CARE AND OPERATION INSTRUCTIONS
EDV Direct-Vent
Gas Fireplaces
™
P/N 875022M Rev. F 01/2011
MODELS
This manual is part of a set of two supporting this product.
Refer to P/N 850018M for Installation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 875022CF.
MILLIVOLT:
ELECTRONIC:
EDVSTNM-B
EDVCRNM-B
EDVCRPM-B
EDVCLNM-B
EDVCLPM-B
EDVSTNE-B
EDVPFNE-B
EDVCRNE-B
EDVCLNE-B
EDVSTPM-B
EDVPFNM-B
EDVPFPM-B
WHAT'S INSIDE
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer (Protects Against Burns) . . . . . . . . . . . . . 2
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . 5
Portland
US
OTL Report No. 116-F-04-5
[EN FRANÇAIS] L’information de sûreté importante . . . . . . . . . . . . 3–4
Apposition des mises en garde relatives à la sécurité d’utilisation . . . 5
[EN ESPAÑOL] Información importante de seguridad. . . . . . . . . . . . 3–4
Colocación de advertencias de seguridad en operación . . . . . . . . . . 5
▪
▪
▪
▪
▪
Wait...
DON’T
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
THROW
P
R
O
T
E
C
T
S
IT AWAY!
This manual contains
important operating
and safety
A
G
A
I
N
S
T
B
U
▪
R
N
S
▪
CONSOMMATEUR : Conservez cette notice pour consultation ultérieure.
information.
/
/
WARNING AVERTISSEMENT AVISO
• HOT GLASS WILL CAUSE
BURNS.
• UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
• DO NOT TOUCH GLASS
UNTIL COOLED.
TOCAR EL VIDRIO CALIENTE.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
• NE PERMETTEZ JAMAIS À UN ENFANT • LOS NIÑOS DEBEN NUNCA
DE TOUCHER LA SURFACE VITRÉE.
TOCAR EL VIDRIO.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
-
vapors and liquids in the vicinity of this or any other
appliance.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
•
department.
- Installation and service must be performed by a
Download from Www.Somanuals.com. All Manuals Search And Download.
[FRENCH]
[SPANISH]
La sécurité et
votre foyer
Seguridad y
su chimenea
Toutes les parties de votre foyer
Lennox Hearth Products deviennent
EXTRÊMEMENT CHAUDES !
¡Todas las partes de la chimenea
Lennox Hearth Products se ponen
MUY CALIENTES!
Afin d'éviter de vous brûler gravement ou de
vous blesser, installez une grille ou une barrière
physique pour empêcher tout contact direct
avec la vitre.
Instale una malla o barrera física para evitar
el contacto directo con el vidrio y prevenir
las quemaduras y lesiones graves.
Ver los detalles a la izquierda para ordenar
un Lennox® SAFETY GUARD GRATIS
para su chimenea.
Pour commander un PANNEAU DE PROTECTION
Lennox® GRATUIT pour votre foyer, consultez
les détails dans la partie gauche.
Siga las instrucciones de seguridad a
continuación y asegúrese de que todos
en su hogar sepan acerca de este peligro
de quemadura:
Suivez les instructions de sécurité ci-dessous
et veillez à ce que tous les membres de votre
famille soient conscients du danger de brûlure
encouru :
• ¡Las superficies de la chimenea se ponen
• Les surfaces de votre foyer deviennent
MUY CALIENTES!
EXTRÊMEMENT CHAUDES !
• El vidrio delante de la chimenea alcanza
temperaturas EXTREMADAMENTE ALTAS y
puede causar quemaduras graves si se toca.
• La vitre située à l'avant du foyer
atteint des températures
EXTRÊMEMENT ÉLEVÉES et peut causer
de graves blessures en cas de contact.
• Mantenga a los niños alejados de la
chimenea en funcionamiento. Supervise
en forma cercana a los niños en cualquier
cuarto donde haya una chimenea
funcionando para impedir el contacto
con el vidrio.
• Tenez les enfants à l'écart du foyer lorsqu'il
fonctionne. Surveillez attentivement
les enfants dans les pièces où un foyer
est utilisé afin d'éviter qu'ils ne soient
en contact avec la vitre.
• Mantenga la ropa, mobiliario, gasolina
y otros líquidos inflamables alejados
de la chimenea.
• Tenez tous les vêtements, les
meubles, l'essence et tout autre
liquide inflammable à l'écart du foyer.
• Aún después de haber apagado el gas,
las superficies de la chimenea permanecen
extremadamente calientes.
• Même après fermeture du gaz, les surfaces
du foyer restent extrêmement chaudes.
Veillez à coller les Étiquettes de mise en garde
relatives à la sécurité d'utilisation à l'endroit
où vous utilisez le foyer, pour rappeler à tous les
utilisateurs les dangers liés aux températures
élevées (voir page 5).
Asegúrese de colocar las Etiquetas de
advertencia de seguridad de operación en
el lugar donde enciende la chimenea, para
que todos recuerden los peligros asociados
con las altas temperaturas (ver la página 5).
Lisez la section Informations importantes
Lea la Información importante de seguridad
relatives à la sécurité, page 4.
en la página 4.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Information
L'information de sûreté importante
1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal
en verre n’est pas en place, est craqué ou brisé. Confiez le
remplacement du panneau à un technicien agréé
1. WARNING: Do not operate appliance with the glass front
removed, cracked or broken. Replacement of the glass
should be done by a licensed or qualified service person .
2. Ne pas utiliser cet appareil s’il a été plongé, même partiellement,
dans l’eau. Appeler un technicien qualifié pour inspecter
l’appareil et remplacer toute partie du système de commande
et toute commande qui a été plongée dans l’eau.
2. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
3. En raison des températures élevées, l’appareil devrait être
installé dans un endroit où il y a peu de circulation et loin du
mobilier et des tentures.
3. Due to high temperatures, the appliance should be located
out of traffic and away from furniture and draperies.
4. Les enfants et les adultes devraient être informés des dangers
que posent les températures de surface élevées et se tenir à
distance afin d’éviter des brûlures ou que leurs vêtements ne
s’enflamment.
5. On ne devrait pas placer de vêtements ni d’autres matières
inflammables sur l’appareil ni à proximité.
4. Children and adults should be alerted to the hazards of
high surface temperature and should stay away to avoid
burns or clothing ignition.
5. Clothing or other flammable material should not be placed
on or near the appliance.
6. Les jeunes enfants devraient être surveillés étroitement lorsqu’ils
se trouvent dans la même pièce que l’appareil. Les tout petits,
les jeunes enfants ou les adultes peuvent subir des brûlures s’ils
viennent en contact avec la surface chaude. Il est recommandé
d’installer une barrière physique si des personnes à risques
habitent la maison. Pour empêcher l’accès à un foyer ou à un
poêle, installez une barrière de sécurité ; cette mesure empêchera
les tout petits, les jeunes enfants et toute autre personne à risque
d’avoir accès à la pièce et aux surfaces chaudes.
6. Young children should be carefully supervised when they
are in the same room as the appliance. Toddlers, young
children, and others may be susceptible to accidental
contact burns. A physical barrier is recommended if there
are at-risk individuals in the house. To restrict access to a
fireplace or stove, install an adjustable safety gate to keep
toddlers, young children, and other at-risk individuals out
of the room and away from hot surfaces.
7. Any safety screen or guard removed for servicing an
appliance must be replaced prior to operating the
appliance.
7. Tout écran ou protecteur retiré pour permettre l’entretien de
l’appareil doit être remis en place avant de mettre l’appareil en
marche.
8. L’installation et la réparation devrait être confiées à un technicien
qualifié. L’appareil devrait faire l’objet d’une inspection par un
technicien professionnel avant d’être utilisé et au moins une
fois l’an par la suite. Des nettoyages plus fréquents peuvent
être nécessaires si les tapis, la literie, et cetera produisent
une quantité importante de poussière. Il est essentiel que les
compartiments abritant les commandes, les brûleurs et les
conduits de circulation d’air de l’appareil soient tenus propres.
Voyez les instructions d’entretien à la page 10.
8. Installation and repair should be done by a qualified
service person. The appliance should be inspected
before use and at least annually by a professional service
person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding material, et cetera.
It is imperative that control compartments, burners, and
circulating air passageways of the appliance be kept
clean. See maintenance instructions on page 10.
[SPANISH]
6. Se debe supervisar de cerca a los niños cuando estén en el mismo
cuarto que el artefacto. Los niños pequeños, los jóvenes y otras
personas pueden ser susceptibles a quemaduras por contacto
accidental. Se recomienda instalar una barrera física si hay
personas en riesgo en la casa. Para restringir el acceso a una
chimenea o estufa, instale una puerta de seguridad ajustable
para mantener a los niños pequeños, jóvenes y otras personas
en riesgo fuera del cuarto y lejos de las superficies calientes.
Información importante de seguridad
1. ADVERTENCIA: No opere el artefacto con el frente de vidrio quitado,
agrietado o roto. Un técnico de servicio licenciado o capacitado
debe reemplazar el vidrio.
2. No use este artefacto si alguna de sus partes ha estado bajo agua.
Llame de inmediato a un técnico de servicio calificado para que
inspeccione el artefacto y reemplace cualquier parte del sistema
de control y cualquier control de gas que haya estado bajo agua.
7. Cualquier malla o resguardo de seguridad quitado para dar servicio
a un artefacto, debe reinstalarse antes de operar el artefacto.
3. Debido a las altas temperaturas, el artefacto debe situarse fuera
de las áreas de tráfico y lejos del mobiliario y cortinas.
8. Una persona de servicio competente debe realizar la instalación y
reparación. Una persona de servicio profesional debe inspeccionar
el artefacto antes de usar al menos una vez por año. Se puede
requerir limpieza más frecuente debido a la pelusa excesiva
del alfombrado, del material de cobijas, etc. Es imprescindible
mantener limpios los compartimientos de control, los quemadores
y los pasajes de circulación del aire del artefacto. Ver las
instrucciones de mantenimiento en la página 10.
4. Se debe alertar a los niños y adultos sobre los peligros de
las altas temperaturas en la superficie y que se mantengan
alejados para evitar quemaduras o ignición de la ropa.
