Multi Type Air Conditioner
OWNER'S MANUAL
MODELS:
IMPORTANT
6710 YS
Please read through this manual. It contains valuable
6720 YS
information about your air conditioner. This manual may
help save time and money by explaining proper product
maintenance and preventing improper use.
PRECAUTIONS
Pay close attention to precautions in order to prevent
potential hazards and damage from misuse or improper
installation. LG is not responsible for any damages caused
by misuse of the product.
Prior to installation, this air-conditioning
unit must be submitted for approval by the
utility service which provides electricity
(EN 61000-3 Norm.)
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety
Precautions
Precautions
To prevent injury and property damage, follow these instructions.
Incorrect operation due to ignoring instructions will cause harm or damage, the seriousness of which is
indicated by the following symbols.
This symbol shows the possibility of death or serious injury.
WARNING
This symbol indicates the possibility of injury or damage to property.
CAUTION
Never Do This
Always Do This
■ The following items are classified by these symblos.
WARNING
WARNING
Plug in the power plug
properly.
Do not operate or stop the
unit by inserting or pulling
out the power plug.
Do not damage or use an
unspecified power cord.
• Otherwise, it will cause electric
shock or fire due to heat
generation or electric shock.
• It will cause electric shock or fire
due to heat generation.
• It will cause electric shock or fire.
•
In the supply cord is damaged, it mut be
replaced by the manufacturer or its
service agent or a similarly quallfied
person in order to avoid a hazard.
Do not modify power cord
length or share the outlet
with other appliances.
Do not operate with wet
hands or in damp
environment.
Do not direct airflow at
room occupants only.
• It will cause electric shock or fire
due to heat generation.
• It may cause electric shock.
• This could damage your health.
Always perform grounding
work.
Do not allow water to run
into electric parts.
Always install air leakage
breaker and a dedicated
switching board.
•
No grounding may cause electric
shock (See Installation Manual).
• It may cause failure of machine
or electric shock.
• No installation may cause fire
and electric shock accident.
Unplug the unit if strange
sounds, smell, or smoke
comes from it.
Do not use the socket if it is
loose or damaged.
Do not open the entrance
during operation.
• It may cause fire and electric
shock accident.
• It may cause fire and electric
shock.
• It may cause electric shock.
Keep firearms away.
Do not use the power cord close to
the heating tools.
Do not use the power cord near
flammable gas or combustibles, such
as gasoline, benzene, thinner, etc.
• It may cause fire.
• It may cause fire and electric
shock.
• It may cause an explosion or fire.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION
CAUTION
• Contact the authorized Service technician for repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young children or infirm persons without
supervision.
• Young children should be supervised to ensure that they do not play with the air conditioner.
CAUTION
CAUTION
When the air filter is to be
removed, do not touch the
metal parts of the indoor unit.
Do not clean the air
conditioner with water.
Ventilate well when used
together with a stove, etc.
• It may cause an injury.
• Water may enter the unit and
degrade the insulation. It may
cause an electric shock.
• An oxygen shortage may
occur.
• Should be disconnected from
supply
When the unit is to be
cleaned, switch off, and
turn off the circuit breaker.
Do not put a pet or house
plant where it will be
exposed to direct air flow.
Do not leave on installation
stand which is damaged.
• Since the fan rotates at high
speed during operation, it may
cause an injury.
• This could injure the pet or
plant.
• The unit may drop or fall down
and cause an injury.
Do not apply an insecticide
or flammable spray.
Do not put a stove, etc.
where is exposed to direct
air flow.
Do not step on the
indoor/outdoor unit and
do not put anything on it.
• It may cause a fire or
deformation of the cabinet.
•
It may affect combustion.
• It may cause an injury through
dropping or falling down.
Do not insert hands
through vanes when the air
conditioner is operationg
When the unit is not going
to be used for a long time,
turn off the circuit breaker.
Do not step onto an unstable
bench when cleaning and/or
maintaining the unit.
• It will cause an injury by the
rotating blower.
• If not, dirt may collect and
cause a fire.
• It may cause an injury, etc. by
falling down.
Do not use for special purposes.
Do not operate for a long time in high
humidity, e.g. leaving a door or window
open.
• Do not use this air conditioner to preserve
precision devices, food, animal, plants, and
art objects.
• In the cooling mode, if it is operated in a
room with high humidity (80%RH or more) for
a long time, water condensed in the air
conditioner may drop and may wet and spoil
furniture, etc.
It may cause deterioration of quality, etc.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating
Instructions
Preparation before operation
How to Insert the Batteries
Remove the battery cover by pulling it according to the arrow
direction.
