Lennox Hearth Indoor Fireplace 875022M User Manual

CARE AND OPERATION INSTRUCTIONS  
EDV Direct-Vent  
Gas Fireplaces  
P/N 875022M Rev. F 01/2011  
MODELS  
This manual is part of a set of two supporting this product.  
Refer to P/N 850018M for Installation Instructions.  
Ce manuel est disponible en francais, simplement  
en faire la demande. Numéro de la pièce 875022CF.  
MILLIVOLT:  
ELECTRONIC:  
EDVSTNM-B  
EDVCRNM-B  
EDVCRPM-B  
EDVCLNM-B  
EDVCLPM-B  
EDVSTNE-B  
EDVPFNE-B  
EDVCRNE-B  
EDVCLNE-B  
EDVSTPM-B  
EDVPFNM-B  
EDVPFPM-B  
WHAT'S INSIDE  
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
FREE Safety Guard Offer (Protects Against Burns) . . . . . . . . . . . . . 2  
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . 5  
Portland  
US  
OTL Report No. 116-F-04-5  
[EN FRANÇAIS] Linformation de sûreté importante . . . . . . . . . . . . 3–4  
Apposition des mises en garde relatives à la sécurité d’utilisation . . . 5  
[EN ESPAÑOL] Información importante de seguridad. . . . . . . . . . . . 3–4  
Colocación de advertencias de seguridad en operación . . . . . . . . . . 5  
Wait...  
DON’T  
INSTALLER: Leave this manual with the appliance.  
CONSUMER: Retain this manual for future reference.  
INSTALLATEUR : Laissez cette notice avec l'appareil.  
THROW  
P
R
O
T
E
C
T
S
IT AWAY!  
This manual contains  
important operating  
and safety  
A
G
A
I
N
S
T
B
U
R
N
S
CONSOMMATEUR : Conservez cette notice pour consultation ultérieure.  
information.  
/
/
WARNING AVERTISSEMENT AVISO  
HOT GLASS WILL CAUSE  
BURNS.  
UNE SURFACE VITRÉE CHAUDE  
PEUT CAUSER DES BRÛLURES.  
LAISSER REFROIDIR LA SURFACE  
VITRÉE AVANT D'Y TOUCHER.  
EL VIDRIO CALIENTE  
CAUSARÁ QUEMADURAS.  
USTED DEBE NUNCA  
DO NOT TOUCH GLASS  
UNTIL COOLED.  
TOCAR EL VIDRIO CALIENTE.  
NEVER ALLOW CHILDREN  
TO TOUCH GLASS.  
NE PERMETTEZ JAMAIS À UN ENFANT LOS NIÑOS DEBEN NUNCA  
DE TOUCHER LA SURFACE VITRÉE.  
TOCAR EL VIDRIO.  
WARNING: If the information in these instructions  
is not followed exactly, a fire or explosion may  
result, causing property damage, personal injury,  
or death.  
AVERTISSEMENT : Assurez-vous de bien suivre les  
instructions données dans cette notice pour réduire au  
minimum le risque d’incindie ou d’explosion ou pour  
éviter tout dommage matériel, toute blessure ou la mort.  
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs  
ou liquides inflammables dans le voisinage de cet appareil  
ou de tout autre appareil.  
-
vapors and liquids in the vicinity of this or any other  
appliance.  
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :  
• Ne pas tenter d’allumer d’appareil.  
- WHAT TO DO IF YOU SMELL GAS:  
• Do not try to light any appliance.  
• Do not touch any electrical switch; do not use any  
phone in your building.  
• Immediately call your gas supplier from a  
neighbor’s phone. Follow the gas supplier’s  
instructions.  
• Ne touchez à aucan interrupteur. Ne pas vous servir des  
téléphones se trouvant dans le bâtiment où vous trouvez.  
• Appelez immédiatement votre fournisseur de gaz depuis  
un voisin. Suivez les instructions du fournisseur.  
• Si vous ne pouvez rejoindre le fournisseur de gaz,  
appelez le service des incindies.  
- Linstallation et l’entretien doivent être assurés par un  
installateur ou un service d’entretien qualifié ou par le  
fournisseur de gaz.  
department.  
- Installation and service must be performed by a  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[FRENCH]  
[SPANISH]  
La sécurité et  
votre foyer  
Seguridad y  
su chimenea  
Toutes les parties de votre foyer  
Lennox Hearth Products deviennent  
EXTRÊMEMENT CHAUDES !  
¡Todas las partes de la chimenea  
Lennox Hearth Products se ponen  
MUY CALIENTES!  
Afin d'éviter de vous brûler gravement ou de  
vous blesser, installez une grille ou une barrière  
physique pour empêcher tout contact direct  
avec la vitre.  
Instale una malla o barrera física para evitar  
el contacto directo con el vidrio y prevenir  
las quemaduras y lesiones graves.  
Ver los detalles a la izquierda para ordenar  
un Lennox® SAFETY GUARD GRATIS  
para su chimenea.  
Pour commander un PANNEAU DE PROTECTION  
Lennox® GRATUIT pour votre foyer, consultez  
les détails dans la partie gauche.  
Siga las instrucciones de seguridad a  
continuación y asegúrese de que todos  
en su hogar sepan acerca de este peligro  
de quemadura:  
Suivez les instructions de sécurité ci-dessous  
et veillez à ce que tous les membres de votre  
famille soient conscients du danger de brûlure  
encouru :  
¡Las superficies de la chimenea se ponen  
Les surfaces de votre foyer deviennent  
MUY CALIENTES!  
EXTRÊMEMENT CHAUDES !  
El vidrio delante de la chimenea alcanza  
temperaturas EXTREMADAMENTE ALTAS y  
puede causar quemaduras graves si se toca.  
La vitre située à l'avant du foyer  
atteint des températures  
EXTRÊMEMENT ÉLEVÉES et peut causer  
de graves blessures en cas de contact.  
Mantenga a los niños alejados de la  
chimenea en funcionamiento. Supervise  
en forma cercana a los niños en cualquier  
cuarto donde haya una chimenea  
funcionando para impedir el contacto  
con el vidrio.  
Tenez les enfants à l'écart du foyer lorsqu'il  
fonctionne. Surveillez attentivement  
les enfants dans les pièces où un foyer  
est utilisé afin d'éviter qu'ils ne soient  
en contact avec la vitre.  
Mantenga la ropa, mobiliario, gasolina  
y otros líquidos inflamables alejados  
de la chimenea.  
Tenez tous les vêtements, les  
meubles, l'essence et tout autre  
liquide inflammable à l'écart du foyer.  
Aún después de haber apagado el gas,  
las superficies de la chimenea permanecen  
extremadamente calientes.  
Même après fermeture du gaz, les surfaces  
du foyer restent extrêmement chaudes.  
Veillez à coller les Étiquettes de mise en garde  
relatives à la sécurité d'utilisation à l'endroit  
où vous utilisez le foyer, pour rappeler à tous les  
utilisateurs les dangers liés aux températures  
élevées (voir page 5).  
Asegúrese de colocar las Etiquetas de  
advertencia de seguridad de operación en  
el lugar donde enciende la chimenea, para  
que todos recuerden los peligros asociados  
con las altas temperaturas (ver la página 5).  
Lisez la section Informations importantes  
Lea la Información importante de seguridad  
relatives à la sécurité, page 4.  
en la página 4.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Safety Information  
L'information de sûreté importante  
1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal  
en verre n’est pas en place, est craqué ou brisé. Confiez le  
remplacement du panneau à un technicien agréé  
1. WARNING: Do not operate appliance with the glass front  
removed, cracked or broken. Replacement of the glass  
should be done by a licensed or qualified service person .  
2. Ne pas utiliser cet appareil s’il a été plongé, même partiellement,  
dans l’eau. Appeler un technicien qualifié pour inspecter  
l’appareil et remplacer toute partie du système de commande  
et toute commande qui a été plongée dans l’eau.  
2. Do not use this appliance if any part has been under water.  
Immediately call a qualified service technician to inspect  
the appliance and to replace any part of the control system  
and any gas control which has been under water.  
3. En raison des températures élevées, l’appareil devrait être  
installé dans un endroit où il y a peu de circulation et loin du  
mobilier et des tentures.  
3. Due to high temperatures, the appliance should be located  
out of traffic and away from furniture and draperies.  
4. Les enfants et les adultes devraient être informés des dangers  
que posent les températures de surface élevées et se tenir à  
distance afin d’éviter des brûlures ou que leurs vêtements ne  
s’enflamment.  
5. On ne devrait pas placer de vêtements ni d’autres matières  
inflammables sur l’appareil ni à proximité.  
4. Children and adults should be alerted to the hazards of  
high surface temperature and should stay away to avoid  
burns or clothing ignition.  
5. Clothing or other flammable material should not be placed  
on or near the appliance.  
6. Les jeunes enfants devraient être surveillés étroitement lorsqu’ils  
se trouvent dans la même pièce que l’appareil. Les tout petits,  
les jeunes enfants ou les adultes peuvent subir des brûlures s’ils  
viennent en contact avec la surface chaude. Il est recommandé  
d’installer une barrière physique si des personnes à risques  
habitent la maison. Pour empêcher l’accès à un foyer ou à un  
poêle, installez une barrière de sécurité ; cette mesure empêchera  
les tout petits, les jeunes enfants et toute autre personne à risque  
d’avoir accès à la pièce et aux surfaces chaudes.  
6. Young children should be carefully supervised when they  
are in the same room as the appliance. Toddlers, young  
children, and others may be susceptible to accidental  
contact burns. A physical barrier is recommended if there  
are at-risk individuals in the house. To restrict access to a  
fireplace or stove, install an adjustable safety gate to keep  
toddlers, young children, and other at-risk individuals out  
of the room and away from hot surfaces.  
7. Any safety screen or guard removed for servicing an  
appliance must be replaced prior to operating the  
appliance.  
7. Tout écran ou protecteur retiré pour permettre l’entretien de  
l’appareil doit être remis en place avant de mettre l’appareil en  
marche.  
8. Linstallation et la réparation devrait être confiées à un technicien  
qualifié. Lappareil devrait faire l’objet d’une inspection par un  
technicien professionnel avant d’être utilisé et au moins une  
fois l’an par la suite. Des nettoyages plus fréquents peuvent  
être nécessaires si les tapis, la literie, et cetera produisent  
une quantité importante de poussière. Il est essentiel que les  
compartiments abritant les commandes, les brûleurs et les  
conduits de circulation d’air de l’appareil soient tenus propres.  
Voyez les instructions d’entretien à la page 10.  
8. Installation and repair should be done by a qualified  
service person. The appliance should be inspected  
before use and at least annually by a professional service  
person. More frequent cleaning may be required due to  
excessive lint from carpeting, bedding material, et cetera.  
It is imperative that control compartments, burners, and  
circulating air passageways of the appliance be kept  
clean. See maintenance instructions on page 10.  
[SPANISH]  
6. Se debe supervisar de cerca a los niños cuando estén en el mismo  
cuarto que el artefacto. Los niños pequeños, los jóvenes y otras  
personas pueden ser susceptibles a quemaduras por contacto  
accidental. Se recomienda instalar una barrera física si hay  
personas en riesgo en la casa. Para restringir el acceso a una  
chimenea o estufa, instale una puerta de seguridad ajustable  
para mantener a los niños pequeños, jóvenes y otras personas  
en riesgo fuera del cuarto y lejos de las superficies calientes.  
Información importante de seguridad  
1. ADVERTENCIA: No opere el artefacto con el frente de vidrio quitado,  
agrietado o roto. Un técnico de servicio licenciado o capacitado  
debe reemplazar el vidrio.  
2. No use este artefacto si alguna de sus partes ha estado bajo agua.  
Llame de inmediato a un técnico de servicio calificado para que  
inspeccione el artefacto y reemplace cualquier parte del sistema  
de control y cualquier control de gas que haya estado bajo agua.  
7. Cualquier malla o resguardo de seguridad quitado para dar servicio  
a un artefacto, debe reinstalarse antes de operar el artefacto.  
3. Debido a las altas temperaturas, el artefacto debe situarse fuera  
de las áreas de tráfico y lejos del mobiliario y cortinas.  
8. Una persona de servicio competente debe realizar la instalación y  
reparación. Una persona de servicio profesional debe inspeccionar  
el artefacto antes de usar al menos una vez por año. Se puede  
requerir limpieza más frecuente debido a la pelusa excesiva  
del alfombrado, del material de cobijas, etc. Es imprescindible  
mantener limpios los compartimientos de control, los quemadores  
y los pasajes de circulación del aire del artefacto. Ver las  
instrucciones de mantenimiento en la página 10.  
4. Se debe alertar a los niños y adultos sobre los peligros de  
las altas temperaturas en la superficie y que se mantengan  
alejados para evitar quemaduras o ignición de la ropa.  
