Kramer Electronics, Ltd.
USER MANUAL
Models:
TP-125, UXGA / Audio / Data Line Transmitter
TP-126, UXGA / Audio / Data Line Receiver
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
1
Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been
providing a world of unique, creative, and affordable solutions to the vast
range of problems that confront the video, audio, presentation, and
broadcasting professional on a daily basis. In recent years, we have
redesigned and upgraded most of our line, making the best even better! Our
1,000-plus different models now appear in 11 groups1 that are clearly
defined by function.
Thank you for purchasing the Kramer TOOLS TP-125, UXGA / Audio /
Data Line Transmitter, and/or TP-126, UXGA / Audio / Data Line Receiver,
which are ideal for:
ñ
ñ
Presentation and multimedia applications
Long range graphics distribution for schools, hospitals, security,
and stores
Each package includes the following items:
ñ
ñ
ñ
TP-125 or TP-126
Power adapter (12V DC Input)
This user manual2
2
Getting Started
We recommend that you:
ñ
Unpack the equipment carefully and save the original box and
packaging materials for possible future shipment
ñ
ñ
Review the contents of this user manual
Use Kramer high-performance high-resolution cables3
1 GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Matrix Switchers; GROUP 3: Control Systems; GROUP 4:
Format/Standards Converters; GROUP 5: Twisted-Pair Solutions; GROUP 6: Specialty AV Products; GROUP 7: Scan
Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and
Rack Adapters; GROUP 11: Sierra Products
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Getting Started
2.1 Quick Start
This quick start chart summarizes the basic setup and operation steps.
KRAMER: SIMPLE CREATIVE TECHNOLOGY
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
3
verview
The TP-125 and TP-126 are a high-performance twisted pair transmitter
and receiver for computer graphics video (including HDTV), unbalanced
stereo audio, and RS-232 control commands.
The TP-125 converts computer graphics video, unbalanced stereo analog
audio, and RS-232 control commands to a twisted pair signal, and the
TP-126 converts the twisted pair signal back into computer graphics video,
unbalanced stereo and S/PDIF digital audio, and RS-232 control signals.
Together the TP-125 and TP-126 form a computer graphics/audio line
transmitter/receiver system.
ore specifically, the products feature:
ñ
ñ
ñ
Resolution up to UXGA or 1920x1200
HDTV compatibility
Simultaneous unbalanced stereo and S/PDIF (24-bit 48kHz) audio
outputs (TP-126)
ñ
ñ
Level (gain) and EQ (peaking) controls (TP-126)
System range up to 100m (300ft)
This user manual describes the following Kramer TOOLS:
ñ
ñ
TP-125 UXGA / Audio / Data Line Transmitter, see section 4.1
TP-126 UXGA / Audio / Data Line Receiver, see section
This section describes:
ñ
Using shielded twisted pair (STP) / unshielded twisted pair (UTP),
see section 3.1
ñ
Recommendations for achieving the best performance, see section 3.2
3.1 Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP)
The decision whether to use shielded twisted pair (STP) cable or unshielded
twisted pair (UTP) cable depends on the nature of the application.
In applications with high interference, shielded twisted pair (STP) cable is
recommended. However, the cable shield creates a capacitance that
degrades the frequency response of the device. For distances of 50 meters or
less shielded twisted pair (STP) cable is preferred because it provides
interference protection without any apparent degradation.
In applications where either: 1) the source and transmitter or receiver and
destination monitor are disconnected from common ground, or 2) the source
area (building) and destination area have no common ground – STP cable is
preferred. For long-range applications, unshielded twisted pair (UTP) cable
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Your TP-125 / TP-126
is preferred. However, unshielded twisted pair (UTP) cable should be
installed far away from sources of electromagnetic interference such as
electric cables and motors.
It is recommended to use shielded twisted pair (STP) skew-free Kramer cable
BC-SXTP for transmitting VGA signals, and shielded twisted pair (STP)
non-skew-free Kramer BC-STP cable for digital signals.
