OWNER’S MANUAL
GROOVE 600™
BASS AMPLIFIER
Congratulations on the purchase of your new Kustom amplifier! Your new GROOVE
600™ offers unsurpassed sound quality and performance characteristics. Inside this
manual you’ll find detailed information regarding the amplifier’s features. We wish you
many years of enjoyment with your Kustom GROOVE 600™.
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANTES INSTRUCTIONS DE SECURITE
FRENCH
1. Lire avec attention toutes les recommandations et précautions
d'emploi avant d'utiliser ce produit.
Danger
L‘exposition a des niveaux eleves de bruit peut provoquer
une perte permanente de l’audition, Chaque organisme
humain reagit differemment quant a la perte de l’audition,
mais quasiment tout le monde subit une diminution de
I’acuite auditive lors d’une exposition suffisamment
longue au bruit intense. Les autorites competentes en
reglementation de bruit ont defini les expositions tolerees
aux niveaux de bruits:
2. Toutes les recommandations et précautions d'emploi doivent
être conservées afin de pouvoir s'y reporter si nécessaire.
3. Lire et comprendre tous les avertissements énumérés dans les
précautions d'emploi.
4. Suivre toutes les précautions d'emploi pour utiliser ce produit.
5. Ce produit ne doit pas être utilisé près d'eau, comme par
exemple baignoires, éviers, piscine, sous-sol humides ... Etc.
6. Utiliser exclusivement un chiffon sec pour nettoyer ce produit.
7. Ne bloquér aucune ouverture de ventilation. Ne pas placer le
produit tout contre un mur ou dans une enceinte fernée, cela
gênerait le flux d'air nécessaire au refroidissement.
DURE EN HEURES PAR JOUR
8
6
4
3
2
1
8. Ne pas placer le produit près de toute source de chaeur telle
que radiateurs, arrivées d'air chaud, fourneaux ou autres
appareils générant de la chaleur (incluant les amplificateurs
producteurs de chaleur) .
INIVEAU SONORE CONTINU EN dB
90 93 95 97 100 103
Selon les autorites, toute exposition dans les limites
citees ci-dessus,peuvent provoquer certaines pertes
d’audition. Des bouchons ou protections dans l’appareil
auditif ou sur l’oreille doivent etre portes lors de
l’utilisation de ce systeme d’amplification afin de prevenir
le risque de perte permanente de l’audition, Dans le cas
d’expositions superieures aux limites precitees il est
recommande, afin de se premunir contre les expositions
aux pressions acoustiques eIevees potentielIement
dangeureuses, aux personnes exposees aux
9. Ne pas négliger la sécurité que procure un branchement
polarisé ou avec raccordement à la terre, Un branchement
polarisé comprend deux fiches dont l'une est plus large que
l'autre. Un branchement à la terre comprend deux fiches plus
une troisième reliée à la terre. Si la fiche secteur fournie ne
s'insert pas dans votre prise de courant. consulter un
'électricien afin de remplacer votre prise obsolète.
10. Protéger le cordon d'alimentation de tout écrasement ou
pincement, particulièrement au niveau des fiches, des
réceptacles utilisés et à l'endroit de sortie de l'appareil. Ne pas
casser la fiche de terre du cordon d'alimentation.
11. Utiliser uniquement les accessoires spécifiés par le
constructeur.
equipements capables de delivrer de telles puissances,
tels ce systeme d’amplification en fonctionnement, de
proteger l’appareil auditif.
12. Utiliser uniquement avec le chariot de
transport, le support, le trépied, la
console ou la table spécifiés par le
constructeur ou vendus avec l'appareil.
Lors de l'utilisation d'un chariot, bouger
ATTENTION
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR.
S3125A
avec précaution l'ensemble chariotlappareil
afin d'éviter les dommages d'un renversement.
ATTENTION: AFIN DE LlMlTER LE RISQUE DE CHOC ELECTRIQUE,
NE PAS ENLEVER LE CHASSIS. NE CONTIENT PAS DE
PIECES POUVANT ETRE REPAREE PAR L’UTILISATEUR.
CONFIER LE SERVICE APRES-VENTE AUX
13. Débrancher cet appareil lors d'orages ou s'il n'est pas utilisé
pendant une longue période.
REPARATEURS AGREES.
14. Des précautions doivent être prises afin qu'aucun objet ne
tombe et qu'aucun liquide ne se répande à l'intérieur de
l'appareil par les orifics de ventilation ou n'importe quelle autre
ouverture.