5. No debe colocarse ropa u otros materiales inflamables  
sobre y cerca del artefacto.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS  
ATTACHING SAFETY-IN-OPERATION  
WARNINGS  
APPOSITION DES MISES EN GARDE RELATIVES  
à LA SÉCURITÉ D’UTILISATION  
COLOCACIóN DE ADVERTENCIAS DE  
SEGURIDAD EN OPERACIóN  
Yourreplacehasbeenfurnishedwithsafetyinstruc- Votrefoyeraétélivréavecdesétiquettesdesécuritéqui Su chimenea incluye etiquetas de instrucciones  
tion labels that are to be affixed to the operation and doivent être collées à côté des dispositifs de contrôle de seguridad que deben colocarse en el punto de  
control point of the fireplace. A safety instruction du foyer. Une étiquette de sécurité doit être collée sur operación y control de la chimenea. Se debe colocar  
labelshouldbeaffixedtothewallswitchplatewhere la plaque de l’interrupteur contrôlant l’allumage du una etiqueta de instrucciones de seguridad en la placa  
the fireplace is turned on and off (See Figure A) or foyer (voir Figure A) ou sur le thermostat mural (voir del interruptor de pared desde el cual se enciende y se  
wall thermostat (See Figure B) and if used on the Figure B) et, le cas échéant, sur le boîtier de la télé- apaga la chimenea (ver la Figura A) o en el termostato  
remote control handheld transmitter (Figure C). commande(FigureC). Lesmisesengardeauraientdû de pared (ver la Figura B)y en el transmisor de control  
The warnings should already have been put in place êtrecolléesaumomentdel’installationinitialedufoyer. remoto (Figura C)siseusa.Lasadvertenciasyadeben  
when the fireplace initial set-up was completed. Si ce n’est pas le cas, prenez les étiquettes adhésives haberse colocado cuando se completó la instalación  
If they are not affixed at these spots, locate the multilingues fournies avec ces instructions et procédez inicial de la chimenea. Si no están colocadas en estos  
multi-lingual adhesive labels provided with these comme suit:  
lugares,encuentrelasetiquetasadhesivasmultilingües  
instructions and proceed as follows:  
1. Repérez l’interrupteur ou le thermostat mural proporcionadas con estas instrucciones y prosiga de  
qui contrôle le foyer (vérifiez que l’interrupteur la siguiente manera:  
1. Locate the wall switch or wall thermostat that  
controlsthereplace(verifytheswitchoperates  
the fireplace by turning it on and off). Clean the  
wall switch plate or wall thermostat thoroughly  
to remove any dust and oils. Affix the label to  
the surface of the plate of the wall switch that  
controls the fireplace (Figure A) or the wall  
thermostat (Figure B). Choose the language  
primarily spoken in the home.  
contrôle le fonctionnement du foyer en le faisant 1. Identifique el interruptor o el termostato de pared  
basculerdeMarcheàArrêt,etvice-versa). Nettoyez  
soigneusement la plaque murale de l’interrupteur  
ou le thermostat mural pour éliminer la poussière  
et les traces de graisse ou d’huile. Collez l’étiquette  
sur la surface de la plaque de l’interrupteur mural  
qui contrôle le foyer (Figure A) ou du thermostat  
mural (Figure B). Choisissez la langue qui est  
principalement parlée dans la résidence du  
propriétaire.  
quecontrolalachimenea(verifiquequeelinterruptor  
opera la chimenea encendiéndola y apagándola).  
Limpiebienlaplacadelinterruptoroeltermostatode  
pared para quitar el polvo y aceite. Pegue la etiqueta  
enlasuperficiedelaplacadelinterruptorquecontrola  
la chimenea (Figura A) o en el termostato de pared  
(Figura B). Seleccione el idioma que más se habla  
en la casa.  
2. Ifaremotecontrolisusedtocontrolthereplace,  
locate the transmitter and clean it thoroughly  
2. Si se usa un control remoto para controlar la  
chimenea, encuentre el transmisor y límpielo bien  
para quitar el polvo y aceite. Pegue la etiqueta en la  
superficie del transmisor (Figura C). Seleccione el  
idioma que más se habla en la casa.  
to remove any dust and oils. Affix the label to 2. Si une télécommande est utilisée pour contrôler  
the surface of handheld transmitter (Figure C).  
Choose the language primarily spoken in the  
home.  
le foyer, nettoyez la soigneusement pour éliminer  
la poussière et les traces de graisse ou d’huile.  
Collez l’étiquette sur le boîtier de la télécommande  
3. If you are unable to locate the labels, please call  
LennoxHearthProductsoryournearestLennox  
(Figure C). Choisissez la langue qui est principale- 3. Si no puede encontrar las etiquetas, sírvase llamar  
ment parlée dans la résidence du propriétaire.  
a Lennox Hearth Products o al distribuidor de  
Lennox Hearth Products más cercano para recibir  
etiquetasdeinstruccionesdeseguridadadicionales  
gratuitas.  
Hearth Products dealer to receive additional 3. Si vous ne trouvez pas les étiquettes, veuillez  
safety instruction labels free of charge.  
appeler Lennox Hearth Products ou votre distribu-  
teur Lennox Hearth Products local pour recevoir  
gratuitement des étiquettes supplémentaires.  
Cat. No. H8024 Replacement Label Kit  
Juego de etiquetas de repuesto - Nº de cat. H8024  
LENNOX HEARTH PRODUCTS  
1-800-9-LENNOX  
Étiquettes de remplacement, n° cat. H8024  
LENNOX HEARTH PRODUCTS  
1-800-9-LENNOX  
LENNOX HEARTH PRODUCTS  
1-800-9-LENNOX  
Note: English is red text on clear label. French and  
Spanish are white text on black label.  
Nota: La etiqueta en inglés es transparente con texto  
rojo. Las etiquetas en francés y español son negras  
con texto blanco.  
Remarque : Le texte anglais est rouge sur un support  
transparent. Le texte français et espagnol est blanc  
sur un support noir.  
SAFETY LABEL  
DIAGRAMS  
DIAGRAMMES DES ÉTIQUETTES  
DE SÉCURITÉ  
DIAGRAMAS DE ETIQUETAS  
DE SEGURIDAD  
Figure C  
Figure B  
Figure A  
5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
These appliances are designed to  
operate on natural gas or propane  
gas only. The use of other fuels or  
combinations of fuels will degrade the  
performance of this system and may be  
dangerous.  
INSTALLATION, SERVICE,  
AND MAINTENANCE  
General Information  
The fireplace models covered in this manual  
aredirect-ventsealedcombustiongasreplace  
heaters designed for residential application.  
These direct-vent appliances operate with the  
combustion chamber completely isolated from  
the indoor environment.  
IMPORTANT: Improper installation,  
adjustment, alteration, service, or  
maintenance can cause injury or  
property damage. Refer to this manual.  
For assistance or additional information,  
consult a qualified installer, service  
agency or the gas supplier.  
Provide adequate clearances around  
air openings and adequate accessibility  
clearance for service and proper  
operation. Never obstruct the front  
openings of the appliance.  
All air for combustion is brought in from the  
outside and exhaust gases are vented through  
the same direct-vent, co-axial (intake/exhaust)  
vent system.  
Only trim kit(s) supplied by the  
manufacturer shall be used in the  
installation of this appliance.  
Do not use this appliance if any part has  
been under water. Immediately call a  
qualified service technician to inspect the  
appliance and to replace any part of the  
control system and any gas control that  
has been under water.  
The Millivolt appliances have a millivolt gas  
control valve with piezo ignition system. If any  
optional accessories which require electrical  
power are being installed, the electrical power  
must be provided at the time of appliance in-  
stallation.  
Draft relief openings must not be  
covered or blocked.  
These appliances must not be  
connected to a chimney or flue serving a  
separate solid fuel burning appliance.  
WARRANTY  
The Electronic appliances are designed to  
operate on either natural or propane gas. An  
electronic intermittent pilot system provides  
safe, efficient operation. External electrical  
power is required to operate these units.  
Any change to this appliance and/or  
its operating controls is dangerous.  
Improper installation or use of this  
appliance can cause serious injury or  
death from fire, burns, explosion or  
carbon monoxide poisoning.  
Failure to comply with the installation  
and operating instructions provided  
will result in an improperly installed  
and operating appliance, voiding its  
warranty.  
These appliances comply with National Safety  
StandardsandaretestedandlistedbyOMNI-Test  
Laboratories, Inc. (Report No. 116-F-04-5) to  
ANSIZZ21.88(inCanada,CSA-2.33),andCAN/  
CGA-2.17-M91 in both USA and Canada, as  
vented gas fireplace heaters.  
Do not attempt to alter or modify the  
construction of the appliance or its  
components. Any modification or  
alteration may void the warranty,  
certification, and listings of this unit.  
Carbon Monoxide Poisoning: Early  
signs of carbon monoxide poisoning  
are similar to the flu with headaches,  
dizziness and/or nausea. If you  
have these signs, obtain fresh air  
immediately. Turn off the gas supply to  
the appliance and have it serviced by  
a qualified professional, as it may not  
be operating correctly. Some people  
are more affected by carbon monoxide  
than others, including pregnant women,  
people with heart or lung disease or  
anemia, those under the influence of  
alcohol, and those at high altitudes.  
The Installation must conform to local codes  
or, in the absence of local codes, with the  
National Fuel Gas Code, ANSI Z223.1/NFPA  
54-latestedition,ortheNaturalGasandPropane  
Installation Code, CAN/CSA B149.1-latest edi-  
tion. The appliance, when installed, must be  
electrically grounded in accordance with local  
codes or, in the absence of local codes, the  
latest edition of the National Electrical Code,  
ANSI/NFPA70, ortheCanadianElectricalCode,  
CSA C22.1 - latest editions.  
Turn off gas and electrical power to the  
fireplace and allow it to cool before  
cleaning or servicing the appliance.  
Theventterminationishotwhileinopera-  
tion and for a period of time following the  
use of the fireplace. To prevent contact  
withhotsurfaces,werecommendtheuse  
of a termination guard.  
OPERATION  
Do not operate appliance with the glass  
front removed, cracked, or broken.  
Thesereplacesaredesignedassupple-  
mentalheaters.Therefore,itisadvisable  
to have an alternate primary heat source  
when installed in a dwelling.  
These fireplaces are vented gas  
appliances. Do not burn wood or other  
material in these appliances.  
This appliance is only for use with the  
type of gas indicated on rating plate.  
This appliance is not convertible for use  
with other gases, unless a certified kit is  
used.  
These appliances must not be connected  
to a chimney or flue serving a separate  
solid fuel burning appliance.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
BTU Input  
Deration - At higher elevations, the amount  
of BTU fuel value delivered must be reduced  
by either using gas that has been derated by  
the gas company or by changing the burner  
orifice to a smaller size as regulated by the  
local authorities having jurisdiction and by the  
(USA) National Fuel Gas Code NFPA 54/ANSI  
Z223.1 - latest edition or, in Canada, the CAN/  
CSA-B149.1 codes - latest edition.  
Manifold Gas Supply Pressure  
(all models)  
These fireplaces are designed as supplemental  
heaters. Therefore, it is advisable to have an  
alternate primary heat source when installed  
in a dwelling.  
Fuel #  
Low  
High  
Natural (Lo) 2.2" WC  
(Hi) 3.5" WC  
(0.87 kPa)  
Gas  
(0.55 kPa)  
(Lo) 6.3" WC (Hi) 10.0" WC  
(1.57 kPa) (2.49 kPa)  
Millivolt Models - The millivolt appliances are  
manually controlled and feature a spark igniter  
(piezo) that allows the appliance's pilot gas to  
be lit without the use of matches or batteries.  
This system provides continued service in the  
event of a power outage.  
Propane  
Table 3  
Installtheapplianceaccordingtotheregulations  
of the local authorities having jurisdiction and,  
in the USA, the National Fuel Gas Code NFPA  
54 / ANSI Z223.1 - latest edition or, in Canada,  
the CAN/CSA-B149.1 - latest edition.  
Test gauge connections are provided on the  
front of the millivolt and electronic gas control  
valve (identified IN for the inlet and OUT for the  
manifold side). The control valves have a 3/8"  
(10mm) NPT thread inlet and outlet side of the  
valve (refer to Figures 1 and 2).  
Millivoltmodelscomestandardwithamanually-  
modulated gas valve; flame appearance and  
heat output can be controlled at the gas valve.  
The BTU Input for these appliances is shown  
in Table 1.  
Flame breadth, height and width will dimenish  
4% for every 1,000 feet of altitude.  
Propane tanks are at pressures that will cause  
damage to valve components. Verify that the  
tanks have step down regulators to reduce the  
pressure to safe levels.  
Burner Orifice Sizes (all models)  
Electronic Models - Electronic models have a  
fixed rate gas valve. Input of electronic models  
is shown in Table 1.  
Natural  
Propane  
Elevation  
Gas  
Gas  
Feet (meters)  
drill size (inches)  
drill size (inches)  
0-4500  
(0-1372)  
These appliances must be isolated from the  
gas supply piping system (by closing their  
individual manual shut-off valve) during any  
pressure testing of the gas supply piping  
system at test pressures equal to or less  
than 1/2 psig (3.5 kPa).  
(0.125")  
21L81 •  
#41 (0.096")  
*
*
Input (BTU) Gas Valves (all models)  
21L82 •  
All Models  
Fuel  
Type  
Input Rate  
(BTU / HR)  
* Standard size installed at factory  
• Part /Cat. Number  
Table 4  
39,000 high  
31,000 low  
Millivolt  
Natural  
Propane  
Natural  
Burn-in Period  
Theseappliancesandtheirindividualshut-off  
valves must be disconnected from the gas  
supply piping system during any pressure  
testing of that system at pressures greater  
than 1/2 psig (3.5 kPa).  
