Knoll Systems Car Amplifier MVP44a User Manual

Specifications  
MVP44a 8 Channel Power Amplifier  
Inputs:  
4 pairs of gold RCA jacks  
Inputimpedance: 24 k ohms  
Outputs:  
Output power:  
Gold 5 way Binding posts  
50 watts RMS per channel (8 ohms)  
Peak output power: 100 watts RMS per channel (8 ohms)  
systems  
Ideal impedance:  
Freq. response:  
S/N ratio:  
THDdistortion:  
IMD distortion  
Trigger control:  
Power:  
6-8 ohms  
10 Hz - 40 kHz +/- 1 dB (1w)  
over 105 dB A weighted 50 watts  
<0.1% 20 Hz to 20 kHz  
<0.01% 60 Hz 7 kHz 4:1 (SMPTE)  
12VDC output 60mA max.  
750 watts 117 VAC  
MVP44a  
Dimensions:  
Weight:  
17" x 3.5" x 10.5"  
22 lbs (10 kg)  
Four stereo power amplifiers with  
individual volume control electronics  
and four input source selection  
OperatingTemp:  
-20C to +60C (-4F to +140F)  
Caution:Neverlistentosoundthatisdistorted.Ifdistortedsound  
isheard,turnthevolumedownimmediatelyorspeaker  
and/or amplifier damage could occur that is not covered by the  
warranty. If this problem persists, contact your dealer.  
INSTALLATION  
MANUAL  
It is very important to use a top quality  
RJ45 8/8 crimper tool. We strongly  
suggest using a cat 5 / RJ45 electronic  
tester to verify the wire conductors.  
Limited Warranty  
Knöll Systems warrants the its electronic products except projectors sold in Canada and the  
USA by authorized Knöll dealers to be free from defects in materials and workmanship. This  
warranty extends for three full years from the date of purchase by the consumer. Any  
products returned freight prepaid to Knöll Systems and found to be defective by Knöll  
Systems within the warranty period will be repaired or replaced at Knöll Systems option, at  
no charge. Knöll Systems will not be responsible for the actual cost of installation or removal  
of the product, nor for any consequential or incidental damages. Some states do not allow the  
exclusion or limitation of incidental or consequential damages, so the above limitation or  
exclusion may not apply to you. This warranty gives you specific legal rights. You may have  
additional rights which vary from state to state. Knöll products sold outside of Canada and  
the USA may be covered by warranties provided by an authorized Knöll distributor. Please  
contact the distributor in the country that the Knöll product was purchased.  
Printed in Canada  
Complies with part 15 of the FCC rules. Operation is subject to:  
1. This device may not cause harmful interference  
Knöll Systems, Richmond, BC & Point Roberts WA  
2. This device must accept any interference received  
including interference that may cause undesired operation.  
C
COPYRIGHT 1998-2003, Knöll Systems, All Rights Reserved  
Knöll Systems  
In America:  
145 Tyee Drive, #1206  
In Canada:  
11791 Machrina Way #120  
tel (604) 272-4555  
fax (604) 272-5595  
Point Roberts, WA 98281 Richmond, B.C. V7A 4V3  
Version 3.3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System layout considerations  
possible in the sequence to give the components settling time. For  
example, sequence a power-on command: CD on, tuner on, and CD  
play rather than CD on, CD play, and tuner ON.  
TheMVP44aistheheartofawholehomemusicsystem.AMVP44a  
is designed to work with 1-4 rooms or zones. Up to three MVP44a's  
canbegangedtogethertoallowupto12roomsorzoneseach  
individuallycontrollingoneortwopairsofenclosureorinwall  
speakers.Connectionisachievedviathedataportusingastereo  
3.5mm jack on the rear of the MVP44a.  
