Assembly drawing
Dimensions are in Inches and (mm)
28.000
(171.2)
16.000
(406.4)
1.245
(31.75)
A
C
L
B
H
5.000
(127)
21.000
(533.4)
19.000 12.000
(482.6) (304.8)
10.500
(266.7)
C
L
5.000
(127)
C
G
16.000
(406.4)
D
16.000
(406.4)
16.000
(406.4)
F
24.290
(616.97)
E
Description
2.331
(59.21)
A. Wall plates
B. Mounting brackets
C. Griplate™
G
H
D. Mounting hardware
E. M6 x 30 (mm) Phillip screws
F. Wood stud
1
G. 5/16” x 3” Lag screws and flat washers
H. Safety knobs
20.500
(520.7)
2
Fine tune tilt adjustments
1. M5 Phillips screws for fine
tension
2. M8 Hex nut coarse tension
NOTE: The 8 (mm) hex nut is for your
coarse tension adjustment and the 5 (mm)
screws are for your fine tension adjustment.
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Flat panel list
Acer
Eizo
Idex
PDP7859: M6 x 20
5420T: M8 x 30
PDM4260: M4 x 16
Akai
Electrograph
Ikegami
CTA42AR7A, PDP4247, PDP4290, PDP4294,
PDP5090, HPT500AN: M8 x 25 – ½” nylon spacers -
sleeves
DTS42W: M8 x 30 – ¼” nylon spacers (large)
DTS4230: M8 x 30 – ½” nylon spacers - sleeves
DTS42DD, DTS42GBDD, DTS42GB: M6 x 20
PTM4202: M5 x 20
Akira
Faroudja
Integra
EPM420, SV4201: M5 x 16
FPP42HD10, FPP50HD10: M4 X 16
PLA50V1: M4 X 16
Albatron
Fujitsu
JVC
PWV46AC: M6 x 20
4211, 4212, 4221, 4222, 4208, 4209, 4213, 4214, 4229,
4241 4242, 4233: M5 x 16
5001, 5002, 5003, 5004, P50XHA10, P50XCA11UH,
P50XHA30WS: M8 x 25 – flat washers
PDS6101, PDS6001, PDS6002: M8 x 30 – ½” Nylon
spacers - sleeves
GDV4200PZW, 4210, GDV4210PZWGA, 4211,
GMP420UG, GMV42UG, JVP042WV74, PD42WV74,
PD42WX84: M5 x 16
GDV500PZU, GDV501U, 502U: M8 X 30 – ½” nylon
spacers – sleeves
Barco
Cineversum 50: M8 x 20
BenQ
Gateway
LG Electronics
PDP7843E: M6 x 20 – ¼” nylon spacers (small)
PDP46W1: M6 X 12
GTWP42M102: M8 x 20, M8 x 35 – ¼” nylon spacers
(large)
Flatron MU40PA10B, MU40PA15B: M5 x 20- ¼” nylon
spacers
GATEWAY 42: M8 x 30 – ¼” nylon spacers
GATEWAY 46: M6 x 20
GATEWAY 50: M8 x 30 – ¼” nylon spacers
Flatron MN42PZ10, MN42PZ11, MU42PZ10,
MU42PZ11B, MU42PZ15B: M5 x 20
MU50PZ41, MU50PZ90: M5 x 20
Flatron MU60PZ10, MU60PZ11B, MU60PZ12B,
MU60PZ90V: M8 x 25
Cornea
MP4200, MP4204: M5 x 16
Helios
Dream Vision
Luce
4200: M8 x 20
Revolution One, Revolution Five: M4 x 16
PDTV4220A: M5 x 25 – ½” nylon spacers
Dukane
Hitachi
Marantz
P37: M6 x 12
P42: M6 x 12
P50: M8 x 20
32HDT20,CMP307XJ,CMP307XU,32HDT20
CMP401HDU, CMP402HDE, CMP402HDU,
CMP4120HDU,CMP4121,CMP4121HDU,CMP4201U,
CMP4202U, 42HDW10,42HDT20, 42HDT50, 42HDT55
M6 x 12
PD4280D, PD4282D, PD4290D, PD4292D,
PD4293: M4 x 20
PD4298HD: M6 X 20
Dwin
PD501OD, PD5020, PD5040:
CMP5000WXU, CMP5003WXU, 50HDT50, 50HDT55:
M8 X 20
HD50: M8 x 30 – ½” nylon spacers - sleeves
Max
EIKI
4600, 4600T: M6 x 20
5000: M8 x 30- ½” nylon spacers - sleeves
PLD42XU: M5 x 20 - ¼” nylon spacers (small)
NOTE: If your flat panel display is not listed, go to (page 8) to determine the thread pitch for your flat panel.
