Kramer Electronics TV Cables 2900 3000730 Rev 2 User Manual

KRAMER ELECTRONICS LTD.  
USER MANUAL  
MODEL:  
MODULAR TBUS-6xl  
Table Connection Bus  
P/N: 2900-300073 Rev 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Introduction  
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been  
providing a world of unique, creative, and affordable solutions to the vast range of  
problems that confront the video, audio, presentation, and broadcasting  
professional on a daily basis. In recent years, we have redesigned and upgraded  
most of our line, making the best even better!  
Our 1,000-plus different models now appear in 11 groups that are clearly defined  
by function: GROUP 1: Distribution Amplifiers, GROUP 2: Switchers and Matrix  
Switchers, GROUP 3: Control Systems, GROUP 4: Format/Standards Converters,  
GROUP 5: Range Extenders and Repeaters, GROUP 6: Specialty AV Products,  
GROUP 7: Scan Converters and Scalers, GROUP 8: Cables and Connectors,  
GROUP 9: Room Connectivity, GROUP 10: Accessories and Rack Adapters, and  
GROUP 11: Sierra Products.  
Thank you for purchasing the Kramer TBUS-6xl enclosure, which is ideal for  
boardrooms, conference and training rooms!  
Note that the inner frame, power socket assembly, power cord and  
other inserts for the TBUS-6xl enclosure are purchased separately.  
i
TBUS-6xl - Introduction  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
Getting Started  
We recommend that you:  
Unpack the equipment carefully and save the original box and packaging  
materials for possible future shipment  
Review the contents of this user manual  
Use Kramer high-performance high-resolution cables  
Go to http://www.kramerelectronics.com to check for up-to-date  
user manuals, a complete list of Kramer wall plates and module  
connectors, application programs, and to check if firmware  
upgrades are available (where appropriate).  
i
2.1  
Achieving the Best Performance  
To achieve the best performance:  
Use only good quality connection cables to avoid interference, deterioration  
in signal quality due to poor matching, and elevated noise levels (often  
associated with low quality cables)  
Avoid interference from neighboring electrical appliances that may adversely  
influence signal quality  
Position your Kramer TBUS-6xl away from moisture, excessive sunlight and  
dust  
2.2  
Glossary  
Inner frame  
The inner frame fits into the TBUS enclosure  
Universal socket The Universal socket fits almost all power cords, worldwide  
Insert  
The insert is fitted in the inner frame. Go to our Web site to check for a  
variety of single and dual sized inserts  
2
TBUS-6xl - Getting Started  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
3
Overview  
The Kramer TBUS-6xl is a high-quality, anodized aluminum, table-mounted  
connection bus enclosure for boardrooms and conference rooms. Its attractive  
enclosure is designed to provide maximum connectivity in the smallest possible  
footprint. The unit is sturdy, cost-effective, and easy to install.  
The TBUS-6xl includes:  
A modular design, letting you tailor the TBUS-6xl according to your  
requirements  
A black anodized or brushed clear aluminum lid with a special opening for  
cable pass-through (note, that other customized colors can also be ordered)  
Height adjustment screw holes to set the inner frame (ordered separately) to  
the desired height  
Power socket openings that are suitable for any of the following power  
sockets: for the USA, Germany (the Europlug), Belgium-France, Italy,  
Australia, Israel, South Africa or “Universal” for use anywhere (see  
compatibility restrictions in Section 7)  
Order the power sockets separately from Kramer Electronics  
An optional insert kit to replace one power socket  
The insert kit can include two wall plate module inserts, two cable pass-through  
connectors, or one of each  
The TBUS-6xl is height-adjustable. The cover that opens and closes manually  
retracts into the unit to remain out of sight when the TBUS-6xl is in use. When  
closed, all cables and connectors are out of sight under the anodized cover.  
Do not place heavy objects on top of the TBUS-6xl.  
!
TBUS-6xl - Overview  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4
Your TBUS-6xl Enclosure  
Figure 1: TBUS-6xl Enclosure Top View  
#
Feature  
Function  
1
2
Black Anodized/Brushed Includes an opening for cable pass-through; covers the inner  
Clear Textured Lid  
Outer Rim  
frame, leaving the table surface neat and tidy  
Fits over the table surface.  