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE
DE VOLTAGE DANGEREUX NON-ISOLE A L'INTERIEUR DE CE PRODUIT
QUI PEUT ETRE DE PUISSANCE SUFFISAMMENT IMPORTANTE POUR
PROVOQUER UN CHOC ELECTRIQUE AUX PERSONNES.
15. Pour toutes interventions techniques s'adresser à un
technicien qualifié.L'intervention technique est nécessaire
lorsque l'appareil a été endommagé de n'importe quelle façon,
comme par exemple si le cordon secteur ou sa fiche sont
détériorés,si du liquide a coulé ou si des objets sont tombés à
l'intérieur de l'apparei1,si l'appareil a été exposé à la pluie ou à
l'humidité, s'il ne fonctionne pas normalement ou s'il est tombé.
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE
D'INSTRUCTIONS D'UTILISATION ET DE MAINTENANCE DANS LES
DOCUMENTS FOURNIS AVEC CE PRODUIT.
16. ATTENTI0N:Pour réduire le risque d'incendie ou de choc
electrique ne pas exposer l'appareil à la pluie ou à l'humidité.
AFIN DE REDUIRE LES RISQUÉ D'INCENDIE ET DE DECHARGE
ELECTRIQUE, NE PAS EXPOSER CET APPAREIL A LA PLUIE OU A
L'HUMIDITE.
17. La prise Mains, au coupler, est utilisé pour la source
d'alimentation êlectrique. Il est conseillê de garder cette prise
facilement accessible.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Contents
These items are included with your GROOVE 600™ amplifier.
Be sure to contact your dealer if any items are missing.
9-BAND ACTIVE EQ
FLAT
FLAT
FLAT
-12 dB
NORM
-6dB
+6dB
-6dB
+6dB
-6dB
+6dB
-12dB
+12dB -12dB
+12dB -12dB
+12dB
GROOVE 600™ Amplifier
OWNER'S MANUAL
Warranty Card
Owners Manual
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Setup
After reviewing this Quick Setup page, feel free to experiment with the
controls and create your own unique sound.
1
2
Set tone controls flat and Master Volume Control down.
9-BAND ACTIVE EQ
FLAT
FLAT
FLAT
-12 dB
NORM
-6dB
+6dB
-6dB
+6dB
-6dB
+6dB
-12dB
+12dB -12dB
+12dB -12dB
+12dB
Connect input, AC power cord, footswitch cable, and speaker cable. If using an
active bass, toggle the NORM/-12 dB Switch to -12 dB. If the Red Clip Indicator
lights while playing, toggle the NORM/-12 dB Switch to -12 dB.
9-BAND ACTIVE EQ
FLAT
FLAT
FLAT
-12 dB
NORM
-6dB
+6dB
-6dB
+6dB
-6dB
+6dB
-12dB
+12dB -12dB
+12dB -12dB
+12dB
TUNER OUT
GROUND
LIFT
PRE EQ
MODEL: GROOVE 600™
POST EQ
BREAKER
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DIRECT OUTPUT
EFFECTS LOOP
ATTENTION
RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR
2001124
SERIAL NUMBER
CAUTION
CHASSIS SURFACE HOT
DESIGNED IN USA
MADE IN CHINA
ATTENTION
SUPERFICE DE CHASSIS CHAUDE
SEND
RETURN
FOOTSWITCH
SPEAKER OUTPUT
Insert and twist
clockwise to lock.
Speaker
Cabinet
(Footswitch optional)
3
Turn on the Power Switch. Play an open string and adjust the Gain Control until
the Green Signal Indicator lights regularly. Turn up Master Volume Control
slowly to desired level, and start playing.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Front Panel
9-BAND ACTIVE EQ
FLAT
FLAT
FLAT
+6dB
-6dB
+6dB
-6dB
+6dB
-6dB
-12dB
+12dB -12dB
+12dB -12dB
+12dB
a
Input Jack:
h
Bass Control:
Controls the amount of low frequency in the signal.
This control is centered at 65 Hz.
This is a 1/4" 2-conductor input jack for plugging
in your instrument using a shielded instrument
cable. It is intended for bass guitar but will accept
other instruments and line level signals as well.
i
Mid Control:
Controls the amount of midrange frequency in the
signal. This control is centered at 500 Hz.
b
NORM/-12 dB Switch
Set this switch to -12 dB when using an active
bass guitar or line level signal. Setting to -12 dB
will lower the input gain by 12 dB.
j
High Control:
Controls the amount of high frequency in the signal.