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Mitsubishi
Princeton Graphics
Tatung
AR3.4FTW,AR4.6PDP: M6 x 20
PD5010HD, PD5030: M4 x 16
P46T: M6 x 20
Monivision
Rainbow
Toshiba
42HP82: M4 X 16
PWV46AC, PD46W00: M6 x 20
Spectrum 3750: M6 x 20
PD42W, PD42W1: M8 X 30 – ½ ” nylon spacers
(large) - sleeves
50HP81: M8 X 30 – ½” nylon spacers (large) - sleeves
50HP82: M4 X 16
RCA
NEC
PR42300, PHD42600, PHD50300, PHD50400: M4 X 16
4200W, 4210W, M4A,MP2, PX42M3A, 42PD1W, PD2
M5A,M5G, 42MP1, 42PD1, PX42VM1A, PX42VP1A,
PX42VP2A, 42MP3, 42PD3, PX42VP3A, 42MP4,
42VP4A, 42MX2: M4 X 16, 5000W, PX50M5A, 50PD1,
PX50VP1A, PX50MX1A, 50MP1, 50MP2, 50PD2,
50VP2, 50MP3,
PHD50500: M8 X 20
Tredex
TXP4600: M6 x 20
Revox
V-Inc
E1042: M6 x 20
E1050: M8 x 20
50XM3: M4 X 16
Vizio P1, Vizio P4: M6 x 12
Norcent
Runco
Vidikron
46WGA850: M6 x 12
PL42C, CW42: M4 X 16
PL42CXPL50CX: M8 X 30, ½” Nylon spacers –
VPW420: M8 X 30, ½” Nylon spacers (large) - sleeves
sleeves
Orion
E1050, PL50C, PL50HDX, CW50MC: M8 X 20
VIEWSONIC
PM4202: M5 x 16
Sampo
VPW420: M8 x 30 – ½” nylon spacers - sleeves
VPW425: M8 x 30 – ¼” nylon spacers (large)
VPW450HD: M8 x 30 – ¼” nylon spacers (large)
VPW500: M8 X 20
PME42S6: M8 x 30 – ¼” nylon spacers (large)
PME42F61: M8 x 20, M8 x 35 – ¼” nylon spacers
(large)
Panasonic
VPW505: M8 x 30 – ¼” nylon spacers (large)
TC42P1, PT42PD3P, PT42PD1P, TC42P1F, PT37P1,
TH42PWD3, TH37PWD4UZ, PT37PD4, TH37PW5EX,
TH37PA20UP, TH42PD4UY, TH42PWD4EX, PT42P1,
42PD2, TH42PWD3U, TH42PHD5U, PT42PD3P,
PT42PD4, PT42PHD4P, TH42PWD5UY, TH42PW5UZ,
TH42PWD6UY, TH42PA20UP, TH42PL20E,
TH42PAX20, TH50PHD3U, PT50PD3P, PT50PHD4P,
TH50PHD3E, TH50PHW3, TH50PD4, TH50PHD5UY,
TH50PHD6UY, TH50PL20E, TH50TX20UP:
M8 X 30 – ½” Nylon spacers – sleeves
PME50X6: M8 x 30 – ¼” nylon spacers (large)
Yamaha
Samsung
PDM1: M8 x 30 – ½” nylon spacers - sleeves
PPM42S2, PPM42S3, SPL4225K, SPN4235, SPN4239:
SPK4215M, PK42P2S: M8 x 25 – ½” nylon spacers
PPM50H2, HPL5025K: M8 x 30 – ½” Nylon spacers -
sleeves
Zenith
DPDP40W, P40V22,DPDP40V, P40V24: M5 x 20 – ¼”
nylon spacers (small)
P42W22, P42W22B, P42W24P, P42W34P: P40V24:
PPM50H3, HPN5039: M8 x 25 – ½” nylon spacers
TH42PX20U, TH50PX20U: M8 X 70 – 1-1/2” Nylon
spacers
Sanyo
M5 x 20 – ¼” nylon spacers (small)
P50W26, P50W28, P50W38: M5 x 16
PDP421A: M5 x 20 - ¼” nylon spacer (small)
Philips
PDP42H1NA: M5 x 20 - ¼” nylon spacer (small)
NOTE: If your flat panel display is not
listed, go to (page 8) to determine the
thread pitch for your flat panel.
