensure it is properly operat-
ing. Check piping for leaks. Vacuum the con-
trol compartment, fireplace logs and burner
area.
Check Flame Patterns and Flame Height
Qualified Service Technician
Qualified Service Technician
Refer to Figure 8 on page 8 and verify that the
flame pattern and height displayed by the
appliance conforms to the picture. Flames
must not impinge on the log set.
Inspecting/Cleaning Pilot Burner and the Two
Main Burners
Refer to Figure 1 on page 8 (SIT) or Figure 12
on page 9 (Honeywell). Remove any surface
build-uponpilotandburnerassembly.Cleanthe
pilot nozzles, ignitor/flame rod and hood with a
soft brush. Ensure the pilot flame engulfs the
flame sensor as shown.
Checking Vent System
Qualified Service Technician
Qualified Service Technician
Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage
or obstruction. Look for any signs of disloca-
tion of the vent components.
Appliance Checkout
Perform the appropriate appliance checkout
procedure detailed in this manual.
Periodically (After the Burning Season)
Maintenance Task
Accomplishing Person
Procedure
Carefully remove logs, vermiculite and black and
grayceramicfiberchunks. Vacuumoutinteriorof
the firebox. Clean firebox walls and log grate.
Replace logs, vermiculite and black and gray ce-
ramic fiber chunks as detailed on page 8.
Cleaning Firebox Interior
Homeowner
Refer to Figure 8 on page 8 and verify that
the flame pattern and height displayed by the
appliance conforms to the picture. Flames
must not impinge on the log set.
Check Flame Patterns and Flame Height
Checking Vent System
Homeowner
Homeowner
Homeowner
Inspect the vent system at the top and at the
base (within the firebox) for signs of block-
age or obstruction. Look for any signs of
dislocation of the vent components.
Clean as necessary following the directions
providedinthismanual. DO NOT TOUCH OR
CLEAN GLASS WHILE IT IS HOT.
Cleaning Glass Enclosure Panels
7
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Reinstallthemodestypanelbyinsertingthe
tongues on the left side of it into the slots on
theleft sidecabinet panel. Swingtheright side
of themodestypanel towardstheunit. Engage
thehookontherightsideofthemodestypanel
with the right side cabinet panel slot. Gently
press the bottom right corner of the modesty
panel to engage the snap-fit feature.
Lower Compartment Door and Hinge
WARNING: DO NOT ATTEMPT TO SUBSTI-
TUTE THE MATERIALS USED ON THESE
DOORS, OR REPLACE CRACKED OR BRO-
KEN GLASS WITH ANY MATERIALS OTHER
THAN THOSE PROVIDED BY THE APPLI-
ANCE MANUFACTURER.
Top Flange
(Glass Enclosure
Panel Frame)
Modesty Panel
Front Glass
Enclosure Panel
THEGLASSDOORSOFTHISAPPLIANCEMUST
ONLYBEREPLACEDASACOMPLETEUNITAS
PROVIDED BY THE MANUFACTURER. DO
NOT ATTEMPT TO REPLACE BROKEN,
CRACKED OR CHIPPED GLASS SEPARATELY.
(The left and right designations used here are
reversed in EBCR-2 applications.)
5. Reinstall the bottom control compartment
access panel by inserting the right side locat-
ing pin into the right side cabinet panel and
thentheleftsidespring-loadedpinintotheleft
side cabinet panel.
Refer to Figure 6 and remove the front glass
enclosure panel as follows:
Glass
Enclosure
Panel
Latch
1. Remove the top bustle, and the top louver
assembly or radiant panel. Then remove the
bottom bustle.
Bottom Vee-flange
(Glass Enclosure
Panel Frame)
6. Reinstall the top and bottom bustle, and the
top louver assembly or radiant panel.
Firebox Floor
EBST-2 SHOWN
2.Openthecontrolcompartmentaccesspanel.
Toopenthecontrolcompartmentaccesspanel,
actuate the spring-loaded magnetic catches
securing the panel, by gently depressing the
outer topcornersof thepanel until thecatches
"pop"thedoorfree,allowingittoswingoutand
down to open.
Burner Adjustments
Figure 6
Note-Theairshutterfortheburnerprimaryair
opening is factory-set. Do not adjust the fac-
tory-set position. The factory-set position is
shown in Figure 7.
5. Locate the latch at the top of the control
compartment. Todisengagethelatchfromthe
bottomvee-flangeoftheglassenclosurepanel,
reach for the handle located towards the back
of the latch and pull the handle down towards
the front of the unit.
3. Remove the bottom control compartment
accesspanelbycompressingthespring-loaded
hinge pin on the left side until it disengages
from the left cabinet corner post hole. Pull the
panel away from the fireplace.
*Air Shutter
Opening
Burner
Venturi
Tube
6. Swing the bottom of the door out and raise
itslightlytoliftthetopflangeofthedoorframe
away from the appliance.
Orifice
To install the front glass enclosure panel,
proceed as follows:
4. Oncethecontrolcompartmentaccesspanel
has been removed, the modesty panel can be
removed as follows: pull the bottom right
corner of the modesty panel out slightly to
disengagethesnap-fitfeature;liftthemodesty
panel by the tab on the panel's right end, pull
the right end of the panel away from the
cabinet and then pull the panel diagonally out
of the left side cabinet panel slots. (In the
above procedure, reverse the words "left" and
"right" for EBCR-2 models).
1. Visually inspect the gasket on the backside
ofthepanel.Thegasketsurfacemustbeclean,
free of irregularities and seated firmly.
*Note - Do Not Adjust the Factory-Set Position.
Eachofthetwoairshutters(oneforeachburner)are
open the amount shown in the table, below.
2. Position the glass enclosure panel in front
ofthefireboxopeningata45degreeangleand
engage the top flange over the lip at the top of
the firebox opening.