1
Insert new batteries making sure that the (+) and (-) of battery are
installed correctly.
2
3
Reattach the cover by sliding it back into position.
NOTES:
• Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries.
Storage and Tips For Using the Remote Control
• The remote control may be stored mounted on a
wall.
• To operate the room air conditioner, aim the
remote control at the signal receptor.
Signal Receptor
Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)
Operation Indication Lamps
On/Off
: Lights up during the system operation.
: Lights up during Sleep Mode Auto operation.
: Lights up during Timer operation.
Sleep Mode
Timer
Defrost Mode : Lights up during Defrost Mode or Hot
Start operation (Heat pump model only)
Signal
OUT
DOOR
: Lights up during outdoor unit operation.
(Cooling model only)
receptor
Operation indication lamps
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating
About the remote control on the system
Instructions
The remote control transmits the signals to the system.
Features of the Remote Control
START/STOP BUTTON
Operation starts when this button is pressed and
stops when the button is pressed again.
1
Signal transmitter
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
2
3
4
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps low, medium,
high, or CHAOS.
5
4
6
JET COOL
5
Used to start or stop the speed cooling. (Speed
cooling operates super high fan speed in cooling
mode.)
1
3
ON
OFF
CHAOS SWING BUTTON
Used to stop or start louver movement and set the
desired up/down airflow direction.
7
8
9
2
10
11
12
13
6
7
SET
CANCEL
PLASMA
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping
operation.
14
TIME SETTING BUTTONS
Used to adjust the time. (See page 13)
8
9
TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is
obtained and to cancel the Timer operation.
(See page 13)
Flip-up door
(opened)
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.(See page 13)
10
11
Operation Mode
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or
heating (turns indoor fan on/off). (See page 14)
Cooling Operation
Auto Operation
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
12
13
PLASMA(OPTIONAL)
Healthy Dehumidification Operation
Used to start or stop the plasma-purification function.
(See page 12)
Heating Operation
RESET BUTTON
14
Used prior to resetting time or after replacing
batteries.
•
Cooling Model( ), Heat Pump Model(
)
6
Download from Www.Somanuals.com. All Manuals Search And Download.
How to use the Operation Mode
Selection button
Operating
Instructions
Cooling Operation
Press the Start/Stop button.
The unit will respond with a beep.
1
2
Open the door on the remote control. To select Cooling
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is shifted
in the direction of the arrow.
Cooling
Auto
Healthy
Dehumidification
Heating
(Heat pump model only)
Close the door on the remote control. Set the temperature
lower than the room temperature. The temperature can be set
within a range of 18°C~30°C in 1°C increments.
3
4
To raise the temperature
To lower the temperature
Set the fan speed again with the door of the
remote control still closed. You can select the
fan speed in four steps-low, medium, high, or
CHAOS. Each time the button is pressed, the
fan speed mode is shifted.
Natural wind by the CHAOS logic
■ For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS
mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according
to the CHAOS logic.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Auto Operation
Press the Start/Stop button.
1
2
The unit will respond with a beep.
Open the door on the remote control. To select Auto
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
Cooling
Auto
Healthy
Dehumidification
Heating
(Heat pump model only)
The temperature and fan speed are automatically set by the
electronic controls based on the actual room temperature. If
you want to change the set temperature, close the door on
the remote control and press the Room Temperature Setting
buttons. The cooler or warmer you feel, the more times (up to
two times) you should press the button. The set temperature
will then be changed automatically.
3
To raise the temperature
To lower the temperature
DURING AUTO OPERATION:
■ You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule.
■ If the system is not operating as desired, manually switch to another mode. The system will not
automatically switch from the cooling mode to the heating mode, or from heating to cooling, it must be
done by manually resetting.
■ During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and
down automatically. If you want to stop auto-swing, press the chaos swing button again.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Healthy Dehumidification Operation
Press the Start/Stop button.
The unit will respond with a beep.
1
Open the door on the remote control. To select Healthy
Dehumidification Operation, press the Operation Mode
Selection button.
Each time the button is pressed, the operation mode is shifted
in the direction of the arrow.
2
3
Cooling
Auto
Healthy
Heating
Dehumidification (Heat pump model only)
Set the fan speed again with the door of the
remote control still closed. You can select
the fan speed in four steps-low, medium,
high, or CHAOS. Each time the button is
pressed, the fan speed mode is shifted.