A protective rubber guard protects the outer rim during  
shipping. Remove it before installing the unit  
3
4
Lid Housing  
When opened, the lid retracts into the lid housing  
Rubber Protectors  
Protect the table surface when mounting the unit (one for  
each clamp)  
5
6
7
Locking Butterfly  
Screws  
Tighten to lock the mounting butterfly screw (one for each  
clamp)  
Mounting Butterfly  
Screws  
Tighten to secure the unit to the table surface (one for each  
clamp)  
Mounting Brackets Fit in the bracket slits after inserting the enclosure into the  
table – to secure the unit to the table surface (one for each  
clamp)  
8
9
Bracket Slits  
For attaching the two mounting brackets on opposite sides  
Height Adjustment  
Screw holes  
The screw holes on each side panel are used for adjusting the  
height of the Inner Frame  
10 Tie Holes  
11 Enclosure  
Insert the self-locking tie through the holes to fix the pass-  
through cables to the inside walls of the unit  
Inserted into the table cut out  
4
TBUS-6xl - Your TBUS-6xl Enclosure  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4.1  
TBUS-6xl Optional Inner Frames  
The following inner frames can be installed in the TBUS-6xl enclosure:  
Inner Frames for TBUS-6xl  
Specifications (defines what you can  
include in this inner frame):  
T6F-2S (P/N: 80-004399)  
2 openings for 2 power sockets  
2 RJ-45 connectors  
2 USB connectors  
Two 3.5mm mini jack AUDIO connectors  
2 VGA 15-pin HD connectors  
T6F-23 (P/N: 80-004499)  
2 openings for 2 power sockets  
2 blank inserts  
1 pass-through insert  
T6F-03M (P/N: 80-005499)  
An opening for 1 MegaTOOL, specially  
designed for the Kramer SID-X1  
3 blank inserts  
Custom made inner frames can be designed if required.  
Contact Kramer Electronics for more details.  
i
4.2  
TBUS-6xl Optional Inserts  
Accessories  
Description  
Inserts  
You can install any wall plate devices as well as any of  
the single or dual inserts—see our Web site for details.  
T-2INSERT (P/N: 80-00006699)  
The T-2INSERT kit can be installed inside a single  
power socket opening and includes:  
1 single cable pass-through insert  
1 dual cable pass-through insert  
TBUS-6xl - Your TBUS-6xl Enclosure  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4.3  
Power Socket Options  
A choice of power sockets per inner frame are available in several versions,  
including power sockets for the USA, Germany (the Europlug), Belgium-France,  
Italy, South Africa, Israel and Australia. A “Universal” socket for general use is also  
available (see the compatibility restrictions in the table below).  
Power Socket Power Specs  
Type  
Power Socket  
Type  
Power Specs  
Universal:  
TS/1U (80-000899)  
Fully compatible with power plugs in the  
UK, India, Italy and Denmark, as well as  
with the 2-prong Europlug.  
100-240V AC, 50/60Hz,  
5A  
Partially compatible (if the polarity is  
reversed) with plugs in China, Switzerland,  
Israel and the USA. The universal socket  
does not supply grounding to plugs in  
Central Europe and France and so you  
should order country specific sockets  
instead.  
Maximum 5A per power  
outlet  
Not compatible with South African plugs.  
Power Socket Power Specs  
Type  
Power  
Socket Type  
Power Specs  
USA:  
TS-1US (80-000999)  
Italy:  
TS-1IT (80-001499)  
100-240V AC, 50/60Hz, 5A  
100-240V AC, 50/60Hz, 5A  
Maximum 5A per power  
outlet  
Maximum 5A per power  
outlet  
Germany and  
EU:  
TS-1DE (80-001299)  
Australia:  
TS-1AU (80-001599)  
100-240V AC, 50/60Hz, 5A  
100-240V AC, 50/60Hz, 5A  
Maximum 5A per power  
outlet  
Maximum 5A per power  
outlet  
Belgium and  
France:  
TS-1FR (80-001399)  
Israel:  
TS-1IL (80-001799)  
100-240V AC, 50/60Hz, 5A  
220V AC, 50/60Hz, 5A  
Maximum 5A per power  
outlet  
Maximum 5A per power  
outlet  
South Africa  
TS-1ZA (80-001699)  
100-240V AC, 50/60Hz, 5A  
Maximum 5A per power  
outlet  
6
TBUS-6xl - Your TBUS-6xl Enclosure  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4  
Power Cord Options  
You can order any of the following power cords to use with a modular TBUS:  
Power Cord Type  
6ft/110V (North America)  
6ft/125V (Japan)  
Description  
P/N  
C-AC/US (110V)  
C-AC/JP (125V)  
C-AC/EU (220V)  
C-AC/IL (220V)  
C-AC/UK (250V)  
C-AC/IN (250V)  
C-AC/CN (250V)  
C-AC/ZA (250V)  
91-000099  
91-000699  
91-000199  
91-000999  
91-000299  
91-001099  
91-001199  
91-001299  
6ft/220V (Europe)  
6ft/220V (Israel)  
6ft/250V (UK)  
6ft/250V (India)  
6ft/250V/10A (China)  
6ft/250V/10A (South Africa)  
TBUS-6xl - Your TBUS-6xl Enclosure  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5
Installing the TBUS-6xl  
To install the TBUS-6xl perform the following steps:  
1. Assemble the inner frame (see Section 5.1).  
2. Install the inner frame (see Section 5.2).  
3. Cut an opening in the table (see Section 5.3).  
4. Insert the unit through the opening and secure to the table (see Section 5.4).  
5. Connect the cables (see Section 5.5).  
6. Insert pass-through cables (see Section 5.6)  
7. Adjust the height of the inner frame (see Section 5.7).  
5.1  
Assembling the Inner Frame  
The modules mounted on the inner frame can include single inserts and/or dual  
inserts as well as a power socket (in some models). This section describes how to  
assemble these modules.  