MAIN BURNER
FACTORY SHUTTER SETTING
Propane
Gas
inches
(mm)
Natural Gas
inches
(mm)
3. Swing the glass enclosure panel down and
back. Ensure the gasket seats evenly as the
panel draws shut. Engage the Vee-flange at
the bottom of the panel with the latch and then
close the latch to secure the panel.
Remove the modesty panel carefully, so that
none of the wires become loose or discon-
nected.Nowcompleteaccesstothegascontrol
valve and its related controls is attainable.
Models
EBST-2
EBPF-2
EBCR-2
EBCL-2
EBBAY
1/16 (1.5)
5/16 (8)
Figure 7
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Log Placement
WARNING: LOG SET GETS VERY HOT
AND WILL REMAIN HOT UP TO ONE
HOUR AFTER GAS SUPPLY IS TURNED
OFF. HANDLE ONLY WHEN LOG SET IS
COOL. TURN OFF ALL GAS TO THE
APPLIANCE BEFORE INSTALLING THE
GRATE AND LOG SET.
WARNING: THIS APPLIANCE IS NOT DE-
SIGNEDTOBURNWOOD. ANYATTEMPT
TO DO SO COULD CAUSE IRREPARABLE
DAMAGE TO YOUR APPLIANCE AND
PROVE HAZARDOUS TO YOUR SAFETY.
Glowing Embers (Rockwool) Vermiculite Decorative Volcanic Stone
Figure 8
WARNING: THE SIZE AND POSITION OF
THELOGSETWASENGINEEREDTOGIVE
YOUR APPLIANCE A SAFE, RELIABLE
ANDATTRACTIVEFLAMEPATTERN. ANY
ATTEMPT TO USE A DIFFERENT LOG SET
INTHEFIREPLACEWILLVOIDTHEWAR-
RANTY AND WILL RESULT IN INCOM-
PLETE COMBUSTION, SOOTING, AND
POOR FLAME QUALITY.
Note: Iftheburnershavebeenremovedforany
reason, reinstall them as shown in Figure 10.
Outer Log
REAR BURNER
Notch Location
Outer
Log Notch
Location
Riser - Inner Log
Notch Location
Install the vermiculite, decorative volcanic
stone and glowing embers (rockwool):
Spreadvermiculiteonthesimulatedbrickfloor
of the firebox around the burners to simulate
ashes. Maintain a ¹⁄₂ in. gap between the bot-
tom of the horizontal grate section and the top
of the pile of vermiculite. Sprinkle the decora-
tivevolcanicstoneonthevermiculiteasshown
in Figure 8.
Riser - Inner Log
Notch Location
Outer Log
Notch Location
Outer Log
Notch Location
FRONT BURNER
Pilot Assembly
The log set, with one bag of vermiculite, is
packagedinacartonlocatedwithinthefirebox
area. One plastic bag of glowing embers and
one plastic bag of decorative volcanic stone is
located in the bottom compartment. Refer to
the following information and Figures 8 and 9
for detailed placement instructions for the
logs, vermiculite, glowing embers (rockwool)
and decorative volcanic stone. Figure 8 also
shows a typical flame pattern for this particu-
lar appliance.
Place a few dime-sized pieces of rockwool on
the pan burner in front of the burned out area
on both sides of the log set. The pieces of
rookwool may touch one another, but should
not overlap each other.
FIREBOX SUBFLOOR
FRONT OF FIREPLACE
LOG NOTCH LOCATION RELATIVE TO BURNER
Figure 9
Millivolt Appliance Checkout
The pilot flame should be steady, not lifting or
floating. Flame should be blue in color with
traces of orange at the outer edge.
BURNER POSITIONING
Install the unitized log set:
NOTE: INSTALL REAR BURNER FIRST,
THEN FRONT BURNER.
BURNER
PORTS
a - The bottom of the log set is notched to
accommodate the pilot.
BRACKET A
REAR BURNER
The top ³⁄₈" (10 mm) at the pilot generator
(thermopile) and the top ¹⁄₈" min (tip) of the
quick drop out thermocouple should be en-
gulfed in the pilot flame. The flame should
project1"(25mm)beyondthehoodatallthree
ports. See Figure 11.
b - Place the log set so that the four inner
notches on the underside of the log set
fit over the four risers located on the burner
ends. See Figure 9. This procedure is accom-
plished primarily by feel, as the log set masks
the burner risers as it is being installed.
PILOT
BURNER
To light the burner, refer to the lighting in-
structions on pages 14 and 15.
c - As a final check for correct log set place-
ment, check that the four outer notches on the
underside of the log set fit over the burner
tines as indicated in figure 6.
FRONT BURNER
Note: The burners are not identical. Position them so
that the circular burner ports run as shown. Note
especially the vertical run of ports relative to the pilot
burner. Bracket A on the rear burner will interfere
with the pilot burner if an attempt is made to install
the rear burner in the front burner’s position.
Figure 10
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY
Ignitor Rod
Hood
MILLIVOLT
Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced,
it must be replaced with Type AWM 105°C – 18 GA. wire.
Your gas appliance is covered by a limited
twenty year warranty. You will find a copy of
the warranty accompanying this manual.
Please read the warranty to be familiar with its
coverage.
Thermocouple
White
³⁄₈" Min
(9 mm)
Thermopile
Pilot
Retainthismanual. Fileitwithyourotherdocu-
ments for future reference.
Nozzels
Black
Thermopile
Field Wired
Factory Wired
REPLACEMENT PARTS
Figure 11
APPLIANCE-MOUNTED ON/OFF SWITCH
*OPTIONAL WALL-MOUNTED ON/OFF
SWITCH OR OPTIONAL THERMOSTAT
OR OPTIONAL REMOTE RECEIVER
A complete parts list is found at the end of this
manual. Use only parts supplied from the
manufacturer.
Electronic Appliance Checkout
To light the burner, refer to the lighting instruc-
tionsonpage15and16. Ensuretheignitorlights
the pilot. The pilot flame should engulf the flame
sensor as shown in Figure 12.