NATURAL WIND BY THE CHAOS LOGIC
■ For more fresh feeling than other fan speed, press the Indoor Fan
Speed Selector and set to CHAOS mode. In this mode, the wind
blows like natural breeze by automatically changing fan speed
according to the CHAOS logic.
DURING HEALTHY DEHUMIDIFICATION OPERATION:
■ If you select the dehumidification mode on the operation selection button, the A/C starts to run the
dehumidification function, automatically setting the room temp. and airflow volume to the best
condition for dehumidification based on the sensed current room temp.
In this case, however, the setting temp. is not displayed in the remote control and you are not able to
control the room temp. either.
■ During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status and makes the room condition
healthy and comfortable even in the high humidity season.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Heating Operation(Heat pump model only)
Press the Start/Stop button.
The unit will respond with a beep.
1
Open the door on the remote control. To select Heating
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is shifted in
the direction of the arrow.
2
Cooling
Auto
Healthy
Heating
Dehumidification (Heat pump model only)
Close the door on the remote control.
Set the temperature higher than the room temperature.
The temperature can be set within a range of 16°C~30°C in 1°C
increments.
3
4
To raise the temperature
To lower the temperature
Set the fan speed again with the door of the
remote control still closed. You can select
the fan speed in four steps–low, medium,
high, or CHAOS. Each time the button is
pressed, the fan speed mode is shifted.
NATURAL WIND BY THE CHAOS LOGIC
■ For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to
CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan
speed according to the CHAOS logic.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Jet Cool Operation
Press the Start/Stop button.
The unit will respond with a beep.
1
Press the Jet Cool button to operate the
speed cooling mode and the unit will operate
in super high fan speed on cooling mode for
30 minutes.
2
3
To cancel the Jet Cool mode, press the Jet Cool button
again or the fan speed button or the room temperature setting
button and the unit will operate in high fan speed on cooling
mode.
or
or
NOTE:
■ During the JET COOL function at any moment, the A/C starts to blow the cool air at
extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is
especially used to cool the room temp. in the shortest time in a hot summer.
In heat pump mode or neuro fuzzy mode however, the JET COOL function is not available.
■ In order to return to the normal cooling mode from the JET COOL mode, you just press
either the operation mode selection button, airflow volume selection or temp. setting
button or the JET COOL button again.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
PLASMA Purification Operation(Optional)
Press the Start/Stop button. The unit
will respond with a beep.
1
Open the door on the remote control.
Press the PLASMA air purifying
operation ON/OFF button.
Operation will start when the button is
2
PLASMA
pressed and stop when the button is
pressed again.
Set the fan speed again with door of the remote control
closed. You can select the fan speed in four steps-low,
medium, high or CHAOS. Each time the
button is pressed, the fan speed mode
is shifted.
3
■ Air purifying operation (PLASMA) can be
with cooling, Heating or any other operations.
PLASMA Air Purifying Operation only
If you press the only PLASMA button, only
PLASMA air purifying operates.
Then, fan speed is low. You can select the fan
speed in four steps-low, medium, high or
CHAOS.
Each time the button (
speed mode is shifed.
) is pressed, the fan
PLASMA
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating
Additional features
Instructions
Sleep Mode
Press the Sleep Mode Auto button to set the time
you want the unit to turn off automatically.
To cancel the Sleep Mode, press the sleep
Mode Auto button several times until the star
) disappears from the operation display.
1
2
(
The Timer is programmed in one-hour
increments by pressing the Sleep Mode Auto
button 1 to 7 times.
The sleep mode is available for 1 to 7 times. To
alter the time period in steps of 1 hour, press the
Sleep Mode Button while aiming at air
conditioner.
No t e : The Sleep Mode will be operated at
low fan speed (cooling) or medium fan
speed (heat pump only) for quiet sleeping.
IN COOLING MODE: The temperature will
automatically rise by 1°C over the next 30
minutes and by 2°C in 1 hour for comfortable
sleeping.
Make sure the Sleep Mode Auto LED lights up.
3
Setting the Time
Time can be set only when you have pressed
the Reset button. If you have just replaced the
batteries, the Reset button should be pressed
to reset the time.
Press the Time Setting buttons until the
desired time is set.
2
3
1
SET
Press the Start/Stop button.
Press the Timer SET button.
No t e : Check the indicator
for A.M. and P.M.
Delay Start/Pre-Set Stop
SET
Make sure the time is set correctly on the
remote control display.
Press the selected on/off setting by
4
1
pressing the Timer SET button while
aiming the remote control at the signal
receptor.
ON
OFF
Press the ON/OFF Timer
buttons to turn Timer on or off.