This control is centered at 3 kHz.
c
Gain Control:
k
Graphic Equalizer Section:
Controls the amount of input to the preamp.
Adjust so SIG indicator illuminates when notes
are played.
This 9-band graphic equalizer is used to adjust the
sound to the room acoustics. It may also be used to
finely adjust sound to taste.
d
Clip Indicator:
l
Master Volume Control:
Indicates when the input signal has reached
maximum level. If indicator illuminates when
notes are played , set NORM/-12 dB switch to
-12 dB and/or turn down GAIN control.
Controls the overall output of the amplifier. Use in
conjunction with the GAIN control to obtain
desired speaker output.
m
Power Switch:
e
Signal Indicator:
Turns AC power on and off. Note: When power is
first applied, there is a slight delay before sound is
heard through the speakers.
Indicates when sufficient signal is applied to the
preamp. Adjust GAIN control so indicator
illuminates when notes are played.
n
Solo Indicator:
This blue LED is lit when the SOLO mode has
been activated.
f
Mute Indicator:
This red LED will blink indicating all outputs are
muted except for the TUNER OUT (rear panel
#23). Muting can be done by either depressing the
MUTE ON/OFF switch on the front panel or by
pressing MUTE on the footswitch.
o
Solo On/Off Switch: This switch when
depressed, activates SOLO mode. When active, the
signal to the power amp will be boosted by 6dB.
p
Power Jewel:
Indicates when AC power is applied to the
amplifier.
g
Mute On/Off Switch:
When this switch is depressed, all outputs are
muted except for the TUNER OUT (rear panel
#23). Note: Using footswitch overrides this
switch.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Rear Panel
TUNER OUT
GROUND
LIFT
PRE EQ
MODEL: GROOVE 600™
POST EQ
BREAKER
LINE LEVEL
DIRECT OUTPUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION
RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR
EFFECTS LOOP
SERIAL NUMBER
CAUTION
CHASSIS SURFACE HOT
DESIGNED IN USA
MADE IN CHINA
ATTENTION
SUPERFICE DE CHASSIS CHAUDE
SEND
RETURN
FOOTSWITCH
SPEAKER OUTPUT
25
q
Circuit Breaker:
u
Direct Output Jack:
This circuit breaker will trip when too much
current is applied to the amplifier. To reset: Turn
off POWER switch, allow to cool for a few
minutes, then press circuit breaker button, and
turn the POWER switch on. Note: If the Circuit
Breaker trips repeatedly when AC power is
applied, take the amplifier to an authorized service
center for repair.
This is a line level output used to connect the
amplifier to another device, such as a mixer or
recorder.
v
Pre EQ/Post EQ Switch:
When set to Pre EQ, the DIRECT OUTPUT signal
will be unaltered by the EQ sections of the preamp.
When set to Post EQ, the DIRECT OUTPUT
signal will reflect the entire sound (including EQ
settings) of the preamp. Note: The MASTER
volume Control (front panel #12) and SOLO
ON/OFF switch (front panel #15) have no effect on
the DIRECT OUTPUT signal.
r
Power Cord:
This supplies AC power to the amplifier. If the
cord becomes damaged, take the amplifier to an
authorized service center for repair.
s
Speaker Outputs:
w
Tuner Out Jack:
Use this jack to connect to a tuner or other line level
device. This jack is always active and is a pre-gain
output.
Use these jacks to connect the amplifier to
speaker cabinets using heavy duty Speakond
speaker cables. These jacks are connected
together internally. See Amplifier Loading
Chart (Page 8) for speaker cabinet loading
information. Note: To prevent overheating and
possible loss of signal, do not connect a load
lower than 2 ohms. Be sure power is off before
making any speaker connections. To connect a
cable: Align tab on speaker cable connector slot.
Insert and twist one quarter turn clockwise to
lock. To remove a cable: Pull back release button
on cable connector, twist connecter counter
clockwise one quarter turn, and pull out connecter.
x
Effects Send Jack:
Use this jack to connect to the input of an external
effects processor. This jack can also be used as a
preamp out.
y
Effects Return Jack:
Use this jack to connect to the output of an external
effects processor. This jack can also be used as a
power amp in. The preamp output signal is
disconnected from the power amp when using this
jack.
z
Footswitch Jack:
t
Ground Lift Switch:
This 3-conductor 1/4” jack is for connecting a
footswitch (sold separately) to the amplifier. The
footswitch will then control the Mute and Solo
features. Using this jack overrides the front panel
MUTE and SOLO switches.