*Turn the appliance-mounted ON/OFF burner control
switch to the OFF position if an optional
control switch is installed.
Normally, all parts should be ordered through
your Lennox distributor or dealer. Parts will be
shipped at prevailing prices at time of order.
Schematic Representation Only
ELECTRONIC
Electronic Wiring Diagram (Honeywell)
1. If any of the original wire as supplied must be replaced,
1. it must be replaced with Type AWM 105°C – 18 GA.
wire.
3/8 To 1/2 Inch
When ordering repair parts, always give the
following information:
Proper Flame
(9 mm to 13 mm)
Adjustment
2. 120V, 60Hz – Less than 3 amps.
*Leave the ON/OFF switch, which is integral
Pilot
Nozzle
with the gas valve, in the ON position.
*ON/OFF Switch (Integral
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
with Gas Valve)
Outlet Box Green
Ground
Electrode
Gas Valve
Ground Screw
PILOT
ASSEMBLY
G
120
VAC.
BK
W
BK
4. The description of the part.
5. The quantity required.
Flame Rod
R
BL
6. The installation date of the appliance.
Hot Surface
Igniter
G
White Wire
To Opposite
Side
If you encounter any problems or have any
questions concerning the installation or appli-
cation of this system, please contact your dis-
tributor, or Lennox directly:
Figure 12
Junction Box
W
With proper care and maintenance, your appli-
ancewillprovidemanyyearsofenjoyment.Ifyou
should experience any problem, first refer to the
troubleshootingguideinthismanual.Ifproblem
persists, contact your Lennox distributor.
Transf.
120 V.
B
G
Hot side of Outlet
24 V
BL
R
LENNOX HEARTH PRODUCTS
WT
BK
1110 West Taft Avenue
Orange, CA 92865
WT
WIRING DIAGRAMS
LIMIT SWITCH
**OPTIONAL WALL SWITCH
OR OPTIONAL THERMOSTAT
OR OPTIONAL REMOTE
RECEIVER
Wiring diagrams are provided here for refer-
ence purposes only. This information is also
provided on schematics attached directly to
the appliance on a pullout panel located within
the control compartment.
APPLIANCE-MOUNTED ON/OFF SWITCH
**Turn the appliance-mounted ON/OFF burner control switch to
the OFF position if an optional control switch is installed.
Factory Wired
Field Wired
Schematic Representation Only
CAUTION: LABEL ALL WIRES PRIOR TO DIS-
CONNECTION WHEN SERVICING CONTROLS.
WIRINGERRORSCANCAUSEIMPROPERAND
DANGEROUS APPLIANCE OPERATION.
PRODUCT REFERENCE INFORMATION
We recommend that you record the following important information about your fireplace. Please
contactyourLennoxdealerforanyquestionsorconcerns. ForthenumberofyournearestLennox
dealer, please call 800-731-8101
Your Fireplace's Model Number _______________________________________
Your Fireplace's Serial Number ________________________________________
The Date On Which Your Fireplace Was Installed __________________________
The Type of Gas Your Fireplace Uses ___________________________________
Your Dealer's Name_________________________________________________
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY COMPONENTS
Door Frame Kits
A decorative door frame kit is available for
use with these appliances. The DTK is de-
signed to attach directly to the front face of
theapplianceatitsextremeedges. TheDTK
providesapictureframefinishfortheappli-
ance. The door frame kit can be retrofitted
onto previously installed appliances.
Remote Control System (Standard)
H0249
RCL
Standard Remote Control System
(Model RCL)
Door Frame Kits
CATALOG NO. / MODEL NO. AND NUMBER OF SETS
The Model RCL (Standard) Remote Control
System, features a simplistic on/off control
function for the fireplace. This model includes
a hand-held transmitter, a remote receiver with
wall-mount coverplate and all hardware re-
quired to install the unit. The remote receiver
can be wall or hearth mounted.
Polished Brass Finish
Brushed Stainless Finish
Unit
Model
No.
for 24 in. wide for 40 in. wide
for 24 in. wide
for 40 in. wide
Glass Door
Glass Door
Glass Door
Glass Door
88L43
88L45
90L69
90L71
The transmitter has ON and OFF functions that
are activated by pressing either button on the
face of the transmitter. When a button on the
transmitterispressed,asignallightilluminates
briefly to verify that a signal has been sent.
DTK24PB-2
DTK40PB-2
DTK24BS
DTK40BS
EBST-2
EBPF-2
EBCR-2
EBCL-2
-
1
2
2
-
1
2
2
1
2
1
1
1
2
1
1
EBBAY
The Model RCL is designed to operate with all
millivolt ignition systems, as well as electronic
ignition systems. It may be installed with use
for either natural or propane gas appliances.
The RCL offers ease of installation and allows
you to execute on-off commands to the fire-
place effortlessly with one simple motion.
Arch Door Kits
Two types of arch door kits are available for
theMulti-OpenSeries. Bothtypesofkitsare
easy to install and do not require hardware
to attach them to the standard door frame.
These kits can be retrofitted to previously
installed Multi-Open Series appliances. The
decorative arch kits can not be used in
conjunction with the screen panel kit.
The Model RCL comes complete with detailed
operating instructions.
Arch Door Kits - CATALOG NO. / MODEL NO. AND QUANTITY
Polished Brass Finish
Brushed Stainless Finish
Unit
Model
No.
ON/OFF Wall Switch Kit
85L87
FWSK
for 24 in. wide for 40 in. wide
for 24 in. wide
Glass Door
for 40 in. wide
Glass Door
Glass Door
Glass Door
ON/OFF Wall Switch Kit
81L37
81L35
98L71
98L69
ADK24CPB
ADK40CPB
ADK24CBS
ADK40CBS
The ON/OFF wall switch kit may be used to
control the operation of the fireplace burner as
an alternative to the modesty panel mounted
ON-OFF switch. Install the ON/OFF wall switch
in a convenient location near the fireplace.