42FD9934, 42FD9952, 42FD9954, 42PH9555,
42FD9935: M5 x 25 ½” Nylon spacers
BDS4611: M6 x 20
Sharp
PZ42H2U, PZ43HV2U, PD50U, PZ50HV2U: M8 X 20
50FD9934/17S: M4 X 16
Pioneer
SONY
PDPV401, V402, PDP4330HD, PDP433HDE,
PDP433CMX, PDP433PU, PDP4300, PDP4340HD,
PRO800HD, PRO800HDI, PRO910HD, PDP4310,
PDP501X, V502MX, V502X, PDP503MX, V505,
PDP505HD, PRO1000HD, PDP503CMX, PDP5030HD,
PDP503HDE, PDP5031HD, PDP5040HD,
PFM42B1,PFM42B2: M6 x 20 - 5/16” flat washers
PFM-42V1,PFM-42V2: M6 x 20”- 5/16” flat washers
PFM50C1: M5 x 20 - 5/16” flat washers
KE-42XBR900: M5 x 20 - 5/16” flat washers
KE50XBR900: M5 x 20 - 5/16” flat washers
KE42XS910: M5 x 20 - 5/16” flat washers
KDE61XBR950: M5 x 20 - 5/16” flat washers
PRO1000HDI,PRO1110HD: M8 X 20
Planar
SVA
42N: M4 x 16
50P: M8 x 20
HD4208TIII: M6 x 20 - ¼” nylon spacers
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts list
NOTE: This wall mount is shipped with all proper installation hardware and components. Make sure that none of these parts are
missing before beginning installation. If there are parts missing stop the installation and contact Premier Mounts.
Actual screw size
(Qty 8)
(Qty 6)
M4 x 16
M4 x 25
M6 x 20
M6 x 30
(Qty 4)
(Qty 2)
(Qty 8)
M5 x 12
M5 x 16
M8 x 20
M8 x 25
(Qty 6)
(Qty 6)
(Qty 6)
M5 x 20
M5 x 25
M5 x 50
(Qty 6)
(Qty 4)
M8 x 30
(Qty 6)
(Qty 4)
(Qty 4)
M8 x 35
M8 x 70
(Qty 8)
M6 x 12
(Qty 4)
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts list (con’t)
Nylon spacers and flat washers
actual size
NOTE: The nylon spacers may be staked to achieve proper spacing.
9/16" Nylon spacers
(Qty 6)
1/4" Nylon spacers
(large)
(Qty 6)
1/2" Nylon spacers
(large)
Nylon sleeves
(Qty 4)
(Qty 12)
5/16" Flat washers
(metal)
(Qty 6)
1" Nylon spacers
(Qty 6)
1/4" Nylon spacers
(small)
(Qty 6)
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Checking the thread depth on your flat panel
1. Insert the thread depth
indicator (supplied)
through the thread inserts
found on the back of the
Figure 1
flat panel to make sure the
inserts measure the same
full depth and mark it.
(see figure 1)
2. Locate the correct
diameter screw for the
thread insert. Compare
your marking to the
screws (supplied). If your
selected screw is longer
than the marking on the
thread depth indicator DO
NOT USE this screw.