Each module kit comes with detailed assembly instructions.  
i
5.1.1  
Mounting the Inserts  
You can rearrange or remove any of the plates mounted on the inner frame and  
replace them with Kramer passive wall plates or connector modules for interfacing  
A/V type signals.  
To mount a Kramer insert or connector module:  
1. Unscrew the two screws that fasten the blank plate to the inner frame and  
remove the blank plate.  
2. Place the required Kramer insert over the opening, insert the two screws to  
fix the Kramer insert in place, and tighten them.  
8
TBUS-6xl - Installing the TBUS-6xl  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Figure 2: TBUS-6xl Inner Frame (P/N: 80-004499)  
#
Feature  
Function  
1
2
3
Power Socket Opening  
Suitable for a single power socket or the optional insert kit  
for TBUS  
Blank Plates  
Three blank covers that can be replaced with wall plates  
as required  
Adjustable Height Screw For adjusting the height of the Inner frame  
Holes  
5.1.2  
Mounting the Power Socket Assemblies  
To mount the power socket, place the power socket under the frame in its  
appropriate place and tighten with the two screws (supplied).  
Power socket kits come with assembly instructions.  
i
TBUS-6xl - Installing the TBUS-6xl  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5.1.3  
Installing a MegaTOOL  
To install a MegaTOOL, as shown in Figure 3:  
1. Screw the supplied spacers to their designated places (one on each side).  
2. Insert the MegaTOOL, from beneath, through the MegaTOOL opening.  
3. Screw the screws (one on each side) through the frame holes and spacers.  
Figure 3: Installing the MegaTOOL  
5.2  
Installing the Inner Frame  
To install the inner frame:  
1. Place the inner frame inside the TBUS-6xl enclosure.  
2. Set the required height using your fingers to bring the inner frame to the  
desired position, screw and tighten it in place using the height adjustment  
screws (supplied with the inner frame).  
Inner frame kits come with assembly instructions.  
i
10  
TBUS-6xl - Installing the TBUS-6xl  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5.3  
Cutting an Opening in the Table  
To cut an opening in the table:  
1. Place the cut out template (that is included with your TBUS-6xl) on the  
surface of the table exactly where you want to install the TBUS-6xl.  
2. Attach the template to the table with the included screws (if using the cut out  
template).  
3. Following the inside edge of the template, cut a hole in the table surface  
with a sabre or keyhole saw according to the dimensions shown in Figure 4  
(not to scale).  
The thickness of the table should be 76.2mm / 3 inches or less.  
i
123+2mm  
225+2mm  
Figure 4: Cut out Dimensions  
4. Unscrew and remove the template from the surface of the table and clean  
the table surface.  
Take care not to damage the table.  
If needed, you can download a full-scale template from our Web site.  
Kramer Electronics is not responsible for any damage caused to the  
table.  
!
TBUS-6xl - Installing the TBUS-6xl  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5.4  
Inserting the TBUS-6xl through the Cut Out Opening  
To install TBUS-6xl in the opening:  
1. Remove the protective rubber guard from around the outer rim of the  
TBUS-6xl housing. Beware of the sharp edge!  
2. Carefully insert the unit into the prepared opening (see Figure 5).  
3. Take the support brackets under the table and place them into the support  
bracket grooves on both sides of the unit (see Figure 1).  
4. Verify proper alignment of the unit before tightening the mounting screws.  
5. Tighten both mounting butterfly screws upward until they reach the table  
surface (from underneath). Tighten firmly (see Figure 5).  
6. Tighten the locking butterfly screws downward until tight against the  
mounting bracket.  
Figure 5: Inserting TBUS-6xl into the Prepared Opening  
12  
TBUS-6xl - Installing the TBUS-6xl  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5.5  
Connecting the Cables  
When replacing blank inserts with connector inserts (for example, VGA, audio,  
HDMI and so on):  
1. Insert the cables to their appropriate connectors from underneath.  
2. Secure the cables to the tie holes using the included self-locking ties.  
Do not secure the cables too tightly or too loosely. Leave a small amount of  
slack.  