2
3
To cancel the setting the timer.
Press the Timer Cancel button while
CANCEL
aiming remote control at the signal
receptor.
(The timer lamp on the air conditioner and
the display will go out.)
Press the Time Setting
buttons until the desired
time is set.
NOTE: Select one of the following four types of operation.
with the unit running
Delay OFF Timer
Delay ON Timer
Delay OFFand ON Timer
Delay ONand OFF Timer
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Vertical Airflow Direction Control
The up/down airflow (Vertical Airflow) can be adjusted
by using the remote control.
No t e :
■ If you press the CHAOS swing button, the horizontal
airflow direction is changed automatically based on
the CHAOS algorithm to distribute the air in the room
evenly and at the same time to make the human body
feel most comfortable, as if enjoying a natural breeze.
■ Always use the remote control to adjust the up/down
airflow direction. Manually moving the vertical airflow
direction louver by hand could damage the air
conditioner.
■ When the unit is shut off, the up/down airflow direction
louver will close the air outlet vent of the system.
To adjust left/right(Horizontal Airflow) direction
Caution : Ensure unit is turned off before adjusting the
horizontal airflow direction control. Carefully
open vertical louver to allow access to the
horizontal airflow direction.
Press the Start/Stop button to start the unit.
Open the door on the remote control.
Adjust the left/right airflow direction by hand.
Press Chaos Swing button and the louvers will swing
up and down. Press the Chaos Swing button again to
set the vertical louver at the desired airflow direction.
Air Circulation Mode
Circulates the room air without cooling or heating.
Press the Start/Stop button. the unit will respond with a beep.
1
2
Open the door on the remote control. Press the Air Circulation button. Close the door on the remote
control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low
to CHAOS and back to low again.
CHAOS Air
Fan speed is on low. Fan speed is on medium. Fan speed is on high.
No t e :
■ CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically
changed from high to low or vice versa, depending on the ambient temperature.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Slide Switch Operation
FORCED OPERATION
Slide Switch
Operation procedures when the remote control can't be
used.
Open the front panel upward and move the Slide
Switch to the Forced Operation position.
FORCED
OPERATION
Slide
Switch
AUTO
RESTART
REMOTE
CONTROL
If you want to stop operation, move the Slide Switch to
the Auto Restart or the Remote Control position.
In case the power comes on again after power failure
on the Forced Operation position, the operating
conditions are automatically set as follows:
During Forced Operation, the initial mode continues.
Open the front
panel upward
Heat pump Model
21°C ≤ Room Temp. < 24°C
Healthy Dehumidification
Healthy Dehumidification Rule
23°C
Cooling Model
Room Temp. ≥ 24°C
Cooling
Room Temp. < 21°C
Heating
Operating mode
Indoor FAN Speed
Setting Temperature
Cooling
High
High
High
22°C
22°C
24°C
Auto restart
Slide Switch
In case the power comes on again after a power failure,
Auto Restarting Operation is the function to operate
procedures automatically to the previous operating
conditions.
If you want to use this operation, Open the front panel
upward and move the slide switch to the Auto Restart
position.
FORCED
OPERATION
Slide
Switch
AUTO
RESTART
REMOTE
CONTROL
Open the front
panel upward
If you do not want to use this operation, move the Slide
Switch to the Remote Control position.
When you are out for a while, put the
Slide Switch on the Remote Control.
HELPFUL INFORMATION
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the
value when the fan speed is set to high, and the capacity will
be lower at low or medium fan speed.
High fan speed is recommended when you wish to cool the
room quickly.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Care and maintenance
of the air conditioner
Care and maintenance of the air conditioner
CAUTION: Before performing any maintenance, turn off the main power to the system.
Indoor Unit
Grille, Case, and Remote Control
■ Turn the system off before cleaning. To
clean, wipe with a soft, dry cloth. Do not
use bleach or abrasives.
■
Never use any of the followings:
• Water hotter than 40°C
Could cause deformation and/or
discoloration.
NOTE:
Supply power must be disconnected before
cleaning the indoor unit.
• Volatile substances
Could damage the surfaces of the air
conditioner.
P
o
w
d
e
r
G
a
e
l
i
n
s
o
Air filters
Air outlet vent
Air inlet vent
(behind front panel)
Vertical louver
Horizontal louver
Lift the front access panel and pull the filter tab
slightly forward to remove the filter.
1
AIR FILTERS
Clean the filter with a vacuum or warm, soapy
water.
• If dirt is conspicuous, wash with a solution
of detergent in lukewarm water.
• If hot water (40°C or more) is used, it may
be deformed.
