1.3. ESD Precautions
1. INTRODUCTION
It is recommended that you fit and check a suitable anti-static wrist or
ankle strap and observe all conventional ESD precautions when handling
plug-in modules and components. Avoid contact with backplane compo-
nents and module connectors, etc.
1.1. Safe Handling
An enclosure can weigh up to 36kg (79.2lb). Do not try to lift it by
yourself.
1.4. Rack System Precautions
Do not lift the enclosure by the handles on the Battery Modules.
They are not designed to take the weight.
The following safety requirements must be considered when the unit is
mounted in a rack.
1.2. Safety
The rack design should incorporate stabilizing features suitable to
prevent the rack from tipping or being pushed over during installa-
tion or in normal use.
All plug-in modules and blank plates are part of the fire enclosure and
must only be removed when a replacement can be immediately added.
The system must not be run without all units in place. In order to com-
ply with applicable safety, emission and thermal requirements no covers
should be removed.
When loading a rack with the units, fill the rack from the bottom up
and empty from the top down.
The rack design should take into consider-ation the maximum op-
erating ambient temperature for the unit, which is 35°C.
Permanently unplug the unit if you think that it has become damaged in
any way and before you move it.
The system must be operated with low pressure rear exhaust instal-
lation (back pressure created by rack doors and obstacles not to
exceed 5 pascals (0.5mm water gauge)).
The unit must only be operated from a power supply input voltage
range of 100-240 VAC, 50-60 Hz.
The rack should have a safe electrical distribution system. It must
provide over-current protection for the unit and must not be over-
loaded by the total number of units installed in the rack. Consid-
eration of the electrical power consumption rating shown on the
unit’s nameplate should be used when addressing these concerns.
The plug on the power supply cord is used as the main disconnect
device. Ensure that the socket outlets are located near the equip-
ment and are easily accessible.
The power connection must always be disconnected prior to re-
moval of a PSU module from the enclosure.
The electrical distribution system must provide a reliable earth for
each unit in the rack.
A safe electrical earth connection must be provided to the power
cord. Check the grounding of the enclosure before applying power.
Provide a suitable power source with electrical overload protection
to meet the requirements laid down in the technical specification.
Each power supply in each unit has an earth leakage current of
0.75mA. The design of the electrical distribution system must take
into consideration the total earth leakage current from all the power
supplies in all the units. The rack will require labelling with “HIGH
LEAKAGE CURRENT. Earth connection essential before connecting
supply”.
This equipment is intended to operate with two working PSUs in-
stalled in the Power Supply Module. Before removal/replacement
of a PSU disconnect all power for isolation.
A faulty PSU must be replaced with a fully operational one within
24 hours.
The rack, when configured with the units, must meet the safety re-
quirements of UL 60950-1 and IEC 60950-1.
CAUTION: If this equipment is used in a manner not specified by LaCie,
the protection provided by the equipment may be impaired.
2. PREPARATION
IMPORTANT INFO: The enclosure top cover must be secured, when the
enclosure is in normal use, by rotating the lock 90° to the ‘locked’ posi-
tion. This is to prevent users/operators from accessing the service areas.
2.1. Before You Begin
Before you begin, make sure the site where you intend to set up and use
your enclosure has the following:
CAUTION: The RJ45 sockets on the motherboard/PCI cards are for Eth-
ernet connection only and must not be connected to a telecommunica-
tions network.
Standard power from an independent source or a rack power dis-
tribution unit with a UPS.
Power Cord
IMPORTANT INFO: Do not remove covers from the PSU. Danger of
electric shock inside. Return the PSU to LaCie for repair.
Rack kit (if installing within a rack)
Refer to LaCie for a list of qualified accessories for use with the enclosure.
The Accessory Box contains the power cords and other ordered acces-
sories.
IMPORTANT INFO: Bifurcated power cords must NOT be used with the
12big Rack Storage Server.
LaCie Quick Install Guide
3
Download from Www.Somanuals.com. All Manuals Search And Download.
2.2. Unpacking
3. INSTALLATION
1. Inspect the packaging for crushes, cuts, water damage or any other
evidence of mishandling during transit. If any damage appears pres-
ent, photograph the packaging before opening, for reference.