3.2 Recommendations for Achieving the Best Performance
To achieve the best performance:
ñ
Use only good quality connection cables1 to avoid interference,
deterioration in signal quality due to poor matching, and elevated
noise levels (often associated with low-quality cables)
ñ
Avoid interference from neighboring electrical appliances that
may adversely influence signal quality and position your Kramer
TP-125/TP-126 away from moisture, excessive sunlight and dust
Caution – No operator-serviceable parts inside unit.
Warning – Use only the Kramer Electronics input power
wall adapter that is provided with this unit2.
Warning – Disconnect power and unplug unit from wall
before installing or removing device or servicing unit.
4
Your TP-125 / TP-126
This section defines the:
ñ
ñ
TP-125, UXGA / Audio / Data Line Transmitter (see section 4.1)
TP-126, UXGA / Audio / Data Line Receiver (see section
)
2 For example: model number AD2512C, part number 2535-000251
KRAMER: SIMPLE CREATIVE TECHNOLOGY
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Your TP-125 / TP-126
4.1 Your TP-125 UXGA / Audio / Data Line Transmitter
The TP-125 is a high-performance transmitter that accepts:
ñ
ñ
ñ
A computer graphics input signal
An unbalanced stereo analog audio signal
RS-232 control commands
The TP-125 codes the signals and transmits them over CAT 5 cable to a
TP-126 receiver. The stereo analog audio signal is converted to the digital
audio (S/PDIF) stream before transmitting, thus preserving the quality of
the audio source signals. Commands and data can flow in both directions
via the RS-232 interface, allowing status requests and control of the
destination unit.
Figure 1 and Table 1 define the TP-125:
Figure 1: TP-125 UXGA / Audio / Data Line Transmitter
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Your TP-125 / TP-126
Table 1: TP-125 UXGA / Audio / Data Line Transmitter Features
#
Feature
Function
1
2
3
4
12V DC
AUDIO IN 3.5mm Mini Jack
RS-232 Terminal Block Connector
LINE OUT RJ-45 Connector
+12V DC connector for powering the unit
Connects to the audio source
Connects to the PC or the Remote Controller (see section 5.1)
Connects to the LINE IN RJ-45 connector on the TP-126
UXGA / Audio Line Receiver
5
6
UXGA IN 15-pin HD (F) Connector
ON LED
Connect to the UXGA source
Illuminates when receiving power
4.1.1 The TP-125 Internal Polarity Switches
Figure 2 and Table 2 define the internal sync polarity switches inside the
TP-125.
Note, that you need to open the TP-125 unit to gain access to the Vs and Hs
Polarity switches. After setting the switches, close the TP-125 unit.
Figure 2: TP-125 Internal Polarity Switches
Table 2: Features of the TP-125 Internal Polarity Switches
Feature
VS Switch
Function
Slide down to set the V SYNC to negative polarity (NEG);
slide up1 to set the V SYNC to positive polarity (NORM)
HS Switch
Slide down to set the H SYNC to negative polarity (NEG);
slide up1 to set the H SYNC to positive polarity (NORM)
1 By default, both switches are set down (for a negative V SYNC and H SYNC polarity)
KRAMER: SIMPLE CREATIVE TECHNOLOGY
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Your TP-125 / TP-126
4.2 Your TP-126 UXGA / Audio / Data Line Receiver
The TP-126 is a high-performance receiver obtaining the computer graphics
signal/audio/control data from the Kramer TP-125 via UTP cabling at its
CAT 5 line input. The TP-126 outputs a computer graphics signal, an
unbalanced stereo analog audio signal, a converted digital audio (S/PDIF)
signal, and bi-directional RS-232 control commands and data, to and from the
receiver. The RS-232 interface makes it possible to control virtually any
device over a transmission range of more than 300 feet (more than 100
meters) over UTP cabling. In addition, the TP-126 features:
ñ
ñ
ñ
ñ
Level and EQ. control for the UXGA signals
The capability to change the polarity of decoding H and V Sync
24 bit 48kHz S/PDIF digital audio that supplies the highest quality audio
12V DC power
Figure 3 and Table 3 define the TP-126 UXGA / Audio / Data Line Receiver:
Figure 3: TP-126 UXGA / Audio / Data Line Receiver (Top, Front, and Rear)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Your TP-125 / TP-126
Table 3: TP-126 UXGA / Audio / Data Line Receiver (Top, Front, and Rear) Features
#
Feature
Function
+12V DC connector for powering the unit
Connects to the digital audio acceptor
Connects to the analog audio acceptor
1
2
3
12V DC
S/PDIF RCA connector
ANALOG 3.5mm Mini Jack
4
5
6
7
8
9
RS-232 Terminal Block Connector
LINE IN RJ-45 Connector
UXGA OUT 15-pin HD (F) Connector Connects to the UXGA acceptor
Connects to the controlled unit
Connects to1 the LINE OUT RJ-45 connector on the TP-125
ON LED
Illuminates when receiving power
Adjusts the cable compensation equalization level
Adjusts the output signal level
EQ.2 Trimmer
LEVEL Trimmer
LINK LED
10
Illuminates when receiving the correct input signal
4.2.1 Your TP-126 UXGA / Audio / Data Line Receiver (Underside)
Figure 4 and Table 4 define the underside of the TP-126 UXGA / Audio /
Data Line Receiver. Note, that you need to open the TP-126 unit to gain
access to the Vs and Hs Polarity switches. After setting the switches, close
the TP-126 unit.