39,000 high  
31,000 low  
Millivolt  
During the first few fires of this appliance there  
will be some odor due to the curing of the  
paint and burning off of lubricants used in the  
manufacturing process. Depending on your  
use, the burn-in period may take a few hours  
or a few days.  
(if field converted)  
Electronic  
39,000  
39,000  
Electronic  
Propane  
These appliances must not be connected to a  
chimney or flue serving a separate solid fuel  
burning appliance.  
(if field converted)  
KEEP YOUR HOUSE WELL VENTILATED  
DURING THE CURING PROCESS. THE ODOR  
AND HAZE EMITTED DURING THE CURING  
PROCESS CAN BE QUITE NOTICEABLE AND  
MAY SET OFF A SMOKE DETECTOR.  
Table 1  
Orifice Sizes - Sea Level to High Altitude  
(All Models)  
Gas Pressure - All Models  
Tables 2 and 3 show the appliances' inlet and  
manifold gas pressure requirements:  
These appliances are tested and approved for  
installation at elevations of 0-4500 feet (0-1372  
meters)abovesealevelusingthestandardburner  
orifice sizes (marked with an "*" in Table 4 ).  
If an optional blower is installed, Do Not turn  
it on during the Burn-In period.  
Inlet Gas Supply Pressure  
(all models)  
A white film may develop on the glass front  
during the first few fires as part of the curing  
process. The glass should be kept clean during  
thersttwoweeksofusetopreventthelmfrom  
baking on (making it very difficult to remove).  
See Cleaning Glass on Page 10.  
Fuel #  
Minimum  
Maximum  
Forelevationsabove4500feet,contactyourgas  
supplier or qualified service technician.  
4.5" WC  
(1.12 kPa)  
10.5" WC  
(2.61 kPa)  
Natural Gas  
11.0" WC  
(2.74 kPa)  
13.0" WC  
(3.23 kPa)  
Propane  
Table 2  
7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION AND CARE OF YOUR APPLIANCE  
WARNING  
Young children should be carefully supervised when they are in the  
same room as the appliance. Toddlers, young children and others  
may be susceptible to accidental contact burns. A physical barrier is  
recommended if there are at risk individuals in the house. To restrict  
access to a fireplace or stove, install an adjustable safety gate to keep  
toddlers, young children and other at risk individuals out of the room  
and away from hot surfaces.  
Gas Valve  
Control  
Hinge Pin  
ON/OFF  
Switch  
Compartment  
Access panel  
AVERTISSEMENT  
Modesty Panel  
Piezo Ignitor  
Lesjeunesenfantsdevraientêtresurveillésétroitementlorsqu’ilssetrou-  
ventdanslamêmepiècequel’appareil.Lestoutpetits,lesjeunesenfants  
ou les adultes peuvent subir des brûlures s’ils viennent en contact avec  
la surface chaude. Il est recommandé d’installer une barrière physique  
si des personnes à risques habitent la maison. Pour empêcher l’accès  
à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure  
empêchera les tout petits, les jeunes enfants et toute autre personne à  
risque d’avoir accès à la pièce et aux surfaces chaudes.  
Control Compartment Access -  
Millivolt Control Valve Shown  
Figure 1  
Refer to Figure 1 for access to the gas control  
valve. Millivolt appliances will be fitted with the  
gas control valve shown in Figure 2.  
Remove the bottom compartment door by  
sliding the hinge pin, located at the door’s left  
side, to the right until it disengages from the  
left corner post hole. Pull the door diagonally  
to the left, away from the fireplace.  
Gas Controls/Control Compartment  
Access  
Applianceswithelectronicsystemswillbetted  
with the electronic valve shown in Figure 3.  
Familiarize yourself with the gas control valve  
that your appliance uses.  
Thegascontrolscanbefoundbehindthehinged  
drop-down panel.  
To open the hinged drop-down panel, actuate  
the spring loaded magnetic catches securing  
the door. First, gently depress the upper right  
top corner of the panel until the magnet catch  
"pops" the door free. Then, gently pulling the  
panel forward, disengage the left magnet catch  
and allow the panel to swing down to open.  
To ease door closure, depress the catches to  
place them in their retracted position until they  
stay there, then close the door.  
Operation of millivolt and electronic gas con-  
trol systems are different. Before lighting and  
operatingyourappliancedetermineifyouhave  
a millivolt or electronic appliance.  
On millivolt systems, the piezo ignitor, Hi/Lo  
flame adjustment knob, and pilot and main gas  
ON/OFFcontrolknobarelocatedonthemodesty  
panel. On both millivolt and electronic systems  
the gas valve is located behind the modesty  
panel. See Figure 1.  
8
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Variable Flame Height Adjustment  
( Millivolt Appliances only)  
Variable Flame Height Adjustment  
Manifold Pressure Port  
Inlet Pressure Port  
1. All Millivolt appliances are equipped with  
a variable gas control valve. Flame height for  
these models may be adjusted through a range  
betweenxedlowandhighsettings,alternately,  
while the appliance is in operation.  
O U T I N  
F
O
F
T
O
N
Adjust the flame height as desired after lighting  
theappliancebyrotatingthevariableadjustment  
control knob located on the front of the valve  
(refertoFigure 2). (An extensionis providedto  
this knob so that the adjustment may be made  
at the modesty panel.)  
I
Main Gas  
Control Knob  
SIT Millivolt Gas Valve  
Note: The piezo ignitor is located on the modesty panel - refer to Figure 1.  
Figure 2  
2. When lit for the first time, this appliance will  
emitaslightodorforanhourortwo. Thisisdue  
totheburn-inofinternalpaintsandlubricants  
used in the manufacturing process.  
If your millivolt appliance is equipped with an  
optional remote wall switch or remote control  
kit and the pilot is lit, the appliance main burner  
may be turned on and off with the wall switch  
or remote control.  
ON/OFF Switch  
Manifold Pressure Port  
3. Keep lower control compartment clean by  
vacuuming or brushing at least twice a year.  
More frequent cleaning may be required due to  
excessivelintfromcarpeting,beddingmaterials,  
etc. It is important that control compartments,  
burners and circulating air passageways of the  
appliancebekeptcleanandclearofobstruction  
of venting and combustion air.  
Inlet  
Pressure  
Port  
Electronic Appliances -  
To light electronic appliances refer to the  
detailed lighting instructions found in both  
English and French on pages 28 and 29 of  
these instructions respectively. Electronic  
appliance lighting instructions may also be  
foundonthepulloutlightinginstructionlabels  
attached to the gas control valve. Electronic  
appliances are fitted with an ON/OFF Rocker  
Switch for appliance ON/OFF control. Refer to  
Figure 1 for its location.  
Electronic  
Gas Control  
Valve  
4. Always turn off gas to the pilot (millivolt  
appliances) before cleaning. Before re-lighting,  
refer to the lighting instructions in this manual.  
Instructions are also found on a pull-out panel  
located on the floor of the appliance.  
Honeywell Electronic  
Gas Valve  
Figure 3  
Millivolt Appliances -  
5. Always keep the appliance area clear and  
free from combustible materials, gasoline and  
other flammable liquids.  
To light millivolt appliances refer to the detailed  
lightinginstructionsfoundonpage 26(English)  
and page 27 (French). Millivolt appliance  
lighting instructions may also be found on the  
pull out lighting instruction labels attached to  
the gas control valve.  
Once the pilot is lighted, the ON/OFF rocker  
switchwillcontroltheapplianceON/OFFopera-  
tion. To operate: Toggle the switch between its  
ON and OFF positions.  
6.Remember,Millivoltapplianceshaveacontin-  
uousburningpilotame.Exercisecautionwhen  
using products with combustible vapors.  
If your electronic appliance is equipped with an  
optionalremotewallswitchorremotecontrolkit  
theappliancemainburnermaybeturnedonand  
off with the wall switch or remote control.  
Millivolt appliances are fitted with an ON/OFF  
Rocker Switch for appliance ON/OFF control.  
Refer to Figure 1 for its location. Once the  
pilot is lighted, the ON/OFF rocker switch will  
control the appliance ON/OFF operation. To  
operate: Toggle the switch between its ON and  
OFF positions.  
9
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replacing Logs  
The viewing glass should be cleaned periodi-  
cally to remove any build-up caused from the  
following:  
MAINTENANCE  
If the logs become damaged by accident or  
improper handling and need replacement, use  
only the proper replacement logs from manu-  
facturer (see Pages 13 and 14 for ordering  
information).  
(See Maintenance Schedule, Page 25)  
IMPORTANT: Do not use abrasive clean-  
ers on glass. Never clean the glass when  
it is hot.  
Refertothemaintenancescheduleformaintenance  
tasks, procedures, periodicity and by whom they  
shouldbeperformed. Alwaysverifyproperopera-  
tion of the appliance after servicing.  
• During start-up, it is normal for condensa-  
tion to form on the inside of the glass (this  
condensation and fog will usually disappear  
in a few minutes). The moisture can cause  
lint,dustandotherairborneparticlestocling  
to the glass surface.  
• Initial curing of the high temperature paint  
and burning off of lubricants used in the  
manufacturing process may result in a film  
on the glass.  
Re-Install Embers and Logs  
WARNING  
Carefully follow placement instructions on  
Pages 12 through 14. All logs should fit  
onto corresponding pins and/or log stop-  
pers. This will ensure a proper flame and  
safe combustion.  
Turnoffgasandelectricalpower  
to the fireplace and allow it to  
coolbeforecleaningorservicing  
the appliance.  
Inspect Wiring  
Refer to wiring diagrams on Page 17.  
• A white coating may form on the glass as a  
result of impurities and minerals in the fuel.  
CAUTION: Wear gloves and safety  
glasses for protection while doing  
required maintenance.  
CAUTION: Labelallwirespriortodiscon-  
nection when servicing controls. Wiring  
errorscancauseimproperanddangerous  
operation. Verify proper operation after  
servicing.  
It is recommended that the glass be cleaned  
two or three times during each heating season,  
depending on the circumstances present. The  
following cleaning solutions are approved for  
use to clean glass:  
Verify proper operation after servicing.  
S'assurer que l'appareil fonctionne adé-  
quatement une fois l'entretien terminé.  
ATTENTION: Au moment de l'entretien  
des commandes, étiquetez tous les fils  
avant de les débrancher. Des erreurs de  
cáblage peuvent entraîner un fonction-  
nement inadéquat et dangereux.  
• Non-ammonia based household cleaner  
• 50%-50% mix of white vinegar and water  
• Gas fireplace/stove glass cleaner  
Always turn off gas to the pilot (millivolt  
appliances) before cleaning. Before re-  
lighting, refer to the lighting instructions  
inthismanual.Instructionsarealsofound  
on a pull-out panel located in the control  
compartment.  
Inspect Glass Gasket - Visually inspect the  
gasket on the backside of the glass enclosure  
panels. The gasket surface must be clean, free  
of irregularities and seated firmly.  
Inspect and clean all wire connections. Ensure  
that there is no melting or damage. Inspection  
should include:  
• Terminals at the Valve  
• OFF/ON Switch  
• (Optional Control Switch) Wall Thermostat,  
Remote Control or Remote Wall Switch Kit  
Inspect Venting System  
Clean Control Compartment  
The appliance and venting system should be  
thoroughly inspected before initial use and  
at least annually by a qualified service techni-  
cian (inspection should include ensuring that  
exhaust or intake passages are unobstructed  
and vent components are properly assembled  
and not damaged). Homeowner must contact  
a qualified service technician at once if any  
abnormal condition is observed.  
Keepcontrolcompartmentcleanbyvacuuming  
or brushing at least twice a year. More frequent  
cleaning may be required due to excessive lint  
from carpeting, bedding materials, etc. It is  
important that control compartments, burners  
andcirculatingairpassagewaysoftheappliance  
be kept clean.  
Inspect Burner Flame Appearance  
Ensure that the burner flame appearance  
resembles the flame shown in Figure 9 and  
asdescribedinFlameAppearanceandSooting  
on Page 15. The Homeowner must contact  
a qualified service technician at once if any  
abnormal condition is observed.  
Clean Logs And Burner  
If the venting system is disassembled for any  
reason, a qualified service technician should  
follow vent installation instructions for proper  
reassembly and proper sealing of the venting  
system components. However, more frequent  
periodic inspections and cleanings should be  
performed by the homeowner.  
Carefully remove the logs (use care when han-  
dlingtheberlogs,astheybecomequitefragile  
after curing). Vacuum out any foreign matter  
(lint, carbon, etc.) on the burner. Ensure the  
burner ports are “open.” Remove any carbon  
deposits from the under side of the logs using  
a vacuum cleaner, or a soft bristled brush (i.e.  
paint brush).  
Small Area Paint Touch-up  
Only use a factory supplied paint kit for touch-  
ups. Paint is available at your local authorized  
LennoxHearthProductsdealer. Neverattempt  
to paint a hot fireplace.  
Cleaning Glass  
(see Front Glass Enclosure Panel, Removal and  
Installation on Page 11).  
Do not attempt to repaint the appliance until  
the finish is completely cured (see Burn-In  
Period onPage7).Ifthesurfacelaterbecomes  
stainedormarred, itmaybelightlysandedand  
touched up with spray paint.  