3.1. Mounting the System into a Rack
2. Unpack the system. See Figure 1.
NOTE: The rail kit is suitable for 19” racks with square and round holes
only. The minimum distance between vertical rack posts is 24” (610mm);
the maximum distance is 36” (914mm). The rail location pins are pre-
assembled to suit square hole or round hole racks. The pins should not
be removed.
1. Remove the Rack Mounting Rail Kit from the Accessory Box and
check for damage.
2. Ensure the pre-assembled rails are at their shortest length.
3. Locate the rail location pins inside the front of the rack and extend
the rails to enable the rear location pins to engage. Ensure the pins
are fully located in the holes in the rack posts (see Figure 2).
4. Install the front and rar clamping screws (see Figure 2). The screws
should be left loose enough to allow the rail to move sideways on
its slots.
5. Slide the enclosure fully home on its rails.
6. Withdraw the enclosure approximately 200mm and fully tighten the
front and rear clamping screws (see Figure 2).
7. Fasten the front of the enclosure using the two captive screws a
shown in Figure 2.
Figure 1 - Unpacking the Enclosure
Figure 2 - Rack Installation
LaCie Quick Install Guide
4
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2. Fitting Modules
3.4. Removing PSUs
Fit the modules into the bays defined in Figure 3.
IMPORTANT INFO: Prior to removing the PSU from the mounting cage,
please disconnect the power from the power supply, by either the switch
(where present) or by physically removing the power source, to ensure your
system has warning of an imminent power shutdown. Do not remove the
faulty PSU unless you have a replacement ready for insertion.
IMPORTANT INFO: The removal of the enclosure top cover or a PSU
module must only be performed by service personnel. Potential hazards
include rotating fans and hot surfaces. The screws or latches securing the
enclosure top cover and PSU modules must be firmly tightened to prevent
unauthorized access to those areas.
You can continue working while replacing the faulty PSU.
1. Make sure you identify the faulty PSU correctly from the two installed.
2. Switch off and disconnect the power supply cord.
3. Squeeze retaining handle to the left to release (see Figure 4a).
4. Grip the handle and withdraw the PSU (Figure 4b).
Figure 3: Module Locations
3.3. Fitting PSUs
Two PSUs are installed in the mounting cage at the rear of the enclosure.
Figure 4a: Removing a PSU
IMPORTANT INFO: Do not remove covers from the PSU. Danger of
electric shock inside. Return the PSU to LaCie for repair.
1. Check for damage, especially to the rear connector on the PSU.
2. Handle the PSU carefully and avoid damaging the connector pins.
Do not install the PSU if any pins appear to be bent.
3. Slide the PSU into the mounting cage.
4. Push firmly until a click is heard as the securing spring engages.
NOTE: This module must only be removed by service personnel.
5. You are now ready to connect the power supply cords to the power
sources and switch the power supply ON.
Figure 4b: Removing a PSU
LaCie Quick Install Guide
5
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Check the Fan for damage. Do not install it if there are any visible
signs of damage.
3.5. Replacing a Fan
4. Replace the Fan by pushing it all the way into the enclosure until it fits
firmly and is level with the other Fans.
IMPORTANT INFO: The cover must only be opened by service person-
nel.
5. Ensure that the Fan module LED extinguishes within 10 seconds of
installation.
1. Release the enclosure top cover by turning the lock mechanism to
the ‘Unlocked’ position and slide the cover back until it stops (see
Figure 5).
6. Close the enclosure cover and secure by turning the lock mechanism
to the ‘Locked’ position.
3.6. Battery Safety
Replacing batteries on the motherboard.
CAUTION: There is a danger of explosion if the battery is replaced by
an incorrect type.
Dispose of used batteries in accordance with the manufacturer’s instruc-
tions and national regulations.
CAUTION: The batteries on the NVRAM card(s) are not replaceable; the
complete card assembly must be replaced in the event of battery failure.
Therefore the complete card assembly must be replaced annually or in the
event of battery failure.
Figure 5: Removing the Enclosure Cover
3.7. Fitting Drives
2. Grip the faulty Fan module with finger and thumb and pull it
upwards in order to unplug it, and remove it from the enclosure
(see Figure 6).