7. Make sure the PROGRAM lamp is on.  
8. Make sure the bank 1 switch is on and bank 2, 3 and 4 are off.  
9. Push the SEQ (sequence) button.  
10.Carefully touch (for one sec.) the wire to the bank 1 + terminal  
1 to 6 where the first sequence is to be stored.  
RoomsareusuallycontrolledbyaMR60keypad.Thekeypadsare  
notintentedforoutdooruse.TheMR60containsanalmostall  
brandinfraredrepeaterandmostfunctionscanbecontrolledbythe  
KnollRB8remotecontrol.RB8commandscaneasilybestoredina  
learningremote.TheMR60isavailablewiththreedifferentsource  
layouts(alloftheMR60keypadsinonesystemhavetohavethe  
samesourcelayout)andthreebezelcolorswhite,almondandivory  
foratotalof9models. Thesourcelayoutandbezelcolorsareeasyto  
changeinthefield.  
11. Move the bank 1 switch off and the bank 2 switch on.  
12. Touch the wire to the terminal where the first IR signal of the  
sequence is stored (for one second). Touch the wire to the  
terminal where the second IR signal of the sequence is stored  
(for one second). Touch any other terminals until the entire  
command sequence is stored.  
13. Push the SEQ button and then the PGM button to leave the  
program mode (lamp goes out).  
14. Move the bank 1 switch to on and bank 2, 3, and 4 to off.  
The sequence is now complete.  
15. Repeat steps 7 to 14 for each of the other sequences.  
SomeroomswillnotrequireaMR60keypadandmostMVP44a  
functions can be utilized with an RB8 remote and an infrared  
repeater (a MR173 IR converter is required). Up to three IR  
receiversinthreedifferentroomscanbeconnectedtoasingle  
MR173.TheMVP44aincludesaninternalfoursingleordualemitter  
connectionblock,soemitterswillhavetobeorderedifrequired. The  
infraredpassthroughisalwaysavailablewhentheamplifieristurned  
onandinstandbyorpoweredup.  
Note: 590-00 programming should be fully tested. Occasionally one  
source component gets out of sequence especially if IR remote  
controls are used (most often when using the remote to turn on and  
off source components). The system user should be shown how to  
correctforasourcecomponentgettingoutofsequence.  
Follow directions from the speaker manufacturers when deciding  
speaker locations.  
Note:The MVP44a prefers 6-8 ohm speaker loads. Connecting to  
4ohmloadswon'thurttheMVP44abutthosechannelsconnected  
to4ohmloadsmayoccasionallyshutdownduetooverloading.  
Never connect the MVP44a to 2 ohm loads.  
Caution:The MVP44a contains no user serviceable parts, so  
do not attempt to open or repair the MVP44a. Refer servicing to  
aqualifiedtechnicianonlyorcontactthefactoryforinformation.  
TheMVP44ahasacoolingfantoincreaselongtermpoweroutput  
and reliability.  
...continued  
3
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
...Systemlayoutconsiderationscontinued  
in bank 1 positions 1 through 6).  
The 590-00 can learn up to 16 different commands on each of its  
four banks. If more than 10 different IR commands are to be stored  
use bank 2, 3, and 4 to store the sequence commands and bank one  
positions 1-6 to execute the sequences.  
1. Write down the order for each of the sequences required for all  
of the six functions (not programmed with single commands).  
2. Turn the bank 2 dip switch on; bank 1, 3, and 4 off.  
3. Push PGM (program lamp goes on).  
4. Using the wire attached to the 590-00 +12VDC, touch and  
hold the other end of the wire to the 590-00 upper + row  
terminal 1. While holding the wire in place, press the remote  
control button of the first function while the remote is about  
2-4" from the 590-00 internal infrared sensor. The 590-00  
PROGRAM lamp will flicker while storing the IR signal.  
When the IR signal is stored, the confirm lamp comes on.  
Release the remote control button and release the wire to the  
upper row terminal. The IR signal is now stored in the 590-00  
bank 2 terminal 1.  