5. No debe colocarse ropa u otros materiales inflamables
sobre y cerca del artefacto.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS
ATTACHING SAFETY-IN-OPERATION
WARNINGS
APPOSITION DES MISES EN GARDE RELATIVES
à LA SÉCURITÉ D’UTILISATION
COLOCACIóN DE ADVERTENCIAS DE
SEGURIDAD EN OPERACIóN
Yourfireplacehasbeenfurnishedwithsafetyinstruc- Votrefoyeraétélivréavecdesétiquettesdesécuritéqui Su chimenea incluye etiquetas de instrucciones
tion labels that are to be affixed to the operation and doivent être collées à côté des dispositifs de contrôle de seguridad que deben colocarse en el punto de
control point of the fireplace. A safety instruction du foyer. Une étiquette de sécurité doit être collée sur operación y control de la chimenea. Se debe colocar
labelshouldbeaffixedtothewallswitchplatewhere la plaque de l’interrupteur contrôlant l’allumage du una etiqueta de instrucciones de seguridad en la placa
the fireplace is turned on and off (See Figure A) or foyer (voir Figure A) ou sur le thermostat mural (voir del interruptor de pared desde el cual se enciende y se
wall thermostat (See Figure B) and if used on the Figure B) et, le cas échéant, sur le boîtier de la télé- apaga la chimenea (ver la Figura A) o en el termostato
remote control handheld transmitter (Figure C). commande(FigureC). Lesmisesengardeauraientdû de pared (ver la Figura B)y en el transmisor de control
The warnings should already have been put in place êtrecolléesaumomentdel’installationinitialedufoyer. remoto (Figura C)siseusa.Lasadvertenciasyadeben
when the fireplace initial set-up was completed. Si ce n’est pas le cas, prenez les étiquettes adhésives haberse colocado cuando se completó la instalación
If they are not affixed at these spots, locate the multilingues fournies avec ces instructions et procédez inicial de la chimenea. Si no están colocadas en estos
multi-lingual adhesive labels provided with these comme suit:
lugares,encuentrelasetiquetasadhesivasmultilingües
instructions and proceed as follows:
1. Repérez l’interrupteur ou le thermostat mural proporcionadas con estas instrucciones y prosiga de
qui contrôle le foyer (vérifiez que l’interrupteur la siguiente manera:
1. Locate the wall switch or wall thermostat that
controlsthefireplace(verifytheswitchoperates
the fireplace by turning it on and off). Clean the
wall switch plate or wall thermostat thoroughly
to remove any dust and oils. Affix the label to
the surface of the plate of the wall switch that
controls the fireplace (Figure A) or the wall
thermostat (Figure B). Choose the language
primarily spoken in the home.
contrôle le fonctionnement du foyer en le faisant 1. Identifique el interruptor o el termostato de pared
basculerdeMarcheàArrêt,etvice-versa). Nettoyez
soigneusement la plaque murale de l’interrupteur
ou le thermostat mural pour éliminer la poussière
et les traces de graisse ou d’huile. Collez l’étiquette
sur la surface de la plaque de l’interrupteur mural
qui contrôle le foyer (Figure A) ou du thermostat
mural (Figure B). Choisissez la langue qui est
principalement parlée dans la résidence du
propriétaire.
quecontrolalachimenea(verifiquequeelinterruptor
opera la chimenea encendiéndola y apagándola).
Limpiebienlaplacadelinterruptoroeltermostatode
pared para quitar el polvo y aceite. Pegue la etiqueta
enlasuperficiedelaplacadelinterruptorquecontrola
la chimenea (Figura A) o en el termostato de pared
(Figura B). Seleccione el idioma que más se habla
en la casa.
2. Ifaremotecontrolisusedtocontrolthefireplace,
locate the transmitter and clean it thoroughly
2. Si se usa un control remoto para controlar la
chimenea, encuentre el transmisor y límpielo bien
para quitar el polvo y aceite. Pegue la etiqueta en la
superficie del transmisor (Figura C). Seleccione el
idioma que más se habla en la casa.
to remove any dust and oils. Affix the label to 2. Si une télécommande est utilisée pour contrôler
the surface of handheld transmitter (Figure C).
Choose the language primarily spoken in the
home.
le foyer, nettoyez la soigneusement pour éliminer
la poussière et les traces de graisse ou d’huile.
Collez l’étiquette sur le boîtier de la télécommande
3. If you are unable to locate the labels, please call
LennoxHearthProductsoryournearestLennox
(Figure C). Choisissez la langue qui est principale- 3. Si no puede encontrar las etiquetas, sírvase llamar
ment parlée dans la résidence du propriétaire.
a Lennox Hearth Products o al distribuidor de
Lennox Hearth Products más cercano para recibir
etiquetasdeinstruccionesdeseguridadadicionales
gratuitas.
Hearth Products dealer to receive additional 3. Si vous ne trouvez pas les étiquettes, veuillez
safety instruction labels free of charge.
appeler Lennox Hearth Products ou votre distribu-
teur Lennox Hearth Products local pour recevoir
gratuitement des étiquettes supplémentaires.
Cat. No. H8024 Replacement Label Kit
Juego de etiquetas de repuesto - Nº de cat. H8024
LENNOX HEARTH PRODUCTS
1-800-9-LENNOX
Étiquettes de remplacement, n° cat. H8024
LENNOX HEARTH PRODUCTS
1-800-9-LENNOX
LENNOX HEARTH PRODUCTS
1-800-9-LENNOX
Note: English is red text on clear label. French and
Spanish are white text on black label.
Nota: La etiqueta en inglés es transparente con texto
rojo. Las etiquetas en francés y español son negras
con texto blanco.
Remarque : Le texte anglais est rouge sur un support
transparent. Le texte français et espagnol est blanc
sur un support noir.
SAFETY LABEL
DIAGRAMS
DIAGRAMMES DES ÉTIQUETTES
DE SÉCURITÉ
DIAGRAMAS DE ETIQUETAS
DE SEGURIDAD
Figure C
Figure B
Figure A
5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
These appliances are designed to
operate on natural gas or propane
gas only. The use of other fuels or
combinations of fuels will degrade the
performance of this system and may be
dangerous.
INSTALLATION, SERVICE,
AND MAINTENANCE
General Information
The fireplace models covered in this manual
aredirect-ventsealedcombustiongasfireplace
heaters designed for residential application.
These direct-vent appliances operate with the
combustion chamber completely isolated from
the indoor environment.
IMPORTANT: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this manual.
For assistance or additional information,
consult a qualified installer, service
agency or the gas supplier.
Provide adequate clearances around
air openings and adequate accessibility
clearance for service and proper
operation. Never obstruct the front
openings of the appliance.
All air for combustion is brought in from the
outside and exhaust gases are vented through
the same direct-vent, co-axial (intake/exhaust)
vent system.
Only trim kit(s) supplied by the
manufacturer shall be used in the
installation of this appliance.
Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control that
has been under water.
The Millivolt appliances have a millivolt gas
control valve with piezo ignition system. If any
optional accessories which require electrical
power are being installed, the electrical power
must be provided at the time of appliance in-
stallation.
Draft relief openings must not be
covered or blocked.
These appliances must not be
connected to a chimney or flue serving a
separate solid fuel burning appliance.
WARRANTY
The Electronic appliances are designed to
operate on either natural or propane gas. An
electronic intermittent pilot system provides
safe, efficient operation. External electrical
power is required to operate these units.
Any change to this appliance and/or
its operating controls is dangerous.
Improper installation or use of this
appliance can cause serious injury or
death from fire, burns, explosion or
carbon monoxide poisoning.
Failure to comply with the installation
and operating instructions provided
will result in an improperly installed
and operating appliance, voiding its
warranty.
These appliances comply with National Safety
StandardsandaretestedandlistedbyOMNI-Test
Laboratories, Inc. (Report No. 116-F-04-5) to
ANSIZZ21.88(inCanada,CSA-2.33),andCAN/
CGA-2.17-M91 in both USA and Canada, as
vented gas fireplace heaters.
Do not attempt to alter or modify the
construction of the appliance or its
components. Any modification or
alteration may void the warranty,
certification, and listings of this unit.
Carbon Monoxide Poisoning: Early
signs of carbon monoxide poisoning
are similar to the flu with headaches,
dizziness and/or nausea. If you
have these signs, obtain fresh air
immediately. Turn off the gas supply to
the appliance and have it serviced by
a qualified professional, as it may not
be operating correctly. Some people
are more affected by carbon monoxide
than others, including pregnant women,
people with heart or lung disease or
anemia, those under the influence of
alcohol, and those at high altitudes.
The Installation must conform to local codes
or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA
54-latestedition,ortheNaturalGasandPropane
Installation Code, CAN/CSA B149.1-latest edi-
tion. The appliance, when installed, must be
electrically grounded in accordance with local
codes or, in the absence of local codes, the
latest edition of the National Electrical Code,
ANSI/NFPA70, ortheCanadianElectricalCode,
CSA C22.1 - latest editions.
Turn off gas and electrical power to the
fireplace and allow it to cool before
cleaning or servicing the appliance.
Theventterminationishotwhileinopera-
tion and for a period of time following the
use of the fireplace. To prevent contact
withhotsurfaces,werecommendtheuse
of a termination guard.
OPERATION
Do not operate appliance with the glass
front removed, cracked, or broken.
Thesefireplacesaredesignedassupple-
mentalheaters.Therefore,itisadvisable
to have an alternate primary heat source
when installed in a dwelling.
These fireplaces are vented gas
appliances. Do not burn wood or other
material in these appliances.
This appliance is only for use with the
type of gas indicated on rating plate.
This appliance is not convertible for use
with other gases, unless a certified kit is
used.
These appliances must not be connected
to a chimney or flue serving a separate
solid fuel burning appliance.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
BTU Input
Deration - At higher elevations, the amount
of BTU fuel value delivered must be reduced
by either using gas that has been derated by
the gas company or by changing the burner
orifice to a smaller size as regulated by the
local authorities having jurisdiction and by the
(USA) National Fuel Gas Code NFPA 54/ANSI
Z223.1 - latest edition or, in Canada, the CAN/
CSA-B149.1 codes - latest edition.
Manifold Gas Supply Pressure
(all models)
These fireplaces are designed as supplemental
heaters. Therefore, it is advisable to have an
alternate primary heat source when installed
in a dwelling.
Fuel #
Low
High
Natural (Lo) 2.2" WC
(Hi) 3.5" WC
(0.87 kPa)
Gas
(0.55 kPa)
(Lo) 6.3" WC (Hi) 10.0" WC
(1.57 kPa) (2.49 kPa)
Millivolt Models - The millivolt appliances are
manually controlled and feature a spark igniter
(piezo) that allows the appliance's pilot gas to
be lit without the use of matches or batteries.
This system provides continued service in the
event of a power outage.
Propane
Table 3
Installtheapplianceaccordingtotheregulations
of the local authorities having jurisdiction and,
in the USA, the National Fuel Gas Code NFPA
54 / ANSI Z223.1 - latest edition or, in Canada,
the CAN/CSA-B149.1 - latest edition.
Test gauge connections are provided on the
front of the millivolt and electronic gas control
valve (identified IN for the inlet and OUT for the
manifold side). The control valves have a 3/8"
(10mm) NPT thread inlet and outlet side of the
valve (refer to Figures 1 and 2).
Millivoltmodelscomestandardwithamanually-
modulated gas valve; flame appearance and
heat output can be controlled at the gas valve.
The BTU Input for these appliances is shown
in Table 1.
Flame breadth, height and width will dimenish
4% for every 1,000 feet of altitude.
Propane tanks are at pressures that will cause
damage to valve components. Verify that the
tanks have step down regulators to reduce the
pressure to safe levels.
Burner Orifice Sizes (all models)
Electronic Models - Electronic models have a
fixed rate gas valve. Input of electronic models
is shown in Table 1.
Natural
Propane
Elevation
Gas
Gas
Feet (meters)
drill size (inches)
drill size (inches)
0-4500
(0-1372)
These appliances must be isolated from the
gas supply piping system (by closing their
individual manual shut-off valve) during any
pressure testing of the gas supply piping
system at test pressures equal to or less
than 1/2 psig (3.5 kPa).
(0.125")
21L81 •
#41 (0.096")
*
*
Input (BTU) Gas Valves (all models)
21L82 •
All Models
Fuel
Type
Input Rate
(BTU / HR)
* Standard size installed at factory
• Part /Cat. Number
Table 4
39,000 high
31,000 low
Millivolt
Natural
Propane
Natural
Burn-in Period
Theseappliancesandtheirindividualshut-off
valves must be disconnected from the gas
supply piping system during any pressure
testing of that system at pressures greater
than 1/2 psig (3.5 kPa).
39,000 high
31,000 low
Millivolt
During the first few fires of this appliance there
will be some odor due to the curing of the
paint and burning off of lubricants used in the
manufacturing process. Depending on your
use, the burn-in period may take a few hours
or a few days.
(if field converted)
Electronic
39,000
39,000
Electronic
Propane
These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.
(if field converted)
KEEP YOUR HOUSE WELL VENTILATED
DURING THE CURING PROCESS. THE ODOR
AND HAZE EMITTED DURING THE CURING
PROCESS CAN BE QUITE NOTICEABLE AND
MAY SET OFF A SMOKE DETECTOR.