After the TBUS-6xl is connected to mains power and the proper cables, it is ready for  
use.  
5.6  
Inserting Pass-through Cables  
When replacing inserts with the pass-through insert, for example, to connect a  
laptop, do the following:  
1. Remove the two screws attaching the split pass-through bracket.  
2. Remove the split grommet.  
3. Insert the cable through the rectangular opening.  
4. Open the split grommet slightly and insert the required cables.  
5. Place the split bracket around the grommet and position this assembly over  
the Inner Frame.  
6. Place the two screws appropriately and tighten the split bracket together  
with the grommet and inserted cables to the inner frame.  
7. Insert the self-locking ties through the tie holes to secure the cables to the  
inside walls of the enclosure.  
TBUS-6xl - Installing the TBUS-6xl  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5.7  
Adjusting the Height of the Inner frame  
If needed, you can adjust the inner frame height to accommodate large or bulky  
cables. To adjust, perform the following:  
1. Remove the four height adjustment screws, while supporting the surface  
from underneath with your fingers.  
2. Raise or lower the inner frame to the required height, insert the screws, and  
tighten them in place.  
14  
TBUS-6xl - Installing the TBUS-6xl  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
Using the TBUS-6xl  
Once the TBUS-6xl is installed, you can easily customize it to suit your own  
requirements by plugging in the required A/V equipment, as illustrated in the  
Figure 6: TBUS-6xl Boardroom Installation  
TBUS-6xl - Using the TBUS-6xl  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
7
Technical Specifications of the Assembled  
TBUS-6xl  
POWER SOURCE  
(AC power limits):  
Power Socket Assemblies  
Universal  
100-240V AC, 50/60Hz, 5A  
Maximum 5A per power outlet  
Fully compatible with power plugs in the UK, India, Italy  
and Denmark, as well as with the 2-prong Europlug.  
Partially compatible (if the polarity is reversed) with plugs  
in China, Switzerland, Israel and the USA. The universal  
socket does not supply grounding to plugs in Central  
Europe and France (you should order country specific  
sockets instead).  
Not compatible with South African plugs.  
USA  
100-240V AC, 50/60Hz, 5A  
Maximum 5A per power outlet  
100-240V AC, 50/60Hz, 5A  
Maximum 5A per power outlet  
100-240V AC, 50/60Hz, 5A  
Maximum 5A per power outlet  
100-240V AC, 50/60Hz, 5A  
Maximum 5A per power outlet  
100-240V AC, 50/60Hz, 5A  
Maximum 5A per power outlet  
220V AC, 50/60Hz, 5A  
Germany and EU  
Belgium and France  
South Africa  
Australia  
Israel  
Maximum 5A per power outlet  
220V AC, 50/60Hz, 5A  
South Africa  
T 6.3A 250V  
Maximum 5A per power outlet  
FUSE RATING:  
OPERATING TEMPERATURE +5 to +45 Deg. Centigrade  
RANGE:  
OPERATING HUMIDITY  
RANGE:  
10 to 90% RHL, non-condensing  
STORAGE TEMPERATURE  
RANGE:  
-20 to +70Deg. C.  
STORAGE HUMIDITY RANGE: 5 to 95% RHL, non-condensing  
DIMENSIONS:  
Top plate: 243mm x 140.4mm (9.6" x 5.5") W, D  
Enclosure: 203mm x 102mm x 130mm (8.0" x 4.0" x 5.1")  
W, D, H  
WEIGHT:  
TBUS-6: 2.03kg (4.48lbs) approx.  
Table clamps: 0.25kg (0.6lbs)  
ACCESSORIES:  
OPTIONS:  
Power cord, four self-locking ties, template, template  
screws  
Inner frames, passive wall plates and interfaces, power  
socket kits, power cord  
Specifications are subject to change without notice at http://www.kramerelectronics.com  
16  
TBUS-6xl - Technical Specifications of the Assembled TBUS-6xl  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
TBUS-6xl  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For the latest information on our products and a list of Kramer distributors,  
visit our Web site where updates to this user manual may be found.  
We welcome your questions, comments, and feedback.  
SAFETY WARNING  
Disconnect the unit from the power  
supply before opening and servicing  
!
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Electric Pressure Cooker KD6C35 User Manual
Ingersoll Rand Fan 63539X User Manual
JVC Camcorder GR AX285 User Manual
JVC Camcorder LYT2473 002A User Manual
Karcher Pressure Washer K 5585 User Manual
Kenmore Oven 790 4788 User Manual
Kenwood Car Amplifier KAC 816 User Manual
Kidco Camping Equipment P202 User Manual
KitchenAid Washer KAWE977B User Manual
Kramer Electronics Stereo Receiver COBRA R500 2 User Manual