Modular 8-Port Mid-span
Power over Ethernet Injector
KPOE-800-1P
KPOE-800-2P
Installation Guide
DOC.090201
Download from Www.Somanuals.com. All Manuals Search And Download.
The information contained in this document is subject to change without prior notice. Copyright (C)
All Rights Reserved.
TRADEMARKS
Ethernet is a registered trademark of Xerox Corp.
FCC NOTICE
This device complies with Class A Part 15 the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received including the interference that may cause.
CE NOTICE
Marking by the symbol indicates compliance of this equipment to the EMC directive of the European
Community. Such marking is indicative that this equipment meets or exceeds the following technical
standards:
EMC Class A
EN 50081-1/1992 :EN55022:1994/A1:1995/A2:1997 Class A
EN61000-3-2:2000
EN61000-3-3:1995/A1:2001
EN 55024:1998/A1:2001
IEC 61000-4-2:1995
IEC 61000-4-3:1995
IEC 61000-4-4:1995
IEC 61000-4-5:1995
IEC 61000-4-6:1996
IEC 61000-4-8:1993
IEC 61000-4-11:1994
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
1. Introduction ................................................................................................................................5
1.4 Model Definition.....................................................................................................7
2. Installation ..................................................................................................................................9
2.5 Applying AC Power..............................................................................................13
3. Making LAN Connections........................................................................................................14
3.1 Making Switch Port Connections.........................................................................14
3.2 Making Powered Device Connections.................................................................15
4.2 Application with High Power Requirements.........................................................17
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Introduction
The Power over Ethernet (PoE) injector is a mid-span power injector designed and tested for use with
all IEEE802.3af compatible PoE Powered Devices (PDs). The PoE injector sits between a switch port
and the PoE powered device, providing inline power capability to an un-powered switch port.
The injector provides modular power design. For high power applications, the injector can be installed
with 2 power modules to support full PoE power up to 120W for eight powered devices. For low
power applications, the injector can work with only one power module and support PoE power up to
60W for eight connections. This flexible modular power design provides cost-effective solutions for
different requirements.
The PoE injector offers the following significant benefits:
ꢀ
ꢀ
ꢀ
Low purchase cost - Installing an injector costs less than upgrading to new PoE switches, since
PoE injectors can easily connect with existing Ethernet switches.
Low installation cost - The injector is a plug & play product making the installation much easier
than a PoE switch. There is no need any software configuration.
Protecting existing and future investment – The PoE injectors are interoperable with all Ethernet
switches and most terminals. PoE injectors can be used in conjunction with different switch
vendors, and end-terminals, which comply with the PoE 802.3af standard. It protects your existing
network installation and future investment as well.
1.1 Features
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Supports 8 Ethernet ports
Full IEEE802.3af compliance
Gigabit Ethernet support
Transparent to switch functionality
Standard user safety protection
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀ
ꢀ
Modular PoE power upgradability
19" rack mounting support
1.2 Product Panels
The following figure illustrates the faces of the injector:
1.3 Mid-span Injector Function
The PoE mid-span power injector is designed and tested for use with all IEEE802.3af compatible PoE
PDs. The PoE injector sits between a switch port and the PoE powered device, providing inline power
capability to an un-powered switch port.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
1.4 Model Definition
KPOE-800-1P
1 Power Model
The injector unit with one pre-installed power module
The injector unit with two pre-installed power modules
PoE 60W Power Module
KPOE-800-2P
2 Power Model
Power Module
KPOE-800P60W
KPOE-800BSET1
KPOE-800BSET2
BRACKET SET1
BRACKET SET2
The bracket set for mounting one unit in a 19” rack
The bracket set for mounting two units in a 19” rack
1.5 Specifications
Network Ports
8 connections to 8 non-PoE switched ports
8 connections to 8 PoE powered devices
Ethernet Ethernet, Fast Ethernet & Gigabit Ethernet
IEEE 802.3af compliance
Compatible Std.
PoE Standard
Data IN Jack
Shielded RJ-45
IEEE 802.3, 10Base-T, 100Base-TX, 1000Base-T std.
Hot-plug support
PoE OUT Jack
PoE OUT Cable
Shielded RJ-45
IEEE 802.3, 10Base-T, 100Base-TX, 1000Base-T std.
