Kramer Electronics Water Pump fc 42 User Manual

KRAMER ELECTRONICS LTD.  
USER MANUAL  
MODEL:  
FC-42  
Component to HD-SDI  
Converter  
P/N: 2900-000384 Rev 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Introduction  
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been  
providing a world of unique, creative, and affordable solutions to the vast range of  
problems that confront video, audio, presentation, and broadcasting professionals  
on a daily basis. In recent years, we have redesigned and upgraded most of our  
line, making the best even better!  
Our 1,000-plus different models now appear in 11 groups that are clearly defined  
by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers;  
GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5:  
Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7:  
Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9:  
Room Connectivity; GROUP 10: Accessories and Rack Adapters and GROUP 11:  
Sierra Products.  
Congratulations on purchasing your Kramer FC-42 Component to HD-SDI  
Converter, which is ideal for the following typical applications:  
Broadcast and production video studios  
Postproduction and duplication studios  
Non-linear editing  
FC-42 - Introduction  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
Getting Started  
We recommend that you:  
Unpack the equipment carefully and save the original box and packaging  
materials for possible future shipment  
Review the contents of this user manual  
Go to http://www.kramerelectronics.com to check for up-to-date  
user manuals, application programs, and to check if firmware  
upgrades are available (where appropriate).  
i
2.1  
Achieving the Best Performance  
To achieve the best performance:  
Use only good quality connection cables (we recommend Kramer high-  
performance, high-resolution cables) to avoid interference, deterioration in  
signal quality due to poor matching, and elevated noise levels (often  
associated with low quality cables)  
Do not secure the cables in tight bundles or roll the slack into tight coils  
Avoid interference from neighboring electrical appliances that may adversely  
influence signal quality  
Position your Kramer FC-42 away from moisture, excessive sunlight and  
dust  
This equipment is to be used only inside a building. It may only be  
connected to other equipment that is installed inside a building.  
!
2
FC-42 - Getting Started  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.2  
Safety Instructions  
Caution:  
There are no operator serviceable parts inside the unit  
!
Warning: Use only the power cord that is supplied with the unit  
Warning: Do not open the unit. High voltages can cause  
electrical shock! Servicing by qualified personnel only  
Warning: Disconnect the power and unplug the unit from the wall  
before installing  
2.3  
Recycling Kramer Products  
The Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC  
aims to reduce the amount of WEEE sent for disposal to landfill or incineration by  
requiring it to be collected and recycled. To comply with the WEEE Directive,  
Kramer Electronics has made arrangements with the European Advanced  
Recycling Network (EARN) and will cover any costs of treatment, recycling and  
recovery of waste Kramer Electronics branded equipment on arrival at the EARN  
facility. For details of Kramer’s recycling arrangements in your particular country  
FC-42 - Getting Started  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3
Overview  
The Kramer FC-42 is a high performance converter for high definition (HD)  
component video (Y, PB, PR). It converts the component video input  
(Y, PB, PR) to HD-SDI on two BNC output connectors. The signal is also converted  
to an RGB/HV signal on a 15-pin HD computer graphics video connector.  
In addition, the FC-42 features:  
HDTV compatibility  
Multi-standard operation: SDI (SMPTE 259M and SMPTE 344M) & HD−SDI  
(SMPTE 292M)  
HD resolutions of 720p and 1080i (up to 60Hz) & 1080p (up to 30Hz)  
Bi−level and tri−level sync input  
No resolution conversion  
ProcAmp control with memory for 16 setups  
A test pattern generator with eight patterns  
Control using the front panel with LCD display and RS−232  
A worldwide power supply - 100−240V AC  
Standard 19” rack mount size of 1U with included rack “ears”  
3.1  
Defining the FC-42 Component to HD-SDI Converter  
This section defines the FC-42.  
4
FC-42 - Overview  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Figure 1: FC-42 Component to HD-SDI Converter Front Panel  
#
Feature  
Function  
1
POWER Switch  
SETUP / MENU LCD Display  
MENU Button  
ENTER Button  
Button  
Illuminated switch for turning the unit ON or OFF  
Displays the setup and the menu  
2
3
4
5
6
7
8
9
Press to open the menu (see Section 6.2)  
Press to load and save a set up, and to accept changes  
Press to decrease numerical values or select from several definitions  
Press to move up the menu list values  
Button  
Button  
Press to increase numerical values or select from several definitions  
Press to move down the menu list  
Button  
LOCK Button  
Press and hold for about 3 seconds to lock/unlock the front panel buttons  
FC-42 - Overview  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 2: FC-42 Component to HD-SDI Converter Rear Panel  
#
Feature  
Y BNC Connector  
Function  
10  
11  
12  
13  
14  
15  
16  
17  
INPUTS  
PB BNC Connector  
Connects to a component video source  
PR BNC Connector  
SDI BNC Connector  
Connects to an HD-SDI acceptor  
OUTPUTS  
SDI (bar) BNC Connector  
RGB/HV 15-pin HD Connector  
Connects to an HD-SDI acceptor (reclocked and equalized)  
Connects to an RGB/HV acceptor  
RS-232 9-pin D-sub Port  
Connect to the PC or the remote controller  
AC connector, enabling power supply to the unit  
Power Connector with Fuse  
6
FC-42 - Overview  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4
Installing in a Rack  
This section provides instructions for rack mounting the unit.  