Note: Improper positioning of logs can create  
carbon build-up and will alter the performance  
of the appliance.  
Note: Cleanglassafterrsttwoweeksofopera-  
tion(afterBurn-Inperiodisover)andthenonly  
when necessary and when the fireplace is cool.  
Wipesurfacewithaclean,dampened,softcloth.  
Follow with a dry, soft towel as desired. Take  
care not to scratch the glass surface.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Locate the two (2) latches at the top of the  
controlcompartmentanddisengagethemfrom  
thedoorframebottomvee-flange,pullingdown  
on their handles to open them.  
Front Glass Enclosure Panel, Removal  
and Installation  
WARNING  
Any safety screen or guard  
removed for servicing the appli-  
ance must be replaced prior to  
operating the appliance.  
WARNING  
Retrieve the glass door. Visually inspect the  
gasket on the backside of the frame. Gasket  
surface must be clean, free of irregularities  
and seated firmly.  
• Do not attempt to substitute  
the materials used on this door,  
or replace cracked or broken  
glass.  
Handlethisglasswithextreme  
care! Glass is susceptible to  
damage – Do not scratch or  
handle roughly while reinstall-  
ing the glass door frame.  
• The glass door(s) of this appli-  
ance must only be replaced as a  
completeunitasprovidedbythe  
manufacturer. Do not attempt  
to replace broken, cracked or  
chipped glass separately.  
Donotattempttotouchthefront  
enclosureglasswithyourhands  
while the fireplace is in use.  
AVERTISSEMENT  
Position the door in front of the firebox opening  
with the bottom of the door held away from the  
fireplace (Figure 4 ). Hook the top flange of the  
door frame over the top of the firebox frame.  
Tout écran ou protecteur retiré  
pour permettre l’entretien de  
l’appareil doit être remis en  
place avant de mettre l’appareil  
en marche.  
Let the bottom of the door frame swing gently  
intowardsthereplaceensuringthatthegasket  
seats evenly as the door frame draws shut.  
Fasten the two latches located underneath the  
firebox floor to the door's vee-flange. Close  
both the latches securely.  
Only doors certified with the appliance  
shall be used.  
Seules des portes certifiées pour cet  
appareil doivent être utilisées.  
Control Compartment Access Panel and Hinge  
Top Flange  
Glass Door Frame  
CAUTION: DO NOT abuse glass door by  
striking or slamming shut.  
Front Glass  
Enclosure Panel  
These are direct-vent appliances. They are  
designed to operate only when the front glass  
enclosure panels are installed. Generally the  
front glass enclosure panel should not be re-  
moved except to gain access to the components  
within the firebox.  
WARNING  
Do not operate appliance with  
theglassfrontremoved,cracked  
or broken.  
Removing Glass Enclosure Panels  
(see Figure 4 )  
Remove the top louver assembly or radiant  
panel.  
Bottom Vee-flange  
Glass Door Frame  
AVERTISSEMENT  
Firebox Floor  
Glass Door Latch  
Ne pas utiliser l'appareil si le  
panneau frontal en verre n'est  
pas en place, est craqué ou  
brisé.  
To access the glass door securing latches,  
first open the lower control compartment door  
(Figure4)bypushinginsimultaneouslytheleft  
and right top corners of the door. (The door  
is hinged at the bottom.) Remove the bottom  
compartment door by sliding the hinge pin,  
located at the door’s left side, to the right until  
it disengages from the left corner post hole.  
Pull the door diagonally to the left, away from  
the fireplace.  
Figure 4  
EDVST SHOWN  
INSTALL VERMICULITE, GLOWING EM-  
BERS AND LOGS  
NOTE: Turn off all electricity to the appliance  
beforeyouinstallvermiculite,embersandlogs.  
DO NOT attempt to install the logs until the ap-  
plianceinstallationhasbeencompleted,thegas  
lineconnectedandtestedforleaksandtheinitial  
burner operation has been checked out.  
11  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION STEPS:  
REFERENCE  
Firebox Accessories / Parts  
READ WARNINGS ON THIS PAGE BEFORE PROCEEDING. FOLLOW THE  
LOG PLACEMENT INSTRUCTIONS EXACTLY  
Cat. No.  
88L53  
Model No.  
Description  
FGE  
Bag of Glowing Embers  
1. Remove the front glass enclosure panel (see Glass Enclosure Panel  
Removal and Installation Instructions, Page 11 ).  
80L42  
FDVS  
Bag of Decorative Volcanic Stone  
2. Remove the following from firebox; log set, bag of embers and bag  
of vermiculite. Handle logs carefully to prevent breakage.  
3. Ensure the Grate is properly installed in the firebox with the 4 legs  
of the grate fitting into the 4 dimples on the firebox floor.  
4. Placement of Glowing Embers -  
WARNING  
• DO NOT attempt to install the logs until the appli-  
ance installation has been completed, the gas line  
connected and tested for leaks and the initial burner  
operation has been checked out.  
Thesizeandpositionofthelogsetwasengineered  
to give the appliance a safe, reliable and attractive  
flame pattern. Any attempt to use a different log  
set in the fireplace will void the warranty and will  
result in incomplete combustion, sooting, and poor  
flame quality.  
Logs get very hot and will remain hot up to one  
houraftergassupplyisturnedoff. Handleonlywhen  
logs arecool. Turnoffallelectricitytotheappliance  
beforeyouinstallgrate,volcanicstone,vermiculite,  
embers and logs.  
Separatethe Embers(rockwool)intopiecesabout thesizeofaquarter  
(see Figure 5). Keep the pieces fluffed up, not matted. Distribute  
these pieces over the surface of the burner, as shown in Figure 6.  
Do not use more than is necessary. Ensure that the main burner ports  
remain uncovered by the ember material.  
5. Place Lava Rock - Spread lava rock evenly over firebox floor.  
6. Install Vermiculite - Place some vermiculite on the firebox floor  
around the grate (the entire bag of vermiculite will NOT be used). See  
Figure 6. DO NOT PLACE ANY VERMICULITE ON THE BURNER.  
Note: This appliance is provided with enough Glowing Embers for several  
applications, do not use all that is in a new bag at one time. For best  
glowingeffect,replacetheembermaterialannually.ReplacementGlowing  
Embers are available (order Catalog Number 88L53).  
This appliance is not designed to burn wood. Any  
attempt to do so could cause irreparable damage to  
the appliance and prove hazardous to your safety.  
If logs are not installed according to the log  
installation instructions, flame impingement and  
impropercombustioncouldoccurandresultinsoot  
and/or excessive production of carbon monoxide  
(CO), a colorless, odorless, toxic gas.  
Figure 5  
Glowing Embers  
Figure 6  
12  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDVPF, EDVST, EDVCL AND EDVCR LOG PLACEMENT  
Log  
Part  
Number  
6
4
2
Number Description  
1
2
3
4
5
6
Log, Corner  
55M18  
55M19  
55M20  
55M21  
55M22  
55M23  
Log, Rear/Left  
Log, Front/Left  
Log, Rear/Right  
Log, Front/Center  
Log, Center/Top  
Catalog Number for the entire log set: 55M04  
1
3
5
Log (3) Lays Over Logs  
3
1 And 2  
STEP 3  
1
STEP 1  
Place Bottom Hole Of Log (3) On Pin In Log (2). Position  
Grooves At The Bottom Of Log (3) Over The Grate.  
Position Groove At The  
Bottom Of Log (1) Over  
The Burner Log Support  
Bracket  
Position The Groove At The  
Bottom Of Log (1) Over The  
Grate And Slide It Forward  
Against The Grate Here  
Position And Slide Log (4)  
1
Against The Back Of The Grate  
STEP 4  
Position Log (2) Over The Grate  
Bar And Slide It Against The Back  
Of The Grate Here  
2
STEP 2  
Place Log (4) Over  
4
The Flat Spot On  
Position Groove At The Bottom Of Log (2)  
Over The Grate Here And Slide It Against  
The Back Of The Grate  
Log (1) Here  
Figure 7  
13  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EDVPF, EDVST, EDVCL AND EDVCR LOG PLACEMENT (CONTINUED)  
Log  
Part  
Number  
6
4
Number Description  
2
1
2
3
4
5
6
Log, Corner  
55M18  
55M19  
55M20  
55M21  
55M22  
55M23  
Log, Rear/Left  
Log, Front/Left  
Log, Rear/Right  
Log, Front/Center  
Log, Center/Top  
Catalog Number for the entire log set: 55M04  
3
1
5
Position The Round End Of Log (6)  
Against The Notch Of Log (4) Here.  
Two Charred Spots Face The Front  
Position Small End Of Log (6)  
On The Notch Of Log (3) Here  
6
STEP 5  
3
4
Rest Log (5) Against  
The Grate Here  
Grate  
Assembly  
Position The Groove In The Back  
Of Log (3) Against The Grate  
Log (5) Sits In Front  
Of The Grate  
5
Figure 8  
14  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Air Shutter Adjustment Guidelines  
The following chart is provided to aid you in  
achieving the correct air shutter adjustment  
for your installation.  
BURNER ADjUSTMENTS  
(QUALIFIED TECHNICIANS ONLY)  
• If there is smoke or soot present, first  
check the log set positioning to ensure that  
the flames are not impinging on any of the  
logs. If the log set is properly positioned  
and a sooting condition still exists, then the  
air shutter opening should be increased.  
• Themoreoffsetsintheventsystem,thelarger  
the air shutter opening will need to be.  
• An appliance operated with the air shutter  
opened too far, may have flames that appear  
blue and transparent. These weak, blue and  
transparent flames are termed anemic.  
• Propane models may exhibit flames which  
candle or appear stringy. If this is present  
and persists, adjust the air shutter to a more  
closed position, then operate the appliance  
for a few more minutes to ensure that the  
flame normalizes and the flames do not  
appear sooty.  
Flame Appearance and Sooting  
Air Shutter Adjustment Guidelines:  
Proper flame appearance is a flame which is  
blueatthebaseandbecomesyellowish-orange  
in the body of the flame.  
Amount of  
Primary Air  
Flame  
Color  
Air Shutter  
Adjustment  
If air shutter is  
closed too far  
Flame will Air shutter  
be orange gap should be  
increased  
When the appliance is first lit, the entire flame  
may be blue and will gradually turn yellowish-  
orangeduringtherst15minutesofoperation.  
If the flame remains blue, or if the flame is  
orange with evidence of sooting (black tip), the  
air shutter opening may need to be adjusted.  
If air shutter is  
open too far  
Flame will Air shutter  
be blue gap should be  
decreased  
If the air shutter opening is closed too far,  
sooting may develop. Sooting is indicated by  
black puffs developing at the tips of very long  
orangeames. Sootingresultsinblackdeposits  
forming on the logs, appliance inside surfaces  
and on exterior surfaces adjacent to the vent  
termination.  
Sooting is caused by incomplete combustion  
in the flames and lack of combustion air enter-  
ing the air shutter opening. To achieve a warm  
yellowish-orange flame with an orange body  
that does not soot, the shutter opening must be  
adjusted between these two extremes.  
Glowing Embers (Rockwool)  
Figure 9 - Burner Flame Appearance  
15  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BURNER FLAME ADjUSTMENTS  
Air Shutter  
Adjusting  
Rod  
Hood Igniter Rod  
MILLIVOLT  
Thermocouple  
WARNINGS  
Orifice  
Airshutteradjustmentshould  
only be performed by a quali-  
fiedprofessionalservicetech-  
nician.  
Ensure front glass panel are  
in place and sealed during  
adjustment.  
3/8" Min  
(9 mm)  
Pilot  
Increase Shutter  
Nozzels  
Opening In This  
Direction  
Thermopile  
Decrease Shutter  
Opening In This  
Direction  
Figure 11  
Note - Burners are omitted in this view for clarity.  
CAUTIONS  
Electronic Appliance Checkout  
Soot will be produced if the  
airshutterisclosedtoomuch.  
Any damage due to sooting,  
resulting from improperly  
setting the air shutter, is not  
covered under the warranty.  
The air shutter door and  
nearby appliance surfaces  
are hot. Exercise caution to  
avoid injury while adjusting  
flame appearance.  
MAIN BURNER  
FACTORY SHUTTER SETTING  
Natural Gas Propane Gas  
To light the burner, turn ‘ON’ the unit mounted  
On/Offswitchortheoptionalremotewallswitch.  
Ensure the igniter lights the pilot. The pilot  
flame should engulf the flame rod as shown  
in Figure 12.  
Models  
inches  
(mm)  
inches  
(mm)  
EDVST  
EDVPF  
EDVCR  
EDVCL  
1/4"  
(6.35)  
5/8"  
(15.88)  
ELECTRONIC  
3/8 To 1/2 Inch  
(9 mm to 13 mm)  
Proper Flame  
Adjustment  
Adjustment Rod Positions (when viewed from above)  
Figure 10  
Pilot  
Nozzle  
Ground  
1. Refer to Figure 9 for proper flame ap-  
pearance. To adjust the flame, rotate the  
adjustment rod toward the back or toward  
the front of the fireplace (rod located in  
the lower control area). Position the air  
shutter to the factory setting as shown in  
the table in Figure 10.  