Activating this switch removes the ground
connection on the DIRECT OUTPUT Jack
(#21). Activate this switch, if necessary to
eliminate hum.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Speaker Connection Diagram
TUNER OUT
GROUND
PRE EQ
MODEL: GROOVE 600™
LIFT
POST EQ
BREAKER
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DIRECT OUTPUT
EFFECTS LOOP
ATTENTION
RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR
2001124
SERIAL NUMBER
CAUTION
CHASSIS SURFACE HOT
DESIGNED IN USA
MADE IN CHINA
ATTENTION
SUPERFICE DE CHASSIS CHAUDE
SPEAKER OUTPUT
SEND
RETURN
FOOTSWITCH
Cabinet
Cabinet
A
B
Amplifier Loading Chart
Speaker cabinet
loads (ohms) applied
to the amplifier
Cabinet A’s Impedance (ohms)
open
open
16
8
5.33
5.33
4
3.20
2.67
2.67
2
open
16
16
8
5.33
4.00
3.20
2.67
2.29
2.00
1.60
4
3.20
2.67
2.29
2.00
1.78
1.60
1.33
3.2
2
1.78
1.60
1.45
1.33
1.23
1.14
1.00
16
8
8.00
5.33
4.00
3.20
2.67
2.29
1.78
4.00
3.20
2.67
2.29
2.00
1.78
1.45
2.67
2.29
2.00
1.78
1.60
1.46
1.23
2.29
2.00
1.78
1.60
1.46
1.34
1.14
8
Cabinet
B’s
Impedance
5.33
5.33
4
4
3.20
2.67
2
3.2
2.67
2
Total load on amplifier Note: To prevent overheating and possible loss of signal, do
not use any combination of cabinets that results in a box that is shaded.
This chart can help you determine what load (ohms) is present on the amplifier when using multiple cabinets.
- To use this chart with two cabinets (A and B), find cabinet A’s impedance (ohms) column and cabinet B’s
impedance row on the chart. The total load on the amplifier is shown in the box where they meet. For example: If
cabinet A’s impedance is 8 ohms and cabinet B’s impedance is 4 ohms, the total load on the amplifier would be 2.67
ohms.
- To use this chart with three or more cabinets, find the total load for two cabinets and then use the result for
cabinet A’s impedance column. The third cabinet will then be used for cabinet B’s impedance row on the chart.
Find the total load on the amplifier and repeat if more cabinets are used. For example (using 3 cabinets): If the first
cabinet (cabinet A) has an impedance of 16 ohms and the second (cabinet B) has an impedance of 8 ohms, the
total load would be 5.33 ohms. Using this load (5.33) as cabinet A’s impedance and a third cabinet’s (new cabinet
B) impedance of 4 ohms, you would find that the total load on the amplifier is 2.29 ohms. Note: It is not
recommended to use any combination of cabinets that has a resulting load in a shaded area of the chart.
Alternate Connection Diagrams
TUNER OUT
TUNER OUT
GROUND
PRE EQ
GROUND
LIFT
PRE EQ
1
MODEL: GROOVE 600™
MODEL: GROOVE 600™
LIFT
POST EQ
POST EQ
BREAKER
BREAKER
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DIRECT OUTPUT
EFFECTS LOOP
DIRECT OUTPUT
EFFECTS LOOP
ATTENTION
ATTENTION
RISQUE DE CHOC ELECTRIQUE-NE
PAS OUVRIR
RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR
2001124
2001124
SERIAL NUMBER
SERIAL NUMBER
CAUTION
CHASSIS SURFACE HOT
CAUTION
CHASSIS SURFACE HOT
DESIGNED IN USA
MADE IN CHINA
ATTENTION
SUPERFICE DE CHASSIS CHAUDE
DESIGNED IN USA
MADE IN CHINA
ATTENTION
SUPERFICE DE CHASSIS CHAUDE
SPEAKER OUTPUT
SEND
RETURN
FOOTSWITCH
SPEAKER OUTPUT
SEND
RETURN
FOOTSWITCH
8 Ohms
8 Ohms
8 Ohms
8 Ohms
=
8 Ohms
8 Ohms
8 Ohms
8 Ohms
Total Load On Amplifier = 2 Ohms
Total Load On Amplifier = 2 Ohms
Note: Some efficiency is reduced due to line loss using this method
8
Download from Www.Somanuals.com. All Manuals Search And Download.
