Kramer Electronics, Ltd.
Kramer Control Systems
Virtual Device
Build Guidelines
Revision 1
Intended for Kramer Technical Personnel or external System Integrators.
To check that you have the latest version, go to the DOWNLOADS section of our Web site at:
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
1
Introduction
Kramer Electronics offers a wide variety of control products that meet numerous different AV
requirements. These solutions make up the Kramer control system and offer seamless compatibility
with Kramer signal management and scaling products, as well as interfacing with display devices
and other third party products for complete room control solutions.
The control action lists (macros), associated in the K-Config configuration application with various
physical (keypad controllers) and software triggers, can also be initiated by sending the Kramer
Protocol 3000 commands over IP.
This document serves as a guideline for building an application (referred to as the "Virtual Device"
in K-Config and in this document) that will serve as a User Interface device in a Kramer based
room control system.
The application can run on any platform (mobile, PC, and so on) and under any OS (Windows®,
Linux®, Android™, iOS®, and so on) - according to the competence of the developer, and end-user
preference.
The developer can use "Virtual Device" development guidelines to create the application for the
Virtual Device without any limitation of platform, design, and so on.
This document is intended for competent developers under the relevant OS and for the relevant
devices.
1.1 Definitions (within the context of this document)
K-NET™ setup – A Kramer control setup, made from at least two units (one of them, the User
Interface device, can be a Virtual Device). The K-NET units communicate between them using the
Kramer Protocol 3000. Each unit on the K-NET setup has its own unique K-NET ID number.
Master Room Controller (Master RC) – A Kramer room control device; used as the Master in a
K-NET room control installation.
The Master RC will have a K-NET ID of 1 and will run the relevant configuration file created in the
K-Config application.
As of February 2011, Kramer's applicable Master RCs for Virtual Device setups are – SV-551,
SV-552, SL-1, SL-10, SL-12 and SL-14RC.
K-NET auxiliary device – A Kramer K-NET device, which is part of a Kramer room control setup
and is connected with a K-NET cable to the Master RC.
The auxiliary device K-NET ID will always be greater than 1.
Virtual Device – An application simulating a User Interface device that communicates over IP,
with a single Kramer Master RC as part of the K-NET setup.
The Virtual Device will use one of two reserved K-NET ID numbers – 11 or 12.
K-Config Virtual Device triggers layer – A functional duplication of the Virtual Device active
buttons and text fields in the K-Config application. Used to link the Virtual Device screens to the
control action lists (macros) written under K-Config.
2
The Communication Layer
for communication with the associated Master RC.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
The Virtual Device – an Application Example
The Virtual Device – an Application Example
The following sections define the general guidelines for building a Virtual Device.
3
3.1 System Overview
• Satellite TV set top box (video and audio on an HDMI output)
Sources
• DVD player (video on a CV output with analog stereo audio)
• PC or laptop (PC Graphics on a 15-pin HD output with analog stereo
audio)
A Display Device Flat panel LCD
A Master RC
SV-552 SummitView™ Processor Switcher
All the sources transmit video and audio to the SV-552 (using Kramer SV-30X wall plates) which
outputs the video signals to the flat panel LCD and the amplified audio to a pair of ceiling speakers.
In this setup example, an iPhone® or an Android running cell phone is used as a user interface that
Figure 1: An Application Example
2
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Download from Www.Somanuals.com. All Manuals Search And Download.
The Virtual Device – an Application Example
3.2 Hardware Setup
(iPhone/iPad®/Android) and the Kramer Master RC (SV-552 in this example).
Both the Master RC and the Mobile Device should use the same net/sub-net range. The Master RC
(SV-552 in this example) will use wired connection to the relevant IT network while the mobile
device will be connected to the same network wirelessly, so a wireless router or access point will
Figure 2: The Physical Connection
3.3 Implementation
The Kramer Master Room Controllers use Protocol 3000 to interact with several K-NET auxiliary
communicate with the Kramer Master RC and the Master RC will communicate (usually via
RS-232, IR or other common control protocols) with the AV products used in the room.