2. Light appliance (follow lighting procedure  
on lighting label in control compartment  
or see the Care and Operation Manual).  
3. Allow the burner to operate for at least 15  
minutes while observing the flame con-  
tinuously to ensure that the proper flame  
appearance has been achieved. If the  
following conditions are present, adjust  
accordingly.  
Electrode  
Millivolt Appliance Checkout  
Flame Rod  
The pilot flame should be steady, not lifting  
or floating. Flame should be blue in color with  
traces of orange at the outer edge.  
Hot Surface  
Igniter  
Figure 12  
The top 3/8" (10 mm) at the pilot generator  
(thermopile) and the top 1/8" minimum (tip)  
of the quick drop out thermocouple should be  
engulfed in the pilot flame.  
Theameshouldproject1"(25mm)beyondthe  
hoodatallthreeports(seeFigure11). Replace  
logs if removed for pilot inspection.  
To light the burner; turn “ON” the remote wall  
switch and rotate the gas valve control knob  
counterclockwise to the “ON” position (“ON”  
will be at the top side of the valve).  
If flame appears weak or sooty, adjust  
the air shutter, incrementally, to a  
more open position until the proper  
flame appearance is achieved.  
If flame remains blue, adjust the air  
shutter, incrementally, to a more  
closed position until the proper flame  
appearance is achieved.  
4. Leave the control knob (off/pilot/on)  
in the ON position and the burner OFF/  
ON switch OFF (and remote switches, if  
applicable).  
5. When satisfied that the burner flame ap-  
pearance is normal, re-install the lower  
control compartment door then proceed  
to finish the installation.  
16  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WIRING DIAGRAMS  
ATTENTION: AU MOMENT DE L'ENTRETIEN DES COMMANDES, ÉTIQUETEZ  
TOUS LES FILS AVANT DE LES DÉBRANCHER. DES ERREURS DE CÁBLAGE  
PEU-VENT ENTRAÎNER UN FONCTIONNEMENT INADÉQUAT ET DANGEREUX.  
Wiringdiagramsareprovidedhereforreference  
purposesonly. Thisinformationisalsoprovided  
onschematicsattacheddirectlytotheappliance  
on a pullout panel located within the control  
compartment.  
Electronic Wiring Diagram (Honeywell)  
Showing the Blower Wiring for the Optional  
FBK-250 Kits  
Electronic Wiring Diagram (Honeywell)  
Showing the Blower Wiring for the Optional  
FBK-100 and FBK-200 Kits  
1. If any of the original wire as supplied must be replaced,  
1. it must be replaced with Type AWM 105°C – 18 GA. wire.  
2. 120V, 60Hz – Less than 3 amps.  
1. If any of the original wire as supplied must be replaced,  
1. it must be replaced with Type AWM 105°C – 18 GA. wire.  
2. 120V, 60Hz – Less than 3 amps.  
CAUTION:LABELALLWIRESPRIORTO  
DISCONNECTION WHEN SERVICING  
CONTROLS. WIRING ERRORS CAN  
CAUSEIMPROPERANDDANGEROUS  
APPLIANCE OPERATION.  
**Leave the ON/OFF switch, which is integral  
**ON/OFF Switch (Integral  
*Leave the ON/OFF switch, which is integral  
with the gas valve, in the ON position.  
*ON/OFF Switch (Integral  
with Gas Valve)  
with the gas valve, in the ON position.  
with Gas Valve)  
Gas Valve  
PILOT  
Gas Valve  
PILOT  
ASSEMBLY  
ASSEMBLY  
Ground - Green  
Neutral - White  
BK  
120 VAC - Black  
BK  
Optional  
FBK-250  
Module  
R
R
Green  
BL  
White  
Black  
Ground - Green  
Neutral - White  
120 VAC - Black  
BL  
Green  
White  
Black  
Millivolt Wiring Diagram  
If any of the original wire as supplied must be replaced,  
it must be replaced with Type AWM 105° C – 18 GA. wire.  
OPT  
BLOWER  
junction Box  
OPT  
BLOWER  
Tab Intact  
junction Box  
Ta b  
Broken  
Tab Intact  
Ta b  
Broken  
Red  
Optional  
Accessory  
Switch  
Green  
Ground  
Screw  
Hot  
Neutral  
Red  
Optional  
Accessory  
Switch  
Side of  
Side of  
Green  
Ground  
Screw  
Receptacle  
Receptacle  
Hot  
Neutral  
Side of  
Receptacle  
Side of  
W
Receptacle  
Transf.  
120 V.  
B
W
B
G
Transf.  
120 V.  
G
Thermopile  
24 V  
BL  
24 V  
BL  
R
Field Wired  
Factory Wired  
W
R
BK  
WH  
BK  
APPLIANCE-MOUNTED ON/OFF SWITCH  
*OR OPTIONAL WALL-MOUNTED ON/OFF SWITCH  
OR OPTIONAL THERMOSTAT  
OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH  
OR OPTIONAL WALL SWITCH  
OR OPTIONAL REMOTE CONTROL RECEIVER  
OR OPTIONAL THERMOSTAT  
OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH  
OR OPTIONAL WALL SWITCH OR OPTIONAL THERMOSTAT  
OR OPTIONAL REMOTE RECEIVER  
OR OPTIONAL REMOTE RECEIVER  
*Turn the appliance-mounted ON/OFF burner control switch  
to the OFF position if an optional  
*Blower speed control switch is provided in FBK200 blower kit.  
control switch is installed.  
Factory Wired  
Field Wired  
Factory Wired  
Field Wired  
Schematic Representation Only  
Schematic Representation Only  
Schematic Representation Only  
WARRANTY  
LENNOX HEARTH PRODUCTS  
1508 Elm Hill Pike, Suite 108  
Nashville, TN 37210  
1-800-9-LENNOX  
Parts will be shipped at prevailing prices at  
time of order.  
Your gas appliance is covered by a twenty year  
limitedwarranty. Youwillndacopyofthewar-  
ranty accompanying this manual. Please read  
the warranty to be familiar with its coverage.  
When ordering repair parts, always give the  
following information:  
1. The model number of the appliance.  
2. The serial number of the appliance.  
3. The part number.  
4. The description of the part.  
5. The quantity required.  
6. The installation date of the appliance.  
PRODUCT REFERENCE INFORMATION  
Retain this manual. File it with your other docu-  
ments for future reference.  
We recommend that you record the following  
important information about your fireplace.  
Please call Lennox Hearth Products for the  
phone number of your nearest Lennox Hearth  
Productsdealerwhowillansweryourquestions  
or address your concerns.  
REPLACEMENT PARTS  
If you encounter any problems or have any  
questions concerning the installation or ap-  
plication of this system, please contact your  
dealer or distributor.  
A complete parts list is found at the end of  
this manual. Use only parts supplied from the  
manufacturer.  
Withpropercareandmaintenance, yourappli-  
ance will provide many years of enjoyment. If  
you should experience any problem, first refer  
to the troubleshooting guide in this manual. If  
problem persists, contact your Lennox Hearth  
Products dealer or distributor.  
Your Fireplace's Model Number___________________________________________  
Your Fireplace's Serial Number ___________________________________________  
The Date On Which Your Fireplace Was Installed______________________________  
The Type of Gas Your Fireplace Uses _______________________________________  
Your Dealer's Name ___________________________________________________  
Normally,allpartsshouldbeorderedthroughyour  
Lennox Hearth Products distributor or dealer.  
17  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORY COMPONENTS  
Product Reference Information  
Cat. No.  
Model  
Ship.  
Weight  
Ship.  
Volumn  
H0721  
H0722  
H0723  
H0724  
H0725  
H0726  
H0727  
H0728  
H0729  
H0730  
H0731  
H0732  
EDVSTNM  
EDVSTNE  
EDVSTPM  
EDVPFNM  
EDVPFNE  
EDVPFPM  
EDVCLNM  
EDVCLNE  
EDVCRNM  
EDVCRNE  
EDVCLPM  
EDVCRPM  
282 lbs.  
282 lbs.  
282 lbs.  
270 lbs.  
270 lbs.  
270 lbs.  
272 lbs.  
272 lbs.  
272 lbs.  
272 lbs.  
272 lbs.  
272 lbs.  
(36.2 cu.ft.)  
(36.2 cu.ft.)  
(36.2 cu.ft.)  
(36.2 cu.ft.)  
(36.2 cu.ft.)  
(36.2 cu.ft.)  
(36.2 cu.ft.)  
(36.2 cu.ft.)  
(36.2 cu.ft.)  
(36.2 cu.ft.)  
(36.2 cu.ft.)  
(36.2 cu.ft.)  
Flame Modulating Remote Control  
– Natural Gas  
Flame Modulating Remote Control  
– LP/Propane Gas  
H0301  
H0302  
RCL-MN  
RCL-ML  
Remote Control Kit, Deluxe  
Cat. No.  
H0251  
Model No.  
RCL-STAT  
Description  
Remote Control System  
(Deluxe)  
Flame Modulating Remote Control  
Deluxe Remote Control System  
FlameModulatingRemoteControlsweredevel-  
opedtoprovideasafe,reliableanduser-friendly  
remotecontrolsystemforappliancesequipped  
with a Millivolt Gas Valve. A detailed set of  
instructions are included with each remote.  
The Model RCL-T (Deluxe) Remote Control System  
has all of the features of the standard system along  
withanaddedeasytoreadLCDscreenwhichpresents  
access to many enhancements, including; battery  
power level indicator, timer, mode of operation,  
thermostatic display including room temperature in  
either metric of English units, flame indicator and  
clock. Fully programmable, the Model RCL-T allows  
for virtual command over nearly all operational and  
temperature variables, using the hand held remote  
control transmitter.  
The Model RCL-T (Deluxe) remote control system  
is installed in the same manner as the standard  
system, may be operated with electronic and mil-  
livolt systems with either natural gas or propane gas.  
The RCL-T comes complete with detailed operating  
instructions.  
Remote Control Kit, Standard  
Cat. No.  
H0249  
Model No.  
RCL  
Description  
Remote Control System  
(Standard)  
Forced Air Blower Kits  
Standard Remote Control System  
Cat.  
No.  
Model No.  
FBK-100  
FBK-200  
FBK-250  
Description  
The Model RCL (Standard) Remote Control System,  
features a simplistic OFF/ON control function for the  
fireplace. Thismodelincludesahand-heldtransmitter,  
a remote receiver with wall-mount cover plate and  
all hardware required to install the unit. The remote  
receiver can be wall or hearth mounted.  
80L84  
80L85  
80L86  
Blower, Standard  
(single speed)  
Blower, Variable Speed  
(w/wall-mounted switch)  
The transmitter has ON and OFF functions that are  
activated by pressing either button on the face of  
the transmitter. When a button on the transmitter  
is pressed, a signal light illuminates briefly to verify  
that a signal has been sent.  
Blower, Variable Speed (w/  
unit-mounted switch)  
94L89  
94L90  
FBK-100-36  
FBK-200-36  
Blower, Standard, 36 Pack  
Forced Air Kit  
TheFBK-100blowerprovidesconstantvelocityforced  
air circulation. The FBK-200 assembly with variable  
speed,wall-mountableswitchprovidesvariablespeed  
forced air circulation. The FBK-250 assembly with  
variable speed unit-mountable switch, also provides  
variable speed forced air circulation.  
Blower Kit - Variable Speed  
with Wall Switch 36 Pack  
The Model RCL is designed to operate with all mil-  
livolt ignition systems, as well as electronic ignition  
systems. It may be installed with use for either  
natural gas or propane gas appliances. The RCL  
offers ease of installation and allows you to execute  
on-off commands to the fireplace effortlessly with  
one simple motion.  
H0543  
FBK-250-36  
Blower Kit - Variable Speed  
with Thermo Snap Switch  
36 Pack  
TheModelRCLcomescompletewithdetailedoperat-  
ing instructions.  
18  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORY COMPONENTS CONTINUED  
Door Frame Kits  
Adecorativedoorframekitisavailableforuse  
with these appliances. The DTK is designed  
to attach directly to the front face of the appli-  
ance at its extreme edges. The DTK provides  
a picture frame finish for the appliance. The  
door frame kit can be retrofitted onto previ-  
ously installed appliances.  
I
Touch-Up Paint Kits  
Cat. No.  
90L73  
Model No.  
TPK-B  
Description  
Touch-Up Paint (Black)  
Touch-Up Paint Kit  
Repair of minor scratches and discoloration of the  
appliance charcoal painted surfaces may be accom-  
plished with the touch-up paint kit.  
Door Frame Kits  
CATALOG NO. / MODEL NO. AND NUMBER OF SETS  
Polished Brass Finish  
Brushed Stainless Finish  
Unit  
Model  
No.  
for 24 in. wide for 40 in. wide for 24 in. wide for 40 in. wide  
Glass Door  
Glass Door  
Glass Door  
Glass Door  
88L43  
DTK24PB-2  
88L45  
DTK40PB-2  
90L69  
DTK24BS  
90L71  
DTK40BS  
EDVST  
EDVPF  
EDVCR  
EDVCL  
-
1
2
2
-
1
2
2
Decorative Firebox Accessories  
1
1
1
1
Cat. No.  
88L53  
Model No.  