GROOVE 600™
Specifications
Model
Groove 600HD
Bass guitar amplifier
Input Impedance
Output Power
200K Ohm
275 Watts
450 Watts
600 Watts
8 Ohms @ 1% THD
4 Ohms @ 1% THD
2 Ohms @ 1% THD
Actual response is tailored to speakers for accurate acoustical
response using a bass guitar as input.
Frequency Response
Hum & Noise
20HZ-20kHz
-60dB
27dB
15dB
25dB
27dB
29dB
Residual Noise, all level controls 0% (minimum)
Preamp output
System Gain
Preamp output, Gain switch set to -12dB
Tuner output
All measurements taken with 1 KHz
input signal, Tone controls flat, Gain and
Volume Maximum. Measured at effects
send output jacks on rear unless noted.
Direct output
Power amp gain
Amplifier Type
Footswitch
Class B
Descrete device Class B amplifier
KAC-GFS100 recommended, but any non-momentary two-button foot switch can be used.
Use any standard tip-ring-sleeve 1/4" cable
USA/Canada
Europe
120VAC/60Hz, 800W nominal
230VAC/50Hz, 800W nominal
Power Requirements
Dimensions
UK
230VAC/50Hz, 800W nominal
Australia
Japan
240VAC/50Hz, 800W nominal
100VAC/50-60Hz, 800W nominal
89 (Height) x 483 (Width) x 390 (Depth), 12 kg
3.5 (Height) x 19 (Width) x 15.5 (Depth), 26 lbs
mm/kg
Inches/Pounds
Rack Mounting Instructions
The GROOVE 600™ was designed to mount into a standard 2-space rack. When mounting, use 4 screws to
secure the amplifier to the rack. When using only one amplifier, use the bottom 2 spaces in the rack.
However, if more than one amplifier is used, leave one space open between the amplifiers to ensure proper
ventilation (shown below).
9-BAND ACTIVE EQ
FLAT
FLAT
FLAT
-12 dB
NORM
-6dB
+6dB
-6dB
+6dB
-6dB
+6dB
-12dB
+12dB -12dB
+12dB -12dB
+12dB
9-BAND ACTIVE EQ
FLAT
FLAT
FLAT
-12 dB
NORM
-6dB
+6dB
-6dB
+6dB
-6dB
+6dB
-12dB
+12dB -12dB
+12dB -12dB
+12dB
9
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
EC Declaration of Conformity
We:
Kustom Musical Amplification Inc.
PO. Box 568
Hebron, Ky 41048-0568
Tel: 1-859-817-7100 Fax: 1-859-817-7150
Declare that the product
Product name:
Kustom
Product model number:
GROOVE 600HD
to which this declaration relates is in conformity with the following standards;
EN55013 (A12) : 1995
Limits and methods of measurement of radio disturbance characteristics of broadcast receivers and
associated equipment.
EN55020: 1995
Electromagnetic immunity of broadcast receivers and associated equipment.
Limits for harmonic current emissions (equipment input current < 16A per phase).
EN61000-3-2: 1995
EN61000-3-3: 1995
Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with
rated currents < 16A.
EN55103-1: 1995
EN60065: 1994
Electromagnetic Compatibility - Product family standard for Audio, Video Audio-visual and
entertainment Lighting Control Apparatus.
Safety requirements for main operated electronic and related apparatus for household and similar
general use.
Following the provisions of EU Council Directive(s): 72/73 EEC and 89/336/EEC.
We the undersigned, hereby declare that the equipment specified above conforms to the aforementioned directive(s).
Name of authorized person: James Brown, VP Engineering
Signature:______________________
Date: 15 DECEMBER 2006
Kustom Amplification Inc.
PO. Box 568
Hebron, Ky 41048-0568
Tel: 1-859-817-7100 Fax: 1-859-817-7150
11
Download from Www.Somanuals.com. All Manuals Search And Download.
®
Kustom Amplification Inc., PO BOX 568, Hebron, KY • USA
Download from Www.Somanuals.com. All Manuals Search And Download.
|