EBST-2
EBPF-2
EBCR-2
EBCL-2
EBBAY
-
1
2
2
-
1
2
2
1
2
1
1
1
2
1
1
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY COMPONENTS CONTINUED
Charcoal Finish Louver Assembly Kits
(3-piece Top and 3-piece Bottom Assembly)
CATALOG NO. / MODEL NO.
AND NUMBER OF SETS
Charcoal Finish
Unit
Model
No.
for 24 in. wide for 40 in. wide
Glass Door
Glass Door
88L23
88L25
LVR24C-2
LVR40C-2
EBST-2
EBPF-2
EBCR-2
EBCL-2
-
1
2
2
Remote Control System (Deluxe)
H0251
RCL-T
1
2
1
1
Deluxe Remote Control System
(Model RCL-T)
EBBAY
The Model RCL-T (Deluxe) Remote Control
System has all of the features of the standard
system along with an added easy to read LCD
screen which presents access to many en-
hancements, including; battery power level in-
dicator, timer, modeofoperation, thermostatic
display including room temperature in either
metric of English units, flame indicator and
clock. Fully programmable, the Model RCL-T
allows for virtual command over nearly all
operational and temperature variables, using
the hand held remote control transmitter.
Charcoal Finish Louvers Kits
Decorative louvers are available for use with all Multi-Open Series appliances. These louvers
aredesignedtoreplacethestandardradiantpanelsthatareprovidedwiththeappliance.These
kitsincludeacharcoal finishtop3-pieceassemblyandabottom3-pieceassembly. Thesekits
can be retrofitted to previously installed appliances.
PolishedBrassandBrushedStainlessHood
Kits
The Model RCL-T (Deluxe) remote control sys-
tem is installed in the same manner as the
standard system, may be operated with elec-
tronic and millivolt systems with either natural
or propane gas. The RCL-T comes complete
with detailed operating instructions.
Attractive hoods are available in two styles to be
usedontheMulti-OpenSeriesappliances.These
hoods are designed to be fitted to the glass
viewing sides of the appliance. In addition to
providing an aesthetically pleasing appearance
to your appliance installation, the hood reduces
heat effects to decorative mantles and finish
materials located above the fireplace opening.
The hood kit replaces the standard hood that
comes with these appliances and snaps into
place. These kits can be retrofitted to previously
installed appliances.
Hood Kits
CATALOG NO. / MODEL NO. AND NUMBER OF SETS
Polished Brass Finish
Brushed Stainless Finish
Unit
Model
No.
for 24 in. wide for 40 in. wide
for 24 in. wide
Glass Door
for 40 in. wide
Glass Door
Outside Combustion Air Kits
(with duct)
(without duct)
81L87
81L88
FOAK-4
FOAK-4LD
Glass Door
Glass Door
98K28
96K68
88L47
88L50
EB24PB
EB40PB
EB24BS
EB40BS
OutsideAirKitsModelsFOAK-4andFOAK-4LD
EBST-2
EBPF-2
EBCR-2
EBCL-2
-
1
2
2
-
1
2
2
Outside Air kits are available with duct (FOAK-4)
and without duct (FOAK-4LD) for use if outside
combustion air is required or desired. If model
FOAK-4LDisuseditmustbeusedinconjunction
withlocallypurchased,non-combustibleClass1
or Class 0 flexible duct.
1
2
1
1
1
2
1
1
EBBAY
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY COMPONENTS CONTINUED
2-Piece Polished Brass and Brushed
Stainless Louvers Kits
Decorativelouversareavailableforusewithall
Multi-Open Series appliances. These louvers
aredesignedtoreplaceeither themiddlechar-
coal louver of each set or the charcoal louver
ineachsetclosesttotheglassdoor.Thesekits
include two narrow louvers. They provide a
touch of elegance to any Multi-Open Series
appliance. These kits can be retrofitted to
previously installed appliances.
Screen Panel Kit
24 inch Wide Glass Door
40 inch Wide Glass Door
98K74
96K32
HG24
HG40
Screen Panel Kit
Louver Kits (2-piece)
CATALOG NO. / MODEL NO. AND NUMBER OF SETS
An optional screen panel can be installed on the
Multi-Open Series doors. These screen panels
areeasytoinstall. Thesekitscanberetrofittedto
previouslyinstalledappliances.Thescreenpanel
kits can not be used in conjunction with either of
the arch door kits or door frame kits.
Polished Brass Finish
Brushed Stainless Finish
Unit
Model
No.
for 24 in. wide for 40 in. wide for 24 in. wide
for 40 in. wide
Glass Door
Glass Door
Glass Door
Glass Door
96L04
96L06
96L08
96L10
2LVR24PB
2LVR40PB
LVR24BS
LVR40BS
EBST-2
EBPF-2
EBCR-2
EBCL-2
EBBAY
-
1
2
2
-
1
2
2
1
2
1
1
1
2
1
1
Touch-Up Paint (Charcoal) Kit
90L74
TPK-C
Touch-Up Paint Kit
Repairofminorscratchesanddiscolorationof
the appliance charcoal painted cabinet sur-
faces may be accomplished with the touch-up
paint kit.
Polished Brass and Brushed Stainless
Louvers Kits
Decorativelouversareavailableforusewithall
Multi-Open Series appliances. These louvers
are designed to replace the standard radiant
panels that are provided with the appliance.
These kits include a top 3-piece assembly and
a bottom 3-piece assembly. They provide a
touch of elegance to any Multi-Open Series
appliance. These kits can be retrofitted to
previously installed appliances.