Table 1
Orifice Sizes - Sea Level to High Altitude
(All Models)
Gas Pressure - All Models
Tables 2 and 3 show the appliances' inlet and
manifold gas pressure requirements:
These appliances are tested and approved for
installation at elevations of 0-4500 feet (0-1372
meters)abovesealevelusingthestandardburner
orifice sizes (marked with an "*" in Table 4 ).
If an optional blower is installed, Do Not turn
it on during the Burn-In period.
Inlet Gas Supply Pressure
(all models)
A white film may develop on the glass front
during the first few fires as part of the curing
process. The glass should be kept clean during
thefirsttwoweeksofusetopreventthefilmfrom
baking on (making it very difficult to remove).
See Cleaning Glass on Page 10.
Fuel #
Minimum
Maximum
Forelevationsabove4500feet,contactyourgas
supplier or qualified service technician.
4.5" WC
(1.12 kPa)
10.5" WC
(2.61 kPa)
Natural Gas
11.0" WC
(2.74 kPa)
13.0" WC
(3.23 kPa)
Propane
Table 2
7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION AND CARE OF YOUR APPLIANCE
WARNING
Young children should be carefully supervised when they are in the
same room as the appliance. Toddlers, young children and others
may be susceptible to accidental contact burns. A physical barrier is
recommended if there are at risk individuals in the house. To restrict
access to a fireplace or stove, install an adjustable safety gate to keep
toddlers, young children and other at risk individuals out of the room
and away from hot surfaces.
Gas Valve
Control
Hinge Pin
ON/OFF
Switch
Compartment
Access panel
AVERTISSEMENT
Modesty Panel
Piezo Ignitor
Lesjeunesenfantsdevraientêtresurveillésétroitementlorsqu’ilssetrou-
ventdanslamêmepiècequel’appareil.Lestoutpetits,lesjeunesenfants
ou les adultes peuvent subir des brûlures s’ils viennent en contact avec
la surface chaude. Il est recommandé d’installer une barrière physique
si des personnes à risques habitent la maison. Pour empêcher l’accès
à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure
empêchera les tout petits, les jeunes enfants et toute autre personne à
risque d’avoir accès à la pièce et aux surfaces chaudes.
Control Compartment Access -
Millivolt Control Valve Shown
Figure 1
Refer to Figure 1 for access to the gas control
valve. Millivolt appliances will be fitted with the
gas control valve shown in Figure 2.
Remove the bottom compartment door by
sliding the hinge pin, located at the door’s left
side, to the right until it disengages from the
left corner post hole. Pull the door diagonally
to the left, away from the fireplace.
Gas Controls/Control Compartment
Access
Applianceswithelectronicsystemswillbefitted
with the electronic valve shown in Figure 3.
Familiarize yourself with the gas control valve
that your appliance uses.
Thegascontrolscanbefoundbehindthehinged
drop-down panel.
To open the hinged drop-down panel, actuate
the spring loaded magnetic catches securing
the door. First, gently depress the upper right
top corner of the panel until the magnet catch
"pops" the door free. Then, gently pulling the
panel forward, disengage the left magnet catch
and allow the panel to swing down to open.
To ease door closure, depress the catches to
place them in their retracted position until they
stay there, then close the door.
Operation of millivolt and electronic gas con-
trol systems are different. Before lighting and
operatingyourappliancedetermineifyouhave
a millivolt or electronic appliance.
On millivolt systems, the piezo ignitor, Hi/Lo
flame adjustment knob, and pilot and main gas
ON/OFFcontrolknobarelocatedonthemodesty
panel. On both millivolt and electronic systems
the gas valve is located behind the modesty
panel. See Figure 1.
8
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
Variable Flame Height Adjustment
( Millivolt Appliances only)
Variable Flame Height Adjustment
Manifold Pressure Port
Inlet Pressure Port
1. All Millivolt appliances are equipped with
a variable gas control valve. Flame height for
these models may be adjusted through a range
betweenfixedlowandhighsettings,alternately,
while the appliance is in operation.
O U T I N
F
O
F
T
O
N
Adjust the flame height as desired after lighting
theappliancebyrotatingthevariableadjustment
control knob located on the front of the valve
(refertoFigure 2). (An extensionis providedto
this knob so that the adjustment may be made
at the modesty panel.)
I
Main Gas
Control Knob
SIT Millivolt Gas Valve
Note: The piezo ignitor is located on the modesty panel - refer to Figure 1.
Figure 2
2. When lit for the first time, this appliance will
emitaslightodorforanhourortwo. Thisisdue
tothe“burn-in”ofinternalpaintsandlubricants
used in the manufacturing process.
If your millivolt appliance is equipped with an
optional remote wall switch or remote control
kit and the pilot is lit, the appliance main burner
may be turned on and off with the wall switch
or remote control.
ON/OFF Switch
Manifold Pressure Port
3. Keep lower control compartment clean by
vacuuming or brushing at least twice a year.
More frequent cleaning may be required due to
excessivelintfromcarpeting,beddingmaterials,
etc. It is important that control compartments,
burners and circulating air passageways of the
appliancebekeptcleanandclearofobstruction
of venting and combustion air.
Inlet
Pressure
Port
Electronic Appliances -
To light electronic appliances refer to the
detailed lighting instructions found in both
English and French on pages 28 and 29 of
these instructions respectively. Electronic
appliance lighting instructions may also be
foundonthepulloutlightinginstructionlabels
attached to the gas control valve. Electronic
appliances are fitted with an ON/OFF Rocker
Switch for appliance ON/OFF control. Refer to
Figure 1 for its location.
Electronic
Gas Control
Valve
4. Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before re-lighting,
refer to the lighting instructions in this manual.
Instructions are also found on a pull-out panel
located on the floor of the appliance.
Honeywell Electronic
Gas Valve
Figure 3
Millivolt Appliances -
5. Always keep the appliance area clear and
free from combustible materials, gasoline and
other flammable liquids.
To light millivolt appliances refer to the detailed
lightinginstructionsfoundonpage 26(English)
and page 27 (French). Millivolt appliance
lighting instructions may also be found on the
pull out lighting instruction labels attached to
the gas control valve.
Once the pilot is lighted, the ON/OFF rocker
switchwillcontroltheapplianceON/OFFopera-
tion. To operate: Toggle the switch between its
ON and OFF positions.
6.Remember,Millivoltapplianceshaveacontin-
uousburningpilotflame.Exercisecautionwhen
using products with combustible vapors.
If your electronic appliance is equipped with an
optionalremotewallswitchorremotecontrolkit
theappliancemainburnermaybeturnedonand
off with the wall switch or remote control.
Millivolt appliances are fitted with an ON/OFF
Rocker Switch for appliance ON/OFF control.
Refer to Figure 1 for its location. Once the
pilot is lighted, the ON/OFF rocker switch will
control the appliance ON/OFF operation. To
operate: Toggle the switch between its ON and
OFF positions.
9
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing Logs
The viewing glass should be cleaned periodi-
cally to remove any build-up caused from the
following:
MAINTENANCE
If the logs become damaged by accident or
improper handling and need replacement, use
only the proper replacement logs from manu-
facturer (see Pages 13 and 14 for ordering
information).
(See Maintenance Schedule, Page 25)
IMPORTANT: Do not use abrasive clean-
ers on glass. Never clean the glass when
it is hot.
Refertothemaintenancescheduleformaintenance
tasks, procedures, periodicity and by whom they
shouldbeperformed. Alwaysverifyproperopera-
tion of the appliance after servicing.
• During start-up, it is normal for condensa-
tion to form on the inside of the glass (this
condensation and fog will usually disappear
in a few minutes). The moisture can cause
lint,dustandotherairborneparticlestocling
to the glass surface.
• Initial curing of the high temperature paint
and burning off of lubricants used in the
manufacturing process may result in a film
on the glass.
Re-Install Embers and Logs
WARNING
Carefully follow placement instructions on
Pages 12 through 14. All logs should fit
onto corresponding pins and/or log stop-
pers. This will ensure a proper flame and
safe combustion.
Turnoffgasandelectricalpower
to the fireplace and allow it to
coolbeforecleaningorservicing
the appliance.
Inspect Wiring
Refer to wiring diagrams on Page 17.
• A white coating may form on the glass as a
result of impurities and minerals in the fuel.
CAUTION: Wear gloves and safety
glasses for protection while doing
required maintenance.
CAUTION: Labelallwirespriortodiscon-
nection when servicing controls. Wiring
errorscancauseimproperanddangerous
operation. Verify proper operation after
servicing.
It is recommended that the glass be cleaned
two or three times during each heating season,
depending on the circumstances present. The
following cleaning solutions are approved for
use to clean glass:
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adé-
quatement une fois l'entretien terminé.
ATTENTION: Au moment de l'entretien
des commandes, étiquetez tous les fils
avant de les débrancher. Des erreurs de
cáblage peuvent entraîner un fonction-
nement inadéquat et dangereux.
• Non-ammonia based household cleaner
• 50%-50% mix of white vinegar and water
• Gas fireplace/stove glass cleaner
Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before re-
lighting, refer to the lighting instructions
inthismanual.Instructionsarealsofound
on a pull-out panel located in the control
compartment.
Inspect Glass Gasket - Visually inspect the
gasket on the backside of the glass enclosure
panels. The gasket surface must be clean, free
of irregularities and seated firmly.
Inspect and clean all wire connections. Ensure
that there is no melting or damage. Inspection
should include:
• Terminals at the Valve
• OFF/ON Switch
• (Optional Control Switch) Wall Thermostat,
Remote Control or Remote Wall Switch Kit
Inspect Venting System
Clean Control Compartment
The appliance and venting system should be
thoroughly inspected before initial use and
at least annually by a qualified service techni-
cian (inspection should include ensuring that
exhaust or intake passages are unobstructed
and vent components are properly assembled
and not damaged). Homeowner must contact
a qualified service technician at once if any
abnormal condition is observed.
Keepcontrolcompartmentcleanbyvacuuming
or brushing at least twice a year. More frequent
cleaning may be required due to excessive lint
from carpeting, bedding materials, etc. It is
important that control compartments, burners
andcirculatingairpassagewaysoftheappliance
be kept clean.
Inspect Burner Flame Appearance
Ensure that the burner flame appearance
resembles the flame shown in Figure 9 and
asdescribedinFlameAppearanceandSooting
on Page 15. The Homeowner must contact
a qualified service technician at once if any
abnormal condition is observed.
Clean Logs And Burner
If the venting system is disassembled for any
reason, a qualified service technician should
follow vent installation instructions for proper
reassembly and proper sealing of the venting
system components. However, more frequent
periodic inspections and cleanings should be
performed by the homeowner.
Carefully remove the logs (use care when han-
dlingthefiberlogs,astheybecomequitefragile
after curing). Vacuum out any foreign matter
(lint, carbon, etc.) on the burner. Ensure the
burner ports are “open.” Remove any carbon
deposits from the under side of the logs using
a vacuum cleaner, or a soft bristled brush (i.e.
paint brush).
Small Area Paint Touch-up
Only use a factory supplied paint kit for touch-
ups. Paint is available at your local authorized
LennoxHearthProductsdealer. Neverattempt
to paint a hot fireplace.
Cleaning Glass
(see Front Glass Enclosure Panel, Removal and
Installation on Page 11).
Do not attempt to repaint the appliance until
the finish is completely cured (see Burn-In
Period onPage7).Ifthesurfacelaterbecomes
stainedormarred, itmaybelightlysandedand
touched up with spray paint.
Note: Improper positioning of logs can create
carbon build-up and will alter the performance
of the appliance.
Note: Cleanglassafterfirsttwoweeksofopera-
tion(afterBurn-Inperiodisover)andthenonly
when necessary and when the fireplace is cool.
Wipesurfacewithaclean,dampened,softcloth.