Each trigger button or icon used in the Virtual Device should be functionally duplicated in the
K-Config Virtual Device triggers layer.
The layout and size of buttons and text fields on the triggers layer, as seen on the graphical layout
shown on K-Config, has no real importance. The only thing to note is the ID number of each
functional button – enabling the developer to address each one of them in the Virtual Device
application and by that trigger the required control action list.
From the above it should be clear that the Virtual Device application design, look-and-feel, style or
any other property are not limited in any way and only depend on the user needs and capabilities.
1 User Datagram Protocol
3
Download from Www.Somanuals.com. All Manuals Search And Download.
The Virtual Device – an Application Example
3.3.1 A Setup Example
• A MAIN MENU screen
• A SETTINGS screen
• A VIRTUAL DEVICE (source switching) screen
The first two screens are used to set and enter the VIRTUAL DEVICE screen (the third screen).
The VIRTUAL DEVICE screen is duplicated in the K-Config Virtual Device triggers layer.
Figure 3: Application Screen Examples
The MAIN MENU Screen
The MAIN MENU screen includes three buttons:
• SETTINGS to enter the Settings screen
• VIRTUAL DEVICE to enter the virtual device screen
• EXIT to exit the application
All three buttons are related to internal functions or procedures in the Virtual Device application;
therefore they are not duplicated in the K-Config Virtual Device triggers layer.
The SETTINGS Screen
The SETTINGS screen lets you configure the communication setting with the Master RC and
includes three buttons as well:
• IP (as an option) to manually configure the IP Address of the Master RC
• K-ID to enter the K-NET ID of the Virtual Device application
• CONNECT to connect to the Master RC
This manual connection approach is useful if the same Virtual Device application is to run on the
same physical device as a user interface for several K-NET rooms (several Master RCs).
In most cases, the end-user should not be able to easily change the IP settings and especially the
K-NET ID of the Virtual Devices, since changing these settings will result in loss of
communication with the Master RC.
This screen is also not duplicated on the K-Config Virtual Device triggers layer.
4
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Download from Www.Somanuals.com. All Manuals Search And Download.
The Virtual Device – an Application Example
The VIRTUAL DEVICE Screen
The Virtual Device screen includes three buttons that trigger the switching of a switcher, scaler or a
This screen is duplicated as the Virtual Device in the K-Config Virtual Device triggers layer.
Figure 4: Virtual Device Buttons and Label
K-Config software is used to write the control action list to the K-Config Virtual Device triggers
layer; and once the end user presses a button on the Virtual Device, this list of actions is executed.
3.4 Functionalities
The following sections describe how to:
3.4.1 Establishing a Connection to the Master RC
The Virtual Device can be connected to the Master RC in various ways.
K-NET ID, after which the CONNECT button is pressed to establish a connection with the Master
RC.
Alternatively, this handshaking procedure can be executed automatically by the application upon
startup or within any other developer-defined event.
In any case, the connect procedure opens the UDP connection and once a connection is established
#\r
1 Many room setups will also need to switch the input channel of the display device in the room
5
Download from Www.Somanuals.com. All Manuals Search And Download.
The Virtual Device – an Application Example
The Virtual Device application then waits for a response from the Master RC for a predefined time
Figure 5: Connecting the Virtual Device to the Room Controller
6
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Download from Www.Somanuals.com. All Manuals Search And Download.
The Virtual Device – an Application Example
Once an "OK" response is received from the Master RC, the connection is established, see Figure 6
Figure 6: Connecting Flow Chart
7
Download from Www.Somanuals.com. All Manuals Search And Download.