CAUTION: Operation of the enclosure with ANY drive carrier modules
missing will disrupt the airflow and the drives will not receive sufficient
cooling. It is essential that all apertures are filled before operating the unit.
Dummy drive carrier modules are available for fitting to unused drive bays.
1. Release the carrier handle by pressing the latch in the handle to-
wards the right and insert the carrier into the enclosure.
IMPORTANT INFO: Ensure that the carrier is orientated so that the drive
is uppermost and the handle opens from the left (See Figure 7).
2. Slide the carrier, gently, all the way into the enclosure.
3. Cam the carrier home - the camming foot on the base of the carrier
will engage into the slot in the enclosure.
4. When the carrier is fully home, close the handle - a click should be
heard as the latch engages.
IMPORTANT INFO: Ensure that all drive carriers are fully engaged in
the enclosure by firmly pushing each one home fully into the slot (See
Figure 8).
Figure 6: Removing a Fan
IMPORTANT INFO: To avoid injury, ensure that the blades have stopped
rotating before handling the fan.
LaCie Quick Install Guide
6
Download from Www.Somanuals.com. All Manuals Search And Download.
3.8. Operator Panel
LED
Color
Normal
Fault
On
Power On
Fault
Green
Amber
Blue
On
Off
On
Enclosure ID
N/A
N/A
Figure 7: Drive Carrier Module (Note: ensure that the handle always
opens from the left.)
Figure 9: Operator Panel
Figure 8: Fitting Drives (Note: ensure the carriers are fully engaged in
the enclosure.)
LaCie Quick Install Guide
7
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2. Migrating your RAID
configuration
4. MANAGING YOUR RAID
Out of the box, only three drives are pre-configured. The operating system
resides on these three drives. This section explains how you can add un-
configured drives to the current RAID array or migrate from a RAID 5 to a
RAID 6 configuration.
The 12big Rack Storage Server comes with a preconfigured RAID 5 array
on the three first data drives, which contain the operating system partition.
This chapter explains how you can migrate, expand, or reconstruct your
RAID. The operating system CD is provided if you wish to build a custom-
ized configuration from scratch.
CAUTION: Be sure to back up your data before you change the RAID
level.
4.1. Start up and log in
1. Connect a monitor, mouse, and keyboard to the 12big Rack Storage
Server and boot the system.
CAUTION: Migrating a RAID cannot be stopped and will disable any
2. Follow the steps in the Set Up Windows wizard, then log on as an
administrator.
other RAID operations during processing.
Password: LaCie12big (case sensitive)
1. Click the Logical tab in the left panel of the MegaRAID Storage Man-
ager window.
3. Start LSI MegaRAID management software from start menu or
desktop.
2. Select a drive group in the left panel of the window.
4. The LSI administration page will open. Select your server and click
Connect.
3. Select Go To > Drive Group > Modify Drive Group on the menu
bar, or right-click the virtual drive icon to access the Modify Drive
Group Wizard. The Modify Drive Group Wizard window appears.
Figure 12 - Change RAID Level
Figure 11 - LSI Startup Dialog Window
NOTE: In the standard default configuration, only the local server will
be displayed.
5. By default, the credentials are:
Login: Administrator
Password: LaCie12big
6. The main MegaRAID Storage Manager window will open. Under
the Physical tab, select the MegaRAID SAS 9280-4i4e board.
LaCie Quick Install Guide
8
Download from Www.Somanuals.com. All Manuals Search And Download.
4. On the Modify Drive Group Wizard screen, select the RAID level
that you want to change (“migrate”) the drive group to and click
Next. A screen states the number of drives that you have to add if
new RAID level that require more drives.
7. Click Yes to accept and complete the migration to the new RAID
level.
You can monitor the progress of the RAID level change by selecting Man-
age > Show Progress in the menu bar.
4.3. Create a RAID-Protected Disk
Array
This section explains how to configure additional drives with custom set-
tings.
1. Select Go To > Controller > Create Virtual Drive to start configur-
ing your RAID array. Select Advanced and press Next.
Figure 13 - Select Drives for RAID Configuration
5. Select the unconfigured drive or drives to add and click Next.
NOTE: The drive(s) you add must have the same capacity as or greater
capacity than the drives already in the drive group, or you will not be able
to change the RAID level.