Follow with a dry, soft towel as desired. Take
care not to scratch the glass surface.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Locate the two (2) latches at the top of the
controlcompartmentanddisengagethemfrom
thedoorframebottomvee-flange,pullingdown
on their handles to open them.
Front Glass Enclosure Panel, Removal
and Installation
WARNING
Any safety screen or guard
removed for servicing the appli-
ance must be replaced prior to
operating the appliance.
WARNING
Retrieve the glass door. Visually inspect the
gasket on the backside of the frame. Gasket
surface must be clean, free of irregularities
and seated firmly.
• Do not attempt to substitute
the materials used on this door,
or replace cracked or broken
glass.
•Handlethisglasswithextreme
care! Glass is susceptible to
damage – Do not scratch or
handle roughly while reinstall-
ing the glass door frame.
• The glass door(s) of this appli-
ance must only be replaced as a
completeunitasprovidedbythe
manufacturer. Do not attempt
to replace broken, cracked or
chipped glass separately.
•Donotattempttotouchthefront
enclosureglasswithyourhands
while the fireplace is in use.
AVERTISSEMENT
Position the door in front of the firebox opening
with the bottom of the door held away from the
fireplace (Figure 4 ). Hook the top flange of the
door frame over the top of the firebox frame.
Tout écran ou protecteur retiré
pour permettre l’entretien de
l’appareil doit être remis en
place avant de mettre l’appareil
en marche.
Let the bottom of the door frame swing gently
intowardsthefireplaceensuringthatthegasket
seats evenly as the door frame draws shut.
Fasten the two latches located underneath the
firebox floor to the door's vee-flange. Close
both the latches securely.
Only doors certified with the appliance
shall be used.
Seules des portes certifiées pour cet
appareil doivent être utilisées.
Control Compartment Access Panel and Hinge
Top Flange
Glass Door Frame
CAUTION: DO NOT abuse glass door by
striking or slamming shut.
Front Glass
Enclosure Panel
These are direct-vent appliances. They are
designed to operate only when the front glass
enclosure panels are installed. Generally the
front glass enclosure panel should not be re-
moved except to gain access to the components
within the firebox.
WARNING
Do not operate appliance with
theglassfrontremoved,cracked
or broken.
Removing Glass Enclosure Panels
(see Figure 4 )
Remove the top louver assembly or radiant
panel.
Bottom Vee-flange
Glass Door Frame
AVERTISSEMENT
Firebox Floor
Glass Door Latch
Ne pas utiliser l'appareil si le
panneau frontal en verre n'est
pas en place, est craqué ou
brisé.
To access the glass door securing latches,
first open the lower control compartment door
(Figure4)bypushinginsimultaneouslytheleft
and right top corners of the door. (The door
is hinged at the bottom.) Remove the bottom
compartment door by sliding the hinge pin,
located at the door’s left side, to the right until
it disengages from the left corner post hole.
Pull the door diagonally to the left, away from
the fireplace.
Figure 4
EDVST SHOWN
INSTALL VERMICULITE, GLOWING EM-
BERS AND LOGS
NOTE: Turn off all electricity to the appliance
beforeyouinstallvermiculite,embersandlogs.
DO NOT attempt to install the logs until the ap-
plianceinstallationhasbeencompleted,thegas
lineconnectedandtestedforleaksandtheinitial
burner operation has been checked out.
11
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEPS:
REFERENCE
Firebox Accessories / Parts
READ WARNINGS ON THIS PAGE BEFORE PROCEEDING. FOLLOW THE
LOG PLACEMENT INSTRUCTIONS EXACTLY
Cat. No.
88L53
Model No.
Description
FGE
Bag of Glowing Embers
1. Remove the front glass enclosure panel (see Glass Enclosure Panel
Removal and Installation Instructions, Page 11 ).
80L42
FDVS
Bag of Decorative Volcanic Stone
2. Remove the following from firebox; log set, bag of embers and bag
of vermiculite. Handle logs carefully to prevent breakage.
3. Ensure the Grate is properly installed in the firebox with the 4 legs
of the grate fitting into the 4 dimples on the firebox floor.
4. Placement of Glowing Embers -
WARNING
• DO NOT attempt to install the logs until the appli-
ance installation has been completed, the gas line
connected and tested for leaks and the initial burner
operation has been checked out.
• Thesizeandpositionofthelogsetwasengineered
to give the appliance a safe, reliable and attractive
flame pattern. Any attempt to use a different log
set in the fireplace will void the warranty and will
result in incomplete combustion, sooting, and poor
flame quality.
• Logs get very hot and will remain hot up to one
houraftergassupplyisturnedoff. Handleonlywhen
logs arecool. Turnoffallelectricitytotheappliance
beforeyouinstallgrate,volcanicstone,vermiculite,
embers and logs.
Separatethe Embers(rockwool)intopiecesabout thesizeofaquarter
(see Figure 5). Keep the pieces fluffed up, not matted. Distribute
these pieces over the surface of the burner, as shown in Figure 6.
Do not use more than is necessary. Ensure that the main burner ports
remain uncovered by the ember material.
5. Place Lava Rock - Spread lava rock evenly over firebox floor.
6. Install Vermiculite - Place some vermiculite on the firebox floor
around the grate (the entire bag of vermiculite will NOT be used). See
Figure 6. DO NOT PLACE ANY VERMICULITE ON THE BURNER.
Note: This appliance is provided with enough Glowing Embers for several
applications, do not use all that is in a new bag at one time. For best
glowingeffect,replacetheembermaterialannually.ReplacementGlowing
Embers are available (order Catalog Number 88L53).
• This appliance is not designed to burn wood. Any
attempt to do so could cause irreparable damage to
the appliance and prove hazardous to your safety.
• If logs are not installed according to the log
installation instructions, flame impingement and
impropercombustioncouldoccurandresultinsoot
and/or excessive production of carbon monoxide
(CO), a colorless, odorless, toxic gas.
Figure 5
Glowing Embers
Figure 6
12
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
EDVPF, EDVST, EDVCL AND EDVCR LOG PLACEMENT
Log
Part
Number
6
4
2
Number Description
1
2
3
4
5
6
Log, Corner
55M18
55M19
55M20
55M21
55M22
55M23
Log, Rear/Left
Log, Front/Left
Log, Rear/Right
Log, Front/Center
Log, Center/Top
Catalog Number for the entire log set: 55M04
1
3
5
Log (3) Lays Over Logs
3
1 And 2
STEP 3
1
STEP 1
Place Bottom Hole Of Log (3) On Pin In Log (2). Position
Grooves At The Bottom Of Log (3) Over The Grate.
Position Groove At The
Bottom Of Log (1) Over
The Burner Log Support
Bracket
Position The Groove At The
Bottom Of Log (1) Over The
Grate And Slide It Forward
Against The Grate Here
Position And Slide Log (4)
1
Against The Back Of The Grate
STEP 4
Position Log (2) Over The Grate
Bar And Slide It Against The Back
Of The Grate Here
2
STEP 2
Place Log (4) Over
4
The Flat Spot On
Position Groove At The Bottom Of Log (2)
Over The Grate Here And Slide It Against
The Back Of The Grate
Log (1) Here
Figure 7
13
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
EDVPF, EDVST, EDVCL AND EDVCR LOG PLACEMENT (CONTINUED)
Log
Part
Number
6
4
Number Description
2
1
2
3
4
5
6
Log, Corner
55M18
55M19
55M20
55M21
55M22
55M23
Log, Rear/Left
Log, Front/Left
Log, Rear/Right
Log, Front/Center
Log, Center/Top
Catalog Number for the entire log set: 55M04
3
1
5
Position The Round End Of Log (6)
Against The Notch Of Log (4) Here.
Two Charred Spots Face The Front
Position Small End Of Log (6)
On The Notch Of Log (3) Here
6
STEP 5
3
4
Rest Log (5) Against
The Grate Here
Grate
Assembly
Position The Groove In The Back
Of Log (3) Against The Grate
Log (5) Sits In Front
Of The Grate
5
Figure 8
14
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
Air Shutter Adjustment Guidelines
The following chart is provided to aid you in
achieving the correct air shutter adjustment
for your installation.
BURNER ADjUSTMENTS
(QUALIFIED TECHNICIANS ONLY)
• If there is smoke or soot present, first
check the log set positioning to ensure that
the flames are not impinging on any of the
logs. If the log set is properly positioned
and a sooting condition still exists, then the
air shutter opening should be increased.
• Themoreoffsetsintheventsystem,thelarger
the air shutter opening will need to be.
• An appliance operated with the air shutter
opened too far, may have flames that appear
blue and transparent. These weak, blue and
transparent flames are termed anemic.
• Propane models may exhibit flames which
candle or appear stringy. If this is present
and persists, adjust the air shutter to a more
closed position, then operate the appliance
for a few more minutes to ensure that the
flame normalizes and the flames do not
appear sooty.
Flame Appearance and Sooting
Air Shutter Adjustment Guidelines:
Proper flame appearance is a flame which is
blueatthebaseandbecomesyellowish-orange
in the body of the flame.
Amount of
Primary Air
Flame
Color
Air Shutter
Adjustment
If air shutter is
closed too far
Flame will Air shutter
be orange gap should be
increased
When the appliance is first lit, the entire flame
may be blue and will gradually turn yellowish-
orangeduringthefirst15minutesofoperation.
If the flame remains blue, or if the flame is
orange with evidence of sooting (black tip), the
air shutter opening may need to be adjusted.
If air shutter is
open too far
Flame will Air shutter
be blue gap should be
decreased
If the air shutter opening is closed too far,
sooting may develop. Sooting is indicated by
black puffs developing at the tips of very long
orangeflames. Sootingresultsinblackdeposits
forming on the logs, appliance inside surfaces
and on exterior surfaces adjacent to the vent
termination.
Sooting is caused by incomplete combustion
in the flames and lack of combustion air enter-
ing the air shutter opening. To achieve a warm
yellowish-orange flame with an orange body
that does not soot, the shutter opening must be
adjusted between these two extremes.
Glowing Embers (Rockwool)
Figure 9 - Burner Flame Appearance
15
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
BURNER FLAME ADjUSTMENTS
Air Shutter
Adjusting
Rod
Hood Igniter Rod
MILLIVOLT
Thermocouple
WARNINGS
Orifice
• Airshutteradjustmentshould
only be performed by a quali-
fiedprofessionalservicetech-
nician.
• Ensure front glass panel are
in place and sealed during
adjustment.
3/8" Min
(9 mm)
Pilot
Increase Shutter
Nozzels
Opening In This
Direction
Thermopile
Decrease Shutter
Opening In This
Direction
Figure 11
Note - Burners are omitted in this view for clarity.
CAUTIONS
Electronic Appliance Checkout
• Soot will be produced if the
airshutterisclosedtoomuch.
Any damage due to sooting,
resulting from improperly
setting the air shutter, is not
covered under the warranty.
• The air shutter door and
nearby appliance surfaces
are hot. Exercise caution to
avoid injury while adjusting
flame appearance.
MAIN BURNER
FACTORY SHUTTER SETTING
Natural Gas Propane Gas
To light the burner, turn ‘ON’ the unit mounted
On/Offswitchortheoptionalremotewallswitch.
Ensure the igniter lights the pilot. The pilot
flame should engulf the flame rod as shown
in Figure 12.
Models
inches
(mm)
inches
(mm)
EDVST
EDVPF
EDVCR
EDVCL
1/4"
(6.35)
5/8"
(15.88)
ELECTRONIC
3/8 To 1/2 Inch
(9 mm to 13 mm)
Proper Flame
Adjustment
Adjustment Rod Positions (when viewed from above)
Figure 10
Pilot
Nozzle
Ground
1. Refer to Figure 9 for proper flame ap-
pearance. To adjust the flame, rotate the
adjustment rod toward the back or toward
the front of the fireplace (rod located in
the lower control area). Position the air
shutter to the factory setting as shown in
the table in Figure 10.