The Virtual Device – an Application Example
3.4.2 Sending and receiving Data to/from Master RC
The Master RC broadcasts its outgoing Protocol 3000 messages on the K-NET bus. All its data
messages are sent to all the K-NET devices that are connected to it. Each K-NET Auxiliary Device
should execute only commands that match its K-NET ID. All the Other commands must be ignored,
Depending on the Master RC in use, up to two Virtual Devices with reserved K-NET ID of 11
and 12 can be used.
The K-Net ID of a Virtual Device is defined in K-Config as a property of the K-Config Virtual
Device triggers layer.
Figure 7: Receiving data from the Room Controller Flow Chart
8
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Download from Www.Somanuals.com. All Manuals Search And Download.
The Virtual Device – an Application Example
The number of buttons on the Virtual Device and their functionalities are defined using the
K-Config software in K-Config Virtual Device triggers layer.
Pressing a "button" on a Virtual Device application will send a corresponding command to the
Master RC.
In the following example, the Virtual Device has K-NET ID = 11 and pressing the first button (#1
in the defined K-Config Virtual Device trigger layer) of the Virtual Device executes the following
actions:
• The button color changes to red
• The text label (a defined text field) changes to PC SELECTED
• The SV-552 switches to the VGA input
The command sent from the virtual device is:
#BTN 1,11,R\r
// Sent command from Virtual Device application
The answer from the Master RC to this event, as defined for Button 1 of the Virtual Device with
K-NET ID=11 in K-Config, is:
#11@RGB 1,255,0,0,1
#11@LABEL 1,"ON"
// Set RED Color on Virtual Device
// Set Label "PC SELECTED" on Virtual Device
#... (some others commands)
~01@BTN 1,11,R OK
// ACK for command from Master RC
The application catches the answer and changes the button color to "RED" and the label to "PC
9
Download from Www.Somanuals.com. All Manuals Search And Download.
The Virtual Device – an Application Example
Figure 8: Sending and Receiving Commands
Important – The Master RC can send mostly button status/lighting and text field commands to its K-
Net Aux devices. However, the competent developer can easily use a combination of virtual buttons
defined as a property of the Virtual Device in K-Config and use these messages as global variables
and other powerful options to enable application flexibility.
For example, Button #15 in Virtual Device #12 is not seen on the Virtual Device application.
Instead, its color status is changed as part of the K-Config action lists and it is used a global
variable. The Virtual Device application will check it when needed (If BTN15=BLUE then…., If
BTN15=RED then…).
10
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Download from Www.Somanuals.com. All Manuals Search And Download.
Communication Protocol 3000
Communication Protocol 3000
4
= Carriage return (ASCII 13 = 0x0D)
= Line feed (ASCII 10 = 0x0A)
= Space (ASCII 32 = 0x20)
4.1 Host message format
start
Address (optional)
body
delimiter
Destination_id@
#
message
4.1.1 Simple command
(Commands string with only one command without addressing):
start
#
body
delimiter
delimiter
Command SP Parameter_1,Parameter_2,…
Device message format:
start
Address (optional)
body
Sender_id@
~
message
4.1.2 Device long response (Echoing command)
start
~
Address (optional)
body
command SP [param1 ,param2 …]result
delimiter
Sender_id@
4.2 Command parts details
Command:
Sequence of ASCII letters ('A'-'Z', 'a'-'z' and '-').
Command will be separated from parameters with at least single space.
Parameters:
Sequence of Alfa-Numeric ASCII chars ('0'-'9','A'-'Z','a'-'z' and some special chars for specific
commands), parameters will be separated by commas.
Message string:
Every command must be entered as part of a message string that begins with message starting
char and ends with message closing char. Note that string can contain more than one command
separated by pipe ("|") char.
Message starting char:
'#' for host command\query.
'~' for machine response.
Device address:
K_Net Device ID followed by '@' char.
Query sign = '?', will follow after some commands to define query request.
Message closing char =
Host messages - Carriage Return (ASCII 13), will be referred to by
in this document.