Louver Assembly Kits (3-piece Top and 3-piece Bottom Assembly)
Twin-Pane Door Trim Kits
Polished Brass - 40 inch
Brushed Stainless - 40 inch
CATALOG NO. / MODEL NO. AND NUMBER OF SETS
20M83
20M86
TPDK-40PB
TPDK-40BS
Polished Brass Finish
Brushed Stainless Finish
Polished Brass and Brushed Stainless
Twin-Pane Door Trim Kits
Unit
Model
No.
for 24 in. wide for 40 in. wide for 24 in. wide
for 40 in. wide
Glass Door
88L27
LVR24PB-2
Glass Door
88L29
LVR40PB-2
Glass Door
88L31
LVR24BS
Glass Door
88L33
LVR40BS
Two types of twin-pane door trim kits are
available for the Multi-Open Series (polished
brass or bruhed stainless). Both types of kits
are easy to install and do not require hardware
to attach them to the standard glass door
frame. Only the 40 inch glass door frame can
be fitted with these kits. The decorative twin-
pane door trim kits can not be used in
conjunction with the screen panel kit.
EBST-2
EBPF-2
EBCR-2
EBCL-2
EBBAY
-
1
2
2
-
1
2
2
1
2
1
1
1
2
1
1
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This appliance has a pilot which must be lighted with a piezo
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
ignitor. When lighting the pilot, follow these instructions
exactly.
• If your gas supplier cannot be reached, call the fire depart-
ment.
B. BEFORE OPERATING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
do not try to repair it, call a qualified service technician. Force
or attempted repair may result in a fire or an explosion.
WHAT TO DO IF YOU SMELL GAS
• Extinguish any open flame.
• Open windows.
• Do not light any appliance.
• Do not touch any electrical switches.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Access the lower control compartment.
3. Turn remote wall switch to “OFF.”
6. Wait five (5) minutes to clear out any gas. If you then smell gas,
STOP! Follow “B” in the safety information above on this page. If you
do not smell gas, go to the next step.
7. Push in gas control knob slightly and turn counterclockwise
to “PILOT.”
4. Verify main line shut-off valve is open.
8. Push in control knob all the way and hold in. Immediately light the
pilot by triggering the spark ignitor (pushing the button) until pilot
lights. Continue to hold the control knob in for about 1 ¹⁄₂ minutes
after the pilot is lit. Release knob and it will pop back up. Pilot should
remain lit. If it goes out, repeat steps 5 through 8.
5. Push in gas control knob slightly and turn clockwise
to “OFF.”
I N
O U T
• If knob does not pop up when released, stop
and immediately call your service technician
or gas supplier.
I
H
F
F
O
P
I
L
O
L
O
W
T
• If pilot will not stay lit after several
tries, turn the control knob to “OFF”
and call your service technician or
gas supplier.
O
N
P
I
L
T O
9. Turn gas control knob counterclockwise
to “ON.”
Note: Knob cannot be turned from “PILOT” to “OFF”
unless the knob is pushed in slightly. Do not force.
10. Close lower control compartment.
TO TURN OFF GAS TO APPLIANCE
1. Turn remote wall switch “OFF.” The pilot will remain lit for
4. Depress gas control knob slightly and turn clockwise
normal service.
to “OFF.” Do not force.
2. For complete shutdown, turn remote wall switch to “OFF.”
5. Close lower control compartment.
3. Access the lower control compartment.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE
AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE
EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.
A. Cet appareil est muni d’une veilleuse qui doit être allumée avec un
allumeur piézo-électrique. Lorsque vous allumez la veilleuse, suivre
exactement ces instructions.
B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez aucune
odeurdegazautourdel’apareilainsiqueprèsdusol;certainsgaz,étant
plus lourds que l’air, descendent au niveau du sol.
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE ODEUR
DE GAZ:
•
•
Appelezimmédiatementvotrecompagniedegazenutilisantletéléphone
du voisin.
S’il vous est impossible de contacter votre compagnie de gaz, appelez
le service des incendies.
C. N’utilisez que votre main pour manipuler le bouton de réglage du gaz.
N’utilisez jamais d’outils. Si le bouton refuse de tourner ou de bouger,
n’essayez pas de le réparer. Communiquez immédiatement avec un
technicien de service qualifié. Toute tentative pour le forcer ou le
réparer, risquerait de provoquer un incendie ou une explosion.
D. Ne vous servez pas de cet appareil si l’un de ses éléments a été
immergé dans l’eau. Appelez immédiatement un technicien compétent
pour faire inspecter l’appareil et remplacer toute pièce du système de
réglage ou commande du gaz qui a été sous l’eau.
•
•
•
•
•
Éteignez toute flamme visible.
Ouvrez les fenêtres.
N’allumez aucun appareil.
Ne touchez à aucun commutateur électrique.
Ne vous servez d’aucun téléphone dans votre édifice.
INSTRUCTIONS D'ALLUMAGE
1. ARRÊTEZ! Lisez les consignes de sécurité au verso de cette plaque.
2. Ouvrez le compartiment de contrôle du bas.
3. Tournez l’interrupteur mural à la position d’arrêt “OFF”.
4. Assurez-vous que la soupape d’arrêt de la canalisation principale est
ouverte.
8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.
Allumez immédiatement la veilleuse en déclenchant l’allume-gaz à
étincelle (en poussant le bouton) jusqu’à ce que la veilleuse
s’enflamme. Continuez de tenir le bouton de réglage enfoncé
pendant environ 90 secondes après l’allumage de la veilleuse.
Relâchez le bouton et il sortira subitement. La veilleuse devrait
rester allumée. Si elle s’éteint, répétez les étapes 5 à 8
inclusivement.
5. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
le sens des aiguilles d’une montre
jusqu’à la position
d’arrêt “OFF”.
• Si le bouton ne sort pas automatiquement après avoir été relâché,
arrêtez immédiatement et téléphonez
à votre technicien de service ou à
I N
O U T
votre fournisseur de gaz.
H
F
O
P
I
L
• Si la veilleuse refuse de rester
allumée après plusieurs tentatives,
tournez le bouton de réglage jusqu’à
sa position d’arrêt “OFF” et
O
L
W
T
O
N
P
I
L
T O
téléphonez à votre technicien de
service ou à votre fournisseur de gaz.