2. Light appliance (follow lighting procedure
on lighting label in control compartment
or see the Care and Operation Manual).
3. Allow the burner to operate for at least 15
minutes while observing the flame con-
tinuously to ensure that the proper flame
appearance has been achieved. If the
following conditions are present, adjust
accordingly.
Electrode
Millivolt Appliance Checkout
Flame Rod
The pilot flame should be steady, not lifting
or floating. Flame should be blue in color with
traces of orange at the outer edge.
Hot Surface
Igniter
Figure 12
The top 3/8" (10 mm) at the pilot generator
(thermopile) and the top 1/8" minimum (tip)
of the quick drop out thermocouple should be
engulfed in the pilot flame.
Theflameshouldproject1"(25mm)beyondthe
hoodatallthreeports(seeFigure11). Replace
logs if removed for pilot inspection.
To light the burner; turn “ON” the remote wall
switch and rotate the gas valve control knob
counterclockwise to the “ON” position (“ON”
will be at the top side of the valve).
•
If flame appears weak or sooty, adjust
the air shutter, incrementally, to a
more open position until the proper
flame appearance is achieved.
•
If flame remains blue, adjust the air
shutter, incrementally, to a more
closed position until the proper flame
appearance is achieved.
4. Leave the control knob (off/pilot/on)
in the ON position and the burner OFF/
ON switch OFF (and remote switches, if
applicable).
5. When satisfied that the burner flame ap-
pearance is normal, re-install the lower
control compartment door then proceed
to finish the installation.
16
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING DIAGRAMS
ATTENTION: AU MOMENT DE L'ENTRETIEN DES COMMANDES, ÉTIQUETEZ
TOUS LES FILS AVANT DE LES DÉBRANCHER. DES ERREURS DE CÁBLAGE
PEU-VENT ENTRAÎNER UN FONCTIONNEMENT INADÉQUAT ET DANGEREUX.
Wiringdiagramsareprovidedhereforreference
purposesonly. Thisinformationisalsoprovided
onschematicsattacheddirectlytotheappliance
on a pullout panel located within the control
compartment.
Electronic Wiring Diagram (Honeywell)
Showing the Blower Wiring for the Optional
FBK-250 Kits
Electronic Wiring Diagram (Honeywell)
Showing the Blower Wiring for the Optional
FBK-100 and FBK-200 Kits
1. If any of the original wire as supplied must be replaced,
1. it must be replaced with Type AWM 105°C – 18 GA. wire.
2. 120V, 60Hz – Less than 3 amps.
1. If any of the original wire as supplied must be replaced,
1. it must be replaced with Type AWM 105°C – 18 GA. wire.
2. 120V, 60Hz – Less than 3 amps.
CAUTION:LABELALLWIRESPRIORTO
DISCONNECTION WHEN SERVICING
CONTROLS. WIRING ERRORS CAN
CAUSEIMPROPERANDDANGEROUS
APPLIANCE OPERATION.
**Leave the ON/OFF switch, which is integral
**ON/OFF Switch (Integral
*Leave the ON/OFF switch, which is integral
with the gas valve, in the ON position.
*ON/OFF Switch (Integral
with Gas Valve)
with the gas valve, in the ON position.
with Gas Valve)
Gas Valve
PILOT
Gas Valve
PILOT
ASSEMBLY
ASSEMBLY
Ground - Green
Neutral - White
BK
120 VAC - Black
BK
Optional
FBK-250
Module
R
R
Green
BL
White
Black
Ground - Green
Neutral - White
120 VAC - Black
BL
Green
White
Black
Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced,
it must be replaced with Type AWM 105° C – 18 GA. wire.
OPT
BLOWER
junction Box
OPT
BLOWER
Tab Intact
junction Box
Ta b
Broken
Tab Intact
Ta b
Broken
Red
Optional
Accessory
Switch
Green
Ground
Screw
Hot
Neutral
Red
Optional
Accessory
Switch
Side of
Side of
Green
Ground
Screw
Receptacle
Receptacle
Hot
Neutral
Side of
Receptacle
Side of
W
Receptacle
Transf.
120 V.
B
W
B
G
Transf.
120 V.
G
Thermopile
24 V
BL
24 V
BL
R
Field Wired
Factory Wired
W
R
BK
WH
BK
APPLIANCE-MOUNTED ON/OFF SWITCH
*OR OPTIONAL WALL-MOUNTED ON/OFF SWITCH
OR OPTIONAL THERMOSTAT
OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH
OR OPTIONAL WALL SWITCH
OR OPTIONAL REMOTE CONTROL RECEIVER
OR OPTIONAL THERMOSTAT
OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH
OR OPTIONAL WALL SWITCH OR OPTIONAL THERMOSTAT
OR OPTIONAL REMOTE RECEIVER
OR OPTIONAL REMOTE RECEIVER
*Turn the appliance-mounted ON/OFF burner control switch
to the OFF position if an optional
*Blower speed control switch is provided in FBK200 blower kit.
control switch is installed.
Factory Wired
Field Wired
Factory Wired
Field Wired
Schematic Representation Only
Schematic Representation Only
Schematic Representation Only
WARRANTY
LENNOX HEARTH PRODUCTS
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
1-800-9-LENNOX
Parts will be shipped at prevailing prices at
time of order.
Your gas appliance is covered by a twenty year
limitedwarranty. Youwillfindacopyofthewar-
ranty accompanying this manual. Please read
the warranty to be familiar with its coverage.
When ordering repair parts, always give the
following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
PRODUCT REFERENCE INFORMATION
Retain this manual. File it with your other docu-
ments for future reference.
We recommend that you record the following
important information about your fireplace.
Please call Lennox Hearth Products for the
phone number of your nearest Lennox Hearth
Productsdealerwhowillansweryourquestions
or address your concerns.
REPLACEMENT PARTS
If you encounter any problems or have any
questions concerning the installation or ap-
plication of this system, please contact your
dealer or distributor.
A complete parts list is found at the end of
this manual. Use only parts supplied from the
manufacturer.
Withpropercareandmaintenance, yourappli-
ance will provide many years of enjoyment. If
you should experience any problem, first refer
to the troubleshooting guide in this manual. If
problem persists, contact your Lennox Hearth
Products dealer or distributor.
Your Fireplace's Model Number___________________________________________
Your Fireplace's Serial Number ___________________________________________
The Date On Which Your Fireplace Was Installed______________________________
The Type of Gas Your Fireplace Uses _______________________________________
Your Dealer's Name ___________________________________________________
Normally,allpartsshouldbeorderedthroughyour
Lennox Hearth Products distributor or dealer.
17
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY COMPONENTS
Product Reference Information
Cat. No.
Model
Ship.
Weight
Ship.
Volumn
H0721
H0722
H0723
H0724
H0725
H0726
H0727
H0728
H0729
H0730
H0731
H0732
EDVSTNM
EDVSTNE
EDVSTPM
EDVPFNM
EDVPFNE
EDVPFPM
EDVCLNM
EDVCLNE
EDVCRNM
EDVCRNE
EDVCLPM
EDVCRPM
282 lbs.
282 lbs.
282 lbs.
270 lbs.
270 lbs.
270 lbs.
272 lbs.
272 lbs.
272 lbs.
272 lbs.
272 lbs.
272 lbs.
(36.2 cu.ft.)
(36.2 cu.ft.)
(36.2 cu.ft.)
(36.2 cu.ft.)
(36.2 cu.ft.)
(36.2 cu.ft.)
(36.2 cu.ft.)
(36.2 cu.ft.)
(36.2 cu.ft.)
(36.2 cu.ft.)
(36.2 cu.ft.)
(36.2 cu.ft.)
Flame Modulating Remote Control
– Natural Gas
Flame Modulating Remote Control
– LP/Propane Gas
H0301
H0302
RCL-MN
RCL-ML
Remote Control Kit, Deluxe
Cat. No.
H0251
Model No.
RCL-STAT
Description
Remote Control System
(Deluxe)
Flame Modulating Remote Control
Deluxe Remote Control System
FlameModulatingRemoteControlsweredevel-
opedtoprovideasafe,reliableanduser-friendly
remotecontrolsystemforappliancesequipped
with a Millivolt Gas Valve. A detailed set of
instructions are included with each remote.
The Model RCL-T (Deluxe) Remote Control System
has all of the features of the standard system along
withanaddedeasytoreadLCDscreenwhichpresents
access to many enhancements, including; battery
power level indicator, timer, mode of operation,
thermostatic display including room temperature in
either metric of English units, flame indicator and
clock. Fully programmable, the Model RCL-T allows
for virtual command over nearly all operational and
temperature variables, using the hand held remote
control transmitter.
The Model RCL-T (Deluxe) remote control system
is installed in the same manner as the standard
system, may be operated with electronic and mil-
livolt systems with either natural gas or propane gas.
The RCL-T comes complete with detailed operating
instructions.
Remote Control Kit, Standard
Cat. No.
H0249
Model No.
RCL
Description
Remote Control System
(Standard)
Forced Air Blower Kits
Standard Remote Control System
Cat.
No.
Model No.
FBK-100
FBK-200
FBK-250
Description
The Model RCL (Standard) Remote Control System,
features a simplistic OFF/ON control function for the
fireplace. Thismodelincludesahand-heldtransmitter,
a remote receiver with wall-mount cover plate and
all hardware required to install the unit. The remote
receiver can be wall or hearth mounted.
80L84
80L85
80L86
Blower, Standard
(single speed)
Blower, Variable Speed
(w/wall-mounted switch)
The transmitter has ON and OFF functions that are
activated by pressing either button on the face of
the transmitter. When a button on the transmitter
is pressed, a signal light illuminates briefly to verify
that a signal has been sent.
Blower, Variable Speed (w/
unit-mounted switch)
94L89
94L90
FBK-100-36
FBK-200-36
Blower, Standard, 36 Pack
Forced Air Kit
TheFBK-100blowerprovidesconstantvelocityforced
air circulation. The FBK-200 assembly with variable
speed,wall-mountableswitchprovidesvariablespeed
forced air circulation. The FBK-250 assembly with
variable speed unit-mountable switch, also provides
variable speed forced air circulation.
Blower Kit - Variable Speed
with Wall Switch 36 Pack
The Model RCL is designed to operate with all mil-
livolt ignition systems, as well as electronic ignition
systems. It may be installed with use for either
natural gas or propane gas appliances. The RCL
offers ease of installation and allows you to execute
on-off commands to the fireplace effortlessly with
one simple motion.
H0543
FBK-250-36
Blower Kit - Variable Speed
with Thermo Snap Switch
36 Pack
TheModelRCLcomescompletewithdetailedoperat-
ing instructions.
18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY COMPONENTS CONTINUED
Door Frame Kits
Adecorativedoorframekitisavailableforuse
with these appliances. The DTK is designed
to attach directly to the front face of the appli-
ance at its extreme edges. The DTK provides
a picture frame finish for the appliance. The
door frame kit can be retrofitted onto previ-
ously installed appliances.
I
Touch-Up Paint Kits
Cat. No.
90L73
Model No.
TPK-B
Description
Touch-Up Paint (Black)
Touch-Up Paint Kit
Repair of minor scratches and discoloration of the
appliance charcoal painted surfaces may be accom-
plished with the touch-up paint kit.
Door Frame Kits
CATALOG NO. / MODEL NO. AND NUMBER OF SETS
Polished Brass Finish
Brushed Stainless Finish
Unit
Model
No.
for 24 in. wide for 40 in. wide for 24 in. wide for 40 in. wide
Glass Door
Glass Door
Glass Door
Glass Door
88L43
DTK24PB-2
88L45
DTK40PB-2
90L69
DTK24BS
90L71
DTK40BS
EDVST
EDVPF
EDVCR
EDVCL
-
1
2
2
-
1
2
2
Decorative Firebox Accessories
1
1
1
1
Cat. No.