The air filters behind the front grille should be
checked and cleaned once every 2 weeks or more
often if neccessary.
2
3
4
After washing with water, dry well in the shade.
Re-install the air filter.
After removing the air filters, pull slightly
forward to remove the PLASMA filter.
PLASMA FILTER, DEODORIZER
FILTER(OPTIONAL)
The PLASMA filter behind the air filters should be
checked and cleaned once in every 3 months or more
often if necessary.
1
2
3
Dip the PLASMA filter into the water mixed with
neutral detergent, for 20~30 minutes.
Dry the PLASMA filter in the shade for a day
(Especially, the humidity must be removed
perfectly on this parts).
Note the cuts of electric discharge lines.
4
5
Re-install the PLASMA filter to the original
position.
DEODORIZER Filter
PLASMA Filter
After removing the air filters, pull slightly
forward to remove the DEODORIZER filter.
1
2
3
Dry in the sunlight for two hours.
Don’t touch this PLASMA Filter within 10
seconds after opening the inlet grille, it may
cause an electric shock.
Re-install the DEODORIZER filter to the original
position.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacement of Purifying Filter(Option)
• Recomended use period : About 2 years
Open front panel and remove air
filters.
Remove air purifying filters.
Insert new air purifying filters.
1
2
3
2
Air filter
3
Reinsert air filters and close front
panel.
4
Air purifying filter
Outdoor Unit
The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or
soot, the heat exchanger and panel vents may be professionally steam cleaned.
NOTE:
Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.
Piping
Drain Hose
Air outlet
vents
17
Download from Www.Somanuals.com. All Manuals Search And Download.
When the air conditioner is not going to be used for a long time.
When air conditioner is not going to be
used for a long time.
When the air conditioner is to be used again.
Operate the air conditioner on Air circulation
mode (Refer to page 14) for 2 to 3 hours.
Clean the air filter and install it in the indoor
unit.
(Refer to page 16 for cleaning filters.)
1
1
2
• This will dry out the internal mechanisms.
Turn off the circuit breaker, and disconnect
the plug.
CAUTION
CAUTION
Turn off the circuit breaker when the air
conditioner is not going to be used for a long time.
2
Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
Dirt may collect and may cause a fire.
Remove the batteries from the remote
control.
3
Operation Tips
Do not overcool the room.
Keep blinds or curtains
closed.
Keep the room temperature
uniform.
This is not good for the health
and wastes electricity.
Do not let direct sunshine enter
the room when the air
conditioner is in operation.
Adjust the vertical and
horizontal airflow direction to
ensure a uniform temperature in
the room.
Make sure that the doors
and windows are shut tight.
Ventilate the room
occasionally.
Clean the air filter regularly.
Since windows are kept closed,
it is a good idea to open them
and ventilate the room now and
then.
Avoid opening doors and
windows as much as possible
to keep the cool air in the room.
Blockages in the air filter reduce
the airflow and lower cooling
and dehumidifying effects.
Clean at least once every two
weeks.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting Tips!
Save time and money!
Before you call for service...
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or service center.
Case
Explanation
See page
13
The air conditioner does not
operate.
• Have you made a mistake in timer operation?
• Has the fuse blown or has the circuit breaker
been tripped?
-
-
The room has a peculiar
odor.
• Check that this is not a damp smell exuded by
the walls, carpet, furniture, or cloth items in the
room.
It seems that condensation
is leaking from the air
conditioner.
• Condensation occurs when the airflow from
the air conditioner cools the warm room air.
-
-
Air conditioner does not
operate for about 3 minutes
when restarted.
• This is the protector of the mechanism.
• Wait about three minutes and operation will
begin.
Does not cool or heat
effectively.
• Is the air filter dirty? See air filter cleaning
instructions.
16
• Has the temperature been set incorrectly?
• Are the indoor unit's air inlet or outlet vents
obstructed?
7, 10
-
The air conditioner
operation is noisy.
• For a noise that sounds like water flowing.
-This is the sound of freon flowing inside the
air conditioner unit.
• For a noise that sounds like the compressed
air releasing into atmosphere.
-
-This is the sound of the dehumidifying water
being processed inside the air conditioning
unit.
Remote control display is
faint, or no display at all.
• Are the batteries depleted?
• Are the batteries inserted in the opposite (+)
and (-) directions?
5
Crack sound is heard.
• This sound is generated by the
expansion/constriction of the front panel, etc.
due to changes of temperature.
-
NOTE
WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT.
The indoor side is not water resistant and should not be exposed to excess water.
19