Hot-plug support
4-pair Cat.5, 5e, or 6
Distance mid-span up to 100 meters
48VDC on jack pin 4/5 (V48dc+) and jack pin 7/8 (V48dc-)
Total 60 Watts for 8 connections with one power module
Total 120 Watts for 8 connections with two power modules
PoE OUT Voltage
PoE OUT Power
PoE OUT Protection Port power shut down protection for events:
- Incompliant PD detection,
7
Download from Www.Somanuals.com. All Manuals Search And Download.
- Disconnection,
- Overload,
- Over-current
- Short-circuit,
- Under voltage
Power Module Slots
LED Indicators
Power Input
2
Power module status x 2 , Port PoE status x 8
Voltage: 100 ~ 240VAC, Frequency: 50/60Hz
1 Power Model: 68W max. (60W for remote PoE PDs)
2 Power Model: 136W max. (120W for remote PoE PDs)
1 Power Model: 3W
Power Consumption
Power Dissipation
2 Power Model: 6W
Dimension
190 x 238 x 43 mm (WxDxH)
Enclosed metal with no fan
19" rack mountable
Housing
Mounting Support
Temperature
Operating: 0oC ~ +40oC, Storage: -20oC ~ 85oC
Relative humidity: 5 ~ 95% non-condensing
Certificate
FCC
Part 15 Class A
EMI EN50081-1 Class A
EMS EN55024
EN 60950
CE/EMC
CE/LVD Safety
EN 50081-1/1992 :
EN55022:1994/A1:1995/A2:1997
EN61000-3-2:2000
EN61000-3-3:1995/A1:2001
EN 55024:1998/A1:2001
IEC 61000-4-2:1995 ESD Test
IEC 61000-4-3:1995 RS Test
IEC 61000-4-4:1995 EFT/BURST Test
IEC 61000-4-5:1995 Surge Test
IEC 61000-4-6:1996 CS Test
IEC 61000-4-8:1993 Magnetic Field
IEC 61000-4-11:1994 Voltage Int. Dips
8
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Installation
2.1 Unpacking
Check that the following components have been included:
ꢀ Information CD
ꢀ The device unit
ꢀ An AC power cord
If any item is found missing or damaged, please contact your local reseller for replacement.
The following are available optional accessories:
ꢀ 19” rack mounting bracket kits
The brackets are used for mounting the devices in a 19” rack.
ꢀ PoE 60W Power Module
The module is used for upgrading the mid-span injector power up to 120W.
2.2 Safety Cautions
To reduce the risk of bodily injury, electrical shock, fire, and damage to the product, observe the
following precautions.
ꢀ
ꢀ
ꢀ
ꢀ
Do not service any product except as explained in your system documentation.
Opening or removing covers may expose you to electrical shock.
Only a trained service technician should service components inside these compartments.
If any of the following conditions occur, unplug the product from the electrical outlet and replace
the part or contact your trained service provider:
- The power cable, extension cable, or plug is damaged.
- An object has fallen into the product.
- The product has been exposed to water.
- The product has been dropped or damaged.
- The product does not operate correctly when you follow the operating instructions.
ꢀ
ꢀ
Do not push any objects into the openings of your system. Doing so can cause fire or electric shock
by shorting out interior components.
Operate the product only from the type of external power source indicated on the electrical ratings
label. If you are not sure of the type of power source required, consult your service provider or
local power company.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3 Mounting the Injector
Desktop Mounting
The injector can be mounted on a desktop or shelf. Make sure there is proper heat dissipation from and
adequate ventilation around the device. Do not place heavy objects on the device.
Rack Mounting
The following brackets are designed for use to mount the devices in a 19” rack.
Mounting one unit in a rack
Use the bracket set1 and follow the steps shown below:
ꢁShort bracket x 1
ꢁLong bracket x 1
1. Install the short bracket to one side of the device.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Install the long bracket to the other side of the device.
3. Mount the device in a 19” rack.
Mounting two units in a rack
Use the bracket set 2 and follow the steps shown below:
ꢁShort bracket x 4
ꢁJoint bracket x 1
1. Install two short brackets to both sides of each device.
2. Joint two units together as shown below:
11
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Mount two device units as one in a 19” rack.
2.4 Installing Power Module
If you purchased 2 Power Model, you may skip this section. 1 Power Model can deliver total up to
60W for consuming by all eight ports. Calculate the total power budget required for your PD
connections before making any connections.
