®
Undercounter Dishwasher
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
KUDC03IT
KUDK03CT
KUDK03FT
KUDK03IT
KUDL03IT
KUDM03FT
KUDS03CT
KUDS03FT
KUDS03ST
KUDT03FT
KUDT03ST
KUDU03FT
KUDU03ST
KUDX03FT
KUDC03FV
KUDL03IV
KUDL03FV
KUDE03FT
24-7/8" (64.1 cm)
3/4" (1.9 cm)
insulation – may be
compressed (not used
on all models)
23-7/8"
(60.6 cm)
24-1/2"
(62.2 cm)
Electrical: 120-volt, 60-Hz, AC-only, 15- or
20-amp. fused electrical supply. Use copper wire
only. A time-delay fuse or circuit breaker and
separate circuit is recommended.
33-7/8"
(86 cm) min. with
wheels removed
Water: A hot water line with 20-120 psi
(138-862 kPa) water pressure. Water temperature
must be 120°F (49°C) at dishwasher. Use 3/8" O.D.
copper tubing with compression fitting or flexible
stainless steel braided fill line (1/2" minimum plastic
tubing is optional but not recommended). Use a 90°
elbow with 3/8" N.P.T. external pipe threads on one
end to connect to water inlet valve. Do not solder
within 6" (15.2 cm) from water inlet valve.
21" (53.3 cm)
Side view
Rear view
Drain: Use the new drain hose supplied with your
dishwasher. If this is not suitable, use a new drain
hose with a maximum length of 12 feet (3.7 m)
that meets all current AHAM/IAPMO test
CABINET OPENING DIMENSIONS
standards, is resistant to heat and detergent, and
fits the drain connector of the dishwasher. Must
have a high drain loop 20 inches (50.8 cm) above
the subfloor or floor. Connect drain hose to waste
tee or disposer inlet above drain trap in house
plumbing and 20 inches (50.8 cm) minimum
above the floor. An air gap must be used if the
drain hose is connected to house plumbing lower
than 20 inches (50.8 cm) above subfloor or floor.
Use 1/2" minimum I.D. drain line fittings.
24" (61 cm)**
All surfaces must be free
from intrusions
24" (61 cm)
min.
34"
(86.4 cm)
min.*
3-1/4"
(8.3 cm)
3-1/4"
(8.3 cm)
2"
2"
(5.1 cm)
(5.1 cm)
5-1/2"
3-1/2"
(14 cm)
(8.9 cm)
6" ***
(15.2 cm)
6" ***
(15.2 cm)
2"
9"
(5.1 cm)
10"
(25.4 cm)
(22.9 cm)
2-3/4" 3-1/4"
(7 cm) (8.3 cm)
3-1/4" 2-3/4"
(8.3 cm) (7 cm)
Cut holes in shaded area of cabinet walls or floor as specified below:
water line – 1/2" (1.3 cm)
drain line – 1-1/2" (3.8 cm)
direct wire – 3/4" (1.9 cm)
power supply cord – 1-1/2" (3.8 cm)
* Measured from the lowest point on the underside of countertop. May be
reduced to 33-7/8" (86 cm) by removing wheels from dishwasher.
** Minimum, measured from narrowest point of opening.
*** May be increased to 6-7/8" (17.5 cm) if height of opening is 34-1/2" (87.6 cm)
at its lowest point.
‡ Both sides
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10078153C
08-15-08
Download from Www.Somanuals.com. All Manuals Search And Download.
|