LENNOX HEARTH PRODUCTS
KITS AND ACCESSORIES
775202M
Rev. A, 01/2011
AIR CIRCULATION BLOWER kIT
MODEL VINT-TET BLWR, CAT. NO. 75194
INSTALLATION INSTRUCTIONS FOR AN AIR CIRCULATION
BLOWER kIT FOR USE WITh ThE VINTAGE™ 27 GAS STOVE
TURN OFF ThE STOVE AND ALLOW IT TO COMPLETELY COOL BEFORE
PROCEEDING.
kIT CONTENTS
1 ea. Blower Assembly (item #1)
2 ea. Washers, #10 (item #2)
2 ea. Nuts, 10-24 Nylock (item #3)
1 ea. Instruction Sheet
INSTALLATION INSTRUCTIONS
Step 1. Using an allen wrench, remove socket head screw A that secures the
heat shield to the bottom of the stove. See Figure 2.
Step 2. Using pliers, twist and break off section B of the heat shield (shown
as hatched section B in Figure 2). Discard this piece after removing.
1
3
2
Figure 1 - Kit Contents
A
B
TOOLS NEEDED
5/32” Allen Wrench Or T-Handle Wrench
3/8” End Wrench
Pliers
A
GENERAL INFORMATION
B
This optional 150-CFM blower for the Vintage gas stove provides variable
speed control, thermal activation and forced air circulation of the warm air
into the room.
1. Remove
Screw A
B
If you encounteranyproblems, needclarificationof theseinstructions orare
notqualifiedtoproperlyinstallthiskit, contactyoulocaldistributorordealer.
2. Remove Section B
and Discard
Read this instruction sheet in its entirety before beginning the installation.
ALL WARNINGS AND PRECAUTIONS IN ThE INSTALLATION AND OPERA-
TION MANUAL PROVIDED WITh ThE APPLIANCE APPLY TO ThESE
INSTRUCTIONS.
Figure 2
1
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Download from Www.Somanuals.com. All Manuals Search And Download.
Blower Operation
WARNINGS
The blower will come on when the stove is up to temperature and shut
off when the stove cools. The blower control knob must be turned “ON”
for the blower to operate (see Figure 6).
Once the new blower is properly installed, it must be
plugged directly into a properly grounded three-prong
receptacle, 120 VAC, 60 hz, single phase power supply.
Donotcutorremovethegroundingprongfromthisplug.
Do not route power cord under or in front of appliance.
Blower Control knob - The highest blower speed is obtained by turning
the control knob clockwise until it clicks “ON.” Continue to rotate the knob
clockwise for a lower speed. To turn off, rotate the knob counterclockwise
until it clicks “OFF.”
Ground supply (green) lead must be connected to the
wire attached to the green ground screw located on the
unit or blower assembly. Failure to do so will result
in a potential safety hazard. The appliance must be
electrically grounded in accordance with local codes
or, in the absence of local codes, the National Electri-
cal Code, ANSI/NFPA 70-latest edition. (In Canada, the
current CSA C22-1 Canadian Electrical Code).
Left Side of Stove
CAUTIONS
• Disconnect the plug from receptacle prior to servicing the
blower.
Blower
Control knob
• Labelallwirespriortodisconnectionwhenservicingcontrols.
Wiring errors can cause improper and dangerous operation.
• Verify proper operation after servicing.
Figure 6 - Blower Control Knob
Vintage™ 27 Blower Wiring Diagram
Blower Snap Switch - N/O
Blower Speed Control
Control knob
Speed Control
Wire (Red)
Snap Switch
Connection Wire
(Black)
Speed Control Wire (Red)
Speed Control
Connection Wire (Black)
BLOWER
Main Power Cord
Wire (Black)
Ground Wire
(Green)
Main Power Cord
Wire (White)
N/O - Normally Open (Contacts
Close When Stove Is hot)
Main Power Cord
Wire (Black)
Figure 7 - Wiring Diagram
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Lennox Hearth Products reserves the right to make changes at any time, without notice, in
design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2010 Lennox hearth Products
1508 Elm hill Pike, Suite 108 • Nashville, TN 37210
4
P/N 775202M REV. A 01/2011
Download from Www.Somanuals.com. All Manuals Search And Download.
|