9. Tournez le bouton de réglage du gaz en sens inverse des aiguilles
Remarque: Il est impossible de tourner le bouton de “PILOT” à “OFF” à
moins qu’il ne soit légèrement enfoncé. Ne le forcez pas.
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous décelez
une odeur de gaz, ARRÊTEZ ! Retournez au point “B” des consignes
de sécurité au verso de cette plaque. Si vous ne remarquez aucune
odeur de gaz, passez à l’étape suivante.
d’une montre
jusqu’à sa position de marche “ON”.
10. Fermez le compartiment de contrôle du bas.
11. Au besoin, rebrancher l’appareil au courant électrique et remettre
l’interrupteur du brûleur principal à la position “ON” ou régler le
thermostat à la température désirée.
7. Enfoncez légèrement le bouton de réglage du gaz et tournez-le en
12. Si l’appareil ne fonctionne pas, suivre les instructions intitulées
“Pour fermer le gaz qui alimente l’appareil” et appeler un
technicien ou le fournisseur de gaz.
sens inverse des aiguilles d’une montre jusqu’à la position de
veilleuse
“PILOT”.
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL
1. Tournez l’interrupteur mural à la position d’arrêt “OFF”. La veilleuse
4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
restera allumée jusqu’au retour du service normal.
le sens des aiguilles d’une montre
jusqu’à la position
d’arrêt “OFF”. Ne forcez pas le bouton.
2. Pour une fermeture complète, tournez l’interrupteur mural à la
position d’arrêt “OFF”.
5. Fermez le compartiment de contrôle du bas.
3. Ouvrez le compartiment de contrôle du bas.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
LIGHTING INSTRUCTIONS — ELECTRONIC
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. When lighting the appliance, follow these instructions
• Immediately call your gas supplier from a neighbor’s
exactly.
phone.
• If your gas supplier cannot be reached, call the fire
B. BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
department.
C. Use only your hand to turn the gas control lever. Never
use tools. If the lever will not turn by hand, do not try to
repair it, call a qualified service technician. Force or
attempted repair may result in a fire or an explosion.
WHAT TO DO IF YOU SMELL GAS
• Extinguish any open flame.
• Open windows.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
• Do not light any appliance.
• Do not touch any electrical switches.
• Do not use any phone in your building.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Turn remote wall switch to “OFF.”
5. Turn the ON/OFF switch to “OFF”. Do not force.
6. Wait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow “B” in the safety information
above on this page. If you do not smell gas, go to the
next step.
3. Open lower control compartment door.
4. Verify main line shut-off valve is open.
7. Turn the ON/OFF switch to “ON”. Do not force.
ON/OFF Switch
8. Turn “ON” all electrical power to appliance (remote wall
or appliance switch).
9. Close lower control compartment door.
TO SHUT OFF
1. Turn off all electrical power to the appliance (remote wall
switch).
Front View
TO TURN OFF GAS TO APPLIANCE
1. For complete shut-down, turn remote wall switch to
3. Turn the ON/OFF switch to “OFF”. Do not force.
4. Close the main line shut-off valve.
“OFF.”
2. Open lower control compartment door.
5. Close lower control compartment door.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTRUCTIONS D’ALLUMAGE — ELECTRONIC
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE
AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU
UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.
A. Lorsquevousallumezl’appareil,suivezexactementcesinstruc-
• Appelezimmédiatementvotrecompagniedegazenutilisant
tions.
le téléphone du voisin.
• S’il vous est impossible de contacter votre compagnie de
B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez
aucune odeur de gaz autour de l’apareil ainsi que près du sol;
certains gaz, étant plus lourds que l’air, descendent au niveau
du sol.
gaz, appelez le service des incendies.
C. N’utilisez que votre main pour manipuler l'interrupteur “ON/
OFF” de la valve à gaz. N’utilisez jamais d’outils. Si
l’interrupteur ne bouge pas manuellement, n’essayez pas de le
réparer. Communiquez immèdiatement avec un technicien de
service qualifié. Toute tentative pour forcer l’interrupteur ou le
réparer, risquerait de provoquer un incendie ou une explosion.
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE
ODEUR DE GAZ
• Éteignez toute flamme visible.
• Ouvrez les fenêtres.
D. Ne vous servez pas de cet appareil si l’un de ses éléments a été
immergé dans l’eau. Appelez immédiatement un technicien
compétent pour faire inspecter l’appareil et remplacer toute
piècedusystèmederéglageoucommandedugazquiaétésous
l’eau.
• N’allumez aucun appareil.
• Ne touchez à aucun commutateur électrique.
• Ne vous servez d’aucun téléphone dans votre édifice.
INSTRUCTIONS D’ALLUMAGE
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous
décelez une odeur de gaz ARRÊTEZ ! Retournez au point “B” des
consignes de sécurité au verso de cette plaque. Si vous ne
remarquez aucune odeur de gaz, passez à l’étape suivante.
1. ARRÊTEZ ! Lisez les consignes de sécurité au verso de cette
plaque.
2. Tournez l’interrupteur mural à la position d’arrêt “OFF”.
7. Tournezlamanettederéglagedugazjusqu’àlapositiondemarche
3. Ouvrez la porte du compartiment de contrôle du bas.
“ON”. Ne la forcez pas.
4. Assurez-vousquelasoupaped’arrêtdelacanalisationprincipale
8. Ouvrez le courant électrique (“ON”) qui alimente l’appareil
est ouverte.
(interrupteur mural ou l'appareil).
9. Fermez la porte du compartiment de contrôle du bas.
5. Tournezlamanettederéglagedugazàlapositiond’arrêt“OFF”.
10. Au besoin, rebrancher l’apareil au courant électrique et
remettre l’interrupteur principal du brûleur à la position “ON”
ou régler le thermostat à la température désirée.