5. Hold the end of the wire to the 590-00 upper + row terminal  
2. While holding the wire in place, press the remote control  
button of the second function while it is about 2-4 inches from  
the 590-00 internal infrared sensor. The 590-00 PROGRAM  
lamp will flicker while storing the information. When the  
information is stored, the confirm lamp will come on. Release  
the remote control button and release the wire to the upper  
row terminal. The IR signal is now stored in the 590-00 bank 2  
terminal 2.  
In certain commercial applications a microphone paging override  
is required. Model MR171 paging and override module takes a  
balanced or unbalanced mic, (with defeatable phantom power) or  
a line level input and when activated overrides all inputs (even if  
some or all zones are in standby) and pages at a preset volume in  
all zones.  
A variety of door chime and telephone paging, door entry and  
front door camera modules are being developed. Check our web  
site for more information.  
TheMVP44aincludesa12VDCtriggeroutputtocontrolandpower  
variousitemswhentheMVP44aispoweredup.WhentheMVP44a  
agoesintostandbythetriggeroutputends.It'smaximumoutputis  
60mA.  
An innovative IR connection system is also included to turn on and  
off the various source components as well as four separate  
commands. A Xantech 590-00 controller is required for this  
purpose. The Xantech 590-00 is a an IR sequence generator. When  
itreceivescommandsfromtheMVP44aitgeneratesanIRcommand  
orsequenceofupto10commands.  
TheoncommandisautomaticallygeneratedwhentheMVP44agoes  
outofstandbyandintopowerup.Theoffcommandisautomatically  
generatedwhentheMVP44agoesfrompowerontostandby.These  
sequencesaregenerallyusedtoturnonandoffthesourceequipment.  
6. Continue this procedure until all of the required sequence  
commands have been learned by the 590-00. If more than 16  
IR signals have to be learned, fill up bank 2 with the first 16  
IR signals, then turn the bank 2 dip switch off, and the bank 3  
switch on. Continue with bank 3 position 1, 2 etc. Use bank 4  
positions 1, 2, etc., if required and bank 1 positions 7-16.  
Toactivatethefourcommands,whenthesystemispoweredup,  
press the MR60 keypad button FNC then quickly press one of the  
four source buttons on the top of the MR60 keypad. This will  
initiateapulseattheMVP44aFUNCTIONoutput,thatinturn  
generatesanIRcommandthatispumpedbackintotheMVP44aIR  
emitter port 1 and out to the various emitters connected to ports  
2-3-4, that will initiate the command to the source component.  
Note: When storing an IR signal command sequence, it is most  
reliable if commands to a component are timed as far apart as  
4
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
gather all the source remotes (with batteries inserted) near the 590-  
00. Screw one end of a temporary wire to the 590-00 terminal  
marked +12VDC. Power up the 590-00 and the MVP44a.  
It is very important to use a top quality RJ45 8/8 crimper  
tool. We strongly suggest using a cat 5 / RJ45 electronic  
tester to verify the wire conductors.  
The 590-00 can learn up to 16 different commands on each of its  
four banks. If more than 10 different IR commands are being stored  
use bank 2, 3, and 4 to store the sequence commands and bank one  
positions 1-6 to execute the sequences.  
InstallingtheMVP44ashouldberelativelyeasy.Withabitof  
planning,theMVP44awillgivetroublefreeserviceforyears.  
1.Themostimportantconsiderationwheninstallingthe  
MVP44a is cooling. The MVP44a has a lot of power packed into a  
smallchassissize.Wheninstallingitinanequipmentstack,itshould  
be the top component. It needs at least 1-3/4" of space above the  
MVP44atoallowforadequatecooling.  
2.WheninstallingtheMVP44ainarackwesuggestaddinga  
1-3/4"blankaboveandbelowtheMVP44a.InmultipleMVP44a  
installations,planfora3-1/2"blank(double)betweeneachMVP44a  
and a 1-3/4" blank on the top and bottom. Amplifiers should  
always be the top components in a rack system.  