Figure 4: TP-126 UXGA / Audio / Data Line Receiver (Underside)
Table 4: TP-126 UXGA / Audio / Data Line Receiver (Underside) Features
#
1
Feature
VS Switch
Function
Slide down to set the V SYNC to negative polarity (NEG);
slide up1 to set the V SYNC to positive polarity (NORM)
2
HS Switch
Slide down to set the H SYNC to negative polarity (NEG);
slide up1 to set the H SYNC to positive polarity (NORM)
1 Using a UTP cable with CAT 5 connectors at both ends (the PINOUT is defined in Figure 7 and Table 6)
2 Degradation and UXGA signal loss can result from using long cables (due to stray capacitance), sometimes leading to a
total loss of sharpness in high-resolution signals
KRAMER: SIMPLE CREATIVE TECHNOLOGY
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the TP-125/TP-126 Transmitter/Receiver Pair
5
Connecting the TP-125/TP-126 Transmitter/Receiver Pair
You can use the TP-125 UXGA / Audio / Data Line Transmitter and the
TP-126 UXGA / Audio / Data Line Receiver to configure a twisted pair
transmitter and receiver system, to transmit the video, audio and RS-232 control
signals via CAT 5 UTP cable.
To connect the TP-125 and the TP-126 to create a twisted pair transmitter and
receiver system, as the example in Figure 5 illustrates, do the following:
1. On the TP-125, connect:
°
An UXGA source (for example, the graphics card on a laptop) to
the UXGA IN 15-pin HD (F) connector and an audio source to
the Audio IN 3.5mm mini jack, for example, using a Kramer
C-GMA/GMA cable (VGA 15-pin HD (M) +Audio jack to VGA
15-pin HD (M) +Audio jack)2
°
An RS-232 cable with a 9-pin D-sub connector at one end to the
laptop, and a 3 PIN terminal block connector at the other end to
the TP-125 RS-232 port3
2. On the TP-126, connect:
°
The UXGA OUT 15-pin HD (F) connector to the AV display
system
°
The S/PDIF Audio OUT RCA connector to a digital AV
Receiver (leave the ANALOG Audio OUT 3.5mm mini jack
unconnected)
°
An RS-232 cable with a 3 PIN terminal block connector at one
end to the TP-126 RS-232 port3, and a 9-PIN D-SUB connector
at the other end to the RS-232 port on the AV display system
3. Connect the Line OUT RJ-45 connector on the TP-125 to the LINE IN
RJ-45 connector on the TP-126, via UTP cabling4 (with a range of more
than 300ft (>100m)).
4. Connect the 12V DC power supply to the power socket and connect the
adapter to the mains electricity on both the TP-125 and the TP-126.