FGE  
Description  
Bag of Glowing Embers  
Bag of Decorative  
Volcanic Stone  
80L42  
FDVS  
Arch Door Kits  
Bag of Glowing Embers  
Two types of arch door kits are available for  
the Multi-Open Series. Both types of kits are  
easy to install and do not require hardware to  
attach them to the standard door frame. These  
kits can be retrofitted to previously installed  
Multi-Open Series appliances. The decorative  
arch kits can not be used in conjunction with  
the screen panel kit.  
Bag of Volcanic Stone  
Replacement ember materials or volcanic stone are  
available for use with these appliances. Order kits as  
part of the periodic maintenance of the appliance.  
Arch Door Kits - CATALOG NO. / MODEL NO. AND QUANTITY  
Polished Brass Finish Brushed Stainless Finish  
for 24 in. wide for 40 in. wide for 24 in. wide for 40 in. wide  
Unit  
Model  
No.  
Glass Door  
Glass Door  
Glass Door  
Glass Door  
81L37  
ADK24CPB  
81L35  
ADK40CPB  
98L71  
ADK24CBS  
98L69  
ADK40CBS  
EDVST  
EDVPF  
EDVCR  
EDVCL  
-
1
2
2
-
1
2
2
1
1
1
1
19  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORY COMPONENTS CONTINUED  
Black Finish Louvers Kits  
Decorative louvers are available for use with all  
Multi-Open Series appliances. These louvers are  
designed to replace the standard radiant panels  
that are provided with the appliance. These kits  
include a black finish top 3-piece assembly and  
a bottom 3-piece assembly. These kits can be  
retrofitted to previously installed appliances.  
Wall Thermostat, Millivolt  
Cat. No.  
H4635  
Model No.  
DWTK  
Description  
Wall Thermostat Kit,  
White  
Black Finish Louver Assembly Kits  
(3-piece Top and 3-piece Bottom Assembly)  
CATALOG NO. / MODEL NO. AND NUMBER OF SETS  
Digital Wall Thermostat  
The wall thermostat kit provides temperature control  
for optimum comfort.  
Black Finish  
Unit  
Model  
No.  
for 24 in. wide  
Glass Door  
for 40 in. wide Glass  
Door  
88L23  
LVR24C-2  
88L25  
LVR40C-2  
EDVST  
EDVPF  
EDVCR  
EDVCL  
-
1
2
2
1
1
White Wall Switch Kit  
Polished Brass and Brushed Stainless  
Hood Kits  
Cat. No.  
85L87  
Model No.  
FWSK  
Description  
OFF/ON Wall Switch Kit  
Attractive hoods are available in two styles to be  
used on the Multi-Open Series appliances. These  
hoodsaredesignedtobettedtotheglassviewing  
sides of the appliance. In addition to providing an  
aestheticallypleasingappearancetoyourappliance  
installation, thehoodreducesheateffectstodeco-  
rative mantles and finish materials located above  
the fireplace opening. The hood kit replaces the  
standard hood that comes with these appliances  
and snaps into place. These kits can be retrofitted  
to previously installed appliances.  
OFF/ON Wall Switch Kit  
The OFF/ON wall switch kit may be used to control  
the operation of the fireplace burner. Install the OFF/  
ON wall switch in a convenient location near the  
fireplace.  
Hood Kits  
CATALOG NO. / MODEL NO. AND NUMBER OF SETS  
Polished Brass Finish  
Brushed Stainless Finish  
Unit  
Model  
No.  
for 24 in. wide for 40 in. wide for 24 in. wide  
for 40 in. wide  
Glass Door  
Glass Door  
Glass Door  
Glass Door  
96K28  
EB24PB  
96K68  
EB40PB  
88L47  
EB24BS  
88L50  
EB40BS  
EDVST  
EDVPF  
EDVCR  
EDVCL  
-
1
2
2
-
1
2
2
1
1
1
1
20  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORY COMPONENTS CONTINUED  
2-Piece Polished Brass and Brushed  
Stainless Louvers Kits  
Decorative louvers are available for use with all  
Multi-OpenSeriesappliances.Theselouversare  
designed to replace either the middle charcoal  
louver of each set or the charcoal louver in each  
set closest to the glass door. These kits include  
two narrow louvers. They provide a touch of  
elegance to any Multi-Open Series appliance.  
These kits can be retrofitted to previously  
installed appliances.  
Screen Panel Kit  
24 inch Wide Glass Door  
40 inch Wide Glass Door  
98K74  
96K32  
HG24  
HG40  
Louver Kits (2-piece)  
CATALOG NO. / MODEL NO. AND NUMBER OF SETS  
Screen Panel Kit  
Anoptionalscreenpanelcanbeinstalledonthe  
Multi-Open Series doors. These screen panels  
are easy to install. These kits can be retrofitted  
to previously installed appliances. The screen  
panel kits can not be used in conjunction with  
either of the arch door kits or door frame kits.  
Polished Brass Finish  
Brushed Stainless Finish  
Unit  
Model  
No.  
for 24 in. wide for 40 in. wide for 24 in. wide  
for 40 in. wide  
Glass Door  
96L04  
Glass Door  
96L06  
Glass Door  
96L08  
Glass Door  
96L10  
2LVR24PB  
2LVR40PB  
LVR24BS  
LVR40BS  
EDVST  
EDVPF  
EDVCR  
EDVCL  
-
1
2
2
-
1
2
2
1
1
1
1
Polished Brass and Brushed Stainless  
Louvers Kits  
Decorative louvers are available for use with all  
Multi-OpenSeriesappliances.Theselouversare  
designedtoreplacethestandardradiantpanels  
that are provided with theappliance. These kits  
include a top 3-piece assembly and a bottom  
3-piece assembly. They provide a touch of  
elegance to any Multi-Open Series appliance.  
These kits can be retrofitted to previously  
installed appliances.  
Louver Assembly Kits (3-piece Top and 3-piece Bottom Assembly)  
CATALOG NO. / MODEL NO. AND NUMBER OF SETS  
Polished Brass Finish  
Brushed Stainless Finish  
Unit  
Model  
No.  
for 24 in. wide for 40 in. wide for 24 in. wide for 40 in. wide  
Glass Door  
Glass Door  
Glass Door  
Glass Door  
88L27  
LVR24PB-2  
88L29  
LVR40PB-2  
88L31  
LVR24BS  
88L33  
LVR40BS  
EDVST  
EDVPF  
EDVCR  
EDVCL  
-
1
2
2
-
1
2
2
1
1
1
1
21  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORY COMPONENTS CONTINUED  
Bricaded Panel Liner Kits  
Catalog No.  
Model No.  
Model No.  
H0778  
EBLK-PF  
EDVPF  
H0779  
EBLK-ST  
H0780  
EBLK-CL  
H0781  
EBLK-CR  
EDVST  
EDVCL  
H0779  
(Top Vent)  
EDVCR  
The brickaded liner kits include  
ceramic panels as shown here.  
Thepanelshavebrick-likefeatures  
in relief.  
H0780 & H0781  
(Top Vent)  
H0778  
(Top Vent)  
H0779  
(Rear Vent)  
H0778  
(Rear Vent)  
H0780 & H0781  
(Rear Vent)  
22  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORY COMPONENTS CONTINUED  
Style View Doors -  
Style View Doors come in 4 beautiful styles. They are easy to install and will not require hardware to attach them to the  
standard glass door frame. The door includes heavy duty magnet door latches and functional twin-pane doors.  
Arch Design  
Square Design  
Arch Pane Design  
Square Pane Design  
ARCH DESIGN KITS  
SQUARE DESIGN KITS  
Description  
Cat. No.  
H0862  
H0863  
H0864  
H0865  
Model  
AD40C  
Description  
Model Series  
Cat. No.  
H0950  
H0951  
H0952  
H0953  
Model  
SD40C  
Model Series  
40” Arch Doors, Black  
40” Sq. Doors, Black  
EDVST  
EDVPF  
EDVCR  
EDVCL  
EDVST  
EDVPF  
EDVCR  
EDVCL  
AD40TI  
AD40SP  
AD40AB  
40” Arch Doors, Textured Iron  
40” Arch Doors, Satin Pewter  
40” Arch Doors, Antique Brass  
ARCH PANE DESIGN KITS  
40” Arch Pane Doors, Black  
40” Arch Pane Doors, Textured Iron  
40” Arch Pane Doors, Satin Pewter  
40” Arch Pane Doors, Antique Brass  
SD40TI  
SD40SP  
SD40AB  
40” Sq. Doors, Textured Iron  
40” Sq. Doors, Satin Pewter  
40” Sq. Doors, Antique Brass  
SQUARE PANE DESIGN KITS  
40” Sq. Pane Doors, Black  
40” Sq. Pane Doors, Textured Iron  
40” Sq. Pane Doors, Satin Pewter  
40” Sq. Pane Doors, Antique Brass  
H0966  
H0967  
H0968  
H0969  
SPD40C  
SPD40TI  
SPD40SP  
SPD40AB  
H0934  
H0935  
H0936  
H0937  
APD40C  
APD40TI  
APD40SP  
APD40AB  
EDVST  
EDVPF  
EDVCR  
EDVCL  
EDVST  
EDVPF  
EDVCR  
EDVCL  
23  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORY COMPONENTS CONTINUED  
Style View Doors Continued -  
Style View Doors also come in a Tall Arch Pane Design. Two distinctive grille kits, the “Crescents” and “Sunrise” design, are  
also offered seperately. They are easy to install and will not require hardware to attach them to the standard glass door frame.  
The door includes heavy duty magnet door latches and functional twin-pane doors.  
TALL ARCH PANE DOORS  
Cat. No.  
H3529  
Model  
TAPD40C  
TAPD40SP  
Description  
Model Series  
EDVST  
40” Arch Pane Doors, Black  
40” Arch Pane Doors, Satin Pewter  
Tall Arch Pane Door  
H3531  
Sunrise Grille Kits  
Crescents Grille Kits  
“Crescents” Grille Kits  
“Sunrise” Grille Kits  
Cat. No.  
Model  
Description  
Model Series  
EDVST  
Cat. No.  
Model  
Description  
Model Series  
EDVST  
H3549 CUGK40C  
40” Crescents Upper Grille Kit, Black  
H3573 SUGK40C  
40” Sunrise Upper Grille Kit, Black  
CUGK40SP 40” Crescents Upper Grille Kit, Satin Pewter  
H3551  
SUGK40SP 40” Sunrise Upper Grille Kit, Satin Pewter  
H3575  
H3553 CLGK40C  
40” Crescents Lower Grille Kit, Black  
H3577 SLGK40C  
40” Sunrise Lower Grille Kit, Black  
H3555  
CLGK40SP 40” Crescents Lower Grille Kit, Satin Pewter  
H3579  
SLGK40SP 40” Sunrise Lower Grille Kit, Satin Pewter  
Arch Screen Panel Kit  
40" Decorative Arch Screen Panel Kit - Textured Iron  
Model No.  
DASPK40TI  
Catalog No.  
H3594  
This screen panel kit can be installed on the glass enclosure panel to prevent direct contact with  
the hot glass surface. The panel kit adds a new design choice with a handsome textured iron  
finish. The screen panel kit cannot be used in conjunction with either of the arch door kits or  
door frame kits.  
24  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE SCHEDULE  
Annually (Before the onset of the Burning Season)  
MAINTENANCE TASK  
ACCOMPLISHING PERSON  
PROCEDURE  
Inspecting/Cleaning Burner, Logs  
and Controls  
Qualified Service Technician  
Inspect valve and ensure it is properly operating. Check piping  
for leaks. Vacuum the control compartment, fireplace logs and  
burner area.  
Check Flame Patterns and Flame Qualified Service Technician  
Height  
Refer to Figure 9 on Page 15 and verify the flame pattern and  
heightdisplayedbytheapplianceconformstothepicture. Flames  
must not impinge on the logs. Ensure flames are steady (not  
lifting or floating).  
Inspecting/Cleaning Pilot and Burner  
Checking Vent System  
Qualified Service Technician  
Qualified Service Technician  
Refer to Figures 11 and 12 on Page 16. Remove any surface  
build-up on pilot and burner assembly. Wipe the pilot nozzles,  
igniter/flame rod and hood. Ensure the pilot flame engulfs the  
flame sensor as shown.  
Inspect the vent system at the top and at the base (within the  
firebox) for signs of blockage or obstruction. Look for any signs  
of dislocation or deterioration of the vent components. Note:  
Excessive condensation can cause corrosion of caps, pipe &  
fittings (excessive condensation can be caused by long lateral  
runs, too many elbows and/or exterior portions of the system  
being exposed to cold weather). Also inspect wall straps or  
plumbers's tape to ensure it is secure and in place.  
Appliance Checkout  
Qualified Service Technician  
Perform the appropriate appliance checkout procedure detailed  
in this manual.  
Replacing Rockwool Ember Materials Homeowner/Qualified Service  
Technician  
Remove old ember materials (rockwool) and vacuum the  
rockwool placement area. Place new embers as described in  
this document.  
Periodically (After the Burning Season)  
MAINTENANCE TASK  
ACCOMPLISHING PERSON  
PROCEDURE  
Cleaning Firebox Interior  
Homeowner  
Carefullyremovelogs,rockwool,volcanicstoneandvermiculite.  