88L53
Model No.
FGE
Description
Bag of Glowing Embers
Bag of Decorative
Volcanic Stone
80L42
FDVS
Arch Door Kits
Bag of Glowing Embers
Two types of arch door kits are available for
the Multi-Open Series. Both types of kits are
easy to install and do not require hardware to
attach them to the standard door frame. These
kits can be retrofitted to previously installed
Multi-Open Series appliances. The decorative
arch kits can not be used in conjunction with
the screen panel kit.
Bag of Volcanic Stone
Replacement ember materials or volcanic stone are
available for use with these appliances. Order kits as
part of the periodic maintenance of the appliance.
Arch Door Kits - CATALOG NO. / MODEL NO. AND QUANTITY
Polished Brass Finish Brushed Stainless Finish
for 24 in. wide for 40 in. wide for 24 in. wide for 40 in. wide
Unit
Model
No.
Glass Door
Glass Door
Glass Door
Glass Door
81L37
ADK24CPB
81L35
ADK40CPB
98L71
ADK24CBS
98L69
ADK40CBS
EDVST
EDVPF
EDVCR
EDVCL
-
1
2
2
-
1
2
2
1
1
1
1
19
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY COMPONENTS CONTINUED
Black Finish Louvers Kits
Decorative louvers are available for use with all
Multi-Open Series appliances. These louvers are
designed to replace the standard radiant panels
that are provided with the appliance. These kits
include a black finish top 3-piece assembly and
a bottom 3-piece assembly. These kits can be
retrofitted to previously installed appliances.
Wall Thermostat, Millivolt
Cat. No.
H4635
Model No.
DWTK
Description
Wall Thermostat Kit,
White
Black Finish Louver Assembly Kits
(3-piece Top and 3-piece Bottom Assembly)
CATALOG NO. / MODEL NO. AND NUMBER OF SETS
Digital Wall Thermostat
The wall thermostat kit provides temperature control
for optimum comfort.
Black Finish
Unit
Model
No.
for 24 in. wide
Glass Door
for 40 in. wide Glass
Door
88L23
LVR24C-2
88L25
LVR40C-2
EDVST
EDVPF
EDVCR
EDVCL
-
1
2
2
1
1
White Wall Switch Kit
Polished Brass and Brushed Stainless
Hood Kits
Cat. No.
85L87
Model No.
FWSK
Description
OFF/ON Wall Switch Kit
Attractive hoods are available in two styles to be
used on the Multi-Open Series appliances. These
hoodsaredesignedtobefittedtotheglassviewing
sides of the appliance. In addition to providing an
aestheticallypleasingappearancetoyourappliance
installation, thehoodreducesheateffectstodeco-
rative mantles and finish materials located above
the fireplace opening. The hood kit replaces the
standard hood that comes with these appliances
and snaps into place. These kits can be retrofitted
to previously installed appliances.
OFF/ON Wall Switch Kit
The OFF/ON wall switch kit may be used to control
the operation of the fireplace burner. Install the OFF/
ON wall switch in a convenient location near the
fireplace.
Hood Kits
CATALOG NO. / MODEL NO. AND NUMBER OF SETS
Polished Brass Finish
Brushed Stainless Finish
Unit
Model
No.
for 24 in. wide for 40 in. wide for 24 in. wide
for 40 in. wide
Glass Door
Glass Door
Glass Door
Glass Door
96K28
EB24PB
96K68
EB40PB
88L47
EB24BS
88L50
EB40BS
EDVST
EDVPF
EDVCR
EDVCL
-
1
2
2
-
1
2
2
1
1
1
1
20
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY COMPONENTS CONTINUED
2-Piece Polished Brass and Brushed
Stainless Louvers Kits
Decorative louvers are available for use with all
Multi-OpenSeriesappliances.Theselouversare
designed to replace either the middle charcoal
louver of each set or the charcoal louver in each
set closest to the glass door. These kits include
two narrow louvers. They provide a touch of
elegance to any Multi-Open Series appliance.
These kits can be retrofitted to previously
installed appliances.
Screen Panel Kit
24 inch Wide Glass Door
40 inch Wide Glass Door
98K74
96K32
HG24
HG40
Louver Kits (2-piece)
CATALOG NO. / MODEL NO. AND NUMBER OF SETS
Screen Panel Kit
Anoptionalscreenpanelcanbeinstalledonthe
Multi-Open Series doors. These screen panels
are easy to install. These kits can be retrofitted
to previously installed appliances. The screen
panel kits can not be used in conjunction with
either of the arch door kits or door frame kits.
Polished Brass Finish
Brushed Stainless Finish
Unit
Model
No.
for 24 in. wide for 40 in. wide for 24 in. wide
for 40 in. wide
Glass Door
96L04
Glass Door
96L06
Glass Door
96L08
Glass Door
96L10
2LVR24PB
2LVR40PB
LVR24BS
LVR40BS
EDVST
EDVPF
EDVCR
EDVCL
-
1
2
2
-
1
2
2
1
1
1
1
Polished Brass and Brushed Stainless
Louvers Kits
Decorative louvers are available for use with all
Multi-OpenSeriesappliances.Theselouversare
designedtoreplacethestandardradiantpanels
that are provided with theappliance. These kits
include a top 3-piece assembly and a bottom
3-piece assembly. They provide a touch of
elegance to any Multi-Open Series appliance.
These kits can be retrofitted to previously
installed appliances.
Louver Assembly Kits (3-piece Top and 3-piece Bottom Assembly)
CATALOG NO. / MODEL NO. AND NUMBER OF SETS
Polished Brass Finish
Brushed Stainless Finish
Unit
Model
No.
for 24 in. wide for 40 in. wide for 24 in. wide for 40 in. wide
Glass Door
Glass Door
Glass Door
Glass Door
88L27
LVR24PB-2
88L29
LVR40PB-2
88L31
LVR24BS
88L33
LVR40BS
EDVST
EDVPF
EDVCR
EDVCL
-
1
2
2
-
1
2
2
1
1
1
1
21
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY COMPONENTS CONTINUED
Bricaded Panel Liner Kits
Catalog No.
Model No.
Model No.
H0778
EBLK-PF
EDVPF
H0779
EBLK-ST
H0780
EBLK-CL
H0781
EBLK-CR
EDVST
EDVCL
H0779
(Top Vent)
EDVCR
The brickaded liner kits include
ceramic panels as shown here.
Thepanelshavebrick-likefeatures
in relief.
H0780 & H0781
(Top Vent)
H0778
(Top Vent)
H0779
(Rear Vent)
H0778
(Rear Vent)
H0780 & H0781
(Rear Vent)
22
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY COMPONENTS CONTINUED
Style View Doors -
Style View Doors come in 4 beautiful styles. They are easy to install and will not require hardware to attach them to the
standard glass door frame. The door includes heavy duty magnet door latches and functional twin-pane doors.
Arch Design
Square Design
Arch Pane Design
Square Pane Design
ARCH DESIGN KITS
SQUARE DESIGN KITS
Description
Cat. No.
H0862
H0863
H0864
H0865
Model
AD40C
Description
Model Series
Cat. No.
H0950
H0951
H0952
H0953
Model
SD40C
Model Series
40” Arch Doors, Black
40” Sq. Doors, Black
EDVST
EDVPF
EDVCR
EDVCL
EDVST
EDVPF
EDVCR
EDVCL
AD40TI
AD40SP
AD40AB
40” Arch Doors, Textured Iron
40” Arch Doors, Satin Pewter
40” Arch Doors, Antique Brass
ARCH PANE DESIGN KITS
40” Arch Pane Doors, Black
40” Arch Pane Doors, Textured Iron
40” Arch Pane Doors, Satin Pewter
40” Arch Pane Doors, Antique Brass
SD40TI
SD40SP
SD40AB
40” Sq. Doors, Textured Iron
40” Sq. Doors, Satin Pewter
40” Sq. Doors, Antique Brass
SQUARE PANE DESIGN KITS
40” Sq. Pane Doors, Black
40” Sq. Pane Doors, Textured Iron
40” Sq. Pane Doors, Satin Pewter
40” Sq. Pane Doors, Antique Brass
H0966
H0967
H0968
H0969
SPD40C
SPD40TI
SPD40SP
SPD40AB
H0934
H0935
H0936
H0937
APD40C
APD40TI
APD40SP
APD40AB
EDVST
EDVPF
EDVCR
EDVCL
EDVST
EDVPF
EDVCR
EDVCL
23
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORY COMPONENTS CONTINUED
Style View Doors Continued -
Style View Doors also come in a Tall Arch Pane Design. Two distinctive grille kits, the “Crescents” and “Sunrise” design, are
also offered seperately. They are easy to install and will not require hardware to attach them to the standard glass door frame.
The door includes heavy duty magnet door latches and functional twin-pane doors.
TALL ARCH PANE DOORS
Cat. No.
H3529
Model
TAPD40C
TAPD40SP
Description
Model Series
EDVST
40” Arch Pane Doors, Black
40” Arch Pane Doors, Satin Pewter
Tall Arch Pane Door
H3531
Sunrise Grille Kits
Crescents Grille Kits
“Crescents” Grille Kits
“Sunrise” Grille Kits
Cat. No.
Model
Description
Model Series
EDVST
Cat. No.
Model
Description
Model Series
EDVST
H3549 CUGK40C
40” Crescents Upper Grille Kit, Black
H3573 SUGK40C
40” Sunrise Upper Grille Kit, Black
CUGK40SP 40” Crescents Upper Grille Kit, Satin Pewter
H3551
SUGK40SP 40” Sunrise Upper Grille Kit, Satin Pewter
H3575
H3553 CLGK40C
40” Crescents Lower Grille Kit, Black
H3577 SLGK40C
40” Sunrise Lower Grille Kit, Black
H3555
CLGK40SP 40” Crescents Lower Grille Kit, Satin Pewter
H3579
SLGK40SP 40” Sunrise Lower Grille Kit, Satin Pewter
Arch Screen Panel Kit
40" Decorative Arch Screen Panel Kit - Textured Iron
Model No.
DASPK40TI
Catalog No.
H3594
This screen panel kit can be installed on the glass enclosure panel to prevent direct contact with
the hot glass surface. The panel kit adds a new design choice with a handsome textured iron
finish. The screen panel kit cannot be used in conjunction with either of the arch door kits or
door frame kits.
24
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE SCHEDULE
Annually (Before the onset of the Burning Season)
MAINTENANCE TASK
ACCOMPLISHING PERSON
PROCEDURE
Inspecting/Cleaning Burner, Logs
and Controls
Qualified Service Technician
Inspect valve and ensure it is properly operating. Check piping
for leaks. Vacuum the control compartment, fireplace logs and
burner area.
Check Flame Patterns and Flame Qualified Service Technician
Height
Refer to Figure 9 on Page 15 and verify the flame pattern and
heightdisplayedbytheapplianceconformstothepicture. Flames
must not impinge on the logs. Ensure flames are steady (not
lifting or floating).
Inspecting/Cleaning Pilot and Burner
Checking Vent System
Qualified Service Technician
Qualified Service Technician
Refer to Figures 11 and 12 on Page 16. Remove any surface
build-up on pilot and burner assembly. Wipe the pilot nozzles,
igniter/flame rod and hood. Ensure the pilot flame engulfs the
flame sensor as shown.
Inspect the vent system at the top and at the base (within the
firebox) for signs of blockage or obstruction. Look for any signs
of dislocation or deterioration of the vent components. Note:
Excessive condensation can cause corrosion of caps, pipe &
fittings (excessive condensation can be caused by long lateral
runs, too many elbows and/or exterior portions of the system
being exposed to cold weather). Also inspect wall straps or
plumbers's tape to ensure it is secure and in place.