FC-42 - Installing in a Rack  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5
Connecting the FC-42  
Always switch off the power to each device before connecting it to your  
FC-42. After connecting your FC-42, connect its power and then switch  
i
on the power to each device.  
To connect the FC-42, as illustrated in the example in Figure 3, do the following:  
1. Connect a component video source (for example, an HDTV Satellite receiver  
source) to the Y, PB, PR INPUT BNC connectors.  
2. Connect the OUTPUTS:  
.
.
.
Connect the SDI BNC connector to an HD-SDI acceptor (for example,  
a non-linear editor)  
Connect the SDI BNC connector to an HD-SDI acceptor (for example,  
an HD-SDI display)  
Connect the RGB/HV 15-pin HD computer graphics video connector to  
an RGBHV acceptor (for example, a projector)  
3. Connect a PC or other controller, if required (see Section 5.1).  
4. Connect the power cord (not shown in Figure 3).  
8
FC-42 - Connecting the FC-42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 3: Connecting the FC-42 Component to HD-SDI Converter  
FC-42 - Connecting the FC-42  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5.1  
Connecting to the FC-42 via RS-232  
You can connect to the unit via a crossed RS-232 connection, using for example,  
a PC. A crossed cable or null-modem is required as shown in method A and B  
respectively. If a shielded cable is used, connect the shield to pin 5.  
Method A (Figure 4)Connect the RS-232 9-pin D-sub port on the unit via a  
crossed cable (only pin 2 to pin 3, pin 3 to pin 2, and pin 5 to pin 5 need be  
connected) to the RS-232 9-pin D-sub port on the PC.  
Note: There is no need to connect any other pins.  
5
4
3
2
1
5
4
3
2
1
9
8
7
6
9
8
7
6
PC  
Figure 4: Crossed Cable RS-232 Connection  
Hardware flow control is not required for this unit. In the rare case where a  
controller requires hardware flow control, short pin 1 to 7 and 8, and pin 4 to 6 on  
the controller side.  
Method B (Figure 5)Connect the RS-232 9-pin D-sub port on the unit via a  
straight (flat) cable to the null-modem adapter, and connect the null-modem  
adapter to the RS-232 9-pin D-sub port on the PC. The straight cable usually  
contains all nine wires for a full connection of the D-sub connector. Because the  
null-modem adapter (which already includes the flow control jumpering described  
in Method A above) only requires pins 2, 3 and 5 to be connected, you are free to  
decide whether to connect only these 3 pins or all 9 pins.  
5
9
4
8
Null-Modem  
Adapter  
3
to PC  
7
2
6
1
Figure 5: Straight Cable RS-232 Connection with a Null Modem Adapter  
10  
FC-42 - Connecting the FC-42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
6
Using the FC-42 Component To HD-SDI  
Converter  
This section describes how to:  
Lock/unlock the front panel button, see Section 6.1  
Operate the FC-42, see Section 6.2  
6.1  
Locking the Front Panel  
To prevent changing the settings accidentally or tampering with the unit via the  
front panel buttons, lock your converter. Unlocking releases the protection  
mechanism.  
Even though the front panel is locked you can still operate via RS-232.  
To lock the converter:  
Press the LOCK button for more than three seconds, until the LOCK button  
is illuminated  
The front panel is locked. Pressing a button has no effect other than causing  
the LOCK button to flash  
Warning that you need to unlock to regain control via the front panel.  
To unlock the converter:  
Press the illuminated LOCK button for more than three seconds, until the  
LOCK button is no longer illuminated  
The front panel unlocks  
6.2  
Operating the FC-42 HD-SDI to Component Converter  
The converter can save and load up to 16 setups via the converter menu. To use  
the menu, press the:  
MENU button to start or exit the menu  
ENTER button to enter a submenu, load a setup, accept changes and reset  
to the default settings  
and buttons to scroll through the menu and sub-menus  
FC-42 - Using the FC-42 Component To HD-SDI Converter  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
and to increase or decrease numerical values or select from several  
definitions of a setup  
The converter automatically converts the input signal according to the setup  
loaded from the menu. The setup is defined via the menu. To operate the  
converter, press the MENU button to enter the menu, and load the desired setup  
(from 1 to 16). The following table defines the menu items.  