The screw length must not
bypass the marking. Select
Inverted flat panel
another screw size
display
(see figure 2 and 3). Until
you find one that comes
closest to your mark
without going past.
Marking the depth
Thread insert
Thread depth
indicator
Figure 2
Screw
Marking
Thread depth indicator
Figure 3
Screw
Marking
Thread depth indicator
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts list (con’t)
All of these parts are used to install the mounting bracket. Make sure that none of these parts are missing before beginning
installation. If there are parts missing stop the installation and contact Premier Mounts.
Level (1)
Griplates™ (8)
M6 x 12 Safety knobs (2)
Wall plates (2)
Mounting brackets
(left & right)
5/16" flat washers (8)
5/16" x 3" Lag bolts (8)
(used on wood studs
only)
M6 x 30 Lateral shift
locking screws (2)
Thread depth
indicator (1)
Template (1)
- 9 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Finding center of the flat panel display
WARNING : Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could
result in serious personal injury and possible damage to the flat panel.
WARNING!
INVERT THE FLAT PANEL PLACE IT ON A SOFT, FLAT SUFRACE TO PREVENT DAMAGE TO THE FLAT PANEL. USE A BLANKET, FOAM, ETC. FAILURE TO
DO SO WILL RESULT IN DAMAGING THE FLAT PANEL. DO NOT LAY THE FLAT PANEL ON THE FLOOR WITHOUT ANY PROTECTION TO THE GLASS. THE
FLAT PANEL IS HEAVY AND FRAGILE. AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT.
FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL.
Once the flat panel is inverted, use a measuring
tape to find the center of your flat panel measuring
from outside to outside of the chassis. See figure 1.
Top of flat
panel
C
L
Measuring
Inverted flat panel
tape
Bottom of flat
panel
Using a pencil lightly mark the center of your flat
panel.
See figure 2.
Inverted flat panel
C
L
Mark the center of
the flat panel
- 10 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Positioning the mounting brackets
CAUTION: Check the chart on page 4 and 5 to see if
your flat panel needs nylon spacers. The nylon spacers
provided, must be used. Failure to do so will result in
damaging the flat panel.
Nylon spacers if
Applicable
(see chart) on page 4 and 5
Install the nylon spacers to the mounting points on the
flat panel see figure 3.
NOTE: See chart (if the nylon spacers apply to your
flat panel).
Center mark
Inverted flat panel
Lay the left and right mounting
brackets (stamped arrows facing out).
See figure 4.
Mounting brackets
Bottom of flat
panel
Arrows facing out
- 11 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Match the center of viewing guide with the center
line you marked in step 1.
See figure 5.
C
L
Bottom of flat
panel
Align the
mounting brackets
Mounting bracket
The mounting brackets are designed with a center
of viewing guide on the side of them.
See figure 6.
Bottom of flat
panel
Center of
viewing guide
Center of flat
panel
- 12 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Securing the mounting brackets
DIMPLES
The Griplates™ have M4, M5 M6 and M8 hole
patterns to fit the hardware that your flat panel
requires.
M8
EXAMPLE: If your plasma uses M8 x 20 Phillip
screws. Use the M8 mounting points. See figure 7
M6
Pre install two (2) M6 x 30 (mm) Phillip pan screws to
the bottom of the left and right hand side mounting
brackets. Once the mounting brackets are aligned secure
the Griplate™ to the flat panel.
M5
NOTE: The dimples of the top plates have to be facing
up and the bottom dimples must be facing down.
Use (1) Griplate™ per mounting point. See figure 8.
M4
Phillips screw
driver
DIMPLES
FACING UP
DIMPLES
FACING UP
Bottom of flat
panel
DIMPLES
FACING DOWN
DIMPLES
FACING DOWN
CAUTION: Do not over tighten the mounting
hardware.
NOTE: Secure the two (2) M6 x 30 Phillip pan
screws to the left and right mounting bracket.
- 13 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Finding the wood studs behind the wall structure
Using a (commercially available) wood stud finder,
locate the 16" or 24" stud centers behind the wall.