Vacuum out interior of the firebox. Clean firebox walls and log  
grate. Replace logs, Rockwool and vermiculite as detailed in  
this manual.  
Check Flame Patterns and Flame Homeowner  
Height  
Refer to Figure 9 on Page 15 and verify the flame pattern and  
heightdisplayedbytheapplianceconformstothepicture.Flames  
must not impinge on the logs.  
Checking Vent System  
Homeowner  
Inspect the vent system at the top and at the base (within the  
firebox) for signs of blockage or obstruction. Look for any signs  
of dislocation of the vent components.  
Cleaning Front Glass Enclosure Panel Homeowner  
Clean as necessary following the directions provided in this  
manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS  
WHILE HOT.  
25  
I
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE  
FOR YOUR SAFETY READ BEFORE LIGHTING  
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLO-  
SION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INjURY OR LOSS OF LIFE.  
A. This appliance has a pilot which must be lit with a piezo  
igniter. When lighting the pilot, follow these instructions  
exactly.  
Do not use any phone in your building.  
Immediately call your gas supplier from a neighbor’s  
phone.  
If your gas supplier cannot be reached, call the fire depart-  
ment.  
B. BEFORE OPERATING smell all around the appliance area for  
gas. Ensure to smell next to the floor because some gas is  
heavier than air and will settle on the floor.  
C. Use only your hand to push in or turn the gas control knob.  
Never use tools. If the knob will not push in or turn by hand,  
do not try to repair it, call a qualified service technician. Force  
or attempted repair may result in a fire or an explosion.  
WHAT TO DO IF YOU SMELL GAS  
Extinguish any open flame.  
Open windows.  
Do not light any appliance.  
Do not touch any electrical switches.  
D. Do not use this appliance if any part has been under water.  
Immediately call a qualified service technician to inspect the  
appliance and to replace any part of the control system and  
any gas control which has been under water.  
LIGHTING INSTRUCTIONS  
1. STOP! Read the safety information above on this page.  
6. Wait five (5) minutes to clear out any gas. If you then smell gas,  
STOP! Follow “B” in the safety information above on this page. If you  
do not smell gas, go to the next step.  
2. Access the lower control compartment.  
3. Turn OFF/ON switch to “OFF” (and remote wall switch, if appli-  
7. Push in gas control knob slightly and turn counterclockwise  
cable).  
to “PILOT.”  
4. Verify main line shut-off valve is open.  
8. Push in control knob all the way and hold in. Immediately light the  
pilot by triggering the spark igniter (pushing the button) until pilot  
lights. Continue to hold the control knob in for about 1 1/2 minutes  
after the pilot is lit. Release knob and it will pop back up. Pilot should  
remain lit. If it goes out, repeat steps 5 through 8.  
5. Push in gas control knob slightly and turn clockwise  
to “OFF.”  
SIT Millivolt Gas Valve  
If knob does not pop up when released, stop  
and immediately call your service technician  
or gas supplier.  
I N  
O U T  
TP/TH  
TP  
H
F
O
P
I
L
O
W
T
TH  
If pilot will not stay lit after several tries,  
turn the control knob to “OFF” and call  
your service technician or gas supplier.  
O
N
I
T O  
Millivolt Pilot  
- LO / HI +  
GAS CONTROL  
KNOB  
9. Turn gas control knob counterclockwise  
BURNER  
OFF/ON SWITCH  
PIEZO  
IGNITER  
to “ON.”  
10. Close lower control compartment.  
Note: Knob cannot be turned from “PILOT” to “OFF”  
unless the knob is pushed in slightly. Do not force.  
TO TURN OFF GAS TO APPLIANCE  
1. Turn remote wall switch “OFF.” The pilot will remain lit for  
4. Depress gas control knob slightly and turn clockwise  
normal service.  
to “OFF.” Do not force.  
2. For complete shutdown, turn remote wall switch to “OFF.”  
5. Close lower control compartment.  
3. Access the lower control compartment.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT  
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE  
AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS à LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU  
UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.  
Appelez immédiatement votre compagnie de gaz en utilisant le télé-  
phone du voisin.  
A. Cet appareil est muni d’une veilleuse qui doit être allumée avec un  
allumeur piézo-électrique. Lorsque vous allumez la veilleuse, suivre  
exactement ces instructions.  
B. AVANTLALLUMAGE:Ensurez-vousquevousnedétectezaucuneodeur  
de gaz autour de l’apareil ainsi que près du sol; certains gaz, étant plus  
lourds que l’air, descendent au niveau du sol.  
S’il vous est impossible de contacter votre compagnie de gaz, appelez  
le service des incendies.  
C. N’utilisez que votre main pour manipuler le bouton de réglage du gaz.  
N’utilisez jamais d’outils. Si le bouton refuse de tourner ou de bouger,  
n’essayez pas de le réparer. Communiquez immédiatement avec un  
technicien de service qualifié. Toute tentative pour le forcer ou le  
réparer, risquerait de provoquer un incendie ou une explosion.  
D. Ne vous servez pas de cet appareil si l’un de ses éléments a été  
immergé dans l’eau. Appelez immédiatement un technicien compétent  
pour faire inspecter l’appareil et remplacer toute pièce du système de  
réglage ou commande du gaz qui a été sous l’eau.  
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE ODEUR  
DE GAZ:  
Éteignez toute flamme visible.  
Ouvrez les fenêtres.  
N’allumez aucun appareil.  
Ne touchez à aucun commutateur électrique.  
Ne vous servez d’aucun téléphone dans votre édifice.  
INSTRUCTIONS D'ALLUMAGE  
8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.  
Allumez immédiatement la veilleuse en déclenchant l’allume-gaz  
à étincelle (en poussant le bouton) jusqu’à ce que la veilleuse  
s’enflamme. Continuez de tenir le bouton de réglage enfoncé  
pendant environ 90 secondes après l’allumage de la veilleuse.  
Relâchez le bouton et il sortira subitement. La veilleuse devrait  
rester allumée. Si elle s’éteint, répétez les étapes 5 à 8 inclusive-  
ment.  
1. ARRÊTEZ! Lisez les consignes de sécurité au verso de cette plaque.  
2. Ouvrez le compartiment de contrôle du bas.  
3. Tournez l’interrupteur mural à la position d’arrêt “OFF”.  
4. Ensurez-vous que la soupape d’arrêt de la canalisation principale est  
ouverte.  
5. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans  
le sens des aiguilles d’une montre  
d’arrêt “OFF”.  
jusqu’à la position  
SIT Vanne Gaz Millivolt  
Si le bouton ne sort pas automatiquement après avoir été relâché,  
arrêtez immédiatement et téléphonez à votre technicien de service  
ou à votre fournisseur de gaz.  
I N  
O U T  
TP/TH  
TP  
H
F
O
P
I
L
O
W
T
Si la veilleuse refuse de rester allumée après plusieurs tentatives,  
tournez le bouton de réglage jusqu’à sa position d’arrêt “OFF” et  
téléphonez à votre technicien de service ou à votre fournisseur de  
gaz.  
TH  
O
N
I
T O  
- LO / HI + (COMMANDE  
DE TAILLE DE FLAMME)  
BOUTON DE RÉGLAGE DU GAZ  
ALLUMEUR  
9. Tournez le bouton de réglage du gaz en sens inverse des aiguilles  
Interrupteur  
(OFF/ON)  
d’une montre  
jusqu’à sa position de marche “ON”.  
10. Fermez le compartiment de contrôle du bas.  
11. Au besoin, rebrancher l’appareil au  
courant électrique et remettre  
Millivolt Pilot  
l’interrupteur du brûleur principal  
à la position “ON” ou régler le  
Remarque: Il est impossible de tourner le bouton de “PILOT” à “OFF” à  
moins qu’il ne soit légèrement enfoncé. Ne le forcez pas.  
0thermostat à la température désirée.  
12. Si l’appareil ne fonctionne pas,  
suivre les instructions intitulées  
“Pour fermer le gaz qui alimente  
l’appareil” et appeler un technicien  
ou le fournisseur de gaz.  
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous décelez  
une odeur de gaz, ARRÊTEZ ! Retournez au point “B” des consignes  
de sécurité au verso de cette plaque. Si vous ne remarquez aucune  
odeur de gaz, passez à l’étape suivante.  
7. Enfoncez légèrement le bouton de réglage du gaz et tournez-le en  
sens inverse des aiguilles d’une montre jusqu’à la position de veil-  
leuse  
“PILOT”.  
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL  
1. Tournez l’interrupteur mural à la position d’arrêt “OFF”. La veilleuse  
4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans  
restera allumée jusqu’au retour du service normal.  
le sens des aiguilles d’une montre  
jusqu’à la position  
d’arrêt “OFF”. Ne forcez pas le bouton.  
2. Pour une fermeture complète, tournez l’interrupteur mural à la posi-  
tion d’arrêt “OFF”.  
5. Fermez le compartiment de contrôle du bas.  
3. Ouvrez le compartiment de contrôle du bas.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIGHTING INSTRUCTIONS — ELECTRONIC  
FOR YOUR SAFETY READ BEFORE LIGHTING  
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY  
RESULT CAUSING PROPERTY DAMAGE, PERSONAL INjURY OR LOSS OF LIFE.  
A. When lighting the appliance, follow these instructions  
Immediately call your gas supplier from a neighbor’s  
exactly.  
phone.  
If your gas supplier cannot be reached, call the fire  
B. BEFORE OPERATING smell all around the appliance area  
for gas. Be sure to smell next to the floor because some  
gas is heavier than air and will settle on the floor.  
department.  
C. Use only your hand to turn the gas control lever. Never  
use tools. If the lever will not turn by hand, do not try  
to repair it, call a qualified service technician. Force or  
attempted repair may result in a fire or an explosion.  
WHAT TO DO IF YOU SMELL GAS  
Extinguish any open flame.  
Open windows.  
D. Do not use this appliance if any part has been under  
water. Immediately call a qualified service technician  
to inspect the appliance and to replace any part of the  
control system and any gas control which has been under  
water.  
Do not light any appliance.  
Do not touch any electrical switches.  
Do not use any phone in your building.  
LIGHTING INSTRUCTIONS  
1. STOP! Read the safety information above on this page.  
2. Turn remote wall switch to “OFF.”  
5. Turn the ON/OFF switch to “OFF”. Do not force.  
6. Wait five (5) minutes to clear out any gas. If you then  
smell gas, STOP! Follow “B” in the safety information  
above on this page. If you do not smell gas, go to the  
next step.  
3. Open lower control compartment door.  
4. Verify main line shut-off valve is open.  
7. Turn the ON/OFF switch to “ON”. Do not force.  
ON/OFF Switch  
8. Turn “ON” all electrical power to appliance (remote wall  
switch).  
9. Close lower control compartment door.  
TO SHUT OFF  
1. Turn off all electrical power to the appliance (remote wall  
switch).  
Front View  
TO TURN OFF GAS TO APPLIANCE  
1. For complete shut-down, turn remote wall switch to  
3. Turn the ON/OFF switch to “OFF”. Do not force.  
4. Close the main line shut-off valve.  
“OFF.”  
2. Open lower control compartment door.  
5. Close lower control compartment door.  
28  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTIONS D’ALLUMAGE — ELECTRONIC  
POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE  
AVERTISSEMENT:SIVOUSNESUIVEZPASCESINSTRUCTIONSàLALETTRE,ILPOURRAITS’ENSUIVREUNINCENDIEOUUNE  
EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE.  
A. Lorsquevousallumezl’appareil,suivezexactementcesinstruc-  
Appelez immédiatementvotre compagnie degazenutilisant  
le téléphone du voisin.  
tions.  
S’il vous est impossible de contacter votre compagnie de  
gaz, appelez le service des incendies.  
B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détectez  
aucune odeur de gaz autour de l’apareil ainsi que près du sol;  
certains gaz, étant plus lourds que l’air, descendent au niveau  
du sol.  
C. N’utilisez que votre main pour manipuler linterrupteur “ON/  
OFF” de la valve à gaz. N’utilisez jamais d’outils. Si  
l’interrupteur ne bouge pas manuellement, n’essayez pas de le  
réparer. Communiquez immèdiatement avec un technicien de  
service qualifié. Toute tentative pour forcer l’interrupteur ou le  
réparer, risquerait de provoquer un incendie ou une explosion.  
VOICI CE QUE VOUS DEVEZ FAIRE SI VOUS DÉCELEZ UNE  
ODEUR DE GAZ  
Éteignez toute flamme visible.  
Ouvrez les fenêtres.  
D. Ne vous servez pas de cet appareil si l’un de ses éléments a  
été immergé dans l’eau. Appelez immédiatement un technicien  
compétent pour faire inspecter l’appareil et remplacer toute  
pièce du système de réglage ou commande du gaz qui a été  
sous l’eau.  
N’allumez aucun appareil.  
Ne touchez à aucun commutateur électrique.  
Ne vous servez d’aucun téléphone dans votre édifice.  
INSTRUCTIONS D’ALLUMAGE  
1. ARRÊTEZ ! Lisez les consignes de sécurité au verso de cette  
6. Attendez cinq (5) minutes pour l’evacuation du gaz. Si vous  
décelez une odeur de gaz ARRÊTEZ ! Retournez au point “B”  
des consignes de sécurité au verso de cette plaque. Si vous ne  
remarquez aucune odeur de gaz, passez à l’étape suivante.  
plaque.  