#
Menu Item  
LOAD … SETUP  
SAVE SETTING AS  
Submenu  
Select  
From 1 to 16  
Notes  
Refers to the setup  
number (from 1 to 16)  
1
2
3
From 1 to 16  
SET … STANDARD  
AUTO, FORCED  
SELECT MODE  
4
SET … STANDARD  
720p/59, 720p/50,  
1080i/60, 1080i/59,  
1080i/50,  
1080p/30, 1080p/29,  
1080p/25, 1080p/24,  
1080p/23,  
1080sf/30, 1080sf/29,  
1080sf/25, 1080sf/24,  
1080sf/23  
5
6
SET … SYNC TYPE  
BILEVEL, TRILEVEL  
SET … IMAGE TUNING 1 FACTORY RESET  
(enter submenu)  
Sets all the image  
tuning parameters to  
zero  
2 BLACK  
3 Y-GAIN  
4 GAIN  
From -32 to 31  
From -64% to 63%  
From -64% to 63%  
From -64% to 63%  
From -64% to 63%  
From -64% to 63%  
From 0 to 155%  
5 COLOR  
6 B-Y  
7 R-Y  
8 SHARPNESS  
In 5% steps  
7
SET … Test signal  
NO TEST SIGNAL  
1 COLOR BARS 100%  
2 Y-SWEEP 30MHZ  
3 PULSE 2T AND BAR  
4 Y RAMP  
5 C-SWEEP 15MHZ  
6 SPLIT BARS  
7 GRID  
8 GRID INVERSE  
8
9
SET … Free run mode  
BLACK SCREEN, BLUE  
SCREEN  
SET … Address of  
First, Second  
machine  
12  
FC-42 - Using the FC-42 Component To HD-SDI Converter  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Technical Specifications  
INPUT:  
1 component video - Y, PB, PR, on 3 BNC connectors  
OUTPUTS:  
2 SDI on BNC connectors  
1 RGB/HV on a 15-pin HD connector  
OUTPUT LEVEL:  
RESOLUTION:  
S/N RATIO:  
800mVpp  
Up to 1080p  
49dB unweighted  
CONTROLS:  
Front panel buttons: MENU, ENTER, menu arrows,  
LOCK;  
rear panel: RS-232  
POWER CONSUMPTION:  
OPERATING TEMPERATURE:  
STORAGE TEMPERATURE:  
HUMIDITY:  
100-240V, 50/60Hz, 200mA Max. 12VA  
0° to +40°C (32° to 104°F)  
-40° to +70°C (-40° to 158°F)  
10% to 90%, RHL non-condensing  
19" x 7" x 1U (W, D, H) rack mountable  
2.6kg (5.7lbs) approx.  
DIMENSIONS:  
WEIGHT:  
ACCESSORIES:  
Power cord, null-modem adapter  
Specifications are subject to change without notice at http://www.kramerelectronics.com  
FC-42 - Technical Specifications  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8
Communication Protocol  
The FC-42 is compatible with the protocol (ver 1.2) described below. For RS-232,  
a null-modem connection between the FC-42 and controller is used. The default  
data rate is 9600 baud, with no parity, 8 data bits and 1 stop bit. All the values  
shown are hexadecimal.  
Instruction  
Byte 1  
Byte 2  
Byte 3  
Byte 4  
Notes:  
RESET  
00  
80  
80  
98+Machine  
Addr  
REPLY TO  
RESET  
40  
20  
60  
80  
80  
98+Machine  
Addr  
READ LOCAL  
PARAMETER  
80+Parameter 80  
Number  
B8+Machine  
Addr  
REPLY TO READ  
LOCAL  
PARAMETER  
80+Parameter 80+Parameter  
Number  
B8+Machine  
Addr  
Data  
WRITE LOCAL  
PARAMETER  
21  
61  
80+Parameter 80+Parameter  
Number Data  
80+Parameter 80+Parameter  
Number Data  
B8+Machine  
Addr  
REPLY TO  
WRITE LOCAL  
PARAMETER  
B8+Machine  
Addr  
1
READ GLOBAL  
PARAMETER  
20  
60  
80+Parameter 80  
Number  
98+Machine  
Addr  
REPLY TO READ  
GLOBAL  
PARAMETER  
80+Parameter 80+Parameter  
98+Machine  
Addr  
Number  
Data  
WRITE GLOBAL  
PARAMETER  
21  
61  
80+Parameter 80+Parameter  
Number  
98+Machine  
Addr  
Data  
80+Parameter 80+Parameter  
REPLY TO  
WRITE GLOBAL  
PARAMETER  
98+Machine  
Addr  
1
2
Number  
Data  
SAVE  
23  
80 + Initial  
Setup  
80+Destination  
Setup Number  
98+Machine  
Addr  
Number  
IDENTIFY  
MACHINE  
3D  
3D  
81  
80  
80  
98+Machine  
Addr  
3
4
IDENTIFY  
FIRMWARE  
VERS.  