Once found, make a pencil marking on the center of
the wood studs.
Wood stud finder
(commercially available)
See figure 9.
Mark the wall and
the center of the
wood studs.
NOTE: The wall plates have (3) 16" and (1)
24" mounting slot positions.
(Look at the assembly drawing on page 3)
16"
Wood studs
behind the wall
structure
16"
16"
Center of
viewing port
Mark the
bottom of the
carton template
Carton
template
Align the center viewing port from the carton template to
the center of the wood studs horizontally. Match the
center of viewing port to the center of viewing height
desired and mark a line on the bottom of the carton
template.
Center of
viewing mark
See figure 10.
- 14 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Marking the bottom plate mounting points
Place the upper portion of the bottom wall plate to the
reference line and mark the four (4) lag bolt mounting points
through the wall plate slots on the wall. Level the wall plate
with the reference arrow pointing up to the ceiling.
See figure 11.
Wallplate
16"
Mounting
slots
Woodstuds
Drill gun
Level
Pilot holes
Drill four (4) ¼" pilot holes to the marked
wall.
See figure 12.
16"
- 15 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Securing the bottom wall plate
Level
Level and secure the plate to the wall with
the reference arrow facing up to the ceiling.
Secure the plate using the four (4) 5/16" lag
bolts and flat washers (supplied). See figure
13.
CAUTION: Do not over tighten the lag bolts.
Wall plate
(4) 5/16" x 3" lag bolts
and (4) flat washers
(supplied)
Marked wall
When the bottom wall plate is properly
installed to the wall. Lay the carton template on
top of the wall plate.
Lay the top wall plate on top of the cardboard
template and mark the four (4) lag bolt
mounting points.
See figure 14.
Template
Wall plate
- 16 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Securing the top plate
Drill four (4) ¼" pilot holes to the
marked wall. See figure 15.
Wall marks
Wall plate
- 17 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Level and secure the plate to the wall with
the reference arrow facing up to the ceiling.
Secure the plate using the four (4) 5/16" lag
bolts and flat washers (supplied). See figure 16
CAUTION: Do not over tighten the lag bolts.
NOTE: CHECK THE MOUNT FOR PROPER
TIGHTNESS AND SECURITY.
Power source
area
Wall plates
- 18 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Securing the flat panel to the wall mount
WARNING: AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO
DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL.
Raise the flat panel with the LEFT and RIGHT mounting brackets secured
to the flat panel and insert the top and bottom hooks from each bracket to
the rods from the wall plates. See figure 17.
TOP
BOTTOM
- 19 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Make any lateral shift adjustment and lock it
by tightening the two (2) M6 x 30 (mm)
Phillips screws found on the bottom of the
mounting brackets.
CAUTION: Do not over tighten the M6
screws to the rods.
See figure 18
Lateral shift
M6 x 30 Lateral
shift screw
- 20 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Lateral shift adjustment
Tilt the flat panel and secure the two (2) M6 x 12 (mm)
safety knobs to each of the mounting brackets.
See figure 19.
M6 x 12
Safety knobs
NOTE: To remove the display from the wall simply extend the display to its maximum tilt range, remove the two 6 (mm) safety
knurl knobs push the flat panel back to it’s flat position loosen or remove the two (2) M6 x 30 lateral shift screws and lift the
unit of the wall.
- 21 -
Download from Www.Somanuals.com. All Manuals Search And Download.
NORTH AMERICA
3130 East Miraloma Avenue
Anaheim, CA 92806 USA
USA and Canada –
EUROPE
ASIA
Swallow House,
Yabara 1916-15,
Shilton Industrial Estate,
Shilton, Coventry, England CV79JY
Phone: +44 (0) 2476 614700
Fax: +44 (0) 2476 614710
Misato-machi, Gunma-gun
Gunma-ken 370-3107, Japan
Phone: 81.27.371.6998
Fax: 81.27.371.6308
Phone: 800-368-9700
Fax: 800-832-4888
Other Locations – Phone: 001.714.632.7100; Fax: 001.714.632.1044
©Premier Mounts 2004
- 22 -