3.IfMVP44achannelsfrequentlyshutdownduetooverheating,  
either the output levels will have to go down or 8 ohm speakers  
installed. If 8 ohm speakers are installed on all channels and some  
channels still shut down, call the factory for advice.  
4.ConnecttheMVP44ainputstothesourcecomponentoutputswith  
goodquality,shortaspossibleRCAjackcables.Connecteach  
channelindividually.  
5. If source D is not being used we suggest you short both of them  
out with a RCA shorting jack. This will make the room speakers  
quieter in standby modes.  
6. ConnecttheMVP44aspeakeroutputstospeakersusinggood  
quality speaker wire. Minimum 16 gauge copper wire is  
recommended with 14 gauge minimum for runs over 30' (10m)  
Make sure the speakers in each room are connected in phase.  
Single IR Command Storing  
Start by pushing the RES (reset) button on the back of the  
590-00. If any of the six relay activations have a single command  
(not a sequence of commands), program the single command(s) first.  
For example if the jazz station tuner is on source C and you want to  
program the IR command "scan" (two or more news stations have  
been programmed in the news station tuner) into function C, program  
the 590-00 with this first.  
1. Make sure the bank 1 dip switch is on; bank 2, 3, and 4 off.  
2. Push PGM (program lamp goes on).  
3. Using the wire attached to the 590-00 +12VDC, touch and  
hold the other end of the wire to the 590-00 upper + row  
terminal 2. While holding the wire in place, push the tuner  
remote control button "scan" while it is about 2-4 inches from  
the 590-00 internal infrared sensor. The 590-00 PROGRAM  
lamp will flicker while storing the IR signal. When the IR signal  
is stored, the confirm lamp comes on. Release the remote  
control button and release the wire to the upper row terminal.  
The IR signal is now stored in the 590-00 bank 1 terminal 2.  
4. Store any other single commands in bank 1 positions 1 and 3-6.  
5. Push PGM (program lamp will go out).  
590-00 Sequence IR Command Storing  
ThesixMVP44apulseactivationscanactivateasequenceofupto10  
IR commands each. As an overview, the individual IR commands  
are first learned and stored in any of the 16 positions in the four  
banks (except bank 1 positions 1 through 6), then assembled in order  
Note:IdeallytheMVP44alikes6-8ohmloads.Connectingto  
4ohmloadswon'thurttheMVP44abutthosechannels  
connected to 4 ohm loads may occasionally shut down due to  
overloading. Never connect the MVP44a to 2 ohm loads.  
5
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Install MR60 keypads (or infrared receivers) in the rooms with  
the speakers. Cat 3 or cat 5 wire can be home run to the MVP44a or  
up to three rooms daisy chained on one wire.  
***Be sure to set the dip switch on the rear of the MR60***  
See the dip switch adjustment below. Connect all eight individual  
wires using RJ45 connectors. Four wire conductors are needed for  
each keypad (one unique, common: IR , ground and 12VDC).  
MVP44a Activation  
The 590-00 generates infrared command sequences when a  
momentarypulsefromanyofthesixMVP44afunctionoutputsare  
activated.SourceAisusuallyreservedforCDuse.WhentheMVP44a  
ispoweredupsomeonepushingaMR60SourcebuttonorRB8  
remotesource,thepoweron(TON)pulseisactivated.  
SomeexamplestounderstandwhenMVP44apulsesareactivated  
andthe590-00macrosequenciesareinitiatedarelistedbelow:  
Note: None of the functions below work when any MR60 leds are  
blinking to indicate MUTE activated.  
1 2 3 4  
MR60  
MR60 Dip Switch  
Adjustment  
Use either RJ45  
connector as they  
are in parallel  
Pulse O/P  
Activates when:  
Example IR sequence:  
Power On  
(TON)  
Any MR60 or RB8 source  
key is pushed when all  
MR60 leds are off.  