5. On the TP-126:
°
Adjust the video output signal level and/or cable compensation
equalization level with a screwdriver, if required
1 By default, both switches are set down (for a negative V SYNC and H SYNC polarity)
connect an UXGA source to the UXGA IN 15-pin HD (F) connector, and a separate audio source to the AUDIO IN 3.5mm
mini jack
3 As defined in Figure 6 and Table 5
4 For details of how to wire a CAT 5 LINE IN / LINE OUT RJ-45 connector, see section 5.2
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the TP-125/TP-126 Transmitter/Receiver Pair
°
If necessary, set the H SYNC and V SYNC switches1, on the
underside
Figure 5: Connecting the UXGA / Audio / Data Line Transmitter / Receiver System
1 By default, both switches are set down (for negative V SYNC and H SYNC polarity)
KRAMER: SIMPLE CREATIVE TECHNOLOGY
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the TP-125/TP-126 Transmitter/Receiver Pair
5.1 Transmitting via RS-232 (for example, using a PC)
Prepare an RS-232 cable with a 9-pin D-sub connector at one end, and a 3
PIN terminal block connector at the other end, as defined in Table 5 and
Figure 6:
Table 5: RS-232 PINOUT
Connection
Connect this PIN on To this PIN on the
the Terminal Block
Connector:
9-pin D-sub
Connector
TxD
RxD
GND
PIN 2
PIN 3
PIN 5
Figure 6: RS-232 PINOUT
Connection
5.2 Wiring the CAT 5 RJ-45 Connectors
Table 6 and Figure 7 define the CAT 5 pinout, using a straight pin-to-pin
cable with RJ-45 connectors:
Table 6: CAT 5 Connector Pinout
EIA /TIA 568A
EIA /TIA 568B
PIN
1
Wire Color
Green / White
Green
PIN
1
Wire Color
Orange / White
Orange
2
2
3
Orange / White
Blue
3
Green / White
Blue
4
4
5
Blue / White
Orange
5
Blue / White
Green
6
6
7
Brown / White
Brown
7
Brown / White
Brown
8
8
Pair 1 4 and 5
Pair 2 3 and 6
Pair 3 1 and 2
Pair 4 7 and 8
Pair 1 4 and 5
Pair 2 1 and 2
Pair 3 3 and 6
Pair 4 7 and 8
Figure 7: CAT 5 Connector
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Specifications
6
Technical Specifications
The TP-125, TP-126 technical specifications are shown in Table 7:
Table 7: Technical Specifications of the TP-125 / TP-126
TP-125
TP-126
INPUTS:
Video: 1 UXGA on an HD15 connector
1 RJ-45 LINE IN connector
Audio: 1 audio ANALOG 3.5mm mini jack
OUTPUTS:
1 RJ-45 OUT connector
Video: 1 UXGA on an HD15 connector
Audio:
1 audio S/PDIF RCA connector
1 audio ANALOG 3.5mm mini jack
RESOLUTION:
MAX. OUTPUT LEVEL:
Up to UXGA or 1920x1200
RS-232 3 PIN Terminal Block
Video: 1.6V
Audio: 2.3V
RS-232 3 PIN Terminal Block
Level: –7.5dB to +4.4dB,
EQ.: 0dB to +33dBm (130m) @ 50MHz
CONTROLS:
RS-232 BAUD RATE:
RS-232 MODE:
BANDWIDTH:
S/N RATIO:
Up to 19200kbps
Full-duplex
Audio: 20Hz – [email protected]
Audio: <–80dB
TOTAL GAIN:
Audio:
Analog/analog: 0dB
Analog/SPDIF: –12dBFS
COUPLING:
TND+N:
POWER SOURCE:
DIMENSIONS:
WEIGHT:
AC
Audio: <0.01%
12 VDC 60mA
12.1cm x 7.18cm x 2.42cm (4.76" x 2.83" x 0.95"), W, D, H
0.3 kg. (0.67 lbs.) approx.
ACCESSORIES:
Power supply
KRAMER: SIMPLE CREATIVE TECHNOLOGY
12
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
For the latest information on our products and a list of Kramer
where updates to this user manual may be found.
We welcome your questions, comments and feedback.
Safety Warning:
Disconnect the unit from the power supply before
opening/servicing.
Caution
2900- 000371
4
P/N:
Rev:
Kramer Electronics, Ltd.
E-mail: [email protected]
P/N: 2900-000371 REV 4
Download from Www.Somanuals.com. All Manuals Search And Download.
|