Interrupteur
ON/OFF
11. Si l’appareil ne se met pas en marche, suivre les instructions
intitulées “Pour fermer le gaz qui alimente l’appareil” et appeler
un technicien ou le fournisseur de gaz.
POUR ÉTEINDRE L’APPAREIL
1. Coupeztoutlecourantélectriquequialimentel’appareil(interrupteur
Vue de face
mural).
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL
1. Pour une fermeture complète, tournez l’interrupteur mural à la
3. Tournezlamanettederéglagedugazàlapositiond’arrêt“OFF”.
position d’arrêt “OFF”.
Ne la forcez pas.
2. Ouvrez la porte du compartiment de contrôle du bas.
4. Fermez la soupape d’arrêt de la canalisation principale.
5. Fermez la porte du compartiment de contrôle du bas.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM
Note: Before troubleshooting, make sure that the appliance main line gas shut-off valve and the gas control valve are in the "OPEN"
position and the burner ON/OFF switch is in the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
POSSIBLE CAUSES
SYMPTOM
CORRECTIVE ACTION
A. Defective ignitor
1. Spark ignitor will not light
pilot after repeated
Check for spark at electrode and pilot; if no spark and
electrode wire is properly connected, replace ignitor.
(no spark at electrode).
triggering of ignitor button.
Using a match, light pilot. If pilot lights, turn off pilot and
trigger the ignitor button again. If pilot lights, an improper gas
mixture caused the bad lighting and a longer purge period is
recommended. If pilot will not light – check gap at electrode
and pilot – should be ¹⁄₈" to have a strong spark. If gap
measures ¹⁄₈", replace pilot (Figure 11 on page 8).
B. Defective or misaligned electrode
at pilot (spark at electrode).
C. Gas supply pressure errant.
Check inlet gas pressure. It should be within the limits as
marked on the rating plate.
D. Pilot orifice plugged.
Clean or replace pilot orifice.
A. Defective pilot generator
(thermocouple).
2. Pilot will not stay lit after
carefully following the
lighting instructions.
Check pilot flame, it must impinge on thermocouple (Figure
11 on page 8) Clean and/or adjust pilot for maximum flame
impingement on thermocouple. Ensure that the connection
between the valve and thermocouple are tight and secure.
A. Limit Switch defective.
Isolatethe“limit” switch. Disconnectthewiresfromthe“ON/
OFF” switchandthevalve(labelwiresforreattachment).Test
forcontinuitywithamultimeter. Ifcontinuityisnotindicated,
switch is defective and must be replaced.
3. Pilot burning, no gas to
burner, Valve knob “ON,”
Wall Switch “ON.”
B. Wall switch or wires defective.
Check wall switch and wires for proper connections. Jumper
wire across terminals at wall switch, if burner comes on,
replacedefectivewallswitch.Ifokay,jumperwiresacrosswall
switch wires at valve, if burner comes on, wires are faulty or
connections are bad.
C. Thermopile may not be generating
Checkthermopilewithmillivoltmeter.Takereadingatthermo-
pile terminals of gas valve. Should read 325 millivolts mini-
mum with optional wall switch “OFF.” Replace faulty thermo-
pile if reading is below specified minimum.
sufficient millivoltage.
Check burner orifice for stoppage and remove.
D. Plugged burner orifice.
A. Pilot flame may be too low or
blowing (high) causing the pilot/
valve safety to drop out.
Clean and/or adjust pilot flame for maximum flame impinge-
ment on thermocouple (Figure 11 on page 8).
4. Frequent pilot/burner outage
problem.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM
Note: Before troubleshooting, make sure that the appliance main line gas shut-off valve and the gas control valve are in the "OPEN"
position and the burner ON/OFF switch is in the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE ACTION
1. Burner will not light.
A. Faulty Valve System.
See Below.
B. “OFF/ON” or wall switch
Disconnect the two black wires from the wire nuts. Test switch(s) for
continuity with a multimeter. If continuity is not indicated, switch(s) is
defective and must be replaced.
defective.
Note: Before replacing “OFF/ON” switch, be sure to check wiring for loose
connections or broken wires and repair as needed.
2. Burners come “ON” but
A. Burner orifice plugged.
Check main burner orifice(s) for stoppage. Clean or replace.
Check vent system for obstructions.
go “OFF.”
B. Obstructed vent system.
START
CHECK
• Check For Proper Voltage At Control Harness
(See Insert A). Voltage Should Be 24V
Between Thermostat Or Pressure Switch
• Turn Off Gas Supply
• Line Voltage Power
• Low Voltage Transformer
• Limit Controller
• Thermostat
NO
• Assure Valve Switch Is In ON Position
• Disconnect Control Harness
• Set Thermostat To Call For Heat
And 24V Common And 24V Hot.
2
• Wiring
YES
• Plug Control Harness Into Valve. Wait For
Internal Check Delay.
• With Pilot Burner Cable Connected, Measure
Voltage At Valve HSI Element Output. 24V
Nominal. (See Insert B)
NO
NO
• Igniter Warms Up And Glows Red.
• Replace Valve.
Insert A
End View Of
Control Harness
Connector
1
2
24 Volt Hot
YES
24 Volt
Common
1
YES
• Replace Igniter/Flame Rod Assembly.
YES
24 Volt
Switched
NO
NO
• Check That Pilot Gas Is Flowing. Wait To
Assure Plot Gas Tubing Is Purged. Recycle
Call For Heat If Necessary.
• Replace Valve.
• Turn On Gas Supply. • Pilot Burner Lights.
Check For Damaged Or Missing Terminals
In Connector
YES
• Measure Voltage Between 24V Hot And 24V Common
Leads To Valve Control. Must Measure At Least 19.5
VAC With Igniter Powered (See Insert A). To Identify
Proper Lead, This Check Must Be Done With The
Valve Control Connected And Igniter Powered.
NO
• Check Transformer And
Line Volt Supply.