FNC then Source A (CD)  
key pushed when system's on CDrandom  
Sequence power (on)  
command to all  
sourcecomponents  
CD skip, CD play or  
The rear of the MR60 is shown. Because one to three MR60's can  
be connected or daisy chained to the same cat 5 wire, the keypad  
position on the wire must be selected using the dip switch. The two  
MR60 RJ45 connectors are in parallel. Only one dip switch slider  
should be on and the other two off (#1 is shown on in this example).  
TheMR601-2-3dipswitchpositionscorrespondtoMVP44akeypad  
ports and speaker outputs A3 or B1-B2-B3.  
F A  
(source A  
CD player) and no MR60 blinking led's.  
F B  
(source B  
Jazz station) the system is on.  
F C FNC then Source C (Dish  
(source C AM or CD2) key pushed  
news tuner) when the system is on.  
F D  
(source D  
FNC then Source B (FM or CD skip to next disk  
AUX1) key pushed when  
***Even if the keypads are home run, the  
MR60 dip switch position has to be selected***  
If three keypads are daisy chained on one wire, select the MR60  
dip switch on the first MR60 to one, the second MR60 to two and  
the third MR60 to three. At the rear of the MVP44a, the RJ45  
connector from the three MR60 keypads can be connected any  
corresponding keypad Bank A3 or Bank B; port 1, 2 or 3. The  
corresponding speaker outputs will be the same number as selected  
on the MR60 keypad (example: the MR60 keypad with #2 dip on  
andconnectedtoMVP44akeypadbankBwillcontrolspeaker  
outputsB2RandB2L).  
Scan to next news  
stationprogrammed  
into news tuner  
FNC then Source D (AUX or Scan up one station  
AUX2)keypushedwhen  
sat dish#2) the system is on.  
Programming the 590-00  
IR functions do not have to be related to the source input. For  
example, if source A is a CD player and source B is a jazz tuner,  
function A could be a sequence of CD skip, CD play, and CD  
random. Function B could be CD Skip to next disk. After deciding  
and writing down the commands to be programmed for each of the  
six pulse activations (Function A, B, C, D, TON and TOFF),  
After installation, if the keypads are not working properly or not  
controlling at all, Check the MR60 dip switch settings, wiring  
layout and crimp as well as bank connections very carefully.  
6
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MVP44a to Xantech 590-00  
8. ConnecttheemitterstotheIREmitterportsontherearofthe  
MVP44a.Singleordualemitterscanbeused.IfaXantech590-00is  
beinginstalleddonotconnectemittersintheMVP44aIREmitter#1.  
9.WhenconnectingtwoormoreMVP44a'sinthesamehome,  
connecttheampstogetherusingstereo3.5mmplugs(allthreewiresare  
used) to the data plug on the rear of the MVP44a. The MVP44a's  
sharepoweronandoffdataaswellasinfraredsignals.  
The Xantech 590-00 is an infrared learning "remote" capable of  
convertingadrycontactclosureofeachoftheMVP44a'sfour  
functions, power-on (TON) and power-off (TOFF) to an IR  
macro sequence of up to 10 commands each.  
The 590-00 power supply is shipped with the 590-00. Power to  
the 590-00 should be on all the time (like a TV set) so the system  
IR commands can be sent as soon as any MR60 source buttons are  
pressed.  
The MVP44a source input RCA jacks are Y-corded  
together on all amps (source 1 left/right on amp 1  
to source 1 left/right on amp 2 etc.)  
Thefirsttimeinstallingandprogramminga590-00connectedtoa  
MVP44acanbeabittricky,sopleasefollowthesedirectionsclosely.  
10. Connect the AC power into an outlet that can supply at least six  
amps (700 watts) dedicated to each MVP44a.  
See the diagram on page 7.  