2. Tournez l’interrupteur mural à la position d’arrêt “OFF”.  
7. Tournez la manette de réglage du gaz jusqu’à la position de  
3. Ouvrez la porte du compartiment de contrôle du bas.  
marche “ON”. Ne la forcez pas.  
4. Assurez-vousquelasoupaped’arrêtdelacanalisationprincipale  
8. Ouvrez le courant électrique (“ON”) qui alimente l’appareil  
est ouverte.  
(interrupteur mural).  
9. Fermez la porte du compartiment de contrôle du bas.  
5. Tournez la manette de réglage du gaz à la position d’arrêt “OFF”.  
Interrupteur  
ON/OFF  
10. Au besoin, rebrancher l’apareil au courant électrique et  
remettre l’interrupteur principal du brûleur à la position “ON”  
ou régler le thermostat à la température désirée.  
11. Si l’appareil ne se met pas en marche, suivre les instruc-  
tions intitulées “Pour fermer le gaz qui alimente l’appareil” et  
appeler un technicien ou le fournisseur de gaz.  
POUR ÉTEINDRE LAPPAREIL  
1. Coupez tout le courant électrique qui alimente l’appareil (inter-  
Vue de face  
rupteur mural).  
POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL  
1. Pour une fermeture complète, tournez l’interrupteur mural à la  
3. Tournez la manette de réglage du gaz à la position d’arrêt “OFF”.  
position d’arrêt “OFF”.  
Ne la forcez pas.  
2. Ouvrez la porte du compartiment de contrôle du bas.  
4. Fermez la soupape d’arrêt de la canalisation principale.  
5. Fermez la porte du compartiment de contrôle du bas.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM  
Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in  
the “ON” position.  
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.  
POSSIBLE CAUSES  
SYMPTOM  
CORRECTIVE ACTION  
1. Spark ignitor will not light  
pilot after repeated triggering  
of ignitor button.  
Checkforsparkatelectrodeandpilot;ifnosparkandelectrode  
wire is properly connected, replace ignitor.  
A. Defective ignitor  
(no spark at electrode).  
Using a match, light pilot. If pilot lights, turn off pilot and trig-  
ger the ignitor button again. If pilot lights, an improper gas  
mixture caused the bad lighting and a longer purge period is  
recommended.Ifpilotwillnotlightcheckgapatelectrodeand  
pilot – should be 1/8" to have a strong spark. If gap measures  
1/8", replace pilot (Figure 11 on page 16).  
B. Defective or misaligned electrode  
at pilot (spark at electrode).  
C. Gas supply pressure errant.  
Check inlet gas pressure. It should be within the limits as  
marked on the rating plate.  
D. Pilot orifice plugged.  
Clean or replace pilot orifice.  
Check pilot flame, it must impinge on thermocouple (Figure  
11 on page 16) Clean and/or adjust pilot for maximum flame  
impingement on thermocouple. Ensure that the connection  
between the valve and thermocouple are tight and secure.  
2. Pilot will not stay lit after  
carefully following the light-  
ing instructions.  
A. Defective pilot generator  
(thermocouple).  
3. Pilot burning, no gas to  
burner, Valve knob “ON,”  
Wall Switch “ON.”  
A. Wall switch or wires defective.  
Check wall switch and wires for proper connections. Jumper  
wire across terminals at wall switch, if burner comes on, re-  
place defective wall switch. If okay, jumper wires across wall  
switch wires at valve, if burner comes on, wires are faulty or  
connections are bad.  
Check thermopile with millivolt meter. Take reading at thermo-  
pileterminalsofgasvalve.Shouldread325millivoltsminimum  
with optional wall switch “OFF.” Replace faulty thermopile if  
reading is below specified minimum.  
B. Thermopile may not be generating  
sufficient millivoltage.  
C. Plugged burner orifice.  
Check burner orifice for stoppage and remove.  
Clean and/or adjust pilot flame for maximum flame impinge-  
ment on thermocouple (Figure 11 on page 16).  
4. Frequent pilot/burner outage  
A. Pilot flame may be too low or  
blowing (high) causing the pilot/  
valve safety to drop out.  
problem.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM  
Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in  
the “ON” position.  
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.  
SYMPTOM  
POSSIBLE CAUSES  
CORRECTIVE ACTION  
1. Burner will not light.  
A. Faulty Valve System.  
See Below.  
B. “OFF/ON” or wall switch  
Disconnect the two black wires from the wire nuts. Test switch(s) for continu-  
ity with a multimeter. If continuity is not indicated, switch(s) is defective and  
must be replaced.  
defective.  
Note: Before replacing “OFF/ON” switch, be sure to check wiring for loose  
connections or broken wires and repair as needed.  
2. Burners come “ON” but  
A. Burner orifice plugged.  
Check main burner orifice(s) for stoppage. Clean or replace.  
Check vent system for obstructions.  
go “OFF.”  
B. Obstructed vent system.  
START  
CHECK  
• Check For Proper Voltage At Control Harness  
(See Insert A). Voltage Should Be 24V  
Between Thermostat Or Pressure Switch  
• Turn Off Gas Supply  
• Line Voltage Power  
• Low Voltage Transformer  
• Limit Controller  
• Thermostat  
NO  
• Assure Valve Switch Is In ON Position  
• Disconnect Control Harness  
• Set Thermostat To Call For Heat  
And 24V Common And 24V Hot.  
2
• Wiring  
YES  
• Plug Control Harness Into Valve. Wait For  
Internal Check Delay.  
• With Pilot Burner Cable Connected, Measure  
Voltage At Valve HSI Element Output. 24V  
Nominal. (See Insert B)  
NO  
NO  
• Igniter Warms Up And Glows Red.  
• Replace Valve.  
Insert A  
End View Of  
Control Harness  
Connector  
1
2
24 Volt Hot  
YES  
24 Volt  
Common  
1
YES  
• Replace Igniter/Flame Rod Assembly.  
YES  
24 Volt  
Switched  
NO  
NO  
• Check That Pilot Gas Is Flowing. Wait To  
Assure Plot Gas Tubing Is Purged. Recycle  
Call For Heat If Necessary.  
• Replace Valve.  
• Turn On Gas Supply. • Pilot Burner Lights.  
Check For Damaged Or Missing Terminals  
In Connector  
YES  
• Measure Voltage Between 24V Hot And 24V Common  
Leads To Valve Control. Must Measure At Least 19.5  
VAC With Igniter Powered (See Insert A). To Identify  
Proper Lead, This Check Must Be Done With The  
Valve Control Connected And Igniter Powered.  
NO  
• Check Transformer And  
Line Volt Supply.  
Insert B  
YES  
Igniter Terminals  
YES  
• Replace Pilot Assembly.  
• Check That Pilot Flame Makes Good Contact With  
Pilot Burner Flame Rod.  
NO  
• Check For Good Electrical Connection Through The  
Pilot Tubing.  
• Main Valve Opens And Main Burner Lights.  
• If Both Of The Above Are Good, Replace Igniter/Flame  
Rod Assembly.  
YES  
YES  
• Cycle Thermostat Off And Back On.  
• System Is Okay.  
Igniter Will Cycle Off And Back On Once During  
When Measured Voltage At Connections, Use  
Care To Assure Terminals Are Not Damaged.  
NO  
1
2
• Main Burner Lights.  
• Replace Valve.  
The 90 Second Ignition Trial. All Voltage  
Measurements Must Be Taken While The Igniter  
Is Powered.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPLACEMENT PARTS LIST  
Natural and Propane  
No. DESCRIPTION  
Part No.  
Qty.  
Qty.  
Qty.  
Qty.  
EDVST  
EDVPF  
EDVCL  
EDVCR  
1a Upper Radiant, Black - 24 in.  
1b Upper Radiant, Black - 40 in.  
2a Hood, Black - 24 in.  
H3723  
H3722  
98K95  
97K52  
H3743  
H3741  
H3725  
H3724  
H3731  
H3729  
H3733  
H3732  
12L15  
55M04  
H3358  
H3876  
55M42  
19L51  
43K85  
42M80  
H3386  
H3385  
H3388  
H3387  
69L21  
69L31  
80L41  
H3707  
93L32  
none  
1
2
1
1
1
1
2
none  
1
1
1
2b Hood, Black - 40 in.  
2
2
1
1
3a Upper Bustle, Black - 24 in.  
3b Upper Bustle, Black - 40 in.  
4a Glass Enclosure Assembly - 24 in.  
4b Glass Enclosure Assembly - 40 in.  
5a Lower Bustle, Black - 24 in.  
5b Lower Bustle, Black - 40 in.  
6a Lower Radiant Assembly, Black - 24 in.  
6b Lower Radiant Assembly, Black - 40 in.  
none  
1
1
1
2
2
1
1
none  
1
1
1
2
2
1
1
none  
1
1
1
2
2
1
1
none  
1
1
1
2
2
1
1
7
8
9
Nameplate (Brand)  
Log Set  
2
2
1
1
1
1
1
1
Grate Assembly  
1
1
1
1
10 Magnet, Radiant Panel  
11 Burner Assembly  
2
4
3
3
1
1
1
1
12 Gasket, Burner Tray Mounting  
13 Gasket, Venturi Tube Mounting  
14 Venturi Tube Arm  
1
1
1
1
1
1
1
1
1
1
1
1
Millivolt  
15a  
none  
1
1
none  
none  
1
Modesty Panel - PF, CL  
15b  
Electronic  
none  
1
1
15c  
Millivolt  
1
1
4
2
1
1
1
none  
none  
6
none  
none  
4
Modesty Panel - ST, CR  
15d  
Electronic  
1
16 Latch, Glass Enclosure Panel  
17 Magnet, Latch, Spring-Loaded  
18 Switch, Rocker  
4
2
1
1
1
1
1
19 Air Shutter Adjustment Rod  
20 Flex Line Gas Connector  
1
1
1
1
1
1
Note: Ordering information for Volcanic Stone, Glowing Embers and Touch-up Paint can be found on Page 19.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPLACEMENT PARTS LIST CONTINUED  
GAS CONTROLS — SIT MILLIVOLT  
Natural  
Propane  
Part No.  
No.  
DESCRIPTION  
Part No.  
43K07  
10K86  
69L17  
60J79  
74L57  
74L56  
74L58  
21L81  
31L22  
Qty.  
1
Qty.  
1
30.  
31.  
32.  
33.  
34.  
35.  
36.  
37.  
38.  
Gas Valve - SIT  
Piezo Igniter  
88J53  
10K86  
69L18  
60J79  
74L57  
74L56  
74L58  
21L82  
31L22  
1
1
Pilot Assembly  
Pilot Generator  
Thermocouple  
Pilot Tube  
1
1
1
1
1
1
1
1
Electrode And Cable  
Orifice  
1
1
1
1
Sticker (Modesty Panel)  
1
1
GAS CONTROLS — HONEYWELL ELECTRONIC  
Natural  
No.  
DESCRIPTION  
Part No.  
62L18  
62L14  
42J32  
87L54  
21L81  
69L50  
H3720  
Qty.  
1
40.  
41.  
42.  
43.  
44.  
45.  
46.  
Gas Valve - Honeywell  
Pilot Assembly  
Transformer  
1
1
Ignitor Assembly (Kit)  
Orifice  
1
1
Sticker (Modesty Panel)  
Pilot Tube  
1
1
Contact an Authorized Lennox Hearth Products dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts  
can result in poor performance and safety hazards.  
WARNING  
AVERTISSEMENT  
Failure to position the parts in accordance with these  
diagrams or failure to use only parts specifically  
approved with this appliance may result in property  
damage or personal injury.  
Risque de dommages ou de blessures si les pièces  
ne sont pas installées conformément à ces schémas  
et ou si des pièces autres que celles spécifiquement  
approuvées avec cet appareil sont utilisées.  
33  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPLACEMENT PARTS  
EDVPF Shown - see table on page 30 and 31  
for replacement parts applicable to  
EDVST, EDVCR and EDVCL  
Cabinet  
Firebox  
8
17  
15a  
15b  
16  
12  
13  
10  
9
31  
38  
45  
33  
34  
18  
14  
36  
1b  
2b  
32  
3b  
11  
20  
4b  
19  
35  
30  
5b  
37  
44  
6b  
7
42  
1a  
2a  
40  
3a  
4a  
43  
5a  
6a  
41  
46  
34  
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design,  
materials, specifications, prices and also to discontinue colors, styles and products.  
Consult your local distributor for fireplace code information.  
Printed in U.S.A. © 2003 Lennox Hearth Products  
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210  
P/N 875022M REV. F 01/2011  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Land Pride Spreader PS2096 User Manual
Learning Resources Baby Toy LER 2019 User Manual
Lenovo Computer Monitor L1711P User Manual
LG Electronics DVD Player DP170 User Manual
Magnavox Car Stereo System AZ 8068 User Manual
Magnavox VCR MVR440MG 17 User Manual
Makita Caulking Gun BCG180 User Manual
Margaritaville Gas Grill NBMGLG1000 User Manual
Mark Feldstein Assoc Home Theater System SP4080 User Manual
Maytag Dishwasher MDB4949SD User Manual