Machine messages - Carriage Return (ASCII 13) + Line-Feed (ASCII 10), will be referred to by
Spaces between parameters or command parts will be ignored.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Communication Protocol 3000
4.3 Commands Entering
If a terminal software is used to connect over serial \ ethernet \ USB port, it is possible to directly
enter all commands characters ( will be entered by Enter key, that key sends also , but this
char will be ignored by commands parser).
Sending commands from 3rd party controllers requires the coding of some characters in a special
form (such as \X##). With most 3rd party units there is a way to enter all ASCII characters so it is
possible to send all the commands also from the controller.
4.4 Commands Forms
Some commands have a short name syntax beside the full name to allow faster typing, response is
always in long syntax.
4.5 Input String Max Length
64 characters.
General Commands
Command
Syntax
Response
Protocol Handshaking
#DEV_ID@
~ DEV_ID@ OK
Parameters:
DEV_ID – Each device has its own K-Net ID that matches to a specific device in K-Config configuration tree.
K-Net Auxiliary Device must react only to commands which are preceded by its own ID.
Example:
WebAccess:
#03@
Device Application: ~03@ OK
Note:
Every device (or application that emulates a device) should reply to this request if preceded by its K-Net ID.
Room controllers commands
Emulate button action
#01@BTN BTN,[KEYPAD_ID,[ACTION ]]CR
~01@BTN BTN,KEYPAD_ID,ACTION
RESULTCRLF
Device needs to send this command to the master device when it wants to emulate button action
BTN – Button ID according to the configuration in K-Config
KEYPAD_ID – The KNET ID of the device that the emulated button belongs to according to the configuration in K-Config
ACTION - P=Button Pressing / H= Button Holding / R=Button Release.
Valid button operations sequence will be P->H(->H…)->R or P->R or only R.
Pressing and Holding will activate “Activate while pressed” trigger if defined in K-Config, Releasing will activate “Activate on Release” and “Toggle”
triggers.
RESULT – OK
User can supply 1, 2 or 3 arguments.
The default arguments are :
KEYPAD_ID - the first ID on the list (in the file portdef.ini)
ACTION – P=Button Pressing / R=Button Release.
Example (device application emulate releasing of button 1 in keypad 3):
Device Application: #01@BTN 1,3,RCR
Master response:
~01@BTN 1,3,R OKCRLF
Note: Master response may be followed by other commands or replies according to the Action list for the button trigger from configuration in K-Config.
Config RGB button leds
#DEV_ID@RGB BTN, RED, GREEN, BLUE, STATECR
~DEV_ID@RGB BTN, RED, GREEN, BLUE,
STATE RESULT CRLF
Device that implements lit buttons should react to this command and set its button.
Device can support full color buttons or just plain on/off lights.
12
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Download from Www.Somanuals.com. All Manuals Search And Download.
Communication Protocol 3000
BTN - Button ID according to the configuration in K-Config
RED, GREEN, BLUE- Color intensity for each base color. Values are from 0 (No color) to 255 (Full color). Plain buttons that support only on/off light
should ignore values of these parameters (except if all set to zero – same as turning light off).
STATE :
"0" or "Off" (Color parameters can be ignored).
"1" or "On"
"2" or "Slow" for slow blink
"3" or "Fast" for fast blink
RESULT – OK if command has been executed.
“#DEV_ID@RGB ERR 003” should be returned if any parameter exceeds its limits (for example – Button ID does not exist).
Example:
Master Device:
#03@RGB 1,0,255,0,1CR
Result: Device Application needs to light on its button 1 and set color to Full green.
Device Application response: ~03@RGB 1,0,255,0,1 OKCRLF
Get RGB button leds configuration
#DEV_ID@RGB? BTNCR
~DEV_ID@RGB
BTN,RED,GREEN,BLUE,STATE CRLF
Device that implements lit buttons should reply this request and give its button color and state. Device can support full color buttons or just plain on/off
lights.