Appliance Checkout
Qualified Service Technician
Perform the appropriate appliance checkout procedure detailed
in this manual.
Replacing Rockwool Ember Materials Homeowner/Qualified Service
Technician
Remove old ember materials (rockwool) and vacuum the
rockwool placement area. Place new embers as described in
this document.
Periodically (After the Burning Season)
MAINTENANCE TASK
ACCOMPLISHING PERSON
PROCEDURE
Cleaning Firebox Interior
Homeowner
Carefullyremovelogs,rockwool,volcanicstoneandvermiculite.
Vacuum out interior of the firebox. Clean firebox walls and log
grate. Replace logs, Rockwool and vermiculite as detailed in
this manual.
Check Flame Patterns and Flame Homeowner
Height
Refer to Figure 9 on Page 15 and verify the flame pattern and
heightdisplayedbytheapplianceconformstothepicture.Flames
must not impinge on the logs.
Checking Vent System
Homeowner
Inspect the vent system at the top and at the base (within the
firebox) for signs of blockage or obstruction. Look for any signs
of dislocation of the vent components.
Cleaning Front Glass Enclosure Panel Homeowner
Clean as necessary following the directions provided in this
manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS
WHILE HOT.
25
I
Download from Www.Somanuals.com. All Manuals Search And Download.
LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INjURY OR LOSS OF LIFE.
A. This appliance has a pilot which must be lit with a piezo
igniter. When lighting the pilot, follow these instructions
exactly.
•
•
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s
phone.
•
If your gas supplier cannot be reached, call the fire depart-
ment.
B. BEFORE OPERATING smell all around the appliance area for
gas. Ensure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
do not try to repair it, call a qualified service technician. Force
or attempted repair may result in a fire or an explosion.
WHAT TO DO IF YOU SMELL GAS
•
•
•
•
Extinguish any open flame.
Open windows.
Do not light any appliance.
Do not touch any electrical switches.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
6. Wait five (5) minutes to clear out any gas. If you then smell gas,
STOP! Follow “B” in the safety information above on this page. If you
do not smell gas, go to the next step.
2. Access the lower control compartment.
3. Turn OFF/ON switch to “OFF” (and remote wall switch, if appli-
7. Push in gas control knob slightly and turn counterclockwise
cable).
to “PILOT.”
4. Verify main line shut-off valve is open.
8. Push in control knob all the way and hold in. Immediately light the
pilot by triggering the spark igniter (pushing the button) until pilot
lights. Continue to hold the control knob in for about 1 1/2 minutes
after the pilot is lit. Release knob and it will pop back up. Pilot should
remain lit. If it goes out, repeat steps 5 through 8.
5. Push in gas control knob slightly and turn clockwise
to “OFF.”
SIT Millivolt Gas Valve
•
If knob does not pop up when released, stop
and immediately call your service technician
or gas supplier.
I N
O U T
TP/TH
TP
H
F
O
P
I
L
O
W
T
TH
•
If pilot will not stay lit after several tries,
turn the control knob to “OFF” and call
your service technician or gas supplier.
O
N
I
T O
Millivolt Pilot
- LO / HI +
GAS CONTROL
KNOB
9. Turn gas control knob counterclockwise
BURNER
OFF/ON SWITCH
PIEZO
IGNITER
to “ON.”
10. Close lower control compartment.
Note: Knob cannot be turned from “PILOT” to “OFF”
unless the knob is pushed in slightly. Do not force.
TO TURN OFF GAS TO APPLIANCE
1. Turn remote wall switch “OFF.” The pilot will remain lit for
4. Depress gas control knob slightly and turn clockwise
normal service.
to “OFF.” Do not force.
2. For complete shutdown, turn remote wall switch to “OFF.”
5. Close lower control compartment.
3. Access the lower control compartment.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE
AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS à LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU
UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.
•
•
Appelez immédiatement votre compagnie de gaz en utilisant le télé-
phone du voisin.
A. Cet appareil est muni d’une veilleuse qui doit être allumée avec un
allumeur piézo-électrique. Lorsque vous allumez la veilleuse, suivre
exactement ces instructions.
B. AVANTL’ALLUMAGE:Ensurez-vousquevousnedétectezaucuneodeur
de gaz autour de l’apareil ainsi que près du sol; certains gaz, étant plus
lourds que l’air, descendent au niveau du sol.
S’il vous est impossible de contacter votre compagnie de gaz, appelez
le service des incendies.
C. N’utilisez que votre main pour manipuler le bouton de réglage du gaz.
N’utilisez jamais d’outils. Si le bouton refuse de tourner ou de bouger,
n’essayez pas de le réparer. Communiquez immédiatement avec un
technicien de service qualifié. Toute tentative pour le forcer ou le
réparer, risquerait de provoquer un incendie ou une explosion.
D. Ne vous servez pas de cet appareil si l’un de ses éléments a été
immergé dans l’eau. Appelez immédiatement un technicien compétent
pour faire inspecter l’appareil et remplacer toute pièce du système de
réglage ou commande du gaz qui a été sous l’eau.
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE ODEUR
DE GAZ:
•
•
•
•
•
Éteignez toute flamme visible.
Ouvrez les fenêtres.
N’allumez aucun appareil.
Ne touchez à aucun commutateur électrique.
Ne vous servez d’aucun téléphone dans votre édifice.
INSTRUCTIONS D'ALLUMAGE
8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.
Allumez immédiatement la veilleuse en déclenchant l’allume-gaz
à étincelle (en poussant le bouton) jusqu’à ce que la veilleuse
s’enflamme. Continuez de tenir le bouton de réglage enfoncé
pendant environ 90 secondes après l’allumage de la veilleuse.
Relâchez le bouton et il sortira subitement. La veilleuse devrait
rester allumée. Si elle s’éteint, répétez les étapes 5 à 8 inclusive-
ment.
1. ARRÊTEZ! Lisez les consignes de sécurité au verso de cette plaque.
2. Ouvrez le compartiment de contrôle du bas.
3. Tournez l’interrupteur mural à la position d’arrêt “OFF”.
4. Ensurez-vous que la soupape d’arrêt de la canalisation principale est
ouverte.
5. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
le sens des aiguilles d’une montre
d’arrêt “OFF”.
jusqu’à la position
SIT Vanne Gaz Millivolt
• Si le bouton ne sort pas automatiquement après avoir été relâché,
arrêtez immédiatement et téléphonez à votre technicien de service
ou à votre fournisseur de gaz.
I N
O U T
TP/TH
TP
H
F
O
P
I
L
O
W
T
• Si la veilleuse refuse de rester allumée après plusieurs tentatives,
tournez le bouton de réglage jusqu’à sa position d’arrêt “OFF” et
téléphonez à votre technicien de service ou à votre fournisseur de
gaz.
TH
O
N
I
T O
- LO / HI + (COMMANDE
DE TAILLE DE FLAMME)
BOUTON DE RÉGLAGE DU GAZ
ALLUMEUR
9. Tournez le bouton de réglage du gaz en sens inverse des aiguilles
Interrupteur
(OFF/ON)
d’une montre
jusqu’à sa position de marche “ON”.
10. Fermez le compartiment de contrôle du bas.
11. Au besoin, rebrancher l’appareil au
courant électrique et remettre
Millivolt Pilot
l’interrupteur du brûleur principal
à la position “ON” ou régler le
Remarque: Il est impossible de tourner le bouton de “PILOT” à “OFF” à
moins qu’il ne soit légèrement enfoncé. Ne le forcez pas.
0thermostat à la température désirée.
12. Si l’appareil ne fonctionne pas,
suivre les instructions intitulées
“Pour fermer le gaz qui alimente
l’appareil” et appeler un technicien
ou le fournisseur de gaz.
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous décelez
une odeur de gaz, ARRÊTEZ ! Retournez au point “B” des consignes
de sécurité au verso de cette plaque. Si vous ne remarquez aucune
odeur de gaz, passez à l’étape suivante.
7. Enfoncez légèrement le bouton de réglage du gaz et tournez-le en
sens inverse des aiguilles d’une montre jusqu’à la position de veil-
leuse
“PILOT”.
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL
1. Tournez l’interrupteur mural à la position d’arrêt “OFF”. La veilleuse
4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans
restera allumée jusqu’au retour du service normal.
le sens des aiguilles d’une montre
jusqu’à la position
d’arrêt “OFF”. Ne forcez pas le bouton.
2. Pour une fermeture complète, tournez l’interrupteur mural à la posi-
tion d’arrêt “OFF”.
5. Fermez le compartiment de contrôle du bas.
3. Ouvrez le compartiment de contrôle du bas.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
LIGHTING INSTRUCTIONS — ELECTRONIC
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE, PERSONAL INjURY OR LOSS OF LIFE.
A. When lighting the appliance, follow these instructions
• Immediately call your gas supplier from a neighbor’s
exactly.
phone.
• If your gas supplier cannot be reached, call the fire
B. BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
department.
C. Use only your hand to turn the gas control lever. Never
use tools. If the lever will not turn by hand, do not try
to repair it, call a qualified service technician. Force or
attempted repair may result in a fire or an explosion.
WHAT TO DO IF YOU SMELL GAS
• Extinguish any open flame.
• Open windows.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been under
water.
• Do not light any appliance.
• Do not touch any electrical switches.
• Do not use any phone in your building.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Turn remote wall switch to “OFF.”
5. Turn the ON/OFF switch to “OFF”. Do not force.
6. Wait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow “B” in the safety information
above on this page. If you do not smell gas, go to the
next step.
3. Open lower control compartment door.
4. Verify main line shut-off valve is open.
7. Turn the ON/OFF switch to “ON”. Do not force.
ON/OFF Switch
8. Turn “ON” all electrical power to appliance (remote wall
switch).
9. Close lower control compartment door.
TO SHUT OFF
1. Turn off all electrical power to the appliance (remote wall
switch).
Front View
TO TURN OFF GAS TO APPLIANCE
1. For complete shut-down, turn remote wall switch to
3. Turn the ON/OFF switch to “OFF”. Do not force.
4. Close the main line shut-off valve.
“OFF.”
2. Open lower control compartment door.
5. Close lower control compartment door.
28
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTRUCTIONS D’ALLUMAGE — ELECTRONIC
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE
AVERTISSEMENT:SIVOUSNESUIVEZPASCESINSTRUCTIONSàLALETTRE,ILPOURRAITS’ENSUIVREUNINCENDIEOUUNE
EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.
A. Lorsquevousallumezl’appareil,suivezexactementcesinstruc-
•
•
Appelez immédiatementvotre compagnie degazenutilisant
le téléphone du voisin.
tions.
S’il vous est impossible de contacter votre compagnie de
gaz, appelez le service des incendies.
B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez
aucune odeur de gaz autour de l’apareil ainsi que près du sol;
certains gaz, étant plus lourds que l’air, descendent au niveau
du sol.
C. N’utilisez que votre main pour manipuler linterrupteur “ON/
OFF” de la valve à gaz. N’utilisez jamais d’outils. Si
l’interrupteur ne bouge pas manuellement, n’essayez pas de le
réparer. Communiquez immèdiatement avec un technicien de
service qualifié. Toute tentative pour forcer l’interrupteur ou le
réparer, risquerait de provoquer un incendie ou une explosion.
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE
ODEUR DE GAZ
•
•
•
•
•
Éteignez toute flamme visible.
Ouvrez les fenêtres.
D. Ne vous servez pas de cet appareil si l’un de ses éléments a
été immergé dans l’eau. Appelez immédiatement un technicien
compétent pour faire inspecter l’appareil et remplacer toute
pièce du système de réglage ou commande du gaz qui a été
sous l’eau.
N’allumez aucun appareil.