11. If a Xantech 590-00 is to be installed, the 590-00 needs to be  
wiredtotheMVP44aremovable8terminalconnectorandthe  
590-00 has to be programmed.  
Connectthe590-00rearpanel"O"and"G" terminalstothewirepair  
onthe3.5mmtowirepair(installersupplied).Connecttheblackwire  
withthestripetothe"O".Nextinsertthe3.5mmplugintotherearof  
theMVP44alabelled"IREmitters"and"1".  
With any type of single conductor wire connect the 590-00 bottom  
row - terminals 1, 2, 3, 4, 5, 6 and the -12VDC terminal.  
DO NOT connect any wires to the TRIG  
terminal on the MVP44a at this time.  
Now connect the MVP44a terminal FD to the 590-00 top row +  
terminal1.NextconnecttheMVP44aterminalFCtothe590-00top  
row + terminal 2.  
ContinuebyindividuallyconnectingtheMVP44aFB,FA,TOFFand  
TON to the 590-00 top row + terminal 3, 4, 5 and 6. If all of the  
sourceequipmenthasthesameIRcommandsforpower-onand  
power-off, move the wire on the 590-00 connected to terminal +5  
(on the + row) with the wire on the 590-00 terminal +6.  
Wiring the 590-00 to the MVP44a  
The wire/plug from the 590-00 IR emitter port 1 is a mono 3.5mm  
with the stripewire to the center/end of the 3.5mm connector. The  
rest of the wires can be almost any type.  
7
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note 1: Ideal speaker impedance is 6-8  
ohms. When using 4 ohm speakers,  
individual channels may occasionally  
shutdown due to protection system.  
MVP44a Rear Panel  
AC120V  
8 amps  
Outputs  
Outputs  
Source Inputs  
1
2
3
4
B1L+  
B1R+  
B2L+  
B2R+  
A3L+  
A3R+  
B1L-  
B1R-  
B2L-  
B2R-  
B3L+  
B3R+  
A3L-  
A3R-  
B3L-  
B3R-  
L
R
To Keypads  
Room B2Room B3  
Room A3 Room B1  
IREmitters  
4/in  
Room A3  
Room B1  
Room B2  
Room B3  
Data  
3
2
1
TrebleBassBalance TrebleBass Balance  
TrebleBass Balance TrebleBass Balance  
RJ45 plug function identification  
MR60 keypad functions  
comm  
2
ground  
Each RJ45 connector uses 4 wires from MR60  
to MVP44a for power, communications and IR.  
3 are common, 12VDC, GND (either) and IR.  
1 is uniqure 2-way comm (1, 2 or 3)  
ground  
not  
used  
Infrared receiver  
Comm1 goes to keypad slot A1 or B1  
Comm2 goes to keypad slot A2 or B2  
Comm3 goes to keypad slot A3 or B3  
Four source selection (this  
room and whole house) and  
four function selection buttons  
comm  
comm  
1
12 VDC  
infrared  
3
2
1
Three bar volume level  
indicators, blinks at min or max  
4
3
Mute button  
RJ45 plug color and pair wiring guide  
MUTE  
FNC  
Function select button  
comm 1 brown  
white/brown  
orange  
DN  
UP  
Volume up and down  
(this room only or whole  
house when FNC selected)  
OFF  
white/blue  
blue  
white/orange  
green  
not used white/green  
Shut off this room only or  
whole house off button  
(also blinks when remote  
control signal detected)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Refrigerator BAN 134 NF S User Manual
JAMO Switch AB 2 User Manual
JVC Camcorder UGZ HM400 User Manual
JVC Camcorder WR DV75U User Manual
JVC Speaker SP PW3000 User Manual
JVC Speaker System LVT0347 001A User Manual
JVC Stereo Receiver KD S670 User Manual
Kenmore Clothes Dryer 63932 User Manual
Kenwood Car Speaker KFC 136E User Manual
Klipsch Speaker RF 10 User Manual