BTN - Button ID according to the configuration in K-Config
RED, GREEN, BLUE- Color intensity for each base color. Values are from 0 (No color) to 255 (Full color). Plain buttons that support only on/off light can
set these parameters to any value (except if all are set to zero – same as turning light off).
STATE =
"0" or "Off" (Values of color parameters doesn’t matter).
"1" or "On"
"2" or "Slow" for slow blink
"3" or "Fast" for fast blink
Example:
Master Device:
#03@RGB? 1CR
Device Application response: ~03@RGB 1,0,255,0,1CRLF
Write text to LCD
#DEV_ID@LCD LCD_ID,”TEXT”CR
~DEV_ID@LCD LCD_ID,”TEXT”
RESULTCRLF
Device that implements label (LCD) should react to this command and set its “LCD” (or text label).
LCD_ID – Label (LCD) ID according to the configuration in K-Config
TEXT – The text to display in the label (This parameter should be enclosed by quotation marks, character 34 in Ascii)
RESULT – OK if command has been executed.
“LCD ERR 003” should return if any parameter exceeds its limits (for example – LCD with this ID doesn’t exist).
Read text from LCD
#DEV_ID@LCD? LCD_IDCR
~DEV_ID@LCD LCD_ID,”TEXT”CRLF
Device that implements label (LCD) should react to this command and set its “LCD” (or text label).
LCD_ID – Label (LCD) ID according to the configuration in K-Config
TEXT – The text to display in the label (This parameter should be enclosed by quotation marks, character 34 in Ascii)
Restore User Interface
#01@UI DEVICE_IDCR
~01@UI DEVICE_ID OKCRLF
After answering OK, the master will send to the device commands to refresh user interface elements like RGB buttons and LCD labels.
For example:
#DEV_ID@RGB 1, RED, GREEN, BLUE, STATECR
#DEV_ID@RGB 2, RED, GREEN, BLUE, STATECR
…(All RGB)
#DEV_ID@LCD 1,”TEXT”CR
#DEV_ID@LCD 2,”TEXT”CR
…(All LCD)
Use this command to get the current user interface state on program start or refreshing the GUI.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Communication Protocol 3000
Result codes (errors)
Syntax
No error. Command running succeeded
~DEV_ID@COMMAND PARAMETERS OKCRLF
Protocol Errors
Syntax Error (For example: Not enough parameters)
~DEV_ID@COMMAND ERR001CRLF
~DEV_ID@ ERR002CRLF
Command not available for this device
Parameter is out of range
~DEV_ID@COMMAND ERR003CRLF
~DEV_ID@COMMAND ERR004CRLF
Unauthorized access (running command without the matching login).
Security commands
Command
Syntax
Response
Read Security flag
SECUR?
SECUR ON/OFF
LOGIN AUTH RESULT
LOGIN AUTH
Login
LOGIN AUTH PASSWORD
LOGIN?
Get Login
Logout
LOGOUT
LOGOUT RESULT
AUTH = USER \ ADMIN.
ON/OFF
= "0" or "OFF"
"1" or "ON"
Login flow:
(Password and SECUR mode can be set from K-Config program).
1. Send SECUR? Command
2. If answer is SECUR OFF – no login needed.
3. If answer is SECUR ON – continue to login (step 4)
4. Send LOGIN USER, PASSWORD
5. Device will start to work normally.
6. If communication is not active for more than 5 minutes – UDP socket will be closed and device will logout automatically so you will
need to LOGIN again.
7. To eliminate automatic logout – you can send any command (for example Handshake) from time to time.
8. On program exit send LOGOUT (If not – device will automatically logout after timeout).
Password sessions:
Login with user or admin password will open a match session, so it is possible to continue entering commands without re-login until connection will
terminate.
For Ethernet connection, sessions will be opened while socket connection is live.
For Serial or USB connection, session will live until time-out will reach.
* To reset admin password you need to factory reset all the device data.
14