83  
98+Machine  
Addr  
14  
FC-42 - Communication Protocol  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
The following table defines the local parameter data:  
Local Parameter Number  
Local Parameter Data  
Description  
#
0 - 720p/60  
1 - 720p/59  
2 - 720p/50  
3 - 1080i/60  
4 - 1080i/59  
5 - 1080i/50  
6 - 1080p/30  
7 - 1080p/29  
Input Standard  
01  
8 - 1080p/25  
9 - 1080p/24  
A - 1080p/23  
B - 1080sf/30  
C - 1080sf/29  
D - 1080sf/25  
E - 1080sf/24  
F - 1080sf/23  
0 - Auto  
Mode Input Standard  
SYNC Type  
02  
04  
1 - Forced  
0 - Bi-Level  
1 - Tri-Level  
0 - NO TEST SIGNAL  
1 - COLOR BAR 100%  
2 - Y-SWEEP 30 MHZ  
3 - PULSE 2T AND BAR  
4 - Y-RAMP  
Test Signal  
05  
5 - C-SWEEP 15 MHZ  
6 - RAINBOW  
7 - GRID  
8 - GRID INVERSE  
-32% - +31% (1% step)  
-64% - +63% (1% step)  
-64% - +63% (1% step)  
-64% - +63% (1% step)  
-64% - +63% (1% step)  
-64% - +63% (1% step)  
0% - +150% (10% step)  
Black  
Y-gain  
Gain  
08  
09  
0A  
0B  
0C  
0D  
0E  
Color  
B-Y  
R-Y  
Sharpness  
FC-42 - Communication Protocol  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The following table defines the global parameter data:  
Global Parameter Number  
Global Parameter Data  
Description  
#
0 - Off (Default)  
1 - On  
Panel Lock  
00  
Machine Address  
Setup Number  
01  
02  
0,1  
0 - 15  
0 - Black Screen (Default)  
1 - Blue Screen  
0 - 720p/60  
Free Run Mode  
03  
08  
09  
1 - 720p/59  
2 - 720p/50  
3 - 1080i/60  
4 - 1080i/59  
5 - 1080i/50  
6 - 1080p/30  
7 - 1080p/29  
8 - 1080p/25  
9 - 1080p/24  
A - 1080p/23  
B - 1080sf/30  
C - 1080sf/29  
D - 1080sf/25  
E - 1080sf/24  
F -1080sf/23  
10 - Not Identified  
11 - Not Identified  
0 - Input Signal is Present  
1 - No Input Signal  
Input Standard  
(Read Only)  
(AUTO Mode Only)  
Presence of Input Signal  
(Read Only)  
NOTE 1: These commands are sent by the unit also when Local / Global parameters are changed via the front panel or  
as a result of execution of any other command.  
NOTE 2: If it is necessary merely to save adjusted parameters in initial setup number (no setup number change), then  
the value of byte3 must be equal to the value of byte2 - initial setup number.  
NOTE 3: The reply to the Identify Machine command shows the machine name  
- 1st byte: 0x7d  
- 2nd byte: 0x80 + 0x00 (0 dec)  
- 3rd byte: 0x80 + 0x29 (41 dec) - for the unit FC-42  
- 4th byte: 0x98  
NOTE 4: The reply to the Identify Firmware command shows the firmware version as  
- 1st byte: 0x7d  
- 2nd byte: 0x80 + the version number prior to decimal point  
- 3rd byte: 0x80 + the version number following the decimal point  
- 4th byte: 0x98  
For example, for version 3.5, the reply would be 0x7d, 0x83, 0x85, 0x98.  
16  
FC-42 - Communication Protocol  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For the latest information on our products and a list of Kramer distributors,  
visit our Web site where updates to this user manual may be found.  
We welcome your questions, comments, and feedback.  
SAFETY WARNING  
Disconnect the unit from the power  
supply before opening and servicing  
!
P/N:  
Rev:  
2900- 000384  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ingersoll Rand Biscuit Joiner 651840 1 GL User Manual
Intel Switch SGI Altix 450 User Manual
Jensen Portable Speaker JCCSPK User Manual
Jet Tools Planer 6 HH User Manual
JVC Camera Accessories WR MG100 User Manual
Kalorik Egg Cooker GR38892 User Manual
Karcher Pressure Washer K4400G User Manual
Kenwood Mixer FP730 User Manual
Kodak Digital Photo Frame D1030 User Manual
Kramer Electronics TV Converter Box FC 49 User Manual