Figure 15 - Create Virtual Drive wizard
2. Beneath the list of available drives, proceed as follows for each disk
array:
a. Select the drives you want to include in your array in Unconfig-
ured Drives view.
CAUTION: Your operating system is pre installed on the first three data
drives. Removing the RAID configuration of those drives will delete the
pre-installed operating system.
NOTE: You can select multiple drives by holding the Ctrl key.
b. Click the Add button to move the drives to the Available Arrays
pane. If you make an error, select the drive and click Remove.
Figure 14 - RAID Configuration Summary Screen
6. Review the configuration information. Click Back to modify or Finish
to accept the changes. A confirmation message appears since this
operation cannot be aborted.
LaCie Quick Install Guide
9
Download from Www.Somanuals.com. All Manuals Search And Download.
c. For each array to create, click the Create Array Group button.
5. Click Next when finished.
6. Review the configuration shown in the Virtual Disk Summary win-
dow. If you want to change something, click Back and change the
configuration parameters. Otherwise, click Finish to accept the con-
figuration and start the initialization process (unless you selected No
Initialization above).
4.4. Mount the Array
1. To access your drive configuration, launch Server Manager from
the Windows Start Menu and select Storage > Disk Management.
Figure 16 - Create Drive Group
3. When all arrays have been created, click Next.
4. In the Virtual Disk Properties screen, modify default settings as fol-
lows in order to achieve best performance:
a. RAID level: RAID 6 for the best protection and RAID 5 for the
best protection/cost-per-TB ratio).
b. Initialization state: Full initialization
c. Stripe size: 256KB minimum
d. Read policy: Always Read Ahead
e. Write policy: Always write back
Figure 18 - Windows Storage Management
f.
I/O policy: Direct IO
g. Access policy: Read Write
h. Disk cache policy: Enabled
2. The Initialize Disk window should appear. If not, right-click the de-
sired disk and select Initialize Disk.
i.
Click Create Virtual Drive for each one you want to create.
Settings might be modified using Update Virtual Drive button.
3. Select GPT if your volume is greater than 2TB (GUID Partition Table)
and click OK.
4. Right-click on the desired disk and select New simple volume.
5. When formatting is completed, the disk should appear as Healthy.
The logical volume is now mounted and should appear in your Windows
Explorer.
4.5. Share the volume
If you need assistance to configure SMB and NFS shares, please refer to
associated technical paper available on the LaCie website and on product
CD:
12big Rack Storage Server is delivered with pre installed Extreme Z-IP
to allow Mac compatibility and Time Machine backup configuration. For
more details, please refer to documentation available on product CD or
in Start Menu > Programs > Extreme Z-IP.
Figure 17 - Advance Settings
LaCie Quick Install Guide
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Contact Us
LaCie Asia
LaCie Germany
Am Kesselhaus 5
D-79576 Weil Am Rhein
LaCie Switzerland
Davidsbodenstrasse 15A
4004 Basel
25/F Winsan Tower
98 Thomson Road
Wanchai, Hong-Kong, China
LaCie Italy
Milano Business Park
LaCie United Kingdom
and Ireland
LaCie Australia
458 Gardeners Road
Alexandria, NSW 2015
Edificio B1
Via dei Missaglia 97
20142 Milano
LaCie Ltd, Power Road Studios
114 Power Road
Chiswick, London, UK W4 5PY
Ireland: [email protected]
LaCie Benelux
Vorstlaan /165 Bld du Souverain
B-1160 Brussels, Belgium
Elecom – Japan
LaCie USA
22985 NW Evergreen Pkwy
Hillsboro, OR 97124
LaCie Nordic
(Sweden, Denmark, Norway, Finland)
LaCie Canada
103 The East Mall, Unit 1
Sveavägen 90, 5tr
Toronto, Ontario
113 59 Stockholm, Sweden
LaCie Worldwide Export
17, rue Ampère
91349 Massy Cedex, France
LaCie France
17, rue Ampère
91349 Massy Cedex
LaCie Spain
C/ Núñez Morgado, 3, 5a pl.
28036 Madrid
Visit www.lacie.com for more information on LaCie products.
Copyright © 2011, LaCie
xxxxxx 110610
LaCie Quick Install Guide
11
Download from Www.Somanuals.com. All Manuals Search And Download.
|