OPERATING INSTRUCTIONS LG 39E Multi User Combogard /Swingbolt
Keypad 3035, 3710, 3750 or 3750K with reading contact
Lock 39E
Contact of
the audit trail
LED
3750
3750K
3035
3710
Generally
Each pressing of a key is confirmed by a signal (an acoustic signal and a LED flash). A valid code is
followed by a double signal, an invalid code by a triple signal. After an interval of more than 10-seconds,
the already entered part of the code is deleted and the entire sequence has to be re-entered.
Code entering:
a) Operation with parallel code:
(manager mode)
Enter the seven-digit numeric code–or a word with 7 characters
a double signal is followed.
Manager code: 1234567
b) Operation with dual codes:
(must be programmed)
Six-digit numeric codes or words with six characters.
For opening two valid codes must be entered.
Manager code: 123456 and User ID# 654321
Opening:
Locking:
Combogard: Enter the code and (after double signal) turn the
entry clockwise within 3 seconds unto the hold. The lock is open
and the entry is rotated.
Swingbolt: Enter the code and (after double signal) turn the
handle within 3 seconds into the OPEN position.
If the lock is not opened within 3 seconds, it is automatically
locked again.
Combogard: Turn the entry counter-clockwise unto the hold.
The lock is automatically closed and the entry stands straight.
(Check this by trying to turn the entry back again)
Swingbolt: Turn the handle into the CLOSE position.
The lock is automatically locked; check this by trying to turn the
handle into “OPEN” position.
I M P O R T A N T
Check the lock to be locked.
Wrong try penalty:
After four invalid codes, the entry is blocked for about 5
minutes. During this period, the lock signals at 10-second
intervals. After this time penalty, the entry of every second
invalid code initiates a new 5 minutes delay period.
The key pressing is refused with a triple signal.
Change of code:
(always with open door)
The user can change its code anytime.
Enter the code and keep pressed the last number until second
double signal (LED is on), press the “0” and enter the new code
(double signal), enter the new code once more for confirmation
(double signal).
The new code is now valid. If mistakes are made while
changing the code or if an interval occurs of more than 10
seconds, the old code remains valid and the entire sequence
has to be re-entered.
Test the new code several times by open door!
LG 39E Combogard EN
Revise: 1
Datum: 16-02-05
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Kantooradres:
Postadres:
Vlijtstraat 40
Postbus 127
NL-7005 BN Doetinchem
H.R. te Arnhem nr: 09087869
BTW nr: NL 8038.72.987.B01
NL-7000 AC
Tel: (+31) 314 376 876
Fax: (+31) 314 376 878
LA GARD Locks BV
E-mail: [email protected]
Manual programming
Factory Mode
(Pre-Setup-mode)
LG 39E Multi User
The lock maybe mounted in the factory mode. It opens when
pressing key “1” and it sends a silent alarm signal.
The advantage is that there is only 1 version storage and an
easy use during mounting.
Exit the Factory-Mode
Keep pressed the key “0” until the double signal (4-5
seconds). Now the manager code is 555555.
Code length and program selection The code length and program selection are made with the
(6-9 digit code length is possible)
function “8” in a group of 2 digits. The first digit is the code
length and the second one is the program number.
Program 0 = Manager mode (operation with parallel code)
Program 1 = Manager mode with delay override
Program 2 = Operation with two codes
Program 3 = Two code operation with delay override
Program 4 = Manager mode with alarm
Program 5 = Manager with alarm and with delay override
Program 6 = Two code operation with alarm
Program 7 = Two code operation, alarm and delay override
Programming
(function 8)
Enter the manager code “555555” and keep pressed the
last number until the double signal is repeated (LED is on)
and enter “8”. Enter the group of 2-digits (code length and
program number) double signal and repeat the group for
confirmation (double signal).
In case of the 7-digit codes the manager code is 7x “5”.
Install (Enable) user
(function 1)
Enter manager-code and keep last digit pushed until LED
stays on. Press „1“ (double signal) and enter user-ID Nr. f.i.
„1“ (double signal). Enter user code (double signal) and to
confirm, enter the code again. Double signal and LED
extinguished.
In case a new code is not accepted (3-time-signal), this code
is too similar to an already existing code. Select new code.
NOTE: Users who are not installed in this stage will be
blocked after changing the manager code!
Program “freeze”
After changing the manager code the program is „frozen“ and
the program settings can only be changed after a reset to
Factory Mode.
Reset to Factory Mode
In case the manger code is lost or the setting of the lock has
to be changed, a reset can be executed by means of the
RESET-BOX (PN#6066). Unplug battery from the lock or
entry.
Push the "0" button for ca. 3 minutes (or leave it for
10minuts powerless) and plug the RESET-BOX in the BAT-
connection of the lock. Wait until a longer signal. (0,5 sec)
The Reset-Box requires a connected 9V-DURACELL
ALKALINE-battery.
The lock is in FACTORY MODE. Disconnect Reset-Box and
plug battery back again. Lock opens with “1”.
Safety notice: Do not assign code to the users of no use for the time being.
Remove the codes. (Function 3 and user number)
LG 39E Combogard EN