Insert B
YES
Igniter Terminals
YES
• Replace Pilot Assembly.
• Check That Pilot Flame Makes Good Contact With
Pilot Burner Flame Rod.
NO
• Check For Good Electrical Connection Through The
Pilot Tubing.
• Main Valve Opens And Main Burner Lights.
YES
• If Both Of The Above Are Good, Replace Igniter/Flame
Rod Assembly.
YES
• Cycle Thermostat Off And Back On.
• System Is Okay.
Igniter Will Cycle Off And Back On Once During
When Measured Voltage At Connections, Use
Care To Assure Terminals Are Not Damaged.
NO
1
2
• Main Burner Lights.
• Replace Valve.
The 90 Second Ignition Trial. All Voltage
Measurements Must Be Taken While The Igniter
Is Powered.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS
GAS CONTROLS — SIT MILLIVOLT
Natural
Propane
Part No.
No.
DESCRIPTION
Part No.
43K0701
10K8601
69L1701
60J7901
74L5701
74L5601
74L5801
24M6501
Qty.
1
Qty.
1
30.
31.
32.
33.
34.
35.
36.
37.
Gas Valve - SIT
Piezo Igniter
88J5301
10K8601
69L1801
60J7901
74L5701
74L5601
74L5801
24M6501
1
1
Pilot Assembly
Pilot Generator
Thermocouple
Pilot Tube
1
1
1
1
1
1
1
1
Electrode And Cable
Sticker (Modesty Panel)
1
1
1
1
GAS CONTROLS — HONEYWELL ELECTRONIC
Natural
Propane
Part No.
No.
DESCRIPTION
Part No.
62L1801
62L1401
42J3201
87L54
Qty.
1
Qty.
1
40.
41.
42.
43.
44.
45.
Gas Valve - Honeywell
Pilot Assembly
62L1901
62L1501
42J3201
87L54
1
1
Transformer
1
1
Ignitor Assembly (Kit)
Sticker (Modesty Panel)
Pilot Tube
1
1
69L5001
LB-97487A
1
69L5001
LB-97487A
1
1
1
GAS ORIFICES — SIT AND HONEYWELL SYSTEMS
Natural
Part No.
Propane
No. DESCRIPTION
Qty.
2
Part No.
19L5201
67L5801
Qty.
2
50. Gas Orifice - Main EBST-2/EBPF-2/EBBAY
51. Gas Orifice - Main EBCR-2/EBCL-2
60J8001
99K7401
2
2
20
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS LIST
Natural and Propane
Qty. Qty. Qty.
EBST-2 EBPF-2 EBCL-2 EBCR-2 EBBAY
No. DESCRIPTION
Part No.
Qty.
Qty.
1a Upper Radiant, charcoal - 24 in.
1b Upper Radiant, charcoal - 40 in.
2a Hood, Charcoal - 24 in.
LB-91885EY none
LB-91885CY
LB-91941EY none
1
2
1
1
1
1
2
1
2
1
1
1
2
2b Hood, Charcoal - 40 in.
LB-91941CY
LB-96790E
LB-96790C
LB-97541A
LB-97542A
LB-92496E
LB-92496C
LB-92649E
LB-92649C
12L1501
2
2
1
1
1
3a Upper Bustle, charcoal - 24 in.
3b Upper Bustle, charcoal - 40 in.
4a Glass Enclosure Assembly - 24 in.
4b Glass Enclosure Assembly - 40 in.
5a Lower Bustle, charcoal - 24 in.
5b Lower Bustle, charcoal - 40 in.
6a Lower Radiant Assembly, charcoal - 24 in.
6b Lower Radiant Assembly, charcoal - 40 in.
none
1
1
1
2
2
2
1
1
1
none
1
1
1
2
2
2
1
1
1
none
1
1
1
2
2
none
2
2
1
1
1
1
1
1
2
2
1
1
1
7
8
Nameplate (Brand)
Log Set
2
2
1
1
1
74L6201
1
1
1
1
1
9a Bag of Vermiculite
24M4801
88L53
2
2
2
2
2
9b Bag of Embers - (Rockwool)
9c Bag of Decorative Volcanic Stone
10 Magnet, Radiant Panel
1
1
1
1
1
80L42
1
1
1
1
1
43K0101
2
4
3
3
5
11a
11b
Rear
Front
LB-97437A
LB-97437B
43K8501
1
1
1
1
1
Main Burner Set
1
1
1
1
1
12 Gasket, Venturi Tube Mounting (per burner)
1
1
1
1
1
13a
13b
ST, PF, CL
CR
LB-97069A
LB-97069B
69L2101
1
1
1
none
1
1
Modesty Panel
none
2
none
2
none
1
none
1
14 Latch, Glass Enclosure Panel
15 Magnet, Latch, Spring-Loaded
16 Switch, Rocker
1
69L3101
4
4
2
2
1
27K3001
1
1
1
1
1
17 Limit Switch
62L1601
1
1
1
1
1
18 Flex Gas Line Connector
43K3301
1
1
1
1
1
21
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS
Note: - EBPF-2 Shown - see the tables on pages 20 and 21 for replacement parts
applicable to EBST-2, EBCR-2, EBCL-2 and EBBAY fireplaces.
9a
9b
1a
2a
3a
8
Cabinet Corner
Post Location
10
4a
5a
6a
17
Inside
Location
12
12
11a
1b
2b
3b
11b
Rear Burner
15
Front Burner
4b
43
14
41
50
51
15
36
5b
6b
30
18
45
33
34
32
40
16
31
35
7
37 44
13a 13b
42
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES:
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design,
materials, specifications, prices and also to discontinue colors, styles and products. Consult your
local distributor for fireplace code information.
Printed in U.S.A. © 2002 by LENNOX HEARTH PRODUCTS
P/N 875,012M REV. D 05/2004
1110 West Taft Avenue • Orange, CA 92865
Download from Www.Somanuals.com. All Manuals Search And Download.
|