Most of common PoE powered devices such as wireless Access Points, VoIP phones, IP cameras and
media converters consume power less than 5Watts. However, refer to the product technical
information of individual PD you are using for the power consumption.
If total PoE power more than 60W is required, install one extra power module to the 1 Power injector.
The steps are:
1. Unplug the AC power cord before any installation.
2. Open the cover of the empty module slot.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Install the power module into the slot until it is seated properly.
4. Screw the module in the injector securely.
2.5 Applying AC Power
One AC power cord, which meets the specification of your country of origin was supplied with the
device unit. The device supports wide range of AC power input specifications as follows:
Specifications
Power Rating:
100 ~ 240VAC, 50/60Hz
90 ~ 264VAC
Voltage Range:
Frequency :
47 ~ 63 Hz
Power Consumption
1 Power Model:
2 Power Model:
Power Dissipation
1 Power Model:
2 Power Model:
68W max. (including 60W for remote PoE PDs)
136W max. ( including 120W for remote PoE PDs)
3W
6W
13
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Making LAN Connections
3.1 Making Switch Port Connections
The mid-span injector is designed to support the following PoE incapable switch port types and the
PoE function is transparent and independent to the following port configuration:
IEEE 802.3 std.
10BASE-T
100BASE-TX
1000BASE-T
Port Configuration
Auto-negotiation:
Enable or disable
Transmission speed: 10Mbps, 100Mbps, 1000Mbps
Duplex:
Half duplex, full duplex
MDI or MDI-X
Jack Pins:
Network Cables
10BASE-T:
2-pair UTP Cat. 3, 4, 5, EIA/TIA-568B 100-ohm
100BASE-TX: 2-pair / 4-pair UTP Cat. 5, EIA/TIA-568B 100-ohm
1000BASE-T: 4-pair UTP Cat. 5, Cat.5e, Cat.6, EIA/TIA-568B 100-ohm
To make a switch port connection, the steps are:
1. Find an appropriate network cable for a port connection.
2. Connect one end of the cable to the PoE-incapable switch port.
3. Connect the other end to one available DATA IN jack of the PoE injector.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2 Making Powered Device Connections
The mid-span injector supports connection to IEEE 802.3af compliant PoE PD (Powered Device). The
Ethernet port of the PD can be Ethernet, Fast Ethernet or Gigabit Ethernet. The injector’s PoE OUT
port delivers power together with network signal to a connected powered device via Cat.5 cable or
better.
To make a connection, the following check points should be noted:
1. For safety reason, the connected PD must be a IEEE 802.3af-compliant device. Un-compliant
devices are not supported.
2. The Cat.5 cables used for the connections must be 4-pair cables. The power is sent over the pairs
(4,5) (7,8) of the cable.
3. Hot-plug connection is allowed anytime.
PoE OUT Port Power
Voltage
48VDC on jack pin 4/5 (V48dc+) and jack pin 7/8 (V48dc-)
15.4W maximum per port
Power (per port)
Power (per unit)
1 Power Model - 60W for all 8 PoE OUT ports
2 Power Model - 120W for all 8 PoE OUT ports
Connection Distance
Safety Protection
The injector provides safety protection design for operation. The individual power output of each PoE
OUT port is shut down when any of the following events occurs:
Incompliant PD
Disconnection
Overload
An incompliant PD is detected on the port.
A PD disconnection.
An overload situation is detected on the port.
An over-current situation is detected on the port.
Over-current
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Short-circuit
Under voltage
A short-circuit situation is detected on the port.
An under-voltage situation is detected on the port.
3.3 LED Indication
LED
Function
State
ON
Interpretation
P1
Power 1 status
Power 1 is ON.
OFF
ON
Power 1 is OFF.
Power 2 is ON.
P2
Power 2 status
OFF
Power 2 is OFF.
Port PoE power is ON.
Port PoE power is OFF.
1 ~ 8
Port 1 ~ Port 8 PoE status ON
OFF
16
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Applications
4.1 Application with Low Power Requirements
1 Power model may be used if the total power budget of the connected PDs is less than 60Watts. One
empty slot can be upgraded with one more power if total power budget increased and is more than
60W in future.
4.2 Application with High Power Requirements
2 Power model can support the total power budget up to 120Watts for all connected PDs.