Ne touchez à aucun commutateur électrique.
Ne vous servez d’aucun téléphone dans votre édifice.
INSTRUCTIONS D’ALLUMAGE
1. ARRÊTEZ ! Lisez les consignes de sécurité au verso de cette
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous
décelez une odeur de gaz ARRÊTEZ ! Retournez au point “B”
des consignes de sécurité au verso de cette plaque. Si vous ne
remarquez aucune odeur de gaz, passez à l’étape suivante.
plaque.
2. Tournez l’interrupteur mural à la position d’arrêt “OFF”.
7. Tournez la manette de réglage du gaz jusqu’à la position de
3. Ouvrez la porte du compartiment de contrôle du bas.
marche “ON”. Ne la forcez pas.
4. Assurez-vousquelasoupaped’arrêtdelacanalisationprincipale
8. Ouvrez le courant électrique (“ON”) qui alimente l’appareil
est ouverte.
(interrupteur mural).
9. Fermez la porte du compartiment de contrôle du bas.
5. Tournez la manette de réglage du gaz à la position d’arrêt “OFF”.
Interrupteur
ON/OFF
10. Au besoin, rebrancher l’apareil au courant électrique et
remettre l’interrupteur principal du brûleur à la position “ON”
ou régler le thermostat à la température désirée.
11. Si l’appareil ne se met pas en marche, suivre les instruc-
tions intitulées “Pour fermer le gaz qui alimente l’appareil” et
appeler un technicien ou le fournisseur de gaz.
POUR ÉTEINDRE L’APPAREIL
1. Coupez tout le courant électrique qui alimente l’appareil (inter-
Vue de face
rupteur mural).
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL
1. Pour une fermeture complète, tournez l’interrupteur mural à la
3. Tournez la manette de réglage du gaz à la position d’arrêt “OFF”.
position d’arrêt “OFF”.
Ne la forcez pas.
2. Ouvrez la porte du compartiment de contrôle du bas.
4. Fermez la soupape d’arrêt de la canalisation principale.
5. Fermez la porte du compartiment de contrôle du bas.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM
Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in
the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
POSSIBLE CAUSES
SYMPTOM
CORRECTIVE ACTION
1. Spark ignitor will not light
pilot after repeated triggering
of ignitor button.
Checkforsparkatelectrodeandpilot;ifnosparkandelectrode
wire is properly connected, replace ignitor.
A. Defective ignitor
(no spark at electrode).
Using a match, light pilot. If pilot lights, turn off pilot and trig-
ger the ignitor button again. If pilot lights, an improper gas
mixture caused the bad lighting and a longer purge period is
recommended.Ifpilotwillnotlight–checkgapatelectrodeand
pilot – should be 1/8" to have a strong spark. If gap measures
1/8", replace pilot (Figure 11 on page 16).
B. Defective or misaligned electrode
at pilot (spark at electrode).
C. Gas supply pressure errant.
Check inlet gas pressure. It should be within the limits as
marked on the rating plate.
D. Pilot orifice plugged.
Clean or replace pilot orifice.
Check pilot flame, it must impinge on thermocouple (Figure
11 on page 16) Clean and/or adjust pilot for maximum flame
impingement on thermocouple. Ensure that the connection
between the valve and thermocouple are tight and secure.
2. Pilot will not stay lit after
carefully following the light-
ing instructions.
A. Defective pilot generator
(thermocouple).
3. Pilot burning, no gas to
burner, Valve knob “ON,”
Wall Switch “ON.”
A. Wall switch or wires defective.
Check wall switch and wires for proper connections. Jumper
wire across terminals at wall switch, if burner comes on, re-
place defective wall switch. If okay, jumper wires across wall
switch wires at valve, if burner comes on, wires are faulty or
connections are bad.
Check thermopile with millivolt meter. Take reading at thermo-
pileterminalsofgasvalve.Shouldread325millivoltsminimum
with optional wall switch “OFF.” Replace faulty thermopile if
reading is below specified minimum.
B. Thermopile may not be generating
sufficient millivoltage.
C. Plugged burner orifice.
Check burner orifice for stoppage and remove.
Clean and/or adjust pilot flame for maximum flame impinge-
ment on thermocouple (Figure 11 on page 16).
4. Frequent pilot/burner outage
A. Pilot flame may be too low or
blowing (high) causing the pilot/
valve safety to drop out.
problem.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM
Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in
the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE ACTION
1. Burner will not light.
A. Faulty Valve System.
See Below.
B. “OFF/ON” or wall switch
Disconnect the two black wires from the wire nuts. Test switch(s) for continu-
ity with a multimeter. If continuity is not indicated, switch(s) is defective and
must be replaced.
defective.
Note: Before replacing “OFF/ON” switch, be sure to check wiring for loose
connections or broken wires and repair as needed.
2. Burners come “ON” but
A. Burner orifice plugged.
Check main burner orifice(s) for stoppage. Clean or replace.
Check vent system for obstructions.
go “OFF.”
B. Obstructed vent system.
START
CHECK
• Check For Proper Voltage At Control Harness
(See Insert A). Voltage Should Be 24V
Between Thermostat Or Pressure Switch
• Turn Off Gas Supply
• Line Voltage Power
• Low Voltage Transformer
• Limit Controller
• Thermostat
NO
• Assure Valve Switch Is In ON Position
• Disconnect Control Harness
• Set Thermostat To Call For Heat
And 24V Common And 24V Hot.
2
• Wiring
YES
• Plug Control Harness Into Valve. Wait For
Internal Check Delay.
• With Pilot Burner Cable Connected, Measure
Voltage At Valve HSI Element Output. 24V
Nominal. (See Insert B)
NO
NO
• Igniter Warms Up And Glows Red.
• Replace Valve.
Insert A
End View Of
Control Harness
Connector
1
2
24 Volt Hot
YES
24 Volt
Common
1
YES
• Replace Igniter/Flame Rod Assembly.
YES
24 Volt
Switched
NO
NO
• Check That Pilot Gas Is Flowing. Wait To
Assure Plot Gas Tubing Is Purged. Recycle
Call For Heat If Necessary.
• Replace Valve.
• Turn On Gas Supply. • Pilot Burner Lights.
Check For Damaged Or Missing Terminals
In Connector
YES
• Measure Voltage Between 24V Hot And 24V Common
Leads To Valve Control. Must Measure At Least 19.5
VAC With Igniter Powered (See Insert A). To Identify
Proper Lead, This Check Must Be Done With The
Valve Control Connected And Igniter Powered.
NO
• Check Transformer And
Line Volt Supply.
Insert B
YES
Igniter Terminals
YES
• Replace Pilot Assembly.
• Check That Pilot Flame Makes Good Contact With
Pilot Burner Flame Rod.
NO
• Check For Good Electrical Connection Through The
Pilot Tubing.
• Main Valve Opens And Main Burner Lights.
• If Both Of The Above Are Good, Replace Igniter/Flame
Rod Assembly.
YES
YES
• Cycle Thermostat Off And Back On.
• System Is Okay.
Igniter Will Cycle Off And Back On Once During
When Measured Voltage At Connections, Use
Care To Assure Terminals Are Not Damaged.
NO
1
2
• Main Burner Lights.
• Replace Valve.
The 90 Second Ignition Trial. All Voltage
Measurements Must Be Taken While The Igniter
Is Powered.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS LIST
Natural and Propane
No. DESCRIPTION
Part No.
Qty.
Qty.
Qty.
Qty.
EDVST
EDVPF
EDVCL
EDVCR
1a Upper Radiant, Black - 24 in.
1b Upper Radiant, Black - 40 in.
2a Hood, Black - 24 in.
H3723
H3722
98K95
97K52
H3743
H3741
H3725
H3724
H3731
H3729
H3733
H3732
12L15
55M04
H3358
H3876
55M42
19L51
43K85
42M80
H3386
H3385
H3388
H3387
69L21
69L31
80L41
H3707
93L32
none
1
2
1
1
1
1
2
none
1
1
1
2b Hood, Black - 40 in.
2
2
1
1
3a Upper Bustle, Black - 24 in.
3b Upper Bustle, Black - 40 in.
4a Glass Enclosure Assembly - 24 in.
4b Glass Enclosure Assembly - 40 in.
5a Lower Bustle, Black - 24 in.
5b Lower Bustle, Black - 40 in.
6a Lower Radiant Assembly, Black - 24 in.
6b Lower Radiant Assembly, Black - 40 in.
none
1
1
1
2
2
1
1
none
1
1
1
2
2
1
1
none
1
1
1
2
2
1
1
none
1
1
1
2
2
1
1
7
8
9
Nameplate (Brand)
Log Set
2
2
1
1
1
1
1
1
Grate Assembly
1
1
1
1
10 Magnet, Radiant Panel
11 Burner Assembly
2
4
3
3
1
1
1
1
12 Gasket, Burner Tray Mounting
13 Gasket, Venturi Tube Mounting
14 Venturi Tube Arm
1
1
1
1
1
1
1
1
1
1
1
1
Millivolt
15a
none
1
1
none
none
1
Modesty Panel - PF, CL
15b
Electronic
none
1
1
15c
Millivolt
1
1
4
2
1
1
1
none
none
6
none
none
4
Modesty Panel - ST, CR
15d
Electronic
1
16 Latch, Glass Enclosure Panel
17 Magnet, Latch, Spring-Loaded
18 Switch, Rocker
4
2
1
1
1
1
1
19 Air Shutter Adjustment Rod
20 Flex Line Gas Connector
1
1
1
1
1
1
Note: Ordering information for Volcanic Stone, Glowing Embers and Touch-up Paint can be found on Page 19.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS LIST CONTINUED
GAS CONTROLS — SIT MILLIVOLT
Natural
Propane
Part No.
No.
DESCRIPTION
Part No.
43K07
10K86
69L17
60J79
74L57
74L56
74L58
21L81
31L22
Qty.
1
Qty.
1
30.
31.
32.
33.
34.
35.
36.
37.
38.
Gas Valve - SIT
Piezo Igniter
88J53
10K86
69L18
60J79
74L57
74L56
74L58
21L82
31L22
1
1
Pilot Assembly
Pilot Generator
Thermocouple
Pilot Tube
1
1
1
1
1
1
1
1
Electrode And Cable
Orifice
1
1
1
1
Sticker (Modesty Panel)
1
1
GAS CONTROLS — HONEYWELL ELECTRONIC
Natural
No.
DESCRIPTION
Part No.
62L18
62L14
42J32
87L54
21L81
69L50
H3720
Qty.
1
40.
41.
42.
43.
44.
45.
46.
Gas Valve - Honeywell
Pilot Assembly
Transformer
1
1
Ignitor Assembly (Kit)
Orifice
1
1
Sticker (Modesty Panel)
Pilot Tube
1
1
Contact an Authorized Lennox Hearth Products dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts
can result in poor performance and safety hazards.
WARNING
AVERTISSEMENT
Failure to position the parts in accordance with these
diagrams or failure to use only parts specifically
approved with this appliance may result in property
damage or personal injury.
Risque de dommages ou de blessures si les pièces
ne sont pas installées conformément à ces schémas
et ou si des pièces autres que celles spécifiquement
approuvées avec cet appareil sont utilisées.
33
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS
EDVPF Shown - see table on page 30 and 31
for replacement parts applicable to
EDVST, EDVCR and EDVCL
Cabinet
Firebox
8
17
15a
15b
16
12
13
10
9
31
38
45
33
34
18
14
36
1b
2b
32
3b
11
20
4b
19
35
30
5b
37
44
6b
7
42
1a
2a
40
3a
4a
43
5a
6a
41
46
34
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design,
materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2003 Lennox Hearth Products
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
P/N 875022M REV. F 01/2011
Download from Www.Somanuals.com. All Manuals Search And Download.
|